Digital Storage Oscilloscopes TDS2000C Series Data Sheet Ease-of-Use Features 16 Automated Measurements, and FFT Analysis for Simplified Waveform Analysis Built-in Waveform Limit Testing Automated, Extended Data Logging Feature Autoset and Signal Auto-ranging Built-in Context-sensitive Help Probe Check Wizard Multiple-language User Interface 5.7 in. (144 mm) Active TFT Color Display Features & Benefits Key Performance Specifications 200 MHz, 100 MHz, 70 MHz, 50 MHz Bandwidth Models 2- and 4-channel Models Up to 2 GS/s Sample Rate on All Channels 2.5k point Record Length on All Channels Advanced Triggers including Pulse Width Trigger and Line-selectable Video Trigger Small Footprint and Lightweight - Only 4.9 in. (124 mm) Deep and 4.4 lb. (2 kg) Connectivity USB 2.0 Host Port on the Front Panel for Quick and Easy Data Storage, Printing, and Connecting a USB Keyboard USB 2.0 Device Port on Rear Panel for Easy Connection to a PC or Direct Printing to a PictBridge(R)-compatible Printer Includes National Instrument's LabVIEW SignalExpressTM TE Limited Edition and Tektronix OpenChoice(R) Software for Connecting Your Bench Lifetime Warranty*1 *1 Limitations apply. For terms and conditions, visit www.tektronix.com/lifetimewarranty. Data Sheet Quickly and easily capture waveforms with advanced triggering. See all the details other oscilloscopes might miss with Tektronix proprietary digital real-time sampling. Performance You Need at a Price You Can Afford The TDS2000C Digital Storage Oscilloscope Series provides you with affordable performance in a compact design. Packed with standard features - including USB connectivity, 16 automated measurements, limit testing, data logging, and context-sensitive help - the TDS2000C Series oscilloscopes help you get more done, in less time. Digital Precision for Accurate Measurements With up to 200 MHz bandwidth and 2 GS/s maximum sample rate, no other digital storage oscilloscope offers as much bandwidth and sample rate for the price. Tektronix proprietary sampling technology provides real-time sampling with a minimum of 10X oversampling on all channels, all the time to accurately capture your signals. Sampling performance is not reduced when using multiple channels. Critical Tools for Troubleshooting Your Device Advanced triggers - rising/falling edge, pulse width, and video - help you quickly isolate your signals of interest. Once you've captured a signal, advanced math capabilities and automated measurements can speed your analysis. Quickly perform an FFT or add, subtract, or multiply waveforms. Sixteen automated measurements quickly and reliably calculate important signal characteristics such as frequency or rise time, while the built-in Limit Test function enables you to easily identify problems in your signal. 2 www.tektronix.com Quickly perform an FFT with the advanced math functions. Designed to Make Your Work Easy The TDS2000C Series oscilloscopes are designed with the ease of use and familiar operation you have come to expect from Tektronix. Intuitive Operation The intuitive user interface with dedicated per-channel vertical controls, auto-setup, and auto-ranging makes these instruments easy to use, reducing learning time and increasing efficiency. Digital Storage Oscilloscopes -- TDS2000C Series The context-sensitive Help system provides important information specific to the task you are working on. Limit Test provides a quick pass/fail comparison of any triggered input signal to a user-defined template. Help When You Need It, Where You Need It The built-in Help menu provides you with important information on your oscilloscope's features and functions. Help is provided in the same languages as the user interface. Probe Check Wizard Check out your probe compensation before making measurements with just one button that starts a fast, easy procedure. Limit Test The oscilloscope can automatically monitor source signals and output Pass or Fail results by judging whether the input waveform is within predefined Data Logging enables automatic saving of triggered waveforms for up to 8 hours. Conveniently use your USB flash drive to store screenshots and waveform data. boundaries. Specific actions can be triggered on violation including stopping waveform acquisition, stopping Limit Test functions, saving the failed waveform data or screen image to a USB memory device, or any combination of the above. This is an ideal solution for manufacturing or service applications where you need to make decisions quickly. Flexible Data Transfer The USB host port on the front panel enables you to save your instrument settings, screenshots, and waveform data in a flash. The built-in data logging feature means you can set up your oscilloscope to save user-specified triggered waveforms to a USB memory device for up to 8 hours. www.tektronix.com 3 Data Sheet and waveform data into the stand-alone desktop application or directly into Microsoft Word and Excel. Alternatively, if you prefer not to use your PC, you can simply print your image directly to any PictBridge-compatible printer. Connect Your Bench for Intelligent Debug Every TDS2000C Series oscilloscope ships with an included copy of the Limited Tektronix Edition of National Instrument's LabVIEW SignalExpress for basic instrument control, data logging, and analysis. Easily capture, save, and analyze measurement results with included National Instrument's LabVIEW SignalExpress, Limited Tektronix Edition software. Easy PC Connectivity Easily capture, save, and analyze measurements results by connecting to your PC with the rear-panel USB device port and the included copy of OpenChoice PC Communications Software. Simply pull screen images 4 www.tektronix.com SignalExpress supports the range of Tektronix bench instruments*2 enabling you to connect your entire test bench. You can then access the feature-rich tools packed into each instrument from one intuitive software interface. This allows you to automate complex measurements requiring multiple instruments, log data for an extended period of time, time correlate data from multiple instruments, and easily capture and analyze your results, all from your PC. Only Tektronix offers a connected test bench of intelligent instruments to simplify and speed debug of your complex design. Performance You Can Count On In addition to industry-leading service and support, every TDS2000C Series oscilloscope comes backed with a Lifetime Warranty*1 as standard. *1 Limitations apply. For terms and conditions, visit www.tektronix.com/lifetimewarranty. *2 For a complete listing of Tektronix instruments supported by NI LabVIEW Signal Express, visit www.tektronix.com/signalexpress. Digital Storage Oscilloscopes -- TDS2000C Series Characteristics TDS2000C Series Digital Storage Oscilloscopes Display (QVGA LCD) Bandwidth*3 Channels External Trigger Input Sample Rate on Each Channel Record Length Vertical Resolution Vertical Sensitivity DC Vertical Accuracy Vertical Zoom Maximum Input Voltage Position Range Bandwidth Limit Input Coupling Input Impedance Time Base Range Time Base Accuracy Horizontal Zoom TDS2001C TDS2002C TDS2004C TDS2012C TDS2014C TDS2022C TDS2024C TFT TFT TFT TFT TFT TFT TFT 50 MHz 2 70 MHz 2 70 MHz 4 100 MHz 2 Included on all models 100 MHz 4 200 MHz 2 200 MHz 4 500 MS/s 1.0 GS/s 1.0 GS/s 2.0 GS/s 2.0 GS/s 2.0 GS/s 2.0 GS/s 2.5k points at all time bases on all models 8 bits 2 mV to 5 V/div on all models with calibrated fine adjustment 3% on all models Vertically expand or compress a live or stopped waveform 300 VRMS CAT II; derated at 20 dB/decade above 100 kHz to 13 Vp-p AC at 3 MHz 5 ns to 50 s/div 5 ns to 50 s/div 2 mV to 200 mV/div +2 V >200 mV to 5 V/div +50 V 20 MHz for all models AC, DC, GND on all models 1 M in parallel with 20 pF 5 ns to 50 s/div 2.5 ns to 50 s/div 2.5 ns to 50 s/div 50 ppm 2.5 ns to 50 s/div 2.5 ns to 50 s/div Horizontally expand or compress a live or stopped waveform I/O Interfaces USB Ports USB host port on front panel supports USB flash drives USB device port on back of instrument supports connection to PC and all PictBridge-compatible printers Optional GPIB Nonvolatile Storage Reference Waveform Display Waveform Storage without USB Flash Drive Maximum USB Flash Drive Size Waveform Storage with USB Flash Drive Setups without USB Flash Drive Setups with USB Flash Drive Screen Images with USB Flash Drive Save All with USB Flash Drive (2) 2.5k point reference waveforms (2) 2.5k point (2) 2.5k point (4) 2.5k point (2) 2.5k point (4) 2.5k point (2) 2.5k point (4) 2.5k point 64 GB 96 or more reference waveforms per 8 MB 10 front-panel setups 4000 or more front-panel setups per 8 MB 128 or more screen images per 8 MB (the number of images depends on file format selected) 12 or more Save All operations per 8 MB A single Save All operation creates 3 to 9 files (setup, image, plus one file for each displayed waveform) *3 Bandwidth is 20 MHz at 2 mV/div, all models. www.tektronix.com 5 Data Sheet Acquisition Modes Waveform Math Mode Description Characteristic Description Peak Detect High-frequency and random glitch capture. Captures glitches as narrow as 12 ns (typical) at all time base settings from 5 s/div to 50 s/div Sample data only Waveform averaged, selectable: 4, 16, 64, 128 Use the Single Sequence button to capture a single triggered acquisition sequence At acquisition time base settings of >100 ms/div Operators FFT Add, Subtract, Multiply, FFT