www.tnb.com
In This Section…
Terminals
Overview .........................................................................C2–C5
Nylon Insulated Ring ........................................................C6–C8
Vinyl Insulated Ring................................................................C9
Non-Insulated Ring ......................................................C10–C11
Heavy-Duty Ring ..................................................................C12
High Temperature Non-Insulated..........................................C13
TEFZEL®Insulated Ring........................................................C13
Rectangular Rings................................................................C14
Flag Terminals ...........................................................................C15
Fork Terminals
Nylon Insulated Fork ............................................................C16
Vinyl Insulated Fork..............................................................C17
Non-Insulated Fork...............................................................C18
Locking Fork Terminals
Nylon Insulated Fork ............................................................C18
Vinyl Insulated Fork..............................................................C19
Heat-Shrinkable Fork ...........................................................C20
Non-Insulated Fork...............................................................C20
Pin Terminals .............................................................................C20
Insulated Ferrules..............................................................C21–C22
Non-Insulated Ferrules ..............................................................C23
Heat-Shrinkable Terminals, Splices, Disconnects...............C24–C25
Splice Connectors .............................................................C26–C27
Disconnects
Female (250 Series).............................................................C28
Piggy Back (250 Series) .......................................................C29
Female (187 Series).............................................................C29
Male (250 Series).................................................................C30
Male (187 Series and 110 Series) ........................................C30
250 Series Adapters and Coupler.........................................C30
Wristlock Disconnects..........................................................C31
Male (110 Series).................................................................C31
Pin Terminals/Vinyl Terminals (Mini-Pack) ..................................C31
Wire Joints – Nylon Insulated ....................................................C32
Installation Kits ..........................................................................C33
Application Tools
Sta-Kon Wire Stripping/Cutting Tool......................................C33
Plier Tools ............................................................................C34
Comfort Crimp .....................................................................C35
Rachet Hand Tools .......................................................C36–C38
Flag Type .............................................................................C38
TBM60RS Short Handle........................................................C38
Toggle Type..........................................................................C39
Shure-Stake®Auto Feed.......................................................C40
Battery-Powered Crimping ...................................................C41
Air Operated.........................................................................C42
Air Hydraulic ..................................................................C42–43
Electric Hydraulic Pump .......................................................C44
Twelve Ton Crimping......................................................C44–45
Installation Dies ...................................................................C45
Tool Charts ........................................................................C46–C48
Stud Size and Clearance Hole Chart.....................................C48
Wire Guide Tables..............................................................C49–C51
Military Cross Reference............................................................C52
Cross Reference for Packaging..................................................C54
Terminal Products
and Tools
Terminal Products and Tools
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-2
www.tnb.com
Terminal Products and Tools
Terminal Products and Tools
Selectively annealed
long barrel
Longer barrel design
Color-code Tefzel®,
Nylon or Vinyl Insulators
Brazed or overlapping
seams
Anti-rotational tongue
Hardened tongue
Complete wire and
stud size identification
Thomas & Betts developed the first tool-applied solderless terminals and
connectors more than 60 years ago in response to industry awareness of
the need for better performance of electrical systems.
Experience the Sta-Kon® advantage!
Overview — Why Sta-Kon® Terminals Are Better
Chamfered
Funnel Barrel
Entry
Deep Internal Serrations
After the insertion of a wire into the terminal’s barrel, a deep, serrated
interior ensures a large area of contact that lowers the resistance of a
connection. With the mechanical force of the tool, the wire strands cold
flow into the serrated interior. This guarantees electrical resistance lower
than the wire to which it is applied. This feature also prevents pullout from
vibration and mechanical strain. Deep internal serrations can be compared
to the effective holding power of a well-treaded tire on a wet highway.
Chamfered/Funneled Terminal Barrel Entry
This feature makes wire insertion faster and easier. Chamfering eliminates
wire strand “hang up” and departure upon insertion into the terminal’s
barrel. The loss of even a couple of wire strands can have negative results
on electrical efficiency and resistance to mechanical strain.
Sta-Kon®Long Barrel Design
If lowering electrical resistance, preventing wire pullout, eliminating a
“missed” crimp, and an insulator that stays on the barrel during installation
are your goals, then you must design a terminal with a long barrel. Most
competitive barrel lengths range from 20–50% shorter than Sta-Kon
®
terminals. The results are usually a stream of electrical failure, rework,
and added expense. This also provides the insulator with additional
surface area, holding tight to the barrel. Many competitive insulators
come off during crimping due to a limited barrel length.
Brazed or Overlapped Seam
A long barrel design is of little value unless it is one solid piece. That is why
Thomas & Betts brazes the seam on our vinyl insulated Sta-Kon
®
and
overlaps the seam on nylon insulated terminals. Many competitive terminals
have butted seams. This means increased chances for wirestrand loss, poor
resistance, wire pullout, and electrical failure. If the installer doesn’t position
the tool exactly on the correct spot on the barrel, there’s likely going to be
an improper termination. The butted seam can also fold due to tool-applied
pressure piercing the terminals insulation from the inside out. With a brazed
or overlapped seam, the installer can crimp anywhere along the barrel’s
surface. This provides up to 2.5 times the tensile strength of a butted seam
terminal, guaranteeing proper electrical flow, void free.
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
Strands enter as a
homogeneous group
and compact tightly
under compression due
to fully brazed seam
C-3
www.tnb.com
Terminal Products and Tools
Terminal Products and Tools
Superior terminals for superior connections!
Deep Internal Serrations
Flat bottom box
Electro-tin plating
Center reinforced spring
detent for minimum
insertion force
Compound Spring Rails
provide positive contact
after repeated insertions
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
Selective Annealing
Because of the mechanical strength of copper, an installer can experience
fatigue associated with repeated installations. For this reason, Thomas & Betts
puts its terminals through one more step called selective annealing. This
process leaves the barrel soft enough to crimp and form around the wire.
However, we “cold form” the tongue during the manufacturing process so
it remains strong. This is done so the tongue can withstand repeated bends
and bolt tightening strain common in most electrical installations. Many
competitors attempt to accomplish similar goals by removing valuable
material or using a softer copper, which has lower conductivity. This increases
electrical resistance as well as the odds for shorting and downtime.
Anti-Rotational Tongues
This is a unique feature to the Thomas & Betts ring tongue
terminal. This design prevents terminal shorting by keeping the
terminal secure in the terminal block. The installer can place a
greater number of terminals closer together without worry.
Proper Identification
We identify all terminals with Thomas & Betts initials, T & B. We also indicate
wire and stud sizes. These markings are clearly visible on the surface of the
tongue, taking any guesswork out of replacing or reordering additional parts.
Our superior bright plating also assists in visibility.
All Sta-Kon®Terminals Are Deburred
and Degreased
To ensure a Sta-Kon®terminal is properly plated and insulated, all our parts
are put through a process that cleans and smooths the terminal of any
manufacturing by-products — mainly grease, oils, and sharp edges. Many
competitive products do not put their product through such rigorous finishing.
FINISH SUFFIX SPEC.
Gold Plate GP MIL-G-45204 Type II, Grade B, C, D, Class O
Nickel Plate NP QQ-N-290 Class 2, Grade G
Plain Finish PF None
Silver Plate SP MIL-T-16366 Type I or II, 400° F, 204° C
Tin Plate TP MIL-T-10727 Type I
Platings/Finish
Electroplated-Tin is standard. All others require minimum order quantities
and are generally not stocked. Alternative platings are as follows: Gold, Silver,
Tin-Alloys, Nickel, etc.
The following finishes are available on most one-piece Sta-Kon®terminals:
Listing
Sta-Kon®Rings, Fork, and Locking Forks are tested
and listed to UL®486A, two-way splices to UL 486C,
disconnects to UL 310, and all applicable products
to CSA 22.2.
Overview — Why Sta-Kon® Terminals Are Better
C-4
www.tnb.com
Overview — Sta-Kon®Terminals
Terminal Products and Tools
Terminal Products and Tools
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
Sta-Kon®Ring, Fork, and Locking Fork
Complete line of installing tools engineered to match
tool with terminal
First to gain military approval for pressure
connections…many styles available for military
applications
Sta-Kon®products exceed test specification
requirements of military, UL®, and CSA
Tefzel®and Nylon Terminals provided with extra metal
sleeve to grip insulation
Vinyl insulated and bare Sta-Kon®terminals feature
brazed seam wire barrels that can be crimped at any
place on the barrel circumference
The tools and terminals you need!
Internal barrel serrations and long barrel provide for maximum tensile strength
Complete line of installing tools, engineered to match tool with terminal
Funnel entry insulators enable easier inserting of wire into barrel
Color-coded for easy installation
The Shure-Stake®
tools are matched
to terminals.
The Shure-Stake®mechanism prevents the dies
from releasing the terminal until the proper
compression has been completed. With this
method, an operator achieves a reliable crimp
every time. Thomas & Betts tooling techniques
correctly match tools, wire size, and terminal
to produce optimum mechanical and electrical
performance.
Sta-Kon®Disconnects
Common to Both Packages
Letter Adenotes 22–18 AWG wire range
Letter Bdenotes 16–14 AWG wire range
Letter Cdenotes 12–10 AWG wire range
Letter Rpreceding the above letters
indicates the terminal is insulated
No letter R… no insulation … no exception!
Distributor Packaged
Part numbers are very descriptive, indicating
insulation and type, stud size, tongue style, and
the largest maximum wire that can be put inside.
If the letter Rprecedes the number the part
is nylon insulated — RA18-6
If the letter Rfollows the number the part
is vinyl insulated — 14RB-8
EXAMPLE: 10RC-8F
C– Indicates 12–10 AWG
10RC – Vinyl Insulated
8– Indicates stud size
F– Indicates a fork tongue terminal
FL – Indicates a locking fork
EXAMPLE: 2RA18X
2– Indicates a 2-way or butt-style connector
X– Indicates expanded insulation
Tefzel®is a registered trademark of DuPont.
The Sta-Kon®Terminal Numbering System
(Distributor Package 100/50 or Bulk “O.E.M.” Packaged 1,000/500)
ERG-2001
C-5
www.tnb.com
Overview — Sta-Kon®Terminals
Terminal Products and Tools
Terminal Products and Tools
wire
stripping
length
terminal
orient tongu
as shown
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
The proper installation procedure
for the quality assured connection!
Recommended Tools
The Shure-Stake®mechanism prevents the dies from releasing the terminal
until the proper compression has been completed. With this method, an
operator achieves a reliable crimp every time. Thomas & Betts tooling
techniques correctly match tools, wire size, and terminal to produce optimum
mechanical and electrical performance.
Sta-Kon®Technical Data
TERMINALS & SPLICES UL®94
INSULATION RATING FLAMMABILITY VOLTAGE TEMPERATURE
Nylon V-2 600V** 105° C
Vinyl V-0 600V** 105° C
Tefzel®V-0 600V** 150° C
**1000V fixture or sign
Disconnects 300V 105° C
Non-Insulated 600V 150º C
ERG-2001
Stripped Wire Indentor
Nest
Terminal
Orient Tongue
as Shown
Stripping
Length
The proper installation of terminals, splices, and connectors is very important
to the efficient performance of an electrical system. The properly installed
connector will enable good conductivity through the termination. A poor
termination results in a high-resistance connection. A poor connector
installation may cause damage or failure of an entire system. Certain basic
requirements must be met to make a good termination.
1. Before the connector or terminal is installed on the
conductor, follow these recommended practices:
Strip the insulation carefully to avoid nicking or cutting
conductor strands
Strip the insulation to the proper length so the conductors
can be inserted fully into the connector barrel; the
wire/cable should be visible in the inspection hole of the
lug; the proper strip length can be found on page C-??.
2. Thomas & Betts wire strippers will help eliminate these
problems by properly gauging and measuring the depth
and length requirements for the conductor. See page C-??
for wire strippers.
The terminal must be properly installed.
Installation Procedure
1. Train the wires to eliminate fanning of strands.
2. Open handles fully.
3. Insert terminal in proper die nest and locate it as shown
above. When crimping a butt splice, position in proper die
nest with window facing indentor.
4. Close handles slightly to secure terminal. Do not deform
terminal.
5. Insert properly stripped wire into terminal.
6. Complete crimp by closing handles.
Ratchet type if installations are more than 20 per day
WT112M
Plier type if installations are fewer than 20 per day
12050
Power type if installations are more than 200 per day
C-6
www.tnb.com
Nylon Insulated Ring Terminals
Recommended for temperatures up to 221° F.
Terminal Products and Tools
Terminal Products and Tools
WT./LBS.
PKG. WIRE MAX. BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE 1,000 A B C M
RZ22-2** 100 26–22 .083 #2 1 .57 .14 .13 .49
RZ22-4** 100 26–22 .083 #4 1 .65 .21 .20 .54
RZ22-6** 100 26–22 .083 #6 1 .65 .21 .20 .54
RZ22-8** 100 26–22 .083 #8 1 .75 .25 .23 .62
RZ22-10** 100 26–22 .083 #10 1 .75 .25 .23 .62
RAX23* 1,000 26–24 .125 #2 3 .66 .14 .14 .59
RAX43* 1,000 26–24 .125 #4 3 .74 .20 .19 .64
RAX63* 1,000 26–24 .125 #6 3 .84 .25 .22 .72
RAX83* 1,000 26–24 .125 #8 3 .84 .25 .22 .72
RAX103* 1,000 26–24 .125 #10 3 .84 .25 .24 .72
RA18-4 100 22–16 .136 #4 2 .70 .23 .14 .59
RA323 1,000 22–16 .136 #4 2 .70 .23 .14 .59
RA333 1,000 22–16 .136 #6 2 .70 .23 .14 .59
RA18-6 100 22–16 .136 #6 2 .83 .26 .25 .71
RA853 1,000 22–16 .136 #6 2 .83 .26 .25 .71
RA18-8 100 22–16 .136 #8 3 .83 .26 .25 .71
RA833 1,000 22–16 .136 #8 3 .83 .26 .25 .71
RA863 1,000 22–16 .136 #8 3 .83 .26 .25 .71
RA18-10 100 22–16 .136 #10 2 .86 .31 .25 .71
RA873 1,000 22–16 .136 #10 2 .86 .31 .25 .71
RA18-14 100 22–16 .136 14" 3 1.07 .46 .31 .84
RA713 1,000 22–16 .136 14" 3 1.07 .46 .31 .84
RA18-516 100 22–16 .136 516" 3 1.07 .46 .31 .84
RA723 1,000 22–16 .136 516" 3 1.07 .46 .31 .84
RA18-38 100 22–16 .136 38" 3 1.17 .53 .35 .87
RA733 1,000 22–16 .136 38" 3 1.17 .53 .35 .87
RA18-12 100 22–16 .136 12" 3 1.27 .72 .50 .92
RA753 1,000 22–16 .136 12" 3 1.27 .72 .50 .92
RB14-4 100 18–14 .162 #4 212.72 .26 .14 .59
RB1323 1,000 18–14 .162 #4 212.72 .26 .14 .59
WT./LBS.
PKG. WIRE MAX. BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE 1,000 A B C M
RB14-6 100 18–14 .162 #6 3 .89 .31 .25 .71
RB853 1,000 18–14 .162 #6 3 .89 .31 .25 .71
RB1333 1,000 18–14 .162 #6 3 .74 .26 .14 .59
RB14-8 100 18–14 .162 #8 3 .89 .31 .25 .71
RB863 1,000 18–14 .162 #8 3 .89 .31 .25 .71
RB14-10 100 18–14 .162 #10 312.89 .31 .25 .71
RB873 1,000 18–14 .162 #10 312.89 .31 .25 .71
RB14-14 100 18–14 .162 14"3
121.08 .47 .31 .81
RB713 1,000 18–14 .162 14"3
121.08 .47 .31 .81
RB14-516 100 18–14 .162 516"3
121.08 .47 .31 .84
RB723 1,000 18–14 .162 516"3
121.08 .47 .31 .84
RB14-38 100 18–14 .162 38"3
121.17 .53 .35 .87
RB733 1,000 18–14 .162 38"3
121.17 .53 .35 .87
RB14-12 100 18–14 .162 12" 4 1.25 .72 .50 .90
RB753 1,000 18–14 .162 12" 4 1.25 .72 .50 .90
RC10-6 50 12–10 .210 #6 3 1.00 .37 .27 .81
RC333 500 12–10 .210 #6 3 1.00 .37 .27 .81
RC10-8 50 12–10 .210 #8 5 1.00 .37 .27 .81
RC863 500 12–10 .210 #8 5 1.00 .37 .27 .81
RC10-10 50 12–10 .210 #10 5 1.00 .37 .27 .81
RC363 500 12–10 .210 #10 5 1.00 .37 .27 .81
RC10-14 50 12–10 .210 14" 6 1.12 .53 .32 .86
RC713 500 12–10 .210 14" 6 1.12 .53 .32 .86
RC10-516 50 12–10 .210 516" 6 1.21 .53 .31 .94
RC703 500 12–10 .210 516" 6 1.21 .53 .31 .94
RC10-38 50 12–10 .210 38" 6 1.27 .59 .35 .98
RC733 500 12–10 .210 38" 6 1.27 .59 .35 .98
RC10-12 50 12–10 .210 12" 6 1.37 .72 .52 1.02
RC753 500 12–10 .210 12" 6 1.37 .72 .52 1.02
A
M
C
B
High dieletric-strength
nylon sleeves
Inner bronze insulation
grip sleeve lengthens
the flexing radius of the
conductor and eliminates
conductor creep
Nylon Insulated Ring Terminals — Insulation Grip
The nylon jacket is color-coded:
Color Code Wire Range
Yellow 26–22
Red 22–16
Blue 18–14
Yellow 12–10
Most standard bulk catalog
numbers can be put on mylar
tape for reel fed applications
(i.e., tool and application dies).
Add “M” to suffix for mylar tape
(ex. RA2573M) Bulk numbers
are 1,000 and 500 packages.
Installation tools: WT2000, WT112M, WT145C, ERG-2001, ERG-2003, WT145A.
Installation tool: WT1452 is for RZ series only.
* Not listed by UL®CSA ** CSA Listed only UL®Listed E9809
Stock thickness:
RZ & RAX stock thickness: .02
RA & RB stock thickness: .03
RC stock thickness: .04
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-7
www.tnb.com
Nylon Insulated Ring Terminals
Terminal Products and Tools
Terminal Products and Tools
A wider wire entry to accommodate heavy-wall insulation.
Nylon Insulated Ring Terminals — Expanded Insulation Grip
Ring terminals won’t fall free even if the mounting
screw loosens
Suffix “X” indicates an expanded insulation grip
Most standard bulk catalog numbers can be put on mylar tape
for reel fed applications (i.e., tool and application dies). Add
“M” to suffix for mylar tape (ex. RA2573M) Bulk numbers are
1,000 and 500 packages.
Stock thickness:
RB stock thickness: .03
RC stock thickness: .04
Installation tools: WT2000,
WT112M, WT145C, ERG-2001,
ERG-2003, WT145A
WT./LBS.
PKG. WIRE MAX. BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE 1,000 A B C M
RAS18-6X 100 22–18 .170 #6 2 1.23 .25 .27 1.10
RAS18-8X 100 22–18 .170 #8 3 1.26 .31 .27 1.10
RAS18-10X 100 22–18 .170 #10 2 1.26 .31 .27 1.10
RBS14-6X 100 16–14 .200 #6 3 1.23 .25 .27 1.10
RBS14-8X 100 16–14 .200 #8 3 1.23 .25 .27 1.10
RBS14-10X 100 16–14 .200 #10 3121.26 .31 .27 1.10
RCS10-6X 50 12–10 .250 #6 3 1.34 .31 .27 1.15
RCS10-8X 50 12–10 .250 #8 5 1.34 .37 .27 1.15
RCS10-10X 50 12–10 .250 #10 5 1.34 .37 .27 1.15
RCS10-14X 50 12–10 .250 14" 6 1.34 .49 .32 1.15
UL®Listed E9809
NOTE: Not available on mylar tape.
Heat-shrinkable polyolefin and an internally coated sealant offer more insulated support.
A fully sealed connection is achieved upon completed
installation to protect the joint against the degrading effects
of galvanic action, corrosion, and environmental exposure
Heat-Shrinkable Ring Terminals —
Expanded Insulation Support
A
M
C
B
WT./LBS.
PKG. WIRE MAX. BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE 1,000 A B C M
RB14-4X 100 18–14 .190 #4 4 .80 .26 .14 .67
RB1324 1,000 18–14 .190 #4 4 .80 .26 .14 .67
RB14-6X 100 18–14 .190 #6 4 .95 .31 .25 .79
RB854 1,000 18–14 .190 #6 4 .95 .31 .25 .79
RB14-8X 100 18–14 .190 #8 5 .95 .31 .25 .79
RB864 1,000 18–14 .190 #8 5 .95 .31 .25 .79
RB14-10X 100 18–14 .190 #10 5 .95 .31 .25 .79
RB874 1,000 18–14 .190 #10 5 .95 .31 .25 .79
RB14-14X 100 18–14 .190 14" 6 1.16 .47 .31 .92
RB714 1,000 18–14 .190 14" 6 1.16 .47 .31 .92
RB14-516X 100 18–14 .190 516" 6 1.16 .47 .31 .92
RB724 1,000 18–14 .190 516" 6 1.16 .47 .31 .92
RB14-38X 100 18–14 .190 38" 6 1.25 .53 .42 .95
RB734 1,000 18–14 .190 38" 6 1.25 .53 .42 .95
WT./LBS.
PKG. WIRE MAX. BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE 1000 A B C M
RC10-6X 50 12–10 .250 #6 5 1.10 .37 .27 .91
RC334 500 12–10 .250 #6 5 1.10 .37 .27 .91
RC10-8X 50 12–10 .250 #8 5 1.10 .37 .27 .91
RC864 500 12–10 .250 #8 5 1.10 .37 .27 .91
RC10-10X 50 12–10 .250 #10 5 1.10 .37 .27 .91
RC364 500 12–10 .250 #10 5 1.10 .37 .27 .91
RC10-14X 50 12–10 .250 14" 6 1.22 .53 .32 .96
RC714 500 12–10 .250 14" 6 1.22 .53 .32 .96
RC10-516X 50 12–10 .250 516" 6 1.32 .53 .31 1.05
RC704 500 12–10 .250 516" 6 1.32 .53 .31 1.05
RC10-38X 50 12–10 .250 38" 6 1.38 .59 .48 1.09
RC734 500 12–10 .250 38" 6 1.38 .59 .48 1.09
RC10-12X 50 12–10 .250 12" 6 1.48 .72 .52 1.13
UL®Listed E9809
Stock thickness:
RAS & RBS stock thickness: .03
RCS stock thickness: .04
Installation tool: WT1255
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
A
M
C
B
C-8
www.tnb.com
Nylon-Insulated Ring Terminals
Nylon construction offers insulation from electrical dangers.
Terminal Products and Tools
Terminal Products and Tools
RD: .04
RE: .04
RF: .04
RG: .05*
RH: .05
RJ: .06
RK: .06
RL: .07
RM: .07
*Brazed Seam, Lollipop-Style Tongue.
Stock Thickness:
WT./LBS.
PKG. WIRE MAX. BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE 1,000 A B C M
RD167 200 8 .340 #8 12 1.48 .42 .28 1.29
RD8-10 25 8 .340 #10 12 1.48 .42 .28 1.29
RD367 200 8 .340 #10 12 1.48 .42 .28 1.29
RD8-14 25 8 .340 14" 12 1.54 .46 .36 1.32
RD717 200 8 .340 14" 12 1.54 .46 .36 1.32
RD8-516 25 8 .340 516" 12 1.63 .57 .36 1.35
RD727 200 8 .340 516" 12 1.63 .57 .36 1.35
RD8-38 25 8 .340 38" 12 1.63 .57 .36 1.35
RD737 200 8 .340 38" 12 1.63 .57 .36 1.35
RD8-12 25 8 .310 12" 12 1.79 .82 .55 1.39
RD757* 200 8 .310 12" 12 1.79 .82 .55 1.39
RD10161 200 8AN .270 #8 12 1.40 .41 .24 1.20
RD10361 200 8AN .270 #10 12 1.40 .41 .24 1.20
RD10711 200 8AN .270 14" 12 1.45 .45 .34 1.22
RD10721 200 8AN .270 516" 12 1.53 .56 .34 1.25
RD10731 200 8AN .270 38" 12 1.53 .56 .34 1.25
RE6-10 20 6 .420 #10 16 1.65 .49 .28 1.40
RE267 200 6 .420 #10 16 1.65 .49 .28 1.40
RE6-14 20 6 .420 14" 16 1.65 .49 .28 1.40
RE717 200 6 .420 14" 16 1.65 .49 .28 1.40
RE6-516 20 6 .420 516" 16 1.76 .61 .34 1.47
RE727 200 6 .420 516" 16 1.76 .61 .34 1.47
RE6-38 20 6 .420 38" 16 1.76 .61 .34 1.47
RE737 200 6 .420 38" 16 1.76 .61 .34 1.47
RE6-12 20 6 .395 12" 16 1.83 .82 .55 1.43
RE757* 200 6 .395 12" 16 1.83 .82 .55 1.43
RE10261 200 6AN .315 #10 16 1.55 .49 .24 1.31
RE10711 200 6AN .315 14" 16 1.55 .49 .27 1.31
RE10721 200 6AN .315 516" 16 1.70 .60 .34 1.40
RE10731 200 6AN .315 38" 16 1.70 .60 .34 1.40
RF4-10 15 4 .510 #10 21 1.76 .56 .36 1.49
RF267 200 4 .510 #10 21 1.76 .56 .36 1.49
RF4-14 15 4 .510 14" 21 1.76 .56 .36 1.49
RF717 200 4 .510 14" 21 1.76 .56 .36 1.49
RF4-516 15 4 .510 516" 21 1.84 .62 .35 1.53
RF727 200 4 .510 516" 21 1.84 .62 .35 1.53
RF4-38 15 4 .510 38" 23 1.84 .62 .35 1.53
RF737 200 4 .510 38" 23 1.84 .62 .35 1.53
RF757* 200 4 .500 12" 23 1.90 .82 .55 1.49
RF10261 200 4AN .380 #10 26 1.78 .55 .30 1.51
RF10711 200 4AN .380 14" 26 1.78 .55 .30 1.51
RF10721 200 4AN .380 516" 26 1.80 .62 .34 1.49
WT./LBS.
