Disconnect switches Index Di s sw con itc nec he t s 18 - Disconnect switches Non-fusible disconnect switches..........................18.1 - 18.18 Accessories for double throw switches........................................................................18.17 Base & DIN rail mounted, 16 - 3150A.............................................................................18.5 Cable operated flange, 30 - 200A.................................................................................18.14 Description......................................................................................................................18.1 Door mounted switches, 16 - 100A..............................................................................18.11 Double throw switches, 16 - 600A................................................................................18.15 Handles & shafts for double throw switches................................................................18.16 OT800 - 1200A, New product coming soon!................................................................18.18 Selection guide, OT16F3 - OT160E3..............................................................................18.2 Selection guide, OT200-600, OETL--NF800A-3150.......................................................18.3 Selection information......................................................................................................18.4 Shaft operated flange, 30 - 100A..................................................................................18.13 Special configurations.......................................................................................18.16, 18.17 Special configurations, 16 - 600A.................................................................................18.15 Special configurations, 30 - 100A.................................................................................18.13 Special configurations, 30 - 200A.................................................................................18.14 Standard handles & shafts.....................................................................................18.6, 18.7 Standard non-fusible accessories..............................................................18.10, 18.8, 18.9 Standard non-fusible accessories for door mounted switches....................................18.12 Fusible disconnect switches................................18.19 - 18.36 Selection BS fuse pattern, 20 - 800A...........................................................................................18.32 Base & DIN rail mounted, 30 - 800A.............................................................................18.22 Cable operated flange, 30 - 200A.................................................................................18.29 DIN fuse pattern, 32 - 800A..........................................................................................18.33 High speed fuse pattern....................................................................................18.30, 18.31 NFC fuse pattern, 63 - 125A.........................................................................................18.34 OS800, New product coming soon!.............................................................................18.35 Other configurations..........................................................................................18.30, 18.31 Other configurations, 20 - 800A....................................................................................18.32 Other configurations, 32 - 800A....................................................................................18.33 Other configurations, 63 - 125A....................................................................................18.34 Selection guide, OS30AFCC12 - OES800L3................................................................18.20 Selection information....................................................................................................18.21 Shaft operated flange, 30 - 100A..................................................................................18.28 Special configurations, 30 - 100A......................................................................18.28, 18.29 Special type fuses.........................................................................................................18.30 Description..............................................................................................18.19, 18.23, 18.24 Accessories Accessories for base & DIN rail mounted switches................................18.25, 18.26, 18.27 Additional poles............................................................................................................18.26 Auxiliary contacts..........................................................................................................18.25 Fuse carriers/covers.....................................................................................................18.26 Fuse monitors...............................................................................................................18.26 Locking accessories.....................................................................................................18.27 Replacement parts........................................................................................................18.27 Shaft accessories..........................................................................................................18.27 Shorting bars................................................................................................................18.27 Standard fusible accessories..................................................................18.25, 18.26, 18.27 T type fuse adaptor kit..................................................................................................18.27 Terminal lugs.................................................................................................................18.25 Terminal shrouds...........................................................................................................18.26 Enclosed disconnect switches............................18.37 - 18.56 Selection 2 & 4 Pole, 30 - 800A....................................................................................................18.54 2 pole, 125 - 3150A......................................................................................................18.46 3 pole bypass, 16 - 1200A............................................................................................18.50 3 pole double throw, 16 - 1200A...................................................................................18.49 3 pole mechanically interlocked, 16 - 1200A................................................................18.51 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 3 pole, 16 - 3150A........................................................................................................18.45 3 pole, 16 - 3150A........................................................................................................18.44 3 pole, 30 - 800A..........................................................................................................18.53 4 pole, 16 - 3150A........................................................................................................18.47 6 Pole, mechanically interlocked, 30 - 800A.................................................................18.55 6 pole, 16 - 1200A........................................................................................................18.48 Description....................................................................................................................18.37 General information, fusible, 30 - 800A........................................................................18.43 General information, non-fusible, 16 - 3150A...............................................................18.42 Mechanically interlocked, 6 pole, 30 - 800A.................................................................18.55 eOT Enclosed switches................................................................................................18.38 eOT Enclosed switches, non-fusible, fusible & lockable..............................................18.41 Accessories Auxiliary contacts...............................................................................................18.52, 18.56 Miscellaneous accessories................................................................................18.52, 18.56 Dimensions eOT16 - eOT45U...........................................................................................................18.39 eOT63_..........................................................................................................................18.40 Technical data........................................................18.57 - 18.74 Auxiliary contact timing diagrams, OS200 - OES800...................................................18.70 Auxiliary contact timing diagrams, OS30_ - OS100.....................................................18.69 Auxiliary contact timing diagrams, OT16 - OT100........................................................18.67 Auxiliary contact timing diagrams, OT160 - OETL-NF3150.........................................18.68 Definitions.....................................................................................................................18.74 IEC Environmental ratings.............................................................................................18.73 NEMA Environmental ratings........................................................................................18.72 OS30AF_12 - OES800L3, IEC...........................................................................18.65, 18.66 OS30AF_12 - OES800L3, UL & CSA............................................................................18.64 OT16F3 - OT160E3, IEC....................................................................................18.60, 18.62 OT16F3 - OT160E3, UL & CSA.....................................................................................18.58 OT200U03 - OETL-NF3150, IEC........................................................................18.61, 18.63 OT200U03 - OETL-NF3150, UL & CSA........................................................................18.59 Other configuration descriptions..................................................................................18.71 Selecting switches per NEC.........................................................................................18.57 Use of UL98 & UL508 disconnects...............................................................................18.57 Dimensions (Non-Fusible & Fusible)......................18.75 - 18.98 16A - 3150A, 2, 3 & 4 Pole............................................................................................18.97 30 - 800A, 2, 3 & 4 Pole................................................................................................18.96 Conversion mechanisms, 125 - 200A...........................................................................18.91 Conversion mechanisms, 16 - 100A.............................................................................18.90 Conversion mechanisms, 400 - 1200A.........................................................................18.92 Conversion mechanisms, 400 - 3150A.........................................................................18.93 Handles..............................................................................................................18.94, 18.95 OES800L3..........................................................................................................18.87, 18.89 OETL-NF1200 - OETL - NF1600...................................................................................18.82 OETL-NF2000 - OETL-NF3150.....................................................................................18.83 OS100J03 - OS200J03.................................................................................................18.85 OS30AF_12 - OS60J_12...............................................................................................18.84 OS400J03 - OS600J03.................................................................................................18.86 OT16 - OT100F3C, Double throw.................................................................................18.78 OT160E3 & OT160ET3..................................................................................................18.79 OT16F3 - OT100F3.......................................................................................................18.75 OT16F6 - OT100F6, 6 pole...........................................................................................18.77 OT16FT3 - OT100FT3, Door mounted..........................................................................18.76 OT200_ - OT400_..........................................................................................................18.80 OT600U03 - OETL-NF800A..........................................................................................18.81 Terminal lugs.................................................................................................................18.88 18.A 1SXU000023C0202 18 ct ne s n o he sc Di witc s Notes 18 18.B 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Disconnect switches Non-fusible Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Non-fusible disconnect 16A - 3150A, 600V Di s s co switches No witc nne n- he ct fus s ibl e ABB SwitchLine includes 16 different amperage sizes from 16A to 3150A. The basic construction provides flexibility, safety, and high performance in an extremely compact size. ABB SwitchLine is a perfect choice for all switching applications from industrial motor control to construction safety switches. International acceptance UL listed, CSA approved, IEC rated, CE marked, and most other international standards. UL98 (CSA 22.2 No.4) -- UL File # E101914, CSA File #LR58077 For OT30, OT60, OT100, OT125, OT200, OT400, OT600, OETL-NF800 - OETL-NF2000 switches, OH_ pistol grip handles Suitable for use as motor disconnects or industrial control panel disconnects on service entrance equipment, panelboards, switchboards, industrial control equipment, motor control centers, etc. and are horsepower rated and ampere rated. UL508 (CSA 22.2 No. 14) -- UL File # E63822, CSA File #LR58247 For OT16 - OT80 switches, OH_ selector handles Suitable for use in equipment or machinery as motor controllers & motor disconnects and are horsepower and ampere rated. IEC Tested in accordance to IEC 947-1 and 3, IEC 664, IEC 269, and IEC 204 CE Compliance with the European Machine Directive IEC 204 (EN 60204) 18.1 1SXU000023C0202 18 ct ne s n o he e l sc Di witc usib s -f n No General information Selection guide OT16F3 - OT160E3 OT16F3 OT25F3 OT40F3 Catalog number 3 pole A OT63F3 OT16F3 OT25F3 OT80F3 OT30F3 OT60F3 OT40F3 OT63F3 OT80F3 OT30F3 OT100F3 OT60F3 OT100F3 16 25 40 60 80 30 60 100 N/A UL508 UL508 N/A UL508 UL508 N/A UL508 UL508 N/A UL508 UL508 N/A UL508 UL508 N/A UL98 UL98 N/A UL98 UL98 N/A UL98 UL98 600 600 600 600 600 600 600 600 5 10 10 7.5 15 20 10 20 25 15 30 30 20 40 40 10 20 30 20 40 40 30 50 50 1 2 1.5 3 2 5 2 5 2 5 2 5 3 7.5 5 15 Technical ratings - IEC2 Rated insulation and operational voltage. AC20 and DC20 V 750 750 750 750 750 750 750 750 Rated thermal current, Ith AC 20/DC 20 open AC 20/DC 20 enclosed A A 25 25 32 32 40 40 63 63 80 80 40 40 63 63 115 115 A A 16 16 25 25 32 32 63 63 80 80 40 40 63 63 100 100 Rated operational power AC23 400/415V kW 690V kW 7.5 7.5 9 9 11 11 22 15 37 18.5 15 15 18.5 15 37 37 General purpose amp rating Approvals 1 2 pole 3 pole 4 pole Technical ratings - UL,CSA 2 Max operating voltage V Max horsepower rating Three phase 240V HP 480V HP 600V HP Single phase 120V 240V AC 21A HP HP 500V 690V Physical characteristics Weight 3 3 pole lb 0.24 0.24 0.24 0.59 0.59 0.79 0.79 0.79 Dimension 3 pole H in W in D in 2.68 1.38 2.20 2.68 1.38 2.20 2.68 1.38 2.20 3.60 2.07 2.85 3.60 2.07 2.85 3.94 2.76 2.95 3.94 2.76 2.95 3.94 2.76 2.95 Integral Integral Integral Integral Integral Integral Integral Integral * * * * * * * * * * * * * * * * 6mm .24" x .24" 6mm .24" x .24" 6mm .24" x .24" 6mm .24" x .24" 6mm .24" x .24" 6mm .24" x .24" 6mm .24" x .24" 6mm .24" x .24" * * * * * * * * * * * * * * * * * * * * * * * * * * -- -- -- Recommended pistol handle length Maximum recommended shaft length 45 - 65mm 290mm 45 - 65mm 290mm 45 - 65mm 290mm 45 - 65mm 290mm 45 - 65mm 290mm 45 - 65mm 290mm 45 - 65mm 290mm 45 - 65mm 290mm Conversion kits 6 pole Transfer Bypass Mechanical interlock * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Electrical interlock -- -- -- -- -- -- -- -- Accessories Terminal lug kit Terminal shroud Auxiliary contact Shaft/handle diameter UL/NEMA type 18 Handle Type 1, 3R, 12 Type 1, 3R, 4, 4X, 12 Handle type Selector Pistol * = Available -- = Not available * * * 1 UL listed switches are also CSA approved. 2 For complete technical information please see page 18.38 - 18.70. 3 Switch only. 18.2 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage General information Selection guide OT200 - OT600 & OETL-NF800A - OETL-NF3150 OT200U03 OT400U03 Catalog number OETLNF1200SW OETL-NF1600SW OETL-NF2000SW OETL-NF3150SW OT400U03 OT600U03 OETL-NF800A OETL-NF1200 OETL-NF1600 OETL-NF2000 400 600 800 1200 1600 2000 3150 N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC IEC UL98 & IEC UL98 & IEC IEC UL98 & IEC UL98 & IEC IEC UL98 & IEC UL98 & IEC IEC IEC IEC IEC Technical ratings - UL,CSA 2 Max operating voltage V 600 600 600 600 600 600 480 600 Max horsepower rating Three phase 240V 480V 600V HP HP HP 75 150 200 125 250 350 200 450 500 250 500 600 -- -- -- -- -- -- -- -- -- -- -- -- Single phase 120V 240V HP HP -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Technical ratings - IEC 2 Rated insulation and operational voltage. AC20 and DC20 V 1000 1000 1000 1000 1000 1000 1000 1000 Rated thermal current, Ith AC 20/DC 20 open AC 20/DC 20 enclosed A A 250 250 400 400 800 800 1250 1250 1600 1600 2500 2300 2500 2300 3150 2600 AC 21A 500V 690V A A 250 250 400 400 800 800 1250 1250 1600 1600 25004 25004 25004 25004 31504 31504 Rated operational power AC23 400/415V kW 690V kW 132 240 220 355 400 800 400 -- 400 -- 400 -- 400 -- 400 -- A OT200U03 OETL-NF800ASW 200 General purpose amp rating 3 pole OT600U03 Di s s co No witc nne n- he ct fus s ibl e OETL-NF3150 Approvals 1 2 pole 3 pole 4 pole Physical characteristics Weight 3 3 pole lb 2.9 5.7 11.4 35.9 38.55 127.7 127.7 127.7 H in W in D in 6.69 6.67 3.30 8.66 8.7 3.35 10 10.64 5.56 19.09 14.29 4.92 19.09 14.29 4.92 25.04 18.43 10.67 25.04 18.43 10.67 25.04 18.43 10.67 Terminal lug kit OZXA-200 OZXA-400 OZXA-800 OZXA-30 OZXA-28 OZXA-28 OZXA-28/2 OZXA-28/2 Terminal shroud * * * * * * * * -- -- -- Auxiliary contact * * * * * Shaft/handle diameter 6mm .24" x .24" 12mm .47" x .47" 12mm .47" x .47" 12mm .47" x .47" 12mm .47" x .47" 12mm .47" x .47" 12mm .47" x .47" 12mm .47" x .47" Handle UL/NEMA type Type 1, 3R, 12 Type 1, 3R, 4, 4X, 12 * * * * * * * * * * * * * * * * Handle type Selector Pistol -- -- -- -- -- -- -- -- Recommended pistol handle length Maximum recommended shaft length 65 - 80mm 290mm 125 - 175mm 595mm 125 - 175mm 595mm 125 - 175mm 595mm 125 - 175mm 595mm 125 - 175mm 595mm 125 - 175mm 595mm 125 - 175mm 595mm * * * * * * * * * * * * * * * * * * * * * * * * * -- -- -- -- -- -- -- -- -- Dimension 3 pole Accessories * Conversion kits 6 pole Transfer Bypass Mechanical interlock Electrical interlock * * * * * * * * * * * * * S = Standard feature * = Available -- = Not available 1 2 3 4 UL listed switches are also CSA approved. For complete technical information please see page 18.38 - 18.70. Switch only IEC 947-3 Utilization Category B, Infrequent operation Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.3 1SXU000023C0202 18 ct ne s n o he e l sc Di witc usib s -f n No Selection information Standard part number designation 1 Non-Fusible OT Switches (16 to 125A) OT 16 F 3 C Amperage 16 = 16 amps* 25 = 25 amps* 40 = 40 amps* Number of Poles 3 = 3 poles 63 = 60 amps* 80 = 80 amps* 30 = 30 amps 60 = 60 amps 100 = 100 amps 160 = 125 amps 4 = 4 poles 6 = 6 poles Special Configuration C = Double throw switch * UL508 listed switches. OT30_, OT60_, OT100_, and OT160_ are cUL98 listed Non-Fusible OT Switches (200A and above) OT 200 U 03 C Amperage 200 = 200 amps 400 = 400 amps 600 = 600 amps Number of Poles & Placement of Mechanism 02 = 2 poles to right of mechanism 03 = 3 poles to right of mechanism 30 = 3 poles to left of mechanism 12 = 1 pole to left, 2 poles to right of mechanism 04 = 4 poles to right of mechanism 40 = 4 poles to left of mechanism 22 = 2 poles to left, 2 poles to right of mechanism 13 = 1 pole to left, 3 poles to right of mechanism Special Configuration C = Double throw switch All OT200_, 400_, and 600_ switches are cUL98 listed. Selector Handles OHB S 1 P H Handle Color B = black Y = Red/Yellow Physical Size Connection to Switch A = external shaft Protection Class H=1 P = snap on R = screw J= 1, 3R, 12 Pistol Handles O H B 65 J 6 E011 Handle Color B = Black Y = Red/Yellow Handle Length 18 65 = 65mm 80 = 80mm M = Stainless Steel 125 = 125mm 145 = 145m 175 = 175mm 275 = 275mm Environmental Rating J = 1, 3R, 12 L = 1, 3R, 12, 4, 4X Shaft Diameter 6 = 6mm 12 = 12mm Special Configuration E011 = 3 position double throw handle 1 Part designation keys are provided for reference only. Not all variations or configurations are available. 18.4 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s s co No witc nne n- he ct fus s ibl e Base & DIN rail mounted 1 16A - 3150A For a complete assembly, please select one of each: 1 switch (pg. 18.5) 1 handle (pg. 18.6) 1 shaft (pg. 18.7) 1 terminal lug kit (pg. 18.9) (Lug kits only necessary on switches 200A and above) OT200U03 + 2 Pole 3 Pole UL only UL general purpose amp rating IEC AC21 amp rating UL 508 20 30 40 60 80 16 25 40 63 80 -- -- -- -- -- -- -- -- -- -- OT16F3 OT25F3 OT40F3 OT63F3 OT80F3 30 60 100 40 63 115 -- -- -- -- -- -- 200 -;250 OT200U02 400 630 600 800 800 1200 1600 2000 - 1250 1600 2500 4 2500 4 3150 4 Catalog number OXP6X210 List price OHB80J6 4 Pole 2 OZXA-200 6 Pole 3 List price Catalog number List price $ 66 72 76 100 120 -- -- -- -- -- -- -- -- -- -- OT16F6 OT25F6 OT40F6 OT63F6 OT80F6 $ 192 204 212 260 300 OT30F3 OT60F3 OT100F3 150 175 200 -- -- -- -- -- -- OT30F6 OT60F6 OT100F6 $ 560 OT200U03 OT200U30 OT200U12 620 620 620 OT200U04 OT200U40 OT200U22 $ 780 780 780 -- -- -- -- -- -- OT400U02 1,280 OT400U03 OT400U30 OT400U12 1,420 1,420 1,420 OT400U04 OT400U40 OT400U22 1,800 1,800 1,800 -- -- -- -- -- -- OT600U02 2,000 2,800 2,800 2,800 5,200 8,600 20,500 21,500 23,600 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- OETL-NF800A2SW OETL-NF12002SW OETL-NF16002SW OETL-NF20002SW OETL-NF31502SW 2,600 6,200 14,800 15,500 17,000 OT600U03 OT600U30 OT600U12 OETL-NF800ASW OETL-NF1200SW OETL-NF1600SW OETL-NF2000SW OETL-NF3150SW List price + Catalog number UL 98 Catalog number + 2,200 2,200 2,200 4,200 6,800 16,400 17,200 18,900 OT600U04 OT600U40 OT600U22 OETL-NF800A4SW OETL-NF12004SW OETL-NF16004SW OETL-NF20004SW OETL-NF31504SW 360 410 460 Bulk packed 3 Pole, 600V Switches UL only UL general IEC AC21 purpose amp rating amp rating Bulk pack Quantity Catalog number UL508 20 30 40 60 80 16 25 40 63 80 50 50 50 50 50 OT16F3/B OT25F3/B OT40F3/B OT63F3/B OT80F3/B UL98 30 60 100 40 63 115 25 25 25 OT30F3/B OT60F3/B OT100F3/B 1 2 3 4 List price Consult factory Consult factory 18 Above 125A, base mount with screws only. A snap on fourth pole may be added on 16-125A switches. Reference pg. 18.9. For a 6 or 8 pole switch 200 amp and above, a conversion mechanism accessory kit can be used with two 3 or 4 pole switches. Reference pg. 18.10. Vertical busbar provided as standard on OETL-NF1600-OETL-NF3150 switches. For alternate back or edgewise mounting busbar, reference pg. 18.10. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule H1 [D1]: NF 16A - 100A Discount schedule H2 [D2]: NF 125A - 800A Discount schedule H3 [D3]: NF 1200A - 3150A 18.5 1SXU000023C0202 ct ne s n o he e l sc Di witc usib s -f n No Standard handles & shafts 12 OHBS2AJ1 OHB__J6 OHY__J6 YASDA-8 OHM125L12 Recommended handles & shafts Switch Shaft diameter Recommended standard pistol handle length Maximum recommended shaft length OT16 - 100 OT160 - 200 OT400 - 600 OETL-NF800 - 3150 6x6 mm - .24 x .24" 6x6 mm - .24 x .24" 12x12 mm - .47 x .47" 12x12 mm - .47 x .47" 45 - 65 mm 65 - 80 mm 125 - 175 mm 125 - 175 mm 290 mm 290 mm 595 mm 595 mm Selector handles -- for use with .24 x .24" (6mm) OXS6X_shafts UL/NEMA Type IEC type Color Marking Defeatable 1 IP54 Black O/I & Off/On -- 1, 3R, 12 IP65 Black O/I & Off/On -- Yes Padlockable Weight (lbs) Catalog number List price -- Yes Yes Yes 0.09 0.12 0.16 0.16 OHBS1AH1 3 OHBS3AH1 3 OHBS2AJ1 OHBS2AJ $ 22 24 28 30 Catalog number List price Pistol handles -- for use with .24 x .24" (6mm) OXP6X_ shafts UL/NEMA Type IEC type Color Marking 1, 3R, 12 IP65 Black O/I & Off/On 1, 3R, 12, 4, 4X IP66 Black O/I & Off/On 1, 3R, 12, 4, 4X 1, 3R, 12 1, 3R, 12, 4, 4X IP66 IP65 IP66 316L Stainless steel Black w/ 316 stainless hasp Black w/ 316 stainless hasp O/I & Off/On O/I & Off/On O/I & Off/On Length in/mm Defeatable Padlockable Weight (lbs) 2.6/65 3.1/80 2.6/65 3.1/80 2.6/65 2.6/65 2.6/65 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.29 0.30 0.29 0.30 1.60 0.31 0.31 Length in/mm Defeatable Padlockable Weight (lbs) Catalog number 4.9/125 5.7/145 6.9/175 4.9/125 5.7/145 6.9/175 8.7/220 4.9/125 6.9/175 275 4.9/125 6.9/175 4.9/125 6.9/175 Yes Yes Yes Yes Yes Yes -Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.39 0.39 0.41 0.39 0.39 0.41 1.50 1.70 1.80 2.10 0.44 0.46 0.44 0.46 OHB125J12 OHB145J12 OHB175J12 OHB125L12 OHB145L12 OHB175L12 YASDA-8 OHM125L12 OHM175L12 OHM275L12 OHB125J12EH OHB175J12EH OHB125L12EH OHB175L12EH OHB65J6 OHB80J6 OHB65L6 OHB80L6 OHM65L6 OHB65J6EH OHB65L6EH $ 80 90 120 130 750 250 290 Pistol handles -- for use with .47 x .47" (12mm) OXP12X_ shafts UL/NEMA Type IEC type Color Marking 1, 3R, 12 IP65 Black O/I & Off/On 1, 3R, 12, 4, 4X IP66 Black O/I & Off/On 1, 3R, 12, 4, 4X IP66 Metal Off/On 1, 3R, 12, 4, 4X IP66 316L Stainless steel O/I & Off/On 1, 3R, 12 IP65 Black w/ 316 stainless hasp O/I & Off/On 1, 3R, 12, 4, 4X IP66 Black w/ 316 stainless hasp O/I & Off/On 18 List price $ 90 90 100 130 130 140 190 900 1,100 1,200 280 330 330 390 Direct mount handle Description For use on Mounts directly on switch. No shaft necessary OT16-40 OT63-80 OT30-100 Black Yes 0.05 OT160 Black Yes 0.05 OHB13 OT200 OT400 OT600 OT400-OETL NF800 OETL-NF1200-OETL-NF3150 Black Black Black Metal Metal Yes Yes Yes No No 0.22 0.44 0.66 0.78 0.80 OTV250EK OTV400EK OTV800EK YASDA-33 YASDA-34 Mounts directly on switch. No shaft necessary Up to 3 padlocks in OFF-position, includes shaft and mechanism Mounts on shaft 1 2 3 4 Color Padlockable Weight Catalog number OHBS12 4 OHBS2 4 List price $ 17 22 105 130 155 155 180 Red/Yellow handles are available by substituting the OHB prefix with OHY. All handles are plastic unless otherwise noted as metal or stainless steel. Not recommended for use on OT30-100. Suitable for 3 & 4 pole versions only. Not for use with 6 or 8 pole or double throw configurations. 18.6 1SXU000023C0202 Discount schedule H6 [DH]: Handles, shafts, accessories & lug kits Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s s co No witc nne n- he ct fus s ibl e Standard handles & shafts OX6X_ OXP12X_ OXS6X__ Shafts for use with selector handles - .24 x .24" (6x6 mm) Maximum Mounting Depth (inches) 1 Shaft length (in/mm) OT16F3, OT25F3, OT40F3 OT30F3, OT60F3, OT100F3 OT63F3, OT80F3 OH_1_ & OH_3_ OH_2_ OH_1_ & OH_3_ OH_2_ OH_2_ 5.0 5.8 6.4 6.7 8.7 11.5 14.6 4.3 5.1 5.8 6.1 8.1 10.8 14.0 5.6 6.4 7.0 7.4 9.4 12.1 15.3 5.0 5.8 6.4 6.8 8.7 11.5 14.7 5.0 5.8 6.4 6.8 8.7 9.9 14.6 3.3/85 4.1/105 4.7/120 5.1/130 7.1/180 9.8/250 13/330 Weight 0.07 0.07 0.08 0.08 0.11 0.13 0.17 Catalog number OXS6X85 OXS6X105 OXS6X120 OXS6X130 OXS6X180 OXS6X250 OXS6X330 List price $4 4 4 6 6 12 20 Shafts for use with pistol handles - .24 x .24" (6x6 mm) Maximum Mounting Depth (inches) Shaft length (in/mm) Weight OT16F3 - OT40F3 OT63F3-OT80F3 OT30F3-OT100F3 OT160E3 OT200 5.9 6.7 9.1 12.2 14.9 17.6 6.4 7.4 9.7 12.8 13.8 18.3 6.7 7.0 9.8 12.9 15.6 18.3 6.0 6.7 9.1 12.2 15.0 17.8 6.5 7.2 9.6 12.7 15.5 18.2 5.2/130 5.9/150 8.3/210 11.4/290 14.2/360 16.9/430 0.08 0.09 0.13 0.18 0.23 0.27 Catalog number OXP6X130 OXP6X150 OXP6X210 OXP6X290 OXP6X360 OXP6X430 List price $ 12 12 16 20 24 28 Shafts for use with pistol handles - .47 x .47" (12x12 mm) Maximum Mounting Depth (inches) Shaft length (in/mm) 11.0/280 12.8/325 15.6/395 18.3/465 21.1/535 OT400 OT600 OETL-NF800 -- OETL-NF1200 OETL-NF1600-OETL-NF3150 13.3 15.0 20.5 21.9 22.8 14.6 16.4 19.1 21.8 24.6 14.5 16.3 19.1 21.9 24.6 -- 20.9 23.6 26.3 29.1 Weight Catalog number 0.77 0.90 1.10 1.32 1.54 OXP12X280 OXP12X325 OXP12X395 OXP12X465 OXP12X535 List price $ 36 40 44 48 52 1 Mounting depth is distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule H6 [DH]: Handles, shafts, accessories & lug kits 18.7 1SXU000023C0202 18 ct ne s n o he e l sc Di witc usib s -f n No Standard non-fusible accessories Base and DIN rail mounted switches (N)7 L4 3 OT16E (N)8 T4 I ON N N N PE N N N PE O OFF Auxiliary contacts -- snap-on mounting 1 Description For Use On Weight AC Thermal amp rating AC rated voltage 1 N.O. OT16-100, OT200-600 OT16-100 OT200-600 OT16-160 0.07 0.07 0.07 0.07 10 10 10 10 600 600 600 600 OT160 0.06 - - OAZX1 20 OT200-600 0.1 - - OEA28 50 1 N.C. 1 N.O. & 1 N.C. Mounting Base - required for OA2G11 on OT160 Module for auxiliary contacts Catalog number List price $ 20 20 20 40 OA1G10 OA1G01 OA3G01 OA2G11 OEA28 Auxiliary contacts -- top mounting Description For Use On Weight AC Thermal amp rating AC rated voltage Catalog number List price 1 N.O. 1 N.C. OEZNP1 OT160 OEZNP1 & OT160 0.07 0.07 0.07 0.07 10 10 10 10 600 600 600 600 OBEA-10 OBEA-01 OBEA-10AU OBEA-01AU $ 28 28 56 56 OBEA_ contacts used with OT160 0.06 - - OEZNP1 20 OT160 OT160 - - - OBEA-ZX10 OBEA-ZX01 32 32 For Use On Weight AC Thermal amp rating AC rated voltage Catalog number List price OETL-NF800 through OETL-NF3150 0.2 0.26 0.4 0.18 0.25 0.4 10 10 10 10 10 10 600 600 600 600 600 600 OZXK-1 OZXK-2 OZXK-3 OZXK-4 OZXK-5 OZXK-6 $ 100 170 340 100 170 340 1 N.O. gold plated 2 OA1G__ Mounting Base - required for OBEA_ 1 pkg. of 10 blank numbering labels for OBEA-__ 3 Auxiliary contacts -- front mounting 4 Description 1 N.O. + 1 N.C. 2 N.O. + 2 N.C. 4 N.O. + 4 N.C. 2 N.O. 4 N.O. 8 N.O. OEZNP1 18 Mounting & installation considerations OT16-100 OT160 OAZX1 OA2G11 OT200-600 1 2 3 4 18.8 1SXU000023C0202 OA1G10 (1 N.O.) mounts on right side of switch only OA1G01 (1 N.C.) mounts on left side of switch only OA2G11 (1 N.O. & 1 N.C.) mounts on left of right side of switch Maximum two contacts on each side of switch Accepts four contacts maximum Mounting base always required Maximum two side mounted contacts on each side of switch. One mounting base required for each side Maximum 8 auxiliary contact blocks with the OEA28 module Maximum 4 auxiliary contact blocks mounting under the mechanisms UL file #E83510 Type _AU for low energy applications. The contacts are gold plated, AC & DC ratings - Maximum: A600 & P600; Minimum: 12V, 1mA; 5V; 2mA Numbering stickers required if several OBEA contacts are used in the same installation. UL File #E5707 Discount schedule H6 [DH]: Handles, shafts, accessories & lug kits Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s s co No witc nne n- he ct fus s ibl e Standard non-fusible accessories Base & DIN rail mounted switches Additional poles 1 Power poles - Only one power pole per switch: mounts on left or right side of switch. (OTPS40FPN1 mounts to left side only.) Weight AC Thermal amp rating OT16-OT40 OT30-OT60 OT63-OT80 OT100 0.07 0.13 0.13 0.31 40 60 80 100 OT160 0.66 OT16-OT40 OT30-OT60 OT63-OT80 OT100 0.07 0.13 0.13 0.31 Description Fourth Pole Late-break/ early-make OTP_40FP For use on AC rated voltage Catalog number List price OTPS40FPN1 OTPS60FP OTPS80FP OTPS125FP $ 36 46 44 54 125 OTPS160EP 100 40 60 80 100 OTPL40FP OTPL60FP OTPL80FP OTPL125FP 36 46 44 54 600 600 Terminal poles - Switch accepts one terminal pole per side: mounts on left or right side of switch Weight AC Thermal amp rating OT16-OT40 OT63-OT80 OT30-OT100 0.07 0.13 0.31 40 80 100 OT160 OT16-OT40 OT30-OT60 OT63-OT80 OT100 0.66 0.07 0.13 0.13 0.31 125 40 60 80 60 OT16-OT40 OT30-OT60 OT63-OT80 OT100 0.07 0.13 0.13 0.31 40 60 80 100 OT160 0.66 125 Description Solid neutral OTP_80FP OTP_125FP Detachable Neutral Ground Terminal OZXA-400 For use on AC rated voltage 600 600 600 Catalog number List price OTPN40FP OTPN80FP OTPN125FP $ 20 36 50 OTPN160EP OTPD40FP OTPD60FP OTPD80FP OTPD125FP 100 28 38 36 50 OTPE40FP OTPE60FP OTPE80FP OTPE125FP 20 38 36 50 OTPE160EP 100 OZXA-27 Terminal lugs 2 For Use On Wire Type Lugs/Kit OT200 #4 - 300 kcmil #4 - 300 kcmil (6) 14-6 AWG Cu/Al 6 3 3 0.50 0.25 0.25 OZXA-200 OZXA-200/3 OZXA-206T $ 80 40 200 OT400 #2 - 600 kcmil #2 - 600 kcmil (2) #4 - 300 kcmil (6) #14 - 6 AWG Cu/Al 6 3 6 3 0.50 0.25 0.50 0.50 OZXA-400 OZXA-400/3P OZXA-402 OZXA-406 190 100 210 270 OT600 (2) #2 - 600 kcmil (2) #2 - 600 kcmil Cu/Al 6 3 0.50 0.50 OZXA-800 OZXA-800/3 360 180 (2) #2 - 600 kcmil (2) #2 - 600 cmil (8) 2/0 + (2) #2 - 600 kcmil 3 Cu/Al 6 3 3 6.90 3.45 6.90 OZXA-30 OZXA-30/3P OZXA-32 740 370 600 6 3 3 12 10.44 5.22 10.44 20.88 OZXA-30 OZXA-32 OETL-NF800A OETL-NF1200-1600 OETL-NF2000-3150 OZXA-175/400 Wire Size (4) #2 - 600 kcmil (4) #2 - 600 kcmil (8) 2/0 + (2) #2 - 600 kcmil 3 (8) #2 - 600 kcmil Terminal shrouds OTS250G1L/3 OTS250G1S/3 Cu/Al Cu/Al Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage OZXA-28 OZXA-28/3 OZXA-32 OZXA-28/2 Catalog number List price 1,000 500 600 2,000 For Use On Weight 3 pole includes one shroud for line or load side OT16-OT40 OT63-OT80 OT30-OT100 0.02 0.02 0.02 OTS40T3 OTS80T3 OTS125T3 $8 20 20 4th pole includes one shroud for line or load side OTPS40FPN1 OTPS80FP OTPS125FP 0.03 0.03 0.03 OTS40T1 OTS80T1 OTS125T1 4 6 10 List price 3 pole long type shrouds 0.2 OTS250G1L/3 50 3 pole short type shrouds 0.13 OTS250G1S/3 50 0.26 OTS250G1L/4 65 3.18 OTS250G1S/4 4 pole long type shrouds OTS40T1 OTS80T1 OTS125T1 Catalog number Description OT200 4 pole short type shrouds OTS40T3 OTS80T3 OTS125T3 Weight (lbs) 65 3 pole includes one shroud for line or load side 4 OT400 OT600 0.33 0.33 OTS403 OTS603 120 190 3 pole includes one shroud for line or load side 4 OETL-NF800A OETL-NF1200 0.88 1.2 OETL-ZX800A OETL-ZX119 180 220 1 2 3 4 Switches accept only one power pole or one terminal pole per side. Only one power pole per switch. Lugs are integral to the switch for 16-125A. No separate lug kit accessory is required. A load side distribution lug eliminates the need to purchase, install and wire a separate distribution block. For 4 pole shrouds, please consult factory. Discount schedule H6 [DH]: Handles, shafts, accessories & lug kits 18.9 1SXU000023C0202 18 ct ne s n o he e l sc Di witc usib s -f n No Standard non-fusible accessories Base and DIN rail mounted switches Conversion Mechanisms Mechanism Type For use on 6 or 8 pole mechanisms OTZW8 Double throw mechanisms N Mechanical interlock mechanisms OTZW6 Catalog number List price - OTZW8 OETL-ZK19 OESA-ZW2 OETL-ZW9 $ 60 40 220 260 OT16 - 160 2.20 1, 3R, 12 1, 3R, 12, 4, 4X OESA-ZW1 OESA-ZW1X 300 340 OT200 2.20 1, 3R, 12 1, 3R, 12, 4, 4X OTZW25 OTZW25X 790 840 10.10 1, 3R, 12, 4, 4X OETL-ZW12 560 1.54 1, 3R, 12 1, 3R, 12, 4, 4X OTZW17 OTZW17X 340 380 OT16-OT100 IO UL/Nema Type 0.33 1.52 1.52 2.42 OT400 - OETL-NF1200 Bypass mechanisms Weight OT16-100 OT160 OT200 OT400 - OETL-NF1200 OT200 7.28 1, 3R, 12 OTZW26 950 OT400 - OETL-NF1200 8.81 1, 3R, 12, 4, 4X OETL-ZW13 560 OT16-OT100 OT160-200 OT400 - OETL-NF800 OETL-NF1200 - OETL-NF3150 0.33 0.55 1.26 2.64 - OTZW24 OTZW10 OETL-ZW3 OETL-ZW15 80 100 140 160 Miscellaneous Accessories & Replacement Parts Shaft Accessories OTZW17 Accessory Type For Use On Weight Catalog number List price 6mm shafts 0.20 OETL-ZK19 $ 40 Shaft Extension Joins two shafts together for applications where Coupler extended length is required 6mm shafts 12mm shafts 0.26 0.26 OESA-ZX167 OETL-ZX95 56 100 Fits all pistol grip handles, mounts on the inside of the enclosure door with provided hardware pistol handles - Shaft Adapter Shaft Guide OETL-ZW24 Description Adapts one end of a 6mm shaft to 12mm (use with shaft extension coupler) OHZX10 12 Busbar Connections Accessory Type Description Busbar Connections Vertical, back or edgewise mounting 1 For Use On Weight OETL-NF1600 - 3150 46.2 31.0 Catalog number OETL-ZX115 OETL-ZX114 List price $ 3,916 2,820 Locking Accessories Accessory Type Description For Kirk Key, Castell, Low & Fletcher and Cam Attachment Ronis interlock. For adapting to the interlock system. The interlock is not included. OETL-ZT80_ Electrical Interlock 18 Closed circuit principle for interlocking the switch movement. When the coil circuit is dead, A-types cannot be operated to O-position and L-types cannot be operated to ON- or OFF-position. Coil voltages 110VAC, 220 VAC, 24VDC, 48VDC, 60VDC, 110VDC, 220VDC, P - 15W U = 0.7 - 1.1 Un (U = coil voltage, Un = nominal voltage) For Use On Weight Catalog number List price 12mm shafts 0.29 OETL-ZW5 $ 190 OETL-NF800 - 3150A 2.42 OETL-ZT80A OETL-ZT80L 1280 1220 = Coil Voltage Replacement Parts OETL-ZX115 Accessory Type Description Metal collar Replaces original black knob for locking shaft in place Set Screw Set screw for use with knob or collar For Use On Catalog number List price $ 13 OT16-200 OTZS2 OT16-100 FLSWM5X8AX 2 OT200 FLSWM5X6X 2 OETLZX114 CYBY68998 OTZS2 1 Vertical busbar is provided as standard on OETL-NF1600 through OETL-NF3150 switches. 18.10 1SXU000023C0202 Discount schedule H6 [DH]: Handles, shafts, accessories & lug kits Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s s co No witc nne n- he ct fus s ibl e Door mounted 1 16 - 100A For a complete assembly, please select one of each: 2 1 switch (pg. 18.11) 1 handle (pg. 18.11) OT63FT3 OHBS2RJ Bulk packs 3 Pole 3 UL only UL general purpose amp rating IEC AC21 amp rating UL508 20 30 40 60 80 16 25 40 63 80 30 60 100 40 63 115 UL98 Catalog number Bulk pack Catalog number List price List price Bulk pack quantity OT16FT3 OT25FT3 OT40FT3 OT63FT3 OT80FT3 $ 70 76 80 104 124 50 50 50 50 50 OT16FT3/B OT25FT3/B OT40FT3/B OT63FT3/B OT80FT3/B OT30FT3 OT60FT3 OT100FT3 154 179 204 25 25 25 OT30FT3/B OT60FT3/B OT100FT3/B Defeatable Padlockable Weight (lbs) Catalog number List price OHBS1PH OHBS3PH OHBS2PJ $ 22 24 28 OHBS1RH OHBS3RH OHBS2RJ $ 22 24 28 Consult factory Selector handles for door mounted switches UL/NEMA Type IEC Type Color Snap-on Mounting - for use on OT16FT3 - OT40FT3 -- 0.10 Yes 0.13 1, 3R, 12 IP65 Black -- Yes 0.17 Screw mounting - for use on OT16FT3 - OT100FT3. For OT30, OT60, and OT100 use OH_ _2_ only -- 0.11 1 1P54 Black -- Yes 0.14 1, 3R, 12 IP65 Black -- Yes 0.18 1 IP54 Black -- Pistol grip handle adapter 4 Description For use on Weight (lbs) Catalog number List price Adapter piece for pistol grip handle OT30-100 0.18 OHZX6 $ 20 Includes hardware and shaft for pistol grip handles. Pistol handle must be ordered separately (see pg. 18.6) 18 1 2 3 4 Door mounted switches do not provide door interlock Door mounted switches do not require shafts A snap on fourth pole may be added - please reference accessories pg. 18.8 The environmental rating of the pistol handle derates to NEMA 1 when used in conjunction with the OHZX6 adapter. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule: H1 [D1]: 16-100A Discount schedule: H6 [DH]: Handles, shafts, accessories & lug kits 18.11 1SXU000023C0202 ct ne s n o he e l sc Di witc usib s -f n No Standard non-fusible accessories Door mounted switches Auxiliary contacts 1 -- snap-on mounting Description For use on: Weight (lbs) AC thermal AC rated amp rating voltage 1 N.O. mounts on right hand 0.07 10 side of switch OT16 - OT100 1 N.C. mounts on left hand 0.07 10 side of switch Catalog number List price 600 OA1G10 $ 20 600 OA1G01 20 Max. two contacts on each side of switch. Power poles Switch accepts one terminal pole per side: mounts on left or right side of switch. (OTPS40FDN1 mounts to left side only.) OA1G__ Description For use on: Fourth pole Late-break/early-make Weight (lbs) AC thermal AC rated amp rating voltage Catalog number OT16, OT25, OT40 OT30-OT60 OT63, OT80 OT100 0.07 0.13 0.13 0.20 40 60 600 80 100 OTPS40FDN1 OTPS60FD OTPS80FD OTPS125FD OT16, OT25, OT40 OT63, OT80 OT100 0.07 0.13 0.20 40 80 600 100 OTPL40FD OTPL80FD OTPL125FD List price $ 36 46 44 54 36 44 54 Terminal poles Switch accepts one terminal pole per side: mounts on left or right side of switch OTP_40FD Description For use on: Solid neutral OTP_80FD 18 OT16, OT25, OT40 OT30-OT60 OT63, OT80 OT100 Weight (lbs) AC thermal AC rated amp rating voltage 0.07 0.13 0.13 0.20 40 60 600 80 100 Catalog number OTPN40FD OTPN60FD OTPN80FD OTPN125FD List price $ 20 38 36 50 Detachable neutral OT16, OT25, OT40 0.07 40 OTPD40FD OT30-OT60 0.13 60 600 OTPD60FD OT63, OT80 0.13 80 OTPD80FD 28 38 36 Ground terminal OT16, OT25, OT40 OT30-OT60 OT63, OT80 OT100 20 38 36 50 0.07 0.13 0.13 0.20 40 60 600 80 100 OTPE40FD OTPE60FD OTPE80FD OTPE125FD Terminal shrouds -- snap-on mounting for line or load side 3 Description For use on: OTS40T3 OTS80T3 OTS125T3 OTS40T1 OTS80T1 OTS125T1 Weight (lbs) Catalog number List price 3 pole includes one shroud for line or load side OT16, OT25, OT40 OT63, OT80 OT30, OT60, OT100 0.02 0.02 0.02 OTS40T3 $8 OTS80T3 20 OTS125T3 20 4th pole includes one shroud for line or load side OTP_40FD OTP_80FD OTP_125FD 0.02 0.02 0.02 OTS40T1 4 OTS80T1 6 OTS125T1 10 1 UL File # E83510 2 ABB switches are IP20 touchsafe as standard. Shrouds provide an extra degree of protection. 18.12 1SXU000023C0202 Discount schedule H6 [DH]: Handles, shafts, accessories & lug kits Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s s co No witc nne n- he ct fus s ibl e Special configurations Shaft operated flange 30A - 100A Switch Handle Shaft 30A -100A Flange operated -- non fusible switches (Shaft) - 3 pole UL general purpose amp rating Catalog number 30 60 100 OT100F3 OT30F3-F OT60F3-F OT100F3-F List price $ 500 590 690 Flange handles -- for use with OT30_, OT60_, OT100 UL/ NEMA type Marking Defeatable Padlockable Catalog number List price 1, 3R, 12 4, 4X OFF/ON OFF/ON Yes Yes Yes Yes DSFHN-HS12 DSFHN-HS4 $ 156 240 Shafts DSFHN-HS12 For use with: Maximum enclosure depth (inches) Catalog number List price OT30_ - OT100_ OT30_ - OT100_ 16 24 OTFS-16 OTFS-24 $ 25 30 Door hardware NEMA 12 Item DSFHS-12 Catalog number List price Safety door latch, 2 point, door less than 40" high KDH2R $ 200 Safety door latch, 2 point, door greater than 40" high KDH3R 225 Flange operated fusible and non-fusible disconnect switches ABB's solution for complying with the new NFPA79 requirements is Flange Operated Fusible and Non-fusible Disconnect Switches. New 2002 NFPA 79 changes requires main disconnecting means to be operable without the use of accessory tools or devices, independent of door position. This code also includes an interlocking provision to prevent the closing of disconnects while the enclosure door is open, unless an interlock is operated by a deliberate action. The flange operated disconnect switches are available as ridged shaft or flexible cable operated versions. The cable operated version allows you to install the disconnect switch anywhere in the enclosure depending on the length of the cable. Cables are available in lengths up to 84 inches. The designs are cost-effective NFPA 79 solutions offering quick and easy installation. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule H1 [D1]]: NF16A - 100A Discount schedule H2 [D2]: NF125A - 800A Discount schedule H6 [DH]: Handles, shafts, accessories and lug kits Discount schedule SH [SH]: Door hardware kits 18.13 1SXU000023C0202 18 ct ne s n o he e l sc Di witc usib s -f n No Switch Special configurations Cable operated flange 30A - 200A Handle Cable Lug kit (as required) Operating mechanism Non-fusible OT100F3 UL general purpose amp rating Catalog number List price 30 60 100 125 200 OT30F3 OT60F3 OT100F3 OT160E3 OT200U30 $ 150 175 200 420 620 Flange handles -- UL98; UL file #E101914 For use with: Environmental rating NEMA 1, 3R, 12 NEMA 4, 4X OT30 - 100F3, OT160E3, OT200U30 Catalog number OHF1C12 OHF1C4 List price $ 213 243 Flexible cables OHF1C12 Catalog number Cable length (inches) For use with: 36 48 60 72 84 OT30 - 100F3, OT160E3, OT200U30 OXC1L36 OXC1L48 OXC1L60 OXC1L72 OXC1L84 List price $ 114 146 160 175 204 Operating mechanisms Catalog number For use with: OT30 - 100F3 OT160E3 OT200U30 OXC1L36OXC1L84 Terminal lug kits For use with 18 OT200U30 Wire size #4 - 300 kcmil #4 - 300 kcmil (6) #4-6 AWG Wire type Cu/Al Cu/Al Cu/Al MKCS1 MKCS3 MKCS4 Description -- -- Distribution lug Lugs per kit 6 3 3 Catalog number OZXA-200 OZXA-200/3 OZXA-206S List price $ 135 162 171 List price $ 80 40 200 Door hardware -- NEMA 12 Item Safety door latch, 2 point, door less than 40" high Safety door latch, 3 point, door greater than 40" high 18.14 1SXU000023C0202 Discount schedule H2 [D2]: NF125A - 800A Discount schedule H6 [DH]: Handles, shafts, accessories and lug kits Discount schedule H3 [D3]: NF1200A - 3150A Discount schedule SH [SH]: Door hardware kits Catalog number KDH2R KDH3R List price $ 200 200 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s s co No witc nne n- he ct fus s ibl e Special configurations Double throw switches 16A - 600A For a complete assembly, please select one of each: 1 switch (pg. 18.15) 1 handle (pg. 18.16) 1 shaft (pg. 18.16) 1 terminal lug kit (pg. 18.15) 1 bridging bar (pg. 18.15) (Lug kits only necessary on switches 200A and above) OHY__J6E011 OT200U04C 3 Pole UL only UL general purpose amp rating UL98 Catalog number Bridging bars 4 Pole 1 List price Catalog number List price $ 258 270 288 328 368 -- -- -- -- -- -- -- -- -- -- 428 478 514 -- -- -- -- -- -- 20 30 40 60 80 16 25 40 63 80 OT16F3C OT25F3C OT40F3C OT63F3C OT80F3C 30 60 100 40 63 115 OT30F3C OT60F3C OT100F3C 200 250 OT200U03C OT200U30C 1,850 1,850 OT200U04C OT200U40C $ 2,100 2,100 400 630 OT400U03C OT400U30C 3,250 3,250 OT400U04C OT400U40C 3,550 3,550 600 800 OT600U03C OT600U30C 4,800 4,800 OT600U04C OT600U40C 5,500 5,500 UL508 OT63F3C IEC AC21 amp rating Lug kit (as required) OXS6X__ Bridging busbar kits -- required for OT200_C through OT600_C 2 Description OHBS2AJE011 3 Pole Kit 4 Pole kit For Use On: Catalog number OT200_C OT400_C OT600_C OT200_C OT400_C OT600_C OTZC13 OTZC23 OTZC33 OTZC14 OTZC24 OTZC34 List price $ 80 160 240 110 220 330 Bridging bars are required on 200-600A double throw switches to operate as standard double throw switches. Otherwise, they will operate as two mechanically interlocked switches. OHB__J6E011 18 OHY__J6E011 OXS6X__ 1 A snap on power pole may be added to build a 4 pole 16-100A double throw switch. Reference pg. 18.9. 