Product catalogue ELESTA Relays with forcibly guided contacts Relays with forcibly guided contacts in 25 basic series Product catalogue - relays with forcibly guided contacts Edition 04/2018 Publisher: ELESTA GmbH, Bad Ragaz, Switzerland All rights reserved. The work and its parts are protected by copyright. Any use other than the legally approved cases therefore requires the prior written consent of the publisher. Until the 1980s, ELESTA stood for Swiss innovation in electromechanics and electronics. When the new ELESTA relays GmbH was founded in March 1997 from the legacy of the "old" ELESTA Elektronik AG, the company concentrated on the production of relays with forcibly guided contacts. Later, the fields of business for customer-specific development and production services as well as sensor technology were added. Some of the product innovation milestones are the smallest, most energy-efficient and flattest relay. The small SIS 212 relay was awarded the innovation prize of the SME Primus in 2005. A success factor of today's company is the implementation of the philosophy of lean management, increasing efficiency and combating waste in the company. ELESTA was awarded the "Swiss Lean Award" for this in 2012. What began in 1997 with around a dozen employees and the production of a few relays became a success story. In the middle of Europe, one of the most innovative manufacturers of relays was able to establish itself successfully worldwide. Today, our range of products and services includes relays with forcibly guided contacts with 25 basic series as well as optical miniature encoders and the development and manufacture of customer-specific sensors for functional safety. In 2013, ELESTA relays GmbH was Harald Forster Geschaftsfuhrer / CEO ELESTA GmbH renamed ELESTA GmbH. The continuous growth of the three product areas makes it essential to expand production capacities. We expect further strong growth in the coming years. ELESTA shows that with welltrained, motivated employees and a well thought-out production and management concept, maximum competitiveness can be achieved. Product Overview Relays with forcibly guided contacts Relays SIS 2 / SIS 2 SEN Properties SIS 3 / SIS 3 SEN SIS 4 / SIS 4 SEN SIS 6 / SIS 6 SEN SISF 3 Small dimensions Small dimensions High shock resistance Very compact design Available mid 2018 High shock resistance High shock resistance High shock resistance Very flat design Large or very large excitation voltage range Large or very large excitation voltage range Large or very large excitation voltage range Low or very low coil power Very low coil power with sensitive coil High contact reliability Low or very low coil power Large or very large excitation voltage range High contact reliability High contact reliability High contact reliability SIF 3 SIF 4 SIF 6 Very flat design Very flat design Very flat design Large switching current range Large switching current range Large switching current range Component assembly under the relay Large excitation possible voltage range Component assembly under the relay possible Component assembly under the relay possible Small dimensions SGR 282 ZK SGR 282 ZK Variants Overmolded coil construction also suitable for applications in the ATEX-area Overmolded coil construction also suitable for applications in the ATEX-area High contact reliability High contact reliability Low coil power High contact reliability Number of Contacts 2 3 4 6 3 3 4 6 2/2 2 Contact Material AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi Contact types (output contacts) Single contact with notched crown Single contact with notched crown Single contact with notched crown Single contact with notched crown Single contact with notched crown Single contact with notched crown Single contact with notched crown Single contact with notched crown Single contact with notched crown Single contact with notched crown Coil voltage 3 VDC 60 VDC 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 110 VDC 5 VDC 110 VDC 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 110 VDC Coil Power1 200 mW 270 mW 400 mW 600 mW 330 mW 500 mW 440 mW 660 mW 700 mW 600 mW 700 mW 660 mW 700 mW 700 mW Switching 3 mA - 6 A current range 3 mA - 6 A 3 mA - 6 A 3 mA - 6 A 3 mA - 6 A 3 mA - 10 A 3 mA - 8 A 3 mA - 8 A 4 mA - 8 A 4 mA - 8 A Test voltage open contact 1 500 Vrms 1 500 Vrms 1 500 Vrms 1 500 Vrms 1 500 Vrms 1 500 Vrms 1 500 Vrms 1 500 Vrms 1 500 Vrms 1 500 Vrms Test voltage between contacts 5 000 Vrms 4 000 Vrms 4 000 Vrms 4 000 Vrms 4 000 Vrms 4 000 Vrms 4 000 Vrms 4 000 Vrms 4 000 Vrms 4 000 Vrms 2 500 Vrms 2 500 Vrms 4 000 Vrms 4 000 Vrms 4 000 Vrms 5 000 Vrms 5 000 Vrms Test voltage Coil/Contact 4 000Vrms 2 500 Vrms 2 500 Vrms (SIS222, SIS312 Var 2) 2 500Vrms (SIS312) Protection class RT III RT III RT III RT III RT III RT II RT II RT II RT II RT II Dimensions in mm (external) L29,2 B16,6 H16,5 L29,2 B16,6 H16,5 L48 B16,6 H16,5 L48 B16,6 H16,5 L29,2 B16,6 H13 L33,7 B29,4 H10,9 L41 B29,4 H10,9 L53,6 B33,5 H10,9 L30,2 B12,7 H25,6 L30,2 B12,7 H25,6 Approval UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV Accessories - - - - - Page 6 Page 8 Page 10 Page 12 Page 14 Page 7 Page 9 Page 11 Page 13 1 reference temperature of 20C 2between the left and right contact side 3 between the control contacts ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 4 5 - - - Page 32 Page 33 Page 32 Page 33 Page 15 Page 16 Page 17 Page 18 Page 19 between control and output contacts between the output contacts (c) Copyright 04/2018 Product Overview Relays with forcibly guided contacts SIM 2 SIM 3 SIM 4 Overmolded coil construction also suitable for applications in the ATEX-area Overmolded coil construction also suitable for applications in the ATEX-area Overmolded coil construction also suitable for applications in the ATEX-area Extremely high levels of air and creepage distances Extremely high levels of air and creepage distances Extremely high levels of air and creepage distances SLR 4 SIR 4 / SIR 4 SEN Powerful Powerful Very compact design Compact design High contact reliability High contact reliability Low coil power with sensitive coil Large coil working range with sensitive coil SIR 4 P Extremely powerful For high peak current loads Compact design High contact reliability SIR 6 / SIR 6 SEN SIR 8 SIR 10 Powerful Powerful Powerful Compact design High contact reliability High contact reliability SIP 6 Extremely powerful Very high contact reliability Large coil working Large coil working For highest range range Low coil power loads in 3-phase Contact confiwith sensitive coil Contact confiapplications and guration freely guration freely DC loads Large coil working definable definable range with sensitive coil High contact reliability Contact configuration freely definable 2 3 4 4 4 4 6 8 10 6 AgSnO2 AgSnO2 AgSnO2 AgSnO2 AgSnO2 AgSnO2 AgSnO2 AgSnO2 AgSnO2 AgSnO2 Crown contact Crown contact Crown contact Crown contact Crown contact Single contact Crown contact Crown contact Crown contact Single contact 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 220 VDC 3 VDC 220 VDC 3 VDC 220 VDC 500 mW 750 mW 1 000 mW 600 mW 360 mW 600 mW 750 mW 500 mW 750 mW 1 300 mW 1 300 mW 1 300 mW 10 mA - 8 A 10 mA - 8 A 10 mA - 8 A 10 mA - 10 A 10 mA - 10 A 5 mA - 12 A 10 mA - 10 A 10 mA - 10 A 10 mA - 10 A 5 mA - 16 A 1 500 Vrms 1 500 Vrms 1 500 Vrms 1 500 Vrms 1 500 Vrms 1 500 Vrms 1 500 Vrms 1 500 Vrms 1 500 Vrms 1 500 Vrms 4 000 Vrms 2 500 Vrms 4 000 Vrms 2 2 500 Vrms 4 000 Vrms 2 4 000 Vrms 3 4 000 Vrms 4 5 000 Vrms 5 2 500 Vrms 3 5 000 Vrms 4 4 000 Vrms 5 2 500 Vrms 3 5 000 Vrms 4 4 000 Vrms 5 2 500 Vrms 3 5 000 Vrms 4 4 000 Vrms 5 4 000 Vrms 4 000 Vrms 2 500 Vrms 3 5 000 Vrms 4 4 000 Vrms 5 5 000 Vrms 5 000 Vrms 5 000 Vrms 2 500 Vrms 2 500 Vrms 2 500 Vrms 2 500 Vrms 5 000 Vrms 2 500 Vrms 2 500 Vrms RT II RT II RT II RT II RT II RT II RT II RT II RT II RT II L27,4 B12,5 H26,2 L36,1 B12,5 H26,2 L36,1 B12,5 H26,2 L53,3 B33,4 H16,5 L46,4 B16 H30,7 L46,4 B16 H30,7 L58,9 B16 H30,7 L85,5 B20 H32 L85,5 B20 H32 L84,6 B20 H32 UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV - Page 34 Page 34 - Page 34 - - - - - Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 (c) Copyright 04/2018 SIS 2 Series Circuit Diagram (relay top view) -- PCB relay with forcibly guided contacts -- Protective separation between control and load circuit (leakage and creepage distances > 10 mm) -- IEC 61 810-3 type A -- Double and reinforced insulation between the contacts -- Contact mounting SIS112 1 NO / 1 NC -- Small external dimensions -- Nominal coil power 0,27 W -- Holding coil power 0,08 W -- Coils for railway applications according to EN 50 155 on request Dimensions 1,6 0,2 0,3 18,7 6 1 1,6 2,3 10 16,6 11 3,3 3,3 2,2 0,4 2,8* 0,4 O 1,3 15 7,7 29,2 2,3 4,2 2,3 [mm] Contact material AgCuNi+0,2-0,4 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1 500 VA Electr. Life AC1 (360 S / h) >90 000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Nominal current in mA 0,5 0,6 0,9 1,2 1,8 2,4 4,8 6,0 54,9 46,1 30,5 23,0 15,2 11,4 5,7 4,5 Resistance in Ohm at 20 C Drop-out voltage at 20 C Min. pick-up voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 3,5 4,2 6,3 8,4 12,6 16,8 33,6 42,0 1000 12 A2 11 SIS112 A1 -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2 500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >10 mm -- Test voltage 5 000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M 91 130 295 520 1180 2 100 8 350 13 100 10% 10% 10% 10% 10% 10% 13% 15% Mechanical endurance >10x106 operations Switching frequency, mechanical 15 Hz Response time (NO closed) typically 10 ms Drop-out time (NC closed) typically 3 ms Bounce time of NO contact typically 2 ms Bounce time of NC contact typically 15 ms Shock resistance 16 ms NO > 17g NC > 7g Vibration resistance NO > 7g (10-200 Hz) NC > 2g Resistance to short circuiting contacts 1 000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +85 C Thermal Resistance 55 K / W Temperature limit for coil 120 C Weight approx. 18 g Mounting position any Type of protection RT III Solder bath temperature 270C / 5 s DC 13: 24V 10 0,1 0,5 1 Switching Current (A) Product Key +41 81 303 54 00 3 4 5 6 7 8910 Load Limit Curve with Direct Current 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 150 200 250 1)Inductive load L/R 40 ms 2)Resistive load Excitation Voltage Range 3,0 2,5 1 2,0 0,5 UB UN 0 2 0 20 40 60 Ambient Temperature C 80 100 1)Max. excitation voltage with contact load: 4 A 2)Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. none available ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland 2 Maximal switching characteristics (DIN EN 60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 1,0 Options, Accessories AC 15: 230V 50 Tests, Regulations, Standards UL File E188 953 Sec. 5 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 AC 1:230V 100 1,5 Approvals DC 1: 24V 500 **without spark suppression SIS 1 1 2 24VDC 6 5000 Additional Data Contact Data 5 6 9 12 18 24 48 60 24 Current (A) 1,6 3,3 16,5 0,2 1,6 10000 23 Insulation Data 16,6 29,2 Contact Lifetime for NO Contact Operations x 1000 Relay Key Data Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 SIS 2 sensitive Series Circuit Diagram (relay top view) -- PCB relay with forcibly guided contacts -- Protective separation between control and load circuit (leakage and creepage distances > 10 mm) -- IEC 61 810-3 type A -- Double and reinforced insulation between the contacts -- Contact mounting SIS112 1 NO / 1 NC -- Small external dimensions -- Nominal coil power 0,2 W -- Holding coil power 0,04 W 10000 18,7 6 2,3 15 7,7 29,2 2,3 1 1,6 10 16,6 11 3,3 3,3 2,2 0,4 O 1,3 2,3 4,2 SIS112SEN A1 [mm] -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >10 mm -- Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Contact material AgCuNi+0,2-0,4 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1 500 VA Electr. Life AC1 (360 S / h) >90 000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA 3,0 3,3 4,5 5,0 6,0 9,0 12,0 24,0 48,0 60,0 2,25 2,47 3,37 3,75 4,50 6,75 9,00 18,00 36,00 45,00 0,30 0,33 0,45 0,50 0,60 0,90 1,20 2,40 4,80 6,00 66,6 60,6 44,5 40,0 33,3 22,2 16,6 8,3 4,1 3,3 Resistance in Ohm at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 45,0 54,4 101,0 125,0 180,0 405,0 720,0 2 880,0 11 520,0 18 000,0 10% 10% 10% 10% 10% 10% 10% 10% 13% 13% Mechanical endurance >10x106 operations Switching frequency, mechanical 12 Hz Response time (NO closed) typically 15 ms Drop-out time (NC closed) typically 5 ms Bounce time of NO contact typically 2 ms Bounce time of NC contact typically 15 ms Shock resistance 16 ms NO > 17g NC > 7g Vibration resistance NO > 7g (10-200 Hz) NC > 2g Resistance to short circuiting contacts 1 000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +85 C Thermal Resistance 55 K / W Temperature limit for coil 120 C Weight approx. 