PKG. WIRE MAX. BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE 1,000 A B C M
RF10731 200 4AN .380 38" 26 1.80 .62 .34 1.49
RG2-10 10 2 .588 #10 42 2.15 .69 .40 1.83
RG267 100 2 .588 #10 42 2.15 .69 .40 1.83
RG2-14 10 2 .588 14" 42 2.15 .69 .40 1.83
RG717 100 2 .588 14" 42 2.15 .69 .40 1.83
RG2-516 10 2 .588 516" 42 2.15 .69 .40 1.83
RG727 100 2 .588 516" 42 2.15 .69 .40 1.83
RG2-38 10 2 .588 38" 42 2.15 .69 .40 1.83
RG737 100 2 .588 38" 42 2.15 .69 .40 1.83
RG2-12 10 2 .588 12" 42 2.35 .80 .49 1.93
RG757 100 2 .588 12" 42 2.35 .80 .49 1.93
RG9711 100 1AN 453 14" 48 2.07 .69 .40 1.74
RG9731 100 1AN .453 38" 48 2.07 .69 .40 1.74
RG9751 100 1AN .453 12" 48 2.26 .80 .49 1.84
RH9711 100 1AN .500 14" 54 2.14 .77 .44 1.81
RH9731 100 1AN .500 38" 54 2.14 .77 .44 1.81
RH9751 100 1AN .500 12" 54 2.34 .77 .54 1.90
RJ9711 100 1/0AN .550 14" 80 2.35 .83 .46 1.97
RJ9731 100 1/0AN .550 38" 80 2.35 .83 .46 1.97
RJ9751 100 1/0AN .550 12" 80 2.49 .89 .55 2.04
RH717 100 1/0 .629 14" 80 2.14 .77 .43 1.81
RH727 100 1/0 .629 516" 80 2.14 .77 .43 1.81
RH737 100 1/0 .629 38" 80 2.14 .77 .43 1.81
RH757 100 1/0 .629 12" 80 2.34 .77 .54 1.90
RK9731 100 2/0AN .610 38" 70 2.52 .93 .55 2.14
RK9751 100 2/0AN .610 12" 70 2.60 .93 .55 2.15
RJ717 100 2/0 .675 14" 80 2.34 .83 .46 1.96
RJ727 100 2/0 .675 516" 80 2.34 .83 .46 1.96
RJ737 100 2/0 .675 38" 80 2.34 .83 .46 1.96
RJ757 100 2/0 .675 12" 80 2.48 .89 .54 2.03
RL9731 100 3/0AN .680 38" 120 2.83 1.04 .57 2.36
RL9751 100 3/0AN .680 12" 120 2.83 1.04 .57 2.36
RK717 100 3/0 .765 14" 84 2.60 .93 .54 2.21
RK727 100 3/0 .765 516" 84 2.60 .93 .54 2.21
RK737 100 3/0 .765 38" 84 2.60 .93 .54 2.21
RM9731 100 4/0AN .750 38" 160 3.00 1.13 .66 2.51
RM9751 100 4/0AN .750 12" 160 3.00 1.13 .66 2.51
RL737 100 4/0 .785 38" 130 2.83 1.04 .57 2.35
RL757 100 4/0 .785 12" 130 2.83 1.04 .57 2.35
RM737 100 250MCM .868 38" 130 3.00 1.13 .65 2.51
RM747 100 250MCM .868 716" 130 3.00 1.13 .65 2.51
RM757 100 250MCM .868 12" 130 3.00 1.13 .65 2.51
Nylon-Insulated Ring Terminals
A wide variety of wire ranges to choose from to suit the right application
Installation Tools: TBM6/TBM6S, ERG-2007,
(RD & RE except Brazed Seam)
AN – Aircraft Wire. UL Listed E9809.
NOTE: Not available on Mylar Tape.
A
M
C
B
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-9
www.tnb.com
Vinyl-Insulated Ring Terminals
Terminal Products and Tools
Terminal Products and Tools
A
M
C
B
A wider wire entry for heavy-wall insulation.
Ring terminals won’t fall free even
if the mounting screw loosens
Suffix X indicates an expanded
insulation support
Most standard bulk catalog numbers can be put on mylar tape
for reel-fed applications (i.e., tool and application dies).
Add “M” to suffix for mylar tape (ex. RA2573M). Bulk numbers
are 1,000 and 500 packages.
Stock thickness:
RA & RB: .03
RC: .04
Vinyl-Insulated Ring Terminals —
Expanded Insulation Support
PKG. WIRE MAX. BOLT WT./LBS. DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE PER 1,000 A B C M
18RA-6X 100 22–16 .170 #6 3 .97 .31 .27 .81
18RA-8X 100 22–16 .170 #8 3 .97 .31 .27 .81
RA867-170 1,000 22–16 .170 #8 3 .97 .31 .27 .81
18RA-10X 100 22–16 .170 #10 3 .97 .31 .27 .81
RA877-170 1,000 22–16 .170 #10 3 .97 .31 .27 .81
18RA-14X 100 22–16 .170 14" 4 1.13 .50 .37 .88
RA727-170 1,000 22–16 .170 516" 4 1.13 .50 .37 .88
14RB-4X 100 18–14 .200 #4 3 .94 .25 .27 .81
14RB-6X 100 18–14 .200 #6 3 .97 .31 .27 .81
RB857-200 1,000 18–14 .200 #6 3 .97 .31 .27 .81
14RB-8X 100 18–14 .200 #8 3 .97 .31 .27 .81
RB867-200 1,000 18–14 .200 #8 3 .97 .31 .27 .81
14RB-10X 100 18–14 .200 #10 3 .97 .31 .27 .81
RB877-200 1,000 18–14 .200 #10 3 .97 .31 .27 .81
14RB-14X 100 18–14 .200 14" 4 1.14 .50 .38 .89
RB717-200 1,000 18–14 .200 14" 4 1.14 .50 .38 .89
14RB-516X 100 18–14 .200 516" 4 1.15 .50 .38 .89
14RB-38X 100 18–14 .200 38" 4 1.16 .54 .35 .91
10RC-6X 50 12–10 .250 #6 5 1.06 .31 .27 .90
RC337-250 500 12–10 .250 #6 5 1.06 .31 .27 .90
10RC-8X 50 12–10 .250 #8 5 1.06 .31 .27 .90
RC777-250 500 12–10 .250 #8 5 1.06 .31 .27 .90
10RC-10X 50 12–10 .250 #10 5 1.06 .31 .27 .90
RC367-250 500 12–10 .250 #10 5 1.06 .31 .27 .90
10RC-14X 50 12–10 .250 14" 6 1.16 .50 .27 .90
RC717-250 500 12–10 .250 14" 6 1.16 .50 .27 .90
10RC-516X 50 12–10 .250 516" 6 1.17 .50 .37 .92
10RC-38X 50 12–10 .250 38" 6 1.29 .59 .44 .99
RC737-250 500 12–10 .250 38" 6 1.29 .59 .44 .99
UL Listed E9809
Installation Tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
A
M
C
B
Extra-length PVC sleeve offers extra protection.
Brazed seam barrel is serrated to
obtain high pull-out value
Made of high-conductivity
electrolytic copper, electro-tin plated
Most standard bulk catalog numbers can be put on mylar tape
for reel-fed applications (i.e., tool and application dies).
Add “M” to suffix for mylar tape (ex. RA2573M). Bulk numbers
are 1,000 and 500 packages.
Stock thickness:
RA & RB: .03
RC: .04
Vinyl-Insulated Ring Terminals — Insulation Grip
PKG. WIRE MAX. BOLT WT./LBS. DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE PER 1,000 A B C M
18RA-4 100 22–16 .150 #4 3 .97 .31 .27 .81
RA77 1,000 22–16 .150 #4 3 .97 .31 .27 .81
18RA-6 100 22–16 .150 #6 3 .94 .25 .27 .81
RA857 1,000 22–16 .150 #6 3 .94 .25 .27 .81
18RA-8 100 22–16 .150 #8 3 .97 .31 .27 .81
RA867 1,000 22–16 .150 #8 3 .97 .31 .27 .81
18RA-10 100 22–16 .150 #10 3 .97 .31 .27 .81
RA877 1,000 22–16 .150 #10 3 .97 .31 .27 .81
18RA-14 100 22–16 .150 14" 4 1.13 .50 .37 .88
RA717 1,000 22–16 .150 14" 4 1.13 .50 .37 .88
18RA-516 100 22–16 .150 516" 4 1.13 .50 .37 .88
RA727 1,000 22–16 .150 516" 4 1.13 .50 .37 .88
18RA-38 100 22–16 .150 38" 4 1.24 .54 .37 .91
RA737 1,000 22–16 .150 38" 4 1.24 .54 .37 .91
14RB-4 100 18–14 .170 #4 3 .94 .25 .27 .81
RB1327 1,000 18–14 .170 #4 3 .94 .25 .27 .81
14RB-6 100 18–14 .170 #6 3 .97 .31 .27 .81
RB857 1,000 18–14 .170 #6 3 .97 .31 .27 .81
14RB-8 100 18–14 .170 #8 3 .97 .31 .27 .81
RB867 1,000 18–14 .170 #8 3 .97 .31 .27 .81
14RB-10 100 18–14 .170 #10 3 .97 .31 .27 .81
RB877 1,000 18–14 .170 #10 3 .97 .31 .27 .81
14RB-14 100 18–14 .170 14" 4 1.14 .50 .38 .89
RB717 1,000 18–14 .170 14" 4 1.14 .50 .38 .89
14RB-516 100 18–14 .170 516" 4 1.15 .50 .38 .89
RB727 1,000 18–14 .170 516" 4 1.15 .50 .38 .89
14RB-38 100 18–14 .170 38" 4 1.16 .54 .38 .91
RB-737 1,000 18–14 .170 38" 4 1.16 .54 .38 .91
10RC-6 50 12–10 .210 #6 5 1.06 .31 .27 .90
RC337 500 12–10 .210 #6 5 1.06 .31 .27 .90
10RC-8 50 12–10 .210 #8 5 1.06 .31 .27 .90
RC777 500 12–10 .210 #8 5 1.06 .31 .27 .90
10RC-10 50 12–10 .210 #10 5 1.06 .31 .27 .90
RC367 500 12–10 .210 #10 5 1.06 .31 .27 .90
10RC-14 50 12–10 .210 14" 6 1.16 .50 .27 .90
RC717 500 12–10 .210 14" 6 1.16 .50 .27 .90
10RC-516 50 12–10 .210 516" 6 1.17 .50 .37 .92
RC707 500 12–10 .210 516" 6 1.17 .50 .37 .92
10RC-38 50 12–10 .210 38" 6 1.29 .59 .44 .99
RC737 500 12–10 .210 38" 6 1.29 .59 .44 .99
UL Listed E9809
Installation Tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003
Insulation material is
color-coded:
Color Code Wire Range
Red 22-16
Blue 18-14
Yellow 12-10
C-10
www.tnb.com
Insulated and Non-Insulated Ring Terminals
Terminal Products and Tools
Terminal Products and Tools
Most standard bulk catalog numbers
can be put on Mylar Tape for reel-
fed applications (i.e., 12050 tool and
applicaton dies). Please put the
suffix “M” for Mylar Tape RA2573M.
Stock Thickness:
A & B = .03
BC = .05
C = .04
A
M
C
B
Constructed of electrolytic copper for high conductivity!
Can be installed with crimping tools having a single
indentor or double indentor (recommended for solid wire)
Serrated barrel increases grip on wire
Wire range identification on the tongue of each terminal
Two wire ranges available
Vinyl-Insulated Ring Terminals
Non-Insulated Ring
Stock Thickness: .04
Vinyl construction offers protection from
frayed and dangerous wires.
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
CAT. PKG. WIRE BOLT WT./LBS. DIMENSIONS
NO. QTY. RANGE HOLE PER 1,000 A B C M
A18-4 100 22–16 #4 2 .75 .31 .27 .59
A18-6 100 22–16 #6 2 .72 .25 .27 .59
A85 1,000 22–16 #6 2 .72 .25 .27 .59
A18-8 100 22–16 #8 2 .75 .31 .27 .59
A86 1,000 22–16 #8 2 .75 .31 .27 .59
A18-10 100 22–16 #10 2 .75 .31 .27 .59
A87 1,000 22–16 #10 2 .75 .31 .27 .59
A18-14 100 22–16 14" 3 .92 .50 .37 .67
A71 1,000 22–16 14" 3 .92 .50 .37 .67
A18-516 100 22–16 516" 3 .92 .50 .37 .67
A72 1,000 22–16 516" 3 .92 .50 .37 .67
A18-38 100 22–16 38" 3 .99 .54 .35 .67
A73 1,000 22–16 38" 3 .99 .54 .35 .67
A18-12 100 22–16 12" 3 1.06 .72 .38 .70
A75 1,000 22–16 12" 3 1.06 .72 .38 .70
B14-4 100 18–14 #4 2 .72 .25 .27 .59
B132 1,000 18–14 #4 2 .72 .25 .27 .59
B14-6 100 18–14 #6 2 .72 .25 .27 .59
B133 1,000 18–14 #6 2 .72 .25 .27 .59
B14-8 100 18–14 #8 3 .75 .31 .27 .59
B86 1,000 18–14 #8 3 .75 .31 .27 .59
B14-10 100 18–14 #10 3 .75 .31 .27 .59
B87 1,000 18–14 #10 3 .75 .31 .27 .59
B14-14 100 18–14 14" 6 .93 .50 .38 .68
B71 1,000 18–14 14" 6 .93 .50 .38 .68
B14-516 100 18–14 516" 6 .93 .50 .38 .68
B72 1,000 18–14 516" 6 .93 .50 .38 .68
B14-38 100 18–14 38" 6 .96 .54 .35 .68
B73 1,000 18–14 38" 6 .96 .54 .35 .68
B14-12 100 18–14 12" 6 1.06 .72 .38 .70
B75 1,000 18–14 12" 6 1.06 .72 .38 .70
B85 1,000 18–14 #6 6 .75 .31 .27 .59
B134 1,000 18–14 #8 6 .72 .25 .27 .59
BC14-6 50
Heavy Duty 16–14
#6 4 .81 .25 .29 .68
BC85 500
Use C Tooling
#6 4 .81 .25 .29 .68
BC14-8 50
Heavy Duty 16–14
#8 4 .87 .39 .29 .68
BC86 500
Use C Tooling
#8 4 .87 .39 .29 .68
BC14-10 50
Heavy Duty 16–14
#10 5 .87 .39 .29 .68
BC87 500
Use C Tooling
#10 5 .87 .39 .29 .68
BC14-14 50
Heavy Duty 16–14
14" 5 .93 .51 .29 .68
BC71 500
Use C Tooling
14" 5 .93 .51 .29 .68
BC14-516 50
Heavy Duty 16–14
516" 6 1.04 .54 .38 .77
BC72 500
Use C Tooling
516" 6 1.04 .54 .38 .77
BC14-38 50
Heavy Duty 16–14
38" 6 1.09 .63 .38 .77
BC79 500
Use C Tooling
38" 6 1.09 .63 .38 .77
BC14-12 50
Heavy Duty 16–14
12" 6 1.32 .76 .54 .94
BC75 500
Use C Tooling
12" 6 1.32 .76 .54 .94
C10-6 50 12–10 #6 4 .82 .31 .27 .66
C33 500 12–10 #6 4 .82 .31 .27 .66
C10-8 50 12–10 #8 5 .82 .31 .27 .66
C77 500 12–10 #8 5 .82 .31 .27 .66
C10-10 50 12–10 #10 5 .85 .38 .27 .66
C26 500 12–10 #10 5 .85 .38 .27 .66
C36 1,000 12–10 #10 7 .82 .31 .27 .66
C10-14 50 12–10 14" 7 .91 .50 .27 .66
C71 500 12–10 14" 7 .91 .50 .27 .66
C10-516 50 12–10 516" 8 .98 .50 .38 .73
C70 500 12–10 516" 8 .98 .50 .38 .73
C72 1,000 12–10 516" 7 1.10 .59 .45 .80
C10-38 50 12–10 38" 7 1.10 .59 .45 .80
C73 500 12–10 38" 7 1.10 .59 .45 .80
C10-12 50 12–10 12" 7 1.21 .72 .38 .84
C75 500 12–10 12" 7 1.21 .72 .38 .84
UL®Listed E9809
Installing tools: WT111M, WT112M, WT110M, ERG-2002, WT2000
A
M
C
B
MAX.
STUD INS. WIRE DIMENSIONS
CAT. NO. SIZE DIA. RANGE A B C M
Code Wire AWG
RDV167 #8 .340 8 1.48 .42 .28 1.17
RDV367 #10 .340 8 1.48 .42 .28 1.17
RDV717 14" .340 8 1.54 .46 .36 1.20
RDV727 516" .340 8 1.63 .57 .36 1.23
RDV737 38" .340 8 1.63 .57 .36 1.23
RDV757*12" .310 8 1.79 .82 .55 1.27
REV267 #10 .420 6 1.65 .45 .28 1.23
REV717 14" .420 6 1.65 .49 .28 1.23
REV727 516" .420 6 1.76 .61 .34 1.30
REV737 38" .420 6 1.76 .61 .34 1.30
REV757*12" .395 6 1.83 .82 .55 1.26
*Brazed Seam, Lollipop-Style Tongue
Installation Tools: ERG-2007 (RD & RE except Brazed Seam), TBN6/65
NOTE: Not available on mylar tape.
C-11
www.tnb.com
Non-Insulated Ring Terminals
Terminal Products and Tools
Terminal Products and Tools
Select the configuration you need!
Non-Insulated Ring — Tubular
Can be installed with crimping tools having a single
indentor or double indentor (recommended for solid wire)
Serrated barrel increases grip on wire
Wire range identification on the tongue of each terminal
Stock Thickness:
G & H = .05
J & K = .06
L & M = .07
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
A
M
C
B
Can be installed with crimping tools having
a single indentor or double indentor
(recommended for solid wire)
Constructed of electrolytic copper for high conductivity
Wire range identification on the tongue of each terminal
Non-Insulated Ring — Brazed Seam
Stock Thickness:
D & E = .06
F = .07
D10, E10, F10 = .04
D975 & F975 = .04
Serrated barrel increases grip on wire!
CAT. PKG. WIRE BOLT WT./LBS. DIMENSIONS
NO. QTY. RANGE HOLE PER 1,000 A B C M
D26 200 8 #8 16 1.13 .48 .36 .90
D8-10 25 8 #10 16 1.13 .48 .36 .90
D36 200 8 #10 16 1.13 .48 .36 .90
D8-14 25 8 14" 14 1.13 .48 .36 .90
D71 200 8 14" 14 1.13 .48 .36 .90
D8-516 25 8 516" 16 1.32 .59 .49 1.03
D72 200 8 516" 16 1.32 .59 .49 1.03
D8-38 25 8 38" 14 1.32 .59 .49 1.03
D73 200 8 38" 14 1.32 .59 .49 1.03
D8-12 25 8 12" 14 1.49 .82 .55 1.09
D75 200 8 12" 14 1.49 .82 .55 1.09
E6-10 20 6 #10 17 1.13 .48 .36 .90
E26 200 6 #10 17 1.13 .48 .36 .90
E6-14 20 6 14" 20 1.13 .48 .36 .90
E71 200 6 14" 20 1.13 .48 .36 .90
E6-516 20 6 516" 20 1.32 .60 .49 1.03
E72 200 6 516" 20 1.32 .60 .49 1.03
E6-38 20 6 38" 20 1.32 .60 .49 1.03
E73 200 6 38" 20 1.32 .60 .49 1.03
E6-12 20 6 12" 20 1.49 .82 .55 1.08
E75 200 6 12" 20 1.49 .82 .55 1.08
F4-10 20 4 #10 24 1.16 .48 .36 .93
F26 200 4 #10 24 1.16 .48 .36 .93
F4-14 20 4 14" 25 1.16 .48 .36 .93
F71 200 4 14" 25 1.16 .48 .36 .93
F4-516 20 4 516" 25 1.35 .60 .49 1.06
F72 200 4 516" 25 1.35 .60 .49 1.06
F4-38 20 4 38" 25 1.35 .60 .49 1.06
F73 200 4 38" 25 1.35 .60 .49 1.06
F4-12 20 4 12" 25 1.52 .82 .55 1.11
F75 200 4 12" 25 1.52 .82 .55 1.11
Installing tools: WT115A D, E, F, and G,
TBM6/TBM6S, WT3185
NOTE: Not available on Mylar Tape.
Installing dies: 11802 INDENTOR
(D-E-F-G), D-11803-NEST, E-11805-NEST,
F-11806-NEST (all ordered separately)
CAT. PKG. WIRE BOLT WT./LBS. DIMENSIONS
NO. QTY. RANGE HOLE PER 1,000 A B C M
D10161 200 8 #8 12 1.15 .41 .28 .95
D10361 200 8 #10 12 1.15 .41 .28 .95
D10711 200 8 14" 12 1.20 .45 .36 .97
D10721 200 8 516" 12 1.28 .56 .36 1.00
D10731 200 8 38" 12 1.28 .56 .36 1.00
D975 200 8 12" 12 1.46 .83 .49 1.06
E10261 200 6 #10 14 1.26 .49 .24 1.02
E10711 200 6 14" 14 1.26 .49 .27 .99
E10721 200 6 516" 14 1.38 .60 .34 1.04
E10731 200 6 38" 14 1.38 .60 .34 1.04
F10261 100 4 #10 20 1.37 .55 .30 1.07
F10711 100 4 14" 20 1.37 .55 .30 1.07
F10721 100 4 516" 20 1.42 .62 .34 1.08
F10731 100 4 38" 20 1.42 .62 .34 1.08
F975 200 4 12" 20 1.49 .83 .45 1.10
G926 100 2 #10 40 1.59 .69 .40 1.26
G2-14 10 2 14" 50 1.59 .69 .40 1.26
G971 100 2 14" 40 1.59 .69 .40 1.26
G2-516 10 2 516" 50 1.59 .69 .40 1.26
G972 100 2 516" 40 1.59 .69 .40 1.26
G2-38 10 2 38" 50 1.59 .69 .40 1.26
G973 100 2 38" 40 1.59 .69 .40 1.26
G2-12 10 2 12" 50 1.79 .80 .49 1.36
G975 100 2 12" 40 1.79 .80 .49 1.36
H10-14 10 1/0 14" 50 1.65 .77 .43 1.32
H971 100 1AN-1/0 14" 50 1.65 .77 .43 1.32
H972 100 1AN-1/0 516" 50 1.65 .77 .43 1.32
H973 100 1AN-1/0 38" 50 1.65 .77 .43 1.32
H975 100 1AN-1/0 12" 50 1.85 .77 .54 1.41
J971 50 1/0AN-2/0 14" 60 1.94 .84 .48 1.53
J972 50 1/0AN-2/0 516" 60 1.94 .84 .48 1.53
J20-38 10 2/0 38" 70 1.84 .83 .46 1.46
J973 50 1/0AN-2/0 38" 60 1.99 .84 .53 1.58
J974 50 1/0AN-2/0 716" 60 1.99 .89 .51 1.56
J975 50 1/0AN-2/0 12" 60 1.99 .89 .51 1.56
K971 50 2/0AN-3/0 14" 76 2.08 .93 .54 1.69
K972 50 2/0AN-3/0 516" 76 2.08 .93 .54 1.69
K30-38 5 3/0 38" 82 2.08 .93 .54 1.69
K973 50 2/0AN-3/0 38" 76 2.08 .93 .54 1.69
K974 50 2/0AN-3/0 716" 76 2.08 .93 .54 1.70
K975 50 2/0AN-3/0 12" 76 2.08 .93 .54 1.70
L972 50 3/0AN-4/0 516" 100 2.25 1.04 .57 1.77
L40-38 5 4/0 38" 100 2.25 1.04 .57 1.77
L973 50 3/0AN-4/0 38" 92 2.25 1.04 .57 1.77
L974 50 3/0AN-4/0 716" 92 2.25 1.04 .57 1.77
L975 50 3/0AN-4/0 12" 92 2.25 1.04 .57 1.77
M972 50
4/0AN-250MCM
516" 112 2.28 1.12 .62 1.90
M250-38 5 250MCM 38" 135 2.40 1.12 .65 1.91
M973 50
4/0AN-250MCM
38" 112 2.40 1.12 .65 1.91
M974 50
4/0AN-250MCM
716" 112 2.40 1.12 .65 1.91
M975 50
4/0AN-250MCM
12" 112 2.40 1.12 .65 1.91
AN – Aircraft Wire
Installing tools: ERG-2005, ERG 2008, TBM6/TBM6S, WT3185
NOTE: Not available on Mylar Tape.
C-12
www.tnb.com
Heavy-Duty Ring Terminals
Terminal Products and Tools
Terminal Products and Tools
Most standard bulk catalog numbers can be put on Mylar Tape
for reel-fed applications (i.e., 12050 tool and application dies).
See pages C?? – C??.
Please put the suffix “M” for Mylar Tape RA2573M.
(Bulk number 1,000 and 500 packages.)
A
M
C
B
Stud Size Marked
In This Area
A
M
C
B
Stud Size Marked
In This Area
Nylon or Vinyl Insulated
Non-Insulated
Strong enough for tough applications!
The heavy-duty terminal solution!
WT./LBS.
CAT. PKG. WIRE MAX. BOLT PER DIMENSIONS
NO. QTY. RANGE INS. HOLE 1,000 A B C M
RBC14-6 50 16–14 Heavy Duty .210 #6 .98 .25 .29 .85
RBC853 500 Use RC Tooling .210 #6 .98 .25 .29 .85
RBC14-8 50 16–14 Heavy Duty .210 #8 1.04 .39 .29 .85
RBC863 500 Use RC Tooling .210 #8 1.04 .39 .29 .85
RBC14-10 50 16–14 Heavy Duty .210 #10 1.04 .39 .29 .85
RBC873 500 Use RC Tooling .210 #10 1.04 .39 .29 .85
RBC14-14 50 16–14 Heavy Duty .210 14" 1.10 .51 .29 .85
RBC713 500 Use RC Tooling .210 14" 1.10 .51 .29 .85
RBC14-516 50 16–14 Heavy Duty .210 516" 1.21 .54 .38 .94
RBC723 500 Use RC Tooling .210 516" 1.21 .54 .38 .94
RBC14-38 50 16–14 Heavy Duty .210 38" 1.26 .63 .38 .94
RBC793 500 Use RC Tooling .210 38" 1.26 .63 .38 .94
RBC14-12 50 16–14 Heavy Duty .210 12" 1.49 .76 .54 1.11
RBC753 500 Use RC Tooling .210 12" 1.49 .76 .54 1.11
14RBC-6 50 16–14 Heavy Duty .210 #6 5 1.06 .25 .29 .93
RBC857 500 Use RC Tooling .210 #6 5 1.06 .25 .29 .93
14RBC-8 50 16–14 Heavy Duty .210 #8 5 1.13 .39 .29 .93
RBC867 500 Use RC Tooling .210 #8 5 1.13 .39 .29 .93
14RBC-10 50 16–14 Heavy Duty .210 #10 5 1.13 .39 .29 .93
RBC877 500 Use RC Tooling .210 #10 5 1.13 .39 .29 .93
14RBC-14 50 16–14 Heavy Duty .210 14" 6 1.19 .51 .29 .93
RBC717 500 Use RC Tooling .210 14" 6 1.19 .51 .29 .93
14RBC-516 50 16–14 Heavy Duty .210 516" 6 1.29 .54 .38 1.03
RBC727 500 Use RC Tooling .210 516" 6 1.29 .54 .38 1.03
14RBC-38 50 16–14 Heavy Duty .210 38" 6 1.34 .63 .38 1.03
RBC797 500 Use RC Tooling .210 38" 6 1.34 .63 .38 1.03
14RBC-12 50 16–14 Heavy Duty .210 12" 6 1.57 .76 .54 1.19
RB757 500 Use RC Tooling .210 12" 6 1.57 .76 .54 1.19
WT2000, WT145C, and power tools as recommended crimp in the 12-10 nest (yellow).
WT./LBS.
CAT. PKG. WIRE MAX. BOLT PER DIMENSIONS
NO. QTY. RANGE INS. HOLE 1,000 A B C M
BC14-6 50 16–14 Heavy Duty #6 .81 .25 .29 .68
BC85 500 Use RC Tooling #6 .81 .25 .29 .68
BC14-8 50 16–14 Heavy Duty #8 .87 .39 .29 .68
BC86 500 Use RC Tooling #8 .87 .39 .29 .68
BC14-10 50 16–14 Heavy Duty #10 .87 .39 .29 .68
BC87 500 Use RC Tooling #10 .87 .39 .29 .68
BC14-14 50 16–14 Heavy Duty 14" .93 .51 .29 .68
BC71 500 Use RC Tooling 14" .93 .51 .29 .68
BC14-516 50 16–14 Heavy Duty 516" 1.04 .54 .38 .77
BC72 500 Use RC Tooling 516" 1.04 .54 .38 .77
BC14-38 50 16–14 Heavy Duty 38" 1.09 .63 .38 .77
BC79 500 Use RC Tooling 38" 1.09 .63 .38 .77
BC14-12 50 16–14 Heavy Duty 12" 1.32 .76 .54 .94
BC75 500 Use RC Tooling 12" 1.32 .76 .54 .94
WT111M, WT2000, and power tools as recommended, crimp in the 12–10 nest.
