Inductive Proximity Sensor E2Q2
Limit Switch Style Proximity Sensor
with 5-Position Sensing Head
HSensing face easily adjusts to one of
five directions
HEasy to install and same mounting
dimensions as a standard limit switch
HIntegrated short circuit and reverse
polarity protection
HPlastic body with stainless steel screws
HWeld field immune models available
HConduit openings 1/2”--NPT and Brad
Harrison MiniChangeconnector
versions available
Orderin
g
Information
JDC INPUT TYPE
Type Sensing distance Output type Part number
T
y
p
e
S
e
n
s
i
n
g
d
i
s
t
a
n
c
e
O
u
t
p
u
t
t
y
p
e
1/2”--NPT conduit opening 4--pin MiniChange connector*
Shielded 20 mm (0.79 in) NPN (NO+NC) E2Q2--N20E3--U E2Q2--N20E3--50
S
h
i
e
l
d
e
d
2
0
m
m
(
0
.
7
9
i
n
)
PNP (NO+NC) E2Q2--N20F3--U E2Q2--N20F3--50
Unshielded 30 mm (1.18 in) NPN (NO+NC) E2Q2--N30ME3--U E2Q2--N30ME3--50
U
n
s
h
i
e
l
d
e
d
3
0
m
m
(
1
.
1
8
i
n
)
PNP (NO+NC) E 2 Q 2 -- N 3 0 M F 3 -- U E2Q2--N30MF3--50
Note: *Use Brad Harrison connector #104000A01F120 (12 foot) or equivalent.
JAC INPUT TYPE
Type Sensing distance Output type Part number
T
y
p
e
S
e
n
s
i
n
g
d
i
s
t
a
n
c
e
O
u
t
p
u
t
t
y
p
e
1/2”--NPT conduit opening 4--pin MiniChange connector*
Shielded 15 mm (0.59 in) SCR (NO or NC) E2Q2--N15Y4--U E2Q2--N15Y4--50
Unshielded 30 mm (1.18 in) SCR (NO or NC) E2Q2--N30MY4--U E2Q2--N30MY4--50
Note: *Use Brad Harrison connector #103000A01F120 (12 foot) or equivalent.
JWELD FIELD IMMUNE TYPES
These sensors withstand 25,400 amps at 1 inch (100 mT).
Type Sensing distance Input Output type Part number
T
y
p
e
S
e
n
s
i
n
g
d
i
s
t
a
n
c
e
I
n
p
u
t
type
O
u
t
p
u
t
t
y
p
e
1/2”-NPT conduit opening MiniChange connector
Shielded 15 mm (0.59 in) DC PNP (NO) E2Q2--N15F1--51 E2Q2--N15F1--52*
S
h
i
e
l
d
e
d
1
5
m
m
(
0
.
5
9
i
n
)
AC SCR (NO or NC) E2Q2--N15Y4--51 E2Q2--N15Y4--52**
Note: *Use 4--pin Brad Harrison connector #104000A01F120 (12 foot) or equivalent.
**Use 3--pin Brad Harrison connector #103000A01F120 (12 foot) or equivalent.
E2Q2 E2Q2
3
Specifications
JDC INPUT TYPES
Part number E2Q2--N15jE2Q2--N20jE2Q2--N30j
Operating voltage 10 to 60 VDC; 10 to 30 VDC for weld--field immune types
Current consumption 20 mA max. 10 mA max.