2 For 16-100A double throw switches, jumpers are not provided. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule HT1 [D6]: 16-100A Double throw switches Discount schedule HT1 [D6]: 200-600A Double throw switches Discount schedule H7 [DR]: Handles, shafts, accessories & lug kits 18.15 1SXU000023C0202 ct ne s n o he e l sc Di witc usib s -f n No Special configurations Handles & shafts for double throw switches Recommended handles & shafts Switch Shaft diameter Recommended standard pistol handle length Maximum recommended shaft length OT16 - 100 OT200 OT400 - 600 6x6 mm - .24 x .24" 6x6 mm - .24 x .24" 12x12 mm - .47 x .47" 45 - 65 mm 65 - 80 mm 125 - 175 mm 290 mm 290 mm 595 mm Shafts -- for use with selector handles .24 x .24" (6x6mm) Mounting depth (inches) Shaft length (in/mm) OH_1_ & OH_3_ OH_2_ OH_1_ & OH_3_ OH_2_ OT30F3, OT60F3, OT100F3 OH_2_ 5.0 5.8 6.4 6.7 8.7 11.5 14.6 4.3 5.1 5.8 6.1 8.1 10.8 14.0 5.6 6.4 7.0 7.4 9.4 12.1 15.3 5.0 5.8 6.4 6.8 8.7 11.5 14.7 5.0 5.8 6.4 6.8 8.7 9.9 14.6 OT16F3, OT25F3, OT40F3 3.3 / 85 4.1 / 105 4.7 / 120 5.1 / 130 7.1 / 180 9.8 / 250 13 / 330 OT63F3, OT80F3 Weight (Lbs.) Catalog number List price 0.07 0.07 0.08 0.08 0.11 0.13 0.17 OXS6X85 OXS6X105 OXS6X120 OXS6X130 OXS6X180 OXS6X250 OXS6X330 $4 4 4 6 6 12 20 Weight (Lbs.) Catalog number List price Shafts -- for use with pistol handles .24 x .24" (6x6mm) Maximum mounting depth (inches) Shaft length (in/mm) OT16F3 - OT40F3 OT63F3-OT80F3 OT30F3-OT100F3 OT160E3 OT200 5.9 6.7 9.1 12.2 14.9 17.6 6.4 7.4 9.7 12.8 13.8 18.3 6.7 7.0 9.8 12.9 15.6 18.3 6.0 6.7 9.1 12.2 15.0 17.8 6.5 7.2 9.6 12.7 15.5 18.2 5.2 / 130 5.9 / 150 8.3 / 210 11.4 / 290 14.2 / 360 16.9 / 430 0.08 0.09 0.13 0.18 0.23 0.27 OXP6X130 OXP6X150 OXP6X210 OXP6X290 OXP6X360 OXP6X430 $ 12 12 16 20 24 28 Shafts -- for use with pistol handles .47 x .47" (12x12 mm) Maximum Mounting Depth (inches) Shaft length (in/mm) 11.0 / 280 12.8 / 325 15.6 / 395 18.3 / 465 21.1 / 535 OT400 OT600 OETL-NF800 -- OETL-NF3150 OETL-NF1600-OETL-NF3150 13.3 15.0 20.5 20.9 22.8 14.6 16.4 19.1 21.8 24.6 14.5 16.3 19.1 21.9 24.6 -- 20.9 23.6 26.3 29.1 Weight (Lbs.) Catalog number List price 0.77 0.90 1.10 1.32 1.54 OXP12X280 OXP12X325 OXP12X395 OXP12X465 OXP12X535 $ 36 40 44 48 52 Catalog number List price 3 Position selector handles -- for use with .24 x .24" (6x6mm) shafts 1 18 UL/NEMA Type IEC Type Markings Color Defeatable Padlockable Weight (Lbs.) 1, 3R, 12 IP65 I/0/II, ON/OFF/ON Black Yes Yes 0.16 OHBS2AJE011 $ 40 3 Position pistol handles -- for use with .24 x .24" (6x6mm) shafts 1 UL/NEMA Type IEC Type 1, 3R, 12 1, 3R, 12, 4, 4X 1, 3R, 12 1, 3R, 12, 4, 4X IP65 IP66 IP65 IP66 Markings I/0/II, ON/OFF/ON Color Defeatable Padlockable Weight (Lbs.) Black Black Black Black Yes Yes Yes Yes Yes Yes Yes Yes 0.29 0.29 0.3 0.3 Catalog number OHB65J6E011 OHB65L6E011 OHB80J6E011 OHB80L6E011 List price $ 90 130 120 155 3 Position pistol handles -- for use with .47 x .47" (12x12mm) shafts 1 UL/NEMA Type IEC Type 1, 3R, 12 1, 3R, 12, 4, 4X 1, 3R, 12 1, 3R, 12, 4, 4X IP65 IP66 IP65 IP66 Markings I/0/II, ON/OFF/ON Color Defeatable Padlockable Weight (Lbs.) Catalog number List price Black Black Black Black Yes Yes Yes Yes Yes Yes Yes Yes 0.39 0.39 0.41 0.41 OHB145J12E011 OHB145L12E011 OHB175J12E011 OHB175L12E011 $ 130 170 140 180 1 Red/Yellow handles are available by substituting the OHB prefix with OHY. For other special handle configurations, consult factory. 18.16 1SXU000023C0202 Discount schedule H6 [DH]: Handles, shafts, accessories & lug kits Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s s co No witc nne n- he ct fus s ibl e Special configurations Accessories for double throw switches Additional poles Power poles Only one power pole per switch. Mounts on left or right side of switch (OTPS40FPN1 mounts to left side only). OTP_40FP Description For use on Weight (Lbs.) Fourth Pole OT16-OT40 OT30-OT60 OT63-OT80 OT100 0.07 0.13 0.13 0.31 Late-break/early-make OT16-OT40 OT30-60 OT63-OT80 OT100 0.07 0.13 0.13 0.31 AC Thermal amp rating AC rated voltage Catalog number List price 40 60 80 100 600 OTPS40FPN1 OTPS60FP OTPS80FP OTPS125FP $ 36 46 44 54 40 60 80 100 600 OTPL40FP OTPL60FP OTPL80FP OTPL125FP AC rated voltage Catalog number List price 36 46 44 54 Terminal poles Switch accepts one terminal pole per side. Mounts on left or right side of switch. Description Weight (Lbs.) AC Thermal amp rating Solid neutral OT16-OT40 OT63-OT80 OT30-OT100 0.07 0.13 0.31 40 80 100 600 OTPN40FP OTPN80FP OTPN125FP $ 20 36 50 Detachable Neutral OT16-OT40 OT30-OT60 OT63-OT80 OT100 0.07 0.13 0.13 0.31 40 60 80 60 600 OTPD40FP OTPD60FP OTPD80FP OTPD125FP 28 38 36 50 Ground Terminal OT16-OT40 OT30-OT60 OT63-OT80 OT100 0.07 0.13 0.13 0.31 40 60 80 100 600 OTPE40FP OTPE60FP OTPE80FP OTPE125FP 20 38 36 50 OTP_80FP OTP_125FP For use on Terminal lug kits For Use On Wire Size Wire Type Lugs/Kit Weight (Lbs) Catalog number List price OT200_C #4 - 300kcmil #4 - 300kcmil (6) 14-6 AWG Cu/Al 6 3 3 0.5 0.25 0.25 OZXA-200 OZXA-200/3 OZXA-206T $ 80 40 200 OT400_C #2 - 600kcmil #2 - 600kcmil (2) #4 - 300kcmil (6) #14 - 6 AWG Cu/Al 6 3 6 3 0.5 0.25 0.5 0.5 OZXA-400 OZXA-400/3P OZXA-402 OZXA-406 190 100 210 270 OT600_C (2) #2 - 600kcmil (2) #2 - 600kcmil Cu/Al 6 3 0.5 0.5 OZXA-800 OZXA-800/3 360 180 Auxiliary contacts -- snap-on mounting Description For Use On Weight (Lbs.) AC Thermal amp rating AC rated voltage Catalog number List price 1 N.O. 1 N.C. 1 N.O. OT16-100_C OT16-600_C OT200-600_C 0.7 0.7 0.7 10 10 10 600 600 600 OA7G10 OA3G01 OA1G10 $ 20 20 20 Mounting & installation considerations OT16-100 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage OA1G10 (1 N.O.) mounts on right side of switch only OA1G01 (1 N.C.) mounts on left side of switch only OA2G11 (1 N.O. & 1 N.C.) mounts on left or right side of switch Maximum two contacts on each side of switch Discount schedule H6 [DH]: Handles, shafts, accessories & lug kits 18.17 1SXU000023C0202 18 ct ne s n o he e l sc Di witc usib s -f n No OT800 - 1200A OT800 - 1200A 2 Pole UL general purpose amp rating IEC AC21 amp rating 800 1250 OT800U02 1200 1600 OT1200U02 3 Pole Catalog number List price 4 Pole Catalog number List price OT800U03 OT800U12 OT800U30 $ 2600 $ 4200 OT1200U03 OT1200U12 OT1200U30 6200 6800 Catalog number OT800U04 OT800U40 OT800U22 OT1200U04 OT1200U40 OT1200U22 List price $ 5200 8600 T-Style handles -- for use with .47 x .47" (12x12mm) shafts UL/NEMA Type IEC Type Color Marking Length Defeatable Padlockable 1, 3R, 12 IP65 Black O/I & Off/On 2 x 200 Yes Yes Catalog number OHB200J12P List price $ 140 Shafts for use with T-Style handles -- .47 x .47" (12x12mm) Shaft length Maximum mounting depth Weight (Lbs.) 11.0 / 280 12.8 / 325 15.6 / 395 18.3 / 465 21.1 / 535 15.2 17.0 19.7 22.4 25.2 0.77 0.90 1.10 1.32 1.54 Catalog number List price OXP12X280 OXP12X325 OXP12X395 OXP12X465 OXP12X535 $ 36 40 44 48 52 Catalog number List price OZXA-1200 $ 700 Catalog number List price Terminal lugs For use on Wire size Wire type Lugs per kit OT800 - 1200 (4) #2-600 kcmil Cu 6 Auxiliary contacts Description For use on AC thermal amp rating AC rated voltage 1 NO 1 NC Module for contacts OT800 - 1200 10 600 OA1G10 OA3G01 OEA28 $ 20 20 50 18 18.18 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Disconnect switches Fusible Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Fusible disconnect switches 30A - 800A, 600V Di s sw con n i Fu tch ect e sib s le ABB PowerLine includes seven different amperage sizes from 30A to 800A. All ABB fusible switches are designed to meet customer requirements in terms of high interrupting capacity and long electrical life while occupying little more panel space than the appropriate fuses. The basic construction provides flexibility and high performance in an extremely compact size. ABB PowerLine switches are a perfect choice to withstand the heat and humidity of the tropics, the extreme cold of the arctic and any rugged industrial environment you may have. International acceptance ABB fusible switches are available with a wide range of fuse clip options: UL USA CSA Canada DIN Europe BS United Kingdom NFC France Ultra-rapid As well as the corresponding approvals: UL listed, CSA approved, IEC rated, CE marked, and most other international standards. UL98 (CSA 22.2 No.4) -- UL File # E101914, CSA File #LR58077 For 30A - 800A switches, OH__ pistol grip handles Suitable for use as motor disconnects or industrial control panel disconnects on service entrance equipment, panelboards, switchboards, industrial control equipment, motor control centers, etc. and are horsepower rated and ampere rated. IEC Tested in accordance to IEC 947-1 and 3, IEC 664, IEC 269, and IEC 204 CE Compliance with the European Machine Directive IEC 204 (EN 60204) 18.19 1SXU000023C0202 18 ct ne s n o he sc Di witc ible s us F OS30FA_12 Selection guide OS30FACC12 - OES800L3 OS60J12 OS100J03 Catalog number 3 pole General purpose amp rating Catalog reference Approvals 1 OS30FACC12 OS200J03 OS30FAJ12 OS400J03 OS600J03 OES800L3 OS60J12 OS100J03 OS200J03 OS400J03 OS600J03 OES800L3 A 30 30 60 100 200 400 600 800 Page # 18.79 18.79 18.83 18.83 18.83 18.87 18.87 18.87 2 pole 3 pole 4 pole N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC 600 600 600 600 600 600 600 600 Technical ratings (UL,CSA) Max operating voltage V Max horsepower rating Three phase 240V 480V 600V Single phase 120V 240V UL fuse class HP HP HP 7.5 7.5 15 30 60 125 200 250 15 15 30 60 125 250 400 500 20 20 50 75 150 350 500 600 HP HP Technical ratings (IEC) Rated insulation and operational voltage. AC20 and DC20 V 2 3 2 3 -- -- -- -- -- -- -- -- -- -- -- -- CC J J J J J J L 1000 1000 1000 1000 1000 1000 1000 1000 Rated thermal current, Ith AC 20/DC 20 open AC 20/DC 20 enclosed A A 32 32 32 32 63 63 160 160 200 200 400 400 630 600 800 720 AC 21A A A 32 32 32 32 63 63 160 160 200 200 400 400 630 630 800 800 14/15 25 14/15 25 30 60 80/90 132 110 200 220/230 400 355 560 350/380 600 lb lb 1.54 1.98 1.54 1.98 2.86 3.52 3.30 3.96 5.9 7.5 12.56 15.21 28.66 37.48 37.44 46.26 H in W in D in 3.66 4.15 4.10 3.60 4.15 4.10 3.94 5.63 5.04 5.67 7.07 5.10 6.5 7.1 5.2 9.29 10.04 6.93 12.04 13.50 9.17 10.10 14.80 9.17 500V 690V Rated operational power AC23 400/415V 690V kW kW Physical characteristics Weight 3 pole switch 4 pole Dimension 3 pole Accessories 18 Double break contacts S S S S S S S S Fuse cover S S S S S S S S Terminal lug kit Integral Integral Integral OZXA-24 OZXA-200 OZXA-400 OZXA-800 OZXA-27 Terminal shroud Not required Not required Not required Auxiliary contact * * * * * * * * * * * * * Shaft/handle diameter 6mm .24 x .24" 6mm .24 x .24" 6mm .24 x .24" 6mm .24 x .24" 6mm .24 x .24" 12mm .47 x .47" 12mm .47 x .47" 12mm .47 x .47" * * * * * * * * * * * * * * * * Recommended pistol handle length Maximum recommended shaft length 45 - 65mm 290mm 45 - 65mm 290mm 45 - 65mm 290mm 45 - 65mm 290mm 65 - 80mm 290mm 125 - 175mm 595mm 125 - 175mm 595mm 125 - 175mm 595mm Electrical interlock -- -- -- -- -- * * * Handle UL/NEMA type Type 1, 3R, 12 Type 1, 3R, 4, 4X, 12 S = Standard * = Available -- = Not available 1 UL listed switches are also CSA approved. 18.20 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con n i Fu tch ect e sib s le Selection information Standard part number designation 1 Fusible OS Switches (30 to 60A) OS 30 F A J 22 F Amperage 30 = 30 amps 60 = 60 amps Fuse Type/Class J = Class J fuse compatible CC= Class CC fuse compatible Number of poles and placement of the mechanism 12 = 1 Pole to the left of mechanism, 2 poles to the right of mechanism 22 = 2 Poles to the left of mechanism, 2 poles to the right of mechanism Fusible OS Switches (100A) OS 100 J 03 Amperage 100 = 100 amps Fuse Type/Class J = Class J fuse compatible Number of poles and placement of the mechanism 03 = 3 Poles to the right of mechanism 04 = 4 poles to the right of mechanism Fusible OS Switches (200A and above) OS 200 J 04 F Amperage 200 = 200 amps 400 = 400 amps 600 = 600 amps Fuse Type/Class J = Class J fuse compatible Number of poles and placement of the mechanism Selector Handles 03 = 3 Poles to the right of mechanism 12 = 1 Pole to left of mechanism, 2 poles to right 30 = 3 Poles to the left of mechanism 04 = 4 poles to the right of mechanism 22 = 2 Poles to left of mechanism, 2 poles to right 40 = 4 Poles to the left of mechanism OHB S 1 P H Handle Color B = black Y = Red/Yellow Physical Size Connection to Switch A = external shaft Protection Class Pistol Handles H=1 P = snap on R = screw J= 1, 3R, 12 O H B 65 J 6 E011 Handle Color B = Black Y = Red/Yellow Handle Length 65 = 65mm 80 = 80mm 18 M = Stainless Steel 125 = 125mm 145 = 145m 175 = 175mm 275 = 275mm Environmental Rating J = 1, 3R, 12 L = 1, 3R, 12, 4, 4X Shaft Diameter 6 = 6mm 12 = 12mm Special Configuration E011 = 3 position transfer switch handle 1 Part designation keys are provided for reference only. Not all variations or configurations are available. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.21 1SXU000023C0202 ct ne s n o he sc Di witc ible s us F Base & DIN rail mounted 30 - 800A For a complete assembly, please select one of each: 1 switch (pg. 18.22) 1 handle (pg.18.23) 1 shaft (pg. 18.24) 1 terminal lug kit (pg. 18.25) (Only required for 100A & above.) OS400J03 + 2 Pole UL general UL Fuse purpose amp Type 600V rating 30 J CC 1 OXP12X280 + 3 Pole Catalog number List price -- -- -- -- Catalog number OS30FAJ12 OS30FACC12 OHB145J12 + 4 Pole List price $ 280 280 Catalog number OS30FAJ22F OS30FACC22F List price $ 350 350 60 J -- -- OS60J12 380 OS60J22F 490 100 J -- -- OS100J03 520 OS100J04F 660 200 J OS200J02 $ 1,240 OS200J03 OS200J30 OS200J12 1,380 1,380 1,380 OS200J04F OS200J13F OS200J22F 1,725 1,725 1,725 400 J OS400J02 1,680 OS400J03 OS400J30 OS400J12 1,860 1,860 1,860 OS400J04F 2,320 600 J OS600J02 2,600 OS600J03 OS600J30 OS600J12 4,613 4,613 4,613 OS600J04F 5,536 800 L OES800L2 4,280 OES800L3 4,760 OES800L4 5,950 UL 98 OZXA-24 18 1 Rejection style fuses only. 18.22 1SXU000023C0202 Discount schedule H4 [D4]: Fusible 30 - 100A Discount schedule H5 [D5]: Fusible 200A - 800A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con n i Fu tch ect e sib s le Standard handles & shafts OHB__J6 OHBS2AJ1 OHY__J6 OHM125L12 OHB4 Recommended handles & shafts Switch Shaft diameter Recommended standard pistol handle length Maximum recommended shaft length OS30 - 100 OS200 OS400 - 600 OES800 6x6 mm - .24 x .24" 6x6 mm - .24 x .24" 12x12 mm - .47 x .47" 12x12 mm - .47 x .47" 45 - 65 mm 65 - 80 mm 125 - 175 mm 125 - 175 mm 290 mm 290 mm 595 mm 595 mm Selector handles -- for use with .24 x .24" (6mm) OXS6X_shafts 2 3 UL/NEMA Type 1, 3R, 12 IEC type IP65 Color Black Marking O/I & Off/On Defeatable Padlockable Weight (lbs) -- Yes 0.16 OHBS2AJ1 Catalog number Yes Yes 0.16 OHBS2AJ List price $ 28 30 NOTE: Selector handles are not recommended for use with fusible switches over 30A. Pistol handles -- for use with .24 x .24" (6mm) OXP6X_ shafts 2 3 UL/NEMA Type IEC type Color Marking Length in/mm Defeatable Padlockable Weight (lbs) Catalog number 1, 3R, 12 1, 3R, 12 1, 3R, 12 1, 3R, 12, 4, 4X 1, 3R, 12, 4, 4X 1, 3R, 12 1, 3R, 12, 4, 4X IP65 IP65 IP65 IP66 IP66 IP65 IP66 Black Black Black Black Stainless Steel Black w/ stainless hasp Black w/ stainless hasp O/I & Off/On Off/On/Test O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On 2.6/65 2.6/65 3.1/80 3.1/80 2.6/65 2.6/65 2.6/65 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.29 0.29 0.30 0.30 1.60 0.31 0.31 OHB65J6 OHB65J6T 1 OHB80J6 OHB80L6 OHM65L6 OHB65J6EH OHB65L6EH List price $ 80 100 90 130 750 250 290 Pistol handles -- for use with .47 x .47" (12mm) OXP12X_ shafts 2 3 UL/NEMA Type IEC type Color Marking Length in/mm Defeatable Padlockable Weight (lbs) Yes Yes Yes Yes Yes Yes 0.39 0.39 0.41 OHB125J12 OHB145J12 OHB175J12 Catalog number List price $ 90 90 100 Yes Yes Yes Yes 0.39 0.41 OHB145L12 OHB175L12 130 140 1, 3R, 12 IP65 Black O/I & Off/On 4.9/125 5.7/145 6.9/175 1, 3R, 12, 4, 4X IP66 Black O/I & Off/On 5.7/145 6.9/175 1, 3R, 12, 4, 4X IP65 Metal Off/On 8.7/220 -- Yes 1.50 YASDA-8 4.9/125 6.9/175 275 Yes Yes Yes Yes Yes Yes 1.70 1.80 2.10 OHM125L12 OHM175L12 OHM275L12 4.9/125 Yes Yes 0.44 OHB125J12EH 6.9/175 Yes Yes 0.76 OHB175J12EH 330 4.9/125 Yes Yes 0.44 OHB125L12EH 330 6.9/175 Yes Yes 0.76 OHB175L12EH 390 1, 3R, 12, 4, 4X IP66 Stainless Steel O/I & Off/On 1, 3R, 12 IP65 Black w/ stainless hasp O/I & Off/On 1, 3R, 12, 4, 4X IP66 Black w/ stainless hasp O/I & Off/On 190 900 1,100 1,200 280 Direct mount handle 23 For use on Description Marking Color Padlockable Weight OS30 OS60-100 OS200 OS400 OS600 OS400-600, OES800 No shaft required No shaft required No shaft required No shaft required No shaft required Mounts on 12mm shaft O/I/Test O/I O/I O/I O/I -- Black Black Black Black Black Metal Yes Yes Yes Yes Yes No 0.10 0.10 0.30 0.30 0.30 0.78 Catalog number OHBS5 OHB4 OSV200BK OSV400BK OSV800BK YASDA-33 List price $ 60 60 134 173 212 155 1 The OS30_ switch has a TEST position, accessed by rotating the mechanism 45 degrees counterclockwise from the OFF position. In the TEST position, optional auxiliary contacts, OA4B1C, are actuated but the main switch contacts are not. 2 Red/Yellow handles are available by substituting the OHB prefix with OHY. 3 All handles are plastic unless otherwise noted as metal or stainless steel. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule H6 [DH]: Handles, shafts 18.23 1SXU000023C0202 18 ct ne s n o he sc Di witc ible s us F Standard handles & shafts OXP6X_ OXP12X_ OXS6X_ Shafts -- for use with OH selector handles .24 x .24" (6x6 mm) Shaft length (in/mm) Maximum mounting depth (inches) Weight (Lbs.) Catalog number List price 5.1 / 130 5.6 0.08 OXS6X130 $6 7.1 / 180 6.1 0.11 OXS6X180 6 9.8 / 250 10.3 0.13 OXS6X250 12 13 / 330 13.4 0.17 OXS6X330 20 NOTE: Selector handles and shafts are not recommended for use with fusible switches over 30A Shafts -- for use with pistol handles .24 x .24" (6x6 mm) Shaft length (in/mm) 5.9 / 150 8.3 / 210 11.4 / 290 14.2 / 360 16.9 / 430 Weight (Lbs.) Maximum mounting depth (inches) OS30 8.9 9.7 13.4 18.7 22.6 OS60 9.7 12.1 15.2 12.9 20.6 OS100 9.8 12.2 15.3 18.0 20.7 OS200 -- 9.9 13.0 -- -- 0.09 0.13 0.18 0.23 0.27 Catalog number List price $ 12 16 20 24 28 OXP6X150 OXP6X210 OXP6X290 OXP6X360 OXP6X430 Shafts -- for use with pistol handles .47 x .47" (12x12 mm) Shaft length (in/mm) 11.0 / 280 12.8 / 325 15.6 / 395 18.3 / 465 21.1 / 535 Maximum mounting depth (inches) OS400 13.8 15.6 18.3 21.0 23.8 OS600, OES800 14.9 16.7 19.4 22.1 24.8 Weight (Lbs.) Catalog number List price 0.77 0.9 1.1 1.32 1.54 OXP12X280 OXP12X325 OXP12X395 OXP12X465 OXP12X535 $ 36 40 44 48 52 18 1 Mounting depth is distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length. 18.24 1SXU000023C0202 Discount schedule H6 [DH]: Handles, shafts, accessories & lug kits Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con n i Fu tch ect e sib s le Standard fusible accessories Base & DIN rail mounted switches Auxiliary contacts -- snap-on mounting OS30FAJ12 with auxiliaries OA1G10, OA3G01 AC Thermal amp rating AC rated voltage Catalog number List price 0.04 6 250 OA4B1C $ 40 0.07 10 600 OA1G10 20 OS30 - OS600 0.07 10 600 OA3G01 20 OS30 OS200 - OS600 0.09 0.10 -- -- -- -- OSZ4 OEA28 20 50 For Use On Weight (Lbs.) Form C 1 N.O. & 1 N.C. OS30 1 N.O. OS30 - OS600 1 N.C. Module for auxiliary contacts Description Auxiliary contacts -- front mounting Description For Use On Weight (Lbs.) AC Thermal amp rating AC rated voltage Catalog number List price 1 N.O. + 1 N.C. 2 N.O. + 2 N.C. 4 N.O. + 4 N.C. OES800 0.20 0.26 0.40 10 10 10 600 600 600 OZXK-1 OZXK-2 OZXK-3 $ 100 170 340 2 N.O. 4 N.O. 8 N.O. OES800 0.18 0.25 0.4 10 10 10 600 600 600 OZXK-4 OZXK-5 OZXK-6 100 170 340 Mounting & installation considerations OS30 OS60 - 600 Form C contacts mount directly to switch Maximum two Form C contacts OA1G10 (1 N.O.) + OA3G01 (1 N.C.) require mounting base Maximum 6 OA1G10 + OA3G01 contacts with mounting base OSZ4 Mounting to left side of switch with OEA28 module: Maximum 8 contact blocks Mounting under mechanism cover: Maximum 4 contact blocks OEA28 Terminal lugs For Use On OZXA-24 Wire Size Wire Type Lugs/Kit Cu/Al 6 OZXA-24 1 $ 24 OS200 #4 - 300 kcmil #4 - 300 kcmil (6) 14-6 AWG Cu/Al 6 3 3 OZXA-200 OZXA-200/3 OZXA-206/S 80 40 200 OS400 #2 - 600 kcmil (2) #2 - 300 kcmil (2) #2 - 500 kcmil Cu/Al 6 6 6 OZXA-400 OZXA-402 OZXA-33 190 210 375 OS600 (2) #2 - 600 kcmil (2) - 600 kcmil Cu/Al 6 3 OZXA-800 OZXA-800/3 360 180 OES800 (12) #14 - 6 kcmil (2) #2 - 600 kcmil (2) #2 - 600 kcmil Cu/Al 3 6 3 OZXA-175/400 OZXA-27 OZXA-27/3P 270 380 190 OS100 #14 - 2/0 Catalog number List price 18 OZXA-27 OZXA-175/400 1 Not suitable for use on cable operated flange version of OS100. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule H6 [DH]: Handles, shafts, accessories & lug kits 18.25 1SXU000023C0202 ct ne s n o he sc Di witc ible s us F Standard fusible accessories Base & DIN rail mounted switches Additional poles Description For use on Weight (Lbs.) AC Thermal amp rating AC rated voltage Detachable neutral mounts on side of switch or DIN rail OS30 OS60 OS100 OES800 0.45 0.13 0.31 1.19 30 63 125 800 600 600 600 600 Catalog number OESA-ZX171 OSZ1 OSZ2 OESA-ZX88 List price $ 40 50 50 160 Terminal shrouds 1 OESA-ZX171 List price 0.04 0.04 OSS160T1 OSS160T3 $ 20 60 OS200 OS200 OS200 OS200 0.20 0.13 0.26 0.18 OSS200G1L/3 OSS200G1S/3 OSS200G1L/4 OSS200G1S/4 OS400 OS600 OES800 0.13 0.11 0.11 OSS403 OSS603 OESA-ZX125 190 220 160 List price For Use On Weight (Lbs.) Terminal shroud for one pole Terminal shroud for 3 poles OS100 OS100 3 pole long type shrouds 3 pole short type shrouds 4 Pole long type shrouds 4 pole Short type shrouds 3 Pole includes one shroud for line or load side 2 OSS160T3 Catalog number Description 50 50 65 61 Fuse monitors Blown fuse indicators/monitors OSS200G1S/3 OSS200G1L/3 For Use With Rated Voltage Weight (lbs) Catalog number OS30-600 and OES800 100-240 380-600 0.31 0.31 OFM240 OFM600 $ 290 290 Suitable for 1 or 3 phase circuits. Includes 1 N.O. and 1 N.C. auxiliary contacts and red & green LED lights for indication. Fuse Monitor Mounting Accessories For Use With Crimp Terminal size (mm) Catalog number List price OS30-200 2.8-0.8 OFMZX2 $ 20 OS400-600, OES800 Includes 6 crimp terminals 6.3-0.8 OFMZX4 70 For Use on Catalog number Fuse carriers/covers OESA-ZX70 OESA-ZX123 OESA-ZX125 Description CC fuse carrier (Qty. 1) J fuse carrier (Qty. 1) Solid link carrier (Qty. 1) Removable fuse carrier (Qty. 3) Removable fuse carrier (Qty. 4) Transparent fuse cover Fuse Cover 2 pole fuse cover 3 pole fuse cover 4 pole fuse cover OFM_ Fuse Cover Interlock - prevents fuse cover from being opened when the switch is in the ON position OS30AFCC_ OS30AFJ_ OS30_ OS60J12 OS60J22F List price OESAZD48 OESAZD28 OESAZD55 $ 50 50 50 OSC60J3 OSC60J4 60 200 OS100 OS200 CXBY68362 CXBY68674 20 20 OES800 OESA-ZX216 OESA-ZX196 OESA-ZX197 180 260 350 OES800 OESA-ZX204 90 18 OSC60J_ CXBY68362 OESA-ZX271 OESA-ZX216 OESA-ZX272 OESA-ZX196 OESA-ZX273 OESA-ZX197 18.26 1SXU000023C0202 1 ABB switches are IP20 touchsafe as standard. Terminal shrouds provide an extra degree of protection. 2 For 4 pole shrouds, please consult factory. Discount schedule H6 [DH]: Handles, shafts, accessories & lug kits Discount schedule H7 [DR]: Accessories & replacement parts Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con n i Fu tch ect e sib s le Standard fusible accessories Base & DIN rail mounted switches Miscellaneous accessories & replacement parts Shaft accessories Accessory Type Description For Use On Weight Catalog number List price 6mm shafts 0.2 OETL-ZK19 $ 40 Shaft Extension Coupler Joins two shafts together for applications where 6mm shafts extended length is required 12mm shafts 0.26 0.26 OESA-ZX167 OETL-ZX95 56 100 Shaft Guide Fits all pistol grip handles, mounts on the inside pistol handles of the enclosure door with provided hardware - Adapts one end of a 6m shaft to 12mm (use with shaft extension coupler) Shaft Adapter OHZX10 OHZX10 12 Locking accessories Accessory Type Description for Kirk Key, Castell, Low & Fletcher and Ronis OS60-OS200 interlock. For adapting to the interlock system. OS400-OS600 The interlock is not included. Cam Attachment OETL-ZX95 Electrical Interlock For Use On Closed circuit principle for interlocking the switch movement. When the coil circuit is dead, A-types cannot be operate to O-position and L-types cannot be operated to ON- or OFF-position. Coil voltages 110VAC, 220 VAC, 24VDC, 48VDC, 60VDC, 110VDC, 220VDC, P - 15W U = 0.7 - 1.1 Un (U = coil voltage, Un = nominal voltage) OES800 Weight Catalog number List price 0.25 0.29 OETL-ZW16 OETL-ZW5 $ 190 190 2.42 OETL-ZT80A OETL-ZT80L 1280 1220 = Coil Voltage Shorting bars Description For Use On AC thermal amp rating AC rated voltage Catalog number List price Dummy Fuse OS60 60 600 OESA-ZD54 $ 50 Solid links: metal strap OS100 OS200 100 400 600 600 OESA-ZS36 OESA-ZK98 24 23 T type fuse adapter kit OETL-ZW16 For Use on For Use with AC thermal amp rating AC rated voltage Poles Catalog number OES800 300 & 600V Class T fuse 800 600 3 OESA-ZX1-L8T6 List price $ 280 Replacement parts Item Description For use on Catalog number List price Terminal cover Phase Barrier Shaft Set Screw Covers terminal below fuse carrier - OS30_ OS200 OS30_ CXBY67121 CXBY68794 FLSWM5X8AX $ 10 15 2 DIN rail 18 OESA-ZX1-J1T6 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule H6 [DH]: Handles, shafts, accessories & lug kits 18.27 1SXU000023C0202 ct ne s n o he sc Di witc ible s us F Special configurations Shaft operated flange 30A - 100A For a complete assembly, please select one of each. Switch Handle Shaft Lug kit (as required) 30A -100A Flange operated fusible switches (Shaft) -- 3 pole Maximum horsepower rating UL general purpose amp rating UL fuse type 600V A 30 30 60 100 OS30FAJF30 J CC J J Catalog number Three phase 240V 480V 600V 7.5 7.5 15 30 15 15 30 60 20 20 50 75 List price OS30FAJF30 OS30FACCF30 OS60JF30 OS100JF30 $ 500 500 590 690 List price Flange handles UL/ NEMA type Marking Defeatable Padlockable Catalog number 1, 3R, 12 4, 4X OFF/ON OFF/ON Yes Yes Yes Yes DSFHN-HS12 DSFHN-HS4 $ 156 240 Shafts DSFHN-HS__ DSFHS-__ 18 For use with: Maximum enclosure depth (inches) OS30_ - OS100_ 16 21 26.5 Catalog number List price DSFHS-12 DSFHS-17 DSFHS-22 $ 28 40 52 Catalog number List price Terminal lug kits and accessories For use on: Description Wire size Wire type Qty. OS30_ OS60_ OS100_ Lug Lug Lug #18 - #8 #14 - #4 #14 - 2/0 Cu Cu Cu/Al --6 Integral Integral OZXA-24 -- -- $ 24 OS30_- OS100_ Aux. Contact Aux. Contact 1 NO 1 NC 1 1 OA1G10 OA3G01 20 20 OS30_ Adapter Needed for mounting aux. Contacts on OS30_ 1 OSZ4 20 OS100_ Shroud Includes one set of 3 for use on line or load side 1 OSS160T3 60 Catalog number List price Door hardware NEMA 12 Item Safety door latch, 2 point, door less than 40" high Safety door latch, 3 point, door greater than 40" high KDH2R KDH3R $ 200 225 OZXA-24 Flange operated fusible and non-fusible disconnect switches ABB's solution for complying with the new NFPA79 requirements is Flange Operated Fusible and Non-fusible Disconnect Switches. New 2002 NFPA 79 changes requires main disconnecting means to be operable without the use of accessory tools or devices, independent of door position. This code also includes an interlocking provision to prevent the closing of disconnects while the enclosure door is open, unless an interlock is operated by a deliberate action. The flange operated disconnect switches are available as ridged shaft or flexible cable operated versions. The cable operated version allows you to install the disconnect switch anywhere in the enclosure depending on the length of the cable. Cables are available in lengths up to 84 inches. OA1G__ 18.28 1SXU000023C0202 The designs are cost-effective NFPA 79 solutions offering quick and easy installation. Discount schedule H4 [D4]: Fusible 30 - 100A Discount schedule H6 [DH]: Handles, shafts, accessories and lug kits Discount schedule SH [SH]: Door hardware kits Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con n i Fu tch ect e sib s le Special configurations Cable operated flange 30A - 200A For a complete assembly, please select one each of the following: Switch Handle Cable Lug kit (as required) Operating mechanism Fusible Maximum horsepower rating UL general purpose amp rating UL fuse type 600V 30 30 60 100 200 OS200J03 Catalog number Three phase J CC J J J 240V 480V 600V 7.5 7.5 15 30 60 15 15 30 60 125 20 20 50 75 150 OS30FAJ12 OS30FACC12 OS60J12 OS100AJ30 OS200J30 List price $ 280 280 380 920 1,380 Flange handles -- UL98; File #E101914 For use with: Environmental rating NEMA 1, 3R, 12 OS30_12, OS60J12, OS100AJ30, OS200J30 Catalog number List price OHF1C12 $ 213 NEMA 4, 4X OHF1C4 243 Cable length (inches) Catalog number List price OXC1L36 OXC1L48 OXC1L60 OXC1L72 OXC1L84 $ 114 146 160 175 204 For use with: Catalog number List price OS30AFJ12, OS30AFCC12 OS60J12 OS100AJ30, OS200J30 MKCS2 MKCS3 MKCS4 $ 135 162 171 Catalog number List price $ 80 Flexible cables For use with: OHF1C12 36 48 60 72 84 OS30_12, OS60J12, OS100AJ30, OS200J30 Operating mechanisms OXC1L36OXC1L84 Terminal lug kits For use with OS100AJ30 OS200J30 18 Wire size Wire type Description Lugs per kit #4 - 300 Kcmil Cu/Al -- 6 OZXA-200 #4 - 300 Kcmil Cu/Al -- 3 OZXA-200/3 40 (6) #4-6 AWG Cu/Al Distribution lug 3 OZXA-206/S 200 Lug Kit Door hardware NEMA 12 Item Catalog number List price Safety door latch, 2 point, door less than 40" high Safety door latch, 3 point, door greater than 40" high KDH2R KDH3R $ 200 225 OZXA-200 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule H3 [D3]: Fusible 30A - 100A Discount schedule H6 [DH]: Handles, shafts, accessories and lug kits Discount schedule H5 [D5]: Fusible 200A - 800A Discount schedule SH [SH]: Door hardware kits 18.29 1SXU000023C0202 ct ne s n o he sc Di witc ible s us F Other configurations High speed fuse pattern Special type fuses For a complete assembly, please select one of each: 1 switch body 1 adapter kit 1 shaft 1 handle OESA_R_ + OESAZX_ + OXP_ + OH_ Selecting switch bodies and adapter kits Please select switch body and adapter kit according to your fuses. Switch body alone can not be used -- an adapter kit is always needed. Switch bodies -- 200A through 800A American standard Max. allowed fuse power Three phase dissipation at rated current 480V 600V Maximum horsepower rating UL general purpose amp rating 240V 3 pole 200 400 600 800 60 125 200 250 125 250 400 500 150 350 500 600 4 pole 200 400 600 800 60 125 200 250 125 250 400 500 150 350 500 600 Weight (lbs) Catalog number 22W 45W 60W 65W 15.21 17.20 37.48 37.48 OES200R03 OES400R03 OES600R03 OES800R03 22W 45W 60W 65W 17.4 19.4 46.3 46.3 OES200R04 OES400R04 OES600R04 OES800R04 List price 1 1 Fuse adapter kits -- for switches OES200 - OES400 For 3 pole switch Fuse standard DIN 43653 Catalog number For 4 pole switch List price Catalog number American standard OESAZX1-S4 OESAZX1-S5 OESAZX1-S4/4 OESAZX1-S5/4 DIN80 (DIN43653) DIN80 sizes 00 and 000 (DIN 43653) DIN110 (DIN43653) DIN140 (DIN43653) OESAZX1-S7 OESAZX1-S9 1 OESAZX1-S2 OESAZX1-S6 OESAZX1-S7/4 OESAZX1-S9/4 OESAZX1-S2/4 OESAZX1-S6/4 Flush-end, 70mm body Flush-end, 50mm body OESAZX1-S8 OESAZX1-S3 OESAZX1-S8/4 OESAZX1-S3/4 French French with micro switches OESAZX1-S10 OESAZX1-S11 OESAZX1-S10/4 OESAZX1-S11/4 List price 1 Fuse adapter kits -- for switches OES600 - OES800 Fuse standard 18 Flush end American standard DIN80, DIN 110, DIN 140 (DIN43653) Flush-end, 50mm and 70mm body French French with micro switches For 3 pole switch Catalog number For 4 pole switch List price OESAZX2-S4 OESAZX2-S2 1 OESAZX2-S3 OESAZX2-S5 OESAZX2-S6 Catalog number OESAZX2-S4/4 OESAZX2-S2/4 OESAZX2-S3/4 OESAZX2-S5/4 OESAZX2-S6/4 List price 1 Handles and shafts -- see pages 18.87 - 18.88. Selecting the right fusible disconnect for HSF fuses may be difficult. Due to UL restrictions it is not possible to give a general fuse selection table for your use. Therefore we ask you to contact ABB Inc., Wichita Falls, in application issues. Information needed is nominal current of the application and catalog number of the fuse. French style 1 Consult Factory. 18.30 1SXU000023C0202 Discount schedule H4 [D4]: Fusible, 30A - 100A Discount schedule H5 [D5]: Fusible, 200A - 800A Discount schedule H6 [DH]: Handles, shafts, accessories & lug kits Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con n i Fu tch ect e sib s le Other configurations High speed fuse pattern Standard switches For a complete assembly, please select one switch catalog number which includes: Switch body + shaft + handle Selecting switch bodies There are some HSF fuses that fit in standard pattern fusible disconnects, no adapter kits needed. DIN-style fusible disconnects -- 32A through 800A1 UL general purpose AC23A rated operational power in kW amp rating 230V 400V 500V 690V 3 pole DIN 43620 4 pole NFC Style Fuse type Weight (lbs.) Catalog number List price 3 30 60 100 100 200 400 600 800 9 18.5 45 45 70 110 180 200 15 30 80 80 132 210 315 350 22 37 110 110 170 280 400 470 30 60 132 132 230 330 540 600 DIN 000, 00 DIN 000, 00 DIN 000, 00 DIN 43653: 000/80 DIN 0, 1 DIN 0, 1, 2 DIN 3 DIN 3 2.9 2.9 3.3 3.3 16.1 18.3 35.2 39.6 OS32RD12 OS63RD12 OS160RD03 OS160RD0380 OESA250RD3 OESA400RD3 OESA630RD3 OESA800RD3 30 60 100 100 200 400 600 800 9 18.5 45 45 70 110 180 200 15 30 80 80 132 210 315 350 22 37 110 110 170 280 400 470 30 60 132 132 230 330 540 600 DIN 000, 00 DIN 000, 00 DIN 000, 00 DIN 43653: 000/80 DIN 0, 1 DIN 0, 1, 2 DIN 3 DIN 3 3.5 3.5 4.0 4.0 18.1 20.7 46.3 52.9 OS32RD22 OS63RD22 OS160RD04 OS160RD0480 OESA250RD4 OESA400RD4 OESA630RD4 OESA800RD4 3 NFC-style fusible disconnects -- 25A through 125A2 UL AC23A rated operational power in kW general purpose amp rating 230V 400V 500V 3 pole 4 pole 690V Fuse type Weight (lbs.) Catalog number List price 30 30 60 100 100 6 8 18.5 37 45 11 14 30 60 80 14 18 37 80 110 22 25 60 110 132 NFC 10x38 NFC 14x51 NFC 14x51 NFC 22x58 NFC 27x60 1.54 1.54 2.90 3.30 3.30 OS25FRF1210 OS32RF1214 OS63RF1214 OS125RF0322 OS160RF0327 3 30 30 60 100 100 6 8 18.5 37 45 11 14 30 60 80 14 18 37 80 110 22 25 60 110 132 NFC 10x38 NFC 14x51 NFC 14x51 NFC 22x58 NFC 27x60 2.00 2.00 3.50 4.00 4.00 OS25FRF2210 OS32RF2214 OS63RF2214 OS125RF0422 OS160RF0427 3 Selecting the right fusible disconnect for HSF fuses may be difficult. Due to UL restrictions it is not possible to give a general fuse selection table for your use. Therefore we ask you to contact ABB Control Inc., Wichita Falls, regarding application issues. 1 OS32 - OS160 include handle OHB65J6 and shaft OXP6X161. OESA250 - OESA400 include handle OHB125J12 and shaft OXP12X250. OESA630 - OESA800 include handle OHB145J12 and shaft OXP12X250. 2 OS25 - OS125 include handle OHB65J6 and shaft OXP6X161. 3 Consult factory. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule H4 [D4]: Fusible, 30A - 100A Discount schedule H5 [D5]: Fusible, 200A - 800A Discount schedule H6 [DH]: Handles, shafts, accessories & lug kits 18.31 1SXU000023C0202 18 ct ne s n o he sc Di witc ible s us F Other configurations BS fuse pattern 1 20A - 800A BS fuse pattern switches (20A - 32A) Handle and shaft included Catalog number number of poles OS32B12A1 Rated op. current/ Rated op. power 415V 690V Fuse type and size OS20FB12A1 OS20FB22A1N1 OS20FB22A1F 3 20 A 20A A1 3 + non-fused neutral 10 kW 15 kW 20 A 4 OS32B12A1 OS32B22A1N1 OS32B22A1F 3 32 A 32A A1 3 + non-fused neutral 15 kW 25 kW 32 A 4 OS32B12A2 OS32B22A2N1 3 3 + non-fused neutral 32 A 15 kW 32A 25 kW A2 32 A OS32B12F1 OS32B22F1N1 3 3 + non-fused neutral 32 A 15 kW 32A 25 kW F1 32 A Fuse standard BS 88-2 IEC 269-2-1 BS 88-6 BS pattern switches (32A - 800A) Handle and shaft included Fuse covers included for 200A - 800A OS63B12 OS160 NO I O OFF I O OS200B3 18 number Catalog of poles number Rated Rated operational current/ Rated operational power in operaIth tional (open) category AC23A, IEC947 [A/kW] voltage AC23/[V] [A] 230V 400V 415V 500V 690V Weight with package [kg] OS32B12 OS32B22N1 3 500 32 32/7.5 32/11 32/15 32/15 -- 42 1.3 1.6 OS63B12 OS63B22N1 3 690 63 63/15 63/30 63/30 63/30 401/30 42 1.3 1.6 OS100B12 OS100B13 OS100B01 OS100B11 3 42 690 125 100/30 100/55 100/55 100/70 501/45 1 2 1.5 1.8 0.9 1.9 OS160B12 OS160B13 OS160B01 OS160B11 3 4 690 160 100/30 100/55 100/55 100/70 501/45 1 2 1.5 1.8 0.9 1.2 OS200B3 OS200B4 OS200B1 OS200B2 3 690 200 200/57 200/100 200/110 200/140 200/180 42 1 2 7.1 8.2 5.1 6.1 OS250B3 OS250B4 3 690 250 250/70 250/132 250/140 250/170 250/230 42 7.1 8.2 OS315B3 OS315B4 OS315B1 OS315B2 3 42 690 315 315/90 315/100 315/100 315/220 315/290 1 2 7.9 8.9 5.9 6.9 OS400B3 OS400B4 OS400B1 OS400B2 3 42 690 400 400/110 400/210 400/230 400/280 400/330 1 2 8.3 9.4 6.3 7.3 OS630B3 OS630B4 OS630B1 OS630B2 3 690 630 630/180 630/315 630/340 630/400 630/540 42 1 2 16.0 21.0 6.5 11.0 OS800B3 OS800B4 OS800B1 OS800B2 3 690 800 800/200 800/350 800/380 720/470 720/600 42 1 2 18.0 24.0 6.7 12.3 BS fuses are widely used in UK, South-Africa, Australia and Hong Kong 1 Please consult factory for additional information. 2 The fourth pole is provided with a solid link which can be replaced with a fuse. 18.32 1SXU000023C0202 Discount schedule H4 [D4]: Fusible, 30A -100A Discount schedule H5 [D5]: Fusible, 200A - 800A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Other configurations DIN fuse pattern 1 32A - 800A Di s sw con n i Fu tch ect e sib s le DIN pattern switches (32A - 800A) Handle and shaft included Rated operational current/ Catalog Number OperaIth Rated operational power in number of poles tional (open) category AC23A, IEC947 [A/kW] AC23/[V] [A] 230V 400V 415V 550V OS63D12 OS160 O OFF NO I OS250P3P 690V Weight with package [kg] OS32D12 OS32D22N1 OS32D22F 3 3 + non-fused neutral 690 32 32/7.5 32/11 32/15 32/15 -- 4 1.3 1.6 1.6 OS63D12 OS63D22N1 OS63D22F 3 3 + non-fused neutral 690 63 63/15 63/30 63/30 63/30 40/30 4 1.3 1.6 1.6 OS125D12 OS125D22N1 OS125D22F OS125D01 OS125D11 3 3 + non-fused neutral 4 690 125 100/30 100/55 100/55 100/70 50/45 1 2 1.5 1.8 1.8 0.9 1.2 OS160D12 OS160D22N1 OS160D22F OS160D01 OS160D11 3 3 + non-fused neutral 4 690 160 100/30 100/55 100/55 100/70 50/45 1 2 1.5 1.8 1.8 0.9 1.2 OS250D3P OS250D4P OS250DF4P OS250D1P OS250D2P 3 3 + non-fused neutral 4 690 250 250/70 250/132 250/140 250/170 250/230 1 2 7.3 8.2 8.2 5.5 6.4 OS400D3P OS400D4P OS400DF4P OS400D1P OS400D2P 3 3 + non-fused neutral 4 690 400 400/110 400/210 400/230 400/280 400/330 1 2 8.3 9.4 9.4 6.3 7.3 OS630D3P OS630D4P OS630DF4P OS630D1P OS630D2P 3 3 + non-fused neutral 4 690 630 630/180 630/315 630/340 630/400 630/540 1 2 16.0 21.0 21.0 6.5 11.0 OS800D3P OS800D4P OS800DF4P OS800D1P OS800D2P 3 3 + non-fused neutral 4 690 800 800/200 800/350 800/380 720/470 720/600 1 2 18.0 24.0 24.0 8.5 13.0 DIN fuses are mainly used in continental Europe (excluding France below 125A), Asia, Africa and South-America 18 1 Please consult factory for additional information. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule H4 [D4]: Fusible, 30A - 100A Discount schedule H5 [D5]: Fusible, 200A - 800A 18.33 1SXU000023C0202 ct ne s n o he sc Di witc ible s us F Other configurations NFC fuse pattern 63A - 125A, 14x51 & 22x58 NFC fuse pattern switches (cylinder) (10x38) (14x51) Handle and shaft included Catalog number number of poles OS32FF1214 Rated operational current/ Rated operational power 415V 690V Fuse type and size OS25FF1210 OS25FF2210N1 OS25FF2210F 3 25 A 25A 10 x 38 3 + non-fused neutral 12 kW 22 kW 25 A 4 OS32FF1214 OS32FF2214N1 OS32FF2214F 3 32 A 32A 14 x 51 3 + non-fused neutral 15 kW 25 kW 32 A 4 Fuse standard IEC 269-2-1 IEC 269-2-1 NFC fuse pattern (cylinder fuse links), (14x51 & 22x58) Handle and shaft included number Catalog of poles number OS63F12 OS50F12 OS50F22F OS63F12 OS63F22F 3 4 3 4 Rated Rated operational power in operaIth tional (open) category AC23A, IEC947 [A/kW] voltage AC23/[V] [A] 230V 400V 415V 550V 690 690 690 690 50 50 63 63 50/15 50/15 63/18.5 63/18.5 50/25 50/25 63/30 63/30 50/25 50/25 63/30 63/30 50/33 50/33 63/37 63/37 690V Weight with package [kg] 50/45 50/45 63/60 63/60 1.3 1.6 1.3 1.6 OS100F03 OS100F04F OS100F04N1 3 4 690 125 100/30 100/45 100/55 100/60 100/90 3 + non-fuse N 2.2 2.8 2.8 OS125F03 OS125F04F OS125F04N1 3 4 3 + non-fuse N 1.3 1.6 1.6 690 690 125 125/37 125/60 125/60 125/80 125/110 690 NFC fuses are used in France and in French speaking Africa OS125F03 18 1 Please consult factory for additional information. 18.34 1SXU000023C0202 Discount schedule H4 [D4]: Fusible, 30A - 100A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con n i Fu tch ect e sib s le OS800 OS800 2 Pole UL general purpose amp rating UL Fuse type 600 V 800 L OS800L02 1200 L OS1200L02 3 Pole List price Catalog number 4 Pole List price Catalog number OS800L03 OS800L30 OS800L12 OS1200L03 $ 3605 4280 Catalog number List price $ 4760 OS800L04F $ 5950 12,200 OS1200L04F 14,640 T-Style handles -- for use with .47 x .47" (12x12mm) shafts 1 UL/NEMA Type IEC Type Color Marking Length Defeatable Padlockable 1, 3R, 12 IP65 Black O/I & Off/On 2 x 200 Yes Yes Catalog number OHB200J12P List price $ 140 Shafts for use with T-Style handles -- .47 x .47" (12x12mm) Shaft length Maximum mounting depth Weight (Lbs.) 11.0 / 280 12.8 / 325 15.6 / 395 18.3 / 465 21.1 / 535 15.2 17.0 19.7 22.4 25.2 0.77 0.90 1.10 1.32 1.54 Catalog number List price OXP12X280 OXP12X325 OXP12X395 OXP12X465 OXP12X535 $ 36 40 44 48 52 Catalog number List price Terminal lugs Wire size Wire type Lugs per kit (4) #2-600 kcmil (2) #2 - 600 kcmil (2) - 600 kcmil Cu/Al Cu/Al Cu/Al 6 6 3 For use on OS1200 OS800 OZXA-1200 OZXA-800 OZXA-800/3 $ 700 360 180 Auxiliary contacts Description For use on AC thermal amp rating AC rated voltage 1 NO 1 NC Module for contacts OS800 - 1200 10 600 Catalog number OA1G10 OA3G01 OEA28 List price $ 20 20 50 18 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.35 1SXU000023C0202 ct ne s n o he sc Di witc ible s us F Notes 18 18.36 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage ed SafeLine enclosed disconnect switches are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational convenience. They are available in a wide range of amperage ratings, are UL approved and NEMA rated to satisfy rugged industrial environments. 18 Enclosed Disconnect switches D Enclosed disconnect switches swiscon No itc ne 16A - 3150A Non-fusible h c n En -fus es t c 30A - 800A Fusible los ible Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.37 1SXU000023C0202 ct ne s n o he e l sc Di witc usib s -f ed s n No nclo E eOT UL508 Enclosed switches The eOT series of enclosed manual motor controllers are rotary operated, 3 pole, 600V Hp rated switches, housed in thermoplastic/polycarbonate enclosures suitable for wet and corrosive environments. NEMA 3R/12 EOT16U3P3-S Handle color Amp rating Auxiliary contacts Catalog number Selector Selector Selector Pistol Selector Selector Selector Pistol Selector Selector Selector Pistol Selector Selector Selector Pistol Black Black Black Black Black Black Black Black Red/Yellow Red/Yellow Red/Yellow Red/Yellow Red/Yellow Red/Yellow Red/Yellow Red/Yellow 16 40 60 80 16 40 60 80 16 40 60 80 16 40 60 80 ----1 NO 1 NO 1 NO 1 NO ----1 NO 1 NO 1 NO 1 NO EOT16U3P3-S EOT32U3P3-S EOT45U3P3-S EOT63U3P3-P EOT16U3P3-1S EOT32U3P3-1S EOT45U3P3-1S EOT63U3P3-1P EOT16U3P3-S1 EOT32U3P3-S1 EOT45U3P3-S1 EOT63U3P3-P1 EOT16U3P3-1S1 EOT32U3P3-1S1 EOT45U3P3-1S1 EOT63U3P3-1P1 $ 250 300 325 355 305 370 405 435 250 300 325 385 305 370 405 435 Black Black Black Black Black Black Black Black Red/Yellow Red/Yellow Red/Yellow Red/Yellow Red/Yellow Red/Yellow Red/Yellow Red/Yellow 16 40 60 80 16 40 60 80 16 40 60 80 16 40 60 80 ----1 NO 1 NO 1 NO 1 NO ----1 NO 1 NO 1 NO 1 NO EOT16U3P4-P EOT32U3P4-P EOT45U3P4-P EOT63U3P4-P EOT16U3P4-1P EOT32U3P4-1P EOT45U3P4-1P EOT63U3P4-1P EOT16U3P4-P1 EOT32U3P4-P1 EOT45U3P4-P1 EOT63U3P4-P1 EOT16U3P4-1P1 EOT32U3P4-1P1 EOT45U3P4-1P1 EOT63U3P4-1P1 $ 270 325 365 385 335 400 445 475 270 325 365 385 335 400 445 475 Catalog number List price NEMA 4/4X EOT16U3P4-P List price Handle type Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Accessories for eOT16 - eOT63 Description Auxiliary contacts 2 NO, mounts on right side of the switch only NC, mounts on left side of the switch only 4th pole 3 4th pole 4th pole, late-break / early-make function 4th pole 4th pole, late-break / early-make function For use on AC thermal amp rating AC rated voltage eOT16 - 63 10 10 600 600 OA1G10 OA1G01 eOT16 & eOT32 eOT45 & eOT63 40 40 80 80 600 600 600 600 OTPS40FPN1 OTPL40FP OTPS80FP OTPL80FP $ 20 20 36 36 44 44 18 1 Due to torque requirements, the eOT63 is equipped with a pistol handle for both 3X/12 & 4/4X versions. 2 Maximum number of auxiliary contacts: 2NO + 1NC. 3 Only one additional pole per switch. 18.38 1SXU000023C0202 Discount schedule H1E [DA] -- Non-fusible 16 - 100A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s s co No witc nne h c n En -fus es t clo ib se le d eOT Enclosed switches Approximate dimensions eOT16_ - eOT45U eOT16_, eOT32_ (enclosure size 1) 0,18 4,5 in mm 0,79 20 0,29 7,40 2,99 76 5,98 152 1,18 30 I ON O OFF 5,98 152 5,51 140 0,09 R2,25 6,35 161,4 1,97 50 3,94 100 1/2 " 3/4 " M25 4,55 115,5 EOT32U_ , EOT45U_ eOT45U_ 1,36 34,5 3,19 81 Knock-outs M20 Handle OHB 2AJ Knock-outs on top and bottom (enclosure size 2 with selector handle) mm in 30.5 1.20 146 5.75 188 7.40 20 0.79 40.3 1.59 88 3.46 200 7.87 188 7.40 176 6.93 3/4 " 1 " O 4.5 0.18 73 2.87 103.5 4.07 138 5.43 3/4 " 1 " 34.5 1.36 EOT32U_ , EOT45U_ eOT45U_ (enclosure size 2 with pistol grip handle) mm in 30.5 1.20 146 5.75 188 7.40 20 0.79 40.3 1.59 88 3.46 200 7.87 188 7.40 176 6.93 3/4 " 1 " 3/4 " 1 " 18 73 2.87 O 4.5 0.18 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 103.5 4.07 148.5 5.84 45 1.77 18.39 1SXU000023C0202 ct ne s n o he e l sc Di witc usib s -f ed s n No nclo E eOT63_ eOT Enclosed manual motor controllers Approximate dimensions eOT63_ (enclosure size 3 with pistol grip handle) 18 18.40 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage General information Non-fusible, fusible & lockable Di s s co No witc nne h c n En -fus es t clo ib se le d Non-Fusible UL Listed to UL 508 and UL 98. CSA approved IEC rated CE marked Modern appearance Snap on accessories include additional poles, auxiliary contacts, etc. Heavy duty disconnect, 600VAC Enclosures available in plastic, metal, or stainless steel in NEMA 1, 3R, 12, 4X, 7 & 9 environmental categories Quick make, quick brake mechanism Extremely compact size Finger-proof construction. No hazardous exposed parts 3/4/6/8 pole constructions; transfer switches and by-pass switches available Fusible UL Listed to UL 98 standards. CSA approved IEC rated CE marked Snap on accessories include fuse monitors, auxiliary contacts, etc. Enclosures available in plastic, metal, or stainless steel in NEMA 1, 3R, 12, 4X, 7 & 9 environmental categories Fuse carriers available for US standards, BS, DIN, NFC standard and for various high speed fuse patterns Modern appearance Quick make, quick brake mechanism Heavy duty disconnect, 600VAC, 200kA, Isc Extreme compact size as fuse crriers are decked above contacts Double contacts enabling feed from any direction and preventing back feed Finger-proof construction. No hazardous exposed parts 3/4/6/8 pole constructions; transfer switches and by-pass switches available Lockable Clear position indications: I-ON O-OFF Door interlocked when handle padlocked to OFF position Door interlocked when handle is in ON position. Door interlock can be defeated by authorized personnel. Pilot devices can be added Handle padlockable with up to three padlocks Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.41 1SXU000023C0202 18 ct ne s n o he e l sc Di witc usib s -f ed s n No nclo E General information Non-fusible, 16A - 3150A Switch ratings, 16 - 3150 Amps, 600V UL 98 UL 508 UL General purpose amp rating 120V Maximum horsepower rating Single phase Three phase 200V 240V 200V - 208V 240V 480V 600V Wire size for terminal lugs For wire type Approval 16 25 40 1 1.5 2 2 3 5 2 3 5 3 7.5 10 5 7.5 10 10 15 20 10 20 25 #18 - 8 #18 - 8 #18 - 8 Cu Cu Cu CSA, UL CSA, UL CSA, UL 60 80 2 2 5 5 5 5 15 20 15 20 30 40 30 40 #14 - 1 #14 - 1 Cu Cu CSA, UL CSA, UL 30 60 100 2 3 5 5 7.5 15 5 7.5 15 10 20 25 10 20 30 20 40 50 30 40 50 #14 - 4 #14 - 4 #8 - 1/0 Cu Cu Cu CSA, UL CSA, UL CSA, UL 125 7.5 200-- 400 -- 20 -- -- 20 -- -- 30 60 100 30 75 125 75 150 250 100 200 350 #8 - 1/0 #6 - 300 kcmil #2 - 600 kcmil Cu Cu Cu CSA, UL CSA, UL CSA, UL 600 800 1200 -- -- -- -- -- -- -- -- -- 150 200 -- 200 250 -- 400 500 -- 500 600 -- (2) #2 - 600 kcmil (2) #2 - 600 kcmil (4) #2 - 600 kcmil Cu Cu/Al Cu/Al CSA, UL CSA, UL CSA, UL 1600 2000 3150 1 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- (4) #2 - 600 kcmil (8) #2 - 600 kcmil (8) #2 - 600 kcmil Cu/Al Cu/Al Cu/Al CSA, UL CSA, UL IEC Handle ratings, 16 - 3150 Amps, 600V Amperage range Style NEMA Color Marking Defeatable Padlockable type Black Red/Yel Black O/I & Off/On Yes Yes Red/Yel Black Red/Yel BJ YJ B6 Y6 B6 Y6 OHBS2AJ OHYS2AJ OHBS65J6 OHYS65J6 OHBS65L6 OHYS65L6 125 - 200 Pistol 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 Black Red/Yel O/I & Off/On Yes Yes Black Red/Yel B6 Y6 B8 Y8 OHB65J6 OHY65J6 OHB80L6 OHY80L6 400 - 3150 Pistol 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 Black Red/Yel Black Red/Yel Black O/I & Off/On Red/Yel Black Red/Yel Metal B4 Y4 B7 Y7 B4 Y4 B7 Y7 8 OHB145J12 OHY145J12 OHB175J12 OHY175J12 OHB145L12 OHY145L12 OHB175L12 OHY175L12 YASDA-8 16 - 200 Pistol 1,3R,12 Black I/O/II Yes Yes B8 1,3R,4,4X,12 OHB80J6E011 OHB80L6E011 400 Pistol 1,3R,12 Black I/O/II Yes Yes B4 1,3R,4,4X,12 OHB145J12E011 OHB145L12E011 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 OHB175J12E011 OHB175L12E011 YASDA-21 YASDA-6 18 Catalog number 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 16 - 100 Selector Selector Pistol Pistol Pistol Pistol Catalog number suffix 400 - 3150 1 IEC rated only. 18.42 1SXU000023C0202 Pistol Pistol Metallic Metallic Black Black I/O/II Metal Metal Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes No No Discount schedule H1E [DA]: Non-Fusible, 16A - 100A Discount schedule H2E [DB]: Non-Fusible, 125A - 800A Discount schedule H3E [DC]: Non-Fusible, 1200A - 3150A B7 B7 21 6 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con n i Fu tch ect e s En ib s clo le se d General information Fusible, 30A - 800A Switch ratings Maximum horsepower rating UL general purpose amp rating 120V 200V 30 60 100 200 400 600 800 2 3 5 -- -- -- -- 3 7.5 10 -- -- -- -- Single phase Three phase Wire size for terminal lugs 240V 200V 208V 240V 480V 600V 5 10 15 -- -- -- -- 5 15 25 50 100 150 200 7.5 15 25 50 125 150 200 7.5 15 30 60 125 200 250 15 30 60 125 250 400 500 20 50 75 150 350 500 600 #18 #14 #14 #6 #2 (2) #2 (2) #2 - - - - - - - 8 4 2/0 300 kcmil 600 kcmil 600 kcmil 600 kcmil For wire type Approval 1 Cu Cu Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al CSA, UL CSA, UL CSA, UL CSA, UL CSA, UL CSA, UL CSA, UL Catalog number suffix Catalog number Handle ratings Amperage range Style NEMA Color Marking Defeatable Padlockable type 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 Black Red/Yel Black O/I & Off/On Yes Yes Red/Yel Black Red/Yel BJ YJ B6 Y6 B6 Y6 OHBS2AJ OHYS2AJ OHBS65J6 OHYS65J6 OHBS65L6 OHYS65L6 60 - 200 Pistol 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 Black Red/Yel Black O/I & Off/On Yes Yes Red/Yel Black Red/Yel B6 Y6 B8 Y8 B8 Y8 OHB65J6 OHY65J6 OHB80J6 OHB80J6 OHB80L6 OHY80L6 400 - 800 Pistol 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R 4,4X,12 1,3R,4,4X,12 1,3R 4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 Black Red/Yel Black Red/Yel Black O/I & Off/On Red/Yel Black Red/Yel Metal B4 Y4 B7 Y7 B4 Y4 B7 Y7 8 OHB145J12 OHY145J12 OHB175J12 OHY175J12 OHB145L12 OHY145L12 OHB175L12 OHY175L12 YASDA-8 30 Selector Selector Pistol Pistol Pistol Pistol Yes Yes Yes Yes Yes Yes Yes Yes Yes No Pistol 30 1,3R,12 Black I/O/II Yes Yes B6 1,3R,4,4X,12 OHB65J6E011 OHB65L6E011 60 - 200 Pistol 1,3R,12 Black I/O/II Yes Yes B8 1,3R,4,4X,12 OHB80J6E011 OHB80L6E011 1,3R,12 1,3R,4,4X,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 OHB145J12E011 OHB145L12E011 OHB175J12E011 OHB175L12E011 YASDA-21 YASDA-6 400 - 800 Pistol Pistol Pistol Pistol Metallic Metallic Black Black Black I/O/II Black Metal Metal Yes Yes Yes Yes Yes No No B4 B4 B7 B7 21 6 18 1 Fusible switches are UL listed to the UL98 standard. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule H4E [DD]: Fusible, 30A - 100A Discount schedule H5E: [DE] Fusible, 200A - 3150A 18.43 1SXU000023C0202 ct ne s n o he e l sc Di witc usib s -f ed s n No nclo E 3 pole 16A - 3150A NF32X-3PB6C NF63X-3PB6A 3 Pole, 600V, 16A - 80A Selector handle NEMA Enclosure type 1 3R 4 UL general purpose amp rating Catalog number List price Catalog number List price 16 25 40 NF161-3PBJC NF251-3PBJC NF321-3PBJC $ 185 190 205 NF163-3PBJC NF253-3PBJC NF323-3PBJC $ 259 264 279 60 80 NF451-3PBJB NF631-3PBJA 245 280 NF453-3PBJB NF633-3PBJA 320 354 UL 508 Catalog number 4X Stainless List price Catalog number Not available with selector handle List price Not available with selector handle 3 Pole, 600V, 16A - 3150A Pistol handle NEMA Enclosure type 1 3R 4 List price Catalog number List price Catalog number List price Catalog number List price NF16X-3PB6C 2 NF25X-3PB6C 2 NF32X-3PB6C 2 $ 585 590 605 16 25 40 NF161-3PB6C NF251-3PB6C NF321-3PB6C $ 235 240 255 NF163-3PB6C NF253-3PB6C NF323-3PB6C $ 309 314 329 NF164-3PB6A NF254-3PB6A NF324-3PB6A $ 475 480 495 60 80 NF451-3PB6B NF631-3PB6A 295 330 NF453-3PB6B NF633-3PB6A 370 404 NF454-3PB6B NF634-3PB6A 525 550 30 60 100 NF301-3PB6C NF601-3PB6C NF1001-3PB6B 510 560 610 NF303-3PB6C NF603-3PB6C NF1003-3PB6B 780 830 880 NF304-3PB6C NF604-3PB6C NF1004-3PB6B 1,090 1,140 1,190 NF30X-3PB6C NF60X-3PB6C NF100X-3PB6B 1,200 1,250 1,300 125 200 NF1251-3PB6A NF2001-3PB8B 1,100 1,300 NF1253-3PB6A NF2003-3PB8B 1,400 1,650 NF1254-3PB8A NF2004-3PB8B 2,800 3,520 NF125X-3PB8A NF200X-3PB8B 3,500 4,400 400 600 NF4001-3PB4B NF6001-3PB7B 2,600 4,800 NF4003-3PB4B NF6003-3PB7B 2,800 5,000 NF4004-3PB4B NF6004-3PB7B 6,400 9,600 NF400X-3PB4B NF600X-3PB7B 8,000 12,000 800 1200 NF8001-3PB4A NF12001-3PB4A 8,000 10,000 NF8003-3PB4A NF12003-3PB4A 9,400 11,800 NF8004-3PB4A NF12004-3PB4A 15,200 18,000 NF800X-3PB4A NF1200X-3PB4A 19,000 22,500 1600 2000 3150 1 NF16001-3P8A NF20001-3P8A NF31501-3P8A 19,000 23,000 28,000 NF16003-3P8A NF20003-3P8A NF31503-3P8A 20,800 25,000 30,000 NF16004-3P8A NF20004-3P8A NF31504-3P8A 30,400 35,200 39,200 NF1600X-3P8A NF2000X-3P8A NF3150X-3P8A 38,000 44,000 49,000 UL 508 18 Catalog number UL 98 UL general purpose amp rating 4X Stainless NOTE: NF45X-3PB6B NF63X-3PB6A 635 660 All enclosed switches are provided with a black handle; however, most handles can be substituted with a red and yellow handle if desired. Please substitute the handle suffix code (2nd and 3rd from last characters) with the red/yellow handle catalog number suffix from page 18.130. There is no additional price adder for changing to a red/yellow handle of equal ratings and style. EXAMPLE: A red/yellow selector handle for an NF161-3PBJA can be substituted for the black selector handle by using the "YJ" suffix instead of the "BJ" suffix, new catalog #NF161-3PYJA. 1 IEC rated only. 2 New Washdown. 18.44 1SXU000023C0202 Discount schedule H1E [DA]: Non-fusible, 16A - 100A Discount schedule H2E [DB]: Non-fusible, 125A - 800A Discount schedule H3E [DC]: Non-fusible, 1200A - 3150A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s s co No witc nne h c n En -fus es t clo ib se le d 3 pole 16A - 3150A NF25P-3PY6A 3 Pole, 600V, 16A - 80A Selector handle UL general purpose amp rating NEMA Enclosure type 12 Plastic Catalog number 12 List price Catalog number 7&9 List price Catalog number List price 16 16, oversize 25 25, oversize 40 40, oversize NF16P-3PBJA -- NF25P-3PBJA -- NF32P-3PBJA -- $ 295 -- 300 -- 315 -- NF162-3PBJC -- NF252-3PBJC -- NF322-3PBJC -- $ 259 -- 264 -- 279 -- -- -- -- -- -- -- -- -- -- -- -- -- 60 80 NF45P-3PBJB NF63P-3PBJA 350 380 NF452-3PBJB NF632-3PBJA 320 354 -- -- -- -- UL 508 3 Pole, 600V, 16A - 3150A Pistol handle UL general purpose 4X Plastic 12 Catalog number List price Catalog number 7&9 List price Catalog number List price 16 25 40 NF16P-3PB6A NF25P-3PB6A NF32P-3PB6A $ 345 350 365 NF162-3PB6C NF252-3PB6C NF322-3PB6C $ 309 314 329 NF167-3P NF257-3P NF327-3P $ 1,900 1,925 1,950 60 80 NF45P-3PB6B NF63P-3PB6A 400 430 NF452-3PB6B NF632-3PB6A 370 400 NF457-3P NF637-3P 3,600 3,630 30 60 100 NF30P-3PB6B NF60P-3PB6B NF100P-3PB6B 875 925 975 NF302-3PB6B NF602-3PB6C NF1002-3PB6B 780 830 880 NF307-3P NF607-3P NF1007-3P 4,150 4,200 4,250 125 200 NF125P-3PB8A NF200P-3PB8B 3,000 4,000 NF1252-3PB6A NF2002-3PB8B 1,400 1,600 -- -- -- -- 400 600 NF400P-3PB4B NF600P-3PB7B 6,000 10,000 NF4002-3PB4B NF6002-3PB7B 2,900 5,100 -- -- -- -- 800 1200 NF800P-3PB4A NF1200P-3PB4A 16,000 19,000 NF8002-3PB4A NF12002-3PB4A 8,400 10,400 -- -- -- -- NF16002-3P8A NF20002-3P8A NF31502-3P8A 19,400 23,400 28,400 -- -- -- -- -- -- UL 508 UL 98 amp rating NEMA Enclosure type 1600 2000 3150 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage -- -- -- -- -- -- Discount schedule H1E [DA]: Non-fusible, 16A - 100A Discount schedule H2E [DB]: Non-fusible, 125A - 800A Discount schedule H3E [DC]: Non-fusible, 1200A - 3150A 18 18.45 1SXU000023C0202 ct ne s n o he e l sc Di witc usib s -f ed s n No nclo E 2 pole 1 125A - 3150A 2 Pole, 600V, 125A - 3150A NEMA Enclosure type 1 3R 4 UL general purpose amp rating 4X Stainless Catalog number List price Catalog number List price Catalog number List price Catalog number List price 125 200 NF1251-2PB6A NF2001-2PB8C $ 825 1,170 NF1253-2PB6A NF2003-2PB8C $ 1,050 1,485 NF1254-2PB8A NF2004-2PB8C $ 2,100 3,170 NF125X-2PB8A NF200X-2PB8C $ 2,625 3,960 400 600 NF4001-2PB4C NF6001-2PB7B 2,340 4,320 NF4003-2PB4C NF6003-2PB7B 2,520 4,500 NF4004-2PB4C NF6004-2PB7B 5,750 8,640 NF400X-2PB4C NF600X-2PB7B 7,200 10,800 800 1200 NF8001-2PB4A NF12001-2PB4A 7,200 9,000 NF8003-2PB4A NF12003-2PB4A 8,460 10,620 NF8004-2PB4A NF12004-2PB4A 13,680 16,200 NF800X-2PB4A NF1200X-2PB4A 17,100 20,250 1600 2000 3150 NF16001-2P8A NF20001-2P8A NF31501-2P8A NF16003-2P8A NF20003-2P8A NF31503-2P8A 18,720 22,500 27,000 NF16004-2P8A NF20004-2P8A NF31504-2P8A 27,360 31,680 35,280 NF1600X-2P8A NF2000X-2P8A NF3150X-2P8A 34,200 39,600 44,100 UL98 2 Pole, 600V, 125A - 3150A UL general purpose amp rating 17,100 20,700 25,200 NEMA Enclosure type 4X Plastic 12 Catalog number List price Catalog number List price 125 200 NF125P-2PB8A NF200P-2PB8C $ 2,250 3,600 NF1252-2PB6A NF2002-2PB8C $ 1,050 1,440 400 600 NF400P-2PB4C NF600P-2PB7B 5,400 9,000 NF4002-2PB4C NF6002-2PB7B 2,610 4,590 800 1200 NF800P-2PB4A NF1200P-2PB4A 14,400 17,100 NF8002-2PB4A NF12002-2PB4A 7,560 9,360 1600 2000 3150 1 UL 98 -- -- -- -- -- -- NF16002-2P8A NF20002-2P8A NF31502-2P8A 17,460 21,060 25,560 18 1 16A - 100A switches are not available in 2 pole versions; use 3 pole. 18.46 1SXU000023C0202 Discount schedule H2E [DB]: Non-fusible, 125A - 800A Discount schedule H3E [DC]: Non-fusible, 1200A - 3150A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s s co No witc nne h c n En -fus es t clo ib se le d 4 pole 16A - 3150A 4 Pole, 600V, 16A - 3150A NEMA Enclosure type 1 3R 4 UL general purpose amp rating Catalog number List price Catalog number List price Catalog number 4X Stainless List price Catalog number List price 16 25 40 NF161-4PB6C NF251-4PB6C NF321-4PB6C $ 295 300 321 NF163-4PB6C NF253-4PB6C NF323-4PB6C $ 369 374 384 NF164-4PB6A NF254-4PB6A NF324-4PB6A $ 530 535 545 NF16X-4PB6C NF25X-4PB6C NF32X-4PB6C $ 665 670 680 60 80 NF451-4PB6B NF631-4PB6A 360 410 NF453-4PB6B NF633-4PB6A 434 484 NF454-4PB6B NF634-4PB6A 570 595 NF45X-4PB6B NF63X-4PB6A 700 740 30 60 100 NF301-4PB6B NF601-4PB6B NF1001-4PB6B 650 700 750 NF303-4PB6B NF603-4PB6B NF1003-4PB6B 988 1,038 1,088 NF304-4PB6B NF604-4PB6B NF1004-4PB6B 1,200 1,250 1,300 NF30X-4PB6B NF60X-4PB6B NF100X-4PB6B 1,525 1,575 1,625 125 200 NF1251-4PB6A NF2001-4PB8B 1,375 1,625 NF1253-4PB6A NF2003-4PB8B 1,675 2,063 NF1254-4PB6A NF2004-4PB8B 3,500 4,400 NF125X-4PB8A NF200X-4PB8B 4,375 5,500 400 600 NF4001-4PB4B NF6001-4PB7B 3,250 6,000 NF4003-4PB4B NF6003-4PB7B 3,500 6,250 NF4004-4PB4B NF6004-4PB7B 8,000 12,000 NF400X-4PB4B NF600X-4PB7B 10,000 15,000 800 1200 NF8001-4PB4A NF12001-4PB4A 10,000 12,500 NF8003-4PB4A NF12003-4PB4A 11,750 14,750 NF8004-4PB4A NF12004-4PB4A 19,000 22,500 NF800X-4PB4A NF1200X-4PB4A 23,750 28,125 1600 2000 3150 1 NF16001-4P8A NF20001-4P8A NF31501-4P8A 23,750 28,750 35,000 NF16003-4P8A NF20003-4P8A NF31503-4P8A 26,000 31,250 37,500 NF16004-4P8A NF20004-4P8A NF31504-4P8A 38,800 44,000 49,000 NF1600X-4P8A NF2000X-4P8A NF3150X-4P8A 47,500 55,000 61,250 UL98 UL508 4 Pole, 600V, 16A - 3150A NEMA Enclosure type 4X Plastic 12 7&9 Catalog number List price Catalog number List price Catalog number List price 16 25 40 NF16P-4PB6A NF25P-4PB6A NF32P-4PB6A $ 405 410 420 NF162-4PB6C NF252-4PB6C NF322-4PB6C $ 369 374 384 NF167-4P NF257-4P NF327-4P $ 2,025 2,050 2,075 60 80 NF45P-4PB6B NF63P-4PB6A 465 510 NF452-4PB6B NF632-4PB6A 434 484 NF457-4P NF637-4P 3,700 3,730 30 60 100 NF30P-4PB6B NF60P-4PB6B NF100P-4PB6B 1,100 1,150 1,200 NF302-4PB6B NF602-4PB6B NF1002-4PB6B 925 975 1,025 NF307-4P NF607-4P NF1007-4P 4,300 4,350 4,400 125 200 NF125P-4PB8A NF200P-4PB8B 3,750 5,000 NF1252-4PB6A NF2002-4PB8B 1,750 2,000 -- -- -- -- 400 600 NF400P-4PB4B NF600P-4PB7B 7,500 12,500 NF4002-4PB4B NF6002-4PB7B 3,625 6,375 -- -- -- -- 800 1200 NF800P-4PB4A NF1200P-4PB4A 20,000 23,750 NF8002-4PB4A NF12002-4PB4A 10,500 13,000 -- -- -- -- 1600 2000 3150 NF16002-4P8A NF20002-4P8A NF31502-4P8A 24,250 29,240 35,500 -- -- -- -- -- -- UL508 UL 98 UL general purpose amp rating -- -- -- -- -- -- 18 1 IEC rated only. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule H1E [DA]: Non-fusible, 16A - 100A Discount schedule H2E [DB]: Non-fusible, 125A - 800A Discount schedule H3E [DC]: Non-fusible, 1200A - 3150A 18.47 1SXU000023C0202 ct ne s n o he e l sc Di witc usib s -f ed s n No nclo E 6 pole 16A - 1200A 6 Pole, 600V, 16A - 1200A 1 3R Catalog number List price Catalog number 4 List price Catalog number 4X Stainless List price Catalog number List price 16 25 40 NF161-6PB6C NF251-6PB6C NF321-6PB6C $ 580 590 610 NF163-6PB6C NF253-6PB6C NF323-6PB6C $ 728 738 758 NF164-6PB6A NF254-6PB6A NF324-6PB6A $ 1,080 1,090 1,110 NF16X-6PB6C NF25X-6PB6C NF32X-6PB6C $ 1,350 1,360 1,380 60 80 NF451-6PB6B NF631-6PB6A 690 770 NF453-6PB6B NF633-6PB6A 838 918 NF454-6PB6B NF634-6PB6A 1,140 1,185 NF45X-6PB6B NF63X-6PB6A 1,430 1,480 30 60 100 NF301-6PB6B NF601-6PB6C NF1001-6PB6B 1,230 850 1,330 NF303-6PB6B NF603-6PB6B NF1003-6PB6B 1,770 1,820 1,870 NF304-6PB6B NF604-6PB6B NF1004-6PB6B 2,110 2,160 2,210 NF30X-6PB6B NF60X-6PB6B NF100X-6PB6B 2,660 2,710 2,760 125 200 NF1251-6PB2A NF2001-6PB4B 2,200 2,950 NF1253-6PB2A NF2003-6PB4B 3,280 3,650 NF1254-6PB4A NF2004-6PB4B 5,600 7,320 NF125X-6PB4A NF200X-6PB4B 7,000 9,150 400 600 NF4001-6PB8B NF6001-6PB8B 5,860 9,960 NF4003-6PB8B NF6003-6PB8B 5,960 10,360 NF4004-6PB8B NF6004-6PB8B 13,090 19,490 NF400X-6P8B NF600X-6P8B 16,360 16,360 800 1200 NF8001-6PB8A NF12001-6P8A 16,360 20,360 NF8003-6PB4A NF12003-6PB4A 19,800 23,960 NF8004-6PB4A NF12004-6P8A 30,690 36,290 NF800X-6P8A NF1200X-6P8A 38,360 45,360 UL508 UL98 UL general purpose amp rating 1 NEMA Enclosure type 6 Pole, 600V, 16A - 1200A 4X Plastic 12 NEMA Enclosure type 7&9 UL general purpose amp rating Catalog number List price Catalog number List price Catalog number IP65 Plastic List price Catalog number List price 16 25 40 NF16P-6PB6A NF25P-6PB6A NF32P-6PB6A $ 800 810 830 NF162-6PB6C NF252-6PB6C NF322-6PB6C $ 728 738 758 NF167-6P NF257-6P NF327-6P $ 3,750 3,775 3,800 NF16E-6PBJB NF25E-6PBJB NF32E-6PBJB $ 410 420 450 60 80 NF45P-6PB6B NF63P-6PB6A 930 1,030 NF452-6PB6B NF632-6PB6A 838 918 NF457-6P NF637-6P 4,275 4,325 NF45E-6PBJB NF63E-6PBJB 520 770 30 60 100 NF30P-6PB6B NF60P-6PB6B NF100P-6PB6B 1,900 1,950 2,000 NF302-6PB6B NF602-6PB6B NF1002-6PB6B 1,670 1,720 1,770 -- -- -- -- -- -- NF30E-6PB6B NF60E-6PB6B NF100E-6PB6B 125 200 NF125P-6PB4A NF200P-6PB4B 6,000 8,350 NF1252-6PB4A NF2002-6PB4B 2,800 3,550 -- -- -- -- -- -- -- -- 400 600 NF400P-6P8B NF600P-6P8B 12,360 20,360 NF4002-6P8B NF6002-6P8B 6,160 10,560 -- -- -- -- -- -- -- -- 800 1200 NF800P-6P8A NF1200P-6P8A 32,360 38,360 NF8002-6P8A NF12002-6P8A 17,800 21,800 -- -- -- -- -- -- -- -- UL 98 UL508 1,230 1,280 1,330 18 1 = Three poles 18.48 1SXU000023C0202 Discount schedule H1E [DA]: Non-fusible, 16A - 100A Discount schedule H2E [DB]: Non-fusible, 125A - 800A Discount schedule H3E [DC]: Non-fusible, 1200A - 3150A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s s co No witc nne h c n En -fus es t clo ib se le d 3 pole double throw 16A - 1200A 3 Pole, 600V, 16A - 1200A NEMA Enclosure type 1 3R 4 UL general purpose amp rating Catalog number List price Catalog number List price Catalog number 4X Stainless List price Catalog number List price 16 25 40 NF161-3TB8C NF251-3TB8C NF321-3TB8C $ 760 770 790 NF163-3TB8C NF253-3TB8C NF323-3TB8C $ 908 918 954 NF164-3TB8C NF254-3TB8C NF324-3TB8C $ 1,200 1,230 1,260 NF16X-3TB8C NF25X-3TB8C NF32X-3TB8C $ 1,850 1,880 1,950 60 80 NF451-3TB8B NF631-3TB8A 870 950 NF453-3TB8B NF633-3TB8A 1,018 1,098 NF454-3TB8B NF634-3TB8A 1,340 1,420 NF45X-3TB8B NF63X-3TB8A 3,500 3,600 30 60 100 NF301-3TB8B NF601-3TB8B NF1001-3TB8B 1,410 1,460 1,510 NF303-3TB8B NF603-3TB8B NF1003-3TB8B 1,830 1,880 1,930 NF304-3TB8B NF604-3TB8B NF1004-3TB8B 2,400 2,450 2,500 NF30X-3TB8B NF60X-3TB8B NF100X-3TB8B 3,900 3,950 4,000 125 200 NF1251-3TB8A NF2001-3TB4B 2,380 3,150 NF1253-3TB8A NF2003-3TB4B 2,980 3,850 NF1254-3TB8A NF2004-3TB4B 3,500 7,480 NF125X-3TB8A NF200X-3TB4B 5,000 9,350 400 600 NF4001-3TB4B NF6001-3TB4A 5,960 10,260 NF4003-3TB4B NF6003-3TB4B 6,160 10,660 NF4004-3TB4B NF6004-3TB4A 13,250 19,730 NF400X-3TB4B NF600X-3TB4A 16,560 24,660 800 1200 NF8001-3TB4A NF12001-3TB4A 16,660 20,660 NF8003-3TB4A NF12003-3TB4A 19,460 24,260 NF8004-3TB4A NF12004-3TB4A 30,920 36,530 NF800X-3TB4A NF1200X-3TB4A 38,660 45,660 UL98 UL508 3 Pole, 600V, 16A - 1200A NEMA Enclosure type 4X Plastic 12 UL general purpose amp rating Catalog number List price Catalog number List price 16 25 40 NF16P-3TB8A NF25P-3TB8A NF32P-3TB8A $ 1,000 1,040 1,100 NF162-3TB8C NF252-3TB8C NF322-3TB8C $ 908 918 938 60 80 NF45P-3TB8B NF63P-3TB8A 1,180 1,260 NF452-3TB8B NF632-3TB8A 1,018 1,098 30 60 100 NF30P-3TB8B NF60P-3TB8B NF100P-3TB8B 2,000 2,050 2,100 NF302-3TB8B NF602-3TB8B NF1002-3TB8B 1,730 1,830 1,930 125 200 NF125P-3TB8A NF200P-3TB4B 3,200 8,550 NF1252-3TB8A NF2002-3TB4B 2,980 3,750 400 600 NF400P-3TB4B NF600P-3TB4A 12,560 20,660 NF4002-3TB4B NF6002-3TB4A 6,460 10,760 800 1200 NF800P-3TB4A NF1200P-3TB4A 32,660 38,660 NF8002-3TB4A NF12002-3TB4A 17,460 21,460 UL 98 UL508 18 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule HT1E: Non-fusible, double throw, 16A - 100A Discount schedule H2E [DB]: Non-fusible, 125A - 800A Discount schedule H3E [DC]: Non-fusible, 1200A - 3150A 18.49 1SXU000023C0202 ct ne s n o he e l sc Di witc usib s -f ed s n No nclo E 3 pole bypass 16A - 1200A 3 Pole, 600V, 16A - 1200A NEMA Enclosure type 1 3R 4 UL general purpose amp rating Catalog number List price Catalog number List price Catalog number 4X Stainless List price Catalog number List price 16 25 40 NF161-3BB8A NF251-3BB8A NF321-3BB8A $ 1,045 1,060 1,090 NF163-3BB8A NF253-3BB8A NF323-3BB8A $ 1,267 1,282 1,297 NF164-3BB8A NF254-3BB8A NF324-3BB8A $ 1,480 1,540 1,600 NF16X-3BB8A NF25X-3BB8A NF32X-3BB8A $ 3,740 3,820 3,900 60 80 NF451-3BB8B NF631-3BB8A 1,215 1,340 NF453-3BB8B NF633-3BB8A 1,312 1,432 NF454-3BB8B NF634-3BB8A 1,750 1,850 NF45X-3BB8B NF63X-3BB8A 4,050 4,150 30 60 100 NF301-3BB8B NF601-3BB8B NF1001-3BB8B 1,970 2,070 2,170 NF303-3BB8B NF603-3BB8B NF1003-3BB8B 2,300 2,400 2,500 NF304-3BB8B NF604-3BB8B NF1004-3BB8B 2,800 2,900 3,000 NF30X-3BB8B NF60X-3BB8B NF100X-3BB8B 4,800 4,900 5,000 125-- 200 -- 400 600 NF4001-3B6B NF6001-3B6B 8,460 15,060 NF4003-3B6B NF6003-3B6B 9,060 15,660 NF4004-3B6B NF6004-3B6B 19,750 29,330 NF400X-3B6B NF600X-3B6B 24,660 36,660 800 1200 NF8001-3B6A NF12001-3B6A 24,660 30,660 NF8003-3B6A NF12003-3B6A 28,860 30,060 NF8004-3B6A NF12004-3B6A 46,130 55,040 NF800X-3B6A NF1200X-3B6A 57,660 68,800 UL98 UL508 -- -- -- -- -- -- -- -- -- -- -- -- -- -- 3 Pole, 600V, 16A - 1200A NEMA Enclosure type 4X Plastic 12 UL general purpose amp rating Catalog number List price Catalog number List price 16 25 40 NF16P-3BB8A NF25P-3BB8A NF32P-3BB8A $ 1,300 1,325 1,350 NF162-3BB8A NF252-3BB8A NF322-3BB8A $ 1,267 1,282 1,297 60 80 NF45P-3BB8B NF63P-3BB8A 1,420 1,550 NF452-3BB8B NF632-3BB8A 1,312 1,432 30 60 100 NF30P-3BB8B NF60P-3BB8B NF100P-3BB8B 2,400 2,500 2,600 NF302-3BB8B NF602-3BB8B NF1002-3BB8B 2,300 2,400 2,500 125 200 -- -- 400 600 NF400P-3B6B NF600P-3B6B 18,660 30,660 NF4002-3B6B NF6002-3B6B 9,360 15,960 800 1200 NF800P-3B6A NF1200P-3B6A 48,660 57,660 NF8002-3B6A NF12002-3B6A 25,860 31,860 UL 98 UL508 -- -- -- -- -- -- 18 18.50 1SXU000023C0202 Discount schedule H2E [DB]: Non-fusible, 125A - 800A Discount schedule H3E [DC]: Non-fusible, 1200A - 3150A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s s co No witc nne h c n En -fus es t clo ib se le d 3 pole mechanically interlocked 16A - 1200A 3 Pole, 600V, 16A - 1200A NEMA Enclosure type 1 3R 4 UL general purpose amp rating 4X Stainless Catalog number List price Catalog number List price Catalog number List price Catalog number List price 16 25 40 NF161-3MB6A NF251-3MB6A NF321-3MB6A $ 640 650 670 NF163-3MB6A NF253-3MB6A NF323-3MB6A $ 788 798 818 NF164-3MB6A NF254-3MB6A NF324-3MB6A $ 1,120 1,160 1,170 NF16X-3MB6A NF25X-3MB6A NF32X-3MB6A $ 1,410 1,420 1,440 60 80 NF451-3MB6B NF631-3MB6A 750 830 NF453-3MB6B NF633-3MB6A 908 978 NF454-3MB6B NF634-3MB6A 1,200 1,245 NF45X-3MB6B NF63X-3MB6A 1,490 1,540 30 60 100 NF301-3MB6B NF601-3MB6B NF1001-3MB6B 1,290 1,340 1,390 NF303-3MB6B NF603-3MB6B NF1003-3MB6B 1,830 1,880 1,930 NF304-3MB6B NF604-3MB6B NF1004-3MB6B 2,170 2,210 2,270 NF30X-3MB6B NF60X-3MB6B NF100X-3MB6B 2,700 2,770 2,800 125 200 NF1251-3MB6A NF2001-3MB8B 2,260 3,010 NF1253-3MB6A NF2003-3MB8B 2,860 3,710 NF1254-3MB8A NF2004-3MB8B 5,660 7,380 NF125X-3MB8A NF200X-3MB8B 7,060 9,210 400 600 NF4001-3MB4B NF6001-3MB4B 5,920 10,020 NF4003-3MB4B NF6003-3MB4B 6,030 10,420 NF4004-3MB4B NF6004-3MB4B 13,150 19,550 NF400X-3MB4B NF600X-3MB4B 16,420 24,420 800 1200 NF8001-3MB4A NF12001-3MB4A 16,420 20,420 NF8003-3MB4A NF12003-3MB4A 19,860 24,020 NF8004-3MB4A NF12004-3MB4A 30,750 36,350 NF800X-3MB4A NF1200X-3MB4A 38,420 45,420 UL98 UL508 3 Pole, 600V, 16A - 1200A NEMA Enclosure type 4X Plastic 12 UL general purpose amp rating Catalog number List price Catalog number List price 16 25 40 NF16P-3MB6A NF25P-3MB6A NF32P-3MB6A $ 860 870 890 NF162-3MB6A NF252-3MB6A NF322-3MB6A $ 788 798 818 60 80 NF45P-3MB6B NF63P-3MB6A 990 1,090 NF452-3MB6B NF632-3MB6A 908 978 30 60 100 NF30P-3MB6B NF60P-3MB6B NF100P-3MB6B 1,900 1,950 2,000 NF302-3MB6B NF602-3MB6B NF1002-3MB6B 1,830 1,880 1,930 125 200 NF125P-3MB8A NF200P-3MB8B 6,000 8,350 NF1252-6PB6A NF2002-3MB8B 2,860 3,710 400 600 NF400P-3MB4B NF600P-3MB4B 12,360 20,360 NF4002-3MB4B NF6002-3MB4B 6,030 10,420 800 1200 NF800P-3MB4A NF1200P-3MB4A 32,360 38,360 NF8002-3MB4A NF12002-3MB4A 19,860 24,020 UL 98 UL508 18 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule H2E [DB]: Non-fusible, 125A - 800A Discount schedule H3E [DC]: Non-fusible, 1200A - 3150A 18.51 1SXU000023C0202 ct ne s n o he e l sc Di witc usib s -f ed s n No nclo E Accessories 1 Auxiliary contacts Catalog number Installation suffix Installed list price adder 1 N.O. 1 N.C. 1 N.O. & 1 N.C. OA1G10 OA1G01 OA2G11 add "10" suffix add "01" suffix add "11" suffix $ 30 30 60 125A 1 N.O. 1 N.C. OBEA-10 OBEA-01 add "10" suffix add "01" suffix 50 50 200A - 600A 1 N.O. 1 N.C. OA1G10 OA3G01 add "10" suffix add "01" suffix 30 30 1 N.O. & 1 N.C. 2 N.O. & 2 N.C. OZXK-1 OZXK-2 add "11" suffix add "22" suffix 130 200 For use on: 16A - 100A OA1G_ 800A - 3150A Contact configuration Accessories 1 OBEA_ For use on: Description Installation suffix Installed list price adder OT16, 25,32 OT45, 63 OT30, 60, 100 OT160 200A - 1200A 1600A - 3150A Neutral or isolated ground block Neutral or isolated ground block Neutral or isolated ground block Neutral or isolated ground block Neutral block Neutral block N or G N or G N or G N or G N N $ 30 54 75 150 210 350 U V 100 200 A C D E AM VM 68 68 78 110 940 2300 30A - 1200A 30A - 1200A 16A - 3150A Service entrance, 3 wire Service entrance, 4 wire Start/stop pushbuttons 2 position selector switch 3 position selector switch Pilot light "red/run" Ammeter 1 phase 2 Voltmeter 2 OZXK_ 3 Position selector switch 18 Pilot light 1 Please consult factory for special customer requirements. 2 Current transformers included. 18.52 1SXU000023C0202 Discount schedule H1E [DA]: Non-fusible, 16A - 100A Discount schedule H2E [DB]: Non-fusible, 125A - 800A Discount schedule H3E [DC]: Non-fusible, 1200A - 3150A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con n i Fu tch ect e s En ib s clo le se d 3 Pole 30A - 800A FJ30X-3PB6B 3 Pole, 600V, 30A - 800A 1 NEMA Enclosure type 1 3R 4 UL Fuse UL 98 general purpose type amp rating Catalog number List price $ 560 30 30 J CC FJ301-3PB6B FC301-3PB6B 60 100 J2 J2 FJ601-3PB6B FJ1001-3PB8B 200 400 J2 J2 600 800 J2 L Catalog number List price Catalog number 4X Stainless List price Catalog number List price FJ303-3PB6B FC303-3PB6B $ 600 FJ304-3PB6B $ 1,100 FC304-3PB6B FJ30X-3PB6B FC30X-3PB6B 660 960 FJ603-3PB6B FJ1003-3PB8B 860 1,140 FJ604-3PB8B FJ1004-3PB8B 1,300 2,800 FJ60X-3PB8B FJ100X-3PB8B 1,800 3,800 FJ2001-3PB8C FJ4001-3PB4C 2,200 3,800 FJ2003-3PB8C FJ4003-3PB4C 2,400 4,200 FJ2004-3PB8C FJ4004-3PB4C 3,900 7,700 FJ200X-3PB8C FJ400X-3PB4B 5,000 10,800 FJ6001-3PB7C FL8001-3PB4B 5,300 9,500 FJ6003-3PB7C FL8003-3PB4B 6,800 11,200 FJ6004-3PB7C FL8004-3PB4B 11,000 16,000 FJ600X-3PB7C FL800X-3PB4B 16,000 21,000 $ 1,400 3 Pole, 600V, 30A - 800A 1 NEMA Enclosure type 4X Plastic Fuse general purpose type amp rating UL 98 UL 12 Catalog number List price Catalog number List price $ 1,040 FJ302-3PB6B FC302-3PB6B $ 600 30 30 J CC FJ30P-3PB6B FC30P-3PB6B 60 100 J2 J2 FJ60P-3PB8B FJ100P-3PB8B 1,300 2,800 FJ602-3PB6B FJ1002-3PB8B 860 1,140 200 400 J2 J2 FJ200P-3PB8C FJ400P-3PB4C 4,400 8,400 FJ2002-3PB8C FJ4002-3PB4C 2,400 4,200 600 800 J2 L FJ600P-3PB7C FL800P-3PB4B 13,600 17,400 FJ6002-3PB7C FL8002-3PB4B 6,200 9,800 NOTE: All enclosed switches are provided with a black handle; however, most handles can be substituted with a red / yellow handle if desired. Please substitute the handle suffix code (2nd and 3rd from last characters) with the red/yellow handle catalog number suffix from page 18.130. There is no additional price adder for changing to a red/yellow handle of equal ratings and style. EXAMPLE: A red/yellow pistol handle for an FJ301-3PB6B can be substituted for the black pistol handle by using the "Y6" suffix instead of the "B6" suffix, new catalog number: FJ3013PY6B. 18 1 Fusible switches are UL listed to the UL98 standard. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule H4E: Fusible, 30A - 100A Discount schedule H5E: Fusible, 200A - 3150A 18.53 1SXU000023C0202 ct ne s n o he sc Di witc ible s us ed F los c En 2 & 4 Pole 30A - 800A 2 Pole, 600V, 30A - 800A 1 3R NEMA Enclosure type 4 UL general purpose amp rating Fuse type List price Catalog number List price Catalog number List price Catalog number -- -- -- -- -- FJ1001-2PB8B -- $ 864 -- FJ1003-2PB8B $ 1,026 -- FJ1004-2PB8B -- $ 2,735 -- FJ100X-2PB8B -- $ 3,420 J J FJ2001-2PB8C FJ4001-2PB4C 1,980 3,420 FJ2003-2PB8C FJ4003-2PB4C 2,160 3,780 FJ2004-2PB8C FJ4004-2PB4C 3,600 7,775 FJ200X-2PB8C FJ400X-2PB4C 4,500 9,720 J L FJ6001-2PB7C FL8001-2PB4B 4,770 8,550 FJ6003-2PB7C FL8003-2PB4B 6,120 10,080 FJ6004-2PB7C FL8004-2PB4B 11,520 15,120 FJ600X-2PB7C FL800X-2PB4B 14,400 18,900 30 30 J CC 60 100 J J 200 400 600 800 -- -- -- -- List price -- -- UL 98 Catalog number 4X Stainless -- -- -- -- NEMA Enclosure type 4X Plastic 12 UL general purpose amp rating Fuse type Catalog number List price -- -- List price -- -- 30 30 J CC 60 100 J J -- FJ100P-2PB8B -- $ 2,520 -- FJ1002-2PB8B -- $ 1,026 200 400 J J FJ200P-2PB8C FJ400P-2PB4C 3,960 7,560 FJ2002-2PB8C FJ4002-2PB4C 2,160 3,780 600 800 J L FJ600P-2PB7C FL800P-2PB4B 12,240 15,660 FJ6002-2PB7C FL8002-2PB4B 5,580 8,820 UL 98 -- -- Catalog number -- -- 4 Pole, 600V, 30A - 800A 1 3R NEMA Enclosure type 4 UL general purpose amp rating Catalog number List price List price FJ303-4PB6B $ 750 FC303-4PB6B Catalog number List price Catalog number J CC 60 100 J J FJ601-4PB6B FJ1001-4PB8B 825 1,200 FJ603-4PB6B FJ1003-4PB8B 1,075 1,425 FJ604-4PB8B FJ1004-4PB8B 1,800 3,800 FJ60X-4PB8B FJ100X-4PB8B 2,250 4,750 200 400 J J FJ2001-4PB8C FJ4001-4PB4C 2,750 4,750 FJ2003-4PB8C FJ4003-4PB4C 3,000 5,250 FJ2004-4PB8C FJ4004-4PB4C 5,000 10,800 FJ200X-4PB8C FJ400X-4PB4C 6,250 13,500 600 800 J L FJ6001-4PB7C FL8001-4PB4B 6,625 11,875 FJ6003-4PB7C FL8003-4PB4B 8,500 14,000 FJ6004-4PB7C FL8004-4PB4B 16,000 21,000 FJ600X-4PB7C FL800X-4PB4B 20,000 26,250 NEMA Enclosure type 4X Plastic 12 UL general purpose amp rating Fuse type Catalog number 30 30 J CC 60 100 J J FJ60P-4PB8B FJ100P-4PB8B 200 400 J J 600 800 J L 18.54 1SXU000023C0202 List price FJ30P-4PB6B $ 1,300 FC30P-4PB6B Catalog number FJ304-4PB6B $ 1,375 FC304-4PB6B FJ30X-4PB6B FC30X-4PB6B List price 30 30 UL 98 FJ301-4PB6B $ 700 FC301-4PB6B Catalog number UL 98 18 Fuse type 4X Stainless $ 1,750 List price FJ302-4PB6B FC302-4PB6B $ 750 1,625 3,500 FJ602-4PB6B FJ1002-4PB8B 1,075 1,425 FJ200P-4PB8C FJ400P-4PB4C 5,500 10,500 FJ2002-4PB8C FJ4002-4PB4C 3,000 5,250 FJ600P-4PB7C FL800P-4PB4B 17,000 21,750 FJ6002-4PB7C FL8002-4PB4B 7,750 12,250 Discount schedule H4E: Fusible, 30A - 100A Discount schedule H5E: Fusible, 200A - 3150A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con n i Fu tch ect e s En ib s clo le se d Accessories 12 Auxiliary contacts Contact Catalog Installation For use on: configuration number suffix 30A 60A - 600A 800A 1 N.O. + 1 N. C. OA4B1C 2 N.O. + 2 N.C. Installed list price adder add "11" suffix add "22" suffix $ 40 40 1 N.O. 1 N.C. OA1G10 OA3G01 add "10" suffix add "01" suffix 20 1 N.O. & 1 N.C. 2 N.O. & 2 N.C. OZXK-1 OZXK-2 add "11" suffix add "22" suffix 100 170 OESA-ZX157 Accessories 12 Installation For use on: Description suffix OZXK-1 OZXK-2 Installed list price adder 30A 60A - 100A 200A - 400A 600A - 800A Neutral block Neutral block Neutral block Neutral block N N N N $ 40 50 150 160 30A - 200A Service entrance, 3 wire Service entrance, 4 wire U V 75 125 400A - 800A Service entrance, 3 wire Service entrance, 4 wire U V 150 200 30A - 800A Start/stop pushbuttons 2 position selector switch 3 position selector switch Pilot light "red/run" Ammeter 1 phase 3 Voltmeter 3 A C D E AM VM 68 68 78 110 940 2300 3 Position selection switch Pilot light 18 1 Additional accessories can be found on pages 18.83 - 18.95. 2 Please consult factory for special customer requirements. 3 Current transformers included. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Discount schedule H4E: Fusible 30A - 100A Discount schedule H5E: Fusible, 200A - 3150A 18.55 1SXU000023C0202 ct ne s n o he sc Di witc ible s us ed F los c En Notes 18 18.56 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Technical data Approximate dimensions Di s sw con Te itch nec ch e t da nica s ta l Selecting switches per NEC Selecting switches per NEC Article 430 of the US National Electric Code includes two methods for properly sizing disconnect switches: 1. Single motor application 2. Combination load application A properly sized disconnect switch for a single motor will: A properly sized disconnect switch for a combination load will be selected by adding all the simultaneous individual loads in the circuit under consideration. a) have an ampere rating greater than or equal to 115 percent of the rated motor full load current; or, b) have a HP rating greater than or equal to the rated motor HP (at applied voltage) if the disconnect switch under consideration is HP rated. Using motor nameplate information, load information, and tables from section 430 of the NEC, determine one equivalent full load current and one equivalent locked rotor current. The equivalent locked rotor current can be used with table 430151 to determine an equivalent HP rating. Select a disconnect switch: a) greater than or equal to 115 percent of the equivalent full load current; and, b) greater than or equal to the equivalent HP rating. Use of UL98 & UL508 Disconnects According to NEC (R) Article 430 To supply UL98 Feeder Circuit UL98 Motor feeder Non-Fusible Switches OT30, OT60 OT100 OT200, OT400, OT600 OETL-NF800 thru OETL-NF2000 Motor feeder short circuit and ground fault protection UL98 Fusible Switches OS30, OS60, OS100, OS200, OS400, OS600 OES800 Motor disconnecting means (NEC (R) 430.101 - 430.113) 18 Motor branch-circuit short-circuit protection Typical control panel (NEC (R) 430.51 - 430.58) Motor controller Branch Circuit UL508 (NEC (R) 430.81 - 4.30.91) Motor overload protection OSHA Lockout/tagout disconnect (NEC (R) 430.81 - 430.91) Motor Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage OL (NEC (R) 430.31 - 4.30.44) UL508 Non-Fusible Switches OT16, OT25, OT40, OT63, OT80 (UL98 switches can also be applied) M 18.57 1SXU000023C0202 ct ne s n o he l sc Di witc nica s ch a Te dat Technical data OT16F3 - OT100F3 UL & CSA UL & CSA Catalog number 3 pole Approvals1 2 pole 3 pole 4 pole OT16F3 OT25F3 OT40F3 OT63F3 OT80F3 OT30F3 OT60F3 OT100F3 N/A UL508 & IEC UL508 & IEC N/A UL508 & IEC UL508 & IEC N/A UL508 & IEC UL508 & IEC N/A UL508 & IEC UL508 & IEC N/A UL508 & IEC UL508 & IEC N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC -40 to 40C General purpose amp rating pf = 0.7 - 0.8 A 20 30 40 60 80 30 60 100 Max. operating voltage V 600 600 600 600 600 600 600 600 Max. horsepower rating/motor FLA current, pf = 0.4 - 0.5 Three phase 240V HP/A 5/15.2 7.5/22.0 10/28.0 15/42.0 20/54.0 10/28.0 20/54.0 30/80.0 480V HP/A 10/14.0 15/21.0 20/27.0 30/40.0 40/52.0 20/27.0 40/52.0 50/65.0 600V HP/A 10/11.0 20/22.0 25/27.0 30/32.0 40/41.0 30/32.0 40/41.0 50/52.0 120V HP/A 1/16 1.5/20 3/24 2/24.0 2/24.0 2/24.0 3/34.0 5/56.0 240V HP/A 2/13.2 3/18.7 5/30.8 7.5/40.0 10/57.5 5/28.0 7.5/40.0 15/68.0 Single phase Short circuit rating with fuse Fuse type CC kA 10 -- 10 --- 10 --- -- -- -- -- -- -- -- -- -- -- Fuse type J kA 10 10 10 10 10 10 100 -- 100 -- 50 -- 50 -- 50 -- Fuse type T kA 10 10 10 10 10 10 100 -- 100 -- 50 -- 50 -- 50 -- Fuse type RK1 kA 10 -- 10 -- 10 -- -- -- -- -- -- -- -- -- -- -- Fuse type RK5 kA 5 5 5 5 5 5 10 5 10 5 -- -- -- -- -- -- Fuse type L kA -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Fuse type H kA -- -- -- -- -- -- -- 5 -- 5 -- -- -- -- -- -- A 30 60 4 30 60 4 30 60 4 100 150 100 150 60 -- 150 -- 150 -- Maximum fuse size 3 cycle short circuit current withstand rating 5 kA -- -- Min. Electrical endurance, pf = 0.75 - 0.80 operation cycles 6000 6000 Min. Electrical endurance, pf = 0.40 - 0.50 operation cycles 1000 20,000 -- -- -- -- -- -- 6000 6000 6000 6000 6000 6000 1000 1000 1000 1000 2 2 2 20,000 20,000 20,000 20,000 20,000 20,000 20,000 Endurances Mechanical endurance operations Physical characteristics Weight, switches 3 pole lb 0.24 0.24 0.24 0.59 0.59 0.79 0.79 0.79 4 pole 0.33 0.33 0.33 0.77 0.77 1.10 1.10 1.10 Dimension, switches 3 pole lb H in 2.68 2.68 2.68 3.60 3.60 3.94 3.94 3.94 W in 1.38 1.38 1.38 2.07 2.07 2.76 2.76 2.76 D in 2.20 2.20 2.20 2.85 2.85 2.95 2.95 2.95 lb. in. 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 .24 x .24 .24 x .24 .24 x .24 .24 x .24 .24 x .24 .24 x .24 .24 x .24 .24 x .24 6x6 6x6 6x6 6x6 6x6 6x6 6x6 6x6 8.8 8.8 8.8 10.5 10.5 17.5 17.5 17.5 Shaft set screw tightening torque Shaft size -- square Switch operating torque for rotary 3 pole switches in mm lb. in. Terminal lug kits Wire range AWG Not required Not required Not required Not required Not required Not required Not required Not required #18 - 8 #18 - 8 #18 - 8 #14 - 4 #14 - 4 #14 - 4 #14 - 4 #8 - 1/0 Torque: Wire tightening lb. in. 7 7 7 18 18 55 55 55 Lug mounting lb. in. Integral Integral Integral Integral Integral Integral Integral Integral Auxiliary contacts OA1G_ _ OA1G_ _ OA1G_ _ OA1G_ _ OA1G_ _ OA1G_ _ OA1G_ _ OA1G_ _ NEMA ratings, AC A600 A600 A600 A600 A600 A600 A600 A600 VAC 600 600 600 600 600 600 600 600 A 10 10 10 10 10 10 10 10 AC maximum volt-ampere making VA 7200 7200 7200 7200 7200 7200 7200 7200 AC maximum volt-ampere breaking VA 18 AC rated voltage AC thermal rated current NEMA ratings, DC DC rated voltage DC thermal rated current DC maximum make-break Torque: Wire tightening Wire range 1 2 3 4 5 VDC 720 720 720 720 720 720 720 720 R300 R300 R300 R300 R300 R300 R300 R300 300 300 300 300 300 300 300 300 A 1 1 1 1 1 1 1 1 VA 28 28 28 28 28 28 28 28 7 #18 - 14 7 #18 - 14 7 #18 - 14 7 #18 - 14 7 #18 - 14 7 #18 - 14 7 #18 - 14 7 #18 - 14 lb. in AWG UL Listed switches are also CSA Approved. UL98 overload test, 50 operations, pf 0.40 - 0.50 at 2x FLA. Multi-tap lug available, please see pg. 18.24 and 18.27. Fuse size 70A for RK5 When protected by any Listed fuse or Listed circuit breaker whose current rating does not exceed the maximum thermal current rating of the switch. 18.58 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Te itch nec ch e t da nica s ta l Technical data OT200U03 - OETL-NF3150 UL & CSA UL & CSA Catalog number 3 pole OT200U03 Approvals1 2 pole 3 pole 4 pole General purpose amp rating UL98 & IEC UL98 & IEC UL98 & IEC -40 to 40C pf = 0.7 - 0.8 Max. operating voltage OT400U03 OT600U03 OETL-NF800A OETL-NF1200 OETL-NF1600 UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC IEC UL98 & IEC UL98 & IEC IEC UL98 & IEC UL98 & IEC IEC OETL-NF2000 UL98 & IEC UL98 & IEC IEC OETL-NF31505 IEC IEC IEC A 200 400 600 800 1200 1600 2000 3150 V 600 600 600 600 600 600 480 -- Max. horsepower rating/Max. motor FLA current, pf = 0.4 - 0.5 Three phase 240V HP/A 75/192.0 125/312.0 200/480.0 250/602.0 -- -- -- -- 480V HP/A 150/180.0 250/302.0 450/515 500/590.0 -- -- -- -- 600V HP/A 200/192.0 350/336.0 500/472.0 600/576 -- -- -- -- 120V HP/A -- -- -- -- -- -- -- -- 240V HP/A -- -- -- -- -- -- -- -- Single phase Short circuit rating with fuse Fuse type CC kA -- -- -- -- -- -- -- -- Fuse type J kA 100 100 --/100 -- -- -- -- -- Fuse type T kA -- -- 100/-- -- -- -- -- -- Fuse type RK1 kA -- -- -- -- -- -- -- -- Fuse type RK5 kA -- -- 100 -- -- -- -- -- Fuse type L kA -- -- --/100 100 100 100 100 -- Fuse type H kA -- -- --/100 -- -- -- -- -- Maximum fuse size A 350 600 600/800 1200 1200 2000 2000 -- 15 30 50 50 50 65 65 -- 6000 1000 1000 500 500 500 500 400 3 cycle short circuit current withstand rating 6 kA Endurances Min. Electrical endurance, pf = 0.75 - 0.80 operation cycles Min. Electrical endurance, pf = 0.40 - 0.50 operation cycles 2 2 2 2 2 2 2 2 20,000 20,000 10,000 10,000 10,000 6000 6000 6000 3 pole lb 2.9 5.7 11.4 35.9 38.55 127.7 127.7 127.7 4 pole lb 3.5 6.8 14.3 45.15 49.56 149.7 149.7 149.7 Mechanical endurance operations Physical characteristics Weight, switches Dimension, switches 3 pole H in 6.69 8.66 9.84 14.65 14.65 21.5 21.5 21.5 W in 6.67 8.70 10.48 14.25 14.25 18.11 18.11 18.11 D in 10.67 Shaft set screw tightening torque 3.27 4.15 5.47 4.92 4.92 10.67 10.67 lb. in. 14 - 17.7 -- -- -- -- -- -- -- in .24 x .24 .47 x .47 .47 x .47 .47 x .47 .47 x .47 .47 x .47 .47 x .47 .47 x .47 6x6 12 x 12 12 x 12 12 x 12 12 x 12 12 x 12 12 x 12 12 x 12 Shaft size -- square Switch operating torque for rotary 3 pole switches mm lb. in. 62 142 184 184 184 438 438 438 OZXA-200 OZXA-400 OZXA-800 OZXA-30 OZXA-28 OZXA-28 OZXA-28/2 OZXA-28/2 AWG #4-300kcmil3 #2-600kcmil3 (4)#2-600kcmil (4)#2-600kcmil (8)#2-600kcmil (8)#2-600kcmil 375 Terminal lug kits Wire range (2)#2-600kcmil3 (2)#2-600kcmil3 Torque: Wire tightening lb. in. 200 375 375 375 375 375 375 Lug mounting lb. in. 72 240 240 230 230 230 230 230 Auxiliary contacts OA_G_ OA_G_ OA_G_ OZXK-_ _ OZXK-_ _ OZXK-_ _ OZXK-_ _ OZXK-_ _ NEMA ratings, AC A600 A600 A600 A600 A600 A600 A600 A600 VAC 600 600 600 600 600 600 600 600 A 10 10 10 10 10 10 10 10 AC maximum volt-ampere making VA 7200 7200 7200 7200 7200 7200 7200 7200 AC maximum volt-ampere breaking VA AC rated voltage AC thermal rated current NEMA ratings, DC DC rated voltage VDC DC thermal rated current DC maximum make-break Torque: Wire tightening Wire range 1 2 3 4 5 6 720 720 720 720 720 720 720 720 P600 P600 P600 P600 P600 P600 P600 P600 600 600 600 600 600 600 600 600 A 5 5 5 5 5 5 5 5 VA 138 138 138 138 138 138 138 138 7 #22 - #14 7 #22 - #14 7 #22 - #14 7 #22 - #14 7 #22 - #14 7 #22 - #14 7 #22 - #14 7 #22 - #14 lb. in AWG UL Listed switches are also CSA Approved. UL98 overload test, 50 operations, pf 0.40 - 0.50 at 2x FLA. Multi-tap lug available, please see pg. 18.24 and 18.27. Fuse size 70A for RK5 IEC rated only. When protected by any Listed fuse or Listed circuit breaker whose current rating does not exceed the maximum thermal current rating of the switch. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.59 1SXU000023C0202 18 ct ne s n o he l sc Di witc nica s ch a Te dat Technical data OT16F3 - OT100F3 IEC IEC Catalog number 3 pole Rated insulation and operation voltage, AC20 and DC20 Rated impulse withstand voltage OT16F3 OT25F3 OT40F3 OT63F3 V 750 750 750 750 kV 8 8 8 8 OT80F3 OT30F3 OT60F3 OT100F3 750 750 750 750 8 8 8 8 40C Rated thermal current, Ith AC 20/DC 20 open 1 A 25 32 40 63 80 40 63 115 40C enclosed A 25 32 40 63 80 40 63 115 60C enclosed A 25 32 40 63 80 40 63 115 500V A 16 25 40 63 80 30 60 100 690V A 16 25 40 63 80 40 63 100 1000V A -- -- -- -- -- -- -- -- AC 22A 500V A 16 25 40 63 80 40 63 100 690V A 16 25 40 63 80 40 63 100 1000V A -- -- -- -- -- -- -- -- AC 23A 415V A 16 20 23 45 75 40 63 80 Rated operational currents AC 21A 500V A 16 20 23 45 58 40 60 60 690V A 10 11 12 20 20 40 40 40 1000V A -- -- -- -- -- -- -- -- 48V A 16/1 25/1 32/1 45/1 63/1 40/1 63/1 100/1 110V A 16/2 25/2 32/2 45/2 63/2 40/2 63/2 100/2 220V A 16/3 25/3 32/3 45/4 63/4 40/4 63/4 100/4 440V A 16/4 25/6 32/6 3 3 3 3 3 750V A 16/8 25/8 32/8 3 3 3 3 3 48V A 16/1 25/1 32/1 45/1 63/1 40/1 63/1 100/1 110V A 16/2 25/2 32/2 45/2 63/2 40/2 63/2 100/2 220V A 16/3 25/3 32/4 45/4 63/4 40/4 63/4 63/4 440V A 16/6 25/8 3 3 3 3 3 3 750V A 16/8 25/8 3 3 3 3 3 3 48V A 16/1 25/1 32/1 45/1 63/1 40/1 63/1 100/1 110V A 16/2 25/2 32/2 45/2 63/2 40/2 63/2 100/2 220V A 16/4 25/4 32/4 45/4 63/4 40/4 63/4 63/4 440V A 10/4 3 3 3 3 3 3 3 750V A 16/8 3 3 3 3 3 3 3 Rated operational currents/poles in series DC21A DC22A DC23A Rated operational power AC23A Short-circuit current with back-up fuses of size 230V kW 3 4 5.5 11 22 7.5 11 22 400/415V kW 7.5 9 11 22 37 15 18.5 37 500V kW 7.5 9 11 22 37 15 18.5 37 690V kW 7.5 9 11 15 18.5 15 15 37 kA 50 50 50 50 50 50 50 50 A 25 32 40 63 80 100 100 100 18 Load Load Load 2 poles in series 3 poles in series 4 poles in series 1 The ambient air temperature does not exceed +40C and its average over a period of 24 hours does not exceed +35C according to IEC 947. 2 IEC 947-3, utilization category B, infrequent operation. 3 Not available at time of printing, please consult factory. 18.60 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Te itch nec ch e t da nica s ta l Technical data OT200U03 - OETL-NF3150 IEC IEC Catalog number 3 pole Rated insulation and operational OT200U03 OT400U03 OT600U03 OETL-NF800A OETL-NF1200 OETL-NF1600 OETL-NF2000 OETL-NF3150 V 1000 1000 1000 1000 1000 1000 1000 1000 kV 12 12 12 8 8 8 8 8 40C voltage, AC20 and DC20 Rated impulse withstand voltage Rated thermal current, Ith AC 20/DC 20 open1 A 250 400 800 1250 1600 2500 3150 40C enclosed A 250 400 800 1250 1600 2300 2300 2600 60C enclosed A -- -- -- 1000 1250 1950 1950 2300 Rated operational currents AC 21A 500V A 250 400 800 1250 1600 25002 25002 31502 690V A 250 400 800 1250 1600 25002 25002 31502 1000V A -- -- 800 -- -- -- AC 22A 500V A 250 400 800 1250 1600 16002 16002 16002 690V A 250 400 800 -- -- -- -- -- 1000V A -- -- 800 -- -- -- -- -- AC 23A 415V A 250 400 800 800 800 8002 8002 8002 500V A 250 400 800 800 800 8002 8002 8002 690V A 250 400 800 -- -- -- -- -- 1000V A -- -- 800 -- -- -- -- -- ---- Rated operational currents/poles in series DC21A 48V A 250/1 630/2 800/2 1250/2 1600/2 2500/2 2500/2 3150/2 110V A 250/2 630/2 800/2 1250/2 1600/2 2500/2 2500/2 3150/2 220V A 250/2 630/2 800/2 1250/2 1600/2 2500/2 2500/2 3150/2 440V A 250/3 630/3 800/3 1250/3 1600/3 2500/3 2500/3 3150/2 750V A 250/4 -- -- -- -- -- -- -- DC22A 48V A 250/1 630/2 800/2 1250/2 1600/2 2500/2 2500/2 3150/2 110V A 250/2 630/2 800/2 1250/2 1600/2 2500/2 2500/2 3150/2 220V A 250/2 630/2 800/2 1250/2 1600/2 2500/2 2500/2 3150/2 440V A 250/3 630/3 800/3 -- -- -- -- -- 750V A 250/4 -- -- -- -- -- -- -- DC23A 48V A 250/1 630/2 -- -- -- -- -- -- 110V A 250/2 630/2 -- -- -- -- -- -- 220V A 250/2 630/2 -- -- -- -- -- -- 440V A 250/3 -- -- -- -- -- -- -- 750V A 250/4 -- -- -- -- -- -- -- Rated operational power AC23A 230V kW 75 110 -- 250 250 250 250 250 400/415V kW 132/140 220/230 450 400 400 400 400 400 500V kW 170 280 560 450 450 450 450 450 690V kW 240 355 800 -- -- -- -- -- Short-circuit current kA 100 100 100 50/504 50/504 50/634 50/634 50/634 with back-up fuses of size A 400 800 800 -- -- -- -- -- 18 Load Load Load 2 poles in series 3 poles in series 4 poles in series 1 The ambient air temperature does not exceed +40C and its average over a period of 24 hours does not exceed +35C according to IEC 947. 2 IEC 947-3, utilization category B, infrequent operation. 3 Not available at time of printing, please consult factory. 