Nylon & Vinyl #16–14 AWG — Heavy Duty
Non-Insulated
#16–14 AWG
Heavy Duty
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
Material — Copper .050 thick
Finish — Electro tin-plate
Wire Range — #16–14
Color Code — Green vinyl or nylon insulator
. . . . . . . . . . Specifications . . . . . . . . .
C-13
www.tnb.com
High-Temperature Non-Insulated & Tefzel ® Insulated Ring Terminals
Terminal Products and Tools
Terminal Products and Tools
B
M
C
A
A
M
C
B
Stock Thickness:
RAT & RBT = .03
RCT = .04
Package Quantities:
RAT & RBT = 1,000 pieces
RCT = 500 pieces
Most standard bulk catalog numbers can be put on
Mylar Tape for reel-fed applications (i.e., 12050 tool and
application dies). See pages K??- K??.
Please put the suffix “M” for Mylar Tape RA2573M. (Bulk
number 1,000 and 500 packages.)
Stock Thickness:
24-22 ga. = .032
20-18 ga. = .032
16-14 ga. = .040
12-10 ga. = .040
UL®94V-0 rated!
MAX.
CAT. STUD INS. WIRE DIMENSIONS
NO. SIZE DIA. RANGE A B C M
Series RAT — For UL 94V-O Flammability Rating/High Temperature and Chemical Resistance
RAT853 #6 .140 22–18 .81 .25 .25 .69
RAT863 #8 .140 22–18 .84 .31 .25 .69
RAT873 #10 .140 22–18 .84 .31 .25 .69
RAT713 14" .140 22–18 1.07 .46 .31 .84
Series RBT
RBT853 #6 .170 16–14 .84 .31 .25 .69
RBT863 #8 .170 16–14 .84 .31 .25 .69
RBT873 #10 .170 16–14 .84 .31 .25 .69
RBT713 14" .170 16–14 1.08 .46 .31 .81
Series RCT
RCT333 #6 .210 12–10 1.00 .37 .27 .81
RCT863 #8 .210 12–10 1.00 .37 .27 .81
RCT363 #10 .210 12–10 1.00 .37 .27 .81
RCT713 14" .210 12–10 1.11 .52 .32 .85
RCT703 516" .210 12–10 1.23 .52 .31 .96
RCT733** 38" .210 12–10 1.29 .58 .35 1.00
** Not available on tape.
UL Listed E9809
Installing tool: WT145C, WT112M
Tefzel®is a registered trademark of DuPont.
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
Tefzel®Insulated Ring —
Insulation Grip
For easily installed, permanent terminations of solid, round, or stranded nichrome wires!
High-Temperature Non-Insulated Ring — 1,200° F Max.
WT./LBS.
CAT. PKG. WIRE BOLT PER DIMENSIONS
NO. QTY. RANGE HOLE 1,000 A B C M
NW21 1,000 24–22 #6 1.5 .59 .31 .28 .44
NW22 1,000 24–22 #8 1.5 .59 .31 .28 .44
NW23 1,000 24–22 #10 1.5 .59 .31 .28 .44
NW18-10 100 20–18 #10 2.5 .63 .31 .28 .38
NW52 1,000 20–18 #8 2.5 .63 .31 .28 .38
NW81 1,000 16–14 #6 2.5 .66 .31 .28 .51
NW14-8 100 16–14 #8 2.5 .66 .31 .28 .51
NW14-10 100 16–14 #10 2.5 .66 .31 .28 .51
NW83 1,000 16–14 #10 2.5 .66
NW14-12 100 16–14 #12* 2.5 .66 .31 .28 .51
NW84 1,000 16–14 #12* 2.5 .66
NW10-8 50 12–10 #8 3 .66 .31 .28 .51
NW10-10 50 12–10 #10 3 .66 .31 .28 .51
NW10-12 50 12–10 #12* 3 .66 .31 .28 .51
* #12 stud is approximate 14" stud.
Installing tool: WT1377
NOTE: Not available on Mylar Tape.
Terminals for
nichrome wire
NW Series
High temperature
non-insulated ring
terminals and splices
Designed for use with solid
or stranded resistance wires
as used in appliances such as
toasters, irons, and heaters
C-14
www.tnb.com
Nylon Insulated and Non-Insulated Rectangular Ring Terminals
Terminal Products and Tools
Terminal Products and Tools
A
M
C
B
Stock Thickness:
RA & RB = .03
RC = .04
NOTE:
22–18 ga. = 1-2 Navy
16–14 ga. = 212-4 Navy
12–10 ga. = 6-9 Navy
Most standard bulk catalog numbers can be put on Mylar Tape
for reel-fed applications (i.e., 12050 tool and application dies).
Please put the suffix “M” for Mylar Tape RA2573M. (Bulk
number 1,000 and 500 packages.)
A
M
C
B
The terminals you need!
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
BU-SHIPS
CAT.
STUD WIRE DIMENSIONS TONGUE
NO.
SIZE RANGE A B C M SHAPE
Series RA
RA486 #4 22–18 .796 .237 .237 .143 L86P-1
RA485 #4 22–18 1.015 .237 .404 .195 L85P-1
RA483 #5 22–18 .859 .277 .277 .143 L83P-1
RA484 #6 22–18 1.015 .237 .404 .195 L84P-1
RA481 #6 22–18 1.109 .302 .465 .227 L81P-1
RA482 #8 22–18 1.109 .302 .465 .227 L82P-1
RA480** #8 22–18 1.359 .390 .621 .310 L80P-1
Series RB
RB486 #4 16–14 .796 .237 .237 .143 L86P-2
RB485 #4 16–14 1.015 .237 .404 .195 L85P-2
RB483 #5 16–14 .859 .277 .277 .143 L83P-2
RB484 #6 16–14 1.015 .237 .404 .195 L84P-2
RB481 #6 16–14 1.109 .302 .465 .227 L81P-2
RB482 #8 16–14 1.109 .302 .465 .227 L82P-2
RB480** #8 16–14 1.359 .390 .621 .310 L80P-2
Series RC
RC486 #4 12–10 .984 .237 .237 .143 L86P-3
RC485 #4 12–10 1.187 .237 .404 .195 L85P-3
RC483 #5 12–10 1.046 .277 .277 .143 L83P-3
RC484 #6 12–10 1.203 .237 .404 .195 L84P-3
RC481 #6 12–10 1.281 .302 .465 .227 L81P-3
RC482 #8 12–10 1.281 .302 .465 .227 L82P-3
RC480** #8 12–10 1.531 .390 .621 .310 L80P-3
** Not available on tape.
NOTE: RA, RB, RC486 for use with BU-Ships terminal board types 26TB. RA, RB, RC485 for
use with 25TB and 27TB. RA, RB, RC483 for use with 8TB. RA, RB, RC484 for use with
10TB and 11TB. RA, RB, RC481 for use with 6TB, 7TB and 9TB. RA, RB, RC482 for use with
15TB. RA, RB, RC480 for use with 3TB, 4TB, 5TB, 16TB, 17TB and 18TB.
NOTE: When ordering terminals on tape, add the suffix “M” to the
catalog number, example: (RA250M).
UL®Listed E9809
Installing tools: ERG2001, WT145C
Nylon Insulated Rectangular Rings
Stock Thickness:
A & B = .03
C = .04
NOTE:
22–18 ga. = 1–2 Navy
16–14 ga. = 212–4 Navy
12–10 ga. = 6–9 Navy
Most standard bulk catalog numbers can be put on Mylar Tape
for reel-fed applications (i.e., 12050 tool and application dies).
Please put the suffix “M” for Mylar Tape RA2573M. (Bulk
number 1,000 and 500 packages.)
Select from a variety of configurations!
BU-SHIPS
CAT.
STUD WIRE DIMENSIONS TONGUE
NO.
SIZE RANGE A B C M SHAPE
Series A
A486 #4 22–18 .65 .237 .237 .143 L86
A485 #4 22–18 .87 .237 .404 .195 L85
A483 #5 22–18 .70 .277 .277 .143 L83
A484 #6 22–18 .87 .237 .404 .195 L84
A481 #6 22–18 .96 .302 .465 .227 L81
A482 #8 22–18 .96 .302 .465 .227 L82
A480** #8 22–18 1.21 .390 .621 .310 L80
Series B
B486 #4 16–14 .65 .237 .237 .143 L86
B485 #4 16–14 .87 .237 .404 .195 L85
B483 #5 16–14 .70 .277 .277 .143 L83
B484 #6 16–14 .87 .237 .404 .195 L84
B481 #6 16–14 .96 .302 .465 .227 L81
B482 #8 16–14 .96 .302 .465 .227 L82
B480** #8 16–14 1.21 .390 .621 .310 L80
Series C
C486 #4 12–10 .73 .237 .237 .143 L86
C485 #4 12–10 .90 .237 .404 .195 L85
C483 #5 12–10 .76 .277 .277 .143 L83
C484 #6 12–10 .94 .237 .404 .195 L84
C481 #6 12–10 1.03 .302 .465 .227 L81
C482 #8 12–10 1.03 .302 .465 .227 L82
C480** #8 12–10 1.27 .390 .621 .310 L80
** Not available on tape.
NOTE: A, B, C486 for use with Bu-Ships terminal board types 26TB. A, B. C485 for use with
25TB, 27TB. A, B, C483 for use with 8TB. A, B, C484 for use with 10TB and 11TB. A, B,
C481 for use with 6TB, 7TB and 9TB. A, B, C482 for use with 15TB. A, B, C480 for use with
3TB, 5TB, 16TB, 17TB and 18TB.
NOTE: When ordering terminals on tape, add the suffix “M” to the catalog number,
example: (RA250M).
UL Listed E9809
Installing tool: ERG 2002
Non-Insulated Rectangular Rings
C-15
www.tnb.com
Non-Insulated Flag Terminals
Terminal Products and Tools
Terminal Products and Tools
A
M
C
B
Stock Thickness:
AB = .03
C = .04
D = .06
E = .06
F = .07
G = .08
Flag terminals enable a 90º connection to the terminal
block without bending the wire!
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
Non-Insulated Flag WT./LBS.
CAT. PKG. WIRE BOLT PER DIMENSIONS
NO. QTY. RANGE HOLE 1,000 A B C M
AB14-6A 100 22–14 #6 212.55 .31 .22 .39
AB51 1,000 22–14 #6 212.55 .31 .22 .39
AB14-8A 100 22–14 #8 212.55 .31 .22 .39
AB52 1,000 22–14 #8 212.55 .31 .22 .39
AB14-10A 100 22–14 #10 212.55 .31 .22 .39
AB53 1,000 22–14 #10 212.55 .31 .22 .39
C51 1,000 12–10 #6 5 .66 .31 .25 .48
C10-8A 50 12–10 #8 5 .66 .31 .25 .48
C52 500 12–10 #8 5 .66 .31 .25 .48
C10-10A 50 12–10 #10 5 .66 .31 .25 .48
C53 500 12–10 #10 5 .66 .31 .25 .48
D236 1,000 9,8,7 #10 — .83 .50 .25 .59
D226 1,000 9,8,7 #10 — .88 .50 .29 .64
D271 1,000 9,8,7 14" — .92 .50 .33 .68
E226 1,000 6,5 #10 — .93 .50 .29 .69
E271 1,000 6,5 14" — .97 .50 .33 .73
E272 1,000 6,5 516" 1.05 .50 .41 .81
F226 1,000 4,3 #10 — 1.07 .56 .33 .80
F271 1,000 4,3 14" — 1.10 .63 .33 .80
F272 1,000 4,3 516" — 1.18 .63 .41 .88
F273 1,000 4,3 38" — 1.20 .63 .43 .90
G671 1,000 2 14" — 1.20 .63 .33 .89
G672 1,000 2 516" — 1.28 .63 .41 .97
G673 1,000 2 38" — 1.32 .63 .46 1.02
H672 —1
516" — 1.31 .63 .41 1.01
H673 —1
38" — 1.36 .63 .46 1.06
J672 —2
516" — 1.46 .75 .41 1.10
J673 —2
38" — 1.51 .75 .46 1.15
J675 —2
12" — 1.67 .75 .55 1.24
K672 —3
516" — 1.59 .81 .41 1.19
K673 —3
38" — 1.64 .81 .46 1.24
K675 —3
12" — 1.76 .81 .55 1.34
M673 —4
38" — 1.89 1.0 .46 1.43
M675 —4
12" — 1.99 1.0 .55 1.52
UL®Listed E9809
Installing tools: ERG-2004 (For AB and C Flag only.)
NOTE: Not available on Mylar Tape.
C-16
www.tnb.com
Nylon Insulated Fork Terminals
Nylon Insulated Fork —
Insulation Grip
Fork terminals with nylon insulation sleeves, recommended
for temperatures up to 105°C. Inner bronze insulation grip
sleeve lengthens flex radius of conductor and eliminates
conductor creep. Nylon jacket is color-coded
Stock thickness same as ring terminal of same size
Most standard bulk catalog numbers can be put on Mylar Tape for reel-fed
applications (i.e., 12050 tool and application dies).
Please put the suffix “M’’ for Mylar Tape RA2573M.
(Bulk number 1,000 and 500 packages.)
Withstands
temperatures
up to 105º C!
Nylon Insulated Fork
Flanged Tongue Insulation Grip
Suffix “S” indicates a flanged-tongue fork with turned up
tips for extra holding protection
Stock thickness same as ring terminal of same size
Most standard bulk catalog numbers can be put on Mylar Tape for reel-fed
applications (i.e., 12050 tool and application dies).
Please put the suffix “M” for Mylar Tape RA2573M.
(Bulk number 1,000 and 500 packages.)
Enables EASY
installation —
just loosen
the screw!
Terminal Products and Tools
Terminal Products and Tools
A
MC
B
WT./LBS.
PKG. WIRE MAX. BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE 1,000 A B C M
RA18-6F 100 22–16 .136 #6 3 .83 .25 .25 .71
RA1103 1,000 22–16 .136 #6 3 .83 .25 .25 .71
RA18-8F 100 22–16 .136 #8 3 .86 .31 .25 .71
RA1123 1,000 22–16 .136 #8 3 .86 .31 .25 .71
RA18-10F 100 22–16 .136 #10 3 .86 .31 .25 .71
RA1153 1,000 22–16 .136 #10 3 .86 .31 .25 .71
RA18-14F 100 22–16 .136 14" 4 .95 .44 .31 .70
RA1163 1,000 22–16 .136 14" 4 .95 .44 .31 .70
RB14-6F 100 18–14 .162 #6 312.87 .31 .25 .71
RB1113 1,000 18–14 .162 #6 312.87 .31 .25 .71
RB14-8F 100 18–14 .162 #8 312.87 .31 .25 .71
RB1123 1,000 18–14 .162 #8 312.87 .31 .25 .71
RB14-10F 100 18–14 .162 #10 4 .87 .38 .25 .71
RB1153 1,000 18–14 .162 #10 4 .87 .38 .25 .71
RB14-14F 100 18–14 .162 14" 4 .95 .44 .28 .74
RB1163 1,000 18–14 .162 14" 4 .95 .44 .28 .74
RB1103 1,000 18–14 .162 #6 6 .74 .28 .16 .60
RB1124 1,000 18–14 .190 #8 6 .95 .31 .25 .79
RB1154 1,000 18–14 .190 #10 6 .95 .31 .25 .79
RC10-6F 50 12–10 .210 #6 6 .97 .31 .27 .81
RC1113 500 12–10 .210 #6 6 .97 .31 .27 .81
RC10-8F 50 12–10 .210 #8 6 1.00 .37 .27 .81
RC1123 500 12–10 .210 #8 6 1.00 .37 .27 .81
RC10-10F 50 12–10 .210 #10 6 1.00 .37 .27 .81
RC1153 500 12–10 .210 #10 6 1.00 .37 .27 .81
RC10-14F 50 12–10 .210 14" 6 1.12 .50 .27 .86
RC1163 500 12–10 .210 14" 6 1.12 .50 .27 .86
RC1124 1,000 12–10 .250 #8 6 1.10 .37 .27 .91
RC1154 1,000 12–10 .250 #10 6 1.10 .37 .27 .91
UL®Listed E9809
Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT145A
WT./LBS.
PKG. WIRE MAX. BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE 1,000 A B C M
RA18-6FS 100 22–16 .136 #6 3 .75 .28 .16 .62
RA1203 1,000 22–16 .136 #6 3 .75 .28 .16 .62
RA18-8FS 100 22–16 .136 #8 3 .89 .31 .23 .65
RA1223 1,000 22–16 .136 #8 3 .89 .31 .23 .65
RA18-10FS 100 22–16 .136 #10 3 .93 .38 .26 .68
RA1253 1,000 22–16 .136 #10 3 .93 .38 .26 .68
RB14-6FS 100 18–14 .162 #6 4 .74 .28 .16 .60
RB1203 1,000 18–14 .162 #6 4 .74 .28 .16 .60
RB14-8FS 100 18–14 .162 #8 4 .89 .31 .23 .66
RB1223 1,000 18–14 .162 #8 4 .89 .31 .23 .66
RB14-10FS 100 18–14 .162 #10 4 .94 .38 .27 .69
RB1253 1,000 18–14 .162 #10 4 .94 .38 .27 .69
RB1204 1,000 18–14 .190 #6 4 .79 .28 .16 .67
RB1224 1,000 18–14 .190 #8 4 .94 .31 .23 .71
RC10-8FS 50 12–10 .210 #8 5 .97 .34 .23 .73
RC1223 500 12–10 .210 #8 5 .97 .34 .23 .73
RC10-10FS 50 12–10 .210 #10 5 1.00 .38 .26 .74
RC1253 500 12–10 .210 #10 5 1.00 .38 .26 .74
RC1224 1,000 12–10 .250 #8 5 1.08 .34 .23 .80
RC1254 1,000 12–10 .250 #10 5 1.12 .38 .26 .86
UL Listed E9809
Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT145A
A
MC
B
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-17
www.tnb.com
Vinyl Insulated Fork Terminals
Protects and
relieves stress
at the wire’s
flex point.
Terminal Products and Tools
Terminal Products and Tools
A
MC
B
Fork terminals enable easy installation because the
mounting screw does not have to be completely removed
Suffix “X” indicates an expanded insulation support,
meaning a wider wire entry to accommodate heavy
wall insulation
Stock thickness same as ring terminal of same size
A
MC
B
Vinyl Insulated Fork —
Insulation Support
These fork terminals have extra-long PVC insulation sleeve
for protection and stress relief at wire’s flex point
Brazed seam barrel is serrated for high pull-out value.
Terminal is high conductivity electrolytic copper, electro-tin
plated. Insulation is color-coded
Stock thickness same as ring terminal of same size
Most standard bulk catalog numbers can be put
on Mylar Tape for reel-fed applications (i.e., 12050
tool and application dies).
Wider wire entry
to accommodate
heavy wall
insulation!
Vinyl Insulation Fork —
Expanded Insulation Support
WT./LBS.
PKG. WIRE MAX. BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE 1,000 A B C M
18RA-6F 100 22–16 .150 #6 5 .94 .25 .27 .81
RA1167 1,000 22–16 .150 #6 5 .94 .25 .27 .81
18RA-8F 100 22–16 .150 #8 5 .97 .31 .27 .81
RA1147 1,000 22–16 .150 #8 5 .97 .31 .27 .81
18RA-10F 100 22–16 .150 #10 5 .97 .31 .27 .81
RA1157 1,000 22–16 .150 #10 5 .97 .31 .27 .81
14RB-6F 100 18–14 .170 #6 6 .97 .31 .27 .81
RB647 1,000 18–14 .170 #6 6 .97 .31 .27 .81
14RB-6FS 100 18–14 .170 #6 6 .89 .30 .25 .75
14RB-8F 100 18–14 .170 #8 6 .97 .31 .27 .81
RB657 1,000 18–14 .170 #8 6 .97 .31 .27 .81
14RB-10F 100 18–14 .170 #10 6 .97 .31 .27 .81
RB1157 1,000 18–14 .170 #10 6 .97 .31 .27 .81
14RB-14F 100 18–14 .170 14" 6 1.11 .44 .38 .89
RB1717 1,000 18–14 .170 14" 6 1.11 .44 .38 .89
10RC-6F 50 12–10 .210 #6 7 1.09 .38 .27 .90
RC1337 500 12–10 .210 #6 7 1.09 .38 .27 .90
10RC-8F 50 12–10 .210 #8 7 1.09 .38 .27 .90
RC1147 500 12–10 .210 #8 7 1.09 .38 .27 .90
10RC-10F 50 12–10 .210 #10 7 1.09 .38 .27 .90
RC1157 500 12–10 .210 #10 7 1.09 .38 .27 .90
10RC-14F 50 12–10 .210 14" 7 1.15 .50 .37 .90
RC1167 500 12–10 .210 14" 7 1.15 .50 .37 .90
UL®Listed E9809.
Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003
Please put the suffix “M” for Mylar Tape RA2573M. (Bulk number 1,000 and 500 packages.)
WT./LBS.
PKG. WIRE MAX. BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE 1,000 A B C M
18RA-6FX 100 22–16 .170 #6 5 .94 .25 .27 .81
RA1167-170 1,000 22–16 .170 #6 5 .94 .25 .27 .81
18RA-8FX 100 22–16 .170 #8 5 .97 .31 .27 .81
RA1147-170 1,000 22–16 .170 #8 5 .97 .31 .27 .81
18RA-10FX 100 22–16 .170 #10 5 .97 .31 .27 .81
RA1157-170 1,000 22–16 .170 #10 5 .97 .31 .27 .81
14RB-6FX 100 18–14 .200 #6 6 .97 .31 .27 .81
RB647-200 1,000 18–14 .200 #6 6 .97 .31 .27 .81
14RB-8FX 100 18–14 .200 #8 6 .97 .31 .27 .81
RB657-200 1,000 18–14 .200 #8 6 .97 .31 .27 .81
14RB-10FX 100 18–14 .200 #10 6 .97 .31 .27 .81
RB1157-200 1,000 18–14 .200 #10 6 .97 .31 .27 .81
10RC-8FX 50 12–10 .250 #8 7 1.11 .38 .27 .90
RC1147-250 500 12–10 .250 #8 7 1.11 .38 .27 .90
10RC-10FX 50 12–10 .250 #10 7 1.11 .38 .27 .90
RC1157-250 500 12–10 .250 #10 7 1.11 .38 .27 .90
10RC-14FX 50 12–10 .250 14" 7 1.17 .50 .37 .90
UL Listed E9809.
Installing tools: WT145C, WT2000, WT112M, ERG2001, ERG2003
Please put the suffix “M” for Mylar Tape RA2573M. (Bulk number 1,000 and 500 packages.)
Most standard bulk catalog numbers can be put
on Mylar Tape for reel-fed applications (i.e., 12050
tool and application dies).
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-18
www.tnb.com
Non-Insulated & Nylon Insulated Locking Fork Terminals
Non-Insulated Fork
Can be installed with crimping tools having a single
indentor or double indentor (recommended for solid wire)
Serrated barrel increases grip on wire
Wire range identification is stamped on the tongue
of each terminal
Stock thickness same as ring terminal of same size
Nylon Insulated Locking Fork —
Insulation Grip
Terminal Products and Tools
Terminal Products and Tools
A
MC
B
Most standard bulk catalog numbers can be put
on Mylar Tape for reel-fed applications (i.e., 12050
tool and application dies).
A
MC
B
Electrolytic copper offers high
conductivity.
Specially designed tongue enables it to go on like a fork
and stay on like a ring
Stock thickness same as ring terminal of same size
Most standard bulk catalog numbers can be
put on Mylar Tape for reel-fed applications
(i.e., 12050 tool and application dies).
Goes on like a
fork, stays on
like a ring!
WT./LBS.
PKG. WIRE MAX. BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE 1,000 A B C M
RA18-6FL 100 22–16 .136 #6 5 .86 .25 .25 .71
RA2213 1,000 22–16 .136 #6 5 .86 .25 .25 .71
RA18-8FL 100 22–16 .136 #8 5 .86 .29 .25 .71
RA2243 1,000 22–16 .136 #8 5 .86 .29 .25 .71
RA18-10FL 100 22–16 .136 #10 5 .86 .29 .25 .71
RA2253 1,000 22–16 .136 #10 5 .86 .29 .25 .71
RB14-6FL 100 18–14 .162 #6 6 .87 .25 .25 .71
RB2213 1,000 18–14 .162 #6 6 .87 .25 .25 .71
RB2214 1,000 18–14 .190 #6 6 .95 .25 .25 .79
RB14-8FL 100 18–14 .162 #8 6 .87 .29 .25 .71
RB2233 1,000 18–14 .162 #8 6 .87 .29 .25 .71
RB14-10FL 100 18–14 .162 #10 6 .87 .29 .25 .71
RB2253 1,000 18–14 .162 #10 6 .87 .29 .25 .71
RB2254 1,000 .190 #10 6 .95 .29 .25 .71
RC10-6FL 50 12–10 .210 #6 8 .97 .31 .27 .81
RC2203 500 12–10 .210 #6 8 .97 .31 .27 .81
RC2204 1,000 12–10 .250 #6 8 1.07 .31 .27 .91
RC10-8FL 50 12–10 .210 #8 8 1.00 .37 .27 .81
RC2213 500 12–10 .210 #8 8 1.00 .37 .27 .81
RC10-10FL 50 12–10 .210 #10 8 1.00 .37 .27 .81
RC2223 500 12–10 .210 #10 8 1.00 .37 .27 .81
RC2224 1,000 12–10 .250 #10 1.10 .37 .27 .91
RC10-14FL 50 12–10 .210 14" 8 1.12 .50 .32 .86
RC2233 500 12–10 .210 14" 8 1.12 .50 .32 .86
UL Listed E9809
Installing tools: ERG-2001, ERG-2003, WT145C, WT2000, WT112M, WT145A
Please put the suffix “M” for Mylar Tape RA2573M. (Bulk number 1,000 and 500 packages.)
WT./LBS.
PKG. WIRE BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE HOLE 1,000 A B C M
A18-6F 100 22–16 #6 4 .72 .25 .27 .59
A116 1,000 22–16 #6 4 .72 .25 .27 .59
A18-8F 100 22–16 #8 4 .75 .31 .27 .59
A114 1,000 22–16 #8 4 .75 .31 .27 .59
A18-10F 100 22–16 #10 4 .75 .31 .27 .59
A115 1,000 22–16 #10 4 .75 .31 .27 .59
B14-6F 100 18–14 #6 6 .75 .31 .27 .59
B64 1,000 18–14 #6 6 .75 .31 .27 .59
B19 1,000 18–14 #6 6 .66 .25 .13 .50
B14-8F 100 18–14 #8 6 .75 .31 .27 .59
B65 1,000 18–14 #8 6 .75 .31 .27 .59
B14-10F 100 18–14 #10 6 .75 .31 .27 .59
B115 1,000 18–14 #10 6 .75 .31 .27 .59
B14-14F 100 18–14 14" 6 .90 .44 .38 .68
C10-6F 50 12–10 #6 7 .77 .31 .27 .63
C133 500 12–10 #6 7 .77 .31 .27 .63
C10-8F 50 12–10 #8 7 .82 .38 .27 .63
C114 500 12–10 #8 7 .82 .38 .27 .63
C10-10F 50 12–10 #10 7 .82 .38 .27 .63
C115 500 12–10 #10 7 .82 .38 .27 .63
C10-14F 50 12–10 14" 7 .98 .50 .37 .73
C116 500 12–10 14" 7 .98 .50 .37 .73
UL®Listed E9809
Installing tools: WT111M, WT112M, WT110M, WT2000, ERG-2002
Please put the suffix “M” for Mylar Tape RA2573M. (Bulk number 1,000 and 500 packages.)
