63
140 rue Eugene Delacroix
91211 Draveil cedex 1, France
33-1-69-83-78-00
33-1-69-42-05-70 fax
600 S. Parker Street • P.O. Box 909
Elm City, NC 27822
252-236-4311 • 252-236-3613 fax
800-644-4547
Berk-Tek Electronics Cable
www.nexansbtec.com
6
MIL-C-7078
This specification consists of a series of specifications or slash sheets, covering electrical cable typically used in aerospace
applications. The cables may be ordered unshielded, unjacketed, just a shield, or shielded and jacketed. Each slash sheet will
specify exactly what type insulation and outer covering.
Cable constructions ordered to MIL-C-7078 will have to be color coded and identified in accordance with the specification.
Military Cable Specifications
M-7078/X -YY- Z
Number of basic wires in cable
Size of individual wires
Number of specifications
Part numbers are coded as stated below:
Cable Specifications
Nexans part no. Description Voltage Temp.
M7078/8 Basic wires to M81381/11, TPC shielded, polyimide tape jacket 600 150°C
M7078/9 Basic wires to M81381/12, TPC shielded, polyimide tape jacket 600 150°C
M7078/10 Basic wires to M81381/13, TPC shielded, polyimide tape jacket 600 150°C
M7078/11 Basic wires to M81381/11, NPC shielded, polyimide tape jacket 600 200°C
M7078/12 Basic wires to M81381/12, NPC shielded, polyimide tape jacket 600 200°C
M7078/13 Basic wires to M81381/13, NPC shielded, polyimide tape jacket 600 200°C
M7078/14 Basic wires to M81381/14, NPC shielded, polyimide tape jacket 600 200°C
M7078/15 Basic wires to M81381/11, Unshielded and unjacketed 600 200°C
M7078/16 Basic wires to M81381/12, Unshielded and unjacketed 600 200°C
M7078/17 Basic wires to M81381/13, Unshielded and unjacketed 600 200°C
M7078/18 Basic wires to M81381/14, Unshielded and unjacketed 600 200°C
M7078/26 Basic wires to M81381/8, NPC shield, polyimide tape jacket 600 200°C
M7078/27 Basic wires to M81381/8, Unshielded and unjacketed 600 200°C
M7078/28 Basic wires to M81381/10, NPC shielded, polyimide tape jacket 600 200°C
M7078/29 Basic wires to M81381/10, Unshielded and unjacketed 600 200°C
MIL-DTL-27072
This specification covers non-portable multi-conductor cable for interior applications where the material will be somewhat
protected. The type of protection may include racks, tunnels or within trailers or equipment.
Detailed requirements for individual types of cable, such as wire gauge, number of conductors or types of shield and
jacket, are called out on each specification or slash sheet.
For cables not specified in the specification supplement, design data must be submitted to the procuring activity for
approval. The Nexans customer service department should be consulted about particular specifications and requirements.
MIL-DTL-55021
This specification covers insulated electrical hook-up wire (jacketed, unjacketed, shielded and unshielded) in twisted pair
and triples for application in internal wiring of electrical equipment at medium temperatures(-40°C to 105°C) and high tem-
peratures (-65°C to 200 °C).
Detailed requirements for individual cables are called out on each specification. For additional information on a particu-
lar specification or for pricing information contact the Nexans customer services department.