MODEL LCA10S-5 LCA10S-5-H LCA10S-12 LCA10S-15 LCA10S-24
MAX OUTPUT WATTAGE[W] 10 10 10.8 10.5 12
DC OUTPUT 5V 2A 5V 2A 12V 0.9A 15V 0.7A 24V 0.5A
SPECIFICATIONS
MODEL LCA10S-5 LCA10S-5-H LCA10S-12 LCA10S-15 LCA10S-24
INPUT
VOLTAGE[V] AC85 - 132 1for DC110 - 170
CURRENT[A]
ACIN 100V
0.3typ (Io=100%)
FREQUENCY[Hz] 47 - 440 or DC
EFFICIENCY[%] 71typ 71typ 75typ 75typ 78typ
INRUSH CURRENT[A]
ACIN 100V
25typ (Io=100%)
LEAKAGE CURRENT[mA]
0.5max (60Hz,According to UL,CSA and DEN-AN)
OUTPUT
VOLTAGE[V] 55121524
CURRENT[A] 22
(Peak 3)0.9 0.7 0.5
LINE REGULATION[mV] 20max 20max 48max 60max 96max
LOAD REGULATION[mV] 40max 40max 100max 120max 150max
RIPPLE[mVp-p]
0to+50
C
*1
80max 80max 120max 120max 120max
-10-0
C
*1
140max 140max 160max 160max 160max
RIPPLE NOISE[mVp-p]
0to+50
C
*1
120max 120max 150max 150max 150max
-10-0
C
*1
160max 160max 180max 180max 180max
TEMPERATURE REGULATION[mV]
50max 50max 120max 150max 240max
DRIFT[mV]
*2
20max 20max 48max 60max 96max
START-UP TIME[ms] 100max (ACIN 85V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)20typ (ACIN 100V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
Fixed ("Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12,15,24V t10%)
OUTPUT VOLTAGE SETTING[V]
4.9 - 5.3 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating (works over 105% of peak current at option -H)and recovers automatically
OVERVOLTAGE PROTECTION
Works over 115% of rating,by zener diode clamping
OPERATING INDICATION
Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +60C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,CSA C22.2 No.60950-1 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B,VCCI-B
OTHERS CASE SIZE/WEIGHT 49X17X94mm (WXHXD)/ 65g max
COOLING METHOD Convection
*1Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25Cwith the input voltage held constant at the rated input/output.
*3Please contact us about safety approvals for the model with option.
*Avoid prolonged use under over-load.
LCA10S
AC-DC Power Supplies Open Frame/Enclosed type
LC A 10 S -5 -O
Ordering information
1Series name
2100/120V input
3Output wattage
4Single output
5Output voltage
6Optional *3
C :with Coating
G :Low leakage current
Y :with Potentiometer
R
123456
LCA
LCA-2
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
¡DERATING CURVE
¡RISE TIME & FALL TIME (LCA10S-5)
¡OVERCURRENT CHARACTERISTICS (LCA10S-5)
¡STATIC CHARACTERISTICS (LCA10S-5)
LCA
LCA-3
LCA10S
External view
Performance data
MODEL LCA15S-5 LCA15S-12 LCA15S-15 LCA15S-24
MAX OUTPUT WATTAGE[W] 15 15.6 15 16.8
DC OUTPUT 5V 3A 12V 1.3A 15V 1A 24V 0.7A
SPECIFICATIONS
MODEL LCA15S-5 LCA15S-12 LCA15S-15 LCA15S-24
INPUT
VOLTAGE[V] AC85 - 132 1for DC110 - 170
CURRENT[A]
ACIN 100V
0.4typ (Io=100%)
FREQUENCY[Hz] 47 - 440 or DC
EFFICIENCY[%] 72typ 75typ 75typ 78typ
INRUSH CURRENT[A]
ACIN 100V
20typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA]
0.5max (60Hz,According to UL,CSA and DEN-AN)
OUTPUT
VOLTAGE[V] 5 121524
CURRENT[A] 3 1.3 1 0.7
LINE REGULATION[mV] 20max 48max 60max 96max
LOAD REGULATION[mV] 40max 100max 120max 150max
RIPPLE[mVp-p]
0to+50
C
*1
80max 120max 120max 120max
-10-0
C
*1
140max 160max 160max 160max
RIPPLE NOISE[mVp-p]
0to+50
C
*1
120max 150max 150max 150max
-10-0
C
*1
160max 180max 180max 180max
TEMPERATURE REGULATION[mV]
50max 120max 150max 240max
DRIFT[mV]
*2
20max 48max 60max 96max
