1 Power Protection and Conditioning MCR Hardwired Series - Power Line Conditioning with Voltage Regulation The MCR Hardwired Series provides excellent noise filtering and surge protection to safeguard connected equipment from damage, degradation or misoperation. Combined with the excellent voltage regulation inherent to SolaHD's ferroresonant design, the MCR can increase the actual Mean Time Between Failure (MTBF) of protected equipment. The MCR is a perfect choice where dirty power, caused by impulses, swell, sags, brownouts and waveform distortion can lead to costly downtime because of damaged equipment. Features * 3% output voltage regulation * Noise attenuation - 120 dB common mode - 60 dB transverse mode * Surge protection tested to ANSI/IEEE C62.41 Class A & B Waveform: - <10 V let through typical * Acts as a step-up or step-down transformer * Harmonic filtering * Hardwired * Galvanic isolation provides exceptional circuit protection. * 25 year typical MTBF * No maintenance required Applications * Industrial automation and control equipment PLCs * Machine tools * Computer loads and electronic equipment * Robotics * Semiconductor fabrication equipment Related Products * On-line UPS (S4K Industrial) * Surge Protection * Three Phase Power Conditioners * Active Tracking(R) Filters Selection Tables: Single Phase Group 2 - MCR Series, 60 Hz Only VA 120 Catalog Number 63-23-112-4 Voltage Input Voltage Output Height (inch) Width (inch) Depth (inch) Ship Weight (lbs) Design Style Elec Conn 120, 208, 240, 480 120 9 4 5 15 1 D 250 63-23-125-4 120, 208, 240, 480 120 10 6 8 27 1 D 500 63-23-150-8 120, 208, 240, 480 120, 208, 240 13 9 7 37 1 E 750 63-23-175-8 120, 208, 240, 480 120, 208, 240 14 9 7 52 1 E 1000* 63-23-210-8 120, 208, 240, 480 120, 208, 240 17 9 7 62 1 E 1500* 63-23-215-8 120, 208, 240, 480 120, 208, 240 17 13 9 95 1 E 2000* 63-23-220-8 120, 208, 240, 480 120, 208, 240 18 13 9 109 1 E 3000* 63-23-230-8 120, 208, 240, 480 120, 208, 240 19 13 9 142 1 E 5000* 63-23-250-8 120, 208, 240, 480 120, 208, 240 28 13 9 222 1 E 7500** 63-28-275-8 208, 240, 480 120, 208, 240 27 26 9 362 2 F 10000** 63-28-310-8 208, 240, 480 120, 208, 240 28 26 9 446 2 F 15000** 63-28-315-8 208, 240, 480 120, 208, 240 28 38 10 710 3 F * Canadian option: cULus certified units must be ordered by changing "-8" (UL only) to "-C8". ** UL Listed Only. Use Group 3 for CSA only models. 36 Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 1 Power Protection and Conditioning Selection Tables: Single Phase Group 3 - MCR Series, 60 Hz Only VA Catalog Number Voltage Input Voltage Output Height (inch) Width (inch) Depth (inch) Ship weight (lbs) Design Style Elec Conn 500 63-31-150-8 600 120, 208, 240 13 9 7 38 1 B 1000 63-32-210-8 600 120, 208, 240 17 9 7 62 1 B 2000 63-32-220-8 600 120, 208, 240 18 13 10 109 1 B 3000 63-32-230-8 600 120, 208, 240 19 13 10 142 1 B 5000 63-29-250-8 * 208, 240, 480, 600 120, 208, 240 28 13 10 221 1 A 7500 63-29-275-8 * 208, 240, 480, 600 120, 208, 240 27 25 10 360 2 A 10000 63-29-310-8 * 208, 240, 480, 600 120, 208, 240 28 25 10 441 2 A 15000 63-29-315-8 * * CSA only models. 208, 240, 480, 600 120, 208, 240 28 38 10 706 3 A Ship weight (lbs) Design Style Group 4 - MCR Series, 50 Hz Only (5% output voltage regulation) VA Catalog Number Voltage Input Voltage Output Height (inch) Width (inch) Depth (inch) Elec Conn 120 63-23-612-8 110, 120, 220, 240, 380, 415 110, 120, 220, 240 9 6 8 24 1 C 250 63-23-625-8 110, 120, 220, 240, 380, 415 110, 120, 220, 240 11 6 8 27 1 C 500 63-23-650-8 110, 120, 220, 240, 380, 415 110, 120, 220, 240 13 9 7 40 1 C 1000 63-23-710-8 110, 120, 220, 240, 380, 415 110, 120, 220, 240 18 9 7 64 1 C 2000 63-23-720-8 110, 120, 220, 240, 380, 415 110, 120, 220, 240 18 13 10 113 1 C 3000 63-23-730-8 110, 120, 220, 240, 380, 415 110, 120, 220, 240 27 13 10 162 1 C 5000 63-23-750-8 110, 120, 220, 240, 380, 415 110, 120, 220, 240 30 13 10 266 1 C 7500 63-28-775-8 220, 240, 380, 415 110, 120, 220, 240 28 26 10 393 2 C1 10000 63-28-810-8 220, 240, 380, 415 110, 120, 220, 240 30 26 10 490 2 C2 15000 63-28-815-8 220, 240, 380, 415 110, 120, 220, 240 30 38 10 776 3 C2 Specifications Parameter Condition Value Input Voltage Current 1 Frequency Continuous at full load (lower input voltage possible at lighter load) +10% to -20% of nominal For temporary surge or sags +20% to -35% of nominal at Full Load & 80% of nominal input voltage Iin (VA/.89)/(Vin x 80%) See Operating Characteristics section for details. 50 Hz or 60 Hz depending on model Output Line Regulation Overload Protection Output Harmonic Distortion Noise Attenuation Vin >80% and <110% of nominal 5% for 50 Hz units, 3% for 60 Hz units At Nominal Input Voltage Current limited at 1.65 times rated current At full load within input range 3% total RMS content Common Mode Transverse Mode 120 dB 60 dB General At Full Load Up to 92% Storage Temperature Humidity <95% non-condensing -20 to +85C Operating Temperature Humidity <95% non-condensing -20 to 50C Full Resistive Noise 35 dBA to 65 dBA 60 Hz Models UL1012, CSA evaluated by UL 50 Hz Models CE (EMC & LVD) See General Information section for details 10 + 2 Years Efficiency Audible Noise Approvals Warranty Notes: 1 - Consult user manual for fuse sizing. 2 - It is recommended that the unit run at a minimum of 40-50% load. Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 37 1 Power Protection and Conditioning Electrical Connections B A Primary Voltage Interconnect Connect Lines To 208 H1 to H4 H2 to H5 H1 & H5 240 H1 to H4 H3 to H6 H1 & H6 480 H3 to H4 H1 & H6 600 H3 to H4 H1 & H7 Secondary Voltage Interconnect Connect Lines To Secondary Voltage 120 X1 & X2 or X3 & X2 208 240 Primary Voltage Interconnect 600 H1 & H2 Interconnect 110-120 H1 & H4 220-240 H2 to H3 H1 & H4 380-415 H2 to H3 H1 & H5 Secondary Voltage Interconnect Connect Lines To 110 X1 & X2 or X3 & X2 120 X4 & X2 or X5 & X2 X4 & X5 208 X4 & X5 220 X1 & X3 X1 & X3 240 X1 & X3 240 X4 & X5 MCR 60 Hz 500-3000 VA 220-240 H1 to H3 H2 to H5 H1 & H5 380-415 H2 to H3 H1 & H4 Secondary Voltage Interconnect Connect Lines To 38 Connect Lines To H1 to H3 H2 to H4 X1 & X2 or X3 & X2 Connect Lines To 110 X1 & X2 or X2 & X3 120 X4 & X2 or X5 & X2 220 X1 & X3 240 X4 & X5 MCR 50 Hz 7500 VA Interconnect 120 MCR 50 Hz 120-5000 VA C2 C1 Interconnect Primary Voltage Connect Lines To MCR 60 Hz 5000-15000 VA Primary Voltage Connect Lines To C D Primary Voltage Interconnect Connect Lines To Primary Voltage 220-240 H2 to H3 H1 & H4 120 H1 & H2 Interconnect Connect Lines To 380-415 H2 to H3 H1 & H5 208 H1 & H3 Secondary Voltage Interconnect Connect Lines To 240 H1 & H4 110 X1 & X2 or X3 & X2 480 120 X4 & X2 or X5 & X2 Secondary Voltage 220 X1 & X3 120 240 X4 & X5 MCR 50 Hz 10000-15000 VA Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. H1 & H5 Interconnect Connect Lines To X1 & X2 MCR 60 Hz 120-250 VA 1 Power Protection and Conditioning Electrical Connections E Primary Voltage Interconnect G F Connect Lines To H1 & H2 Primary Voltage 208 H1 & H3 208 H2 & H3 240 H1 & H4 240 H2 & H4 480 H1 & H5 480 H1 & H4 Connect Lines To Secondary Voltage 120 X1 & X2 or X3 & X2 120 X1 & X2 or X3 & X2 208 X4 & X5 208 240 X1 & X3 240 120 Secondary Voltage Interconnect Interconnect Connect Lines To Interconnect Primary Voltage Interconnect Connect Lines To 120 H1 to H3 to H5 to H7 H2 to H4 to H6 to H8 H1 & H2 240 H2 to H3 H6 to H7 H1 to H5 H4 to H8 H1 & H4 480 H2 to H3 H4 to H5 H6 to H7 H1 & H8 X4 & X5 Secondary Voltage Interconnect Connect Lines To X1 & X3 120 Connect Lines To X1 & X2 CVS 60 Hz 250 VA only MCR 60 Hz 7500, 10000 and 15000 VA MCR 60 Hz 500-5000 VA H Series-Multiple Primary with Tap for two input voltages J Open MCR/CVS terminal Primary Voltage Interconnect Connect Lines To 120 H1 to H3 to H6 to H8 H2 to H5 to H7 to H10 H1 & H2 30 & 60 VA Primary Voltage 120 VA Primary Voltage 7500 VA Primary Voltage Interconnect Connect Lines To 120 N/A N/A Note: H3 & H4 are not used H1 & H2 N/A 120 240 H1 to H3 H2 to H4 H1 & H4 208 H2 to H3 H1 to H6 H7 to H8 H4 to H9 H1 & H4 240 H2 to H3 H7 to H8 H1 to H6 H5 to H10 H1 & H5 N/A 240 480 H2 to H3 H1 & H4 120 VA Secondary Voltage 7500 VA Secondary Voltage Interconnect Connect Lines To 120 N/A X1 & X2 480 H2 to H3 H5 to H6 H7 to H8 H1 & H10 30 & 60 VA Secondary Voltage Secondary Voltage Interconnect Connect Lines To 120 120 X1 & X2 or X3 & X2 N/A N/A 120 X1 & X2 or X3 & X2 240 X1 & X3 N/A N/A 240 X1 & X3 CVS 60 Hz 500-5000 VA Note: Secondaries are not grounded. Ground X2 per Code. CVS 60 Hz 30-120 VA & 7500 VA Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 39