Wide-Vue Analog
Panel Meters
• UL Recognized - File # E91015
Except for the Wattmeters & Frequency Meters
• Clear acrylic window for wide viewing area
• Rugged black plastic case
• Black spade pointer for easy distant reading
• Optional: Behind-panel mounting bezel kit
Ordering Information
AC Milliammeters Iron Vane Movement
Range
Approx.
Impedance
(Ohms) @ 60 Hz
Model / Size and Catalog No.
2 - 1/2”
Model 1257 3 - 1/2”
Model 1357 4 - 1/2”
Model 1359
0 - 10 1,650 06294 06625 06665
0 - 50 80 06295 06630 06670
0 - 100 17.2 06296 06640 06680
0 - 250 3.15 06297 06650 06690
0 - 500 0.9 06300 06660 06699
0 - 1000 .213 < > 35065 < >
< > Available on special order
1 Rev. 05-18
Wide-Vue Analog
Panel Meters
AC Ammeters Iron Vane Movement
Range
Approx.
Impedance
(Ohms ) @ 60Hz
Model / Size and Catalog No.
2 - 1/2”
Model 1257 3 - 1/2”
Model 1357 4 - 1/2”
Model 1359
0 - 1 .213 02560 03130 03260
0 - 1.5 .105 02570 03140 03270
0 - 2 .065 < > 03150 03280
0 - 3 .025 02575 03160 03290
0 - 5 .008 02580 03170 03300
0 - 10 .004 02590 03180 03310
0 - 10 .008 < > 35073 * 35077 *
0 - 15 .0025 02599 03190 03320
0 - 25 .002 02609 03200 03330
0 - 25 .008 < > 35074 * 35078 *
0 - 30 .0015 02615 03205 03335
0 - 50 .001 02619 03210 03340
0 - 50 .008 < > 35075 * 35079 *
0 - 75 .0002 < > 03215 03345
0 - 75 .008 < > 35076 * 35080 *
0 - 100 .008 02622 * 03220 * 03350 *
0 - 150 .008 02624 * 03230 * 03360 *
0 - 200 .008 02626 * 03240 * 03370 *
0 - 300 .008 02627 * 03250 * 03380 *
< > Available on special order
Ordering Information
* These meters are 5 amp meters
to be used with an external
current transformer.
Additional current transformer
ranges can be achieved through
wrapping the primary and
secondary wires.
AC Dual Range Ammeter/Voltmeter
Range
Approx.
Impedance
(Ohms) @ 60 Hz
Model / Size and Catalog No.
2 - 1/2”
Model 1257 3 - 1/2”
Model 1357 4 - 1/2”
Model 1359
0 - 150V
and 0 - 5A 15030
and .021 --------- 03129 03259
< > Available on special order
2 Rev. 05-18
Ordering Information
Wide-Vue Analog
Panel Meters
Self-Shielding Movement
Range
Approx.
Impedance
(Ohms) @ 60 Hz
Model / Size and Catalog No.
2 - 1/2”
Model 1247 3 - 1/2”
Model 1347 4 - 1/2”
Model 1349
0 - 5
2000
Ohms
Per
Volt
10015 10020 10090
0 - 10 10016 10030 10100
0 - 15 < > 10040 10110
0 - 50 < > 10050 10120
0 - 150 10017 10060 10130
0 - 300 10018 10070 10140
< > Available on special order
AC Voltmeters Iron Vane Movement
Range
Approx.
Impedance
(Ohms) @ 60 Hz
Model / Size and Catalog No.
2 - 1/2”
Model 1257 3 - 1/2”
Model 1357 4 - 1/2”
Model 1359
0 - 5 33 < > 10160 10260
0 - 10 133 09670 10170 10270
0 - 15 300 09675 10180 10280
0 - 25 833 09680 10190 10290
0 - 50 3,333 09690 10200 10300
0 - 100 16,333 09695 10210 10310
0 - 150 25,000 09700 10220 10320
0 - 250 41,166 09705 10230 10330
0 - 300 50,000 09710 10240 10340
0 - 500 83,333 09715 * 10250 * 10350 *
< > Available on special order
* External multipliers (model 183)
are furnished on AC meters having
a range of 500 volts or higher.
3 Rev. 05-18
DC Microammeters Self-Shielding Movement
Range
Approx.
