103SRI3A-2 pace | OF | REPLACES MI | RELEASE wo.PR- 4600 DRAWING NUMBER 7 ISSUE REVISIONS | cHECK AJ 201747 JLH DECOO CHECK 21DEC89 CHECK PTC/CAD| 2D) DRAWN | 13NOV89 JAS i 3X .240+ .030 | CABLE Z2\ 39. 3704. 300 ! /\ | 4 15/32-32 \ 2X HEX NUT |. 000+. 040 2 Qf FIG. 2 OPERATE ' ' 3X 22 GAUGE CONDUCTOR UNS-2A SENSING FACE /0\ SENSOR WILL +V5 BE LOCATED ANYWHERE WITHIN @.050 SWITCH SYMBOL ANS | YI4.9M-1982 APPLIES 4.5 10 24 VDC UNIPOLAR DEVICE SEDEESE> Ds OPERATING CHARACTERISTICS ZNVA GAUSS OPERATE MAX 4995 RELEASE MIN 200 DIFF MIN 39 ABSOLUTE MAXIMUM RATINGS MI 1O3SRI3A-2 SUPPLY VOLTAGE (Vs) -1.0 VDC TO +25.0 VDC VOLTAGE EXTERNALLY APPLIED TO OUTPUT +25 VOLTS DC MAX WITH SWITCH -0.5 VOLTS MAX WITH SWITCH IN "OFF" IN "OFF" CONDITION ONLY OR "ON" CONDITION OUTPUT CURRENT 40 mA (SINK PER QUITPUT) TEMPERATURE OPERATE AND STORAGE -40C TO 100C MAGNETIC FLUX NO LIMIT, THE CIRCUIT CANNOT BE DAMAGED BY MAGNETIC OVERDRIVE ELECTRICAL CHARACTERISTICS MIN TYP MAX REMARKS SUPPLY CURRENT /I\ 10.0 mA [ON CONDITION OUTPUT VOLTAGE 0.4 V SINKING 20 mA PER OUTPUT (OPERATED) /4\ OUTPUT LEAKAGE POU A LEAKAGE INTO SWITCH OUTPUT CURRENT (RELEASED) /4\ OUTPUT SWITCHING TIME (SINKING 20 mA) RISE TIME /4\ |.5u SEC | 10% TO 90% FALL TIME 0.5uSFC 190% TO 10% NOTE: CAPACITOR ACROSS THE OPERATION CONTINUES, THAT MICRO SWITCH MANUFACTURES. FIELD REPRESENTATIVE FOR INFORMATION. INSTALLATION, INPUT TERMINALS (0.1 MFD). YOU MAY HAVE TO USE THE THIS DEVICE IS NOT PROTECTED AGAINST HIGH ELECTRICAL NOISE. IF ERRATIC OPERATION OCCURS AFTER INSTALL A IF ERRATIC INDUSTRIAL DEVICES PLEASE CONTACT YOUR LOCAL 5FVs (+) RED WIRE HALL TRIGGER CIRCUIT SENSOR AND OUTPUT (0) NORMALLY HIGH WHITE WIRE AMPLIFIER ) >GROUND (-) BLACK WIRE BLOCK DIAGRAM SHOWING CURRENT SINKING OUTPUTS a rm ~Y FLUX ENTERING THE SOUTH POLE OF THE MAGNET WILL OPERATE THE SENSOR WHEN MAGNET IS POSITIONED AS SHOWN IN FIGURE 2. THIS ASSUMES THE CONVENTION THAT THE DIRECTION OF THE EXTERNAL FLUX OF A MAGNET IS FROM THE NORTH TO THE SOUTH POLE OF THE MAGNET 22 GAUGE PVC DATE CODE LOCATED IN THIS AREA FROM -40 C TO 100 AND 4.5 TO 24 VOLTS CATALOG LISTING LOCATED SENSITIVE AREA IS LOCATED AT 24242C IN THIS AREA INSULATED CONDUCTORS WITH MOLDED PVC JACKET 050 BEHIND THE SENSING FACE Vs IS THE UNREGULATED SUPPLY VOLTAGE JACKET IS CUT BACK 1.317 INCHES FROM FREE END OF LEADS ELECTROSTATIC SENSITIVE DEVICES DO NOT OPEN OR HANDLE EXCEPT AT A STATIC FREE WORKSTATION ESD SENSITIVITY: CLASS 3 THIRD ANGLE PROJECTION = z+ SCALE 3: DO NOT SCALE PRINT UNLESS OTHERWISE SPECIFIED TOLERANCES ARE THIS DRAWING COVERS A PROPRIETARY ITEM AND IS THE PROPERTY OF MICRO SWITCH. HONEYWELL. THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL OF MICRO SWITCH. A DIVISION OF MUCHO SWIG a Honeywell Division FED. MFG. CODE 91929 MAGNETICALLY OPERATED CYLINDRICAL HALL SWITCH CATALOG LISTING 1O3SRI3A-2 ONE PLACE (.0) t 030 TWO PLACES (.00) t.015 THREE PLACES (.000) t 005 ANGLES t WE | GHT