18 g Mounting position any Type of protection RT III Solder bath temperature 270 C / 5 s AC 1:230V 100 AC 15: 230V 50 DC 13: 24V 10 0,1 0,5 1 Switching Current (A) 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 200 250 4,0 3,5 1 3,0 1 2,5 UL File E188 953 Sec. 5 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 1,5 1,0 UB UN 2 2 0,5 0 -10 10 30 Ambient Temperature C 50 70 1)Max. excitation voltage with contact load: 4 A 2)Min. excitation voltage (guaranteed values) without previous operation Product Key +41 81 303 54 00 150 Excitation Voltage Range 2,0 ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland 100 1)Inductive load L/R 40 ms 2)Resistive load Approvals SIS 1 1 2 24VDC SEN 50 Voltage (VDC) Tests, Regulations, Standards none available 3 4 5 6 7 8910 2 0,1 0 **without spark suppression Options, Accessories 2 Load Limit Curve with Direct Current Additional Data Contact Data DC 1: 24V 500 Maximal switching characteristics (DIN EN 60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Current (A) 0,3 2,8* 0,4 11 Insulation Data 1,6 0,2 1,6 3,3 16,5 0,2 1,6 5000 1000 12 A2 16,6 23 24 Dimensions 29,2 Contact Lifetime for NO Contact Operations x 1000 Relay Key Data sensitive coil Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. (c) Copyright 04/2018 7 SIS 3 Series Circuit Diagram (relay top view) Dimensions 29,2 25,2 2 0,2 0,3 0,4 6 2,3 1 0,2 10 O 1,3 2,3 4,2 6,5 8,5 7,7 29,2 2,3 [mm] 3,3 16,6 11 3,3 3,3 6,5 12,2 2,8* 0,4 2,2 12 A2 11 SIS212 A1 -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >5,5 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Contact Data Additional Data Contact material AgCuNi+0,2-0,4 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1 500 VA Electr. Life AC1 (360 S / h) >90 000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA Mechanical endurance >10x106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 10 ms Drop-out time (NC closed) typically 3 ms Bounce time of NO contact typically 2 ms Bounce time of NC contact typically 15 ms Shock resistance 16 ms NO > 17g NC > 10g Vibration resistance NO > 7g (10-200 Hz) NC > 3g Resistance to short circuiting contacts 1 000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +85C Thermal Resistance 55 K / W Temperature limit for coil 120C Weight approx. 20 g Mounting position any Type of protection RT III Solder bath temperature 270C / 5 s *Guided values 5 9 12 18 24 48 60 110 3,5 6,3 8,4 12,6 16,8 33,6 42,0 77,0 0,5 0,9 1,2 1,8 2,4 4,8 6,0 11,0 120,0 66,6 50,0 33,3 25,0 12,5 10,0 5,4 Resistance in Ohm at 20 C Nominal current in mA Drop-out voltage at 20 C Min. pick-up voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 41,5 135,0 240,0 540,0 960,0 3 840,0 6 000,0 20 150,0 10% 10% 10% 10% 10% 10% 13% 15% **without spark suppression UL File E188 953 Sec. 5 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 Options, Accessories +41 81 303 54 00 DC 1: 24V 500 AC 1:230V 100 AC 15: 230V 50 DC 13: 24V 10 0,1 0,5 1 Switching Current (A) 2 3 4 5 6 7 8910 Maximal switching characteristics (DIN EN 60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each Load Limit Curve with Direct Current 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 150 Voltage (VDC) 200 250 1)Inductive load L/R 40 ms 2)Resistive load Excitation Voltage Range 3,0 2,5 2,0 1 0,5 UB UN 0 2 0 20 40 60 Ambient Temperature C 80 100 1)Max. excitation voltage with contact load: 4 A 2)Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. Product Key SIS 2 1 2 24VDC 1000 1,0 Approvals ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland 5000 1,5 Tests, Regulations, Standards none available 8 10000 23 24 Insulation Data 16,6 16,5 0,2 2 33 34 -- Contact Lifetime for NO Contacts Operations x 1000 -- PCB relay with forcibly guided contacts -- Protective separation between control and load circuit (leakage and creepage distances >8 mm) -- IEC 61 810-3 type A -- Double and reinforced insulation between the contacts -- Contact mounting SIS212 2 NO / 1 NC -- Small external dimensions -- Nominal coil power 0,6 W -- Holding coil power 0,18 W -- Coils for railway applications according to EN 50 155 on request Current (A) Relay Key Data Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 SIS 3 sensitive Series Circuit Diagram (relay top view) -- PCB relay with forcibly guided contacts -- Protective separation between control and load circuit (leakage and creepage distances >8 mm) -- IEC 61 810-3 type A -- Double and reinforced insulation between the contacts -- Contact mounting SIS212 2 NO / 1 NC -- Small external dimensions -- Nominal coil power 0,4 W -- Holding coil power 0,14 W -- Coils for railway applications according to EN 50 155 on request Dimensions 29,2 25,2 2 0,2 0,3 0,4 6 2,3 1 0,2 10 O 1,3 6,5 8,5 7,7 29,2 2,3 Contact material AgCuNi+0,2-0,4 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1 500 VA Electr. Life AC1 (360 S / h) >90 000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Nominal current in mA 0,5 0,6 0,9 1,2 1,8 2,4 4,8 6,0 80,0 66,6 44,5 33,3 22,2 16,6 8,3 6,6 Resistance in Ohm at 20 C Drop-out voltage at 20 C Min. pick-up voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 3,75 4,50 6,75 9,00 13,50 18,00 36,00 45,00 12 11 SIS212SEN A1 -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance 5,5 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M 1000 62,5 90,0 202,0 360,0 810,0 1 440,0 5 750,0 9 000,0 10% 10% 10% 10% 10% 10% 13% 15% Mechanical endurance >10x106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 10 ms Drop-out time (NC closed) typically 3 ms Bounce time of NO contact typically 2 ms Bounce time of NC contact typically 15 ms Shock resistance 16 ms NO > 17g NC > 10g Vibration resistance NO > 7g (10-200 Hz) NC > 3g Resistance to short circuiting contacts 1 000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +85C Thermal Resistance 55 K / W Temperature limit for coil 120C Weight approx. 20 g Mounting position any Type of protection RT III Solder bath temperature 270C / 5 s **without spark suppression DC 1: 24V 500 AC 1:230V 100 AC 15: 230V 50 DC 13: 24V 10 0,1 0,5 1 Switching Current (A) Approvals UL File E188 953 Sec. 5 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 Options, Accessories 3 4 5 6 7 8910 Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each Load Limit Curve with Direct Current 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 150 200 250 60 80 100 1)Inductive load L/R 40 ms 2)Resistive load Excitation Voltage Range 3,0 2,5 1 2,0 1,5 1,0 Tests, Regulations, Standards 2 Maximal switching characteristics (DIN EN 60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Additional Data Contact Data 5 6 9 12 18 24 48 60 5000 Current (A) 2,3 4,2 [mm] 3,3 16,6 11 3,3 3,3 6,5 12,2 2,8* 0,4 2,2 10000 23 24 Insulation Data 16,6 16,5 0,2 2 33 34 A2 Contact Lifetime for NO Contacts Operations x 1000 Relay Key Data 0,5 UB UN 0 2 0 20 40 Ambient Temperature C 1)Max. excitation voltage with contact load: 4 A 2)Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. none available Product Key SIS 2 1 2 24VDC SEN ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 sensitive coil Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 9 SIS 4 Series Circuit Diagram (relay top view) Dimensions 0,2 2,3 0,3 2,8 0,4 5 7 O1,3 2,3 10 3,3 SIS312 KV2 0,2 16,5 0,2 48 18,7 11 0,2 2,8 0,3 13 4 13 15 8,7 5 2,3 2 6,5 6,5 18,7 12 2,3 O1,3 11 16,5 0,2 SIS312 2 4 6,5 6,5 15 13,7 10 8,5 13,7 48 0,4 [mm] 3,3 2,3 2,3 2,3 10 8,5 12 O1,3 4 6,5 13 1 2,8 0,3 16,7 11 3,3 0,4 2 6,5 2,3 16,5 0,2 SIS222 2,3 Contact Data Contact material AgCuNi+0,2-0,4 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1 500 VA Electr. Life AC1 (360 S / h) >90 000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values 0,5 0,9 1,2 1,8 2,4 4,8 6,0 11,0 100,0 56,2 42,1 28,1 20,8 10,4 8,3 4,5 12 11 22 21 13 14 A2 SIS222 A1 A2 SIS312 12 A1 A2 50 160 285 640 1150 4 600 7 200 24 200 10% 10% 10% 10% 10% 10% 13% 15% 5000 23 24 21 10000 33 33 34 34 11 SIS312 KV2 A1 -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >5,5 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M 1000 Mechanical endurance >10x106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 15 ms Drop-out time** (NC closed) typically 5 ms Bounce time of NO contact typically 2 ms Bounce time of NC contact typically 15 ms Shock resistance 16 ms NO > 10g NC > 10g Vibration resistance NO > 10g (10-200 Hz) NC > 4g Resistance to short circuiting contacts 1 000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +85C Thermal Resistance 45 K / W Temperature limit for coil 120C Weight approx. 30 g Mounting position any Type of protection RT III Solder bath temperature 270C / 5 s DC 1: 24V 500 AC 1:230V 100 AC 15: 230V 50 DC 13: 24V 10 0,1 0,5 1 Switching Current (A) UL File E188 953 Sec. 5 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 Options, Accessories Load Limit Curve with Direct Current 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 1)Inductive load L/R 40 ms 2)Resistive load 150 200 60 80 Excitation Voltage Range 3,0 2,5 1 2,0 1,5 0,5 UB UN 0 2 0 20 40 Ambient Temperature C +41 81 303 54 00 100 1)Max. excitation voltage with contact load: 4 A 2)Min. excitation voltage (guaranteed values) without previous operation Product Key ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland 250 Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. none available SIS 3 1 2 24VDC KV2 3 4 5 6 7 8910 Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each 3 contacts with 4 A each 1,0 Approvals 2 Maximal switching characteristics (DIN EN 60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Additional Data Tests, Regulations, Standards Resistance in Ohm at 20 C Nominal current in mA Min. pick-up voltage at 20 C 10 Drop-out voltage at 20 C Nominal voltage VDC 3,5 6,3 8,4 12,6 16,8 33,6 42,0 77,0 22 43 44 **without spark suppression Standard coils for direct current (other voltages on request) 5 9 12 18 24 48 60 110 33 34 43 44 Insulation Data 16,6 48 43 44 Contact Lifetime for NO Contacts Operations x 1000 -- PCB relay with forcibly guided contacts -- Protective separation between control and load circuit (leakage and creepage distances >8 mm) -- IEC 61 810-3 type A -- Double and reinforced insulation between the contacts -- Contact mounting SIS312 3 NO / 1 NC SIS222 2 NO / 2 NC -- Small external dimensions -- Nominal coil power 0,5 W -- Holding coil power 0,15 W -- Coils for railway applications according to EN 50 155 on request Current (A) Relay Key Data Contact variant Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 SIS 4 sensitive Series Circuit Diagram (relay top view) Dimensions 2,3 2,3 18,7 5 7 O1,3 2,3 10 13 11 3,3 0,3 2,3 0,4 0,2 SIS312 KV2 2,8 16,5 0,2 48 2 4 13 15 8,7 5 2,3 2 6,5 6,5 18,7 12 2,3 O1,3 11 2,8 0,3 3,3 2,3 0,2 SIS312 0,4 [mm] 4 6,5 6,5 15 13,7 10 8,5 13,7 48 16,5 0,2 2,3 0,2 8,5 12 O1,3 4 6,5 13 1 2,8 0,3 16,7 11 3,3 0,4 2 6,5 10 16,5 0,2 SIS222 2,3 Contact Data Contact material AgCuNi+0,2-0,4 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1 500 VA Electr. Life AC1 (360 S / h) >90 000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values 0,3 0,3 0,5 0,5 0,6 1,2 2,4 6,0 111,0 100,0 73,7 66,6 55,5 27,9 13,8 5,5 22 11 21 13 14 SIS222 SEN 12 11 A1 A2 A1 A2 A2 SIS312 SEN A1 SIS312 SEN KV2 -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >5,5 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M 10% 10% 10% 10% 10% 10% 10% 10% 1000 Mechanical endurance >10x106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 20 ms Drop-out time** (NC closed) typically 4 ms Bounce time of NO contact typically 2 ms Bounce time of NC contact typically 15 ms Shock resistance 16 ms NO > 10g NC > 10g Vibration resistance NO > 10g (10-200 Hz) NC > 4g Resistance to short circuiting contacts 1 000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +85C Thermal Resistance 45 K / W Temperature limit for coil 120C Weight approx. 30 g Mounting position any Type of protection RT III Solder bath temperature 270C / 5 s DC 1: 24V 500 AC 1:230V 100 AC 15: 230V 50 DC 13: 24V 10 0,1 0,5 1 Switching Current (A) UL File E188 953 Sec. 5 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 Options, Accessories 3 4 5 6 7 8910 Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each 3 contacts with 4 A each Load Limit Curve with Direct Current 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 1)Inductive load L/R 40 ms 2)Resistive load 150 200 250 Excitation Voltage Range 3,0 1 2,5 2,0 1,5 2 1,0 Approvals 2 Maximal switching characteristics (DIN EN 60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Additional Data Tests, Regulations, Standards 27 33 61 75 108 430 1 730 10 800 5000 23 24 22 10000 33 33 34 34 21 12 43 44 **without spark suppression Resistance in Ohm at 20 C Nominal current in mA 2,3 2,5 3,4 3,8 4,5 9,0 18,0 45,0 Drop-out voltage at 20 C Min. pick-up voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 3,0 3,3 4,5 5,0 6,0 12,0 24,0 60,0 33 34 43 44 Insulation Data 16,6 48 43 44 Contact Lifetime for NO Contacts Operations x 1000 -- PCB relay with forcibly guided contacts -- Protective separation between control and load circuit (leakage and creepage distances >8 mm) -- IEC 61 810-3 type A -- Double and reinforced insulation between the contacts -- Contact mounting SIS312 3 NO / 1 NC SIS222 2 NO / 2 NC -- Small external dimensions -- Nominal coil power 0,33 W -- Holding coil power 0,08 W -- Coils for railway applications according to EN 50 155 on request Current (A) Relay Key Data 0,5 UB UN 0 0 20 40 60 80 100 Ambient Temperature C 1)Max. excitation voltage with contact load: 4 A 2)Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. none available Product Key SIS 3 1 2 24VDC SEN KV2 ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 Contact variant sensitive coil Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 11 SIS 6 Series Circuit Diagram (relay top view) Dimensions 48 0,2 16,5 0,2 16,6 0,3 2,8 0,4 3,3 2 6,5 6,5 10,2 8,5 5 7 2,3 2,3 [mm] 10 11 O1,3 4 6,5 6,5 6,5 8,5 8,7 5 1 2,3 Contact Data Contact material AgCuNi + 0,2 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1 500 VA Electr. Life AC1 (360 S / h) >90 000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values 0,5 0,9 1,2 1,8 2,4 4,8 6,0 11,0 133,0 73,7 55,8 37,1 29,7 13,9 11,1 6,0 Resistance in Ohm at 20 C 3,5 6,3 8,4 12,6 16,8 33,6 42,0 77,0 Nominal current in mA Min. pick-up voltage at 20 C 5 9 12 18 24 48 60 110 Drop-out voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 37,5 122,0 215,0 485,0 860,0 3 450,0 5 400,0 18 300,0 10% 10% 10% 10% 10% 10% 13% 15% 64 54 10000 53 5000 43 44 32 1000 31 22 21 13 14 A2 Contact Lifetime for NO Contacts 63 Operations x 1000 -- PCB relay with forcibly guided contacts -- Protective separation between control and load circuit (leakage and creepage distances >8 mm) -- IEC 61 810-3 type A -- Double and reinforced insulation between the contacts -- Contact mounting SIS422 4 NO / 2 NC -- Small external dimensions -- Nominal coil power approx. 0,66 W -- Holding coil power 0,20 W -- Coils for railway applications according to EN 50 155 on request SIS422 A1 Insulation Data -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >5,5 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M **without spark suppression UL File E188 953 Sec. 5 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 none available +41 81 303 54 00 10 0,1 0,5 1 Switching Current (A) 2 3 4 5 6 7 8910 Load Limit Curve with Direct Current 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 1)Inductive load L/R 40 ms 2)Resistive load 150 200 60 80 250 Excitation Voltage Range 3,0 2,5 1 2,0 0,5 UB UN 0 2 0 20 40 100 Ambient Temperature C 1)Max. excitation voltage with contact load: 4 A 2)Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. Product Key ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland DC 13: 24V 1,0 Approvals Options, Accessories 12 AC 15: 230V 50 1,5 Tests, Regulations, Standards SIS 4 2 2 24VDC AC 1:230V 100 Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each 3 contacts with 4 A each 4 contacts with 3 A each Additional Data Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 15 ms Drop-out time** (NC closed) typically 5 ms Bounce time of NO contact typically 2 ms Bounce time of NC contact typically 15 ms Shock resistance 16 ms NO > 10g NC > 9g Vibration resistance NO > 10g (10-200 Hz) NC > 3g Resistance to short circuiting contacts 1 000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +85C Thermal Resistance 45 K / W Temperature limit for coil 120C Weight approx. 35 g Mounting position any Type of protection RT III Solder bath temperature 270C / 5 s DC 1: 24V 500 Maximal switching characteristics (DIN EN 60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Current (A) Relay Key Data Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 SIS 6 sensitive Series Circuit Diagram (relay top view) Dimensions 48 0,2 16,5 0,2 16,6 2,8 0,3 2 6,5 6,5 10,2 8,5 5 2,3 7 4 6,5 6,5 6,5 8,5 8,7 5 1 2,3 [mm] 10 O1,3 11 3,3 0,4 2,3 Contact Data Contact material AgCuNi + 0,2 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1 500 VA Electr. Life AC1 (360 S / h) >90 000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values 0,3 0,3 0,5 0,5 0,6 0,9 1,2 2,4 4,8 6,0 147,0 134,0 97,8 88,9 73,6 48,9 36,9 18,4 9,2 7,3 Resistance in Ohm at 20 C Nominal current in mA 2,3 2,5 3,4 3,8 4,5 6,8 9,0 18,0 36,0 45,0 Drop-out voltage at 20 C 3,0 3,3 4,5 5,0 6,0 9,0 12,0 24,0 48,0 60,0 Min. pick-up voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 20,4 24,5 46,0 56,2 81,5 184,0 325,0 1 300,0 5 200,0 8 150,0 10% 10% 10% 10% 10% 10% 10% 10% 13% 13% 64 10000 53 54 5000 43 44 32 1000 31 22 21 13 14 A2 Contact Lifetime for NO Contacts 63 Operations x 1000 -- PCB relay with forcibly guided contacts -- Protective separation between control and load circuit (leakage and creepage distances >8 mm) -- IEC 61 810-3 type A -- Double and reinforced insulation between the contacts -- Contact mounting SIS422 4 NO / 2 NC -- Small external dimensions -- Nominal coil power 0,44 W -- Holding coil power 0,10 W -- Coils for railway applications according to EN 50 155 on request SIS422SEN A1 Insulation Data -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >5,5 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M **without spark suppression UL File E188 953 Sec. 5 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 Options, Accessories none available 10 0,1 0,5 1 Switching Current (A) 2 3 4 5 6 7 8910 Load Limit Curve with Direct Current 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 1)Inductive load L/R 40 ms 2)Resistive load 150 200 60 80 250 Excitation Voltage Range 3,0 2,5 2,0 1 2 0,5 UB UN 0 0 20 40 100 Ambient Temperature C 1)Max. excitation voltage with contact load: 4 A 2)Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. Product Key +41 81 303 54 00 DC 13: 24V 1,0 Approvals ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland AC 15: 230V 50 1,5 Tests, Regulations, Standards SIS 4 2 2 24VDC SEN AC 1:230V 100 Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each 3 contacts with 4 A each 4 contacts with 3 A each Additional Data Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 20 ms Drop-out time** (NC closed) typically 4 ms Bounce time of NO contact typically 2 ms Bounce time of NC contact typically 15 ms Shock resistance 16 ms NO > 10g NC > 9g Vibration resistance NO > 10g (10-200 Hz) NC > 3g Resistance to short circuiting contacts 1 000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +85C Thermal Resistance 45 K / W Temperature limit for coil 120C Weight approx. 35 g Mounting position any Type of protection RT III Solder bath temperature 270C / 5 s DC 1: 24V 500 Maximal switching characteristics (DIN EN 60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Current (A) Relay Key Data sensitive coil Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 13 SISF 3 Series Preliminary Data Sheet Circuit Diagram (relay top view) -- PCB relay with forcibly guided contacts -- Protective separation between control and load circuit (leakage and creepage distances >8 mm) -- IEC 61 810-3 type A -- Double and reinforced insulation between the contacts -- Contact mounting SIS212 2 NO / 1 NC -- Small external dimensions -- Nominal coil power 0,7 W -- Holding coil power 0,25 W -- Coils for railway applications according to EN 50 155 on request Dimensions 2 0,2 13 0,2 2 0,4 6,5 12,2 6 1 0,2 2,3 10 O 1,3 2,3 4,2 6,5 8,5 7,7 29,2 2,3 [mm] 3,3 16,6 11 3,3 3,3 2,2 0,3 2,8 0,4 Contact material AgCuNi+0,2-0,4 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1 500 VA Electr. Life AC1 (360 S / h) >90 000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values 0,5 0,9 1,2 1,8 2,4 4,8 6,0 11,0 120,0 66,6 50,0 33,3 25,0 12,5 10,0 5,4 Resistance in Ohm at 20 C Nominal current in mA Drop-out voltage at 20 C Min. pick-up voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 3,5 6,3 8,4 12,6 16,8 33,6 42,0 77,0 1000 12 11 SISF212 -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >5,5 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M 35 115 205 460 820 3 280 5 100 17250 10% 10% 10% 10% 10% 10% 13% 15% Mechanical endurance >10x106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 10 ms Drop-out time (NC closed) typically 3 ms Bounce time of NO contact typically 2 ms Bounce time of NC contact typically 15 ms Shock resistance 16 ms NO > 17g NC > 10g Vibration resistance NO > 7g (10-200 Hz) NC > 3g Resistance to short circuiting contacts 1 000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +85C Thermal Resistance 55 K / W Temperature limit for coil 120C Weight approx. 20 g Mounting position any Type of protection RT III Solder bath temperature 270C / 5 s AC 1:230V 100 3 4 5 6 7 8910 Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each Load Limit Curve with Direct Current 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 150 Voltage (VDC) 200 250 1)Inductive load L/R 40 ms 2)Resistive load Excitation Voltage Range 3,0 2,0 1,5 UL File E188 953 Sec. 5 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 1,0 0,5 UB UN 0 1 2 0 20 40 60 Ambient Temperature C 80 100 1)Max. excitation voltage with contact load: 4 A 2)Min. excitation voltage (guaranteed values) without previous operation Product Key +41 81 303 54 00 2 Maximal switching characteristics (DIN EN 60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Approvals ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland DC 13: 24V 10 0,1 0,5 1 Switching Current (A) Tests, Regulations, Standards none available AC 15: 230V 50 2,5 Options, Accessories DC 1: 24V 500 **without spark suppression SISF2 1 2 24VDC 14 A1 Additional Data Contact Data 5 9 12 18 24 48 60 110 5000 23 24 Insulation Data 16,6 10000 Current (A) 29,2 25,2 33 34 A2 Contact Lifetime for NO Contacts Operations x 1000 Relay Key Data Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. (c) Copyright 04/2018 SIF 3 Series Circuit Diagram (relay top view) Dimensions 33,7 5,1 7,6 2,2 3,1 2,9 15,8 10,5 6,4 18,2 * 3 1, O 7,6 1 4,2 [mm] * 20,8 5,3 3,1 4,8 * 3,1 7,5 7,5 1,8 * ** 21 23,2 4,2 4,2 0,5 1,5 15,4 4,2 3,1 23,2 1,2 3,1 * when SMD is placed underneath the relay, do not drill holes ** Open breathing hole Contact Data Contact material AgCuNi + 0,2 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 10 A AC1 2 500 VA Electr. Life AC1(360 S / h) approx. 100 000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 10 A Switching capacity range* 40 mW to 2500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values 3,5 8,4 12,6 14,0 16,8 33,6 42,0 77,0 23 24 11 12 A2 A1 SIF212 0,5 1,2 1,8 2,0 2,4 4,8 6,0 11,0 Resistance in Ohm at 20 C Nominal current in mA 120,0 50,0 33,3 30,0 25,0 12,5 10,0 5,4 41,6 240,0 540,0 665,0 960,0 3 840,0 6 000,0 20 165,0 10% 10% 10% 10% 10% 10% 13% 15% 1000 -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >5,5 mm -- Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Additional Data Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 12 ms Drop-out time (NC closed) typically 5 ms Bounce time of NO contact typically 1,5 ms Bounce time of NC contact typically 15 ms Shock resistance 16 ms NO > 15g NC > 6g Vibration resistance NO > 10g (10-200 Hz) NC > 2g Resistance to short circuiting contacts NO 1 000 A SCPD 10 A gG / gL (pre-fuse) Resistance to short circuiting contacts NC 1 000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 60 K / W Temperature limit for coil 120C Weight approx. 