Impedance
(Ohms) @ 60 Hz
Model / Size and Catalog No.
1 - 1/2”
Model 1212 2 - 1/2”
Model 1227 3 - 1/2”
Model 1327 4 - 1/2”
Model 1329
0 - 50 1800 (5500) * 04294 04310 04380 04480
0 - 100 1800 04295 04320 04390 04490
0 - 200 1100 04296 04330 04400 04500
0 - 500 90 (190) * 04297 04340 04410 04510
25 -0-25 1800 04298 < > 04420 04520
50-0-50 1800 (5500) * 04302 04350 04430 04530
100-0-100 1100 04300 04351 04440 04540
500-0-500 43 04301 04352 04450 04550
* Impedance of Model 1212 shown in ( )
< > Available on special order
Ordering Information
Wide-Vue Analog
Panel Meters
DC Taut-Band Microammeters Self Shielding Movement
Range
Approx.
Impedance
(Ohms) @ 60 Hz
Model / Size and Catalog No.
1 - 1/2”
Model 1212T 2 - 1/2”
Model 1227T 3 - 1/2”
Model 1327T 4 - 1/2”
Model 1329T
0 - 10 4900 < > 04303 04359 04459
0 - 15 1960 (5500) * 04601 04304 04361 04461
0 - 25 1960 04602 04306 04371 04471
0 - 50 960 04603 04311 04381 04481
0 - 100 500 04604 04321 04391 04491
0 - 200 234 04605 04331 04401 04501
* Impedance of Model 1212 shown in ( )
< > Available on special order
4 Rev. 05-18
Ordering Information
Wide-Vue Analog
Panel Meters
DC Milliammeters Self-Shielding Movement
Range
Approx.
Impedance
(Ohms) @ 60 Hz
Model / Size and Catalog No.
1 - 1/2”
Model 1212 2 - 1/2”
Model 1227 3 - 1/2”
Model 1327 4 - 1/2”
Model 1329
0 - 1 43.0 06163 06175 06310 06470
0 - 3 2.0 < > 06180 06320 06480
0 - 5 2.0 (20) † 06164 06190 06330 06490
0 - 10 10.0 (2.2) † 06165 06200 06340 06495
0 - 15 6.6 (2.2) † 06166 06210 06350 06502
0 - 20 5.0 < > 06215 06360 06524
0 - 25 4.0 (6.0) † 06167 06220 06370 06530
0 - 50 2.0 (3.0) † 06168 06230 06380 06540
0 - 100 1.0 (1.5) † 06169 06240 06390 06550
0 - 150 .66 (1.0) † 06170 06250 06400 06560
0 - 200 .50 (.75) † 06171 06260 06410 06570
0 - 250 .40 (.60) † 06172 06270 06420 06580
0 - 300 .33 (.50) † 06173 06280 06430 06590
0 - 500 .20 (.30) † 06174 06290 06440 06600
0 - 750 .13 < > < > 06450 06610
0 - 1000 .05 < > 06292 06460 06620
† Impedance of Model 1212 shown in ( )
< > Available on special order
DC Ammeters Self-Shielding Movement
Range
Approx.
Impedance
(Ohms) @ 60 Hz
Model / Size and Catalog No.
1 - 1/2”
Model 1212 2 - 1/2”
Model 1227 3 - 1/2”
Model 1327 4 - 1/2”
Model 1329
0 - 1 .050 02431 02440 02640 02820
0 - 1.5 .033 < > 02450 02650 02830
0 - 2 .025 02432 02460 02660 02840
0 - 3 .0166 02433 02470 02670 02850
0 - 5 .010 02434 02480 02680 02860
0 - 10 .005 02435 02490 02690 02870
0 - 15 .0033 * 02436 † 02500 02700 02880
0 - 25 .0020 * 02437 † 02510 02710 02890
0 - 30 .0017 < > 02520 02720 02900
0 - 50 .001 * 02438 † 02530 02730 02910
0 - 100 10.0 < > 02540 † 02740 † 02920 †
0 - 150 10.0 < > 02550 † 02750 † 02930 †
0 - 200 10.0 < > 02552 † 02760 † 02940 †
0 - 300 10.0 < > 02554 † 02770 † 02950 †
0 - 500 10.0 < > < > 02780 † 02960 †
15-0-15 .0033 < > < > 02790 < >
30-0-30 .0017 < > < > 02800 < >
50-0-50 .001 < > < > 02810 < >
† 1 - 1/2” DC current meters
are self-contained through 10
amps.
15 amps and higher are
supplied as 50 mV meters to
be used with external shunts.
2 - 1/2”, 3 - 1/2” and
4 - 1/2 “ DC current meters
are self-contained through 50
amps.
Higher range DC current me-
ters are 50 mV meters to be
used with external shunts.
< > Available on special order
* Model 1212 only - 10 Ohms
5 Rev. 05-18
Ordering Information
Wide-Vue Analog
Panel Meters
Wattmeters / Dynamometer Type Not
Range
Maximum Model / Size and
Catalog No.
Volts Amps 4 - 1/2”
Model 1379
0 - 10 150 .175 10930 *
0 - 20 150 .400 10940 *
0 - 75 150 1.0 10960
0 - 150 150 2.0 10970
0 - 300 150 4.0 10975
0 - 600 300 4.0 10980
0 - 750 150 10.0 10990
0 - 1500 300 10.0 11000
0 - 3000 300 20.0 11010
DC Millivoltmeters Self-Shielding Movement
Range
Approx.
Impedance
(Ohms) @ 60 Hz
Model / Size and Catalog No.
1 - 1/2”
Model 1212 2 - 1/2”
Model 1227 3 - 1/2”
Model 1327 4 - 1/2”
Model 1329
0 - 50 10.0 07005 07010 07020 07030
50-0-50 20.0 < > < > 07021 07031
< > Available on special order
DC Voltmeters Self-Shielding Movement
Range
Approx.
Impedance
(Ohms) @ 60 Hz
Model / Size and Catalog No.
1 - 1/2”
Model 1212 2 - 1/2”
Model 1227 3 - 1/2”
Model 1327 4 - 1/2”
Model 1329
0 - 5
1000
Ohms
Per
Volt
09540 09550 09720 09870
0 - 8 < > < > 09730 09880
0 - 10 09541 09560 09740 09890
0 - 15 09542 09570 09750 09900
0 - 25 09543 09580 09760 09910
0 - 30 09544 09590 09770 09920
0 - 50 09545 09600 09780 09930
0 - 100 09546 09610 09790 09940
0 - 150 09547 09620 09800 09950
0 - 200 < > 09622 09810 09960
0 - 250 < > 09623 09820 09970
0 - 300 < > 09630 09830 09980
0 - 300 2000
Ohms
Per
Volt
09548 < > < > < >
0 - 500 09549 * 09640 09840 09990
0 - 750 < > 09650 * 09850 10000
0 - 1000 < > 09660 * 09860 * 10010 *
< > Available on special order
* External multipliers
(Model 183) are
furnished
on 1 - 1/2” DC Meters
500 volts or higher;
on 2 - 1/2” DC Meters
750 volts or higher;
and on 3 - 1/2” and
4 - 1/2” DC Meters
1000 volts or higher.
All others have
self-contained
multipliers.
* Compensated wattmeters:
Calibrated for either magnetic or non-magnetic
panels and for a frequency of 25 - 125 Hz
6 Rev. 05-18
Ordering Information
Wide-Vue Analog
Panel Meters
Percent Motor Load Meters
Type Rating
Model / Size and Catalog No.
3 - 1/2”
Model 1327 3 - 1/2”
Model 1357 4 - 1/2”
Model 1329 4 - 1/2”
Model 1359
DC (Note 1) 30 mV 07028 07029
AC (Note 2) 5 amps 03171 03301
Note 1: DC load meters require an external shunt and potentiometer (not sup-
SOLHG8VHWRZDWWZLUHZRXQGSRWHQWLRPHWHr.
The appropriate shunt should be selected from accessory section and
ordered separately.
-
LQJ0XOWLSO\WKDWUDWLQJE\DQGVHOHFWDQGRUGHUWKHVKXQWZLWKDQ
amps rating as large or slightly larger than the calculated value.
,QVWDOODWLRQDQGFDOLEUDWLRQLQVWUXFWLRQVDUHLQFOXGHGZLWKWKHPHWHU
Note 2: $&ORDGPHWHUVPXVWEHXVHGZLWKH[WHUQDOGRQXWWUDQVIRUPHUV
&RPSOHWHLQVWUXFWLRQVIRUSURSHUVHOHFWLRQDUHLQFOXGHGZLWKHDFKAC
load meter.
Advance assistance in selecting the appropriate transformer and deter-
mining the correct primary / secondary turns ratio can be obtained from a
Simpson technical service representative or authorized service center.
0HWHUVFRPHZLWKFRORUFRGHGGLDO
Green 0 - 100% YHOORZ5HG
4 - 20mA Process Meters
Size Scale Model Catalog No.
3 - 1/2” 0 - 100% 1327 35025
4 - 1/2” 0 - 100% 1329 35026
Frequency Meters Self-Shielding Movement Not
Range Voltage
Model / Size and Catalog No.
2 - 1/2”
Model 1287 3 - 1/2”
Model 1387 4 - 1/2”
Model 1389
45 - 55 Hz 120V 35100 35106 35112
55 - 65 Hz 120V 35102 35108 35114
380 - 420 Hz 120V 35104 35110 35116
45 - 55 Hz 240V 35101 35107 35113
55 - 65 Hz 240V 35103 35109 35115
380 - 420 Hz 240V 35105 35111 35117
7 Rev. 05-18
Wide-Vue Analog
Panel Meters
Accuracy
Movement Models 1212, 1212T: Small Core Magnet
Models 1257, 1357, 1359: Iron-vane, magnetically damped
Tracking ± 3%
Shielding Calibration is unaffected by magnetic panel mounting.
Response Time 1.5 seconds maximum
Overload (1 sec.) 10 times F.S.
Overload (Continuous) 1.5 times F.S.
Repeatability 2%: AC Current, DC Process
3%: AC Voltage, DC Voltage, Wattmeters
0.5%: DC Current
Dial Sharp clear scale.
Resistance ± 15% of meter impedance
Operating Temperature - 4ºF to + 149ºF (- 20ºC to + 65ºC)
Case High density black plastic
Pointer Model 1212: Black lance
Scale Length Model 1212, 1212T: 1.50” (38.1mm)
Model 1227, 1227T, 1247, 1257: 2.30” (58.4mm)
Model 1327, 1327T, 1347, 1357, 1377: 3.14” (79.9mm)
Model 1329, 1329T, 1349, 1359, 1379: 3.93” (100mm)
Net Weight Model 1212, 1212T: 2 oz. (0.06 kg)
Model 1257: 4 oz. (0.11 kg)
Model 1359: 5 oz. (0.14 kg)
Model 1227, 1227T: 6 oz. (0.17 kg)
Model 1327, 1327T, 1347: 8 oz. (0.23 kg)
Model 1329, 1329T, 1349, 1377: 9 oz. (0.26 kg)
Model 1379: 10 oz. (0.28 kg)
8 Rev. 05-18
Wide-Vue Analog
Panel Meters
Dimensions
1 - 1/2” Model 1212, 1212T 2 - 1/2” Model 1287
2 - 1/2” Model 1227, 1227T, 1247, 1257 4 - 1/2” Model 1329, 1329T, 1349, 1359
3 - 1/2” Model 1387 4 - 1/2” Model 1389
9 Rev. 05-18
Wide-Vue Analog
Panel Meters
Dimensions
4 - 1/2” Model 1379 3 - 1/2” Model 1327, 1327T, 1347, 1357
10 Rev. 05-18
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Simpson:
02510 02590 02550 02554 02552 02599 02730 02770 02790 02720 02750 02760 02710 09600 09650
09640 09675 09695 09620 09623 09610 09660 09680 09670 09622 09690 09740 09705 09780 09720
09750 09730 09760 06190 09700 09770 10060 10020 06390 06350 06310 06370 10330 10350 10310
02627 02622 02660 02624 02626 09790 09710 09715 35104 35117 35113 35115 35111 35102 35109
35114 35107 35101 35105 35103 35116 35108 35106 35100 35112 35110 04540 09570 04300 09580
04304 04303 04306 04301 09550 09590 04302 07005 07021 07031 07010 07030 07028 07020 07029
02570 02520 02540 02530 02580 02560 02575 02500 02890 02810