MODEL LCA100S-3 LCA100S-5
LCA100S-12 LCA100S-15 LCA100S-24
LCA100S-24-H
LCA100S-36 LCA100S-48
MAX OUTPUT WATTAGE[W] 60 100 102 105 103.2 103.2 108 105.6
DC OUTPUT 3V 20A 5V 20A 12V 8.5A 15V 7A 24V 4.3A 24V 4.3A 36V 3A 48V 2.2A
SPECIFICATIONS
MODEL LCA100S-3 LCA100S-5
LCA100S-12 LCA100S-15 LCA100S-24
LCA100S-24-H
LCA100S-36 LCA100S-48
INPUT
VOLTAGE[V] AC85 - 132 1for DC110 - 170
CURRENT[A]
ACIN 100V
2.5typ (Io=100%)
FREQUENCY[Hz] 47 - 440 or DC
EFFICIENCY[%] 74typ 79typ 83typ 84typ 85typ 85typ 85typ 85typ
INRUSH CURRENT[A]
ACIN 100V
15typ (Io=100%)
LEAKAGE CURRENT[mA] 0.5max (60Hz,According to UL,CSA and DEN-AN)
OUTPUT
VOLTAGE[V] 3 5 121524243648
CURRENT[A]
*3
20 20 8.5 7 4.3 4.3 (Peak 7)3 2.2
LINE REGULATION[mV] 20max 20max 48max 60max 96max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 100max 120max 150max 150max 240max 300max
RIPPLE[mVp-p]
0to+50
C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-10-0
C
*1
140max 140max 160max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]
0to+50
C
*1
120max 120max 150max 150max 150max 250max 250max 350max
-10-0
C
*1
160max 160max 180max 180max 180max 280max 300max 400max
TEMPERATURE REGULATION[mV]
0to+50
C
50max 50max 120max 150max 240max 240max 360max 480max
-10 to +50C
60max 60max 150max 180max 290max 290max 450max 600max
DRIFT[mV]
*2
20max 20max 48max 60max 96max 96max 144max 192max
START-UP TIME[ms] 200max (ACIN 85V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)20typ (ACIN 100V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.6 4.5 - 5.5
Fixed ("Y"which can be adjusted the output is available as optional: 12,15,24,36,48V t10%)
OUTPUT VOLTAGE SETTING[V]
xx xx 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 23.0 - 25.0 34.5 - 37.5 46.0 - 50.0
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating (works over 105% of peak current at option -H)and recovers automatically
OVERVOLTAGE PROTECTION
4.00 - 5.25V Works at 115 - 140% of rating
OPERATING INDICATION Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +60C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,CSA C22.2 No.60950-1 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B,VCCI-B
OTHERS CASE SIZE/WEIGHT 62X32X222mm (WXHXD)/ 370g max (without chassis and cover)
COOLING METHOD Convection