18 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s AC 1:230V 100 DC 13: 24V 10 0,1 5,0 10 Load Limit Curve with Direct Current 10 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 2 0,1 50 100 0 Voltage (VDC) 1)Inductive load L/R 40 ms 2)Resistive load 200 60 80 250 3,0 2,5 1,5 1 1,0 UL File E188 953 Sec. 6 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 150 Excitation Voltage Range Tests, Regulations, Standards 0,5 UB UN 0 2 0 20 40 Ambient Temperature C 100 1)Max. excitation voltage with contact load: 6 A 2)Min. excitation voltage (guaranteed values) without previous operation Options, Accessories none available Product Key +41 81 303 54 00 1,0 Maximal contact load at AC 1 with 230 V: 2 contacts with 8 A each 2,0 ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland 0,5 Maximal switching characteristics (DIN EN 60947-5-1) AC 1: 250 V / 10 A AC 15: 230 V / 5 A DC 1: 24 V / 10 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 **without spark suppression SIF 2 1 2 24VDC DC 1: 24V AC 15: 230V Switching Current (A) Approvals Drop-out voltage at 20 C Min. pick-up voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 5 12 18 20 24 48 60 110 10000 34 Insulation Data 29,4 10,9 1,5 33 Contact Lifetime for NO Contacts Operations x 1000 -- PCB relay with forcibly guided contacts -- Protective separation between coil and contacts (>5,5mm) and contacts side by side (>5,5mm) -- IEC 61 810-3 Type A -- Double and reinforced insulation between the contacts -- SMD placement under relay possible -- Contact mounting SIF212 2 NO / 1 NC -- Small overall height: Only 10,9 mm -- Nominal coil power 0,60 W -- Holding coil power 0,18 W -- Coils for railway applications according to EN 50 155 on request Current (A) Relay Key Data Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 15 SIF 4 Series Circuit Diagram (relay top view) 43 -- PCB relay with forcibly guided contacts -- Protective separation between coil and contacts (>5,5 mm) and contacts side by side (>5,5mm) -- IEC 61 810-3 type A -- Double and reinforced insulation -- SMD placement under relay possible -- Contact mounting SIF222 2 NO / 2 NC SIF312 3 NO / 1 NC -- Small height: only 10,9 mm -- Nominal coil power 0,70 W -- Holding coil power 0,21 W -- Coils for railway applications according to EN 50 155 on request Dimensions 3,1 29,4 23,2 4,2 1 4,2 7,5 7,5 7,5 1,6 15,8 10,5 18,2 6,4 2,9 21 23,2 4,2 3,1 15,4 3,1 1,2 2,2 10,9 5,1 1,6 0,5 1,5 33 34 21 22 11 12 A2 A1 44 33 34 23 24 11 12 A2 SIF222 A1 O1,3 [mm] 10000 SIF312 Insulation Data 41 37,8 1,5 7,6 44 Contact Lifetime for NO Contacts 43 Operations x 1000 Relay Key Data -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >5,5 mm -- Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M * when SMD is placed underneath the relay, do not drill holes ** Open breathing hole Contact Data Contact material AgCuNi+0,2 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 8 A AC1 2 000 VA Electr. Life AC1(360 S / h) approx. 100 000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 8 A Switching capacity range* 40 mW to 2000 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values 5 12 18 20 24 48 60 110 3,5 8,4 12,6 14,0 16,8 33,6 42,0 77,0 16 0,5 1,2 1,8 2,0 2,4 4,8 6,0 11,0 140,0 58,5 39,1 35,0 29,2 14,6 11,7 6,3 35,7 205,0 460,0 570,0 820,0 3 280,0 5 100,0 17 250,0 10% 10% 10% 10% 10% 10% 13% 15% Mechanical endurance >10x10 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 12 ms Drop-out time** (NC closed) typically 5 ms Bounce time of NO contact typically 1,5 ms Bounce time of NC contact typically 15 ms Shock resistance 16 ms NO > 15g NC > 5g Vibration resistance NO > 10g (10-200 Hz) NC > 2g Resistance to short circuiting contacts NO 1 000 A SCPD 10 A gG / gL (pre-fuse) Resistance to short circuiting contacts NC 1 000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 60 K / W Temperature limit for coil 120C Weight approx. 20 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s 10 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 10 2 0,1 50 100 0 Voltage (VDC) 150 200 60 80 250 1)Inductive load L/R 40 ms 2)Resistive load Excitation Voltage Range 3,0 2,5 1 1,0 UL File E188 953 Sec. 6 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 Options, Accessories 0,5 UB UN 0 2 0 20 40 100 Ambient Temperature C 1)Max. excitation voltage with contact load: 5 A 2)Min. excitation voltage (guaranteed values) without previous operation none available Product Key +41 81 303 54 00 5,0 1,5 Approvals ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland 10 0,1 0,5 1,0 Switching Current (A) 2,0 Tests, Regulations, Standards SIF 3 1 2 24VDC DC 13: 24V Load Limit Curve with Direct Current Additional Data **without spark suppression Resistance in Ohm at 20 C Nominal current in mA Drop-out voltage at 20 C Min. pick-up voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) AC 1:230V 100 Maximal contact load at AC 1 with 230 V: 2 contacts with 8A each 3 contacts with 6A each Current (A) 5,1 3,1 4,8 4,2 3,1 28,3 DC 1: 24V AC 15: 230V Maximal switching characteristics (DIN EN 60947-5-1) AC 1: 250 V / 8 A AC 15: 230 V / 5 A DC 1: 24 V / 8 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 6 7,6 1000 Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 SIF 6 Series Circuit Diagram (relay top view) -- PCB relay with forcibly guided contacts -- Protective separation between coil and contacts (>5,5 mm) and contacts side by side (>5,5mm) -- IEC 61 810-3 type A -- Double and reinforced insulation -- SMD placement under relay possible -- Contact mounting SIF422 4 NO / 2 NC -- Small height: only 10,9 mm -- Nominal coil power 0,66 W -- Holding coil power 0,20 W -- Coils for railway applications according to EN 50 155 on request Dimensions 1,2 2,2 3,3 * 4,1 3,1 O1,3 * * [mm] 1,5 3,1 1,6 ** 1,5 0,5 15,8 * ** 33,5 30,4 1,6 15,4 7,5 7,5 1 15,8 15,8 * when SMD is placed underneath the relay, do not drill holes ** Open breathing hole Contact Data Contact material AgCuNi + 0,2 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 8 A AC1 2 000 VA Electr. Life AC1(360 S / h) approx. 100 000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 8 A Switching capacity range* 40 mW to 2000 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values 3,5 8,4 12,6 14,0 16,8 33,6 42,0 77,0 0,5 1,2 1,8 2,0 2,4 4,8 6,0 11,0 133,3 55,8 38,9 33,3 27,5 13,8 11,1 6,0 Resistance in Ohm at 20 C Nominal current in mA Drop-out voltage at 20 C Min. pick-up voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 5 12 18 20 24 48 60 110 12 63 33 43 11 21 A2 64 44 22 A1 SIF422 10000 37,5 215,0 490,0 600,0 870,0 3 460,0 5 400,0 18 300,0 10% 10% 10% 10% 10% 10% 13% 15% -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >5,5 mm -- Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Additional Data Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 20 ms Drop-out time** (NC closed) typically 8 ms Bounce time of NO contact typically 1,5 ms Bounce time of NC contact typically 15 ms Shock resistance 16 ms NO > 10g NC > 6g Vibration resistance NO > 10g (10-200 Hz) NC > 2g Resistance to short circuiting contacts NO 1 000 A SCPD 10 A gG / gL (pre-fuse) Resistance to short circuiting contacts NC 1 000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 47 K / W Temperature limit for coil 120C Weight approx. 35 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s AC 1:230V DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 150 Voltage (VDC) 1)Inductive load L/R 40 ms 2)Resistive load 200 250 Excitation Voltage Range 3,0 2,0 1 1,5 UL File E188 953 Sec. 6 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 Options, Accessories none available 1,0 0,5 UB UN 0 2 0 20 40 60 Ambient Temperature C 80 100 1)Max. excitation voltage with contact load: 5 A 2)Min. excitation voltage (guaranteed values) without previous operation Product Key +41 81 303 54 00 10 Load Limit Curve with Direct Current Tests, Regulations, Standards ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland 5,0 Maximal contact load at AC 1 with 230 V: 2 contacts with 8A each 3 contacts with 6A each 4 contacts with 4,5A each 2,5 SIF 4 2 2 24VDC AC 15: 230V 100 **without spark suppression Approvals DC 1: 24V 1000 Maximal switching characteristics (DIN EN 60947-5-1) AC 1: 250 V / 8 A AC 15: 230 V / 5 A DC 1: 24 V / 8 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Current (A) 3,1 10,9 2,9 4,1 3,1 34 53 Insulation Data 53,6 47,4 3,1 54 Contact Lifetime for NO Contacts Operations x 1000 Relay Key Data Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. (c) Copyright 04/2018 17 SGR 282 ZK Series Circuit Diagram (relay top view) -- PCB relay with forcibly guided contacts -- Protective separation between coil and contacts (air and creepage distance >14 mm); protective separation between left and right contact side (air and creepage distance >5,5 mm) -- IEC 61 810-3 type B -- 2 changeover contacts with notched crown -- Nominal coil power 0,7 W -- Holding coil power 0,21 W SGR282ZK A2 0,3 15 2,6 7,5 1 [mm] O1,3 2,5/2,54 Contact Data Contact material AgCuNi + 0,2 m Au Type of contact notched crown contact Rated switching capacity 250 VAC 8 A AC1 2 000 VA Electr. Life AC1(360 S / h) approx. 100 000 Inrush current max. 15 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 4 mA to 8 A Switching capacity range* 50 mW to 2000 W(VA) Contact resistance (as delivered) 100 m / 28 V / 100 mA *Guided values 0,5 0,6 1,2 1,8 2,4 4,8 6,0 11,0 140,0 116,0 58,5 38,9 29,1 14,5 11,6 6,3 Resistance in Ohm at 20 C 3,75 4,50 9,00 13,50 18,00 36,00 45,00 82,50 Nominal current in mA Min. pick-up voltage at 20 C 5 6 12 18 24 48 60 110 Drop-out voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 35,7 51,4 205,0 462,0 822,0 3 290,0 5 140,0 17 280,0 10% 10% 10% 10% 10% 10% 13% 15% 1000 -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >5,5 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >14 mm -- Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 550 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Additional Data Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 12 ms Drop-out time** (NC closed) typically 5 ms Bounce time of NO contact typically 4 ms Bounce time of NC contact typically 8 ms Shock resistance 16 ms NO > 10g NC > 2,5g Vibration resistance NO > 10g (10-55 Hz) NC > 1,5g Short-circuit resistance NO 1 000 A SCPD 10 A gG / gL (pre-fuse) NC 1 000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 50 K / W Temperature limit for coil 120C Weight approx. 20 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression Approvals UL File E188 953 Sec. 1 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V1 Standards IEC 61 810-1, IEC 61810-3 Options, Accessories AC 1: 400V DC 13: 24V 5,0 Maximal contact load at AC 1 with 230 V: 2 contacts with 8 A each Load Limit Curve with Direct Current 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 150 Voltage (VDC) ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 200 250 1)Inductive load L/R 40 ms 2)Resistive load Excitation Voltage Range 3,0 2,5 2,0 1 1,5 1,0 2 0 20 40 60 Ambient Temperature C 80 100 1)Max. excitation voltage with contact load: 4 A 2)Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. Product Key 18 10 Maximal switching capacity (DIN EN 60947-5-1, Tab. C2) AC 15: 230 V / 5 A DC 13: 24 V / 6 A UL 508: C300 Print socket, DIN-rail socket Wiring modules SGR282ZK24VDC DC 1: 24V 10 0,1 0,5 1,0 Switching Current (A) 0,5 UB UN 0 Tests, Regulations, Standards AC 1:230V AC 15: 230V 100 A1 Insulation Data 25,6 5 5 Operations x 1000 22 12 12,7 3,7 2,6 10000 24 14 21 11 Dimensions 30,2 Contact Lifetime for NO Contacts Current (A) Relay Key Data Coil voltage Type designation (c) Copyright 04/2018 SGR 282 ZK Series Variants 1 NO / 1 NC Circuit Diagram (relay top view) 12,7 14 21 11 24 21 11 A2 0,3 25,6 15 10000 1000 12 SGR282ZK A1 A2 2,6 7,5 1 Var1 O1,3 2,5/2,54 Var2 [mm] -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >5,5 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >14 mm -- Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 550 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Additional Data Contact Data Contact material AgCuNi + 0,2 m Au Type of contact notched crown contact Rated switching capacity 250 VAC 8 A AC1 2 000 VA Electr. Life AC1(360 S / h) approx. 100 000 Inrush current max. 15 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 4 mA to 8 A Switching capacity range* 50 mW to 2000 W(VA) Contact resistance (as delivered) 100 m / 28 V / 100 mA *Guided values 0,5 0,6 1,2 1,8 2,4 4,8 6,0 11,0 140,0 116,0 58,5 38,9 29,1 14,5 11,6 6,3 Resistance in Ohm at 20 C 3,75 4,50 9,00 13,50 18,00 36,00 45,00 82,50 Nominal current in mA Min. pick-up voltage at 20 C 5 6 12 18 24 48 60 110 Drop-out voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 35,7 51,4 205,0 462,0 822,0 3 290,0 5 140,0 17 280,0 10% 10% 10% 10% 10% 10% 13% 15% Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (NO closed) typically 12 ms Drop-out time (NC closed) typically 5 ms Bounce time of NO contact typically 4 ms Bounce time of NC contact typically 8 ms Shock resistance 16 ms NO > 10g NC > 2,5g Vibration resistance NO > 10g (10-55 Hz) NC > 1,5g Short-circuit resistance NO 1 000 A SCPD 10 A gG / gL (pre-fuse) NC 1 000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 50 K / W Temperature limit for coil 120C Weight approx. 20 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression Tests, Regulations, Standards Approvals UL File E188 953 Sec. 1 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V1 Standards IEC 61 810-1, IEC 61810-3 AC 1:230V AC 15: 230V DC 1: 24V AC 1: 400V 100 DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) A1 Insulation Data 3,7 5 5 VAR2 SGR282ZK 30,2 2,6 VAR1 22 Dimensions Contact Lifetime for NO Contact Operations x 1000 -- PCB relay with forcibly guided contacts -- Protective separation between coil and contacts (air and creepage distance >14 mm); protective separation between left and right contact side (air and creepage distance >5,5 mm) -- IEC 61 810-3 type A -- 1 NO / 1 NC witch notched crown -- Nominal coil power 0,7 W -- Holding coil power 0,21 W 5,0 10 Maximal switching capacity (DIN EN 60947-5-1, Tab. C2) AC 15: 230 V / 5 A DC 13: 24 V / 6 A UL 508: C300 Load Limit Curve with Direct Current 8 6 4 3 2 Current (A) Relay Key Data 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 150 Voltage (VDC) 200 250 1)Inductive load L/R 40 ms 2)Resistive load Excitation Voltage Range 3,0 2,5 2,0 1 1,5 1,0 0,5 UB UN 0 2 0 20 40 60 Ambient Temperature C 80 100 1)Max. excitation voltage with contact load: 4 A 2)Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. Options, Accessories Print socket, DIN-rail socket Wiring modules Product Key SGR282ZKVAR1 24VDC ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 Coil voltage Contact variant Type designation (c) Copyright 04/2018 19 SIM 2 Series Circuit Diagram (relay top view) -- PCB relay with forcibly guided contacts -- Protective separation between coil and contacts (air and creepage distance >14 mm); protective separation between left and right contact side (air and creepage distance >5,5 mm) -- IEC 61 810-3 type A -- Contact mounting: SIM112 1 NO / 1 NC -- Small external dimensions -- Nominal coil power 0,5 W -- Holding coil power 0,15 W 11 24 SIM112 A2 12,5 3,7 0,5 2,5 7,5 1 2,5 2,5 7,5 2,5 O 1,3 [mm] 2,8 15,9 5 Additional Data 3,7 Contact Data Contact material AgSnO2 + 0,2 m Au Type of contact crown contact Rated switching capacity 250 VAC 8 A AC1 2 000 VA Electr. Life AC1(360 S / h) approx. 100 000 Inrush current max. 20 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 8 A Switching capacity range* 60 mW to 2000 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values 0,5 0,6 1,2 2,1 2,4 4,8 6,0 11,0 111,0 85,7 44,4 23,8 21,8 10,9 8,7 5,5 Resistance in Ohm at 20 C Nominal current in mA Min. pick-up voltage at 20 C 3,5 4,2 8,4 14,7 16,8 33,6 42,0 77,0 Drop-out voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 5 6 12 21 24 48 60 110 -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >5,5 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >14 mm -- Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M 45 70 270 880 1100 4 400 6 850 20 000 10% 10% 10% 10% 10% 13% 15% 15% Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (NO closed) typically 10 ms Drop-out time (NC closed) typically 3 ms Bounce time of NO contact typically 6 ms Bounce time of NC contact typically 12 ms Shock resistance 16 ms NO > 10g NC > 2,5g Vibration resistance NO > 10g (10-200 Hz) NC > 1g Resistance to short circuiting contacts 1 000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 55 K / W Temperature limit for coil 120C Weight approx. 20 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression Approvals UL File E188 953 Sec. 3 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 Options, Accessories AC 1:230V DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 10 0,1 0 2 50 100 150 200 250 0 20 40 60 Ambient Temperature C 80 100 Voltage (VDC) 1)Inductive load L/R 40 ms 2)Resistive load Excitation Voltage Range 3,0 2,5 1 2,0 1,5 1,0 2 1)Max. excitation voltage with contact load: 6 A 2)Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. Product Key +41 81 303 54 00 5,0 Load Limit Curve with Direct Current none available ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland DC 1: 24V AC 15: 230V 100 0,5 UB UN 0 Tests, Regulations, Standards SIM 1 1 2 24VDC 20 1000 Maximal switching capacity (DIN EN 60947-5-1, Tab. C2) AC 1: 250 V / 8 A AC 15: 230 V / 3 A DC 1: 24 V / 8 A DC 13: 24 V / 6 A / 0,1 Hz UL 508: C150 / R300 Current (A) 0,3 0,4 15,9 5 A1 Insulation Data 26,2 2,9 2,8 10000 12 23 Dimensions 27,4 Contact Lifetime for NO Contact Operations x 1000 Relay Key Data Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 SIM 3 Series Circuit Diagram (relay top view) 12,5 2,9 26,2 36,1 2,5 7,5 2,5 2,5 7,5 2,5 2,8 2,8 0,3 0,4 15,9 5 5 5 2,4 O 1,3 0,5 2,5 1 2,5 7,5 Standard 15,9 5 5 5 2,4 O 1,3 KV2 15,9 5 5 5 [mm] 2,4 Contact Data Contact material AgSnO2 + 0,2 m Au Type of contact crown contact Rated switching capacity 250 VAC 8 A AC1 2 000 VA Electr. Life AC1(360 S / h) approx. 100 000 Inrush current max. 20 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 8 A Switching capacity range* 60 mW to 2000 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current (other voltages on request) 34 44 44 12 12 23 11 11 24 SIM212 A2 SIM212 A1 A2 Drop-out voltage at 20 C Nominal current in mA 0,5 0,6 1,2 2,1 2,4 151,0 125,0 63,1 35,5 30,0 33 48 190 590 800 10% 10% 10% 10% 10% 48 60 110 36,00 45,00 82,50 4,8 6,0 11,0 15,4 12,5 6,8 3 100 4 800 16 000 10% 13% 15% Resistance in Ohm at 20 C Min. pick-up voltage at 20 C 3,75 4,50 9,00 15,75 18,00 10000 1000 -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2 500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >5,5 mm -- Test voltage 4 000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >14 mm -- Test voltage 5 000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Additional Data Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 10 ms Drop-out time (NC closed) typically 4 ms Bounce time of NO contact typically 6 ms Bounce time of NC contact typically 12 ms Shock resistance 16 ms NO > 10g NC > 2,5g Vibration resistance NO > 10g (10-200 Hz) NC > 1g Resistance to short circuiting contacts 1 000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 50 K / W Temperature limit for coil 120C Weight approx. 25 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s Approvals AC 15: 230V DC 13: 24V 5,0 Options, Accessories 10 Maximal switching capacity (DIN EN 60947-5-1, Tab. C2) AC 1: 250 V / 8 A AC 15: 230 V / 3 A DC 1: 24 V / 8 A DC 13: 24 V / 6 A / 0,1 Hz UL 508: C150 / R300 Maximal contact load at AC 1 with 230 V: 2 contacts with 8 A each Load Limit Curve with Direct Current 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 150 200 250 60 80 100 1)Inductive load L/R 40 ms 2)Resistive load Excitation Voltage Range 3.0 2.5 1 2.0 1.5 1.0 2 0 20 40 Ambient Temperature C UL File E188 953 Sec. 3 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 DC 1: 24V 10 0,1 0,5 1,0 Switching Current (A) 0.5 UB UN 0 Tests, Regulations, Standards AC 1:230V 100 A1 **without spark suppression 5 6 12 21 24 Nominal voltage VDC Variant 2: KV2 43 Insulation Data Dimensions 2,8 Variant 1: Standard 33 43 Contact Lifetime Operations x 1000 -- PCB relay with forcibly guided contacts -- Protective separation between coil and contacts (air and creepage distance >14 mm); protective separation between left and right contact side (air and creepage distance >5,5 mm) -- IEC 61 810-3 type A -- Contact mounting: SIM212 2 NO / 1 NC -- Small external dimensions -- Nominal coil power 0,75 W -- Holding coil power 0,21 W -- Coils for railway applications according to EN 50 155 on request Current (A) Relay Key Data 1)Max. excitation voltage with contact load: 6 A 2)Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. Print socket, DIN-rail socket Product Key SIM 2 1 2 24VDC KV2 ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 Contact variant Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 21 SIM 4 Series Circuit Diagram (relay top view) -- PCB relay with forcibly guided contacts -- Protective separation between coil and contacts (air and creepage distance >14 mm); protective separation between left and right contact side (air and creepage distance >5,5 mm) -- IEC 61 810-3 type A -- Contact mounting: SIM312 3 NO / 1 NC SIM222 2 NO / 2 NC -- Small external dimensions -- Nominal coil power 1 W -- Holding coil power 0,29 W 34 44 12 23 12 22 11 24 11 21 SIM312 SIM222 0,5 2,5 2,4 O 1,3 7,5 15,9 5 5 5 1 2,5 2,4 Contact Data Contact material AgSnO2 + 0,2 m Au Type of contact crown contact Rated switching capacity 250 VAC 8 A AC1 2 000 VA Electr. Life AC1(360 S / h) approx. 100 000 Inrush current max. 20 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 8 A Switching capacity range* 60 mW to 2000 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values 0,5 0,6 1,2 2,1 2,4 4,8 6,0 11,0 181,8 166,0 85,7 46,6 40,0 20,8 16,6 9,6 Resistance in Ohm at 20 C 3,75 4,50 9,00 15,75 18,00 36,00 45,00 82,50 Nominal current in mA Min. pick-up voltage at 20 C 5 6 12 21 24 48 60 110 Drop-out voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 27,5 36,0 140,0 450,0 600,0 2 300,0 3 600,0 12 000,0 10% 10% 10% 10% 10% 10% 13% 15% A1 A2 10000 A1 -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >5,5 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >14 mm -- Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Additional Data Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 8 ms Drop-out time** (NC closed) typically 4 ms Bounce time of NO contact typically 6 ms Bounce time of NC contact typically 12 ms Shock resistance 16 ms NO > 10g NC > 2,5g Vibration resistance NO > 10g (10-200 Hz) NC > 1g Resistance to short circuiting contacts 1 000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 50 K / W Temperature limit for coil 120C Weight approx. 25 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression 1000 100 Approvals UL File E188 953 Sec. 3 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 AC 15: 230V DC 13: 24V Load Limit Curve with Direct Current 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 150 +41 81 303 54 00 200 250 80 100 1)Inductive load L/R 40 ms 2)Resistive load Excitation Voltage Range 3,0 2,5 2,0 1,5 1,0 1 2 0 20 40 60 Ambient Temperature C 1)Max. excitation voltage with contact load: 6 A 2)Min. excitation voltage (guaranteed values) without previous operation Product Key ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland 10 Maximal contact load at AC 1 with 230 V: 2 contacts with 8 A each 3 contacts with 6 A each Print socket, DIN-rail socket 22 5,0 Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. Options, Accessories SIM 3 1 2 24VDC DC 1: 24V 10 0,1 0,5 1,0 Switching Current (A) 0,5 UB UN 0 Tests, Regulations, Standards AC 1:230V Maximal switching capacity (DIN EN 60947-5-1, Tab. C2) AC 1: 250 V / 8 A AC 15: 230 V / 3 A DC 1: 24 V / 8 A DC 13: 24 V / 6 A / 0,1 Hz UL 508: C150 / R300 Current (A) 2,9 2,5 7,5 2,5 0,3 0,4 15,9 5 5 5 [mm] 2,8 33 43 34 44 Insulation Data 12,5 26,2 36,1 2,8 33 43 A2 Dimensions Contact Lifetime NO Contacts Operations x 1000 Relay Key Data Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 SLR 4 Series Circuit Diagram (relay top view) -- PCB relay with forcibly guided contacts -- Protective separation between the coil/control and output contacts (>8 mm) as well as output contacts against each other (>10 mm) -- IEC 61 810-3 type A -- Contact mounting: SLR312 3 NO / 1 NC SLR222 2 NO / 2 NC -- Small external dimensions -- Nominal coil power 0,6 W -- Holding coil power 0,18 W -- Coils for railway applications according to EN 50 155 on request Dimensions 4 1 13,7 11,3 1,4 16,7 [mm] 16,7 4 12,7 5,4 25 O 1,3 20,5 43 44 33 34 42 41 12 11 23 24 12 11 23 24 SLR312 A2 SLR222 A1 A2 A1 10000 6,4 10,7 6,4 -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >10 mm -- Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Contact Data Additional Data Contact material AgSnO2 + 0,2 m Au Type of contact crown contact Rated switching capacity 250 VAC 10 A AC1 2 500 VA Electr. Life AC1(360 S / h) approx. 100 000 Inrush current max. 25 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 10 A Switching capacity range* 60 mW to 2500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 15 ms Drop-out time** (NC closed) typically 4 ms Bounce time of NO contact typically 6 ms Bounce time of NC contact typically 12 ms Shock resistance 16 ms NO > 10g NC > 6g Vibration resistance NO > 5g (10-200 Hz) NC > 1,5 Resistance to short circuiting contacts 1 000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 55 K / W Temperature limit for coil 120C Weight approx. 30 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s *Guided values 0,5 0,6 1,2 1,8 2,4 4,8 6,0 11,0 121,0 100,0 50,0 33,3 25,2 12,6 10,0 5,5 Resistance in Ohm at 20 C 3,5 4,2 8,4 12,6 16,8 33,6 42,0 77,0 Nominal current in mA Min. pick-up voltage at 20 C 5 6 12 18 24 48 60 110 Drop-out voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 41 60 240 540 950 3 800 6 000 20 000 10% 10% 10% 10% 10% 10% 13% 15% **without spark suppression Approvals UL File E188 953 Sec. 3 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 Options, Accessories DC 1: 24V AC 15: 230V 100 DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) 5,0 10 Maximal contact load at AC 1 with 230 V: 2 contacts with 10 A each 3 contacts with 8,4 A each Load Limit Curve with Direct Current 10 8 6 4 3 2 1 0,8 0,6 0,4 0,3 0,2 1 2 0,1 50 100 0 Voltage (VDC) 1)Inductive load L/R 40 ms 2)Resistive load 150 200 250 Excitation Voltage Range 3,0 2,5 2,0 1 1,5 1,0 0,5 UB UN 0 Tests, Regulations, Standards AC 1:230V 1000 Maximal switching capacity (DIN EN 60947-5-1, Tab. C2) AC 15: 230 V / 5 A DC 13: 24 V / 7,5 A / 0,1 Hz UL 508: C600 / R300 Current (A) 3 3 0,4 0,6 20,5 6,4 10,7 6,46,4 0,3 2,9 16,5 33,4 component side 2,9 33 34 Insulation Data 53,3 2,9 Contact Lifetime NO Contacts Operations x 1000 Relay Key Data 2 0 20 40 60 Ambient Temperature C 80 100 1)Max. excitation voltage with contact load: 6 A 2)Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. none available Product Key SLR 3 1 2 24VDC ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 23 SIR 4 Series Circuit Diagram (relay top view) -- PCB relay with forcibly guided contacts -- Protective separation between the coil/control and output contacts (>10 mm) as well as output contacts against each other (>8 mm) -- IEC 61 810-3 type A -- Contact mounting: SIR312 3 NO / 1 NC SIR222 2 NO / 2 NC -- Small external dimensions -- Nominal coil power 0,6 W -- Holding coil power 0,18 W -- Coils for railway applications according to EN 50 155 on request Dimensions 0,7 30,7 2,9 33 43 34 44 12 23 12 22 11 24 11 21 SIR312 SIR222 A2 A1 A2 10000 A1 0,4 21 3 10 3 5 10,5 5 3 3 1 10 21 5 10,5 5 3 [mm] 3 -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >10 mm -- Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Contact Data Additional Data Contact material AgSnO2 + 0,2 m Au Type of contact crown contact Rated switching capacity 250 VAC 10 A AC1 2 500 VA Electr. Life AC1(360 S / h) approx. 100 000 Inrush current max. 25 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 10 A Switching capacity range* 60 mW to 2500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 15 ms Drop-out time** (NC closed) typically 4 ms Bounce time of NO contact typically 6 ms Bounce time of NC contact typically 12 ms Shock resistance 16 ms NO > 10g NC > 6g Vibration resistance NO > 5g (10-200 Hz) NC > 1,5 Resistance to short circuiting contacts 1 000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 55 K / W Temperature limit for coil 120C Weight approx. 30 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s *Guided values 0,5 0,6 1,2 1,8 2,4 4,8 6,0 11,0 121,0 100,0 50,0 33,3 25,2 12,6 10,0 5,5 Resistance in Ohm at 20 C 3,5 4,2 8,4 12,6 16,8 33,6 42,0 77,0 Nominal current in mA Min. pick-up voltage at 20 C 5 6 12 18 24 48 60 110 Drop-out voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 41 60 240 540 950 3 800 6 000 20 000 10% 10% 10% 10% 10% 10% 13% 15% **without spark suppression Approvals UL File E188 953 Sec. 3 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 Options, Accessories DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) 5,0 Load Limit Curve with Direct Current 10 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 150 200 60 80 ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 250 1)Inductive load L/R 40 ms 2)Resistive load Excitation Voltage Range 3,0 2,5 2,0 1 1,5 1,0 2 0 20 40 100 Ambient Temperature C 1)Max. excitation voltage with contact load: 6 A 2)Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. Product Key 24 10 Maximal contact load at AC 1 with 230 V: 2 contacts with 10 A each 3 contacts with 8,4 A each PCB socket SIR 3 1 2 24VDC DC 1: 24V AC 15: 230V 100 0,5 UB UN 0 Tests, Regulations, Standards AC 1:230V 1000 Maximal switching capacity (DIN EN 60947-5-1, Tab. C2) AC 15: 230 V / 5 A DC 13: 24 V / 7,5 A / 0,1 Hz UL 508: C600 / R300 Current (A) 16 O 1,3 1,9 33 43 34 44 Insulation Data 46,4 1,9 Contact Lifetime NO Contacts Operations x 1000 Relay Key Data Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 SIR 4 sensitive Series Circuit Diagram (relay top view) -- Printrelais mit zwangsgefuhrten Kontakten -- Sichere Trennung zwischen Spule/Steuerkontakten und Ausgangskontakten (>10 mm), sowie Ausgangskontakte zueinander (>8 mm) -- IEC 61 810-3 Anwendungstyp A -- Kontaktbestuckung: SIR312 3 AK / 1 RK SIR222 2 AK / 2 RK -- Kleine Aussenabmessungen -- Spulennennleistung 0,36 W -- Halteleistung 0,12 W -- Spulen fur Bahnanwendungen nach EN 50 155 auf Anfrage Abmessungen 0,7 2,9 1,9 3 3 1 10 5 10,5 5 3 [mm] O 1,3 21 12 23 12 22 11 24 11 21 SIR312SEN SIR222SEN A2 A1 A2 10000 AC 1:230V 1000 A1 3 -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >10 mm -- Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Kontaktdaten Additional Data KontaktmaterialAgSnO2 + 0,2 m Au KontaktartKronenkontakt Nennschaltleistung 250 VAC 10 A AC1 2 500 VA Elektr. Lebensdauer AC1(360 S / h) ca.100 000 Einschaltstrom max. 25 A fur 20 ms Schaltspannungsbereich 5 bis 250 VDC / VAC Schaltstrombereich* 10 mA bis 10 A Schaltleistungsbereich* 60 mW bis 2 500 W(VA) Kontaktubergangswid. (Neuzustand) 100 m / 6 V / 100 mA Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 18 ms Drop-out time** (NC closed) typically 5 ms Bounce time of NO contact typically 6 ms Bounce time of NC contact typically 12 ms Shock resistance 16 ms NO > 10g NC > 6g Vibration resistance NO > 5g (10-200 Hz) NC > 1,5 Resistance to short circuiting contacts 1 000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 55 K / W Temperature limit for coil 120C Weight approx. 30 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s *Richtwerte 5 6 9 12 18 24 48 60 3,75 4,50 6,75 9,00 13,50 18,00 36,00 45,00 0,5 0,6 0,9 1,2 1,8 2,4 3,6 4,5 72,0 60,0 40,0 30,0 20,0 15,0 7,5 6,0 Widerstand in Ohm bei 20 C Nennstrom in mA Ruckfallspannung bei 20 C Min. Ansprechspannung bei 20 C Nennspannung VDC Normspulen fur Gleichspannung (andere Spannungswerte auf Anfrage) 69,4 100,0 225,0 400,0 900,0 1 600,0 6 400,0 10 000,0 10% 10% 10% 10% 10% 10% 13% 15% **without spark suppression 100 DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) UL File E188 953 Sec. 3 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 Options, Accessories 10 Load Limit Curve with Direct Current 10 8 6 4 3 2 1 0,8 0,6 0,4 0,3 0,2 1 2 0,1 50 100 0 Voltage (VDC) 150 200 250 1)Inductive load L/R 40 ms 2)Resistive load Excitation Voltage Range 3,0 2,5 1 2,0 1,5 0,5 UB UN 0 Approvals 5,0 Maximal contact load at AC 1 with 230 V: 2 contacts with 10 A each 3 contacts with 8,4 A each 1,0 Tests, Regulations, Standards DC 1: 24V AC 15: 230V Maximal switching characteristics (DIN EN60947-5-1, Tab.C2) AC 15: 230 V / 5 A DC 13: 24 V / 7,5 A / 0,1 Hz UL 508: C600 / R300 Current (A) 16 30,7 5 10,5 5 3 10 3 0,4 21 33 43 34 44 Insulation Data 46,4 1,9 Contact Lifetime NO Contacts 33 43 34 44 Operations x 1000 Relais Eckdaten 2 0 20 40 60 Ambient Temperature C 80 100 1)Max. excitation voltage with contact load: 6 A (2 contacts) 2)Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. PCB socket Product Key SIR 3 1 2 24VDC SEN ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 sensitive coil Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 25 SIR 4 Power Series Circuit Diagram (relay top view) Dimensions 16 2,9 0,7 30,7 46,4 3 10 3 5 10,5 5 3 1 10 3 [mm] O 1,3 1,9 21 5 10,5 5 3 3 Output contacts 33 43 34 44 33 43 34 44 Control contacts 12 23 12 22 11 24 11 21 SIR312P SIR222P A2 A1 A2 Output contact data Contact material AgSnO2 Rated switching capacity 250 VAC (440 VAC) 12 A AC1 3 000 VA Electr. Life AC1(360 S / h) approx. 250 000 Inrush current max. 60 A for 20 ms Switching voltage range 5 to 250 VDC (480 VAC) Switching current range* 10 mA to 12 A Switching capacity range* 120 mW to 3000 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA Insulation Data -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >10 mm -- Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Mechanical endurance >10 x 10 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 15 ms Drop-out time** (NC closed) typically 4 ms Bounce time of NO contact typically 6 ms Bounce time of NC contact typically 12 ms Shock resistance 16 ms NO > 17g NC > 7g Vibration resistance NO > 10g (10-200 Hz) NC > 4,5g Resistance to short circuiting control contacts 1 000 A SCPD 6 A gG / gL (pre-fuse) Resistance to short circuiting output contacts 1 000 A SCPD 16 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 55 K / W Temperature limit for coil 120C Weight approx. 32 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression 26 0,5 1,2 1,8 2,0 2,4 4,8 6,0 11,0 151,0 63,1 41,6 37,7 31,5 15,7 12,5 6,8 Resistance in Ohm at 20 C Nominal current in mA Approvals Drop-out voltage at 20 C Standard coils for direct current (other voltages on request) Min. pick-up voltage at 20 C Tests, Regulations, Standards Nominal voltage VDC *Guided values 3,5 8,4 12,6 14,0 16,8 33,6 42,0 77,0 A1 DC 14: 24V 100 10 33 190 432 530 760 3 050 4 800 16 000 10% 10% 10% 10% 10% 10% 13% 15% 5 10 16 10000 1000 AC 1: 400V AC 1: 230V AC 3: 230V 100 10 AC 15: 230V 1 Switching Current (A) AC 3: 400V 5 10 16 Maximal contact load at AC 1 with 230 V: 2 contacts with 12 A each Load Limit Curve with Direct Current 12 8 6 4 3 2 1 0,8 0,6 0,4 0,3 0,2 2 1 0,1 0 50 100 Voltage (VDC) 150 200 250 60 80 100 1)Inductive load L/R 40 ms 2)Resistive load 2,5 2,0 Product Key 1 1,5 1,0 0,5 UB UN 0 PCB socket +41 81 303 54 00 Switching Current (A) 3,0 Options, Accessories ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland 1 Excitation Voltage Range UL File E188 953 Sec. 3 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 SIR 3 1 2 P 24VDC DC 13: 24V Contact life output contacts AC 6 Contact material AgSnO2 + 0,2 m Au Rated switching capacity 250 VAC 6 A AC1 1 500 VA Electr. Life AC1(360 S / h) approx. 100 000 Inrush current max. 15 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 5 mA to 6 A Switching capacity range* 60 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA DC 1: 24V 1000 Additional Data Control contact data 5 12 18 20 24 48 60 110 10000 Current (A) 0,4 1,9 21 Contact life output contacts DC Operations x 1000 -- PCB relay with forcibly guided contacts -- Protective separation between the coil/control and output contacts (>10 mm) as well as between output contacts (>8 mm) -- IEC 61 810-3 type A -- Contact mounting: SIR312P control contacts 1 NO / 1 NC output contacts 2 NO SIR222P control contacts 2 NC output contacts 2 NO -- Inrush current 60 A / continuous current 12 A -- Nominal coil power 0,75 W -- Holding coil power 0,23 W -- Coils for railway applications according to EN 50 155 on request Operations x 1000 Relay Key Data 2 0 20 40 Ambient Temperature C Coil voltage Power version Solder terminals Number of NC contacts Number of NO contacts Type designation 1)Max. excitation voltage with contact load: Control contacts 2 A, Output Control contacts 10 A 2)Min. excitation voltage (guaranteed values) without previous operation. (c) Copyright 04/2018 SIR 6 Series Circuit Diagram (relay top view) 2,9 0,7 30,7 16 5 10,5 5 7,5 5 3 3 10 1 3 O 1,3 3 10 3 1,9 [mm] 21 53 63 53 63 54 64 54 64 54 64 32 42 33 42 33 43 31 41 34 41 34 44 12 23 12 23 12 23 11 24 11 24 11 24 SIR332 SIR422 SIR512 A1 A2 A1 A2 10000 AC 1:230V A1 Insulation Data 58,9 0,4 21 53 63 A2 Dimensions 1,9 Contact Lifetime NO Contacts Operations x 1000 -- PCB relay with forcibly guided contacts -- Protective separation between the coil/control and output contacts (>10 mm) as well as between output contacts (>8 mm) -- IEC 61 810-3 type A -- Contact mounting: SIR332 3 NO / 3 NC SIR422 4 NO / 2 NC SIR515 5 NO / 1 NC -- Small external dimensions -- Nominal coil power 0,75 W -- Holding coil power 0,22 W -- Coils for railway applications according to EN 50 155 on request 5 10,5 5 7,5 5 3 -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >10 mm -- Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Contact Data Additional Data Contact material AgSnO2 + 0,2 m Au Type of contact crown contact Rated switching capacity 250 VAC 10 A AC1 2 500 VA Electr. Life AC1(360 S / h) approx. 100 000 Inrush current max. 25 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 10 A Switching capacity range* 60 mW to 2500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 15 ms Drop-out time** (NC closed) typically 4 ms Bounce time of NO contact typically 6 ms Bounce time of NC contact typically 12 ms Shock resistance 16 ms NO > 10g NC > 6g Vibration resistance NO > 5g (10-200 Hz) NC > 2g Resistance to short circuiting contacts 1 000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 55 K / W Temperature limit for coil 120C Weight approx. 35 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s *Guided values 0,5 0,6 1,2 1,8 2,4 4,8 6,0 11,0 151,0 125,0 63,1 41,6 31,5 15,7 12,5 6,8 Resistance in Ohm at 20 C 3,5 4,2 8,4 12,6 16,8 33,6 42,0 77,0 Nominal current in mA Min. pick-up voltage at 20 C 5 6 12 18 24 48 60 110 Drop-out voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 33 48 190 432 760 3 050 4 800 16 000 10% 10% 10% 10% 10% 10% 13% 15% **without spark suppression 1000 100 DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) Approvals UL File E188 953 Sec. 3 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 Options, Accessories 5,0 10 Maximal contact load at AC 1 with 230 V: 2 contacts with 10A each 3 contacts with 8,4A each 4 contacts with 7,3A each 5 contacts with 6A each Load Limit Curve with Direct Current 10 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 2 0,1 50 100 0 Voltage (VDC) 150 200 60 80 250 1)Inductive load L/R 40 ms 2)Resistive load Excitation Voltage Range 3,0 2,5 2,0 1 1,5 1,0 0,5 UB UN 0 Tests, Regulations, Standards DC 1: 24V AC 15: 230V Maximal switching capacity (DIN EN 60947-5-1, Tab. C2): AC 15: 230 V / 5 A DC13: 24 V / 7,5 A / 0,1 Hz UL 508: C600 / R300 Current (A) Relay Key Data 2 0 20 40 100 Ambient Temperature C 1)Max. excitation voltage with contact load: 6 A 2)Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. none available Product Key SIR 4 2 2 24VDC ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 27 SIR 6 sensitive Series Circuit Diagram (relay top view) 16 2,9 0,7 30,7 58,9 0,4 21 5 10,5 5 7,5 5 3 3 10 1 3 3 10 3 O 1,3 [mm] 1,9 53 63 53 63 54 64 54 64 54 64 32 42 33 42 33 43 31 41 34 41 34 44 12 23 12 23 12 23 11 24 11 24 11 24 SIR332SEN SIR422SEN SIR512SEN A2 A1 A2 A1 A2 10000 AC 1:230V A1 Insulation Data Dimensions 1,9 Contact Lifetime NO Contacts 53 63 21 5 10,5 5 7,5 5 3 -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >10 mm -- Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Additional Data Contact Data Contact material AgSnO2 + 0,2 m Au Type of contact crown contact Rated switching capacity 250 VAC 10 A AC1 2 500 VA Electr. Life AC1(360 S / h) approx. 100 000 Inrush current max. 25 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 10 A Switching capacity range* 60 mW to 2500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA 5 6 9 12 18 24 48 60 3,75 4,50 6,75 9,00 13,50 18,00 36,00 45,00 0,5 0,6 0,9 1,2 1,8 2,4 3,6 4,5 100,0 83,3 56,2 41,6 27,7 20,8 10,4 8,3 Resistance in Ohm at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 50 72 160 288 648 1150 4 600 7 200 10% 10% 10% 10% 10% 10% 13% 15% Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 18 ms Drop-out time** (NC closed) typically 5 ms Bounce time of NO contact typically 6 ms Bounce time of NC contact typically 12 ms Shock resistance 16 ms NO > 10g NC > 6g Vibration resistance NO > 5g (10-200 Hz) NC > 2g Resistance to short circuiting contacts 1 000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 55 K / W Temperature limit for coil 120C Weight approx. 35 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression Operations x 1000 -- PCB relay with forcibly guided contacts -- Protective separation between the coil/control and output contacts (>10 mm) as well as between output contacts (>8 mm) -- IEC 61 810-3 type A -- Contact mounting: SIR332 3 NO / 3 NC SIR422 4 NO / 2 NC SIR515 5 NO / 1 NC -- Small external dimensions -- Nominal coil power 0,5 W -- Holding coil power 0,18 W -- Coils for railway applications according to EN 50 155 on request 1000 100 DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) Approvals 5,0 Load Limit Curve with Direct Current 10 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 1)Inductive load L/R 40 ms 2)Resistive load 150 200 60 80 250 Excitation Voltage Range 3,0 2,5 1 2,0 1,5 2 1,0 0 20 40 100 UL File E188 953 Sec. 3 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 Ambient Temperature C 1)Max. excitation voltage with contact load: 6 A (2 contacts) 2)Min. excitation voltage (guaranteed values) without previous operation Options, Accessories Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. none available Product Key SIR 4 2 2 24VDC SEN 28 10 Maximal contact load at AC 1 with 230 V: 2 contacts with 10A each 3 contacts with 8,4A each 4 contacts with 7,3A each 5 contacts with 6A each 0,5 UB UN 0 Tests, Regulations, Standards DC 1: 24V AC 15: 230V Maximal switching capacity (DIN EN 60947-5-1, Tab. C2): AC 15: 230 V / 5 A DC13: 24 V / 7,5 A / 0,1 Hz UL 508: C600 / R300 Current (A) Relay Key Data ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 sensitive coil Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 SIR 8 Series Circuit Diagram (relay top view) 73 74 52 51 32 31 12 11 A2 3,75 12,5 3,75 2 0,3 5 7,5 57,5 5 7,5 5 3,1 3,75 12,5 1 3,75 O 1,3 [mm] 37,9 5 7,5 5 7,5 5 7,5 5 3,1 Contact Data Contact material AgSnO2 + 0,2 m Au Type of contact crown contact Rated switching capacity 250 VAC 10 A AC1 2 500 VA Electr. Life AC1 (360 S / h) approx. 100 000 Inrush current max. 25 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 10 A Switching capacity range* 60 mW to 2500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values 4,2 8,4 12,6 16,8 33,6 42,0 77,0 154,0 0,6 1,2 1,8 2,4 4,8 6,0 11,0 22,0 218,0 109,0 72,0 54,5 27,2 11,8 6,8 5,9 Resistance in Ohm at 20 C Nominal current in mA Drop-out voltage at 20 C Min. pick-up voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 6 12 18 24 48 60 110 220 27,5 110,0 250,0 440,0 1 760,0 2 750,0 9 250,0 37 000,0 SIR532 A1 73 74 52 51 32 31 12 11 A2 83 84 62 61 42 41 23 24 SIR352 A2 83 84 63 64 42 41 22 21 SIR442 83 73 84 74 63 53 64 54 43 33 44 34 22 13 21 14 73 74 53 54 32 34 12 11 A2 A1 73 74 53 54 32 31 12 11 SIR622 A1 A2 A1 83 84 63 64 43 44 22 21 SIR712 A1 Insulation Data 32 2,9 0,5 0,4 37,9 A1 83 84 63 64 42 41 22 21 A2 20 85,5 SIR262 73 74 53 54 33 34 12 11 Dimensions 2 83 84 62 61 42 41 22 21 Contact Lifetime NO Contacts 10% 10% 10% 10% 10% 10% 13% 15% -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4,000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >10 mm -- Test voltage 5,000 V / 50 Hz / 1 min Test voltage contact open 1,500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Additional Data Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 15 ms Drop-out time** (NC closed) typically 4 ms Bounce time of NO contact typically 6 ms Bounce time of NC contact typically 12 ms Shock resistance 16 ms NO > 10g NC > 6g Vibration resistance NO > 8g (10-200 Hz) NC > 2.5g Resistance to short circuiting contacts 1,000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 40 K / W Temperature limit for coil 125C Weight approx. 60 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression 10000 Operations x 1000 -- PCB relay with forcibly guided contacts -- Protective separation between the coil and all contacts (>10 mm) as well as contacts one behind the other (>8 mm) and the left-hand side contacts to the right-hand side contacts (>10 mm) -- IEC 61 810-3 type A -- Contact mounting: SIR262 2 NO / 6 NC SIR352 3 NO / 5 NC SIR442 4 NO / 4 NC SIR532 5 NO / 3 NC SIR622 6 NO / 2 NC SIR712 7 NO / 1 NC -- Small external dimensions -- Nominal coil power 1,3 W -- Holding coil power 0,39 W -- Coils for railway applications according to EN 50 155 on request AC 1:230V 1000 100 DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) Approvals UL File E188953 Sec. 3 Insulation class IEC 60664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61810-1, IEC 61810-3 Options, Accessories 5,0 10 Maximal contact load at AC 1 with 230 V: 2 contacts with 10A each 3 contacts with 8,4A each 4 contacts with 7,3A each 5 contacts with 6,5A each 6 contacts with 6 A each Load Limit Curve with Direct Current 10 8 6 4 3 2 1 0,8 0,6 0,4 0,3 0,2 1 2 0,1 50 100 0 Voltage (VDC) 150 200 250 1)Inductive load L/R 40 ms 2)Resistive load Excitation Voltage Range 3,0 2,5 2,0 1,5 1 1,0 2 0,5 UB UN 0 Tests, Regulations, Standards DC 1: 24V AC 15: 230V Maximal switching capacity (DIN EN 60947-5-1, Tab. C2): AC 15: 230 V / 5 A DC13: 24 V / 7,5 A / 0,1 Hz UL 508: C600 / R300 Current (A) Relay Key Data 0 20 40 60 Ambient Temperature C 80 100 1)Max. excitation voltage with contact load: 6 A 2)Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. none available Product Key SIR 3 5 2 24VDC ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 29 SIR 10 Series Dimensions A2 SIR282 93 94 73 74 53 54 32 31 12 11 A2 20 85,5 103 93 104 94 82 72 81 71 62 52 61 51 42 32 41 31 22 12 21 11 93 94 72 71 52 51 32 31 12 11 A1 103 104 83 84 62 61 42 41 23 24 SIR642 A1 A2 103 104 82 81 62 61 42 41 23 24 SIR372 A1 SIR462 103 93 104 94 83 73 84 74 63 53 64 54 42 33 41 34 23 12 24 11 93 94 73 74 53 54 32 31 12 11 A2 103 93 104 94 82 73 81 74 62 52 61 51 42 32 41 31 23 12 24 11 93 94 72 71 52 51 33 34 12 11 A2 SIR732 A1 A2 Contact Lifetime NO Contacts A1 A2 103 104 83 84 62 61 42 41 23 24 SIR552 103 93 104 94 83 73 84 74 63 53 64 54 42 33 41 34 23 12 24 11 SIR822 A1 A2 A1 103 104 83 84 63 64 43 44 23 24 SIR912 A1 2,9 0,3 32 Insulation Data 0,5 0,4 1 25,4 5 7,5 5 7,5 5 7,5 5 7,5 5 3,1 3,75 12,5 3,75 3,75 2 12,5 O 1,3 3,75 [mm] 2 25,4 5 7,5 5 7,5 5 7,5 5 7,5 5 3,1 -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Contact Data Additional Data Contact material AgSnO2 + 0,2 m Au Type of contact crown contact Rated switching capacity 250 VAC 10 A AC1 2 500 VA Electr. Life AC1(360 S / h) approx. 100 000 Inrush current max. 25 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 10 A Switching capacity range* 60 mW to 2500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 18 ms Drop-out time** (NC closed) typically 5 ms Bounce time of NO contact typically 8 ms Bounce time of NC contact typically 12 ms Shock resistance 16 ms NO > 10g NC > 6g Vibration resistance NO > 8g (10-200 Hz) NC > 2,5g Resistance to short circuiting contacts 1 000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 40 K / W Temperature limit for coil 125C Weight approx. 60 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s *Guided values 6 12 18 24 48 60 110 220 4,2 8,4 12,6 16,8 33,6 42,0 77,0 154,0 0,6 1,2 1,8 2,4 4,8 6,0 11,0 22,0 218,0 109,0 72,0 54,5 27,2 11,8 6,8 5,9 Resistance in Ohm at 20 C Nominal current in mA Drop-out voltage at 20 C Min. pick-up voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 27,5 110,0 250,0 440,0 1 760,0 2 750,0 9 250,0 37 000,0 10% 10% 10% 10% 10% 10% 13% 15% **without spark suppression Tests, Regulations, Standards Approvals UL File E188 953 Sec. 3 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 Options, Accessories 10000 AC 1: 230V Operations x 1000 Circuit Diagram (relay top view) -- PCB relay with forcibly guided contacts -- Protective separation between the coil/control and output contacts (>8 mm) as well as output contacts one behind the other (>8 mm) and the left-hand side contacts to the right-hand side contacts (>10 mm) -- IEC 61 810-3 type A -- Contact mounting: SIR282 2 NO / 8 NC SIR372 3 NO / 7 NC SIR462 4 NO / 6 NC SIR552 5 NO / 5 NC SIR642 6 NO / 4 NC SIR732 7 NO / 3 NC SIR822 8 NO / 2 NC SIR912 9 NO / 1 NC -- Nominal coil power 1,3 W -- Holding coil power 0,39 W -- Coils for railway applications according to EN 50 155 on request 1000 100 DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) 5,0 Maximal contact load at AC 1 with 230 V: 2 contacts with 10A each 3 contacts with 8,4A each 4 contacts with 7,3A each 5 contacts with 6,5A each 6 contacts with 6 A each 8 contacts with 5 A each 9 contacts with 4,2A each Load Limit Curve with Direct Current 10 8 6 4 3 2 1 0,8 0,6 0,4 0,3 0,2 1 2 0,1 50 100 0 Voltage (VDC) 150 ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 200 250 1)Inductive load L/R 40 ms 2)Resistive load Excitation Voltage Range 3,0 2,5 2,0 1,5 1 1,0 2 0,5 UB UN 0 0 20 40 60 Ambient Temperature C 80 100 1)Max. excitation voltage with contact load: 6 A 2)Min. excitation voltage (guaranteed values) without previous operation Product Key 30 10 Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. none available SIR 7 3 2 24VDC DC 1: 24V AC 15: 230V Maximal switching capacity (DIN EN 60947-5-1, Tab. C2): AC 15: 230 V / 5 A DC13: 24 V / 7,5 A / 0,1 Hz UL 508: C600 / R300 Current (A) Relay Key Data Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation (c) Copyright 04/2018 SIP 6 Series Circuit Diagram (relay top view) Dimensions 32 2,9 12,5 2,1 3,75 6,5 14 3,75 6,5 14 3,75 12,5 3,75 0,4 2,1 25,4 5 8,5 5 6,5 5 6,5 5 6,5 5 4,1 0,5 3 O 1,3 25,4 5 8,5 5 6,5 5 6,5 5 6,5 5 0,5 20 84,6 1 3 [mm] 4,1 Contact material AgSnO2 + 0,2 m Au Rated switching capacity 250 VAC 6 A AC1 1 500 VA Electr. Life AC1(360 S / h) approx. 100 000 Inrush current max. 15 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 5 mA to 6 A Switching capacity range* 60 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA Output contact data Contact material AgSnO2 Rated switching capacity 250 VAC (440 VAC) 16 A AC1 4 000 VA Electr. Life AC1(360 S / h) approx. 250 000 Inrush current max. 60 A for 20 ms Switching voltage range 5 to 250 VDC (480 VAC) Switching current range* 10 mA to 16 A Switching capacity range* 120 mW to 4000 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values 218,0 109,0 72,0 54,5 27,2 21,8 11,8 5,9 43 44 Output contacts 33 Control contacts 12 23 11 24 12 22 11 21 SIP 512 SIP 422 A2 33 34 A1 A2 27,5 110,0 248,0 440,0 1 760,0 2 750,0 9 250,0 37 000,0 10% 10% 10% 10% 10% 10% 13% 15% 10000 54 44 34 A1 Operations x 1000 53 54 Insulation Data -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >10 mm -- Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 18 ms Drop-out time** (NC closed) typically 5 ms Bounce time of NO contact typically 8 ms Bounce time of NC contact typically 12 ms Shock resistance 16 ms NO > 10g NC > 8g Vibration resistance 10-200 Hz NO > 10g 10-49 Hz NC > 5g 50-200 Hz NC > 3,5g Resistance to short circuiting control contacts 1 000 A SCPD 6 A gG / gL (pre-fuse) Resistance to short circuiting output contacts 1 000 A SCPD 16 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 40 K / W Temperature limit for coil 125C Weight approx. 60 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s Approvals UL File E188 953 Sec. 4 Insulation class IEC 60 664-1 250 VAC Fire protection requirements UL 94 / V0 Standards IEC 61 810-1, IEC 61810-3 Options, Accessories Product Key ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 DC 1: 24V DC 14: 24V 100 10 DC 13: 24V 1 5 Switching Current (A) 10 16 Contact life output contacts AC 10000 AC 3: 230V 1000 AC 1: 400V AC 1: 230V AC 3: 400V 100 AC 15: 230V 10 1 5 Switching Current (A) UL508: A600 / R150 Maximal contact load at AC 1 with 230 V: 2 contacts with 16 A each 3 contacts with 12 A each 4 contacts with 10A each 10 16 Load Limit Curve with Direct Current 16 8 4 2 1 0,8 0,4 1 2 0,2 0,1 0 50 100 150 Voltage (VDC) 1)Inductive load L/R 40 ms 2)Resistive load 200 250 Excitation Voltage Range 2,5 2,0 1,5 1 1,0 2 0,5 UB UN 0 none available SIP 4 2 2 24VDC 1000 3,0 Tests, Regulations, Standards Resistance in Ohm at 20 C Nominal current in mA Min. pick-up voltage at 20 C Nominal voltage VDC Drop-out voltage at 20 C 0,6 1,2 1,8 2,4 4,8 6,0 11,0 22,0 43 64 **without spark suppression Standard coils for direct current (other voltages on request) 4,2 8,4 12,6 16,8 33,6 42,0 77,0 154,0 53 63 64 Additional Data Control contact data 6 12 18 24 48 60 110 220 63 Contact life output contacts DC Operations x 1000 -- PCB relay with forcibly guided contacts -- Protective separation between the coil/control and output contacts (>8 mm) as well as output contacts one behind the other (>10 mm) -- IEC 61 810-3 type A -- Contact mounting: SIP512 control contacts 1 NO / 1 NC output contacts 4 NO SIP422 control contacts 2 NC output contacts 4 NO -- High switching capacity -- Nominal coil power 1,3 W -- Holding coil power 0,39 W -- Coils for railway applications according to EN 50 155 on request Current (A) Relay Key Data Coil voltage Solder terminals Number of NC contacts Number of NO contacts Type designation 0 20 40 60 80 100 Ambient Temperature C 1)Max. excitation voltage with contact load: Control contacts 4 A, Output Control contacts 12 A 2)Min. excitation voltage (guaranteed values) without previous operation (c) Copyright 04/2018 31 Relay Accessories for series SGR 282 ZK PCB socket SRP-SGR2 DIN rail socket SRD-SGR2 Modules for SRD-SGR2 Socket Data Socket Data Module SRD-SGR2-M01 -- With plastic retaining bracket -- Socket with print connections -- With plastic retaining bracket and marking tag (1 pc.) -- Screw terminals -- Assembly on DIN rail 35 mm or single-hole mounting with M3 screw -- For DIN rail socket SRD-SGR2 -- Free-wheeling diode 6 VDC to 230VDC (+ at terminal A1) A1 + A2 - Module SRD-SGR2-M02 -- For DIN rail socket SRD-SGR2 -- Free-wheeling diode with red LED, 6 VDC to 24 VDC (+ at terminal A1) Module SRD-SGR2-M03 -- For DIN rail socket SRD-SGR2 -- Free-wheeling diode with green LED, 6 VDC to 24 VDC (+ at terminal A1) A1 + Dimensions Dimensions 4,8 A2 - -- For DIN rail socket SRD-SGR2 -- Red LED with inverse-polarity protection, 6 VDC to 230VDC (+ at terminal A1) 24 15 68,6 42,5 4,8 12,7 10,8 Module SRD-SGR2-M05 6 31 O 1,5 -- For DIN rail socket SRD-SGR2 -- Green LED with inverse-polarity protection, 6 VDC to 230VDC (+ at terminal A1) 12 22 COIL NO 11 COM 24 14 [mm] 21 15,5 60 A2 A1 NC 3,2 Module SRD-SGR2-M04 3 9,0 [mm] A1 + 37,5 75 2,5/2,54 A2 - Technical Data Rated current Rated voltage Test voltage coil/contacts Insulation class IEC 60 664-1 Creepage resistance Weight Ambient temperature Packing unit Approvals UL File 32 Technical Data 2x8A 300 VAC 4 000 Vrms 250 VAC CTI 250 approx. 4 g -40C to +70C 100 pcs UL, cUL E113714 Rated current Rated voltage Test voltage coil/contacts Insulation class IEC 60 664-1 Creepage resistance Weight Ambient temperature Connection cross-sections for wire for wire end ferrules Maximum torque Packing unit Approvals UL File ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 2x8A 300 VAC 4 000 Vrms 250 VAC CTI 250 approx. 40 g -25C to +70C 2 x 2,5 mm2 2 x 1,5 mm2 0,8 Nm 20 pcs UL, cUL E113714 (c) Copyright 04/2018 Relay Accessories for Series SGR 282 ZK with protective separation DIN rail socket SRD-SGR2 KV2 DIN rail socket SRD-SGR2A KV2 Modules Socket Data Socket Data Module SRD-SGR2A M01 -- With plastic retaining bracket and marking tag (1 pc.) -- Screw terminals -- Assembly on DIN rail 35 mm or single-hole mounting with M3 screw -- With plastic retaining bracket and marking tag (1 pc.) -- Push-in contacts -- Assembly on DIN rail 35 mm or single-hole mounting with M3 screw -- For DIN rail socket SRD-SGR2A -- With free-wheeling diode D1 +A1 D --A2 Module SRD-SGR2A M03 -- For DIN rail socket SRD-SGR2A -- Free-wheeling diode with green LED D1+A1 LD D R Dimensions --A2 35,4 22,6 32,5 30,6 28,3 15,8 O3,2 = 34,7 O3,2 30,3 37,2 15,8 = 24,6 44 32 36 73,7 75,3 60,9 22,4 17,5 17,5 Dimensions 95,6 78,6 Technical Data Technical Data Rated current 2x8A Rated voltage 250 VAC Test voltage coil/contacts 5 000 Vrms Please also observe the test voltage of the relay! Insulation class IEC 60 664-1 250 VAC Creepage resistance CTI 250 Weight approx. 4 g Ambient temperature -40C to +70C Connection cross-sections for wire 1 x 6 mm2 or 2 x 2,5 mm2 for wire end ferrules 1 x 6 mm2 or 2 x 2,5 mm2 Maximum torque 0,5 Nm Packing unit 20 pcs Approvals UL, cUL Rated current 2x8A Rated voltage 250 VAC Test voltage coil/contacts 5 000 Vrms Please also observe the test voltage of the relay! Insulation class IEC 60 664-1 250 VAC Creepage resistance CTI 250 Weight approx. 40 g Ambient temperature -40C to +70C Connection cross-sections for wire 2x (0,2 x 1,5) mm2 for wire end ferrules 2x (0,2 x 1,5) mm2 Maximum torque 0,5 Nm Packing unit 20 pcs Approvals UL, cUL ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 (c) Copyright 04/2018 33 Relay Accessories for series SIM 3, SIM 4 and SIR 4 PCB socket SRP-SIR4 DIN rail socket SRD-SIM4 Socket Data Socket Data -- With plastic retaining bracket -- Socket with print connections -- With plastic retaining bracket -- Socket screw terminals -- Assembly on DIN rail 35 mm or with 2 x M3 screws -- PCB socket for SIR4 contacts -- With plastic retaining bracket -- Socket with print connections Dimensions Dimensions Dimensions 5 10,5 5 31 21 11,5 A2 A1 11 34 12 60 75,1 46,7 O 1,5 10 [mm] 24/21 44 23/22 43 33 [mm] 31 16 SA-SIM4 ELESTA 4,1 71 7,5 3,4 3,4 0,5 60 40,2 0,5 O1,5 5 5 5 15,9 44,7 Socket Data 19,4 PCB socket SRP-SIM4 [mm] 57 SRD-SIM4 (SIM312...) SRD-SIM4 (SIM222...) Technical Data Rated current Rated voltage Test voltage coil/contacts Insulation class IEC 60 664-1 Creepage resistance Weight Ambient temperature Packing unit Approvals UL File 34 43 44 43 44 33 23 11 34 24 12 33 21 11 34 22 12 A1 A2 A1 A2 Technical Data Technical Data 8A 250 VAC 4 000 Vrms 250 VAC CTI 250 approx. 11 g -25C to +70C 10 pcs UL, cUL E301947 Rated current Rated voltage Test voltage coil/contacts Insulation class IEC 60 664-1 Creepage resistance Weight Ambient temperature Connection cross-sections for wire for wire end ferrules Maximum torque Packing unit Approvals UL File ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland +41 81 303 54 00 8A 250 VAC 3 000 Vrms 250 VAC CTI 250 approx. 65 g -25C to +70C 2 x 2,5 mm2 2 x 1,5 mm2 0,8 Nm 10 pcs UL, cUL E238167 Rated current Rated voltage Test voltage coil/contacts Insulation class IEC 60 664-1 Creepage resistance Weight Ambient temperature Packing unit Approvals UL File (c) Copyright 04/2018 8A 250 VAC 4 000 Vrms 250 VAC CTI 250 approx. 15 g -25C to +70C 10 pcs UL, cUL E301947 Switzerland: ELESTA GmbH Heuteilstrasse 18 CH-7310 Bad Ragaz Switzerland Phone: +41 (0) 81 303 54 00 Email: admin@elesta-gmbh.com Internet: www.elesta-gmbh.com Germany: ELESTA GmbH Sales office Leipzig Unterer Haselberg 32 D-04683 Naunhof Germany Phone: +49 (0) 34293 47 38 18 Email: m.meyer@elesta-gmbh.com Internet: www.elesta-gmbh.com ELESTA GmbH Phone: +49 (0) 7144 160 21 34 Sales office Stuttgart Emal: y.kihodu@elesta-gmbh.com Bergstrasse 16 Internet: www.elesta-gmbh.com D-71711 Steinheim an der Murr Germany www.elesta-gmbh.com Your ELESTA Partner ELESTA GmbH 04_2018 Global: