E-Series 2-Way 90° Power Divider
112-168 MHz
Rev. V2
MAPD-009850-HW1268
1
1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
1
Features
2-way
90 Degree
Surface Mount
Tape and reel packaging available
260°C Reflow Compatible
RoHS* compliant
Description
M/A-COM’s MAPD-009850-HW1268 is a RoHS Com-
pliant 2-way 90˚ power divider in a low cost, surface
mount package. Ideally suited for high volume cellular,
wireless applications.
The MAPD-009850-HW1268 is available in a SM-89
surface mount package and is designed to be utilized
in both RoHS and standard reflow profiles. Parts are
packaged in tape & reel.
Ordering Information
Part Number Package
MAPD-009850-HW1268 Tape and Reel (900 piece Reel)
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
Pin Configuration
Pin No. Function
Input 1
Port 1 4
Port 2 6
External 50 Ohms 3
Not Connected 2,5
Absolute Maximum Ratings 1,2
Parameter Absolute Maximum
Impedance 50 Ohms nominal
RF Power 1 Watt
Internal Load Dissipation 0.125 Watt
Operating Temperature -40°C to +85°C
Storage Temperature -55°C to +125°C
1. Exceeding any one or combination of these limits may cause permanent damage to this device.
2. M/A-COM does not recommend sustained operation near these survivability limits.
Electrical Specifications: TA = 25°C, Z0 = 50
Frequency Range Test Conditions Units Min. Typ. Max.
Insertion Loss 112 - 168 MHz dB 0.5 1.2
Isolation 112 - 168 MHz dB 18 23
Amplitude Unbalance 112 - 168 MHz dB 1.0 2.0
Phase Unbalance 112 - 168 MHz 0
Input Return Loss 112 - 168 MHz dB 20 24
Product Image
E-Series 2-Way 90° Power Divider
112-168 MHz
Rev. V2
MAPD-009850-HW1268
2
2
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
2
Typical Performance Curves
Insertion Loss Port 1
Insertion Loss port 2
Amplitude Unbalance Phase Unbalance
Isolation
-1.5
-1
-0.5
0
0.5
1
112 120 128 136 144 152 160 168
MHz
dB
-1.5
-1
-0.5
0
0.5
1
112 120 128 136 144 152 160 168
MHz
dB
-3
-2
-1
0
1
2
3
112 120 128 136 144 152 160 168
MHz
-90
-89
-88
-87
112 120 128 136 144 152 160 168
MHz
Degree
-25
-23
-21
-19
-17
-15
112 120 128 136 144 152 160 168
MHz
dB
-30
-25
-20
-15
-10
112 120 128 136 144 152 160 168
MHz
dB
Input Return Loss
SM - 89 Package
Dimensions are inches (millimeters) ± 0.015 (0.38) unless otherwise specified.
E-Series 2-Way 90° Power Divider
112-168 MHz
Rev. V2
MAPD-009850-HW1268
3
3
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
3
M/A-COM Technology Solutions Inc. All rights reserved.
Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM")
products. These materials are provided by MACOM as a service to its customers and may be used for
informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,
to any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM
customers using or selling MACOM products for use in such applications do so at their own risk and agree to