Windows: Hanning, Flat Top, Rectangular 2048 sample points Sample Average Single Sequence Roll Sources 2-channel models CH1 - CH2, CH2 - CH1, CH1 + CH2, CH1 x CH2 4-channel models CH1 - CH2, CH2 - CH1, CH3 - CH4, CH4 - CH3, CH1 + CH2, CH3 + CH4, CH1 x CH2, CH3 x CH4 Autoset Menu Trigger System Characteristic Description Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems, with undo Autoset. Trigger Modes Auto, Normal, Single Sequence Signal Type Autoset Menu Choices Square Wave Sine Wave Video (NTSC, PAL, SECAM) Single Cycle, Multicycle, Rising or Falling Edge Single Cycle, Multicycle, FFT Spectrum Field: All, Odd, or Even Line: All or Selectable Line Number Trigger Types Trigger Description Edge (Rising/Falling) Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject Trigger on all lines or individual lines, odd/even or all fields from composite video, or broadcast standards (NTSC, PAL, SECAM) Trigger on a pulse width less than, greater than, equal to, or not equal to, a selectable time limit ranging from 33 ns to 10 s Video Pulse Width (or glitch) Trigger Source Characteristic Description 2-channel Models 4-channel Models CH1, CH2, Ext, Ext/5, AC Line CH1, CH2, CH3, CH4, Ext, Ext/5, AC Line Trigger View Displays trigger signal while Trigger View button is depressed. Trigger Signal Frequency Readout Provides a frequency readout of the trigger source. Autorange Automatically adjust vertical and/or horizontal oscilloscope settings when probe is moved from point to point, or when the signal exhibits large changes. Display Characteristics Characteristic Description Display Interpolation Display Types Persistence Format QVGA Active Color TFT Sin(x)/x Dots, vectors Off, 1 s, 2 s, 5 s, infinite YT and XY Multiple-language User Interface and Context-sensitive Help Characteristic Description Languages Available English, French, German, Italian, Japanese, Korean, Portuguese, Russian*4, Simplified Chinese, Spanish, Traditional Chinese *4 Requires Russian firmware, indicated by "RUS" suffix. Cursors Characteristic Description Types Measurements Amplitude, Time T, 1/T, V Automatic Waveform Measurements Period, Frequency, +Width, -Width, Rise Time, Fall Time, Max, Min, Peak-to-Peak, Mean, RMS, Cycle RMS, Cursor RMS, Duty Cycle, Phase, Delay 6 www.tektronix.com Environmental and Safety Characteristic Temperature Operating Nonoperating Humidity Operating and nonoperating Altitude Operating and nonoperating Electromagnetic Compatibility Safety Description 0 to +50 C -40 to +71 C Up to 80% RH at or below +40 C Up to 45% RH up to +50 C Up to 3,000 m Meets Directive 2004/108/EC, EN 61326-2-1 Class A; Australian EMC Framework UL61010-1:2004, CSA22.2 No. 61010-1:2004, EN61010-1:2001, IEC61010-1:2001 Digital Storage Oscilloscopes -- TDS2000C Series Physical Characteristics Standard Accessories Instrument Dimensions mm in. Width Height Depth 326.3 158.0 124.2 12.85 6.22 4.89 Weight kg lb. Instrument Only With accessories 2.0 2.2 4.4 4.9 Instrument Shipping Package Dimensions mm in. Width Height Depth 476.2 266.7 228.6 18.75 10.5 9.0 RM2000B Rackmount mm in. Width Height Depth 482.6 177.8 108.0 19.0 7.0 4.25 Accessory Description Passive Probes TPP0101: 100 MHz passive probe for TDS2001C/TDS2002C/TDS2004C Power Cord NIM/NIST Documentation OpenChoice PC Communications Software National Instruments SignalExpress Tektronix Edition Interactive Measurement Software - Base Version Ordering Information Limited Lifetime Warranty*5 Models Model Description TDS2001C TDS2002C TDS2004C TDS2012C TDS2014C TDS2022C TDS2024C 50 MHz, 2 Ch, 500 MS/s, TFT DSO 70 MHz, 2 Ch, 1 GS/s, TFT DSO 70 MHz, 4 Ch, 1 GS/s, TFT DSO 100 MHz, 2 Ch, 2 GS/s, TFT DSO 100 MHz, 4 Ch, 2 GS/s, TFT DSO 200 MHz, 2 Ch, 2 GS/s, TFT DSO 200 MHz, 4 Ch, 2 GS/s, TFT DSO TPP0201: 200 MHz passive probe for TDS2012C/TDS2014C/TDS2022C/TDS2024C (Please specify plug option) Traceable Certificate of Calibration User Manual (Please specify preferred language option) Enables fast and easy communication between a Windows PC and the TDS2000C Series using USB. Transfer and save settings, waveforms, measurements, and screen images A fully interactive measurement software environment optimized for the TDS2000C Series. Enables you to instantly acquire, generate, analyze, compare, import, and save measurement data and signals using an intuitive drag-and-drop user interface that does not require any programming. Standard TDS2000C Series support for acquiring controlling, viewing, and exporting your live signal. A 30-day trial period of the Professional Version provides additional signal processing, advance analysis, mixed signal, sweeping, limit testing, and user-defined step capabilities. Order SIGEXPTE for permanent Professional Version capability Covers labor and parts for defects in materials and workmanship for a minimum of 10 years, excluding probes and accessories*6 *5 Lifetime is defined as 5 years after Tektronix discontinues manufacturing the product, but the warranty length shall be at least ten years from date of original purchase. Lifetime warranty is nontransferable, proof of original purchase is required. Limitations apply. For terms and conditions visit www.tektronix.com/lifetimewarranty. *6 Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the data sheet of each probe and accessory model for its unique warranty and calibration terms. Power Plug Options Option Description A0 A1 A2 A3 A5 A6 A10 A11 A99 North America Universal Euro United Kingdom Australia Switzerland Japan China India No power cord or AC adapter www.tektronix.com 7 Data Sheet User Manual Options Recommended Probes Translated front-panel overlays included with their respective user manuals. Probe Option Description L0 L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 English manual French manual Italian manual German manual Spanish manual Japanese manual Portuguese manual Simple Chinese manual Standard Chinese manual Korean manual Russian manual Recommended Accessories Accessory Description TEK-USB-488 SIGEXPTE GPIB-to-USB converter National Instruments SignalExpress Tektronix Edition Interactive Measurement Software - Professional Version Soft Carrying Case for Instrument Hard Plastic Carrying Case for Instrument (requires AC2100) Rackmount Kit Programmer Manual - English Only Service Manual - English Only USB host to device cable, 3 ft. long AC2100 HCTEK4321 RM2000B 071-1075-xx 071-1828-xx 174-4401-xx Description TPP0101 10X Passive Probe, 100 MHz bandwidth TPP0201 10X Passive Probe, 200 MHz bandwidth P2220 1X/10X Passive Probe, 200 MHz bandwidth P6101B 1X Passive Probe (15 MHz, 300 VRMS CAT II rating) P6015A 1000X High-voltage Passive Probe (75 MHz) P5100 100X High-voltage Passive Probe (250 MHz) P5200 High-voltage Active Differential Probe (25 MHz) P6021 15 A, 60 MHz AC-current Probe P6022 6 A, 120 MHz AC-current Probe A621 2000 A, 5 to 50 kHz AC-current Probe A622 100 A, 100 kHz AC/DC Current Probe/BNC TCP303/TCPA300 150 A, 15 MHz AC/DC Current Probe/Amplifier TCP305/TCPA300 50 A, 50 MHz AC/DC Current Probe/Amplifier TCP312/TCPA300 30 A, 100 MHz AC/DC Current Probe/Amplifier TCP404XL/TCPA400 500 A, 2 MHz AC/DC Current Probe/Amplifier Service Options*6 Option Description C3 C5 D1 D3 D5 CA1 Calibration Service 3 Years Calibration Service 5 Years Calibration Data Report Calibration Data Report 3 Years (with Opt. C3) Calibration Data Report 5 Years (with Opt. C5) Provides a single calibration event or coverage for the designated calibration interval, whichever comes first *6 Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the data sheet of each probe and accessory model for its unique warranty and calibration terms. Service Offerings (Available after purchase) Option Description TDSxxxxC-CA1 Provides a single calibration event or coverage for the designated calibration interval, whichever comes first Product(s) are manufactured in ISO registered facilities. Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats. 8 www.tektronix.com Digital Storage Oscilloscopes -- TDS2000C Series www.tektronix.com 9 Data Sheet 10 www.tektronix.com Digital Storage Oscilloscopes -- TDS2000C Series www.tektronix.com 11 Data Sheet Contact Tektronix: ASEAN / Australasia (65) 6356 3900 Austria 00800 2255 4835* Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium 00800 2255 4835* Brazil +55 (11) 3759 7600 Canada 1 800 833 9200 Central East Europe, Ukraine, and the Baltics +41 52 675 3777 Central Europe & Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France 00800 2255 4835* Germany 00800 2255 4835* Hong Kong 400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835* Japan 81 (3) 6714 3010 Luxembourg +41 52 675 3777 Mexico, Central/South America & Caribbean (52) 56 04 50 90 Middle East, Asia, and North Africa +41 52 675 3777 The Netherlands 00800 2255 4835* Norway 800 16098 People's Republic of China 400 820 5835 Poland +41 52 675 3777 Portugal 80 08 12370 Republic of Korea 001 800 8255 2835 Russia & CIS +7 (495) 7484900 South Africa +41 52 675 3777 Spain 00800 2255 4835* Sweden 00800 2255 4835* Switzerland 00800 2255 4835* Taiwan 886 (2) 2722 9622 United Kingdom & Ireland 00800 2255 4835* USA 1 800 833 9200 * European toll-free number. If not accessible, call: +41 52 675 3777 Updated 25 May 2010 For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tektronix.com Copyright (c) Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies. 20 Sep 2010 www.tektronix.com 3GW-25645-0