Sensing object Ferrous metals
Sensing distance 15 mm ±10%, shielded 20 mm ±10%, shielded 30 mm ±10%, unshielded
Setting distance with standard
sensing object (L x W x H mm)
0to12mm;0to15mm
(45 x 45 x 1 mm, mild steel)
0to16mm,0to20mm
(60 x 60 x 1 mm, mild steel)
0to24mm,0to30mm
(90 x 90 x 1 mm, mild steel)
Differential travel 15% max. of sensing distance
Control
output
Type F1: PNP--NO E3: NPN (NO+NC)
F3: PNP (NO+NC)
ME3: NPN (NO+NC)
MF3: PNP (NO+NC)
p
Max. load 200 mA
Max. on-- state
voltage drop
3 VDC at 200 mA load current
Response frequency 10 Hz (weld field immune) 150 Hz 100 Hz
Circuit protection Reverse polarity, output short--circuit
Weld field immunity 25,400 amps at 1 inch
(100 mT)
_ _
Indicator Operating indicator (yellow LED)
Material Case PBT
M
a
t
e
r
i
a
l
Terminal base Aluminum
Sensing face PBT
Connections --U, --51: 1/2”--NPT conduit opening; --G: PG 13.5 conduit opening
--50, --52: 4--pin MiniChange connector
Enclosure rating IP67 (EN 60947--1)
Approvals UL listed, CSA certified
Operating ambient temperature -- 2 5 _to 70_C(--13_to 158_F)
Relative humidity 35% to 95% RH
Influence of temperature ±10% max. of sensing distance at 23_C (73.4_F) in temperature range of
-- 2 5 _to 70_C(--13_to 158_F)
Dielectric strength 1,500 VAC, 50/60 Hz for 1 minute between current carrying parts and case
Electromagnetic compatibility EN 60947--5--2
Vibration resistance 10 to 55 Hz, 1 mm amplitude according to IEC 60068--2--6
Shock resistance Approx. 30 G for 11 ms according to IEC 60068--2--27
E2Q2
E2Q2
4
JAC INPUT TYPES
Part number E2Q2-- N15YjE2Q2--N30MY4j
Operating voltage 20 to 253 VAC, 50/60 Hz
Current consumption 20 mA max. 10 mA max.
Leakage current 1.9 mA max. (2.5 mA max. for weld field immune types)
Sensing object Ferrous metals
Sensing distance 15 mm ±10%, shielded 30 mm ±10%, unshielded
Setting distance with standard
sensing object (L x W x H mm)
0to12mm;0to15mm
(45 x 45 x 1 mm, mild steel)
0to24mm,0to30mm
(90 x 90 x 1 mm, mild steel)
Differential travel 15% max. of sensing distance
Control Type SCR (NO or NC)
C
o
n
t
r
o
l
output Max. load 500 mA
Min. load 8 mA (10 mA for weld field immune types)
Max. on-- state
voltage drop
12 VDC at 500 mA load current
Response frequency 20 Hz
Circuit protection None
Weld field immunity 25,400 amps at 1 inch (100 mT)
Indicator Operating indicator (yellow LED)
Material Case PBT
M
a
t
e
r
i
a
l
Terminal base Aluminum
Sensing face PBT
Connections --U, --51: 1/2”--NPT conduit opening;
--50, --52: 3--pin MiniChange connector
Enclosure rating IP67 (EN 60947--1)
Approvals UL listed, CSA certified
Operating ambient temperature -- 2 5 _to 70_C(--13_to 158_F)
Relative humidity 35% to 95% RH
Influence of temperature ±10% max. of sensing distance at 23_C (73.4_F) in temperature range of
-- 2 5 _to 70_C(--13_to 158_F)
Dielectric strength 1,500 VAC, 50/60 Hz for 1 minute between current carrying parts and case
Electromagnetic compatibility EN 60947--5--2
Vibration resistance 10 to 55 Hz, 1 mm amplitude according to IEC 60068--2--6
Shock resistance Approx. 30 G for 11 ms according to IEC 60068--2--27
E2Q2 E2Q2
5
p
eration
JOUTPUT CIRCUIT DIAGRAMS AND TIMING CHARTS
NPN (NO + NC) Output
Main
circuit
Load
+V
-- V
2White
NC output
1Brown
4Black
NO output
3Blue
Target Present
Absent
Load Operates
(output) Releases
Operation ON
indicator OFF
E2Q2--NjjjE3--j
Output NO NC
Load
4.7 kW4.7 kW
Present
Absent
Operates
Releases
ON
OFF
PNP--NO Output (Weld Field Immune Models)
Main
circuit
Load
+V
-- V
Output
1Brown
4Black
3Blue
Target Present
Absent
Load Operates
(output) Releases
Operation ON
indicator OFF
E2Q2--N15F1--5j
Output NO
4.7 kW
E2Q2
E2Q2
6
PNP (NO + NC) Output
Target Present
Absent
Load Operates
(output) Releases
Operation ON
indicator OFF
E2Q2--NjjjF3--j
Output NO NC
Present
Absent
Operates
Releases
ON
OFF
Main
circuit
Load
+V
-- V
2White
NC output
1Brown
4Black
NO
output
3Blue
Load
4.7 kW4.7 kW
AC (NO or NC) Output
Target Present
Absent
Load Operates
(output) Releases
Operation ON
indicator OFF
E2Q2--NjjjY4--j
Output NO NC
Present
Absent
Operates
Releases
ON
OFF
Main
circuit
L1
L1
2
4
3
N
N
NC output
NO output
ONLY ONE OUTPUT ALLOWED!
1
E2Q2 E2Q2
7
Dimensions
Unit: mm (inch)
JE2Q2--Njjjj-- U A N D -- 5 1 T Y P E
11 (0.43)
118 (4.65)
58 (2.28)
40.5 (1.59)
1/2”-- NPT 30
(1.18)
5.5 (0.22)
60 (2.36)
46.5 (1.83)
40
(1.57)
LED(s)
40
(1.57)
JE2Q2--Njjjj-- 5 0 A N D -- 5 2 T Y P E
11 (0.43)
118 (4.65)
58 (2.28)
40.5 (1.59)
133 (5.24)
MiniChange
connector
30
(1.18)
5.5 (0.22)
60 (2.36)46.5 (1.83)
40
(1.57)
LED(s)
40
(1.57)
E2Q2
E2Q2
8
Installation
JPIN ARRANGEMENT
MiniChange connections
E2Q2 E2Q2
Precautions
!CAUTION
Power supply
Do not impose an excessive voltage on the E2Q2, otherwise it
may explode or burn.
Do not impose AC voltage on any E2Q2 DC model, otherwise it
may explode or burn.
Brown
Sensor
Blue
Black Incorrect
Load
Do not connect the AC types without load to the power supply.
The sensor will be damaged.
Sensor
JINSTALLATION
Power Reset Time
The Proximity Sensor is ready to operate within 300 ms after
power is supplied. If power supplies are connected to the
Proximity Sensor and load respectively, be sure to supply power
to the Proximity Sensor before supplying power to the load.
Power OFF
The Proximity Sensor may output a pulse signal when it is turned
off. Therefore, it is recommended to turn off the load before
turning off the Proximity Sensor.
Power Supply Transformer
When using a DC power supply, make sure that the DC power
supply has an insulated transformer. Do not use a DC power
supply with an auto-- transformer.
Sensing Object
Metal coating: The sensing distance of the proximity sensor will
vary with the metal coating on sensing objects.
JWIRING
High--Tension Lines
Wiring through Metal Conduit
If there is a power or high--tension line near the cable of the
Proximity Sensor, wire the cable through an independent metal
conduit to prevent against Proximity Sensor damage or
malfunctioning.
JMOUNTING
The Proximity Sensor must not be subjected to excessive shock
with a hammer when it is installed, otherwise the Proximity
Sensor may be damaged or lose its water resistance.
JENVIRONMENT
Water Resistance
Do not use the proximity sensor underwater, outdoors or in the
rain.
Operating Environment
Be sure to use the Proximity Sensor with operating ambient
temperature range and do not use the Proximity Sensor outdoors
so that its reliability and life expectancy can be maintained.
Although the Proximity Sensor is water resistant, a cover to
protect he proximity sensor from water or soluble machining oil is
recommended so that its reliability and life expectancy can be
maintained. Do not use the Proximity Sensor in an environment
with chemical gas (e.g., strong alkaline or acid gases including
nitric, chromic, and concentrated sulfuric acid gases).
Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in U.S.A.
OMRONELECTRONICSLLC
One EastCommerceDrive
Schaumburg, IL 60173
NOTE:DIMENSIONS SHOWN AREINMILLIMETERS.To convertmillimeterstoinches divideby 25.4.
1-800-55-OMRON
OMRON CANADA, INC.
885 MilnerAvenue
Scarborough,OntarioM1B5V8
416-286-6465
R
OMRONON--LINE
Global-- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci