BDL26100 Product data sheet Characteristics PowerPact - circuit breaker - 100A 2P AC 14kA at 600Y/347 V (UL) - EverLink lug Product availability : Stock - Normally stocked in distribution facility Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications Price* : 956.00 USD Main Range PowerPact Product name PowerPact B Device short name BD 100 Product or component type Circuit breaker Device application Distribution Complementary Line Rated Current 100 A Number of Poles 2P Protected poles description 2t Control type Toggle Breaking capacity code D Breaking capacity 25 kA at 240 V AC 50/60 Hz according to UL 489 14 kA at 600 V AC 50/60 Hz according to UL 489 18 kA at 600Y/347 V AC 50/60 Hz according to UL 489 20 kA at 250 V DC 50/60 Hz according to UL 489 Icu : 25 kA at 480/277 V AC 50/60 Hz according to IEC 60947-2 25 kA at 480 V AC 50/60 Hz according to UL 489 18 kA at 125 V DC 50/60 Hz according to UL 489 18 kA at 250 V DC 50/60 Hz according to UL 489 System Voltage 240 V AC 50/60 Hz according to IEC 60947-2 347 V AC 50/60 Hz according to UL 489 125 V DC 50/60 Hz according to UL 489 250 V DC 50/60 Hz according to UL 489 [Ics] rated service breaking capacity 25 kA: at 220...240 V AC 50/60 Hz according to IEC 60947-2 18 kA: at 380...415 V AC 50/60 Hz according to IEC 60947-2 18 kA: at 440 V AC 50/60 Hz according to IEC 60947-2 14 kA: at 500...525 V AC 50/60 Hz according to IEC 60947-2 [Uimp] rated impulse withstand voltage 8 kV according to IEC 60947-2 [Ui] rated insulation voltage 800 V according to IEC 60947-2 Jul 10, 2019 1 Trip unit technology Thermal-magnetic Trip unit name TM-D Suitability for isolation Yes according to IEC 60947-2 Utilisation category Category A Mechanical durability 20000 cycles according to IEC 947-1 Annex K ed 5.2 Electrical durability 10000 cycles according to IEC 947-1 Annex K ed 5.2 In at 440 V Connection pitch 1.06 in (27 mm) Local signalling Green flag presence of auxiliary contacts Mounting mode By screws plate Clip-on 35 x 15 mm symmetrical DIN rail Electrical connection Everlink lug at line Everlink lug at load AWG gauge AWG 6...AWG 2/0 fine stranded (aluminium/copper) AWG 14...AWG 3/0 rigid or stranded (aluminium/copper) Tightening torque 44.25 lbf.in (5 N.m) 0...0.02 in (2.5...16 mm) (AWG 14...AWG 4) 79.65 lbf.in (9 N.m) 0.04...0.15 in (25...95 mm) (AWG 3...AWG 3/0) Number of slots 1 auxiliary switch OF (plug-in) 1 voltage release MN or MX (plug-in) Power wire stripping length 0.79 in (20 mm) Color Grey (RAL 7016) 9 mm pitches 6 Height 5.39 in (137 mm) Width 2.13 in (54 mm) Depth 3.15 in (80 mm) Product weight 1.7 lb(US) (0.769 kg) Quantity per set Set of 1 Continuous current rating 80 % Environment Quality labels CE Standards EN/IEC 60947-2 EN/IEC 60947-5-1 GB 14048.2 NEMA AB1 UL 489 CSA C22.2 No 5 NMX J-266 Product certifications UL CSA CCC EAC NOM IEC IP degree of protection IP40 (front cover) according to IEC 60529 IK degree of protection IK07 according to IEC 62262 Pollution degree 3 according to IEC 60947-1 Ambient air temperature for operation -13...158 F (-25...70 C) Ambient air temperature for storage -58...185 F (-50...85 C) Operating altitude With derating Without derating Ordering and shipping details Category 01130 - BD UNIT MOUNT BREAKER/SWITCH Discount Schedule DE2 GTIN 003606481152923 Nbr. of units in pkg. 1 Package weight(Lbs) 2.1400000000000001 2 Returnability Y Country of origin MX Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 1644 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Product environmental profile Available Product Environmental Profile Product end of life instructions Need no specific recycling operations California proposition 65 WARNING: This product can expose you to chemicals including: - - - - - - - Substance 1 DINP, which is known to the State of California to cause cancer, and - - - - - - - Substance 2 DIDP, which is known to the State of California to cause Birth Defects or other reproductive harm. - - - - - - - More information For more information go to www.p65warnings.ca.gov 3