Ordering information AC-DC Power Supplies Open Frame/Enclosed type LCA10S LC 1 A 2 10 3 S 4 Recommended EMI/EMC Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series -5 5 -O 6 1Series name 2100/120V input 3Output wattage 4Single output 5Output voltage 6Optional *3 C :with Coating G :Low leakage current Y :with Potentiometer *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT LCA10S-5 10 5V 2A LCA10S-5-H 10 5V 2A LCA10S-12 10.8 12V 0.9A LCA10S-15 10.5 15V 0.7A LCA10S-24 12 24V 0.5A LCA10S-12 LCA10S-15 LCA10S-24 75typ 75typ 78typ DEN-AN) 12 0.9 48max 100max 120max 160max 150max 180max 120max 48max 15 0.7 60max 120max 120max 160max 150max 180max 150max 60max 24 0.5 96max 150max 120max 160max 150max 180max 240max 96max SPECIFICATIONS INPUT LCA OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 * MODEL VOLTAGE[V] ACIN 100V CURRENT[A] FREQUENCY[Hz] EFFICIENCY[%] INRUSH CURRENT[A] ACIN 100V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 TEMPERATURE REGULATION[mV] *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD LCA10S-5 LCA10S-5-H AC85 - 132 1f or DC110 - 170 0.3typ (Io=100%) 47 - 440 or DC 71typ 71typ 25typ (Io=100%) 0.5max (60Hz, According to UL, CSA and 5 5 2 2 (Peak 3) 20max 20max 40max 40max 80max 80max 140max 140max 120max 120max 160max 160max 50max 50max 20max 20max 100max (ACIN 85V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) Fixed ("Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12, 15, 24V t10%) 4.9 - 5.3 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 Works over 105% of rating (works over 105% of peak current at option -H) and recovers automatically Works over 115% of rating, by zener diode clamping Not provided Not provided Not provided AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN Complies with FCC-B, VCCI-B 49X17X94mm (WXHXD) / 65g max Convection Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output. Please contact us about safety approvals for the model with option. Avoid prolonged use under over-load. LCA-2 LCA10S External view LCA Performance data STATIC CHARACTERISTICS (LCA10S-5) RISE TIME & FALL TIME (LCA10S-5) OVERCURRENT CHARACTERISTICS (LCA10S-5) DERATING CURVE LCA-3 Ordering information AC-DC Power Supplies Open Frame/Enclosed type LCA15S LC 1 A 2 15 3 S 4 Recommended EMI/EMC Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series -5 5 -O 6 1Series name 2100/120V input 3Output wattage 4Single output 5Output voltage 6Optional *3 C :with Coating G :Low leakage current Y :with Potentiometer *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT LCA15S-5 15 5V 3A LCA15S-12 15.6 12V 1.3A LCA15S-15 15 15V 1A LCA15S-24 16.8 24V 0.7A SPECIFICATIONS INPUT LCA OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 * MODEL VOLTAGE[V] ACIN 100V CURRENT[A] FREQUENCY[Hz] EFFICIENCY[%] INRUSH CURRENT[A] ACIN 100V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 TEMPERATURE REGULATION[mV] *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD LCA15S-5 LCA15S-12 LCA15S-15 LCA15S-24 AC85 - 132 1f or DC110 - 170 0.4typ (Io=100%) 47 - 440 or DC 72typ 75typ 75typ 78typ 20typ (Io=100%) (At cold start) 0.5max (60Hz, According to UL, CSA and DEN-AN) 5 12 15 24 3 1.3 1 0.7 20max 48max 60max 96max 40max 100max 120max 150max 80max 120max 120max 120max 140max 160max 160max 160max 120max 150max 150max 150max 160max 180max 180max 180max 50max 120max 150max 240max 20max 48max 60max 96max 100max (ACIN 85V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) Fixed ("Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12, 15, 24V t10%) 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 Works over 105% of rating and recovers automatically Works over 115% of rating, by zener diode clamping Not provided Not provided Not provided AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN Complies with FCC-B, VCCI-B 50X17X115mm (WXHXD) / 80g max Convection Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output. Please contact us about safety approvals for the model with option. Avoid prolonged use under over-load. LCA-4 LCA15S External view LCA Performance data STATIC CHARACTERISTICS (LCA15S-5) RISE TIME & FALL TIME (LCA15S-5) OVERCURRENT CHARACTERISTICS (LCA15S-5) DERATING CURVE LCA-5 Ordering information AC-DC Power Supplies Open Frame/Enclosed type LCA30S LC 1 A 30 2 3 S 4 5 Recommended EMI/EMC Filter NAC-06-472 R -5 High voltage pulse noise type : NAP series Low leakage current type : NAM series -O 6 1Series name 2100/120V input 3Output wattage 4Single output 5Output voltage 6Optional *3 C :with Coating G :Low leakage current Y :with Potentiometer *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT LCA30S-3 18 3V 6A LCA30S-5 30 5V 6A LCA30S-12 30 12V 2.5A LCA30S-15 30 15V 2A LCA30S-24 31.2 24V 1.3A LCA30S-36 32.4 36V 0.9A LCA30S-48 33.6 48V 0.7A SPECIFICATIONS INPUT LCA OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 * MODEL VOLTAGE[V] ACIN 100V CURRENT[A] FREQUENCY[Hz] EFFICIENCY[%] INRUSH CURRENT[A] ACIN 100V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 TEMPERATURE REGULATION[mV] *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD LCA30S-3 LCA30S-5 LCA30S-12 LCA30S-15 LCA30S-24 LCA30S-36 LCA30S-48 AC85 - 132 1f or DC110 - 170 0.7typ (Io=100%) 47 - 440 or DC 69typ 75typ 80typ 81typ 82typ 80typ 80typ 25typ (Io=100%) (At cold start) 0.5max (60Hz, According to UL, CSA and DEN-AN) 3 5 12 15 24 36 48 6 6 2.5 2 1.3 0.9 0.7 20max 20max 48max 60max 96max 144max 192max 40max 40max 100max 120max 150max 240max 300max 80max 80max 120max 120max 120max 150max 150max 140max 140max 160max 160max 160max 200max 200max 120max 120max 150max 150max 150max 250max 350max 160max 160max 180max 180max 180max 300max 400max 50max 50max 120max 150max 240max 360max 480max 20max 20max 48max 60max 96max 144max 192max 100max (ACIN 85V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12, 15, 24, 36, 48V t10%) 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 34.5 - 37.5 46.0 - 50.0 xx Works over 105% of rating and recovers automatically 4.00V min Works over 115% of rating, by zener diode clamping Not provided Not provided Not provided AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN Complies with FCC-B, VCCI-B 50X25X132.5mm (WXHXD) / 150g max Convection Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output. Please contact us about safety approvals for the model with option. Avoid prolonged use under over-load. LCA-6 LCA30S External view LCA Performance data STATIC CHARACTERISTICS (LCA30S-5) RISE TIME & FALL TIME (LCA30S-5) OVERCURRENT CHARACTERISTICS (LCA30S-5) DERATING CURVE LCA-7 Ordering information AC-DC Power Supplies Open Frame/Enclosed type LCA50S LC 1 A 2 50 3 S 4 Recommended EMI/EMC Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series -5 5 -O 6 1Series name 2100/120V input 3Output wattage 4Single output 5Output voltage 6Optional *4 C :with Coating G :Low leakage current Y :with Potentiometer *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT LCA50S-3 30 3V 10A LCA50S-5 50 5V 10A LCA50S-12 51.6 12V 4.3A LCA50S-15 52.5 15V 3.5A LCA50S-24 60 24V 2.5A LCA50S-24-H LCA50S-36 60 61.2 24V 2.5A 36V 1.7A LCA50S-48 62.4 48V 1.3A SPECIFICATIONS LCA INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 MODEL VOLTAGE[V] CURRENT[A] ACIN 100V FREQUENCY[Hz] EFFICIENCY[%] INRUSH CURRENT[A] ACIN 100V LEAKAGE CURRENT[mA] VOLTAGE[V] *3 CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD LCA50S-3 LCA50S-5 LCA50S-12 LCA50S-15 LCA50S-24 LCA50S-24-H LCA50S-36 LCA50S-48 AC85 - 132 1f or DC110 - 170 1.3typ (Io=100%) 47 - 440 or DC 71typ 78typ 80typ 81typ 82typ 82typ 82typ 82typ 30typ (Io=100%) (At cold start) 0.5max (60Hz, According to UL, CSA and DEN-AN) 3 5 12 15 24 24 36 48 10 10 4.3 3.5 2.5 2.5 (Peak 3) 1.7 1.3 20max 20max 48max 60max 96max 96max 144max 192max 40max 40max 100max 120max 150max 150max 240max 300max 80max 80max 120max 120max 120max 120max 150max 150max 140max 140max 160max 160max 160max 160max 200max 200max 120max 120max 150max 150max 150max 150max 250max 350max 160max 160max 180max 180max 180max 180max 300max 400max 50max 50max 120max 150max 240max 240max 360max 480max 60max 60max 150max 180max 290max 290max 450max 600max 20max 20max 48max 60max 96max 96max 144max 192max 200max (ACIN 85V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as optional: 5, 12, 15, 24, 36, 48V t10%) 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 23.0 - 25.0 34.5 - 37.5 46.0 - 50.0 xx Works over 105% of rating (works over 105% of peak current at option -H) and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating Not provided Not provided Not provided AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN Complies with FCC-B, VCCI-B 50X25X195mm (WXHXD) / 200g max Convection Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output. Peak load for 10 sec. or less is acceptable(The average current has to be less than the rated current). Please contact us about safety approvals for the model with option. LCA-8 LCA50S External view LCA Performance data STATIC CHARACTERISTICS (LCA50S-5) RISE TIME & FALL TIME (LCA50S-5) OVERCURRENT CHARACTERISTICS (LCA50S-5) DERATING CURVE LCA-9 Ordering information AC-DC Power Supplies Open Frame/Enclosed type LCA75S LC 1 A 2 75 3 S 4 Recommended EMI/EMC Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series -5 5 -O 6 1Series name 2100/120V input 3Output wattage 4Single output 5Output voltage 6Optional *4 C :with Coating G :Low leakage current Y :with Potentiometer *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT LCA75S-3 45 3V 15A LCA75S-5 75 5V 15A LCA75S-12 75.6 12V 6.3A LCA75S-15 75 15V 5A LCA75S-24 76.8 24V 3.2A LCA75S-24-H LCA75S-36 76.8 75.6 24V 3.2A 36V 2.1A LCA75S-48 76.8 48V 1.6A SPECIFICATIONS LCA INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 MODEL VOLTAGE[V] CURRENT[A] ACIN 100V FREQUENCY[Hz] EFFICIENCY[%] INRUSH CURRENT[A] ACIN 100V LEAKAGE CURRENT[mA] VOLTAGE[V] *3 CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD LCA75S-3 LCA75S-5 LCA75S-12 LCA75S-15 LCA75S-24 LCA75S-24-H LCA75S-36 LCA75S-48 AC85 - 132 1f or DC110 - 170 1.9typ (Io=100%) 47 - 440 or DC 72typ 79typ 81typ 83typ 84typ 84typ 84typ 84typ 30typ (Io=100%) (At cold start) 0.5max (60Hz, According to UL, CSA and DEN-AN) 3 5 12 15 24 24 36 48 15 15 6.3 5 3.2 3.2 (Peak 4.2) 2.1 1.6 20max 20max 48max 60max 96max 96max 144max 192max 40max 40max 100max 120max 150max 150max 240max 300max 80max 80max 120max 120max 120max 120max 150max 150max 140max 140max 160max 160max 160max 160max 200max 200max 120max 120max 150max 150max 150max 150max 250max 350max 160max 160max 180max 180max 180max 180max 300max 400max 50max 50max 120max 150max 240max 240max 360max 480max 60max 60max 150max 180max 290max 290max 450max 600max 20max 20max 48max 60max 96max 96max 144max 192max 200max (ACIN 85V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as optional: 5, 12, 15, 24, 36, 48V t10%) 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 23.0 - 25.0 34.5 - 37.5 46.0 - 50.0 xx Works over 105% of rating (works over 105% of peak current at option -H) and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating Not provided Not provided Not provided AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN Complies with FCC-B, VCCI-B 50X32X222mm (WXHXD) / 300g max Convection Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output. Peak load for 10 sec. or less is acceptable(The average current has to be less than the rated current). Please contact us about safety approvals for the model with option. LCA-10 LCA75S External view LCA Performance data STATIC CHARACTERISTICS (LCA75S-5) RISE TIME & FALL TIME (LCA75S-5) OVERCURRENT CHARACTERISTICS (LCA75S-5) DERATING CURVE LCA-11 Ordering information AC-DC Power Supplies Open Frame/Enclosed type LCA100S LC 1 A 2 100 3 S 4 Recommended EMI/EMC Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT LCA100S-3 60 3V 20A LCA100S-5 100 5V 20A -5 5 -O 6 1Series name 2100/120V input 3Output wattage 4Single output 5Output voltage 6Optional *4 C :with Coating G :Low leakage current S :with Chassis SN :with Chassis & cover Y :with Potentiometer LCA100S-12 LCA100S-15 LCA100S-24 LCA100S-24-H LCA100S-36 LCA100S-48 102 105 103.2 103.2 108 105.6 12V 8.5A 15V 7A 24V 4.3A 24V 4.3A 36V 3A 48V 2.2A SPECIFICATIONS LCA INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 * MODEL VOLTAGE[V] CURRENT[A] ACIN 100V FREQUENCY[Hz] EFFICIENCY[%] INRUSH CURRENT[A] ACIN 100V LEAKAGE CURRENT[mA] VOLTAGE[V] *3 CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD LCA100S-3 LCA100S-5 LCA100S-12 LCA100S-15 LCA100S-24 LCA100S-24-H LCA100S-36 LCA100S-48 AC85 - 132 1f or DC110 - 170 2.5typ (Io=100%) 47 - 440 or DC 74typ 79typ 83typ 84typ 85typ 85typ 85typ 85typ 15typ (Io=100%) 0.5max (60Hz, According to UL, CSA and DEN-AN) 3 5 12 15 24 24 36 48 20 20 8.5 7 4.3 4.3 (Peak 7) 3 2.2 20max 20max 48max 60max 96max 96max 144max 192max 40max 40max 100max 120max 150max 150max 240max 300max 80max 80max 120max 120max 120max 120max 150max 150max 140max 140max 160max 160max 160max 160max 200max 200max 120max 120max 150max 150max 150max 250max 250max 350max 160max 160max 180max 180max 180max 280max 300max 400max 50max 50max 120max 150max 240max 240max 360max 480max 60max 60max 150max 180max 290max 290max 450max 600max 20max 20max 48max 60max 96max 96max 144max 192max 200max (ACIN 85V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 - 3.6 4.5 - 5.5 Fixed ("Y"which can be adjusted the output is available as optional: 12, 15, 24, 36, 48V t10%) 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 23.0 - 25.0 34.5 - 37.5 46.0 - 50.0 xx xx Works over 105% of rating (works over 105% of peak current at option -H) and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating Not provided Not provided Not provided AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN Complies with FCC-B, VCCI-B 62X32X222mm (WXHXD) / 370g max (without chassis and cover) Convection Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output. Peak load for 20 sec. or less is acceptable(The average current has to be less than the rated current). Please contact us about safety approvals for the model with option. Derating is required when operated with chassis and cover. LCA-12 LCA100S External view LCA Performance data STATIC CHARACTERISTICS (LCA100S-5) RISE TIME & FALL TIME (LCA100S-5) OVERCURRENT CHARACTERISTICS (LCA100S-5) DERATING CURVE LCA-13 Ordering information AC-DC Power Supplies Open Frame/Enclosed type LCA150S LC 1 A 2 150 3 S 4 Recommended EMI/EMC Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT LCA150S-3 90 3V 30A LCA150S-5 150 5V 30A -5 5 -O 6 1Series name 2100/120V input 3Output wattage 4Single output 5Output voltage 6Optional *4 C :with Coating G :Low leakage current S :with Chassis SN :with Chassis & cover Y :with Potentiometer LCA150S-12 LCA150S-15 LCA150S-24 LCA150S-24-H LCA150S-36 LCA150S-48 150 150 151.2 151.2 151.2 153.6 12V 12.5A 15V 10A 24V 6.3A 24V 6.3A 36V 4.2A 48V 3.2A SPECIFICATIONS LCA INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 * MODEL VOLTAGE[V] CURRENT[A] ACIN 100V FREQUENCY[Hz] EFFICIENCY[%] INRUSH CURRENT[A] ACIN 100V LEAKAGE CURRENT[mA] VOLTAGE[V] *3 CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD LCA150S-3 LCA150S-5 LCA150S-12 LCA150S-15 LCA150S-24 LCA150S-24-H LCA150S-36 LCA150S-48 AC85 - 132 1f or DC110 - 170 3.6typ (Io=100%) 47 - 440 or DC 72typ 79typ 82typ 83typ 85typ 85typ 85typ 85typ 15typ (Io=100%) 0.5max (60Hz, According to UL, CSA and DEN-AN) 3 5 12 15 24 24 36 48 30 30 12.5 10 6.3 6.3 (Peak 10) 4.2 3.2 20max 20max 48max 60max 96max 96max 144max 192max 40max 40max 100max 120max 150max 150max 240max 300max 80max 80max 120max 120max 120max 120max 150max 150max 140max 140max 160max 160max 160max 160max 200max 200max 120max 120max 150max 150max 150max 150max 250max 350max 160max 160max 180max 180max 180max 180max 300max 400max 50max 50max 120max 150max 240max 240max 360max 480max 60max 60max 150max 180max 290max 290max 450max 600max 20max 20max 48max 60max 96max 96max 144max 192max 200max (ACIN 85V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 - 3.6 4.5 - 5.5 Fixed ("Y"which can be adjusted the output is available as optional: 12, 15, 24, 36, 48V t10%) 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 23.0 - 25.0 34.5 - 37.5 46.0 - 50.0 xx xx Works over 105% of rating (works over 105% of peak current at option -H) and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating Not provided Not provided Not provided AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN Complies with FCC-B, VCCI-B 75X36X222mm (WXHXD) / 550g max (without chassis and cover) Convection Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output. Peak load for 15 sec. or less is acceptable(The average current has to be less than the rated current). Please contact us about safety approvals for the model with option. Derating is required when operated with chassis and cover. LCA-14 LCA150S External view LCA Performance data STATIC CHARACTERISTICS (LCA150S-5) RISE TIME & FALL TIME (LCA150S-5) OVERCURRENT CHARACTERISTICS (LCA150S-5) DERATING CURVE LCA-15