12
1
!Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
PLH10 Series (Safety Standard Recognized)
■ Features
1. High performance in high frequency range
2. Low profile in vertical core layout
3. Compact and light weight
4. Safety standards: EN60065
■ Applications
Suppressing radiation noise in switching power
supply and inverter (AC-AC converter)
17.5 max.
18 max.
13±0.5
(in mm)
10±0.5
16 max.
ø0.9 max.
3.5±1
(4)
[(1)]
(3)
[(2)]
(4)
[(3)]
(1)
[(2)]
Part Number Common Mode Inductance
(min.)
(µH)
Rated Current
(A) Rated Voltage
(V)
Insulation Resistance
(min.)
(M ohm)
PLH10AS7003R6P2 70 3.6 250 100
PLH10AS1112R6P2 110 2.6 250 100
PLH10AS1612R1P2 160 2.1 250 100
PLH10AS2211R5P2 220 1.5 250 100
PLH10AS2911R2P2 290 1.2 250 100
PLH10AS3711R0P2 370 1.0 250 100
Operating Temperature Range : -25°C to 60°C Winding Temperature Rise (at Rated Current) (max.) : 60K
■ Equivalent Circuit Diagram
(1)
(4)
(2)
(3)
N1
N2
N1 : N2 = 1 : 1
■ Insertion Loss Characteristics (Typical)
Insertion Loss (dB)
Frequency (MHz)
0.1 1.0 10 1000
0
10
20
30
40
50 100
PLH10AS1112R6P2
PLH10AS1612R1P2
PLH10AS2211R5P2
PLH10AS2911R2P2
PLH10AS3711R0P2
PLH10AS7003R6P2
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specifications before ordering.