START-UP TIME[ms] 100max (ACIN 85V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)20typ (ACIN 100V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
Fixed ("Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12,15,24V t10%)
OUTPUT VOLTAGE SETTING[V]
4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION
Works over 115% of rating,by zener diode clamping
OPERATING INDICATION
Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +60C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,CSA C22.2 No.60950-1 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B,VCCI-B
OTHERS CASE SIZE/WEIGHT 50X17X115mm (WXHXD)/ 80g max
COOLING METHOD Convection
*1Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25Cwith the input voltage held constant at the rated input/output.
*3Please contact us about safety approvals for the model with option.
*Avoid prolonged use under over-load.
LCA15S
AC-DC Power Supplies Open Frame/Enclosed type
LC A 15 S -5 -O
Ordering information
1Series name
2100/120V input
3Output wattage
4Single output
5Output voltage
6Optional *3
C :with Coating
G :Low leakage current
Y :with Potentiometer
R
123456
LCA
LCA-4
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
¡DERATING CURVE
¡RISE TIME & FALL TIME (LCA15S-5)
¡OVERCURRENT CHARACTERISTICS (LCA15S-5)
¡STATIC CHARACTERISTICS (LCA15S-5)
LCA
LCA-5
LCA15S
External view
Performance data
MODEL LCA30S-3 LCA30S-5 LCA30S-12 LCA30S-15 LCA30S-24 LCA30S-36 LCA30S-48
MAX OUTPUT WATTAGE[W] 18 30 30 30 31.2 32.4 33.6
DC OUTPUT 3V 6A 5V 6A 12V 2.5A 15V 2A 24V 1.3A 36V 0.9A 48V 0.7A
SPECIFICATIONS
MODEL LCA30S-3 LCA30S-5 LCA30S-12 LCA30S-15 LCA30S-24 LCA30S-36 LCA30S-48
INPUT
VOLTAGE[V] AC85 - 132 1for DC110 - 170
CURRENT[A]
ACIN 100V
0.7typ (Io=100%)
FREQUENCY[Hz] 47 - 440 or DC
EFFICIENCY[%] 69typ 75typ 80typ 81typ 82typ 80typ 80typ
INRUSH CURRENT[A]
ACIN 100V
25typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA]
0.5max (60Hz,According to UL,CSA and DEN-AN)
OUTPUT
VOLTAGE[V] 3 5 12 15 24 36 48
CURRENT[A] 6 6 2.5 2 1.3 0.9 0.7
LINE REGULATION[mV] 20max 20max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 100max 120max 150max 240max 300max
RIPPLE[mVp-p]
0to+50
C
*1
80max 80max 120max 120max 120max 150max 150max
-10-0
C
*1
140max 140max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]
0to+50
C
*1
120max 120max 150max 150max 150max 250max 350max
-10-0
C
*1
160max 160max 180max 180max 180max 300max 400max
TEMPERATURE REGULATION[mV]
50max 50max 120max 150max 240max 360max 480max
DRIFT[mV]
*2
20max 20max 48max 60max 96max 144max 192max
START-UP TIME[ms] 100max (ACIN 85V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)20typ (ACIN 100V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.6
Fixed ("Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12,15,24,36,48V t10%)
OUTPUT VOLTAGE SETTING[V]
xx 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 34.5 - 37.5 46.0 - 50.0
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION
4.00V min Works over 115% of rating,by zener diode clamping
OPERATING INDICATION
Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +60C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,CSA C22.2 No.60950-1 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B,VCCI-B
OTHERS CASE SIZE/WEIGHT 50X25X132.5mm (WXHXD)/ 150g max
COOLING METHOD Convection
*1Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25Cwith the input voltage held constant at the rated input/output.
*3Please contact us about safety approvals for the model with option.
*Avoid prolonged use under over-load.
LCA30S
AC-DC Power Supplies Open Frame/Enclosed type
LC A 30 S -5 -O
Ordering information
1Series name
2100/120V input
3Output wattage
4Single output
5Output voltage
6Optional *3
C :with Coating
G :Low leakage current
Y :with Potentiometer
R
123456
LCA
LCA-6
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
¡DERATING CURVE
¡RISE TIME & FALL TIME (LCA30S-5)
¡OVERCURRENT CHARACTERISTICS (LCA30S-5)
¡STATIC CHARACTERISTICS (LCA30S-5)
LCA
LCA-7
LCA30S
External view
Performance data
MODEL LCA50S-3 LCA50S-5 LCA50S-12 LCA50S-15 LCA50S-24
LCA50S-24-H
LCA50S-36 LCA50S-48
MAX OUTPUT WATTAGE[W] 30 50 51.6 52.5 60 60 61.2 62.4
DC OUTPUT 3V 10A 5V 10A 12V 4.3A 15V 3.5A 24V 2.5A 24V 2.5A 36V 1.7A 48V 1.3A
SPECIFICATIONS
MODEL LCA50S-3 LCA50S-5 LCA50S-12 LCA50S-15 LCA50S-24
LCA50S-24-H
LCA50S-36 LCA50S-48
INPUT
VOLTAGE[V] AC85 - 132 1for DC110 - 170
CURRENT[A]
ACIN 100V
1.3typ (Io=100%)
FREQUENCY[Hz] 47 - 440 or DC
EFFICIENCY[%] 71typ 78typ 80typ 81typ 82typ 82typ 82typ 82typ
INRUSH CURRENT[A]
ACIN 100V
30typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA] 0.5max (60Hz,According to UL,CSA and DEN-AN)
OUTPUT
VOLTAGE[V] 3 5 121524243648
CURRENT[A]
*3
10 10 4.3 3.5 2.5 2.5 (Peak 3)1.7 1.3
LINE REGULATION[mV] 20max 20max 48max 60max 96max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 100max 120max 150max 150max 240max 300max
RIPPLE[mVp-p]
0to+50
C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-10-0
C
*1
140max 140max 160max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]
0to+50
C
*1
120max 120max 150max 150max 150max 150max 250max 350max
-10-0
C
*1
160max 160max 180max 180max 180max 180max 300max 400max
TEMPERATURE REGULATION[mV]
0to+50
C
50max 50max 120max 150max 240max 240max 360max 480max
-10 to +50C
60max 60max 150max 180max 290max 290max 450max 600max
DRIFT[mV]
*2
20max 20max 48max 60max 96max 96max 144max 192max
START-UP TIME[ms] 200max (ACIN 85V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)20typ (ACIN 100V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as optional: 5,12,15,24,36,48V t10%)
OUTPUT VOLTAGE SETTING[V]
xx 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 23.0 - 25.0 34.5 - 37.5 46.0 - 50.0
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating (works over 105% of peak current at option -H)and recovers automatically
OVERVOLTAGE PROTECTION
4.00 - 5.25V Works at 115 - 140% of rating
OPERATING INDICATION Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +60C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,CSA C22.2 No.60950-1 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B,VCCI-B
OTHERS CASE SIZE/WEIGHT 50X25X195mm (WXHXD)/ 200g max
COOLING METHOD Convection
*1Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25Cwith the input voltage held constant at the rated input/output.
*3Peak load for 10 sec. or less is acceptable(The average current has to be less than the rated current).
*4Please contact us about safety approvals for the model with option.
LCA50S
AC-DC Power Supplies Open Frame/Enclosed type
LC A 50 S -5 -O
Ordering information
1Series name
2100/120V input
3Output wattage
4Single output
5Output voltage
6Optional *4
C :with Coating
G :Low leakage current
Y :with Potentiometer
R
123456
LCA
LCA-8
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
¡DERATING CURVE
¡RISE TIME & FALL TIME (LCA50S-5)
¡OVERCURRENT CHARACTERISTICS (LCA50S-5)
¡STATIC CHARACTERISTICS (LCA50S-5)
LCA
LCA-9
LCA50S
External view
Performance data
MODEL LCA75S-3 LCA75S-5 LCA75S-12 LCA75S-15 LCA75S-24
LCA75S-24-H
LCA75S-36 LCA75S-48
MAX OUTPUT WATTAGE[W] 45 75 75.6 75 76.8 76.8 75.6 76.8
DC OUTPUT 3V 15A 5V 15A 12V 6.3A 15V 5A 24V 3.2A 24V 3.2A 36V 2.1A 48V 1.6A
SPECIFICATIONS
MODEL LCA75S-3 LCA75S-5 LCA75S-12 LCA75S-15 LCA75S-24
LCA75S-24-H
LCA75S-36 LCA75S-48
INPUT
VOLTAGE[V] AC85 - 132 1for DC110 - 170
CURRENT[A]
ACIN 100V
1.9typ (Io=100%)
FREQUENCY[Hz] 47 - 440 or DC
EFFICIENCY[%] 72typ 79typ 81typ 83typ 84typ 84typ 84typ 84typ
INRUSH CURRENT[A]
ACIN 100V
30typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA] 0.5max (60Hz,According to UL,CSA and DEN-AN)
OUTPUT
VOLTAGE[V] 3 5 121524243648
CURRENT[A]
*3
15 15 6.3 5 3.2
3.2 (Peak 4.2)
2.1 1.6
LINE REGULATION[mV] 20max 20max 48max 60max 96max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 100max 120max 150max 150max 240max 300max
RIPPLE[mVp-p]
0to+50
C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-10-0
C
*1
140max 140max 160max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]
0to+50
C
*1
120max 120max 150max 150max 150max 150max 250max 350max
-10-0
C
*1
160max 160max 180max 180max 180max 180max 300max 400max
TEMPERATURE REGULATION[mV]
0to+50
C
50max 50max 120max 150max 240max 240max 360max 480max
-10 to +50C
60max 60max 150max 180max 290max 290max 450max 600max
DRIFT[mV]
*2
20max 20max 48max 60max 96max 96max 144max 192max
START-UP TIME[ms] 200max (ACIN 85V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)20typ (ACIN 100V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as optional: 5,12,15,24,36,48V t10%)
OUTPUT VOLTAGE SETTING[V]
xx 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 23.0 - 25.0 34.5 - 37.5 46.0 - 50.0
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating (works over 105% of peak current at option -H)and recovers automatically
OVERVOLTAGE PROTECTION
4.00 - 5.25V Works at 115 - 140% of rating
OPERATING INDICATION Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +60C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,CSA C22.2 No.60950-1 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B,VCCI-B
OTHERS CASE SIZE/WEIGHT 50X32X222mm (WXHXD)/ 300g max
COOLING METHOD Convection
*1Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25Cwith the input voltage held constant at the rated input/output.
*3Peak load for 10 sec. or less is acceptable(The average current has to be less than the rated current).
*4Please contact us about safety approvals for the model with option.
LCA75S
AC-DC Power Supplies Open Frame/Enclosed type
LC A 75 S -5 -O
Ordering information
1Series name
2100/120V input
3Output wattage
4Single output
5Output voltage
6Optional *4
C :with Coating
G :Low leakage current
Y :with Potentiometer
R
123456
LCA
LCA-10
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
¡DERATING CURVE
¡RISE TIME & FALL TIME (LCA75S-5)
¡OVERCURRENT CHARACTERISTICS (LCA75S-5)
¡STATIC CHARACTERISTICS (LCA75S-5)
LCA
LCA-11
LCA75S
External view
Performance data
MODEL LCA100S-3 LCA100S-5
LCA100S-12 LCA100S-15 LCA100S-24
LCA100S-24-H
LCA100S-36 LCA100S-48
MAX OUTPUT WATTAGE[W] 60 100 102 105 103.2 103.2 108 105.6
DC OUTPUT 3V 20A 5V 20A 12V 8.5A 15V 7A 24V 4.3A 24V 4.3A 36V 3A 48V 2.2A
SPECIFICATIONS
MODEL LCA100S-3 LCA100S-5
LCA100S-12 LCA100S-15 LCA100S-24
LCA100S-24-H
LCA100S-36 LCA100S-48
INPUT
VOLTAGE[V] AC85 - 132 1for DC110 - 170
CURRENT[A]
ACIN 100V
2.5typ (Io=100%)
FREQUENCY[Hz] 47 - 440 or DC
EFFICIENCY[%] 74typ 79typ 83typ 84typ 85typ 85typ 85typ 85typ
INRUSH CURRENT[A]
ACIN 100V
15typ (Io=100%)
LEAKAGE CURRENT[mA] 0.5max (60Hz,According to UL,CSA and DEN-AN)
OUTPUT
VOLTAGE[V] 3 5 121524243648
CURRENT[A]
*3
20 20 8.5 7 4.3 4.3 (Peak 7)3 2.2
LINE REGULATION[mV] 20max 20max 48max 60max 96max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 100max 120max 150max 150max 240max 300max
RIPPLE[mVp-p]
0to+50
C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-10-0
C
*1
140max 140max 160max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]
0to+50
C
*1
120max 120max 150max 150max 150max 250max 250max 350max
-10-0
C
*1
160max 160max 180max 180max 180max 280max 300max 400max
TEMPERATURE REGULATION[mV]
0to+50
C
50max 50max 120max 150max 240max 240max 360max 480max
-10 to +50C
60max 60max 150max 180max 290max 290max 450max 600max
DRIFT[mV]
*2
20max 20max 48max 60max 96max 96max 144max 192max
START-UP TIME[ms] 200max (ACIN 85V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)20typ (ACIN 100V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.6 4.5 - 5.5
Fixed ("Y"which can be adjusted the output is available as optional: 12,15,24,36,48V t10%)
OUTPUT VOLTAGE SETTING[V]
xx xx 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 23.0 - 25.0 34.5 - 37.5 46.0 - 50.0
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating (works over 105% of peak current at option -H)and recovers automatically
OVERVOLTAGE PROTECTION
4.00 - 5.25V Works at 115 - 140% of rating
OPERATING INDICATION Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +60C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,CSA C22.2 No.60950-1 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B,VCCI-B
OTHERS CASE SIZE/WEIGHT 62X32X222mm (WXHXD)/ 370g max (without chassis and cover)
COOLING METHOD Convection
*1Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25Cwith the input voltage held constant at the rated input/output.
*3Peak load for 20 sec. or less is acceptable(The average current has to be less than the rated current).
*4Please contact us about safety approvals for the model with option.
*Derating is required when operated with chassis and cover.
LCA100S
AC-DC Power Supplies Open Frame/Enclosed type
LC A 100 S -5 -O
Ordering information
1Series name
2100/120V input
3Output wattage
4Single output
5Output voltage
6Optional *4
C :with Coating
G :Low leakage current
S :with Chassis
SN
:with Chassis & cover
Y :with Potentiometer
R
123456
LCA
LCA-12
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
¡DERATING CURVE
¡RISE TIME & FALL TIME (LCA100S-5)
¡OVERCURRENT CHARACTERISTICS (LCA100S-5)
¡STATIC CHARACTERISTICS (LCA100S-5)
LCA
LCA-13
LCA100S
External view
Performance data
MODEL LCA150S-3 LCA150S-5
LCA150S-12 LCA150S-15 LCA150S-24
LCA150S-24-H
LCA150S-36 LCA150S-48
MAX OUTPUT WATTAGE[W] 90 150 150 150 151.2 151.2 151.2 153.6
DC OUTPUT 3V 30A 5V 30A 12V 12.5A 15V 10A 24V 6.3A 24V 6.3A 36V 4.2A 48V 3.2A
SPECIFICATIONS
MODEL LCA150S-3 LCA150S-5
LCA150S-12 LCA150S-15 LCA150S-24
LCA150S-24-H
LCA150S-36 LCA150S-48
INPUT
VOLTAGE[V] AC85 - 132 1for DC110 - 170
CURRENT[A]
ACIN 100V
3.6typ (Io=100%)
FREQUENCY[Hz] 47 - 440 or DC
EFFICIENCY[%] 72typ 79typ 82typ 83typ 85typ 85typ 85typ 85typ
INRUSH CURRENT[A]
ACIN 100V
15typ (Io=100%)
LEAKAGE CURRENT[mA] 0.5max (60Hz,According to UL,CSA and DEN-AN)
OUTPUT
VOLTAGE[V] 3 5 121524243648
CURRENT[A]
*3
30 30 12.5 10 6.3
6.3 (Peak 10)
4.2 3.2
LINE REGULATION[mV] 20max 20max 48max 60max 96max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 100max 120max 150max 150max 240max 300max
RIPPLE[mVp-p]
0to+50
C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-10-0
C
*1
140max 140max 160max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]
0to+50
C
*1
120max 120max 150max 150max 150max 150max 250max 350max
-10-0
C
*1
160max 160max 180max 180max 180max 180max 300max 400max
TEMPERATURE REGULATION[mV]
0to+50
C
50max 50max 120max 150max 240max 240max 360max 480max
-10 to +50C
60max 60max 150max 180max 290max 290max 450max 600max
DRIFT[mV]
*2
20max 20max 48max 60max 96max 96max 144max 192max
START-UP TIME[ms] 200max (ACIN 85V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)20typ (ACIN 100V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.6 4.5 - 5.5
Fixed ("Y"which can be adjusted the output is available as optional: 12,15,24,36,48V t10%)
OUTPUT VOLTAGE SETTING[V]
xx xx 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 23.0 - 25.0 34.5 - 37.5 46.0 - 50.0
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating (works over 105% of peak current at option -H)and recovers automatically
OVERVOLTAGE PROTECTION
4.00 - 5.25V Works at 115 - 140% of rating
OPERATING INDICATION Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +60C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,CSA C22.2 No.60950-1 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B,VCCI-B
OTHERS CASE SIZE/WEIGHT 75X36X222mm (WXHXD)/ 550g max (without chassis and cover)
COOLING METHOD Convection
*1Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25Cwith the input voltage held constant at the rated input/output.
*3Peak load for 15 sec. or less is acceptable(The average current has to be less than the rated current).
*4Please contact us about safety approvals for the model with option.
*Derating is required when operated with chassis and cover.
LCA150S
AC-DC Power Supplies Open Frame/Enclosed type
LC A 150 S -5 -O
Ordering information
1Series name
2100/120V input
3Output wattage
4Single output
5Output voltage
6Optional *4
C :with Coating
G :Low leakage current
S :with Chassis
SN
:with Chassis & cover
Y :with Potentiometer
R
123456
LCA
LCA-14
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
¡DERATING CURVE
¡RISE TIME & FALL TIME (LCA150S-5)
¡OVERCURRENT CHARACTERISTICS (LCA150S-5)
¡STATIC CHARACTERISTICS (LCA150S-5)
LCA
LCA-15
LCA150S
External view
Performance data