4 690V / 500V Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.61 1SXU000023C0202 ct ne s n o he l sc Di witc nica s ch a Te dat Technical data OT16F3 - OT100F3 IEC IEC Catalog number 3 pole Rated short-circuit making capacity, prospective peak value, Icm kA OT16F3 OT25F3 0.7 0.7 OT40F3 OT63F3 OT80F3 OT30F3 0.7 1.4 1.4 3.6 OT60F3 3.6 OT100F3 3.6 Rated short time withstand current, RMS lcw 0.2s kA -- -- -- -- -- -- -- -- RMS lcw kA 0.5 0.5 0.5 1 1 2.5 2.5 2.5 1.0s AC breaking capacity pf = 0.35 415V A 128 160 184 240 304 320 504 640 500V A 128 160 184 240 256 320 480 480 690V A 80 88 96 160 160 320 320 320 48V A 64/1 100/1 128/1 180/1 252/1 160/1 252/1 400/1 110V A 64/2 100/2 128/2 180/2 252/2 160/2 252/2 400/2 220V A 64/3 100/4 128/4 180/4 180/4 160/4 252/4 252/4 440V A 1 1 1 1 1 1 1 1 750V A 1 1 1 1 1 1 1 1 DC breaking capacity/poles in series L/R = 15ms Physical characteristics Electrical endurance at rated operational current, pf = 0.65 operation cycles Mechanical endurance Weight Dimension operations 3000 3000 3000 3000 3000 3000 3000 20,000 20,000 20,000 20,000 20,000 20,000 20,000 0.36 3 pole kg 0.11 0.11 0.11 0.27 0.27 0.36 0.36 4 pole kg 0.15 0.15 0.15 0.35 0.35 0.5 0.5 0.5 3 pole H mm 68 68 68 91.5 91.5 100 100 100 W mm 35 35 35 52.5 52.5 70 70 70 D mm 56 56 56 72.5 72.5 75 75 75 W 0.3 0.6 1 1.4 2.8 1 1.6 4 6x6 6x6 6x6 6x6 6x6 6x6 6x6 6x6 Power loss per pole Shaft size -- square 3000 20,000 mm Switch operating torque for rotary 3 pole switches 1 1 1 1.2 1.2 2 2 2 mm2 0.75 - 10 0.75 - 10 0.75 - 10 1.5 - 25 1.5 - 25 1.5 - 25 1.5 - 25 10 - 70 -- -- -- Auxiliary contacts OA1G_ _ OA1G_ _ OA1G_ _ OA1G_ _ OA1G_ _ OA1G_ _ OA1G_ _ OA1G_ _ VAC 690 690 690 690 690 690 690 690 A 16 16 16 16 16 16 16 16 A -- -- -- -- -- -- -- -- 125V A -- -- -- -- -- -- -- -- 240V A 62 62 62 62 62 62 62 62 250V A -- -- -- -- -- -- -- -- 400V A 42 42 42 42 42 42 42 42 Suitable conductor cross section Cu Nm Bolt size Ratings according to IEC 947-5-1 Rated voltage, Ui Thermal current, Ith AC12/DC12 Ie, A Ue =120V 18 -- -- -- -- -- 415V A -- -- -- -- -- -- -- -- 440V A -- -- -- -- -- -- -- -- 480V A -- -- -- -- -- -- -- -- 500V A -- -- -- -- -- -- -- -- 600V A -- -- -- -- -- -- -- -- 690V A 22 22 22 22 22 22 22 22 Load Load Load 2 poles in series 3 poles in series 4 poles in series 1 Not available at time of printing, please consult factory. 2 AC15, according to IEC947-5-1. 18.62 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Te itch nec ch e t da nica s ta l Technical data OT200U03 - OETL-NF3150 IEC IEC Catalog number 3 pole OT200U03 OT400U03 OT600U03 OETL-NF800A OETL-NF1200 OETL-NF1600 OETL-NF2000 65 80 105 105 140/105 140/105 OETL-NF3150 Rated short-circuit making capacity, prospective peak value, Icm500/690V kA 30 140/105 Rated short time withstand current, RMS lcw 0.2s kA 15 28 36 -- -- -- -- -- RMS lcw 1.0s kA 8 15 20 50 2 50 2 80 2 80 2 80 2 6400 AC breaking capacity 415V A 2000 3200 5760 6400 6400 6400 6400 pf = 0.35 500V A 2000 3200 5600 6400 6400 6400 6400 6400 690V A 2000 3200 5600 2500 3 2500 3 4800 4 4800 4 4800 4 1 DC breaking capacity/poles in series L/R = 15ms, 3 pole in series 48V A 1000/2 1 1 1 1 1 1 110V A 1000/2 1 1 1 1 1 1 1 220V A 1000/2 1600/2 2000/2 1900/2 2600/2 2600/2 2600/2 2600/2 440V A 1000/3 1600 2000/3 1 1 1 1 1 750V A 1000/4 1 1 1 1 1 1 1 Physical characteristics Electrical endurance at rated operational current, pf = 0.65 operation cycles Mechanical endurance operations 1000 1000 1000 500 500 100 5 100 5 100 5 20,000 16,000 10,000 10,000 10,000 6000 6000 6000 37 Weight 3 pole kg 1.2 2.2 5.2 16.3 17.5 37 37 4 pole kg 1.6 2.6 6.5 20.5 22.5 47 47 47 Dimension 3 pole H mm 162 216 250 372 372 546 546 546 W mm 219 260 266 363 363 468 468 468 D mm 92.5 130 139 125 125 271 271 271 Power loss per one pole W 6.5 10 40 40 67 90 90 140 mm 6x6 12 x 12 12 x 12 12 x 12 12 x 12 12 x 12 12 x 12 12 x 12 50 Shaft size -- square Switch operating torque for rotary 3 pole switches Nm 7 16 21 21 21 50 50 Suitable conductor cross section Cu mm2 -- -- -- -- -- -- -- -- Bolt size 8 x 25 10 x 30 12 x 40 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 Auxiliary contacts OA_G_ OA_G_ OA_G_ OZXK-_ _ OZXK-_ _ OZXK-_ _ OZXK-_ _ OZXK-_ _ 690 Ratings according to IEC 947-5-1 Rated voltage, Ui VAC 690 690 690 690 690 690 690 Thermal rated current, Ith A 16 16 10 10 10 10 10 10 AC12/DC12 Ie, A Ue = 120V A -- -- 8/-- 8/-- 8/-- 8/-- 8/-- 8/-- 125V A -- -- --/1.1 --/1.1 --/1.1 --/1.1 --/1.1 --/1.1 240V A 6/-- 6/-- 6/-- 6/-- 6/-- 6/-- 6/-- 6/-- 250V A -- -- --/0.55 --/0.55 --/0.55 --/0.55 --/0.55 --/0.55 400V A 4/-- 4/-- 4/-- 4/-- 4/-- 4/-- 4/-- 4/-- 415V A -- -- 4/-- 4/-- 4/-- 4/-- 4/-- 4/-- 440V A -- -- --/0.31 --/0.31 --/0.31 --/0.31 --/0.31 --/0.31 480V A -- -- 3/-- 3/-- 3/-- 3/-- 3/-- 3/-- 500V A -- -- 3/0.27 3/0.27 3/0.27 3/0.27 3/0.27 3/0.27 600V A -- -- --/0.2 --/0.2 --/0.2 --/0.2 --/0. 2--/0.2 690V A 2/-- 2/-- 2/-- 2/-- 2/-- 2/-- 2/-- 2/-- 1 2 3 4 5 Load Load Load 2 poles in series 3 poles in series 4 poles in series Not available at time of printing, please consult factory. Maximum distance between busbar support and switch terminal 70mm. pf 0.95. pf 0.65. IEC 947-3, utilization category B, infrequent operation. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.63 1SXU000023C0202 18 ct ne s n o he l sc Di witc nica s ch a Te dat Technical data OS30FA_12 - OES800L3 UL & CSA UL & CSA Catalog number 3 pole Approvals 1 2 pole 3 pole 4 pole Technical ratings OS30FA_12 OS60J12 OS100J03 OS200J03 OS400J03 OS600J03 OES800L3 N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC A 30 60 100 200 400 600 800 V 600 600 600 600 600 600 600 -40 to 40C General purpose amp rating pf = 0.7 - 0.8 Max operating voltage Max horsepower rating/ Max motor FLA current pf = 0.4 - 0.5 Three phase 240V Hp/A 480V Hp/A 600V Hp/A Single phase 120V 240V 7.5/22.0 15/42.0 30/80.0 60/145.0 125/312.0 200/480.0 15/21.0 30/40.0 60/77.0 125/156.0 250/302.0 400/477.0 20/22.0 50/52.0 75/77.0 150/144.0 350/336.0 500/472.0 250/602.0 500/590.0 600/ -- Hp/A Hp/A 2/24.0 3/17.0 -- -- -- -- -- -- -- -- -- -- -- -- Short circuit rating with fuse kA UL Fuse size A UL Fuse type 200 30 J/CC 200 60 J 200 100 J/T 200 200 J/T 200 400 J 200 600 J 100 800 L Endurances Min. Electrical endurance, pf = 0.75 - 0.80 operation cycles 6000 6000 6000 6000 1000 1000 500 operation 20,000 20,000 20,000 20,000 12,000 10,000 7000 Weight 3 pole lb 4 pole lb 1.54 1.98 2.86 3.52 3.30 3.96 5.9 7.5 12.56 15.21 28.66 37.48 37.44 46.26 Dimension 3 pole H in W in D in 3.66 4.15 4.10 3.94 5.63 5.04 5.67 7.07 5.10 6.5 7.1 5.2 9.29 10.04 6.93 12.04 13.50 9.17 10.10 14.80 9.17 .24 x .24 6x6 .24 x .24 6x6 .24 x .24 6x6 .24 x .24 6x6 .47 x .47 12 x 12 .47 x .47 12 x 12 .47 x .47 12 x 12 26.6 35.5 70.9 195 195 248 248 Mechanical endurance Physical characteristics Shaft size square Switch operating torque for rotary 3 pole switches in mm lb. in. Terminal lug kits Wire range Torque: Wire tightening Lug mounting Integral Integral OZXA-24 OZXA-200 OZXA-400 OZXA-800 OZXA-27 AWG #18 - 8 #14 - 4 #14 - 2/0 #4 - 300kcmil #2 - 600kcmil (2) #2 - 600 kcmil (2) #2 - 600 kcmil lb. in. lb. in. 17 N/A 30 N/A 120 50 200 72 500 480 500 480 500 480 Auxiliary contacts OA4G_ OA1/3G_ OA_G_ OA_G_ OA_G_ OA_G_ OA_G_ OZXK-__ NEMA ratings, AC AC rated voltage VAC AC thermal rated current A VA AC maximum volt ampere making VA AC maximum volt ampere breaking -- 250 6 -- -- A600 600 10 7200 720 A600 600 10 7200 720 A600 600 10 7200 720 A600 600 10 7200 720 A600 600 10 7200 720 A600 600 10 7200 720 A600 600 10 7200 720 NEMA ratings, DC DC rated voltage VDC DC thermal rated current A DC maximum make break current A -- -- -- -- P300 300 1 28 R300 300 1 28 R300 300 1 28 R300 300 1 28 P600 600 1 28 P600 600 7 28 P600 600 5 138 Torque: 18 Wire tightening lb. in. 7 7 7 7 7 7 7 Wire range AWG #22 - 14/#18 - 14 #18 - 14 #18 - 14 #18 - 14 #18 - 14 #18 - 14 #20 - 12 1 The following UL Listed switches are also CSA approved. 18.64 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Te itch nec ch e t da nica s ta l Technical data OS30FA_12 - OES800L3 IEC IEC Catalog number 3 pole Technical ratings OS60J12 OS100J03 OS200J03 OS400J03 OS600J03 OES800L3 -40 to 40C Rated insulation voltage Pollution degree 3 6 Dielectric strength OS30FA_12 V 50Hz/60Hz, 1 min kV Rated impulse withstand voltage kV 1000 1000 1000 1000 1000 1000 10 10 10 10 10 10 1000 10 12 12 12 12 12 12 12 32/3.5 32/3.5 32 63/7.5 63/7.5 85 160/12 160/10, 135/12 175 200/17 200/17 280 400/45 400/34, 360/37 450 630/60 600/45, 570/50 700 800/65 720/55 900 Rated thermal current, Ith/ max. fuse power dissipation 1 AC 20/DC 20 open 2 40C enclosed Enclosed with solid links A/W A/W A/W with minimum cable cross section Cu mm2 6 16 70 95 240 2 x 185 2 x 240 Rated operational voltage AC 20 and DC 20V 1000 1000 1000 1000 1000 1000 1000 AC Rated operational currents AC 21A 500V 690V A A 32 32 63 63 160 160 200 200 400 630 400630 800 800 AC 22A 500V 690V A A 32 32 63 63 160 160 200 200 400 400 630 630 800 800 AC 23A 500V 690V A A 32 32 63 5 63 5 160 5 160 5 200400 200 400 630 630 720 720 DC Rated operational currents/poles in series DC21A 48V 110V 220V 440V 750V 1000V A 32/2 3 A 32/2 A 32/2 A 32/4 A -- A-- 4 4 4 63/4 4 4 4 4 4 160/3 4 4 200/1 200/1 200/1 200/2 180/4 -- 400/2 400/2 400/2 400/2 400/3 400/4 -- -- -- -- -- -- 800/2 800/2 800/2 800/2 800/3 800/4 DC22A 48V 110V 220V 440V 750V 1000V A 32/2 3 A 32/2 A 32/2 A 32/4 A -- A-- 4 4 4 63/4 4 4 4 4 4 160/3 4 4 200/1 200/1 200/1 200/2 180/4 -- 400/2 400/2 400/2 400/2 400/3 400/4 -- -- -- -- -- -- 800/2 800/2 800/2 800/2 800/3 800/4 DC23A 48V 110V 220V 440V 750V 1000V A A A A A A 4 4 4 63/4 4 4 4 4 4 160/3 4 4 200/1 200/1 200/1 200/2 180/4 -- 400/2 400/2 400/2 400/2 400/3 -- -- -- -- -- -- -- 800/2 800/2 800/2 800/2 800/3 800/4 18.5 30 30 37 60 45 80 90 110 132 60 110 110 140 190 132 220 230 280 400 200 355 355 450 630 200 350 380 470 600 Rated operational power 230V 400V 415V 500V 690V AC23A kW kW kW kW kW 32/2 3 32/2 32/2 32/4 -- -- 8 14 15 18 25 18 1 2 3 4 5 6 Load Load Load Load 2 poles in series 3 poles in series 4 poles in series 2 + 2 parallel contacts in series Ambient temperature 60C: derating 20 percent. Mounting on ceiling: derating 10 percent. Mounting on wall, horizontal fuses: derating 8 percent. The ambient air temperature does not exceed +40C and its average over a period of 24h does not exceed +35C according to IEC 947. For 30A switches, use 2 + 2 parallel contacts in series. Available on request. IEC 947-3, utilization category B, infrequent operation. Pollution degree 3: Conductive pollution occurs, or dry, non-conductive pollution occurs, which becomes conductive due to condensation. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.65 1SXU000023C0202 ct ne s n o he l sc Di witc nica s ch a Te dat Technical data OS30FA_12 - OES800L3 IEC IEC Catalog number 3 pole OS30FA_12 OS60J12 OS100J03 OS200J03 OS400J03 OS600J03 OES800L3 Rated breaking capacity in category AC-23A 500V 690V A A 256 256 504 504 1280 1280 1600 1600 3200 3200 5760 5760 5760 5760 128/2 128/4 -- -- -- -- -- -- -- -- -- -- 1000/2 1000/2 1000/3 -- 1600/2 1600/2 1600/3 -- 3200/2 3200/2 3200/3 3200/4 3200/2 3200/2 3200/3 3200/4 9 7.5 6 1 17 17 13 2.5 22 22 15 5 35 37.5 35 8 40 40 35 10 75 75 60 16 75 75 60 16 Rated capacitor power The capacitor rating of the fusible disconnect switch is limited by the fuse link 400 V kVar 415V kVar 690V kVar 15 15 25 30 32 50 -- -- -- -- -- -- 180 200 325 250 270 450 310 340 550 Power loss/pole with rated current, without fuse W Mechanical endurance operations 2 20,000 4 20,000 9 20,000 8 20,000 30 16,000 46 10,000 77 10,000 -- 10 x 38, 14 x 51 A1, A2, F1 000, 00 14 x 51, 22 x 58 A2 - A3 000, 00 22 x 58 A2 - A4 -- -- B1 - B2 0-2 0-2 B1 - B4 3 3 C1 - C2 3 -- C1 - C3 Rated breaking capacity/poles in series in category DC-23 <220V 440V 500 - 750V 1000V A A A A Rated conditional short-circuit current r.m.s. 3 80 kA, 415V kA 100 kA, 500 V kA 50 kA, 690 V kA Rated short time withstand current, 1s. kA Fuse types, IEC 269-2 DIN 43620 NFC BS 88 size/distance of link bolts M4/44.5(A1) M5/73 M5/73(A2) M5/73 M6/111 M8/111 M10/133, 184 M8/94 M10/133, 184 Physical characteristics Weight 3 pole 4 pole kg kg 0.7 0.9 1.3 1.6 1.5 1.8 2.6 7.9 5.7 6.9 13.0 17.0 17.0 21.0 Dimension 3 pole H mm W mm D mm 93 106 104 100 143 120 144 179 129 198.5 181.5 132 236 255 176 306 343 233 282 376 233 6x6 6x6 6x6 6x6 12 x 12 12 x 12 12 x 12 0.5 - 10 2.5 - 25 -- -- -- -- -- -- 2 2 -- 3.5 3.5 M6 x 20 6-9 3.5 - 5 M8 x 25 15 - 22 4 M10 x 40 30 - 44 15 M12 x 40 50 - 75 40 M12 x 40 50 - 75 40 Shaft size square mm Terminals 2 Built-in terminal size mm Terminal bolt size, metric thread diameter x length mm -- Terminal bolt tightening torque Nm Fuse-links bolts tightening torque Nm Operating torque 18 Nm Auxiliary contacts Ratings according to IEC 947-5-1 VAC Rated voltage, Ui A Thermal current, Ith Ue=24V A AC12 / DC12, Ie 120V A 125V A 230V A 250V A 400V A 415V A 440V A 480V A 500V A 600V A 690V A 4 8 7 22 28 28 OA4G_ 1 3 OA1/3G 2 OA_G_ 2 OA_G_ 2 OA_G_ 2 OA_G_ OA_G_ OZXK-_ 690 10 --/6 --/6 -- -- 3 / 0.1 -- -- 2/-- -- -- -- -- 690 16 -- -- -- 6/-- -- 4/-- -- -- -- -- -- 2/-- 690 16 -- -- -- 6/-- -- 4/-- -- -- -- -- -- 2/-- 690 16 -- -- -- 6/-- -- 4/-- -- -- -- -- -- 2/-- 690 16 -- -- -- 6/-- -- 4/-- -- -- -- -- -- 2/-- 690 16 -- -- -- -- -- -- -- -- -- -- -- 2/-- 690 16 -- -- -- -- -- -- -- -- -- -- -- 2/-- 690 10 -- 8 /-- -- / 1.1 6/-- -- / 0.55 4/-- 4/-- -- / 0.31 3/-- 3 / 0.27 -- / 0.2 2/-- 1 AC15 / DC12, according to IEC 947-5-1 2 AC15, according to IEC 947-5-1 3 Values shown are corresponding max. allowed cut-off current, peak-values per single phase fuse tests. 18.66 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Te itch nec ch e t da nica s ta l Auxiliary contact timing diagrams OT16 - OT100 Legend 0 30 60 90 ON Main contacts N.O. auxiliary contact OFF O OFF I ON N.C. auxiliary contact OFF 0 ON I = Contacts in closed position = Contacts in closed position Contacts closing Contacts opening 1 Main contacts close 2 N.O. auxiliary contacts close 3 N.C. auxiliary contacts open 4 Main contacts open 5 N.O. auxiliary contacts open 6 N.C. auxiliary contacts close 0 OT16, OT25, OT40 Catalog number OT16, OT25, OT40 30 60 90 Main contacts Auxiliary contact Contact configuration OA1G10 N.O. auxiliary contact OA1G10 OA1G01 OA2G11 1 N.O. 1 N.C. 1 N.O. & 1 N.C. OA1G01 N.C. auxiliary contact OA2G11 N.O. auxiliary contact N.C. auxiliary contact OFF 0 ON I = Contacts in closed position = Contacts in closed position 0 30 60 90 Main contacts OT63, OT80 Catalog number OT63, OT80 OA1G10 N.O. auxiliary contact Auxiliary contact Contact configuration OA1G10 OA1G01 OA2G11 1 N.O. 1 N.C. 1 N.O. & 1 N.C. OA1G01 N.C. auxiliary contact OA2G11 N.O. auxiliary contact N.C. auxiliary contact OFF 0 ON I 18 = Contacts in closed position = Contacts in closed position 0 Catalog number 60 90 Main contacts OT30, OT60, OT100 OT30, OT60, OT100 30 Auxiliary contact Contact configuration OA1G10 OA1G01 OA2G11 1 N.O. 1 N.C. 1 N.O. & 1 N.C. OA1G10 N.O. auxiliary contact OA1G01 N.C. auxiliary contact OA2G11 N.O. auxiliary contact N.C. auxiliary contact OFF 0 ON I = Contacts in closed position = Contacts in closed position Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.67 1SXU000023C0202 ct ne s n o he l sc Di witc nica s ch a Te dat Auxiliary contact timing diagrams OT200U - OETL-NF3150 OT200U03 - OT600U03 Catalog number Auxiliary contact Contact configuration OT200U03 - OA1G10 OT600U03 OA3G01 1 N.O. 1 N.C. ON and OFF- functions of main and auxiliary contacts Shaft movement Contact type Handle movement TEST -45 Main contacts 0 0 I I NO contacts inside the mechanism 0 0 I I NC contacts inside the mechanism 0 0 I I NO test indication-only contacts inside the mechanism 0 0 I I NC test indication-only contacts inside the mechanism 0 0 I I NO auxiliary contacts in the module on the side of the switch 0 0 I I NC auxiliary contacts in the module on the side of the switch 0 0 I I OFF 0 30 60 ON 90 0 OETL-NF800A - OETL-NF3150 Catalog number Auxiliary contact Contact configuration OETL-NF800A - OETL-NF3150 OZXK-1 OZXK-2 OZXK-3 1 N.O. & 1 N.C. 2 N.O. & 2 N.C. 4 N.O. & 4 N.C. 30 60 90 Main contacts N.O. auxiliary contact N.C. auxiliary contact OFF 0 ON I = Contacts in closed position = Contacts in closed position OZXK-1 OZXK-2 OZXK-3 18 18.68 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Te itch nec ch e t da nica s ta l Auxiliary contact timing diagrams OS30_ - OS100 Legend 30 60 0 I 0 I 4 Main contacts N.O. auxiliary contact 3 N.C. auxiliary contact ON 90 a 1 I ON O OFF 0 OFF 2 5 6 OFF 0 ON I = Contacts in closed position = Contacts in closed position Contacts closing 1 Main contacts close 2 N.O. auxiliary contacts close 3 N.C. auxiliary contacts open Contacts opening 4 Main contacts open 5 N.O. auxiliary contacts open 6 N.C. auxiliary contacts close OS30_ Catalog number OS30_ -45 Auxiliary contact OA4B1C OA1G10 OA3G01 Contact configuration 1 N.O. & 1 N.C. 1 N.O. 1 N.C. 0 30 60 90 a Main contacts OA4B1C N.O. auxiliary contact OA4B1C N.C. auxiliary contact OA1G10 N.O. auxiliary contact OA3G01 N.C. auxiliary contact Test OS60 Catalog number OS60 -45 Auxiliary contact Contact configuration OA1G10 OA3G01 1 N.O. 1 N.C. 0 30 60 90 a 30 60 90 Main contacts Installed in mechansim OA1G10 N.O. auxiliary contact OA3G01 N.C. auxiliary contact Installed on side of switch OA1G10 N.O. auxiliary contact OA3G01 N.C. auxiliary contact Test OS100 Catalog number OS100 -45 Auxiliary contact Contact configuration OA1G10 OA3G01 1 N.O. 1 N.C. 0 Main contacts Ins talled in mechanis m N.O. auxiliary contact OA3G01 N.C. auxiliary contact Ins talled on s ide of s witch OA1G10 N.O. auxiliary contact OA3G01 N.C. auxiliary contact T es t location OA1G10 N.O. auxiliary contact OA3G01 N.C. auxiliary contact Test Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.69 1SXU000023C0202 18 ct ne s n o he l sc Di witc nica s ch a Te dat OS200 - OS600 ON and OFF- Auxiliary contact timing diagrams OS200 - OES800 functions of main and auxiliary contacts Shaft movement Contact type Handle movement TEST -45 Main contacts 0 0 I I NO contacts inside the mechanism 0 0 I I NC contacts inside the mechanism 0 0 I I NO test indication-only contacts inside the mechanism 0 0 I I NC test indication-only contacts inside the mechanism 0 0 I I NO auxiliary contacts in the module on the side of the switch 0 0 I I NC auxiliary contacts in the module on the side of the switch 0 0 I I OFF 0 30 60 ON 90 OES800 Catalog number OES800 Auxiliary contact Contact configuration OZXK-1 OZXK-2 OZXK-3 OZXK-4 OZXK-5 OZXK-6 1 N.O. & 1 N.C. 2 N.O. & 2 N.C. 4 N.O. & 4 N.C. 2 N.O. 4 N.O. 8 N.O. 0o 30 o 60 o o 90 Main contacts N.O. auxiliary contact N.C. auxiliary contact OZXK-1 OZXK-2 OZXK-3 OZXK-4 OZXK-5 OZXK-6 18 18.70 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Te itch nec ch e t da nica s ta l Technical data Other configuration descriptions Conversion mechanisms 6 or 8 pole 2 6 (8) pole mechanism allows two switches controlled by one handle to open or close simultaneously. POS. O POS.I SW. A O X SW. B O X X = Closed O = Open 2 Double throw1 Transfer mechanism manually transfers between two power sources using two switches and a center "OFF" position. SW. A SW. B SW. A SW. B SW. A SW. B LOAD LOAD LOAD I O II POS. I POS.O POS.II SW. A X O O SW. B O O X X = Closed O = Open 2 Bypass1 Bypass mechanism operates three switches: Two switches in series and one changeover switch to allow power bypass. POS. I POS.O POS.II SW. A O O X SW. B O O X SW. C X O O X = Closed O = Open I Mechanical interlock O II 2 Mechanical interlock mechanism prevents both switches from being in the ON position at the same time. SW. A SW. B POS. I POS. O SW. A X O SW. B O X X = Closed O = Open 18 1 Transfer and bypass enclosed switches include the load side bussed or cabled together and all switches come standard with ground lugs. 2 = Three poles Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.71 1SXU000023C0202 ct ne s n o he l sc Di witc nica s ch a Te dat NEMA Environmental ratings Introduction An enclosure is a surrounding case constructed to provide a degree of protection to personnel against accidental contact with the enclosed equipment and to provide a degree of protection to the enclosed equipment against specified environmental conditions. A brief description of the more common types of enclosures used by the electrical industry relating to their environmental capabilities follows. Refer to NEMA Standards Publication for more information regarding applications, features and design tests. Individual NEMA product Standards Publications or third party certification standards may contain additional requirements for product testing and performance. Definitions pertaining to nonhazardous locations Type 1 Enclosures are intended for indoor use primarily to provide a degree of protection against limited amounts of falling dirt. (NEMA Standard 7-15-1991.) Type 3R Enclosures are intended for outdoor use primarily to provide a degree of protection against rain, sleet and damage from external ice formation. (NEMA Standard 7-15-1991.) Definitions pertaining to hazardous locations Type 4X Enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, hose-directed water and damage from external ice formation. (NEMA Standard 1-10-1979) Type 7 Enclosures are intended for indoor use in locations classified as Class I, Groups, A, B, C, or D, as defined in the National Electrical Code. (NEMA Standard 7-15-1991.) Type 12 Enclosures are intended for indoor use primarily to provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. (NEMA Standard 7-15-1991.) Type 9 Enclosures are intended for indoor use in locations classified as Class II, Groups E, F, or G, as defined in the National Electrical Code. (NEMA Standard 7-15-1991.) Legend - Indoors 18 Type 4 Enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose-directed water and damage from external ice formation. (NEMA Standard 1-10-1979.) 18.72 1SXU000023C0202 Type 13 Enclosures are intended for indoor use primarily to provide a degree of protection against dust, spraying of water, oil and noncorrosive coolant. (NEMA Standard 1-10-1979.) - Outdoors - Water - Dirt/dust X - Corrosion Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Te itch nec ch e t da nica s ta l IEC Environmental ratings IP ratings indicate the degree of protection against dust, liquids and impacts. The IP degrees of protection are defined by the French standard NFC 20-010. To rate a device's degrees of protection, the letters IP are followed by up to three numbers. These numbers are defined as follows: first number second number protection against solid objects no protection protected against solid objects over 50mm (e.g. accidental touch by hands.) 1 protected against solid objects over 12 mm (e.g. fingers) protected against solid objects over 2.5 mm (tools & wires) protected against solid objects over 1mm (small tools & small wires) 4 protected against dust (no harmful deposit) 5 totally protected against dust IP 0 1 2 3 4 5 6 protection against liquids Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage third number protection against mechanical impacts no protection impact 0,225 joule 150g falling from 15 cm 2 impact 0,375 joule 250g falling from15 cm 3 impact 0,50 joule 250g falling from 20cm 5 impact 2,00 joule 500g falling from 40 cm impact 6,00 joule 1.5kg falling from 40 cm impact 20,00 joule 5 kg falling from 40 cm no protection protected against vertically falling rain or condensation 1 2 protected against direct sprays of water up to 15 from vertical 3 protected against sprays to 60 from vertical IP 0 protected against water sprayed from all directions IP 0 protected against low pressure jets of water from all directions 7 6 protected from strong jets of water (e.g. for use on ship decks) 9 7 protected against the effects of immersion between 15cm and 1m 18.73 1SXU000023C0202 18 ct ne s n o he l sc Di witc nica s ch a Te dat Definitions AC - Alternating current -- Current that reverses its direction of flow twice per cycle. Ambient temperature -- Temperature of the air surrounding the unit. Amp rating -- The basic unit of measurement for electric current (columbs / seconds). Conventional thermal current Ith -- Value of the current the disconnect switch can withstand with poles in closed position, in free air for an eight hour duty, without the temperature rise of its various parts exceeding the limits specified by the standards. Cycle duration -- Total time of the on-load + off-load period. DC - Direct current -- Current that flows in only one direction. Electrical endurance -- Number of on-load operating cycles. IEC environmental protection type -- see page 18.48. Full load amp current FLA -- The current required by a motor to produce full-load torque at the motor's rated speed. Inductive load -- An electrical load characterized by having significant inrush (5 to 6 times FLA for typical design-B AC induction motors). kW -- Kilowatts (1000 watts) Lockout/Tagout -- Means of removing power from electrical equipment during inspection, service or repair. Make / Break -- ON / OFF Mechanical endurance -- Number of off-load operating cycles. Poles in series -- Means of connection poles using wires or bus bars to increase breaking capacity of load. Power factor -- The relationship between working power and total power consumed. Power factor measures how effectively electrical power is being used. 18 Rated insulation Ui -- Voltage value which designates the unit and to which dielectric tests, clearance and creepage distances are referred. 18.74 1SXU000023C0202 Rated operating current Ie --Current value stated by the manufacturer and taking into account the rated operating voltage Ue, the rated frequency, the rated duty, the utilization category, the electrical contact life and the type of protective enclosure. Rated operating voltage Ue -- Voltage value to which utilization characteristics of the disconnect switch are referred, i.e. phase-to-phase voltage in 3 phase circuits. Rated short circuit making capacity Icm-- The rated shortcircuit making capacity of a disconnect switch, a disconnector or a switch-disconnector is the value assigned to equipment at the rated operational voltage, frequency (if any) and specified power-factor for AC or time constant for DC. It is expressed as the maximum prospective peak current under prescribed conditions. Rated short time withstand current Icw -- The rated shorttime withstand current of a disconnect switch, a disconnector or a switch-disconnector is the value that the equipment can carry without damage, under the test conditions specified in the relevant product standard. The value of the rated shorttime withstand current shall be not less than twelve times the maximum rated operational current unless otherwise stated by manufacturer and the duration of the current shall be 1 s. Resistive load -- An electrical load characterized by not having any significant inrush current. Short circuit protection coordination -- Co-ordination types "1" and "2" are defined in IEC 947-4-1. Type 1 coordination -- There has to be no discharge of parts beyond the enclosure. Damage to the contactor and the overload is acceptable. Type 2 coordination -- No damage to the overload relay or other parts has occurred, except that welding of contactor or starter contacts is permitted, if they are easily separated. Time constant -- Ratio of inductance to the resistance: L/R = mH/Ohm = ms. Torque -- The force that produces rotation. It is commonly measured in pound-feet (lb-ft). Torque applies to such things as motor operations, handle rotations, wire tightening. NEMA environmental protection type -- see page 18.47. Volt -- The unit of electrical potential difference and electromotive force. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 00.00 Inches 00.00 [Millimeters] Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions OT16F3 - OT100F3 Base & DIN rail mounted switches OT16F3, OT25F3, OT40F3 -- base & DIN rail mounted switch 0.43 0.43 0.18 DIA. 11 4.5 0.24 0.20 56 11 0.47 12 1.38 2.36 2.13 35 60 54 2.68 68 0.87 1.77 22 0.43 1.38 11 45 0.51 35 13 2.20 56 OT63F3, OT80F3 -- base & DIN rail mounted switch 0.69 0.18 DIA. 0.69 17.5 OT16,25,32 17.5 0.24 0.20 56 4.5 0.59 15 3.60 3.25 2.85 1.38 91.5 82.5 72.5 35 2.47 1.71 63 43.5 0.43 2.89 2.07 11 52.5 73.5 0.69 17.5 OT30F3, OT60F3, OT100F3 -- base & DIN rail mounted switch 0.18 DIA. 4.5 0.88 OT45,63 0.88 22.5 22.5 0.59 15 0.24 0.20 56 3.94 3.54 90 100 3.94 100 11 70 1.04 2.93 26.5 74.5 18.75 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 35 63 56 2.76 1.38 2.48 2.20 0.43 18 OT100E3 1SXU000023C0202 ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions OT16FT3 - OT100FT3 Door mounted switches 00.00 Inches 00.00 [Millimeters] OT16FT3, OT25FT3, OT40FT3 -- door mounted switch 2.64 67 0.43 0.43 0.51 11 2.05 0.06 0.08 11 13 52 1.5 2 2.13 54 0.88 22 0.43 1.38 11 MOUNTING HOLE DETAIL 0.51 35 13 1.69 43 OT 16 & 32ET OT63FT3, OT80FT3 -- door mounted switch 1.89 48 0.69 2.72 0.69 17.5 69 1.42 17.5 0.69 17.5 36 0.71 18 0.71 18 0.16 D 4 0.71 18 0.71 0.88 D 22 2.85 1.42 1.89 36 72.5 48 18 MOUNTING HOLE DETAIL 2.56 65 2.07 0.43 11 52.5 0.69 17.5 OT30FT3, OT60FT3, OT100FT3 -- door mounted switch OT63ET3 0.88 66.5 0.55 14 0.88 0.88 22.5 22.5 2.20 56 1.89 18 48 0.94 24 0.94 0.16 D 24 4 0.94 24 1.89 2.20 48 3.94 100 56 0.94 24 0.88 D 22 MOUNTING HOLE DETAIL 0.43 11 18.76 1SXU000023C0202 OT100ET3 2.76 70 1.04 26.5 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 00.00 Inches 00.00 [Millimeters] Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions OT16F6 - OT100F6 6-pole switches OT16, 25, 40F6 -- 6 Pole switches 0.43 0.51 0.43 0.43 0.51 11 13 11 11 13 1.38 35 1.12 28.5 0.18 DIA. 4.5 1.85 0.20 0.24 5 6 47 shaft depth 2.68 68 1.12 28.5 0.43 11 35mm DIN rail 2.36 60 2.13 54 1.38 35 2.22 56.5 2.76 70 0.51 13 0.43 11 0.51 13 2.68 68 OT63, OT80F6 -- 6 Pole switches 0.69 17.5 0.18 DIA. 4.5 0.69 17.5 0.69 17.5 0.69 17.5 0.69 17.5 2.07 52.5 2.40 1.89 48 61 shaft depth 0.24 0.24 6 6 3.60 91.5 3.25 82.5 35mm DIN rail 2.85 72.5 1.89 48 0.69 17.5 0.43 11 2.95 75 2.07 52.5 0.69 17.5 4.13 105 3.31 84 0.43 11 OT30, OT60, OT100F6 -- 6 Pole switches 0.18 DIA. 4.5 0.88 22.5 0.88 22.5 0.98 25.0 0.88 22.5 2.76 70 0.88 22.5 18 2.50 2.48 63 63.5 shaft depth 0.24 0.24 6 6 3.94 100 3.94 100 3.54 90 2.48 63 0.43 11 1.04 26.5 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 35mm DIN rail 2.99 76 2.76 70 5.51 140 1.04 26.5 3.43 87 18.77 1SXU000023C0202 ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions OT16 - OT100F3C Double throw switches 00.00 Inches 00.00 [Millimeters] OT16, OT25, OT40F3C - Double throw switches 0.43 0.51 0.43 0.43 0.51 11 13 11 11 13 1.38 35 1.12 28.5 0.18 DIA. 4.5 1.85 0.20 5 47 shaft depth 2.68 68 1.12 28.5 0.43 11 35mm DIN rail 2.36 60 2.13 54 1.38 35 2.22 56.5 2.76 70 0.51 13 0.43 11 0.51 13 2.68 68 OT45, OT63, OT80F3C - Double throw switches 0.69 17.5 0.18 DIA. 4.5 0.69 17.5 0.69 17.5 0.69 17.5 0.69 17.5 2.07 52.5 2.40 1.89 48 61 shaft depth 0.20 5 3.60 91.5 3.25 82.5 35mm DIN rail 2.85 72.5 1.89 48 0.69 17.5 0.43 11 2.95 75 2.07 52.5 0.69 17.5 4.13 105 3.31 84 0.43 11 OT30, OT60, OT100F3C - Double throw switches 0.18 DIA. 4.5 0.88 22.5 18 0.88 22.5 0.98 25.0 0.88 22.5 2.76 70 0.88 22.5 2.50 2.48 63 63.5 shaft depth 0.20 5 3.94 100 3.94 100 3.54 90 2.48 63 0.43 11 1.04 26.5 18.78 1SXU000023C0202 35mm DIN rail 2.99 76 2.76 70 5.51 140 1.04 26.5 3.43 87 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions OT160E3 & OT160ET3 00.00 Inches 00.00 [Millimeters] OT160E3 -- base & DIN rail mounted switch 6.69 170 5.67 144 3.35 85 0.24 6 3.35 85 4.69 1.38 119 5.00 5.16 127 35 131 2.34 59.5 1.42 1.42 36 36 2.36 0.18 DIA. 1.06 60 4.5 27 4.96 2.93 126 74.5 6.02 153 OT160E3 OT160ET3 -- Door mounted switch 1.06 27 1.42 1.42 36 36 1.06 27 0.24 2.09 6 5.00 127 0.20 D 53 5 5.16 131 2.34 59.5 45 1.22 D 18 31 3.31 84 3.01 2.91 76.5 74 4.96 3.50 126 89 6.02 MOUNTING HOLE DETAIL 153 OT160ET Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.79 1SXU000023C0202 ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions OT200_ -- OT400_ 00.00 Inches 00.00 [Millimeters] OT200U03 OT400U03 18 18.80 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions OT600U03 - OETL-NF800A 00.00 Inches 00.00 [Millimeters] OT600U03 OETL-NF800A 5.75 146 10.47 5.04 266 128 1.10 1.97 28 50 0.55 14 0.35 DIA. 9 0.59 15 0.47 12 19.21 14.65 488 18 372 7.48 8.35 190 212 3.74 95 1.56 39.5 0.94 3.54 24 90 8.07 2.07 52.5 205 11.61 295 0.79 272 14.25 362 12 1.57 40 15.16 4.92 385 125 (2 Pole) (3 Pole) (4 Pole) 10.71 0.47 20 17.80 452 (2 Pole) (3 Pole) (4 Pole) OETL-NF800A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.81 1SXU000023C0202 ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions OETL-NF1200 - OETL-NF1600 OETL-NF1200 00.00 Inches 00.00 [Millimeters] 5.75 146 10.47 5.20 266 132 1.10 1.97 28 50 0.55 14 0.35 DIA. 9 0.59 15 0.47 12 19.21 14.65 488 372 7.48 8.35 190 212 3.74 95 1.56 39.5 0.79 3.54 8.19 0.94 11.73 208 24 298 0.63 20 90 40 15.27 4.92 388 125 (2 Pole) (3 Pole) (4 Pole) 10.71 272 14.25 362 16 1.57 17.80 452 (2 Pole) (3 Pole) (4 Pole) OETL-NF1600 OETL-NF1200 0.55 DIA. 14 3.94 0.47 DIA. 12 100 1.58 40 1.28 0.79 32.5 20 1.38 1.58 35 0.35 DIA. 9 40 0.47 12 25.28 21.50 642 546 18 7.48 190 8.35 212 3.74 95 5.47 4.41 139 0.94 24 10.12 257 2-pole 12.63 321 2-pole 18.82 1SXU000023C0202 15.59 396 3-pole 18.11 460 3-pole 0.59 112 21.06 535 4-pole 15 10.67 271 23.58 599 4-pole OETL-NF1600 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions OETL-NF2000 - OETL-NF3150 00.00 Inches 00.00 [Millimeters] OETL-NF2000 - OETL-NF3150 0.55 DIA. 14 3.94 0.47 DIA. 12 100 1.58 40 1.28 0.79 32.5 20 1.38 1.58 35 0.35 DIA. 9 40 0.47 12 25.28 21.50 642 546 7.48 190 8.35 212 3.74 95 5.47 4.41 139 0.94 24 10.12 257 2-pole 12.63 321 2-pole 15.59 396 3-pole 18.11 460 3-pole 0.59 112 21.06 535 4-pole 15 10.67 271 23.58 599 4-pole OETL-NF2000,3150 18 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.83 1SXU000023C0202 ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions OS30FA_12 -- OS60J_12 00.00 Inches 00.00 [Millimeters] OS30FA_12 OS60J_12 18 18.84 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Approximate dimensions OS100J03 -- OS200J03 00.00 Inches 00.00 [Millimeters] Di s sw con Di itc ne me h ct ns es ion s OS100J03 OS200J03 18 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.85 1SXU000023C0202 ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions OS400J03 -- OS600J03 00.00 Inches 00.00 [Millimeters] OS400J03 OS600J03 18 18.86 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions OES800L3 00.00 Inches 00.00 [Millimeters] OES800L3 0.51 DIA. 1.42 13 36 1.58 40 0.63 16 0.35 DIA. 9 0.47 12 14.49 10.10 368 7.48 190 282 8.27 210 3.74 95 0.24 3.54 90 8.58 0.96 24.5 218 12.13 (2 Pole) 308 15.67 398 (3 Pole) (4 Pole) 11.26 14.80 18.35 (2 pole) (3 pole) (4 pole) 286 376 6 1.58 40 4.41 112 9.17 233 466 18 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.87 1SXU000023C0202 ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions for Terminal lugs OZXA-24 00.00 Inches 00.00 [Millimeters] OZXA-30 3.00 1.57 76 40 0.79 20 0.63 16 0.41 10.5 1.46 37 0.45 0.26 6.5 C.L. 11.5 0.10 4.92 2.5 125 0.18 4.5 OZXA-24 1.38 35 0.41 10.3 OZXA-28 & OZXA-28/2 OZXA-400 2.47 C.L. 0.37 9.5 0.75 19 OZXA-30 3.00 63 76 4.92 125 1.38 C.L. 35 0.41 10.3 C.L. 0.37 9.5 0.75 19 OZXA-28 OZXA-200 18 18.88 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions for Terminal lugs 00.00 Inches 00.00 [Millimeters] OZXA-406 OZXA-800 C.L. OZXA-32 2.47 3.00 63 76 4.92 125 1.38 35 0.41 C.L. 10.3 0.37 9.5 0.75 19 OZXA-32 18 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.89 1SXU000023C0202 ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions for 16A - 100A conversion mechanisms 6 or 8 pole -- OTZW8 0.20 6 30 + Inches 00.00 [Millimeters] For installation of 6 or 8 pole, transfer and bypass mechanisms, the following minimum and maximum mounting dimensions are given below. 0.24 1.18 00.00 5 (0...13) 0.59 STEPS 15 OTZW8 in combination with: Minimum inches/mm Maximum inches/mm OT16F3, OT25F3, OT40F3 3.07/78 N/A OT63F3, OT80F3 3.74/95 N/A OT30F3, OT60F3, OT100F3 3.82/97 N/A OESA-ZW1, OESA-ZW1X in combination with: Minimum inches/mm Maximum1 inches/mm OT16F3, OT25F3, OT40F3 4.61/117 6.57/167 OT63F3, OT80F3 5.31/135 7.28/185 OT30F3, OT60F3, OT100F3 4.84/123 6.81/173 OTZW17, OTZW17X in combination with: Minimum inches/mm Maximum1 inches/mm OT16F3, OT25F3, OT40F3 4.61/117 6.57/167 OT63F3, OT80F3 5.31/135 7.28/185 OT30F3, OT60F3, OT100F3 4.84/123 6.81/173 OETL-ZW24 in combination with: Minimum inches/mm Maximum1 inches/mm OT16F3, OT25F3, OT40F3 3.39 / 86 -- OT63F3, OT80F3 4.09 / 104 -- OT30F3, OT60F3, OT100F3 4.13 / 105 -- 0.59 15 Double throw switch -- OTZW6, OTZW6X OTZW81.18 2.83 72 1.54 39 30 2.17 55 0.24 6 1.54 39 0.20 5 10.71 272 3.54...9.45 90...240 15mm STEPS 0.59 15 0.24 6 Bypass switch -- OTZW17, OTZW17X OTZW6 1.18 30 2.83 72 1.54 39 2.17 55 0.24 6 1.54 39 0.24 6 3.54...8.27 90...210 15mm STEPS 10.71 272 0.24 6 0.59 15 4.72...9.45 120...240 15mm STEPS 18 0.24 6 Mechanical interlock -- OETL-ZW24 OTZW17 0.24 6 3.94 100 1 Deeper enclosures will require a longer shaft. Please select a 6mm shaft from page 18.5. 18.90 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions for 125 - 200A conversion mechanisms 00.00 Inches 00.00 [Millimeters] 6 or 8 pole -- OESA-ZW2 1.57 0.47 40 12 7.72 196 0.24 0.24 6 6 4.72 For installation of 6 or 8 pole, transfer and bypass mechanisms, the following minimum and maximum mounting dimensions are given below. 120 OESA-ZW2 in combination with: Minimum inches/mm Maximum inches/mm OT160 - OT200 5.35/136 9.49/241 NOTE: Deeper enclosures will require a longer shaft. Please select a 12mm shaft from page 18.7 and an OETL-ZX95 shaft extension coupler from page 18.10. 1.77...9.49 0.59 45...240 15 (15mm Steps) OESA-ZW2 Double throw switch -- OESA-ZW1, OESA-ZW1X 2.83 72 4.57 116 1.54 39 2.17 55 0.24 6 1.54 39 10.71 272 0.24 6 3.54...9.45 90...240 15mm STEPS 0.59 15 OESA-ZW1, OESA-ZW1X in combination with: Minimum inches/mm Maximum inches/mm OT160 - OT200 4.61/117 6.57/167 NOTE: Deeper enclosures will require a longer shaft. Please select a 6mm shaft from page 18.7 0.24 6 18 Mechanical interlock -- OESA-ZW1 OTZW10 0.24 5 OTZW10 in combination with: Minimum inches/mm Maximum inches/mm OT160 - OT200 4.13 / 105 -- NOTE: Deeper enclosures will require a longer shaft. Please select a 6mm shaft from page 18.7 7.48 190 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.91 1SXU000023C0202 ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions for 400A - 1200A conversion mechanisms 00.00 Inches 00.00 [Millimeters] 6 or 8 pole -- OETL-ZW9 For installation of 6 or 8 pole, transfer and bypass mechanisms, the following minimum and maximum mounting dimensions are given below. 1.46 37 OETL-ZW9 in combination with: Minimum inches/mm Maximum inches/mm OT400 7.52/191 N/A OT600 7.52/191 N/A OETL-NF800A 7.52/191 N/A OETL-NF1200 7.52/191 N/A OETL-ZW12 in combination with: Minimum inches/mm Maximum1 inches/mm OT400 8.19/208 11.73/298 OT600 8.19/208 11.73/298 OETL-NF800A 8.19/208 11.73/298 OETL-NF1200 8.19/208 11.73/298 NOTE: Handle not included 2.36...17.32 0.47 0.79 60...240 12 20 20mm Steps OETL-ZW9 Double throw -- OETL-ZW12 1.89 1.57 4.53 3.54 48 40 115 90 NOTE: Includes YASDA-21 handle 3.31 84 0.47 12 0.47 12 26.06 662 18 8.27...24.02 210...610 20mm steps 0.79 20 0.47 12 OETL-ZW12 1 Deeper enclosures will require a longer shaft. Please select a 12mm shaft from page 18.7 and an OETL-ZX95 shaft extension coupler from pg. 18.10. 18.92 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions for 400A - 3150A conversion mechanisms 00.00 Inches 00.00 [Millimeters] Bypass switch -- OETL-ZW13 2.07 4.53 3.54 115 90 3.31 52.5 1.32 33.5 0.47 84 12 For installation of 6 or 8 pole, transfer and bypass mechanisms, the following minimum and maximum mounting dimensions are given below. OETL-ZW12 in combination with: Minimum inches/mm Maximum1 inches/mm OT400 8.19/208 11.73/298 OT600 8.19/208 11.73/298 OETL-NF800A 8.19/208 11.73/298 OETL-NF1200 8.19/208 11.73/298 NOTE: Includes YASDA-21 handle 0.47 12 8.27...22.44 210...570 26.06 662 9.84...24.02 250...610 0.47 12 0.79 20 0.47 12 Mechanical interlock -- OETL-ZW3, OETL-ZW14, OETL-ZW15 OETL-ZW13 OETL-ZW3, 14 & 15 in combination with: Minimum inches/mm Maximum1 inches/mm OT400 & OT600 6.50/165 -- OETL-NF800 - OETL-NF1200 6.30/160 -- OETL-NF1600 - OETL-NF3150 12.00/305 -- NOTE: Handle(s) not included. NOTE: OETL-ZW15 is the only mechnical interlock OETL-NF1200 - OETL-NF3150 can use. B A Dimensions in Inches & mm A B OETL-ZW3 11.81 0.47 OETL-ZW14 OETL-ZW15 300.0 9.84 0.47 12.0 500.0 12.0 19.69 18 12.0 250.0 0.47 OETL-ZW3, 14, 15 1 Deeper enclosures will require a longer shaft. Please select a 12mm shaft from page 18.7 and an OETL-ZX95 shaft extension coupler from page 18.10. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.93 1SXU000023C0202 ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions for Handles Selector handles for base and DIN rail mounted switches Selector handles for door mounted switches OH_S1AH1 & OH_S3AH1 OH_S1P_ & OH_S3P_ 0.26 6.5 Inches 00.00 [Millimeters] 0.98 0.98 25 00.00 25 1.89 0.26 1.89 48 6.5 48 0.125 0.125 3.2 3.2 0.96 0.96 24.5 24.5 0.88 0.55 0.88 0.98 22.5 14 22.5 25 MOUNTING HOLE DETAIL MOUNTING HOLE DETAIL OH_1P, 3P OH_1A,3A OH_S2A_ OH_S1R_ & OH_S3R_ 0.98 1.30 1.42 25 33 2.56 0.39 10 36 1.89 0.26 65 0.71 48 6.5 0.71 18 18 0.53 13.5 0.125 0.16 D B 0.71 4 3.2 0.96 18 0.88 D 24.5 0.39 36 18 22 MOUNTING HOLE DETAIL 10 0.88 1.42 0.71 22.5 0.55 14 MOUNTING HOLE DETAIL OH_2A_ OH_1R, 3R OH_S2P_ 1.30 33 2.56 0.39 65 10 0.125 3.2 0.96 24.5 0.88 0.98 22.5 25 MOUNTING HOLE DETAIL OH_2P_ 18 OH_S2R_ 1.89 1.30 48 33 0.39 10 2.56 1.42 65 36 0.71 18 0.71 18 0.53 13.5 0.16 D 0.71 4 18 0.71 0.88 D 36 48 18 22 0.39 1.42 1.89 MOUNTING HOLE DETAIL 10 OH_2R_ 18.94 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions for Handles 00.00 Inches 00.00 [Millimeters] Pistol handles A L Catalog number Inches/ mm 2.66 1.77 67.5 45 2.09 B 53 0.24 0.20 6 5 D 1.22 D 31 45 L 100 OH_45J6 OH_65J6 OH_80J6 1.8/45 2.6/65 3.1/80 0.24/6 0.24/6 0.24/6 1, 3R, 12 1, 3R, 12 1, 3R, 12 OH_125J12 OH_145J12 OH_175J12 4.9/125 5.7/145 6.9/175 0.47/12 0.47/12 0.47/12 1, 3R, 12 1, 3R, 12 1, 3R, 12 OH_80L6 3.1/80 0.24/6 1, 3R, 4, 4X, 12 OH_145L12 5.7/145 0.47/12 1, 3R, 4, 4X, 12 OH_175L12 6.9/175 0.47/12 1, 3R, 4, 4X, 12 2.76 70.0 1.57 40 NEMA / UL Type __ = Handle color, B (Black) or Y (Red/Yellow) MOUNTING HOLE DETAIL 3.94 B Shaft size Inches/ mm B 2.20 56 0.28 D 7 45 1.77 D 45 A L catalog number inches/mm B Shaft size inches/mm NEMA Type YASDA-7 8.66/220 0.47/12 1, 3R, 4, 4X, 12 YASDA-8 8.66/220 0.47/12 1, 3R, 4, 4X, 12 YASDA-21 8.66/220 0.47/12 1, 3R, 4, 4X, 12 YASDA-6 12.60/320 0.47/12 1, 3R, 4, 4X, 12 MOUNTING HOLE DETAIL L 1.22 31 METAL HANDLE 1.46 18 .20 0.24 5 6 37 O 2.72 69 2.01 51 2.09 53 2.09 53 Handle type type OHM45L5 Handle L 1.8/45 L B .2/5 B Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage OHM65L5 OHM65L6 2.6/65 2.6/65 .2/5 .24/6 OHM65L6 OHM125L12 OHM175L12 OHM125L12 OHM175L12 OHM275L12 OHM275L12 2.6/65 4.9/125 4.9/125 6.9/175 10.8/275 6.9/175 10.8/225 .2/6 .5/12 .5/12 .5/12 .47/12 .47/12 .47/12 18.95 1SXU000023C0202 ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions 2, 3 & 4 Pole 2 30A - 800A Fusible Fusible Frame size OS30_ OS60_ OS100_ OS200_ Enclosure type MH MW H W D mtg. mtg. Weight height width depth height width 1 10.0 8.0 5.0 7.0 7.0 12 3R 10.0 8.0 5.0 10.75 6.0 12 4 10.0 8.0 6.0 10.75 6.0 12 4X SS 10.0 8.0 5.0 10.75 6.0 12 4X Plastic 10.0 8.0 5.9 10.75 6.0 8.0 12 10.0 8.0 5.0 10.75 6.0 12 1 10.0 8.0 6.0 7.0 7.0 13 3R 10.0 8.0 6.0 10.75 6.0 13 4 10.0 8.0 6.0 10.75 6.0 13 4X SS 10.0 8.0 6.0 10.75 6.0 13 4X Plastic 10.0 8.0 5.9 10.75 6.0 9.0 12 10.0 8.0 6.0 10.75 6.0 13 1 14.0 12.0 8.0 11.0 9.0 22 3R 14.0 12.0 8.0 14.75 10.0 22 4 14.0 12.0 8.0 14.75 10.0 22 4X SS 14.0 12.0 8.0 14.75 10.0 22 4X Plastic 14.0 12.0 8.0 14.75 10.0 16 12 14.0 12.0 8.0 14.75 10.0 22 1 24.0 16.0 8.0 25.5 14.5 75 3R 24.0 16.0 8.0 25.5 14.5 75 4 24.0 16.0 8.0 25.5 14.5 75 4X SS 24.0 16.0 8.0 25.5 14.5 75 4X Plastic 1 1 1 1 1 1 12 24.0 16.0 8.0 25.5 14.5 75 Frame size OS400_ OS600_ OES800_ Enclosure type 00.00 Inches 00.00 [Millimeters] MW H W D mtg. mtg. Weight height width depth height width 1 36.0 24.0 12.0 37.5 22.5 150 3R 36.0 24.0 12.0 37.5 22.5 150 4 36.0 24.0 12.0 37.5 22.5 150 4X SS 36.0 24.0 12.0 37.5 22.5 150 4X Plastic 1 1 1 1 1 1 12 36.0 24.0 12.0 37.5 22.5 150 1 42.0 36.0 12.0 43.5 34.5 150 3R 42.0 36.0 12.0 43.5 34.5 150 4 42.0 36.0 12.0 43.5 34.5 150 4X SS 42.0 36.0 12.0 43.5 34.5 150 4X Plastic 1 1 1 1 1 1 12 42.0 36.0 12.0 43.5 34.5 150 1 48.0 24.0 12.0 49.5 22.5 170 3R 48.0 24.0 12.0 49.5 22.5 170 4 48.0 24.0 12.0 49.5 22.5 170 4X SS 48.0 24.0 12.0 49.5 22.5 170 4X Plastic 1 1 1 1 1 1 12 48.0 24.0 12.0 49.5 22.5 170 D W 1 Please consult factory, enclosures are sized to suit specific customer needs. 2 Some 4-pole switches require larger enclosures. Please consult factory. H MH MW 18 18.96 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 00.00 Inches 00.00 [Millimeters] Non-Fusible Frame size OT16_ OT25_ OT40_ OT30_ OT60_ OT63_ OT80_ OT100 OT160 Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions 2, 3 & 4 Pole 3 16A - 3150A, Non-fusible Enclosure type MH MW H W D mtg. mtg. Weight height width depth height width 1 7.0 5.0 3.0 4.0 4.0 4.0 3R 7.0 5.0 3.0 7.75 3.0 4.0 4 6.0 6.0 4.0 6.75 4.0 4.0 4X SS 7.0 5.0 3.0 7.75 3.0 4.0 4X Plastic 6.0 6.0 5.9 6.75 4.0 4.0 12 7.0 5.0 3.0 7.75 3.0 4.0 IP65 (A) 4.8 3.4 2.4 4.17 2.80 1.0 IP65 (B) 5.9 5.1 2.4 5.35 4.57 1.0 1 8.0 6.0 4.0 7.0 5.0 6.0 3R 8.0 6.0 4.0 8.75 4.0 6.0 4 8.0 6.0 4.0 8.75 4.0 6.0 4X SS 8.0 6.0 4.0 8.75 4.0 6.0 4X Plastic 8.0 6.0 5.9 8.75 4.0 6.0 12 8.0 6.0 4.0 8.75 4.0 6.0 IP65 (A) 7.9 5.7 3.6 7.24 5.16 4.0 IP65 (B) 15.8 7.9 5.5 14.8 6.93 4.0 1 10.0 8.0 5.0 7.0 7.0 9.0 3R 10.0 8.0 5.0 10.75 6.0 9.0 4 10.0 8.0 4.0 10.75 6.0 9.0 4X SS 10.0 8.0 5.0 10.75 6.0 9.0 4X Plastic 10.0 8.0 5.9 10.75 6.0 9.0 12 10.0 8.0 5.0 10.75 6.0 9.0 IP65 (A) 7.9 5.7 3.6 7.24 5.16 4.0 IP65 (B) 15.8 7.9 5.5 14.8 6.93 4.0 1 14.0 12.0 8.0 11.0 9.0 20 3R 14.0 12.0 8.0 14.75 10.0 20 4 14.0 12.0 6.0 14.75 10.0 20 4X SS 14.0 12.0 8.0 14.75 10.0 20 4X Plastic 14.0 12.0 6.0 14.75 10.0 12 12 14.0 12.0 8.0 14.75 10.0 20 Frame size OT200 OT400 OT600 OETL-NF800A OETL-NF1200 OETL-NF1600 OETL-NF2000 OETL-NF3150 Enclosure type MW H W D mtg. mtg. Weight height width depth height width 1 20.0 16.0 6.0 25.5 14.5 50 3R 20.0 16.0 6.0 25.5 14.5 50 4 20.0 16.0 6.0 25.5 14.5 50 4X SS 20.0 16.0 6.0 25.5 14.5 50 4X Plastic 20.0 16.0 8.0 25.5 14.5 40 12 20.0 16.0 6.0 25.5 14.5 50 1 36.0 24.0 8.0 37.5 22.5 120 3R 36.0 24.0 8.0 37.5 22.5 120 4 1 1 1 1 1 1 4X SS 36.0 24.0 8.0 37.5 22.5 130 4X Plastic 1 1 1 1 1 1 12 36.0 24.0 8.0 37.5 22.5 120 1 36.0 24.0 12.0 37.5 22.5 120 3R 36.0 24.0 12.0 37.5 22.5 120 4 36.0 24.0 12.0 37.5 22.5 120 4X SS 36.0 24.0 12.0 37.5 22.5 120 4X Plastic 40.0 32.0 12.0 41.2 30.2 120 12 36.0 24.0 12.0 37.5 22.5 120 1 60.0 36.0 12.0 61.5 34.5 200 3R 60.0 36.0 12.0 61.5 34.5 200 4 60.0 36.0 12.0 61.5 34.5 200 4X SS 60.0 36.0 12.0 61.5 34.5 200 4X Plastic 1 1 1 1 1 1 12 60.0 36.0 12.0 61.5 34.5 200 1 90.0 36.0 24.0 2 2 600 3R 90.0 36.0 24.0 2 2 600 4 1 1 1 1 1 1 4X SS 1 1 1 1 1 1 4X Plastic 1 1 1 1 1 1 12 90.0 36.0 24.0 2 2 600 1 Please consult factory, enclosures are sized to suit specific customer needs. 2 Enclosure is free standing. 3 Some 4-pole switches require larger enclosures. Please consult factory. D W H 18 MH MW 600V, 16A - 3150A 2, 3 and 4-pole switches Enclosure dimensions Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18.97 1SXU000023C0202 ct ne s n o he s sc Di witc sion s en m Di Notes 00.00 Inches 00.00 [Millimeters] 18 18.98 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage