Series AM1SS-(J)NZ
1 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 051e R11.D 1 of 3 North America only
FEATURES:
Models
Single output
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Isolation
(VDC)
Max.
Capacitive
Load (µF)
Efficiency
(%)
2.97-3.63
3.3
303
1500
220
72
2.97-3.63
5
200
1500
220
76
2.97-3.63
12
84
1500
220
80
4.5-5.5
3.3
303
1500
220
72
4.5-5.5
5
200
1500
220
80
4.5-5.5
5
200
1500
2400
82
4.5-5.5
9
111
1500
220
80
4.5-5.5
12
84
1500
220
81
4.5-5.5
15
67
1500
220
81
4.5-5.5
24
42
1500
220
81
10.8-13.2
3.3
303
1500
220
72
10.8-13.2
5
200
1500
220
80
10.8-13.2
9
110
1500
220
80
10.8-13.2
12
83
1500
220
81
10.8-13.2
15
67
1500
220
80
10.8-13.2
24
42
1500
220
80
13.5-16.5
15
67
1500
220
81
21.6-26.4
3.3
303
1500
220
72
21.6-26.4
5
200
1500
220
80
21.6-26.4
9
110
1500
220
80
21.6-26.4
12
83
1500
220
81
21.6-26.4
15
67
1500
220
82
21.6-26.4
24
42
1500
220
82
With Momentary short circuit protection of 1 second
Input Specifications
Parameters
Nominal
Typical
Maximum
Units
Voltage range
3.3
2.97-3.63
VDC
5
4.5-5.5
12
10.8-13.2
15
13.5-16.5
24
21.6-26.4
Absolute Max Rating (1 sec. max.)
3.3
5
12
15
24
5
9
18
21
30
VDC
Filter
Capacitor
Isolation Specifications
Parameters
Conditions
Typical
Rated
Units
Tested I/O voltage
60 sec
1500
VDC
Resistance
> 1000
MOhm
Capacitance
20
pF
Unregulated
Operating temperature -40oC to +105oC
4 Pin SIP Package
Input / Output isolation 1500 VDC
Low ripple and noise
Pin compatible with multiple manufacturers
High efficiency up to 82%
Continuous Short Circuit Protection
Click on Series name for product info on aimtec.com
Series AM1SS-(J)NZ
1 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 051e R11.D 2 of 3 North America only
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
See tolerance graph
±5
%
Short Circuit protection
Continuous, unless marked with
Line voltage regulation
For 1.0% Vin, 3.3V Model
For 1.0% Vin, Other Model
±1.5
±1.2
% of Vin
Load voltage regulation
Load 10 100%
12
%
Temperature coefficient
±0.03
%/oC
Ripple & Noise
At 20 MHz Bandwidth
60
m Vp-p
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
100% load
100-300
KHz
Operating temperature
Derating Above 85oC
-40 to +105
oC
Storage temperature
-55 to +125
oC
Maximum case temperature
125
oC
Cooling
Free air convection
Humidity
Non condensing
95
%
Soldering Lead Temperature
1.5mm from Lead, for 10 Sec
300
oC
Case material
Plastic UL94-VO
Weight
Weight for JZ parts
1.2
1.3
g
Dimensions (L x H x W)
0.46 x 0.40x 0.24 inches 11.60 x 10.10 x 6.00 mm
MTBF
>3500K hrs(MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Safety Specifications
Parameters
Agency approvals
cULus (without 15V input and without 3.3V output models) (Also excluding parts with suffix JZ)
Standards
UL 60950-1
Pin Out Specifications Dimensions
Pin
Single
1
- V Input
2
+V Input
3
-V Output
4
+V Output
AM1SS-XXXXS-NZ
AM1SS-XXXXSJZ
XXXX
11.60
(0.46)
10.10
(0.39)
0.50
(0.02)
4.10
(0.161)
6.00
(0.24)
7.62
(0.30)
2.45
(0.10)
0.30
(0.02)
0.50
(0.02)
0.90
(0.04)
Printed
Front
Series AM1SS-(J)NZ
1 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 051e R11.D 3 of 3 North America only
Derating Typical Characteristics
- 40 - 20 0 20 40 60 80 100
100
80
60
40
20
0
Safe Operating Area
Output Power (%)
85
Ambient Temperature º C
Free Air Convection
85º
C
105
Recommended Circuit for EMI Class B
Vin+
Vin-
4.7 µF
50V
Vin+
Vin-
Vo+
Vo-
Load
Aimtec DC/DC
Converter
6.8µH
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
10
%
100
%
50
%
70 %
Rated
Output
Voltage
Output Voltage
Accuracy%
Output Current % (Nominal Input)
+2.5 %
-2.5 %
-7.5 %
5 %
10 %
Typical load line