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-19
www.tnb.com
Vinyl Insulated Fork Terminals
Terminal Products and Tools
Terminal Products and Tools
A
MC
B
Stock thickness same as ring terminal
of same size
Most standard bulk catalog numbers can be
put on Mylar Tape for reel-fed applications
(i.e., 12050 tool and application dies).
A
MC
B
Most standard bulk catalog numbers
can be put on Mylar Tape for reel-fed
applications (i.e., 12050 tool and
application dies).
Vinyl Insulated Locking Fork—
Expanded Insulation Support
Stock thickness
same as ring
terminal of
same size!
WT./LBS.
PKG. WIRE MAX. BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE 1,000 A B C M
18RA-6FL 100 22–16 .150 #6 5 .97 .25 .25 .81
RA2217 1,000 22–16 .150 #6 5 .97 .25 .25 .81
RA2227 1,000 22–16 .155 #6 5 .97 .29 – .81
18RA-8FL 100 22–16 .150 #8 5 .97 .29 .25 .81
RA2247 1,000 22–16 .150 #8 5 .97 .29 .25 .81
18RA-10FL 100 22–16 .150 #10 5 .97 .29 .25 .81
RA2257 1,000 22–16 .150 #10 5 .97 .29 .25 .81
14RB-6FL 100 18–14 .170 #6 6 .97 .25 .27 .81
RB2207 1,000 18–14 .170 #6 6 .97 .25 .27 .81
RB2217 1,000 .170 #6 6 .97 .29 .27 .81
14RB-8FL 100 18–14 .170 #8 6 .97 .29 .27 .81
RB2237 1,000 18–14 .170 #8 6 .97 .29 .27 .81
14RB-10FL 100 18–14 .170 #10 6 .97 .29 .27 .81
RB2257 1,000 18–14 .170 #10 6 .97 .29 .27 .81
10RC-6FL 50 12–10 .220 #6 8 1.09 .31 .27 .90
RC2207 500 12–10 .220 #6 8 1.09 .31 .27 .90
10RC-8FL 50 12–10 .220 #8 8 1.09 .37 .27 .90
RC2217 500 12–10 .220 #8 8 1.09 .37 .27 .90
10RC-10FL 50 12–10 .220 #10 8 1.09 .37 .27 .90
RC2227 500 12–10 .220 #10 8 1.09 .37 .27 .90
10RC-14FL 50 12–10 .220 14" 8 1.09 .49 .27 .90
RC2237 500 12–10 .220 14" 8 1.09 .49 .27 .90
UL®Listed E9809.
Installing tools: ERG-2001, ERG-2003, WT145C, WT2000, WT112M
Please put the suffix “M” for Mylar Tape RA2573M. (Bulk number 1,000 and 500 packages.)
WT./LBS.
PKG. WIRE MAX. BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE 1,000 A B C M
18RA-6FLX 100 22–16 .170 #6 5 .97 .25 .25 .81
18RA-8FLX 100 22–16 .170 #8 5 .97 .29 .25 .81
18RA-10FLX 100 22–16 .170 #10 5 .97 .29 .25 .81
RA2257-170 1,000 22–16 .170 #10 5 .97 .29 .25 .81
14RB-6FLX 100 18–14 .200 #6 6 .97 .31 .27 .81
RB2207-200 1,000 18–14 .200 #6 6 .97 .31 .27 .81
RB2217-200 1,000 18–14 .200 #6 6 .97 .29 .27 .81
14RB-8FLX 100 18–14 .200 #8 6 .97 .31 .27 .81
RB2237-200 1,000 18–14 .200 #8 6 .97 .31 .27 .81
14RB-10FLX 100 18–14 .200 #10 6 .97 .31 .27 .81
RB2257-200 1,000 18–14 .200 #10 6 .97 .31 .27 .81
10RC-6FLX 50 12–10 .250 #6 8 1.07 .31 .27 .91
RC2207-250 500 12–10 .250 #6 8 1.07 .31 .27 .91
10RC-8FLX 50 12–10 .250 #8 8 1.10 .37 .27 .91
10RC-10FLX 50 12–10 .250 #10 8 1.10 .37 .27 .91
RC2227-250 500 12–10 .250 #10 8 1.10 .37 .27 .91
10RC-14FLX 50 12–10 .250 14" 8 1.22 .50 .32 .96
UL Listed E9809.
Installing tools: ERG-2001, ERG-2003, WT145C, WT2000, WT112M
Please put the suffix “M” for Mylar Tape RA2573M. (Bulk number 1,000 and 500 packages.)
Vinyl Insulated Locking Fork —
Insulation Support
Provides
expanded
insulation
support.
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-20
www.tnb.com
Locking Fork & Pin Terminals
UL®Listed
Expanded
insulation support
Terminal Products and Tools
Terminal Products and Tools
A
B
PKG. WIRE MAX. BOLT WT./LBS. DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE PER 1000 A B
RAS18-6FLX 100 22-18 .170 #6 5 1.350 .25
RAS18-8FLX 100 22-18 .170 #8 5 1.350 .29
RAS18-10FLX 100 22-18 .170 #10 5 1.350 .29
RBS14-6FLX 100 16-14 .200 #6 6 1.350 .25
RBS14-8FLX 100 16-14 .200 #8 6 1.350 .29
RBS14-10FLX 100 16-14 .200 #10 6 1.350 .29
RCS10-6FLX 50 12-10 .250 #6 8 1.350 .31
RCS10-8FLX 50 12-10 .250 #8 8 1.350 .37
RCS10-10FLX 50 12-10 .250 #10 8 1.350 .37
RCS10-14FLX 50 12-10 .250 1⁄4" 8 1.350 .49
UL Listed E9809
Installing tool: WT1255
NOTE: Heat-Shrinkable terminals not available on Mylar Tape.
Locking fork terminals for a secure, tight fit.
Heat-Shrinkable Locking
Fork Terminals — Expanded
Insulation Support
Terminals that do the job right!
Non-Insulated Locking
Fork Terminals
PKG. WIRE BOLT WT./LBS. DIMENSIONS
CAT. NO. QTY. RANGE HOLE PER 1000 A B C M
A18-6FL 100 22-16 #6 434.75 .25 .27 .59
A221 1,000 22-16 #6 434.75 .25 .27 .59
A18-8FL 100 22-16 #8 434.75 .29 .27 .59
A224 1,000 22-16 #8 434.75 .29 .27 .59
A18-10FL 100 22-16 #10 434.75 .29 .27 .59
A225 1,000 22-16 #10 434.75 .29 .27 .59
B14-6FL 100 18-14 #6 434.75 .25 .27 .59
B220 1,000 18-14 #6 434.75 .25 .27 .59
B14-8FL 100 18-14 #8 434.75 .29 .27 .59
B223 1,000 18-14 #8 434.75 .29 .27 .59
B14-10FL 100 18-14 #10 434.75 .29 .27 .59
B225 1,000 18-14 #10 434.75 .29 .27 .59
C10-6FL 50 12-10 #6 734.85 .31 .27 .66
C220 500 12-10 #6 734.85 .31 .27 .66
C10-8FL 50 12-10 #8 734.85 .37 .27 .66
C221 500 12-10 #8 734.85 .37 .27 .66
C10-10FL 50 12-10 #10 734.85 .37 .27 .66
C222 500 12-10 #10 734.85 .37 .27 .66
C10-14FL 50 12-10 1⁄4" 734.85 .49 .27 .66
UL Listed E9809
Installing tools: WT110M, WT111M, WT112M, WT2000, ERG-2002
Please put the suffix “M” for Mylar Tape RA2573M. (Bulk number 1,000 and 500 packages.)
PKG. WIRE D RECOMMENDED
CAT. NO. QTY. RANGE (DIA.) L TOOLS
Non-Insulated
A47PT 1000 22-18 .075 .63 WT111M
B47PT 1000 16-14 .075 .63 ERG-2002
C55PT 500 12-10 .110 .76
Vinyl
18RA-47PT 100 22-18 .075 .85 ERG-2003
RA47PT 1000 22-18 .075 .85
14RB-47PT 100 16-14 .075 .87
RB47PT 1000 16-14 .075 .87
10RC-55PT 50 12-10 .110 1.06
RC55PT 500 12-10 .106 1.06 ERG-2001
Nylon
RA18-47PT 100 22-18 .075 .85 ERG-2003
RA147PT 1000 22-18 .075 .85 WT2000
RB14-47PT 100 16-14 .075 .87
RB147PT 1000 16-14 .075 .87
RC10-55PT 50 12-10 .110 1.06
RC155PT 500 12-10 .106 1.06 ERG-2001
Most standard bulk catalog numbers can be put on Mylar Tape for reel-fed applications
(i.e., 12050 tool and application dies). See pages C??- C??.
Please put the suffix “M’’ for Mylar Tape RA2573M. (Bulk number 1,000 and 500 packages.)
Pin Terminals
Meets emerging global
standards, requiring wire-
to-metric style terminal
block installations be
terminated with a “pin”
style terminal
Available in vinyl insulated,
nylon insulated, and non-
insulated styles
All styles offered in 22
AWG to 10 AWG and
compatible with existing
Sta-Kon®tooling
Non-Insulated Vinyl/Nylon
Easily terminate stranded wire into
European/metric-style terminal blocks.
Stock thickness same
as ring terminal of same size
UL Listed
Most standard bulk catalog numbers can be put
on Mylar Tape for reel-fed applications (i.e., 12050
tool and application dies). See pages C??–C??.
A
MC
B
Voltage Rating: Vinyl – 300V Nylon – 300V
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-21
www.tnb.com
Terminal Products and Tools
Terminal Products and Tools
CONDUCTOR SECTION DIMENSIONS INCHES/MM INSTALLATION BAG CASE
CAT. NO. AWG MM2 COLOR A B ØC ØD E TOOLING PKG. QTY. PKG. QTY.
F4004 26 0.14 Gray .413/10.5 .236/6.0 .031/.80 .079/2.0 .010/.25 T3, ERG2 500 10,000
F4005 26 0.14 Gray .492/12.5 .315/8.0 .031/.80 .079/2.0 .010/.25 T3, ERG2 500 10,000
F4006 24 0.25 Yellow .413/10.5 .236/6.0 .031/.80 .079/2.0 .010/.25 T3, ERG2 500 10,000
F4007 24 0.25 Yellow .492/12.5 .315/8.0 .031/.80 .079/2.0 .010/.25 T3, ERG2 500 10,000
F4008 22 0.34 Purple .413/10.5 .236/6.0 .031/.80 .079/2.0 .010/.25 T3, ERG2 500 10,000
F4009 22 0.34 Purple .492/12.5 .315/8.0 .031/.80 .079/2.0 .010/.25 T3, ERG2 500 10,000
F2020 20 0.50 White .453/11.5 .236/6.0 .043/1.1 .098/2.5 .006/0.15 T1, T3 & ERG-2 500 5,000
F2021 20 0.50 White .531/13.5 .315/8.0 .043/1.1 .098/2.5 .006/0.15 T1, T3 & ERG-2 500 10,000
F2022 20 0.50 White .610/15.5 .394/10.0 .043/1.1 .098/2.5 .006/0.15 T1, T3 & ERG-2 500 5,000
F2023 18 0.75 Gray .472/12.0 .236/6.0 .051/1.3 .110/2.8 .006/0.15 T1, T3 & ERG-2 500 5,000
F2024 18 0.75 Gray .551/14.0 .315/8.0 .051/1.3 .110/2.8 .006/0.15 T1, T3 & ERG-2 500 10,000
F2025 18 0.75 Gray .630/16.0 .394/10.0 .051/1.3 .110/2.8 .006/0.15 T1, T3 & ERG-2 500 5,000
F2026 18 0.75 Gray .709/18.0 .472/12.0 .051/1.3 .110/2.8 .006/0.15 T1, T3 & ERG-2 500 5,000
F2027 18 0.75 Red .492/12.5 .236/6.0 .059/1.5 .118/3.0 .006/0.15 T1, T3 & ERG-2 500 5,000
F2028 18 0.75 Red .571/14.5 .315/8.0 .059/1.5 .118/3.0 .006/0.15 T1, T3 & ERG-2 500 10,000
F2029 18 0.75 Red .650/16.5 .394/10.0 .059/1.5 .118/3.0 .006/0.15 T1, T3 & ERG-2 500 5,000
F2030 18 0.75 Red .728/18.5 .472/12.0 .059/1.5 .118/3.0 .006/0.15 T1, T3 & ERG-2 500 5,000
F2031 16 1.50 Black .571/14.5 .315/8.0 .071/1.8 .134/3.4 .006/0.15 T1, T3 & ERG-2 500 10,000
F2032 16 1.50 Black .650/16.5 .394/10.0 .071/1.8 .134/3.4 .006/0.15 T1, T3 & ERG-2 500 5,000
F2033 16 1.50 Black .728/18.5 .472/12.0 .071/1.8 .134/3.4 .006/0.15 T1, T3 & ERG-2 500 5,000
F2034 16 1.50 Black .965/24.5 .708/18.0 .071/1.8 .134/3.4 .006/0.15 T1, T3 & ERG-2 500 5,000
F2035 14 2.50 Blue .591/15.0 .315/8.0 .091/2.3 .165/4.2 .006/0.15 T1, T3 & ERG-2 500 10,000
F2036 14 2.50 Blue .748/19.0 .472/12.0 .091/2.3 .165/4.2 .006/0.15 T1, T3 & ERG-2 500 5,000
F2037 14 2.50 Blue .984/25.0 .708/18.0 .091/2.3 .165/4.2 .006/0.15 T1, T3 & ERG-2 500 5,000
F2038 12 4.00 Gray .889/17.5 .394/10.0 .114/2.9 .189/4.8 .008/0.20 T3 & ERG-2 500 5,000
F2039 12 4.00 Gray .787/20.0 .472/12.0 .114/2.9 .189/4.8 .008/0.20 T3 & ERG-2 500 5,000
F2040 12 4.00 Gray 1.024/26.0 .708/18.0 .114/2.9 .189/4.8 .008/0.20 T3 & ERG-2 100 1,000
F2041 10 6.00 Yellow .787/20.0 .472/12.0 .142/3.6 .244/6.2 .008/0.20 T3 & ERG-2 100 1,000
F2042 10 6.00 Yellow .984/25.0 .708/18.0 .142/3.6 .244/6.2 .008/0.20 T3 & ERG-2 100 1,000
F2043 8 10.00 Red .827/21.0 .472/12.0 .181/4.6 .295/7.5 .008/0.20 T3 & ERG-2 100 1,000
F2044 8 10.00 Red 1.063/27.0 .708/18.0 .181/4.6 .295/7.5 .008/0.20 T3 & ERG-2 100 1,000
F2045 6 16.00 Blue .906/23.0 .472/12.0 .236/6.0 .346/8.8 .008/0.20 ERG-2 100 1,000
F2046 6 16.00 Blue 1.142/29.0 .708/18.0 .236/6.0 .346/8.8 .008/0.20 ERG-2 50 1,000
F2047 4 25.00 Yellow 1.142/29.0 .630/18.0 .295/7.5 .433/11.0 .008/0.20 ERG-2 50 500
F2048 4 25.00 Yellow 1.220/31.0 .708/18.0 .295/7.5 .433/11.0 .008/0.20 ERG-2 50 500
F2049 4 25.00 Yellow 1.378/35.0 .866/22.0 .295/7.5 .433/11.0 .008/0.20 ERG-2 50 500
F2050 2 35.00 Red 1.181/30.0 .630/16.0 .335/8.5 .492/12.5 .008/0.20 ERG-2 50 500
F2051 2 35.00 Red 1.260/32.0 .708/18.0 .335/8.5 .492/12.5 .008/0.20 ERG-2 50 500
F2052 2 35.00 Red 1.535/39.0 .984/25.0 .335/8.5 .492/12.5 .008/0.20 ERG-2 50 500
F2053 1/0 50.00 Blue 1.417/36.0 .787/20.0 .413/10.5 .591/15.0 .014/0.35 ERG-2 50 500
F2054 1/0 50.00 Blue 1.614/41.0 .984/25.0 .413/10.5 .591/15.0 .014/0.35 ERG-2 50 500
Ferrule Dimensions conform to DIN 46228. Part 4.
Insulated Ferrules
Easy to use — just strip,
slide, and crimp!
Insulated Ferrules
Ferrules are the preferred
alternative to twisting wire stands
or tinning the wire end before
terminating into a terminal block
Ferrules are thin-walled copper
tubes, which are mechanically
crimped onto the ends of
stranded wires
They are easy to use — simply
strip the wire, slide the ferrule
onto the end of the wire and crimp
Features
Ferrules ensure reliable electrical
connections when terminating
conductors in screw clamp
terminal blocks
Fraying and breaking of wire
strands is prevented and the
possibility of an unreliable
connection is minimized
Insulated ferrules prevent conductor
breakage due to bending, wire
stress, or vibration, while facilitating
wire insertions into the terminal
block clamp
How to Apply a Ferrule
Strip the insulation from the end of the wire and insert into
the insulated end of the ferrule
Using the designated crimping tool, place the metal shaft into
the tool’s appropriate slot. Compress the tool to make a
crescent-shape depression along the length of the ferrule
Insert the crimped ferrule into the terminal block
Tighten the ferrule and wire into the terminal block
Materials
High conductivity copper
Tin plating
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-22
www.tnb.com
Insulated Ferrules
Terminal Products and Tools
Terminal Products and Tools
CONDUCTOR SECTION DIMENSIONS INCHES/MM INSTALLATION BAG CASE
CAT. NO. AWG MM COLOR A B ØC ØD E TOOLING PKG. QTY. PKG. QTY.
F8000 2x 20 2x 0.50 White .591/15.0 .315/8.0 .059/1.5 .177/4.5 .010/0.25 T3 500 5,000
F8001 2x 18 2x 0.75 Gray .591/15.0 .315/8.0 .071/1.8 .201/5.1 .010/0.25 T3 500 5,000
F8002 2x 18 2x 0.75 Gray .669/17.0 .394/10.0 .071/1.8 .201/5.1 .006/0.15 T3 500 5,000
F8003 2x 17 2x 1.00 Red .591/15.0 .315/8.0 .081/2.05 .201/5.1 .006/0.15 T3 500 5,000
F8005 2x 17 2x 1.00 Red .669/17.0 .394/10.0 .081/2.05 .201/5.1 .006/0.15 T3 500 5,000
F8006 2x 16 2x 1.50 Black .630/16.0 .315/8.0 .091/2.3 .252/6.4 .006/0.15 T3 500 5,000
F8007 2x 16 2x 1.50 Black .787/20.0 .472/12.0 .091/2.3 .252/6.4 .006/0.15 T3 500 5,000
F8008 2x 14 2x 2.50 Blue .728/18.5 .394/10.0 .114/2.9 .295/7.5 .006/0.15 T3 500 5,000
F8009 2x 14 2x 2.50 Blue .846/21.5 .512/13.0 .114/2.9 .295/7.5 .006/0.15 T3 500 5,000
F8010 2x 12 2x 4.00 Gray .906/23.0 .472/12.0 .150/3.8 .339/8.6 .006/0.15 ERG-2 / 6MM DIE 100 1,000
F8011 2x 10 2x 6.00 Yellow .984/25.0 .551/14.0 .193/4.9 .378/9.6 .008/0.20 ERG-2 / 10MM DIE 100 1,000
Ferrule Dimensions conform to DIN 46228. Part 4.
CONDUCTOR SECTION DIMENSIONS INCHES/MM INSTALLATION BAG CASE
Cat. No.
STYLE AWG MM COLOR A B ØC ØD E TOOLING PKG. QTY. PKG. QTY.
F4000 OLD DIN 20 0.50 Orange .571/14.5 .315/8.0 .043/1.1 .102/2.6 .006/0.15 T1, T3 & ERG-2 500 10,000
F4001 OLD DIN 18 0.75 White .571/14.5 .315/8.0 .051/1.3 .110/2.8 .006/0.15 T1, T3 & ERG-2 500 10,000
F4002 OLD DIN 18-17 1.00 Yellow .571/14.5 .315/8.0 .059/1.5 .118/3.0 .006/0.15 T1, T3 & ERG-2 500 10,000
F4003 OLD DIN 16 1.50 Red .571/14.5 .315/8.0 .071/1.8 .134/3.4 .006/0.15 T1, T3 & ERG-2 500 10,000
F4004 26 0.14 Gray .413/10.5 .236/6.0 .031/.80 .079/2.0 .010/.25 T3, ERG2 500 10,000
F4005 26 0.14 Gray .492/12.5 .315/8.0 .031/.80 .079/2.0 .010/.25 T3, ERG2 500 10,000
F4006 24 0.25 Yellow .413/10.5 .236/6.0 .031/.80 .079/2.0 .010/.25 T3, ERG2 500 10,000
F4007 24 0.25 Yellow .492/12.5 .315/8.0 .031/.80 .079/2.0 .010/.25 T3, ERG2 500 10,000
F4008 22 0.34 Purple .413/10.5 .236/6.0 .031/.80 .079/2.0 .010/.25 T3, ERG2 500 10,000
F4009 22 0.34 Purple .492/12.5 .315/8.0 .031/.80 .079/2.0 .010/.25 T3, ERG2 500 10,000
F4020 OLD DIN 14 2.50 Blue .571/14.5 .315/8.0 .091/2.3 .165/4.2 .006/0.15 T1, T3 & ERG-2 500 10,000
F4021 FRENCH 20 0.50 White .571/14.5 .315/8.0 .043/1.1 .102/2.6 .006/0.15 T1, T3 & ERG-2 500 10,000
F4023 FRENCH 18 0.75 Lt. Blue .571/14.5 .315/8.0 .051/1.3 .110/2.8 .006/0.15 T1, T3 & ERG-2 500 10,000
F4024 FRENCH 18-17 1.00 Red .571/14.5 .315/8.0 .059/1.5 .118/3.0 .006/0.15 T1, T3 & ERG-2 500 10,000
F4027 FRENCH 16 1.50 Black .571/14.5 .315/8.0 .071/1.8 .134/3.4 .006/0.15 T1, T3 & ERG-2 500 10,000
F4028 FRENCH 14 2.50 Gray .571/14.5 .315/8.0 .091/2.3 .165/4.2 .006/0.15 T1, T3 & ERG-2 500 10,000
Ferrule Dimensions conform to DIN 46228. Part 4.
CAT. NO. DESCRIPTION STD. PKG.
T1 Sta-Kon®Crimp Tool for Wire Ferrules #20-14 AWG – Insulated Handle 1
T3 Sta-Kon®Crimp Tool for Wire Ferrules #26-10 AWG – Insulated Handle 1
ERG-2 Comfort Crimp®Sta-Kon®Crimp Tool with Shure-Stake®mechanism,
for installing wire ferrules #26-1/0 AWG. 4 interchangeable die sets 1
included. Insulated handle. Packaged in sturdy plastic carrying case.
ERG3000 Dies available.
T1
Available in a variety of colors!
Insulated Twin Ferrules
Still available and ready to work for you!
Insulated Ferrules (Old DIN and French Standards)
T3
ERG-2
The crimping tools you need!
Tooling for Sta-Kon®Insulated Ferrules
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-23
www.tnb.com
Non-Insulated Ferrules
Terminal Products and Tools
Terminal Products and Tools
CAT
.
CONDUCTOR SECTION DIMENSIONS (INCHES/MM) INSTALLATION PKG.
NO. AWG MM A C D E TOOLING QTY.
F9000 24 0.25 .196/5 .030/0.75 .067 / 1.7 .006/0.15 T1, ERG2 1,000
F9001 22 0.5 .236/6 .039/1.0 .083 / 2.1 .006/0.15 T1, T3, ERG2 1,000
F9002 22 0.5 .394/10 .039/1.0 .083 / 2.1 .006/0.15 T1, T3, ERG2 1,000
F9003 18 0.75 .236/6 .047/1.2 .091 / 2.3 .006/0.15 T1, T3, ERG2 1,000
F9004 18 0.75 .394/10 .047/1.2 .091 / 2.3 .006/0.15 T1, T3, ERG2 1,000
F9005 18 1 .236/6 .055/1.4 .098 / 2.5 .006/0.15 T1, T3, ERG2 1,000
F9006 18 1 .394/10 .055/1.4 .098 / 2.5 .006/0.15 T1, T3, ERG2 1,000
F9007 16 1.5 .276/7 .067/1.7 .110 / 2.8 .006/0.15 T1, T3, ERG2 1,000
F9008 16 1.5 .394/10 .067/1.7 .110 / 2.8 .006/0.15 T1, T3, ERG2 1,000
F9009 16 1.5 .473/12 .067/1.7 .110 / 2.8 .006/0.15 T1, T3, ERG2 1,000
F9010 16 1.5 .709/18 .067/1.7 .110 / 2.8 .006/0.15 T1, T3, ERG2 1,000
F9011 14 2.5 .276/7 .087/2.2 .139 / 3.4 .006/0.15 T1, T3, ERG2 1,000
F9012 14 2.5 .394/10 .087/2.2 .139 / 3.4 .006/0.15 T1, T3, ERG2 1,000
F9013 14 2.5 .472/12 .087/2.2 .139 / 3.4 .006/0.15 T1, T3, ERG2 1,000
F9014 14 2.5 .709/18 .087/2.2 .139 / 3.4 .006/0.15 T1, T3, ERG2 1,000
F9015 12 4 .354/9 .110/2.8 .158 / 4 .008/0.2 T3, ERG2 1,000
F9016 12 4 .472/12 .110/2.8 .158 / 4 .008/0.2 T3, ERG2 1,000
F9017 12 4 .591/15 .110/2.8 .158 / 4 .008/0.2 T3, ERG2 1,000
F9018 12 4 .709/18 .110/2.8 .158 / 4 .008/0.2 T3, ERG2 1,000
F9019 10 6 .472/12 .138/3.5 .185 / 4.7 .008/0.2 T3, ERG2 1,000
F9020 10 6 .591/15 .138/3.5 .185 / 4.7 .008/0.2 T3, ERG2 1,000
F9021 10 6 .709/18 .138/3.5 .185 / 4.7 .008/0.2 T3, ERG2 1,000
F9022 8 10 .472/12 .177/4.5 .228 / 5.8 .008/0.2 T3, ERG2 500
F9023 8 10 .591/15 .177/4.5 .228 / 5.8 .008/0.2 T3, ERG2 500
F9024 8 10 .709/18 .177/4.5 .228 / 5.8 .008/0.2 T3, ERG2 500
F9025 6 16 .472/12 .228/5.8 .295 / 7.5 .008/0.2 T3, ERG2 250
F9026 6 16 .591/15 .228/5.8 .295 / 7.5 .008/0.2 T3, ERG2 250
F9027 6 16 .709/18 .228/5.8 .295 / 7.5 .008/0.2 T3, ERG2 250
F9028 6 16 .984/25 .228/5.8 .295 / 7.5 .008/0.2 T3, ERG2 250
F9029 6 16 1.26/32 .228/5.8 .295 / 7.5 .008/0.2 T3, ERG2 250
F9030 4 25 .591/15 .287/7.3 .374 / 9.5 .010/.25 ERG2 100
F9031 4 25 .709/18 .287/7.3 .374 / 9.5 .010/.25 ERG2 100
F9032 4 25 .984/25 .287/7.3 .374 / 9.5 .010/.25 ERG2 100
F9033 4 25 1.26/32 .287/7.3 .374 / 9.5 .010/.25 ERG2 100
F9034 2 35 .709/18 .327/8.3 .433 / 11 .010/.25 ERG2 100
F9035 2 35 .984/25 .327/8.3 .433 / 11 .010/.25 ERG2 100
F9036 2 35 1.26/32 .327/8.3 .433 / 11 .010/.25 ERG2 100
F9037 Jan-00 50 .709/18 .406/10.3 .512 / 13 .012/0.3 ERG2 100
F9038 Jan-00 50 .984/25 .406/10.3 .512 / 13 .012/0.3 ERG2 100
F9039 Jan-00 50 1.18/30 .406/10.3 .512 / 13 .012/0.3 ERG2 100
A
E
DC
Ferrules for every application!
Uninsulated Ferrule Terminals
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-24
www.tnb.com
Terminal Products and Tools
Terminal Products and Tools
The heat shrinkable advantage!
A
B
WT./LBS.
PKG. WIRE MAX. BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE 1,000 A B
RAS18-6FLX 100 22-18 .170 #6 5 1.350 .25
RAS18-8FLX 100 22-18 .170 #8 5 1.350 .29
RAS18-10FLX 100 22-18 .170 #10 5 1.350 .29
RBS14-6FLX 100 16-14 .200 #6 6 1.350 .25
RBS14-8FLX 100 16-14 .200 #8 6 1.350 .29
RBS14-10FLX 100 16-14 .200 #10 6 1.350 .29
RCS10-6FLX 50 12-10 .250 #6 8 1.350 .31
RCS10-8FLX 50 12-10 .250 #8 8 1.350 .37
RCS10-10FLX 50 12-10 .250 #10 8 1.350 .37
RCS10-14FLX 50 12-10 .250 14" 8 1.350 .49
UL Listed E9809
Installing tool: WT1255
NOTE: Heat Shrinkable terminals not available on Mylar Tape.
A
M
C
B
WT./LBS.
PKG. WIRE MAX. BOLT PER DIMENSIONS
CAT. NO. QTY. RANGE INS. HOLE 1,000 A B C M
RAS18-6X 100 22-18 .170 #6 2 1.23 .25 .27 1.10
RAS18-8X 100 22-18 .170 #8 3 1.26 .31 .27 1.10
RAS18-10X 100 22-18 .170 #10 2 1.26 .31 .27 1.10
RBS14-6X 100 16-14 .200 #6 3 1.23 .25 .27 1.10
RBS14-8X 100 16-14 .200 #8 3 1.23 .25 .27 1.10
RBS14-10X 100 16-14 .200 #10 3121.26 .31 .27 1.10
RCS10-6X 50 12-10 .250 #6 3 1.34 .31 .27 1.15
RCS10-8X 50 12-10 .250 #8 5 1.34 .37 .27 1.15
RCS10-10X 50 12-10 .250 #10 5 1.34 .37 .27 1.15
RCS10-14X 50 12-10 .250 b" 6 1.34 .49 .32 1.15
UL®Listed E9809
Installing tool: WT1255
NOTE: Not available on Mylar Tape.
These ring terminals, butt splices,
and disconnects are self-insulated
with heat-shrinkable polyolefin
and internally coated sealant
Upon completed installation, a fully
sealed connection is achieved to
protect the joint against the degrading
effects of galvanic action, corrosion,
and environmental exposure
Protects joints!
Heat-Shrinkable Ring Terminals — Expanded Insulation Support
Heat-Shrinkable Locking Fork Terminals —
Expanded Insulation Support
Self-insulated with heat
shrinkable polyolefin and
internally coated sealant.
Upon completed instal-
lation, a fully sealed
connection is achieved
to protect the joint
RAS & RBS stock thickness: .03
RCS stock thickness: .04
Heat-Shrinkable Terminals, Splices, and Disconnects
Fully sealed connections!
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-25
www.tnb.com
Heat-Shrinkable Terminals, Splices, and Disconnects
Terminal Products and Tools
Terminal Products and Tools
Upon completed installation, a fully sealed connection is
achieved to protect the joint against the degrading effects
of galvanic action, corrosion, and environmental exposure
B
A
A
WT./LBS.
PKG. WIRE MAX. TAB PER
CAT. NO. QTY. RANGE INS SIZE 1,000 A
18RAS-251TX 25 22-18 .170 .250 x .032 4 1.80
14RBS-251TX 25 16-14 .200 .250 x .032 5 1.75
10RCS-251TX 25 12-10 .250 .250 x .032 6 1.80
Installing tool: WT1255
WT./LBS.
PKG. WIRE MAX. PER DIMENSIONS
CAT. NO. QTY. RANGE INS 1,000 A B
RAA217 50 22-18 .150 3 1.50 .25
2RAS18X 50 22-18 .170 3 1.50 .25
2RA18X 50 22-18 .170 3 1.50 .25
2RAA217-170 50 22-18 .170 3 150 .25
RAAS22X 500 22-18 .170 3 1.50 .25
RBB217 50 16-14 .170 3 1.50 .26
2RBS14X 50 16-14 .200 3 1.50 .26
2RB14X 50 16-14 .200 3 1.50 .26
2RBB217-200 50 16-14 .200 3 1.50 .26
RBBS22X 500 16-14 .200 3 1.50 .26
2RCS10X 25 12-10 .250 7 1.60 .31
2RC10X 25 12-10 .250 7 1.60 .31
RCC217-250 25 12-10 .250 7 1.60 .31
RCCS22X 250 12-10 .250 7 1.60 .31
RCC217 250 12-10 .210 7 1.60 .31
Installing tool: WT1255
A
These butt splices are self-insulated
with heat shrinkable polyolefin and
internally coated sealant.
Heat-Shrinkable Splices —
Butt Type — Expanded Insulation
Heat-Shrinkable — Fully Insulated
250 Disconnects — Male
Heat-Shrinkable — Fully Insulated
250 Disconnects — Female
WT./LBS.
PKG. WIRE MAX. TAB PER
CAT. NO. QTY. RANGE INS SIZE 1,000 A
RAS18-250AX 25 22-18 .170 .250 x .032 4 1.82
RBS14-250AX 25 16-14 .200 .250 x .032 5 1.77
RCS10-250AX 25 12-10 .250 .250 x .032 6 1.80
Installing tool: WT1255
The disconnects you need!
Available in the wire ranges you need!
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-26
www.tnb.com
Splice Connectors
Terminal Products and Tools
Terminal Products and Tools
MAX WT./LBS.
PKG. INS. WIRE PER DIMENSIONS
CAT. NO. QTY. DIA. RANGE 1,000 A B
2RA18 100 .115 22–18 3 1.19 .18
RAA21 1,000 .115 22–18 3 1.19 .18
2RB14 100 .148 16–14 3 1.19 .21
RBB21 1,000 .148 16–14 3 1.19 .21
2RC10 50 .210 12–10 7 1.26 .28
RCC21 500 .210 12–10 7 1.26 .28
2RD8 25 .340 8 25 1.69 .36
RDD27 200 .340 8 25 1.69 .36
2RE6 20 .420 6 35 1.85 .45
REE28 200 .420 6 35 1.85 .45
2RF4 15 .510 4 40 1.85 .52
UL Listed E9809
Installing tools: ERG-2001, ERG-2003, WT145C, WT112M, TBM6/TBM6S (D-F)
NOTE: Not available on Mylar Tape.
WT./LBS.
PKG. WIRE PER DIMENSIONS
CAT. NO. QTY. RANGE 1,000 A B
2RZZ 50 26–22 2 1.22 .15
2RAA 50 22–18 6 1.52 .25
RAA23 500 22–18 6 1.52 .25
2RBB 50 16–14 6 1.52 .28
RBB23 500 16–14 6 1.52 .28
2RCC 25 12–10 8 1.53 .35
RCC23 250 12–10 8 1.53 .35
Not UL®Listed
Installing Tools: WT145C, ERG-2001, ERG-2003 (For RAA, RBB, RCC Only), WT1452 (RZZ)
B
A
Butt Type Splices
B
A
Wires are butted together and crimped at each end of the splice
Available either non-insulated or insulated with nylon or PVC
Nylon insulated splices meet or exceed the requirements
of MIL-T-7928
Color-coded according to wire size
WT./LBS.
PKG. WIRE MAX. PER DIMENSIONS
CAT. NO. QTY. RANGE INS 1,000 A B
2RA18X 100 22–18 .170 3 1.13 .25
RAA217-170 1,000 22–18 .170 3 1.13 .25
RAA217 1,000 22–18 .155 3 1.13 .23
2RB14X 100 16–14 .200 3 1.13 .26
RBB217-200 1,000 16–14 .200 3 1.13 .26
RBB217 1,000 16–14 3 1.13 .23
2RC10X 50 12–10 .210 7 1.31 .31
RCC217-250 500 12–10 .250 7 1.31 .31
RCC217 1,000 12–10 .210 7 1.31 .29
UL Listed E9809
Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003
Bulk Nos.: RAA22X– RBB22X – RCC22X
B
A
A, B, and C bulk numbers can be put on Mylar Tape for reel-fed
applications (i.e., 12050 tool and application dies).
Please put the suffix “M” for Mylar Tape RA2573M.
(Bulk number 1,000 and 500 packages.)
Select the wire range and quantity needed!
UL Listed E9809!
Engineered for aircraft systems!
Meets or exceeds MIL-T-7928 requirements!
Nylon Insulated Splices —
Aircraft Systems Splices
WT./LBS.
PKG. WIRE PER DIMENSIONS
CAT. NO. QTY. RANGE 1,000 A B
2A-18 100 22–18 212.62 .12
AA2 1,000 22–18 212.62 .12
2B-14 100 16–14 212.62 .16
BB2 1,000 16–14 212.62 .16
2C-10 50 12–10 7 .72 .22
CC2 500 12–10 7 .72 .22
2D-8 25 9–8–7 18 1.03 .28
DD102 200 9–8–7 18 1.03 .28
2E-6 20 6–5 25 1.12 .37
EE2 200 6–5 25 1.12 .37
2F-4 15 4–3 30 1.25 .44
FF2 200 4–3 30 1.25 .44
2G21 5 2–1 40 1.72 .55
GG2 25 2–1 40 1.72 .55
Installing tools: A, B, C: WT111M, WT110M, WT2000, ERG-2002, WT112M
Installing tools: D, E, F, G: WT115A, TBM6/TBM6S
Nylon Insulated Splices —
Butt Type — Insulation Support
Vinyl Insulated Splices —
Butt Type — Expanded Insulation
Non-Insulated Splices — Butt Type
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-27
www.tnb.com
Splice Connectors
Terminal Products and Tools
Terminal Products and Tools
B
A
Wires are laid side by side in the
connector, and the connection is
made in one crimp
Offer advantages in simplicity
of installation and small size
One crimp completes the splice
WT./LBS. MAX.
PKG. WIRE PER DIMENSIONS INS.
CAT. NO. QTY. RANGE 1,000 A DIA.
RAAT21 1,000 22–18 3 1.22 .115
RBBT21 1,000 16–14 3 1.22 .148
RCCT21 1,000 12–10 7 1.22 .210
Installing tool: WT-145C
Tefzel®is a registered trademark of DuPont.
Sta-Kon®Parallel Splices
Provide excellent reliability, long-term performance, and a UL listed
connection at a low installed cost
Resistant to corrosion and preserve the electrical integrity of the wires
in single or multiple strands
Feature an intelligent constructable part number for quick identification
of the wire range and pack quantity
Offers solutions for hundreds of
OEM, utility, and communications
applications!
WIRE CIR MIL LENGTH O.D. I.D. PACK UPC
CAT. NO. SIZE RANGE (A) (B) (C) QTY. NUMBER
A18-PS-M 22–16 AWG 509–3,260 0.314 0.129 0.086 1,000 78621093625
B14-PS-M 16–14 AWG 2,050–5,180 0.315 0.155 0.113 1,000 78621093626
C10-PS-D 12–10 AWG 5,180–13,100 0.380 0.220 0.170 500 78621093627
D8-PS-D 8 AWG 13,100–20,800 0.375 0.260 0.180 500 78621089076
E6-PS-D 6 AWG 20,800–33,100 0.500 0.365 0.266 500 78621089080
F4-PS-W 4 AWG 33,100–52,600 0.531 0.410 0.302 250 78621089082
G2-PS-W 2 AWG 52,600–83,700 0.640 0.521 0.396 250 78621089084
H1/0-PS-C 1/0 AWG 83,700–119,500 0.750 0.571 0.446 100 78621089086
J2/0-PS-C 2/0 AWG 119,500–150,500 0.750 0.632 0.507 100 78621089078
K3/0-PS-L 3/0 AWG 150,500–190,000 0.750 0.701 0.564 50 78621089777
L4/0-PS-L 4/0 AWG 190,000–231,100 0.770 0.766 0.629 50 78621089092
M250-PS-Q 250 MCM 231,100–300,000 1.063 0.926 0.749 25 78621089094
N300-PS-X 300 MCM 300,000–380,000 1.125 1.100 0.882 10 78621089096
P400-PS-X 400 MCM 380,000–478,000 1.250 1.200 0.956 10 78621089098
R500-PS-V 500 MCM 478,000–600,000 1.438 1.330 1.060 5 78621089100
The total combined cross sectional area of all wires must be within the CMA range.
Easy to install! Color coded according to wire size!
Wire Size Tools
22–10 AWG ERG2002, WT111M, WT112M, WT2000
16–6 AWG ERG2005
8–2 AWG WT115A, TBM8-750M1, TBM8-750BSCR
1/0 AWG–500 MCM TBM8-750M1, TBM8-750BSCR
WT./LBS.
PKG. WIRE PER DIMENSIONS
CAT. NO. QTY. RANGE 1,000 A B
2A20 100 22–20 2 .84 .20
RAA24 1,000 22–20 2 .84 .20
2B-16 100 18–16 2 .84 .23
RBB25 1,000 18–16 2 .84 .23
2C-12 50 14–12 4 .90 .28
RCC26 500 14–12 4 .90 .28
UL®Listed E9809
Installing tools: WT2000, WT112M
Nylon Insulated Splices —
Overlap Type (Parallel)
Tefzel®Insulated Butt Splice
A
B
C
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
Material — Tin-plated Copper
Range — 22AWG to 500 MCM
Listing — UL, CSA Listed
. . . . Specifications . . . .
C-28
www.tnb.com
Disconnects
Terminal Products and Tools
Terminal Products and Tools
RA18-250F
Nylon self-insulated
Installing tools: WT145C, WT2000, ERG-2001,
ERG-2003, WT112M
Supplied in a variety of styles to meet virtually
all quick-disconnect requirements
Female disconnect terminals and matching
male tabs accommodate a range of 22–10
AWG, and are available in non-insulated,
partially insulated, and fully insulated styles,
in both nylon and vinyl
Available in various tab widths including .250",
.187", and .110", and a combination size
Unique construction of the female disconnect
offers long-term dependability
Brazed seam serrated barrel provides
maximum tensile strength
Most standard bulk catalog numbers can be put on Mylar
Tape for reel-fed applications (i.e., 12050 tool and application
dies). See pages C??- C?? for description of tooling.
Please add the suffix “M” for Mylar Tape (i.e., RA2573-M).
Quick, reliable method of connection to terminal blocks and boards without the use of tools!
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
250 Series — Female
Disconnects
CAT. PKG. WIRE MAX. TAB WT./LBS. DIMENSIONS
NO. QTY. RANGE INS. SIZE PER 1,000 A B
RA18-250F 100 22–18 .136 .250 x .032 4 .91 .29
RA250 1,000 22–18 .136 .250 x .032 4 .91 .29
RB14-250F 100 16–14 .162 .250 x .032 4 .91 .29
RB250 1,000 16–14 .162 .250 x .032 4 .91 .29
RC10-250F 50 12–10 .215 .250 x .032 4 1.04 .29
RC250 500 12–10 .215 .250 x .032 4 1.04 .29
18RA-250F 100 22–18 .150 .250 x .032 3 .96 .29
RA257 1,000 22–18 .150 .250 x .032 3 .96 .29
RA257-170 1,000 22–18 .170 .250 x .032 .96 .29
14RB-250F 100 16–14 .170 .250 x .032 3 .96 .29
RB257 1,000 16–14 .170 .250 x .032 3 .96 .29
RB257-200 1,000 16–14 .200 .250 x .032 .96 .29
10RC-250F 50 12–10 .250 .250 x .032 4 1.03 .29
RC257 500 12–10 .250 .250 x .032 4 1.03 .29
18RA-2577 100 22–18 .165 .250 x .032 3 1.01 .38
RA2573 1,000 22–18 .165 .250 x .032 3 1.01 .38
14RB-2577 100 16–14 .185 .250 x .032 4 1.01 .38
RB2573 1,000 16–14 .185 .250 x .032 4 1.01 .38
10RC-2577 50 12–10 .225 .250 x .032 5 1.04 .38
RC2573 500 12–10 .225 .250 x .032 5 1.04 .38
RAS18-250AX 50 22–18 .170 .250 x .032 4 1.83
RBS14-250AX 50 16–14 .200 .250 x .032 5 1.78
RCS10-250AX 25 12–10 .250 .250 x .032 6 1.80
RA18-250A 50 22–18 .170 .250 x .032 4 .80 .71
RA2577F 500 22–18 .170 .250 x .032 4 .80 .71
RB14-250A 50 16–14 .190 .250 x .032 5 .80 .72
RB2577F 500 16–14 .190 .250 x .032 5 .80 .72
RC10-250A 50 12–10 .245 .250 x .032 6 .80 .88
RC2577F 500 12–10 .245 .250 x .032 6 .80 .88
A18-250 100 22–18 .250 x .032 3 .73 .31
A250 1,000 22–18 .250 x .032 3 .73 .31
B14-250 100 16–14 .250 x .032 3 .73 .31
B250 1,000 16–14 .250 x .032 3 .73 .31
C10-250F 50 12–10 .250 x .032 4 .73 .31
C250 500 12–10 .250 x .032 4 .73 .31
B14-250F 100 16–14 .250 x .032 5 .87 .31
B250G 1,000 16–14 .250 x .032 5 .87 .31
A18-250A 50 22–18 .250 x .032 3 .58 .61
A252G 500 22–18 .250 x .032 3 .58 .61
B14-250A 50 16–14 .250 x .032 3 .58 .62
B252G 500 16–14 .250 x .032 3 .58 .62
C10-250A 50 12–10 .250 x .032 4 .64 .63
C252G 500 12–10 .250 x .032 4 .64 .63
Material: brass Finish: tin plated
UL®Listed E66716
B
A
A
B
1
18RA-250F
Vinyl self-insulated
Installing tools: WT145C, WT2000, ERG-2001,
ERG-2003, WT112M
18RA-2577
Nylon fully insulated
Installing tools: WT145C, WT2000, ERG-2001,
ERG-2003, WT112M
RAS18-250AX
Heat-shrinkable fully insulated disconnects
Installing tool: WT1255
A18-250
Non-insulated
Installing tools: WT111M, WT1110M, WT2000,
ERG-2002, WT112M
B14-250F
Non-insulated/insulation grip
Installing tool: WT110M
RA18-250A
Nylon open top insulated 90° flag
Installing tools: WT145C, WT2000, ERG-2001,
ERG-2003, WT112M
A18-250A
Non-insulated 90° flag
Installing tools: WT110M, WT111M, WT2000,
ERG-2002, WT112M
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
C-29
www.tnb.com
Disconnects
Terminal Products and Tools
Terminal Products and Tools
B
C
30
O
A
Designed for stacking applications!
Quick, reliable method of connection to terminal
blocks and boards without the use of tools
Supplied in a variety of styles to meet virtually
all quick-disconnect requirements
Female disconnect terminals and matching
male tabs accommodate a range of 22–10
AWG, and are available in non-insulated,
partially insulated, and fully insulated styles,
in both nylon and vinyl
Available in various tab widths including .250",
.187", and .110", and a combination size
Unique construction of the female disconnect
offers long-term dependability
Most standard bulk catalog numbers can be put on
Mylar Tape for reel-fed applications (i.e., 12050 tool
and application dies). See pages C??- C?? for
description of tooling.
Please add the suffix “M” for Mylar Tape (i.e., RA2573-M).
Connect without tools!
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
250 Series — Piggy Back Disconnects — Nylon Insulated
187 Series — Female
Disconnects
B
A
A
B
RAD18-183
Nylon self-insulated
Installing tools: WT145C, WT2000, ERG-2001,
ERG-2003, WT112M
1
18RAD-183
Vinyl self-insulated
Installing tools: WT145C, WT2000, ERG-2001,
ERG-2003, WT112M
18RAD-18377
Nylon fully insulated
Installing tools: WT145C, WT2000, ERG-2001,
ERG-2003, WT112M
AD18-183
Non-insulated
Installing tools: WT111M, ERG-2002, WT2000,
WT112M
RAD18-187A
Nylon fully insulated 90° flag
Installing tools: WT1145C, WT2000, ERG-2001,
ERG-2003, WT112M
2
3
4
5
CAT. PKG. TAB WIRE MAX. DIMENSIONS
NO. QTY. SIZE RANGE INS. DIA. A B
RAD18-183 100 .187 x .032 22–18 .136 .83 .23
RAD1833 1,000 .187 x .032 22–18 .136 .83 .23
RAD18-182 100 .187 x .020 22–18 .136 .83 .23
RAD1823 1,000 .187 x .020 22–18 .136 .83 .23
RBD14-183 100 .187 x .032 16–14 .163 .83 .23
RBD1833 1,000 .187 x .032 16–14 .163 .83 .23
RBD14-182 100 .187 x .020 16–14 .163 .83 .23
RBD1823 1,000 .187 x .020 16–14 .163 .83 .23
18RAD-183 100 .187 x .032 22–18 .150 .85 .23
RAD1837 1,000 .187 x .032 22–18 .150 .85 .23
18RAD-182 100 .187 x .020 22–18 .150 .85 .23
RAD1827 1,000 .187 x .020 22–18 .150 .85 .23
14RBD-183 100 .187 x .032 16–14 .170 .85 .23
RBD1837 1,000 .187 x .032 16–14 .170 .85 .23
14RBD-182 100 .187 x .020 16–14 .170 .85 .23
RBD1827 1,000 .187 x .020 16–14 .170 .85 .23
18RAD-18377 100 .187 x .032 22–18 .150 .89 .30
RAD18377 1,000 .187 x .032 22–18 .150 .89 .30
18RAD-18277 100 .187 x .020 22–18 .150 .89 .30
RAD18277 1,000 .187 x .020 22–18 .150 .89 .30
14RBD-18377 100 .187 x .032 16–14 .170 .89 .30
RBD18377 1,000 .187 x .032 16–14 .170 .89 .30
14RBD-18277 100 .187 x .020 16–14 .170 .89 .30
RBD18277 1,000 .187 x .020 16–14 .170 .89 .30
AD18-183 100 .187 x .032 22–18 .64 .23
AD183 1,000 .187 x .032 22–18 .64 .23
AD18-182 100 .187 x .020 22–18 .64 .23
AD182 1,000 .187 x .020 22–18 .64 .23
BD14-183 100 .187 x .032 16–14 .64 .23
BD183 1,000 .187 x .032 16–14 .64 .23
BD14-182 100 .187 x .020 16–14 .64 .23
RAD18-187A 50 .187 x .032 22–18 .150 .74 .59
RAD1877F 500 .187 x .032 22–18 .150 .74 .59
RAD18-188A 50 .187 x .020 22–18 .150 .74 .59
RAD1887F 500 .187 x .020 22–18 .150 .74 .59
RBD14-187A 50 .187 x .032 16–14 .170 .74 .61
RBD1877F 500 .187 x .032 16–14 .170 .74 .61
RBD14-188A 50 .187 x .020 16–14 .170 .74 .61
RBD1887F 500 .187 x .020 16–14 .170 .74 .61
Material: brass Finish: tin plated U.L. Listed E66716
1
2
3
4
5
CAT. PKG. WIRE MAX. TAB WT./LBS. DIMENSIONS
NO. QTY. RANGE INS. SIZE PER 1,000 A B C
RA18-250FP 100 22–18 .136 .250 x .032 3 .87 .30 .43
RA250P 1,000 22–18 .136 .250 x .032 3 .87 .30 .43
RB14-250FP 100 16–14 .163 .250 x .032 3 .87 .30 .43
RB250P 1,000 16–14 .163 .250 x .032 3 .87 .30 .43
For stacking applications. Installing Tool: WT112M
C-30
www.tnb.com
Disconnects
Terminal Products and Tools
Terminal Products and Tools
A
B
Most standard bulk catalog numbers can be put on Mylar
Tape for reel-fed applications (i.e., 12050 tool and applica-
tion dies).
Please add the suffix “M” for Mylar Tape (i.e., RA2573-M).
A
B
B
A
A
B
Select the tabs you need!
Insulated coupler requires no tool!
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
18RA-250T
Vinyl self-insulated
Installing tools: WT145C, WT2000, ERG-2001,
ERG-2003, WT112M
250 Series — Male Tabs
187 Series — Male Tabs
250 Series —
Adapters and Coupler
1
18RA-251T
Nylon fully insulated
Installing tools: WT145C, WT2000, ERG-2001,
ERG-2003, WT112M
18RAS-251TX
Heat-shrinkable nylon fully insulated
Installing tool: WT1255
A18-250T
Non-insulated/insulated grip
Installing tool: WT110M
18RAD-187
Vinyl insulated
Installing tools: WT145C, WT2000, ERG-2001,
ERG-2003, WT112M
F250TA
Non-insulated
18-251T
Non-insulated
Installing tools: WT110M, WT111M, WT2000,
WT112M, ERG-2002, WT112M
RB14-250
Insulated coupler
No tool required
Male
2
3
4
5
6
7
8
CAT. PKG. WIRE MAX. TAB WT./LBS. DIMENSIONS
NO. QTY. RANGE INS. SIZE PER 1,000 A B
18RA-250T 100 22–18 .150 .250 x .032 3 .95
RA2517 1,000 22–18 .150 .250 x .032 3 .95
14RB-250T 100 16–14 .170 .250 x .032 3 .95
RB2517 1,000 16–14 .170 .250 x .032 3 .95
10RC-250T 50 12–10 .250 .250 x .032 4 1.08
RC2517 500 12–10 .250 .250 x .032 4 1.08
18RA-251T 50 22–18 .150 .250 x .032 5 1.13 .45
RA25177 500 22–18 .150 .250 x .032 5 1.13 .45
14RB-251T 50 16–14 .170 .250 x .032 5 1.13 .45
RB25177 500 16–14 .170 .250 x .032 5 1.13 .45
10RC-251T 25 12–10 .210 .250 x .032 5 1.17 .45
RC25177 500 12–10 .210 .250 x .032 5 1.17 .45
18RAS-251TX 50 22–18 .170 .250 x .032 4 1.80
14RBS-251TX 100 16–14 .200 .250 x .032 5 1.75
10RCS-251TX 100 12–10 .250 .250 x .032 6 1.80
A18-250T 100 22–18 .250 x .032 3 .87
B14-250T 100 20-14 .250 x .032 3 .87
A18-251T 100 22–18 .250 x .032 2 .68
A251 1,000 22–18 .250 x .032 2 .68
B14-251T 100 16–14 .250 x .032 2 .68
B251 1,000 16–14 .250 x .032 2 .68
C10-251T 50 12–10 .250 x .032 2 .68
Material: brass Finish: tin plated
CAT. PKG. TAB WT./LBS. DIMENSIONS
NO. QTY. SIZE PER 1,000 A B
F250TA 50 .250 x .032 3 .82 .56
FTA250 500 .250 x .032 3 .82 .56
RB14-250 50 .250 x .032 7 2.35 .51
RBB250 500 .250 x .032 7 2.35 .51
† Not UL Listed
Cat. No. F250TA — Material: brass Finish: tin plated
Cat. No. RB14-250 — Material: brass Finish: none Insulation: vinyl
CAT. PKG. TAB WIRE MAX WT./LBS. DIA.
NO. QTY. SIZE RANGE INS. PER 1,000 A
18RAD-187 100 .187 x .032 22–18 .150 4 .87
18RAD-188 100 .187 x .020 22–18 .150 4 .87
14RBD-187 100 .187 x .032 16–14 .170 4 .87
14RBD-188 100 .187 x .020 16–14 .170 4 .87
UL®Listed E66716 Material: brass Finish: tin plated
1
2
3
4
5
6
7
8
C-31
www.tnb.com
Disconnects
Terminal Products and Tools
Terminal Products and Tools
Most standard bulk catalog numbers can be put on
Mylar Tape for reel-fed applications (i.e., 12050
tool and application dies). See pages C??- C??.
Please put the suffix “M” for Mylar Tape RA2573M.
(Bulk number 1,000 and 500 packages.)
A
B
A
A
Nylon Insulated and Non-insulated
Picture shows wristlock assembled as 2 pieces.
Parts are sold by the piece not assemblies.
Convenient 20-count packaging!
Choose from nylon-insulated or non-insulated!
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
Available in variety of wire ranges!
RA18-111F
Nylon-insulated
Installing tool: WT465
110 Series — Disconnects*
Sta-Kon®
Mini-Pack
Terminals
Wristlock Disconnects
9
A18-111F
Non-insulated
Installing tools: WT111M, WT2000, WT112M
RA18D
Nylon-insulated wire barrels
Installing tool: WT2000 (Not UL)
B14-D
Non-insulated/insulation grip
Installing tool: WT110M (Not UL)
10
11
12
CAT. PKG. TAB WIRE MAX WT./LBS. DIMENSIONS
NO. QTY. SIZE RANGE INS. PER 1,000 A B
RA18-110F 100 .110 x .032 22–18 .110 4 .75 .15
RA10 1,000 .110 x .032 22–18 .110 4 .75 .15
RA18-111F 100 .110 x .020 22–18 .110 4 .75 .15
RA11 1,000 .110 x .020 22–18 .110 4 .75 .15
RB14-110F 100 .110 x .032 16–14 .135 4 .75 .15
RB10 1,000 .110 x .032 16–14 .135 4 .75 .15
RB14-111F 100 .110 x .020 16–14 .135 4 .75 .15
RB11 1,000 .110 x .020 16–14 .135 4 .75 .15
A18-110F 100 .110 x .032 22–18 3 .59 .15
A10 1,000 .110 x .032 22–18 3 .59 .15
A18-111F 100 .110 x .020 22–18 3 .59 .15
A11 1,000 .110 x .020 22–18 3 .59 .15
B14-110F 100 .110 x .032 16–14 3 .59 .15
B10 1,000 .110 x .032 16–14 3 .59 .15
B14-111F 100 .110 x .020 16–14 3 .59 .15
B11 1,000 .110 x .020 16–14 3 .59 .15
*Not UL Listed or CSA approved.
Material: brass Finish: tin plated
CAT. PKG. WIRE MAX. WT./LBS. DIMENSIONS
NO. QTY. RANGE INS. PER 1,000 A A1
RA18D 50 22–18 .136 4 .99 1.70
RA23 500 22–18 .136 4 .99 1.70
RB14D 50 16–14 .162 4 .99 1.70
RB23 500 16–14 .162 4 .99 1.70
B14-D 50 16–14 .187 4 .97 1.66
B23 500 16–14 .187 4 .97 1.66
† Not UL Listed NOTE: Not available on Mylar Tape.
10
11
12
9
RA Series requires a 12061 Die.RB Series requires a 12062 Die.
CAT.
UNIT STD. WIRE BOLT
NO.
QTY. PACK. RANGE HOLE
18RA-6FCP 20 100 22–18 #6
18RA-8CP 20 100 22–18 #8
18RA-10CP 20 100 22–18 #10
14RB-6CP 20 100 16–14 #6
14RB-8CP 20 100 16–14 #8
14RB-10CP 20 100 16–14 #10
10RC-10CP 20 100 12–10 #10
10RC-14CP 20 100 12–10 1⁄4
18RA-8FCP 20 100 22–18 #8
18RA-10FCP 20 100 22–18 #10
14RB-6FCP 20 100 16–14 #6
14RB-8FCP 20 100 16–14 #8
14RB-10FCP 20 100 16–14 #10
10RC-8FCP 20 100 12–10 #8
10RC-10FCP 20 100 12–10 10
2RA18XCP 20 100 22–18
2RB14XCP 20 100 16–14
2RC10XCP 20 100 12–10
18RA-250FCP 20 100 22–18
14RB-250FCP 20 100 16–14
10RC-250FCP 20 100 12–10
UL Listed E9809
Wire ranges
from 22 AWG
to 10 AWG
Vinyl insulated ring
and forked-tongued
terminals, female
disconnects, butt-
type splice
connectors
NOTE: “CP” designates mini-pack quantities. Refer to other
catalog pages for description and dimensional information.
C-32
www.tnb.com
Wire Joints — Nylon Insulated
Terminal Products and Tools
Terminal Products and Tools
PKG. WIRE RANGE DIMENSIONS WT./LBS.
CAT. NO. QTY. MIN. MAX. A B PER 1,000
RB44 100 2#18 2#16 .31 .78 2
RB4 1,000 2#18 2#16 .31 2 2
RC55 50 4#18 2#12 .43 .95 3
RC6 500 4#18 2#12 .43 3 3
RP12 100 3#14 4#12 .53 1.00 3
RP7 1,000 3#14 4#12 .53 1.00 3
PT66M 100 2#18 3#12 combination 4
PT6M 100 Insulator only .50 .93 2
PT60M 100 2#14 3#12 Connector only .31 .37 2
PT70 200 2#14 3#12 .29 .34 2
PT70M 200 3#18 4#12 .31 .37 2
PT80 50 2#16 4#10 .35 .62 6
UL®Listed E9809
Items on this page sold in multiples of unit packages only.
Twist wires, insert through
serrated barrel of wire joint.
(PT60M, PT70, PT70M, PT80).
Crimp and trim off excess wire
with WT161M hand tool.
Screw PT6 insulator firmly onto
PT160M barrel.
B
A
B
A
T&B
B
A
T&B
B
A
Available in one-piece nylon, self-insulated
and non-insulated, and a two-piece nylon insulator.
Crimp-On Wire Joints — Tool Applied
Installation Procedure for “PT” Connectors
1
2
3
1
2
3
1 2 3
One Piece
Nylon self-insulated
Installing tools: WT2000, WT2130A (RC & RP)
Two Piece
Nylon insulator
Installing tool: WT161M
One Piece
Non-insulated
Installing tool: WT161M
ALLOWABLE WIRE COMBINATIONS
CAT. NO. #22 #20 #18 #16 #14 #12 #10
2–3
1–2 2
3
3
31
RB4/RB44 23
1–2 2
21
31
12
21
12
ALLOWABLE WIRE COMBINATIONS
CAT. NO. #22 #20 #18 #16 #14 #12 #10
1–4 1
1–3 1
1–2 1
2
3–5 1
2–4 1
RC6/RC55 3
1–4 2
1–3 2
1–3 3
13
2
5
4–6
ALLOWABLE WIRE COMBINATIONS
CAT. NO. #22 #20 #18 #16 #14 #12 #10
2
11
11
2–4
2–4 1
RP7/RP12 1–3 2
13
3–6
1 2–3
2 1–2
31
2
41
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-33
www.tnb.com
Installing Kits & Application Tools
Terminal Products and Tools
Terminal Products and Tools
ORG-2
Heavy-duty steel drawer! Perfect for
residential or
light commercial
installations!
STD. PKG. UPC
CAT. NO. DESCRIPTION QTY. NUMBER
STA-ORG Sta-Kon®Sta-OrgTerminal 1 78621093652
and Splice Organizer Kit
Ideal for contractors, OEMs, or any
other user of terminals and splices
Slips in a tool box or sits on your
bench — only 6.6"L x 3" dia.
Benchmountable (hardware
included)
Lightweight, durable,
nylon construction!
Interchangeable cassettes enable
the user to strip a wide range of
insulations without having to
change tools
Tool automatically strips wire
to preset length
Integral wire
cutter lets user
cut and strip with
the same tool!
CAT NO. DESCRIPTION WEIGHT EACH
ERG1-WS Ergonomic Wire Stripping Tool .3 lbs.
SBC-1 Replacement Straight Blade Cassette .03 lbs.
VBC-1 Replacement “V” Blade Cassette .03 lbs.
ERG1-WS Wire Stripping/Cutting Tool is shipped with one Straight Blade Cassette. “V” Blade
Cassettes sold separately. Tool and Replacement Blades are shipped in packaging suitable
for merchandising display.
“V” Blade Cassette
SWS01/DWS02 Wire
Stripping/Cutting Tools
CAT NO. DESCRIPTION
SWS01 Single-Side Stripper
DWS02 Double-Side Stripper
SWS01
DWS02
Wiring Organizer
Does not include
Thomas & Betts
products
STD.
CAT. NO. DESCRIPTION PKG. WT.
ORG2 Heavy-Duty Steel Drawer with (17) compartments 1 4 lbs.
to hold Sta-Kon®terminals, Color-Keyed®lugs,
Ty-Rap®cable ties, and other small parts
Sta-Kit
Assortment of
popular Sta-Kon®
vinyl terminals
Kit includes
a WT112M
crimping tool
All splices,
terminals, and
disconnects are
vinyl insulated
Single operation to cut
and strip at the same time!
Automatic adjustment to the
diameter of the wire, with neither
setting nor selection
Sharply cuts and strips insulator
without damaging the conductors
DWS02 is a double-side stripper
Sta-Kon®ERG1-WS Wire
Stripping/Cutting Tool
Sta-OrgTerminal and
Splice Organizer Kit
STD.
CAT. NO. DESCRIPTION PKG. WT.
STAKIT (100) 2RA18X butt splices for 22–18 AWG, 1 1lb.
(100) 2RB14X butt splices for 18–14 AWG,
(50) 2RC10X butt splices for 12–10 AWG,
(50) 10RC-10 ring terminals for 12–10 AWG,
(50) 10RC-10FL locking fork terminals for 12–10 AWG,
(50) 10RC-250F disconnects for 12–10 AWG,
(100) 14RB-10 ring terminals for 18–14 AWG,
(100) 14RB-8FL locking fork terminals for 18–14 AWG,
(100) 14RB-250F disconnects for 18–14 AWG,
(100) 18RA-8F Fork Terminals for 22–18 AWG,
(100) 18RA-6FL locking fork terminals for 22–18 AWG,
(100) 18RA-250F disconnects for 22–18 AWG
(1) WM-0-9 wire marker book
(1) WT112M crimping tool and 100 TY525M
Ty-Rap®cable ties (approx. length 712")
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-34
www.tnb.com
Application Tools
Used for installation of various Sta-Kon® terminal series.
Terminal Products and Tools
CRIMPING NEST FOR
INSULATED STA-KONS®
1 1/4"
WIRE CUTTER
2- 15/16"
THOMAS & BETTS
FOR A, B & C
STA-KON TERMINALS
WT 112M
STA-KON® LUG
A 22 TO 18
B 18 TO 14
C 12 TO 10
WT 111M
1/4"
9 19/32" 2 15/16"
PLASTISOL
HANDLES
CUTTERS
INSTALLS “A” & “B” STA-KON® TERMINALS
GAUGING .027-.053
INSTALLS “C” STA-KON TERMINALS
GAUGING 072- 098
Crimping Nest for insulated
Sta-Kon®
Crimping Nest for non-insulated
Sta-Kon®
Wire Cutter
STD. WT.
CAT. NO. DESCRIPTION PKG. EACH
WT110M A, B, C non-insulated terminal and splices and A, B 1 1
non-insulated terminals with insulation grip 1 1
WT111M A, B, C, PT non-insulated terminal and splices
WT112M RA, RB, A, B, C, non-insulated and RC insulated nylon 1 1
and vinyl terminal and splices
STD. WT.
CAT. NO. DESCRIPTION PKG. EACH
WT161M A, B, C, PT non-insulated terminal and splices 1 1
WT2000 A, B, C: AB, PT, RA, RB, RC insulated and non-insulated 1 ????
terminal and splices
INSTALLS "C" STA-KON
® TERMINALS-GAUGING .075-.095
INSTALLS "A & B" STA-KON
® TERMINALS-GAUGING .030-.050
CLOSING INSULATION GRIP ON STA-KON
® "B" SIZE TERMINALS
SCO C S
NOTE: ONLY THIS HANDLE
PAINTED GREEN
M22520/24-01
A B
C
STA-KON
® LUG
A 22 TO 18
B 18 TO 14
C 12 TO 10
9-19/32"
Plastisol handle grips
Colors: Black & Orange
Black plastisol handle grip
Orange plastisol handle grip
21516"
114"
WT110M
WT112M
Available in a variety of styles —
some with wire cutters and strippers
#22–10 AWG wire range
Plier Type Tools
PLIE
WIRE CUTTER
STA-KON®
INSTALLING NEST
.070
.080
HION GRIP HANDLE
WIRE CUTTER
HANDLE RETURN
SPRINGS
WIRE STRIPPER
LATCH
HANDLE GRIPS
CRIMP INDICATOR GAUGE
CRIMPING NEST FOR INSULATED
CGSOOS
2-3/16"
22-10
22-10 INSUL
NON
INSUL
4-40
8-32
10-32
10-24
6-32
ABC
STR SOL
22-20
18
16
14
12
10
18
16
14
12
10
8
Cushion Grip Handle
Insulation Crusher
.070
.080
Wire Cutter Installing Nest
Wire Cutter
Handle Return
Spring
Wire Stripper
Latch
Cutters
Crimp Indicator Gauge
Terminal Products and Tools
Installs “A & “B” Sta-Kon®Terminals — Gauging .027–.053
Installs “C” Sta-Kon®Terminals — Gauging .072–.098
Wire Cutter
Plastisol handle grips
Colors: Black & Orange
Plastisol handle grips
Colors: Black & Orange
215
16"9 19
32"
919
32"
114"
Crimping Nest for insulated
Crimping Nest for non-insulated
2316"
Plastisol handle grips
Color: Black & Orange
WT161M
WT2000
Installs “C” Sta-Kon®Terminals — Gauging .075–.095
Installs “A & “B” Sta-Kon®Terminals — Gauging .030–.050
Closing Insulation Grip on Sta-Kon®“B” Size Terminals and Disconnect Tips
Closing Insulation Grip on Sta-Kon®“A Size Terminals and Disconnect Tips
WT111M
Plier Grip
WT110M
Installs “C” Sta-Kon®
terminals — gauging
.075–.095
Installs “A & “B”
Sta-Kon®terminals — gauging .030–.050
Closing Insulation Grip on Sta-Kon®“B” size terminals and disconnect tips
Closing Insulation Grip on Sta-Kon®“A size terminals and disconnect tips
WT111M
Cutters
Installs “A & “B”
Sta-Kon®terminals —
gauging .027–.053.
Installs “C” Sta-Kon®terminals-gauging .072–.098
WT112M
Installs insulated
and non-insulated
Sta-Kon®terminals,
splices, disconnects,
and wire joints 22–10 AWG
WT161M
Installs “A,” “B, and “C” size (#18–#10 wire) Sta-Kon®
terminals, splices, and
wire joints
(PT-60M and PT-70)
WT2000
Wire cutter — No. 10 AWG and smaller, solid or stranded wire
Crimping nests — insulated and non-insulated Sta-Kon®terminals, splices,
and wire joints on No. 22 to No. 10 AWG, solid or stranded wire
Cutters — chasing
feature for screws,
sizes 4–40, 6–32,
8–32, 10–24, 10–32
Wire stripper — removes
most types of insulation from No. 22–10
AWG stranded wire and No. 18–8 AWG solid wire
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-35
www.tnb.com
Application Tools
Terminal Products and Tools
Terminal Products and Tools
Concerned about safety? Down time? Health care costs?
The Thomas & Betts ergonomically-designed Comfort Crimp®tool helps
reduce the risk of carpal tunnel syndrome, the cause of almost one out of
every two industrial injuries.
This tool’s unique design delivers the same reliable crimp with up to 60%
less handle force than other terminal hand tools, so you won’t have to
sacrifice your hand to make a successful crimp. We’ve researched the tool
components to provide maximum comfort to the operator while ensuring
a complete crimp.
Just wrap your hands around our Comfort Crimp®terminal tool. It’s such
a relief you won’t want to handle any other tool ever again.
For easy visual
verification of crimps,
integrity dots are
embossed on the top
and bottom of the
terminal.
Toggle action increases mechanical
gain, which dramatically reduces
handle force — and the stress on
your hands.
Advanced ergonomic
design of handle
distributes the force
more evenly across
the hand.
Rubberized thermoplastic
handle combines maximum
friction with a soft,
comfortable feel that
reduces muscle tension.
Shure-Stake®
mechanism helps
to ensure a complete
crimp cycle before
it releases the tool.
Color-coded die nests
on both the right and
left sides of the tool
are included for
insulated terminals.
Ergonomically designed handles let user get a grip on safety.
Comfort Crimp®Terminal Tool
ERG-2001
ON BOTH SIDES
Terminal locator
(22–18) A Nest
(16–14) B Nest
(12–10) C Nest
Installs nylon and vinyl insulated terminals, disconnects, and splices
22–10/22–14 AWG
The force required to release the Shure-Stake®mechanism should be
no less than 15 lbs.
Shure-Stake®release on both sides
PUSH
Installs Non-Insulated Terminals #8–1/0 AWG
UL®Listed crimp per UL standard 486C on tubular
D-, E-, F-, G-, and H-style Sta-Kon®Terminals
STD.
CAT. NO. DESCRIPTION PKG.
ERG-2001 RA, RB, RC Nylon & vinyl terminals, splices & disconnects 1
ERG-2002 A, B, C Non-insulated terminals, splices, disconnects 1
ERG-2004 C and C Flag terminal AB Flag terminal and A, B, C 1
non-insulated terminals, splices, disconnects
ERG-2005 B, C, D Non-insulated terminals, splices, 1
(D tubular only) & E (tubular only)
ERG-2007 RD & RE Insulated terminals (Except Brazed Seam) 1
ERG-2008 Non-insulated terminals #8–1/0 AWG
Tool Gauging Requirements
GAUGING
CAT. NO. NEST MIN.–MAX.
ERG-2001 RA .100–.106
RB .116–.124
RC .148–.156
ERG-2002 A .062–.067
B .084–.089
C .110–.115
ERG-2004 AB .062–.067
C .110–.115
ERG-2005 B .082–.090
C .117–.125
D .145–.153
ERG-2007 8 (RED) .190–.196
6 (BLUE) .212–.218
ERG-2008 Self-Contained 8–1/0 AWG
Rotating Die
Gauges available from T&B Tool Service.
ERG-2001
GAUGING
NEST MIN.–MAX.
Red .100–.106
Blue .116–.124
Yellow .148–.156
ERG-2002
GAUGING
NEST MIN.–MAX.
A .067–.062
B .089–.084
C .115–.110
STA-KON
®
CAT. NO. ERG-2002
(12–10) C Nest
(16–14) B Nest
(22–18) A Nest
Installs non-insulated terminals, disconnects, and splices 22–10 AWG
The force required to release the Shure-Stake®mechanism should be
no less than 15 lbs.
Shure-Stake®release on both sides
ERG-2008
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-36
www.tnb.com
Application Tools
Terminal Products and Tools
Terminal Products and Tools
WT145A Rachet Hand Tool
GO. NO GO
GAGE
LOCATOR
Locator
Go, No-Go
Gauge
WT145C Rachet Hand Tool
Installs RA, RB, RC nylon and vinyl terminals, disconnects, and splices.
NW80 SERIES TERMINALS
SEE GAGING TABLES
0 SERIES TERMINALS
GAGING TABLES
NW80
NW50
NW20
NON-INSULATING.
DO NOT CRIMP
ENERGIZED WIRES.
NW80 series terminals
gauging .064–.069
Caution: Handles are non-insulating.
Do not crimp energized wires.
Shure-Stake®mechanism
release opposite side
Installs NW series heater wire terminals.
WT1377 Rachet Hand Tool
Features Shure-Stake®mechanism
Use front nest to install NW18 series terminals,
NW20 series terminals, NW22 series terminals,
and NW50 series terminals
Use rear nest to install NW10 series terminals,
NW14 series terminals, NW80 series terminals,
and 675-14716 series terminals
UPPER NEST
LOWER NEST
ABECFSDJ LJSALSDKL JKSDA
ASDFJJAFLL KLKLJ
CAT. NO. DESCRIPTION STD. PKG
WT145A RA, RAX, RB, RBC, RC, RAA, 1
RBB, RBC, RCC nylon terminal
Features Shure-Stake®mechanism
With the “Lower” gauge (683-G-398) placed into
the rectangular side of the lower nest, the force
required to release the Shure-Stake®mechanism
should be 10–40 lbs.
Features Shure-Stake®mechanism
Force required to release the Shure-Stake®
mechanism should be 10 lbs. minimum
CAT. NO. DESCRIPTION STD. PKG
WT145C RA, RB, RC, RAA, RBB, RCC, 1
RBC nylon and vinyl terminals,
splices, and disconnects
NW20, NW50 series terminals
gauging .047–.054
GAUGING
NEST MIN.–MAX.
Upper .097–.106
Lower .121–.128
GAUGING
NEST MIN.–MAX.
Upper .118–.122
Lower .169–.173
UPPER
NEST
LOCATOR
SCREW
LOAD
BAR
LOAD
BAR
Locator
Upper Nest
Go, No-Go Gauge
Load
Bar
Lower
Nest
Installs RA, RB, RBC, RC nylon terminals.
Upper Nest Lower Nest
Correct compression every time — the Shure-Stake®mechanism
principle prevents opening of the handles until full staking action
is completed. Installs self-insulated and non-insulated Sta-Kon®
terminal series in the #26–10 AWG wire range.
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
CAT. NO. DESCRIPTION STD. PKG
WT1377 NW Ring Terminals 1
C-37
www.tnb.com
Application Tools
Terminal Products and Tools
Terminal Products and Tools
Installs RZ, RV terminals (26–22 AWG wire) and splices.
#26-#22
GAGING
BT
GAGING
Thomas & Betts
WT1452
#26–#22
Gauging
BT
Gauging
CAT. NO. DESCRIPTION STD. PKG
WT1452 Installs RZ, RV Terminals/Splices 1
WT1452 Ratchet Hand Tool
WT465 Ratchet Hand Tool
MIN. GAUGE MAX. GAUGE
NEST “GO” “NO-GO”
BT .039 .049
RZ, RV #26-#22 .063 .073
GAUGING
NEST MIN.–MAX.
22–18 .098–.086
16–14 .113–.101
12–10 .161–.149
CAT. NO. DESCRIPTION STD. PKG
WT1255 RA, RB, RC Heat-Shrinkable nylon 1
insulated terminals, butt splices, and disconnects
22-16
16-14
12-10
WT1255
Installs RA, RB, RC heat-shrinkable nylon insulated
terminals, butt splices, and disconnects.
Pre-load 35–45 lbs.
CAT. NO. DESCRIPTION STD. PKG
WT2130A RC, RBC, and RD insulated 1
terminal #14–#8
CAT. NO. WT2130A
FOR INSTALLING SELF-INSULATED
STA-KON
®
TERMINALS ON COPPER WIRE
NON-INSULATING GRIP
THOMAS & BETTS CORPORATION
12-10
Installs RBC, RC, RD, Sta-Kon®terminals, and RC6 and RP7 wire joints.
WT2130A Rachet Hand Tool
Features Shure-Stake®mechanism
The force required to release the Shure-Stake®
mechanism should be 20 lbs. minimum.
GAUGING
NEST MIN.–MAX.
12–10 .147–.157
8 .185–.195
Pre-load requirement: 20–50 lbs.
Ergonomic design
WT1255 Ratchet Hand Tool
FORCE
FORCE
1 3/4
N9 N9
N1 A
N9 N9
N1
Force
Force
134"
A
.116
.112
.102
.098
.032
.078
.098
.094
.102
.098
.116
.112
.032
.078
.098
.094
CAT. NO. DESCRIPTION STD. PKG
WT465 RA, RB .110 insulated disconnects 1
Conductor
Crimp Area
Stripping Length:
Red & Blue = 14", Yellow = 1132"Stripping Wire
Installs .110 RA, RB disconnects.
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-38
www.tnb.com
Application Tools
Terminal Products and Tools
Terminal Products and Tools
Installation and Gauging Procedure — Adjustable Crimper
Gauging Procedure
1. Close the tool jaws until they bottom.
2. Select the side of tool to be gauged (Tubular or Brazed seam)
3. Move indentor until the pointer slot aligns (clicks) with the selected cable size: For brazed seam
connector, use 6 AWG. For tubular connectors, use 2/0.
4. Gauge the crimping area with a suitable pin gauge. The gauge diameter must fall within
.4056010 tubular and .2156.010 for 6 AWG. brazed product.
Checking Handle Pre-load
1. Lay the tool on a flat surface as shown. Open handle and release it so that it will close of its own
weight.
2. Measure the handle spread distance at the inner surface of the handle tips as shown.
3. If the distance is 14"±12", the tool is adjusted properly. If not, the tool should be adjusted.
Pre-load Adjustment Procedure
1. Turn Adjustment screw clockwise to increase handle spread and counterclockwise to decrease
handle spread.
Installs 8 AWG to 250 MCM non-insulated Sta-Kon®terminals.
WT3185 Ratchet Hand Tool
STD. WT.
CAT. NO. FOR USE WITH STA-KON®SERIES PKG. EACH
WT3185 For 8 AWG to 250 MCM Non-Insulated Sta-Kon®Terminals 1 ????? lbs.
STD. WT.
CAT. NO. FOR USE WITH STA-KON®SERIES PKG. EACH
TBM60RS D thru M (Uninsulated Terminals) 1 6lbs.
RD thru RM (Insulated Terminals)
For more information, see page C??.
Installs D thru M (uninsulated terminals),
and RD thru RM (insulated terminals).
TBM60RS Short Handle Ratchet Tool
Gauging Procedure
1. Ratchet handles until jaws are fully closed.
2. Insert GO, NO-GO gauge into nest. GO gauge should enter freely.
NO-GO gauge should not enter.
D.E.F.G. NESTS
NEST GAGING
D .138 ± .005
E .170 ± .005
F .192 ± .005
G .222 ± .005
D, E, F, G Nests
CAT. NO. DESCRIPTION STD. PKG.
WT129 D, E, F, & G Non-Insulated Flag Terminals 1
Installs Sta-Kon®terminals series D, E, F,
and G flag terminals.
WT129 Flag Terminal Type Hand Tool
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
Cable
Size Line
Adjustment
Screw
Connector
14" x 12"
Indentor
Pointer
Slot
Type of
Connector
Nest
C-39
www.tnb.com
Application Tools
Terminal Products and Tools
Terminal Products and Tools
STD. WT.
CAT. NO. FOR USE WITH STA-KON®SERIES PKG. EACH
WT115A D, E, F, & G Non-Insulated Terminals 1 4lbs.
DOWEL PIN
FRAME
HANDLE
DOWEL PIN
DOWEL PIN INDENTOR
Installs Sta-Kon®terminals
series D, E, F, and G.
WT115A Toggle-Type Hand Tools
GAGING
Gaging
Installing Dies for Non-Insulated Code and Aircraft
Sta-Kon
®
Terminals
CAT. NO.
NEST INDENTOR
STATIONARY MOVABLE TERM. GAUGING
DIE DIE SIZE ± .010
11803 D .152
11803 E (Tubular) .152
11805 E (Brazed), F (Tubular) .167
11806 11802 F (Brazed), G .206
11807 H .234
11808 J .272
11809 K .250
11810 L .266
11811 M .312
Installing Dies for Nylon Insulated Sta-Kon
®
Terminals
TBM6 & TM6S Tool
CAT. NO. TERM. GAUGING
DIE SET SIZE ± .010
11821 RD .170
11822 RE .202
11823 RF .254
11824 RG .321
11825 RH .339
11826 RJ .370
11827 RK .382
11828 RL .456
11829 RM .554
LOWER DIE
UPPER DIE
MOVABLE JAW
TOOL HEAD
TBM6, TBM6S
Installs D–M non-insulated terminals and
splices, and RD–RM nylon insulated terminals
and splices.
TBM6 & TBM6S Toggle-Type Hand Tools
TBM6
STD. WT.
CAT. NO. FOR USE WITH STA-KON®SERIES PKG. EACH
TBM6 D thru M (Dies not included) RD thru RM 1 9lbs.
TBM6S D thru M (Dies not included) RD thru RM with Shure-Stake®1 9lbs.
NEST GAUGING
D .138 ± .005
E .170 ± .005
F .192 ± .005
G .222 ± .005
Directions:
Close handles until lower die touches upper die.
Measure distance between ends of handles.
Distance must be 11" min. and 14" max.
If it is less than 11" or more than 14",
the tool needs to be adjusted.
GAGING
INDENTOR
NEST
Nest
Indentor Gaging
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-40
www.tnb.com
Terminal Products and Tools
Terminal Products and Tools
Gauging
Gauging
Insulated Terminals
Non-Insulated Terminals
STD.
CAT. NO. DESCRIPTION PKG.
12050 Compact, pneumatically operated unit for crimping tape-mounted STA-KON®terminals; 1
equipped with a Shure-Stake®mechanism, which ensures a full compression each time
Space Requirement: 30" W x 20" H x 20" D
Weight: 55 lbs.
Wire Range: #26–#10 AWG
Air Pressure: 90–125 psi input air supply
Installing Dies for 12050
MAX.
STA-KON®AWG DIE GAUGING INSUL.
TERMINAL TYPE WIRE SIZE CAT. NO. MIN.-MAX. DIA.
RA — Nylon 22–18 12051 .108/.114 .136
RA — Vinyl 12054* .117/.121 .150
RB — Nylon 16–14 12052 .133/.139 .162
RB — Vinyl 12055* .122/.126 .170
RC — Nylon and 12–10 12056 .149/.157 .210
Vinyl Insulated
A — Non-Insulated 22–18 12057 .061/.068
B — Non-Insulated 16–14 12058 .083/.090
C — Non-Insulated 12–10 12059 .126/.134
C Disconnect, Non-Insul. 12–10 12060 .103/.111
RV — RZ 26–24 683-54335 .075/.081
*Can also be used on nylon.
RA Series requires a 12061 Die. RB Series requires a 12062 Die.
12050
Crimping tape-mounted STA-KON®terminals.
Wire Range — #26–#10 AWG.
Safe, fast, high-volume crimping machine!
Shure-Stake®mechanism
Fully guarded foot pedal
Clear plastic safety guard over die area
Dies color coded to terminals
#26–10 AWG wire range
Compact, pneumatically operated unit
Installs insulated and non-insulated
terminals and disconnects
Shure-Stake®Auto-Feed Tool
Application Tools
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-41
www.tnb.com
Terminal Products and Tools
Terminal Products and Tools
Interchangeable dies can
be quickly changed to crimp
non-insulated and insulated
terminals up to 6 AWG
Dies are the same as our hand
tools — crimps will be exactly
the same between Sta-Kon®
hand tools such as our ERG-
2001 and the new BAT22-6
360° rotating head gives
the user the added flexibility
when crimping hard-to-reach
connections
Short cycle time equates to
crimping times of less than
two seconds
Quick, lightweight,
and maneuverable
NiCd battery operation provides
long-lasting battery life to
complete up to 150 crimps
on a single charge
Extra battery and charger are
included with the tool, ensuring
round-the-clock operation
Battery charger provides full
battery life in under an hour
Linear crimping motion gives a
symmetric, high-quality crimp
every time
Battery-Powered Crimping Tool —
BAT22-6
112tons of grip that weighs less than
3 pounds!
Crimping Force 2,900 lbs. max.
Crimp Cycle Time — 2 seconds
Wire Crimping Range — Up to 6 AWG
Power Supply — 9.6V NiCd battery
Recharging Time — 1 hour
Crimps per Charge — 150
Dimensions
25.4" (645 mm) Length
3.1" (79 mm) Width
2.1" (53 mm) Height
Tool Weight (With Battery) — 234lbs.
CAT. NO. DESCRIPTION
BAT22-6 Battery Crimping Tool, 1.5 Ton with 120 VAC Charger
Crimp Dies*
DIE2001 Insulated 22–10 AWG Sta-Kon Terminals
DIE2002 Non-Insulated 22–10 AWG Sta-Kon and Spec-Kon Terminals
DIE2005 16–14/12–10/8–6 (Tubular Only) Sta Kon Terminals
DIE2007 Insulated 8–6 AWG Sta-Kon Terminals
Tool purchase includes crimping tool, two 9V batteries, charger, and case.
*Dies sold separately.
. . . . Specifications . . . .
T&B’s newest battery-powered tool is fast and portable for making high-
volume and difficult-to-reach terminal installations in a snap. The Sta-Kon®
BAT22-6 delivers 1.5 tons of crimping force with an easy, pushbutton
trigger. The lightweight, ergonomic design minimizes the
risk of repetitive motion injuries that can occur with
traditional hand crimping tools. And at less than
three pounds, one-hand operation is easy while
still packing enough power to crimp up to
6 AWG terminals in seconds.
Included Accessories
Sturdy, plastic carrying case for portability
Two 9.6V NiCd batteries and battery charger
Sturdy tray for convenient storage of crimp dies
Uses the exact dies
of the Comfort Crimp line
of ergonomic tools for
Sta-Kon, Spec-Kon,
and Dragon Tooth.
Easy to rotate with your
wrist — delivers fast and
effective crimping power.
Application Tools
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-42
www.tnb.com
Terminal Products and Tools
Terminal Products and Tools
CAT. NO. DESCRIPTION STD. PKG.
BAIR22-6 Heavy-duty, high-speed production tool installs a wide range 1
of Sta-Kon®terminals, from 26-6 gauge; uses the ERG 2000
series dies for both non-insulated and insulated terminals;
is supplied complete with foot pedal, air hose-air/lubricator
Crimp Dies*
DIE2001 Insulated 22–10 AWG Sta-Kon Terminals
DIE2002 Non-Insulated 22–10 AWG Sta-Kon and Spec-Kon Terminals
DIE2005 16–14/12–10/8–6 (Tubular Only) Sta-Kon Terminals
DIE2007 Insulated 8–6 AWG Sta-Kon Terminals
Tool purchase includes crimping tool, two 9V batteries, charger, and case.
*Dies sold separately.
NOTE: The dies for the BAIR22-6, PAIR22-6, and the BATT22-6 (page C-41)
are interchangeable.
CAT. NO. DESCRIPTION
PAIR22-6 Open yoke; hand actuated
Crimp Dies*
DIE2001 Insulated 22–10 AWG Sta-Kon Terminals
DIE2002 Non-Insulated 22–10 AWG Sta-Kon and Spec-Kon Terminals
DIE2005 16–14/12–10/8–6 (Tubular Only) Sta-Kon Terminals
DIE2007 Insulated 8–6 AWG Sta-Kon Terminals
Tool purchase includes crimping tool, two 9V batteries, charger, and case.
*Dies sold separately.
Cat. No. 11913 air hose not included.
NOTE: The dies for the BAIR22-6, PAIR22-6, and the BATT22-6 (page C-41) are
interchangeable.
Crimps 22-6 AWG terminals
Portable heavy-duty air tool
Installs Sta-Kon®and Spec-Kon®terminals as well as
ferrules and Dragon Tooth®
Interchangeable dies
Open yoke enables easy access to insert and remove
terminals for crimping
Crimp 22–6 AWG terminals!
1.5 tons of portable grip!
Application Tools
Air Operated — Bench Mounted Tools
Portable Air Hydraulic Tool
1.5 tons of grip
Bench-mounted heavy-
duty air tool
Short cycle time
Shure Stake®mechanism
Foot actuated
Accepts T&B standard
hand tool dies
Installs Sta-Kon®and
Spec-Kon®terminals as
well as ferrules and
Dragon Tooth®
Sta-Kon®terminals, insulated
and non-insulated #22 thru #6
wire range.
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-43
www.tnb.com
Terminal Products and Tools
Terminal Products and Tools
GAGING
GAGING
Nest
Indentor Gauging
Gauging
Installing Dies
for Non-Insulated
Code and Aircraft
Sta-Kon®Terminals
for 25000 Tool
CAT. NO. CAT. NO.
NEST INDENTOR
STATIONARY MOVABLE TERM. GAUGING
DIE DIE SIZE ±.010
11803 D .152
11803 E .152
11805 F .167
11806 11802 G .206
11807 H .234
11808 J .272
11809 K .250
11810 L .266
11811 M .312
Installing Dies
for Nylon Insulated
Sta-Kon®Terminals
for 25000 Tool
CAT. NO. TERM. GAUGING
DIE SET SIZE ±.010
11821 RD .170
11822 RE .202
11823 RF .254
11824 RG .321
11825 RH .339
11826 RJ .370
11827 RK .382
11828 RL .456
11829 RM .554
No more undercrimping!
Air Operated —
Bench Mounted Tools
Convenience and Economy
The tool accepts a full range of interchangeable dies, the same as used
in the TBM6 or 6S tools. To install the dies, simply pull the spring-loaded
pin and remove the indentor die. Then, flex the retaining spring and
remove the die nest.
Shure-Stake®Mechanism Means Quality Connections
The Shure-Stake®mechanism senses inlet air pressure, and if
insufficient, is designed to prevent the tool from cycling.
Thus you avoid “undercrimping.” An 85–90 psi air pressure
source is required.
Safety Features Increase Productivity,
Reduce Downtime
Safety features include a guard over the die area, an air
shutdown switch activated by a slight push with the finger,
and an enclosed foot pedal designed to prevent unwanted
tool operation. In additiion, the tool may be bench-
mounted for stability and control. For convenience when
crimping large size terminals on heavy wire, the head
assembly may overhang the workbench.
Application Tools
CAT. NO. DESCRIPTION STD. PKG.
25000 This compact heavy-duty air tool installs nylon 1
and Tefzel®insulated Sta-Kon®terminals on wire
sizes from 8 AWG to 250 MCM; non-insulated styles
are also installed just as quickly and dependably;
to crimp a terminal, you simply insert the stripped wire
into the terminal barrel, position it in the crimping nest,
and depress the foot pedal, actuating the crimping dies
— it’s that easy
Tefzel®is a registered trademark of DuPont.
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-44
www.tnb.com
Application Tools
Terminal Products and Tools
Terminal Products and Tools
Twelve Ton Crimping Tool
CAT. NO. DESCRIPTION STD. PKG.
13400 Twelve ton crimping tool for installing both insulated and non-insulated Sta-Kon®terminals 1
#8 to 250 MCM (dies ordered separately)
FORGED
STEEL
13400
Installs insulated and non-insulated
Sta Kon® Terminals!
Heavy duty and high-flow rate!
CAT. NO. DESCRIPTION
13810 Electric hydraulic pump, 10,000 psi with Shure-Stake®mechanism
feature; this is a heavy-duty OEM pump with high flow rate; 115V,
60Hz, 112HP, 23A; requires hand or foot control.
You may also need…
13611 Hand Switch for 13810
13612 Foot Switch for 13810
13613 High-Pressure, Steel-Reinforced Hydraulic Hose; 6 ft.
13614 High-Pressure, Steel-Reinforced Hydraulic Hose; 10 ft.
13619 High-Pressure, Plastic Hydraulic Hose; 10 ft.
13600 This electric hydraulic pump is for use with all T&B hydraulic
heads — consists of pump with pressure gauge and Pioneer type
male coupler; add suffix WG to eliminate gauge; output pressure
9,800 psi; order switch and hose separately.
You may also need…
13620 Hand Switch — 10 ft.
13589A Foot Switch — 10 ft.
13619 10-ft. Non-Metallic Hose
13618 20-ft. Non-Metallic Hose
A remote control switch is required. Order Cat. No. 13620 for hand operation
or Cat. No. 13589A for foot operation.
All pumps are supplied with a metal carrying case.
13610A Shure-Stake®electric hydraulic pump has same features as 13600,
but includes the Shure-Stake®control mechanism; prevents under-
crimping; (pump pressure must reach 9,800 psi before recycling);
requires hand or foot control; order switch and hose separately.
You may also need…
13611 Hand Switch — 10 ft.
13612 Foot Switch — 10 ft.
13797 In-line hydraulic pressure inspection gauge with male and female
pioneer-type coupler.
A remote control switch is required to operate this unit. Use either a #13611 (hand)
or #13612 (foot) switch.
13810
13610A
Electric
Hydraulic
Pump
Up to 10,000 psi
output pressure
Durable
construction
Hand or foot
actuated
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-45
www.tnb.com
Application Tools
Terminal Products and Tools
Terminal Products and Tools
13642M
A
Military listed and 12 tons of crimping power!
AN-WIRE SIZE IS ENGRAVED
ON THIS SURFACE
2" REF.
COLOR CODE
IN COUNTERBORE
1-29/32"
REF. A
CAT. NO.
STAMPED ON
BOTH HALVES
Twelve Tons Crimping Tool (Military Spec. MS25441-1)
CAT. NO. DESCRIPTION STD. PKG.
13642M Hydraulic operated 12 to press installs “D” size through “M” size Sta-Kon®1
terminals on “AN” copper wire
DIE CAT. NO
FOR FOR HEX
TUBULAR BRAZED STA-KON®WIRE DIE A
TERM SEAM SIZE SIZE CODE GAUGING
11732 — D 8 21 .197 ± .005
11733 24 .228 ± .005
11733 — E 6 24 .228 ± .005
11734 29 .288 ± .005
11734 – F 4 29 .288 ± .005
11735 33 .332 ± .005
11736 — G 2-1 37 .376 ± .005
11737 — H 1/0 42 .415 ± .005
11738 — J 2/0 45 .453 ± .005
11739 — K 3/0 50 .500 ± .005
11740 — L 4/0 54 .544 ± .009
11771 — M 250 MCM 62 .623 ± .004
Installing Dies for Insulated Terminals
to Fit 13642M (Military Listed) Hex Dies for 13642M (Military Listed)
Gauging for Installing Dies Used to Install
Flag Type Sta-Kon®Terminals — Use with
13642M and 13400
Nest and Indentor for Installing One Piece —
Non-Insulated Terminals to Fit 13642M
and 13400
** Cat. Nos. 21739, 21740, and 21741 dies must be left
in 13642 head with 21732 indentor when gauging.
Nest and Indentors for Installing Sta-Kon®
Brazed Seam Type Non-insulated Terminals
to Fit 13642M and 13400
DIE STA-KON®WIRE A
CAT. NO. SIZE SIZE GAUGING
11781M D 8AN .208 –.212
11782M E 6AN .238 –.242
11783M F 4AN .297 –.301
11784M G 2AN .375 –.379
11785M H 1AN .415 –.419
11786M J 1/0AN .454 –.458
11787M K 2/0AN .488 –.502
11788M L 3/0AN .560 –.564
11789M M 4/0AN .616 –.620
INDENTOR NEST A TERMINAL
CAT. NO. CAT. NO. GAUGING SERIES
13650 13654 .202–.210 G
13650 13655 .230–.238 H
13650 13656 .268–.276 J
13650 13657 .246–.254 K
13650 13658 .262–.270 L
13650 13659 .308–.316 M
NEST INDENT. STA-KON®CODE
CAT. NO. CAT. NO. SIZE WIRE DIA.
13643 D 8 .153/.161
13644 13650 E 6 .183/.191
13645 F 4 .214/.222
NEST INDENTOR STA-KON®GAUGE
CAT. NO. CAT. NO. SIZE MIN. MAX.
21733 8 .147 .153
21734 21731 6 .171 .177
21735 4 .194 .200
21736 2 .262 .269
21737 1 .278 .284
21738 21732 1/0 .309 .315
21739** 2/0 .356 .362
21740** 3/0 .382 .388
21741** 4/0 .434 .440
CAT. NO. A GAUGING STA-KON SIZE
21707M .168 –.172 RD
21708M .200 –.204 RE
21709M .252 –.256 RF
21710M .310 –.314 RG
21711M .337 –.341 RH
21712M .368 –.372 RJ
21713M .406 –.402 RK
21714M .436 –.440 RL
21715M .471 –.475 RM
Hex dies for 13642M and 13400
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-46
www.tnb.com
Tool Charts
Terminal Products and Tools
Terminal Products and Tools
Select the die numbers you need!
TOOL PLIERS RACHET ERGONOMIC
HAND TOOLS
DESCRIPTION TERMINAL SERIES WT110M WT111M WT112M WT161M WT2000 ERG-2001 ERG-2002 ERG-2004 ERG-2005 WT1377
RZZ
Nylon RA, RAX ••
Terminal RB, ••
RBC, RC ••
Nylon/ RA ••
Butt Splice RB ••
RC ••
Nylon/ RAA
Parallel Splices RBB
RCC
Nylon Disconnect/ RA ••
Fully Insul. Disconnects RB ••
(except 110 Disconnects RC ••
Heat-Shrinkable RAS
Nylon Terminal, RBS
Butt Splice, Disconnects RCS
Vinyl Terminal, RA, RAA ••
Splices RB, RBB ••
RC, RCC, RBC ••
Bare Terminal, A, AA •••••
Splices B, BB •••••
C, CC •••••
RB
Wire RC ••
Joints RP ••
PT ••
Hi-Temp Terminals NW-Rings
NW-Splice
Insulation Grip A
B
110 Disconnects A, B •••
RA, RB
Flag Terminal AB
C
Tefzel®Terminal RAT, RBT, RCT
Vinyl RA •••
Disconnects RB •••
RC ••
Bare A••••• ••
Disconnects B•••••
C••••• •••
Tefzel®RAAT ••
Butt Splices RBBT ••
RCCT ••
Tefzel®is a registered trademark of DuPont.
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-47
www.tnb.com
Tool Charts
Terminal Products and Tools
Terminal Products and Tools
BATT 22-6
BAIR 22-6
RACHET HAND TOOLS 12050 DIE NUMBERS PAIR 22-6
11901A – 11904A
13500 DIE NUMBERS
WT145A WT145C WT1452 WT465 WT1255 WT2130A 12051 12052 12054 12055 12056 12057 12058 12059 12060 11951 2001 2002 2005 2007
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-48
www.tnb.com
Tool Charts
Terminal Products and Tools
Terminal Products and Tools
25000 AIR TOOL 13642M (MS25441-1)
HAND TBM6 — TOGGLE HAND TOOL AND
TOOL TBM6S — TOGGLE HAND TOOL 13400 HYDRAULIC TOOL
TERMINAL WITH DIE CAT. NOS. HEX
DESCRIPTION SERIES TYPE DIES NEST (STATIONARY) INDENTOR (MOVABLE) DIES NEST INDENTOR
D Tubular ERG2005 11803 11802 11781M*13651 13650**
D Tubular ERG2008 11803 11802 11781M* 13651 13650**
D Tubular WT3185 11803 11802 11732 13651 13650**
D Brazed WT3185 11803 11802 11733 13652 13650**
E Tubular ERG2005 11803 11802 11733 13652 13650**
E Tubular ERG2008 11803 11802 11733 13652 13650**
E Tubular WT3185 11803 11802 11782M*13652 13650**
E Brazed WT3185 11805 11802 11734 13653 13650**
F Tubular ERG2008 11805 11802 11734 13653 13650**
F Tubular WT3185 11805 11802 11783M* 13653 13650**
F Brazed WT3185 11806 11802 11735 13645 13650**
G Tubular ERG2008 11806 11802 11784M*/11736 13654 13650**
G Tubular WT3185 11806 11802 11784M*/11736 13654 13650**
H Tubular ERG2008 11807 11802 11785M* 13655 13650**
H Tubular WT3185 11807 11802 11785M*13655 13650**
H Tubular WT3185 11807 11802 11737 13655 13650**
J Tubular WT3185 11808 11802 11786M*13656 13650**
J Tubular WT3185 11808 11802 11738 13656 13650**
K Tubular 11809 11802 11787M*13657 13650**
K Tubular 11809 11802 11739 13657 13650**
L Tubular 11810 11802 11788M*13658 13650**
L Tubular 11810 11802 11740 13658 13650**
M Tubular 11811 11802 11789M*13659 13650**
M Tubular 11811 11802 11771 13659 13650**
RD Tubular ERG2007 11821 (Set) 21707M* (Set)
RD Brazed 11822 (Set) 21708M* (Set)
RE Tubular ERG2007 11822 (Set) 21708M* (Set)
RE Brazed 11823 (Set) 21709M* (Set)
RF Tubular 11823 (Set) 21709M* (Set)
RF Brazed 11824 (Set) 21710M* (Set)
RG Tubular 11824 (Set) 21710M* (Set)
RH Tubular 11825 (Set) 21711M* (Set)
RJ Tubular 11826 (Set) 21712M* (Set)
RK Tubular 11827 (Set) 21713M* (Set)
RL Tubular 11828 (Set) 21714M* (Set)
RM Tubular 11829 (Set) 21715M* (Set)
D— WT129 ——21733 21731
E— WT129 ——21734 21731
F— WT129 ——21735 21731
G— WT129 ——21736 21732
H— 21737 21732
J— 21738 21732
K— 21739 21732
L— 21740 21732
M— 21741 21732
* Indicates military listed die.
** To order the military version, suffix the indentor catalog number with an "M" (13650M). Nest catalog number does not change.
Tefzel®is a registered trademark of DuPont.
Stud Size and Clearance Hole Chart
STUD SIZE 2 4 6 8 10 14516 38716 125834
Min. hole diam. — in. 0.92 .116 .143 .169 .196 .262 .323 .388 .453 .516 .650 .775
Min. hole diam. — mm 2.337 2.946 3.632 4.292 4.978 6.655 8.204 9.855 11.506 13.106 16.510 19.685
Critical information for determining the products you need!
Non-Insulated
Terminals
and Splices
Tefzel®† Nylon
Insulated Terminals
and Splices
Non-Insulated
Flag Terminals
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-49
www.tnb.com
Terminal Products and Tools
Terminal Products and Tools
NAVY INDIVIDUAL STRANDS WHOLE CONDUCTOR
AWG OR AN SHIPBOARD3NO. DIAM. IN. CIR. MIL. AREA DIAM. IN. DIAM. MM
22 Wire Size
22 3/5 (1) 1 .025 642 .025 .635
22 3/5 (7) 7 .010 703 .030 .762
AN-22* 7 * 704 .032 .813
12(21) 21 .005 525 .028 .711
20 Wire Size
20 1 (1) 1 .032 1,022 .032 .813
20 7 .012 1,024 .036 .914
20 10 .010 1,005 .040 1.016
20 19 .007 1,022 .037 .940
20 26 .006 1,034 .039 .991
AN-20* 7 * 1,119 .040 1.016
1 (7) 7 .013 1,119 .038 .965
1 (10) 10 .010 1,005 .038 .965
1 (26) 26 .006 1,034 .042 1.067
18 Wire Size
18 112(1) 1 .040 1,624 .040 1.016
18 112(7) 7 .016 1,624 .049 1.245
18 112(16) 16 .010 1,608 .049 1.245
18 19 .009 1,624 .046 1.168
18 112(41) 41 .006 1,630 .049 1.245
AN-18* 2 (7) 7 .016 1,779 .048 1.219
16 Wire Size
16 212(1) 1 .051 2,583 .051 1.295
16 7 .019 2,583 .058 1.473
16 19 .012 2,601 .058 1.473
16 26 .010 2,613 .059 1.499
16 65 .006 2,580 .058 1.473
AN-16* 212(19) 19 .011 2,407 .061 1.549
212(26) 26 .010 2,613 .061 1.549
14 Wire Size
14 1 .064 4,107 .064 1.626
14 7 .024 4,107 .073 1.854
14 19 .015 4,107 .074 1.880
14 37 .011 4,107 .074 1.880
14 14 .009 4,157 .083 2.108
14 104 .006 4,128 .074 1.880
AN-14* 19 * 3,830 .076 1.930
3 (7) 7 .020 2,828 .060 1.524
3 (19) 19 .013 3,036 .063 1.600
4 (1) 1 .064 4,107 .064 1.626
4 (7) 7 .025 4,497 .076 1.930
4 (19) 19 .014 3,828 .072 1.829
4 (41) 41 .010 4,121 .077 1.956
12 Wire Size
12 1 .081 6,530 .081 2.057
12 7 .031 6,530 .092 2.337
12 19 .019 6,530 .093 2.362
12 37 .013 6,530 .093 2.362
12 49 .012 6,593 .104 2.642
12 65 .010 6,533 .093 2.362
12 104 .008 6,574 .094 2.388
12 165 .006 6,559 .095 2.413
AN-12* 6 (19) 19 .018 6,088 .096 2.438
6 (7) 7 .031 6,512 .092 2.337
6 (65) 65 .010 6,533 .097 2.964
10 Wire Size
10 1 .102 10,380 .102 2.591
10 7 .039 10,380 .116 2.946
10 19 .023 10.380 .117 2.972
10 37 .017 10,443 .117 2.972
10 49 .015 10,445 .131 2.327
10 104 .010 10,452 .116 2.946
AN-10* 37 * 10,380 .117 2.972
9 (7) 7 .036 9,016 .108 2.743
9 (37) 37 .016 9,402 .109 2.769
9 (90) 90 .010 9,045 .120 3.048
* MIL-W-5086. * Strand diameter not specified. 3 MIL-E-16366 A.
Wire Strip
Length Chart
RECOMMEND
WIRE STRIP
LENGTH “A
WIRE STRIP TERMINAL STANDARD
LENGTH SERIES TERMINALS
A14
Non-Insulated B 14
C, BC 516
Vinyl Insulated — RA 14
Add 116" for RB 14
Funnel Entry Type RC, RBC 1132
Nylon Insulated RA 732
and Tefzel®RB 732
Insulated RC, RBC 516
RD 1732
RE 1732
RF 916
Nylon Insulated RG 1116
and Tefzel®RH 1116
Insulated RJ 34
when using RK 78
Aircraft and RL 78
Code Wire RM 1
D1532
E1532
F12
Non-Insulated, G 4164
when using H 4364
Aircraft Code Wire J 4764
K5564
L5564
M5964
Tefzel®is a registered trademark of DuPont.
Non-Insulated
Vinyl Insulated —
Add 116" for
Funnel Entry Type
Nylon Insulated
and Tefzel®
Insulated
Nylon Insulated
and Tefzel®
Insulated
when using
Aircraft and
Code Wire
Non-Insulated,
when using
Aircraft Code Wire
Wire Guide Tables
A
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-50
www.tnb.com
Wire Guide Tables
Terminal Products and Tools
Terminal Products and Tools
NAVY INDIVIDUAL STRANDS WHOLE CONDUCTOR
AWG OR AN SHIPBOARD3NO. DIAM. IN. CIR. MIL. AREA DIAM. IN. DIAM. MM
9 Wire Size
9 7 .043 13,090 .130 3.302
14 (7) 7 .045 14,340 .136 3.454
8 Wire Size
8 7 .049 16,510 .146 3.712
8 19 .030 16,510 .148 3.763
8 37 .021 16,510 .148 3.763
7 Wire Size
7 1 .144 20,820 .144 3.662
14 (7) 7 .045 14,340 .136 3.454
14 (140) 140 .010 14,070 .145 3.787
6 Wire Size
6 7 .061 25,250 .184 4.672
6 19 .037 26,250 .186 4.722
6 37 .027 26,250 .186 4.722
6 49 .023 26,146 .208 5.283
6 661 .006 26,274 .259 6.579
5 Wire Size
5 1 .181 33,100 .181 4.595
20 (49) 7x7 .020 19,800 .180 4.570
23 (7) 7 .057 22,800 .171 4.345
23 (228) 19x12 .010 22,190 .190 4.830
26 (49) 7x7 .023 26,250 .210 5.330
4 Wire Size
4 7 .077 41,740 .232 5.891
4 19 .047 41,740 .235 5.967
4 37 .034 41,740 .235 5.967
3 Wire Size
3 1 .229 52,630 .229 5.819
30 (304) 19x16 .010 30,550 .220 5.590
33 (336) 7x48 .010 33,370 .235 5.967
40 (19) 19 .045 38,910 .226 5.742
42 (49) 7x7 .029 41,740 .260 6.600
42 (209) 19x11 .014 42,110 .260 6.600
50 (19) 19 .051 49,080 254 6.452
2 Wire Size
2 7 .097 66,370 .292 7.421
2 19 .059 66,370 .296 7.522
2 37 .042 66,370 .297 7.548
2 49 .037 66,356 .331 8.405
2 133 .022 66,140 .335 8.507
AN-2* 663 * 66,832 .345 8.767
53 (532) 19x28 .010 53,470 .304 7.772
60 (37) 37 .040 60,090 .282 7.161
60 (304) 19x16 .014 61,260 .310 7.870
66 (133) 19x7 .022 66,370 .330 8.380
75 (37) 37 .045 75,780 .317 8.048
1 Wire Size
1 7 .109 83,690 .328 8.333
1 19 .066 83,690 .332 8.431
1 37 .048 83,690 .333 8.456
1 61 .037 83,690 .333 8.456
1 133 .025 83,690 .377 9.578
1 259 .018 83,916 .378 9.603
AN-1* 812 * 81,807 .384 9.752
83 (418) 19x22 .014 84,230 .380 9.650
84 (2,107) 2107 * 83,690 .410 10.41
* MIL-W-5086.
* Strand diameter not specified.
3 MIL-E-16366 A
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-51
www.tnb.com
Wire Guide Tables
Terminal Products and Tools
Terminal Products and Tools
NAVY INDIVIDUAL STRANDS WHOLE CONDUCTOR
AWG OR AN SHIPBOARD3NO. DIAM. IN. CIR. MIL. AREA DIAM. IN. DIAM. MM
1/0 Wire Size
1/0 7 .123 105,500 .368 9.343
1/0 19 .075 105,500 .373 9.476
1/0 37 .053 105,500 .374 9.502
1/0 61 .042 105,500 .374 9.502
1/0 133 .028 105,761 .423 10.721
1/0 259 .020 105,672 .424 10.772
AN-0* 1,033 * 104,118 .432 10.971
100 (61) 61 .040 99,060 .363 9.216
105 (259) 37x7 * 105,500 .410 10.410
2/0 Wire Size
105 (2,646) 2,646 * 105,500 .460 11.680
2/0 7 .138 133,100 .414 10.512
2/0 19 .084 133,100 .419 10.639
2/0 37 .060 133,100 .420 10.670
2/0 61 .047 133,100 .420 10.670
2/0 133 .032 132,800 .474 12.042
2/0 259 .023 133,462 .477 12.118
AN-00* 1,327 * 133,665 .490 12.450
125 (61) 61 .045 124,900 .407 10.338
133 (259) 37x7 * 133,100 .460 11.680
133 (684) 19x36 .014 137,800 .480 12.190
133 (3,325) 3,325 * 133,100 .520 13.210
150 (61) 61 .051 157,600 .457 11.608
3/0 Wire Size
3/0 7 .155 167,800 .464 11.782
3/0 19 .094 167,800 .470 11.940
3/0 37 .067 167,800 .471 11.965
3/0 61 .052 167,800 .472 11.991
3/0 133 .036 167,607 .533 13.536
3/0 259 .026 167,402 .536 13.612
3/0 4,227 .006 168,023 .610 15.490
150 (760) 19x40 .014 153,100 .510 12.950
168 (427) 61x7 * 167,800 .520 13.210
4/0 Wire Size
4/0 7 .174 211,600 .522 13.261
4/0 19 .106 211,600 .528 13.413
4/0 37 .076 211,600 .529 13.439
4/0 61 .059 211,600 .530 13.460
4/0 133 .040 211,736 .599 15.219
4/0 259 .029 211,845 .601 15.265
AN-000* 1,661 * 167,332 .548 13.923
200 (61) 61 .057 198,700 .514 13.652
200 (988) 19x52 .014 199,100 .580 14.730
250 MCM Wire Size
250,000 19 .115 250,000 .574 14.582
250,000 37 2 250,000 .575 14.607
250,000 61 .064 250,000 .576 14.632
250,000 91 .052 250,000 .576 14.632
AN-0000* 2,104 * 211,954 .615 15.617
220 (259) 37x7 .029 220,700 .610 15.490
250 (61) 61 .064 250,000 .577 14.658
* MIL-W-5086.
* Strand diameter not specified.
3 MIL-E-16366 A.
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-52
www.tnb.com
Teminals Military Standard Cross Reference
Terminal Products and Tools
Terminal Products and Tools
MIL-T-7928 T&B CAT. NO.
MS-25036 CLASS 1 & 2
-101 RA333
-102 RA853
-103 RA873
-104 RA723
-105 RA733
-106 RB1333
-107 RB853
-108 RB873
-109 RB723
-110 RB733
-111 RC333
-112 RC363
-113 RC703
-114 RC733
-115 RD10361
-116 RD10711
-117 RD10721
-118 RD10731
-119 RE10261
-120 RE10711
-121 RE10721
-122 RE10731
-123 RF10711
-124 RF10721
-125 RF10731
-126 RG9711
-127 RG9731
-128 RG9751
-129 RH9711
-130 RH9731
-131 RH9751
-132 RJ9711
-133 RJ9731
-135 RK9721
-136 RK9731
-137 RK9751
-138 RL9731
-139 RL9751
-140 RM9731
-141 RM9751
-142
-143 RAX23
-144 RAX43
-145 RAX63
-146 RAX83
-147 RAX103
-148 RA323
-149 RA863
-150 RA713
-151 RA753
-152 RB1323
-153 RB863
-154 RB713
-155 RB753
-156 RC863
-157 RC713
-158 RC753
MIL-T-22909 T&B
MS-90485 CAT. NO.
-8 11781M
-6 11782M
-4 11783M
-2 11784M
-1 11785M
-01 11786M
-02 11787M
-03 11788M
-04 11789M
MIL-T-7928 T&B
MS-17143 CAT. NO.
-1 RA480
-2 RB480
-3 RC480
-4 RA481
-5 RB481
-6 RC481
-7 RA482
-8 RB482
-9 RC482
-10 RA483
-11 RB483
-12 RC483
-13 RA484
-14 RB484
-15 RC484
-16 RA485
-17 RB485
-19 RA486
-20 RB486
MIL-T-7928 T&B CAT. NO.
MS-20659 CLASS 1 & 2
-101 A85G
-102 A87G
-103 B85G
-104 B87G
-105 C26
-106 C70
-107 D10361
-108 D10721
-109 E10711
-110 E10731
-111 F10711
-112 F10731
-113 G971
-114 G973
-115 H971
-116 H973
-117 J971
-118 J973
-119 K972
-120 K973
-121 L973
-122 L975
-123 M973
-124 M975
-128 C73
-129 D10731
-130 E10261
-131 E10721
-132 F10721
-133 G975
-134 H975
-135 J975
-136 K975
-140 D10161
-141 D10711
-144 F10261
-146 G926
-147 G972
-148 G974
-149 H972
-151 J972
-152 J974
-153 K971
-154 K974
-155 L972
-156 L974
-157 M972
-158 M974
-165 C33
-166 C75
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
MIL-T-7928 T&B
MS-21004 CAT. NO.
-1 A486
-2 A483
-3 A482
-4 A481
-5 A485
-6 A484
-7 A480
-8 B486
-9 B483
-10 B482
-11 B481
-12 B485
-13 B484
-14 B480
-15 C486
-16 C483
-17 C482
-18 C481
-19 C485
-20 C484
-21 C480
MIL-T-22909 T&B
-MS-23002 CAT. NO.
-8 21707M
-6 21708M
-4 21709M
-2 21710M
-1 21711M
-01 21712M
-02 21713M
-03 21714M
-04 21715M
C-53
www.tnb.com
Cross Reference for Packaging
Terminal Products and Tools
Terminal Products and Tools
T&B T&B
DISTRIBUTOR BULK
PACKAGE PACKAGE
A18-6 A85
A18-6F A116
A18-6FL A221
A18-8 A86
A18-8F A114
A18-8FL A224
A18-10 A87
A18-10F A115
A18-10FL A225
A18-12 A75
A18-14 A71
A18-38 A73
A18-110F A10
A18-111F A11
A18-250 A250
A18-250A A252G
A18-251T A251
A18-516 A72
AB14-6A AB51
AB14-8A AB52
AB14-10A AB53
AD18-182 AD182
AD18-183 AD183
B14-D B23
B14-4 B132
B14-6 B133
B14-6F B64
B14-6FL B220
B14-6FS B19
B14-8 B86
B14-8F B65
B14-8FL B223
B14-10 B87
B14-10F B115
B14-10FL B225
B14-10G B87G
B14-12 B75
B14-14 B71
B14-38 B73
B14-110F B10
B14-111F B11
B14-250 B250
B14-250A B252G
B14-250F B250G
B14-250T B251G
B14-251T B251
B14-516 B72
BC14-6 BC85
BC14-8 BC86
BC14-10 BC87
BC14-12 BC75
BC14-14 BC71
BC14-38 BC79
BC14-516 BC72
BD14-183 BD183
C10-6 C33
C10-6A C51
C10-6F C133
C10-6FL C220
C10-8 C77
C10-8A C52
C10-8F C114
C10-8FL C221
C10-10 C26
C10-10A C53
C10-10F C115
C10-10FL C222
C10-12 C75
T&B T&B
DISTRIBUTOR BULK
PACKAGE PACKAGE
RB14-8 RB863
RB14-8F RB1123
RB14-8FL RB2233
RB14-8FS RB1223
RB14-8X RB864
RB14-10 RB873
RB14-10F RB1153
RB14-10FL RB2253
RB14-10FS RB1253
RB14-10X RB874
RB14-12 RB753
RB14-14 RB713
RB14-14F RB1163
RB14-14X RB714
RB14-38 RB733
RB14-38X RB734
RB14-47PT RB147PT
RB14-110F RB10
RB14-111F RB11
RB14-250 RBB250
RB14-250A RB2577F
RB14-250F RB250
RB14-250FP RB250P
RB14-516 RB723
RB14-516X RB724
RB44 RB4
RBC14-14 RBC713
RBC14-516 RBC723
RBD14-182 RBD1823
RBD14-183 RBD1833
RC10-6 RC333
RC10-6F RC1113
RC10-6FL RC2203
RC10-8 RC863
RC10-8F RC1123
RC10-8FL RC2213
RC10-8FS RC1223
RC10-8X RC864
RC10-10 RC363
RC10-10F RC1153
RC10-10FL RC2223
RC10-10FS RC1253
RC10-10X RC364
RC10-12 RC753
RC10-14 RC713
RC10-14F RC1163
RC10-14FL RC2233
RC10-14X RC714
RC10-38 RC733
RC10-38X RC734
RC10-55PT RC155PT
RC10-250A RC2577F
RC10-250F RC250
RC10-516 RC703
RC55 RC6
RD8-10 RD367
RD8-12 RD757
RD8-14 RD717
RD8-38 RD737
RD8-516 RD727
RE6-10 RE267
RE6-12 RE757
RE6-14 RE717
RE6-38 RE737
RE6-516 RE727
RF4-10 RF267
RF4-12 RF757
RF4-14 RF717
T&B T&B
DISTRIBUTOR BULK
PACKAGE PACKAGE
C10-14 C71
C10-14F C116
C10-38 C73
C10-250A C252G
C10-250F C250
C10-516 C70
D8-10 D36
D8-12 D75
D8-14 D71
D8-38 D73
D8-516 D72
E6-10 E26
E6-12 E75
E6-14 E71
E6-38 E73
E6-516 E72
F4-10 F26
F4-12 F75
F4-14 F71
F4-38 F73
F4-516 F72
F250TA FTA250
G2-12 G975
G2-14 G971
G2-38 G973
G2-516 G972
H10-14 H971
J20-38 J973
K30-38 K973
L40-38 L973
M250-38 M973
NW14-6 NW81
NW14-10 NW83
NW14-12 NW84
NW22-10 NW23
RA18D RA23
RA18-4 RA323
RA18-6 RA853
RA18-6F RA1103
RA18-6FL RA2213
RA18-6FS RA1203
RA18-8 RA863
RA18-8F RA1123
RA18-8FL RA2243
RA18-8FS RA1223
RA18-10 RA873
RA18-10F RA1153
RA18-10FL RA2253
RA18-10FS RA1253
RA18-12 RA753
RA18-14 RA713
RA18-14F RA1163
RA18-38 RA733
RA18-47PT RA147PT
RA18-110F RA10
RA18-111F RA11
RA18-250A RA2577F
RA18-250F RA250
RA18-250FP RA250P
RA18-516 RA723
RAD18-182 RAD1823
RAD18-183 RAD1833
RB14-4 RB1323
RB14-6 RB853
RB14-6F RB1113
RB14-6FL RB2213
RB14-6FS RB1203
RB14-6X RB854
NOTE: All catalog numbers do not appear in this cross reference.
This means it may not be available in one of the package options.
T&B T&B
DISTRIBUTOR BULK
PACKAGE PACKAGE
RF4-38 RF737
RF4-516 RF727
RG2-10 RG267
RG2-12 RG757
RG2-14 RG717
RG2-38 RG737
RG2-516 RG727
RP12 RP7
2A-18 AA2
2A20 RAA24
2A22-20 A1A
2B-14 BB2
2B-16 RBB25
2B18-16 B1B
2C-10 CC2
2C-12 RCC26
2C14-12 C1C
2D-8 DD102
2D10-9 D1D
2E-6 EE2
2E8-7 E1E
2F-4 FF2
2F6-5 F1F
2G21 GG2
2G4-2 G1G
2RAA RAA23
2RA18 RAA21
2RA18X RAA217-170
2RBB RBB23
2RB14 RBB21
2RB14X RBB217-200
2RCC RCC23
2RC10 RCC21
2RC10X RCC217-250
2RD8 RDD27
2RE6 REE28
10RC-6 RC337
10RC-6F RC1337
10RC-6FL RC2207
10RC-6FLX RC2207-250
10RC-6X RC337-250
10RC-8 RC777
10RC-8F RC1147
10RC-8FL RC2217
10RC-8FLX RC2217-250
10RC-8X RC777-250
10RC-10 RC367
10RC-10F RC1157
10RC-10FL RC2227
10RC-10FLX RC2227-250
10RC-10FX RC1157-250
10RC-10X RC367-250
10RC-14 RC717
10RC-14F RC1167
10RC-14FL RC2237
10RC-14X RC717-250
10RC-38 RC737
10RC-38X RC737-250
10RC-55PT RC55PT
10RC-250F RC257
10RC-250T RC2517
10RC-251T RC25177
10RC-516 RC707
10RC-2577 RC2573
14RB-4 RB1327
14RB-6 RB857
T&B T&B
DISTRIBUTOR BULK
PACKAGE PACKAGE
14RB-6F RB647
14RB-6FL RB2207
14RB-6FLX RB2207-200
14RB-6FX RB647-200
14RB-6X RB857-200
14RB-8 RB867
14RB-8F RB657
14RB-8FL RB2237
14RB-8FLX RB2237-200
14RB-8FX RB657-200
14RB-8X RB867-200
14RB-10 RB877
14RB-10F RB1157
14RB-10FL RB2257
14RB-10FLX RB2257-200
14RB-10FX RB1157-200
14RB-10X RB877-200
14RB-14 RB717
14RB-14X RB717-200
14RB-38 RB737
14RB-47PT RB47PT
14RB-250F RB257
14RB-250T RB2517
14RB-251T RB25177
14RB-516 RB727
14RB-2577 RB2573
14RBC-6 RBC857
14RBC-8 RBC867
14RBC-10 RBC877
14RBC-14 RBC717
14RBC-516 RBC727
14RBC-38 RBC797
14RBC-12 RBC757
14RBD-182 RBD1827
14RBD-183 RBD1837
14RBD-18277 RBD18277
14RBD-18377 RBD18377
18RA-4 RA77
18RA-6 RA857
18RA-6F RA1167
18RA-6FL RA2217
18RA-6FLX RA2217-170
18RA-6FX RA1167-170
18RA-6X RA857-170
18RA-8 RA867
18RA-8F RA1147
18RA-8FL RA2247
18RA-8FX RA1147-170
18RA-8X RA867-170
18RA-10 RA877
18RA-10F RA1157
18RA-10FL RA2257
18RA-10FLX RA2257-170
18RA-14 RA717
18RA-38 RA737
18RA-47PT RA47PT
18RA-250F RA257
18RA-250T RA2517
18RA-251T RA25177
18RA-516 RA727
18RA-516X RA727-170
18RA-2577 RA2573
18RAD-182 RAD1827
18RAD-183 RAD1837
18RAD-18277 RAD18277
18RAD-18377 RAD18377
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
C-54
www.tnb.com
Cross Reference for Packaging
Terminal Products and Tools
Terminal Products and Tools
T&B T&B
DISTRIBUTOR BULK
PACKAGE PACKAGE
A18-110F A10
A18-111F A11
A18-10F A115
A18-14 A71
A18-14F A71F
A18-12 A75
A18-6 A85
A18-8 A86
A18-10 A87
A18-8F A114
A18-10F A115
A18-6F A116
A18-6FL A221
A18-8FL A224
A18-10FL A225
A18-250 A250
A18-251T A251
A18-250A A252G
2A22-20 A1A
2A18 AA2
AB14-6A AB51
AB14-8A AB52
AB14-10A AB53
AD18-182 AD182
AD18-183 AD183
B14-110F B10
B14-111F B11
B14-D B23
B14-6F B64
B14-8F B65
B14-14 B71
B14-516 B72
B14-38 B73
B14-12 B75
B14-6 B133
B14-8 B86
B14-10 B87
B14-10G B87G
B14-10F B115
B14-4 B132
B14-6FL B220
B14-8FL B223
B14-10FL B225
B14-250 B250
B14-250F B250G
B14-251T B251
B14-250T B251G
B14-250A B252G
2B18-16 B1B
2B14 BB2
BC14-14 BC71
BC14-516 BC72
BC14-12 BC75
BC14-38 BC79
BC14-6 BC85
BC14-8 BC86
BC14-10 BC87
BD14-183 BD183
C10-10 C26
C10-6 C33
C10-8A C52
C10-10 C53
C10-516 AC70
C10-14 C71
C10-38 C73
C10-12 C75
C10-8 C77
C10-8F C114
T&B T&B
DISTRIBUTOR BULK
PACKAGE PACKAGE
18RA-8X RA867-170
RA18-10 RA873
18RA-10 RA877
18RA-10X RA877-170
RA18-6F RA1103
RA18-8F RA1123
18RA-8F RA1147
18RA-8FX RA1147-170
RA18-10F RA1153
18RA-10F RA1157
RA18-14F RA1163
18RA-6F RA1167
18RA-6FX RA1167-170
RA18-6FS RA1203
RA18-8FS RA1223
RA18-10FS RA1253
RA18-6FL RA2213
18RA-6FL RA2217
18RA-6FLX RA2217-170
RA18-8FL RA2243
18RA-8FL RA2247
RA18-10FL RA2253
18RA-10FL RA2257
18RA-10FLX RA2257-170
18RA-250T RA2517
18RA-2577 RA2573
RA18-250A RA2577F
18RA-251T RA25177
2RA18 RAA21
2RAA RAA23
2A20 RAA24
2RA18X RAA217-170
RAD18-182 RAD1823
18RAD-182 RAD1827
RAD18-183 RAD1833
18RAD-183 RAD1837
RAD18-188A RAD1887F
18RAD18277 RAD18277
18RAD18377 RAD18377
RB44 RB4
RB14-110F RB10
RB14-111F RB11
RB14-D RB23
14RB-47PT RB47PT
14RB-6FS RB197
RB14-47PT RB147PT
RB14-250F RB250
RB14-250FP RB250P
14RB-250F RB257
14RB-6F RB647
14RB-6FX RB647-200
14RB-8F RB657
14RB-8FX RB657-200
RB14-14 RB713
RB14-14X RB714
14RB-14 RB717
14RB-14X RB717-200
RB14-516 RB723
RB14-516X RB724
14RB-516 RB727
RB14-38 RB733
RB14-38X RB734
14RB-38 RB737
RB14-12 RB753
RB14-6 RB853
RB14-6X RB854
14RB-6 RB857
14RB-6X RB857-200
T&B T&B
DISTRIBUTOR BULK
PACKAGE PACKAGE
C1010F C115
C10-14F C116
C10-6F C133
C10-6FL C220
C10-8FL C221
C10-10FL C222
C10-250F C250
C10-250A C252G
2C14-12 C1C
2C10 CC2
D8-10 D36
D8-14 D71
D8-516 D72
D8-38 D73
D8-12 D75
2D10-9 D1D
2D8 DD102
E6-10 E26
E6-14 E71
E6-516 E72
E6-38 E73
E6-12 E75
2E8-7 E1E
2.00E+06 EE2
F4-10 F26
F4-14 F71
F4-516 F72
F4-38 F73
F4-12 F75
2F6-5 F1F
2F4 FF2
F250-TA FTA250
G2-14 G971
G2-516 G972
G2-38 G973
G2-12 G975
2G4-2 G1G
2G21 GG2
H10-14 H971
J20-38 J973
K30-38 K973
L40-38 L973
M250-38 M973
NW22-10 NW23
NW14-10 NW83
NW14-12 NW84
RA18-110F RA10
RA18-111F RA11
RA18-D RA23
18RA-47PT RA47PT
18RA-4 RA77
RA18-47PT RA147PT
RA18-250F RA250
RA18-250FP RA250P
18RA-250F RA257
RA18-4 RA323
RA18-14 RA713
18RA-14 RA717
RA18-516 RA723
18RA-516 RA727
RA18-38 RA733
18RA-38 RA737
RA18-12 RA753
RA18-6 RA853
18RA-6 RA857
18RA-6X RA857-170
RA18-8 RA863
18RA-8 RA867
T&B T&B
DISTRIBUTOR BULK
PACKAGE PACKAGE
RB14-8 RB863
RB14-8X RB864
14RB-8 RB867
14RB-8X RB867-200
RB14-10 RB873
RB14-10X RB874
14RB-10 RB877
14RB-10X RB877-200
RB14-6F RB1113
RB14-8F RB1123
RB14-10F RB1153
14RB-10F RB1157
14RB-10FX RB1157-200
RB14-14F RB1163
RB14-6FS RB1203
RB14-8FS RB1223
RB14-10FS RB1253
RB14-4 RB1323
14RB-4 RB1327
14RB-6FL RB2207
14RB-6FLX RB2207-200
RB14-6FL RB2213
RB14-8FL RB2233
14RB-8FL RB2237
14RB-8FLX RB2237-200
RB14-10FL RB2253
14RB-10FL RB2257
14RB-10FLX RB2257-200
14RB-250T RB2517
14RB-2577 RB2573
RB14-250A RB2577F
14RB-251T RB25177
2RB14 RBB21
2RBB RBB23
2B16 RBB25
2RB14X RBB217-200
RB14-250 RBB250
RBC14-14 RBC713
14RBC-14 RBC717
RBC14-516 RBC723
14RBC-516 RBC727
14RBC-12 RBC757
14RBC-38 RBC797
14RBC-6 RBC857
14RBC-8 RBC867
14RBC-10 RBC877
RBD14-182 RBD1823
14RBD-182 RBD1827
RBD14-183 RBD1833
14RBD-183 RBD1837
14RBD-18277 RBD18277
14RBD-18377 RBD18377
RC55 RC6
10RC-55PT RC55PT
RC10-55PT RC155PT
RC10-250F RC250
10RC-250F RC257
RC10-6 RC333
10RC-6 RC337
10RC-6X RC337-250
RC10-10 RC363
RC10-10X RC364
10RC-10 RC367
10RC-10X RC367-250
RC10-516 RC703
10RC-516 RC707
T&B T&B
DISTRIBUTOR BULK
PACKAGE PACKAGE
RC10-14 RC713
RC10-14X RC714
10RC-14 RC717
10RC-14X RC717-250
RC10-38 RC733
RC10-38X RC734
10RC-38 RC737
10RC-38X RC737-250
RC10-12 RC753
10RC-8 RC777
10RC-8X RC777-250
RC10-8 RC863
RC10-8X RC864
RC10-6F RC1113
RC10-8F RC1123
10RC-8F RC1147
RC10-10F RC1153
10RC-10F RC1157
10RC-10FX RC1157-250
RC10-14F RC1163
RC10-8FS RC1223
RC10-10FS RC1253
10RC-6F RC1337
RC10-6FL RC2203
10RC-6FL RC2207
10RC-6FLX RC2207-250
RC10-8FL RC2213
10RC-8FL RC2217
10RC-8FLX RC2217-250
RC10-10FL RC2223
10RC-10FL RC2227
10RC-10FLX RC2227-250
RC10-14FL RC2233
10RC-14FL RC2237
10RC-250T RC2517
10RC-2577 RC2573
RC10-250A RC2577F
10RC-251T RC25177
2RC10 RCC21
2RCC RCC23
2C12 RCC26
2RC10X RCC217-250
RD8-10 RD367
RD8-14 RD717
RD8-516 RD727
RD8-38 RD737
RD8-12 RD757
2RD8 RDD27
RE6-10 RE267
RE6-14 RE717
RE6-516 RE727
RE6-38 RE737
RE6-12 RE757
2RE6 REE28
RF4-10 RF267
RF4-14 RF717
RF4-516 RF727
RF4-38 RF737
2RF4 RFF29
RG2-10 RG267
RG2-14 RG717
RG2-516 RG727
RG2-38 RG737
RG2-12 RG757
RP12 RP7
United States
Tel: 901.252.8000
Fax: 901.252.1354
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289