2
Continuous current limit curve
A = Devices mounted with 2 cm distance
B = Devices mounted without distance
Diagr am switching dela y
Switching delay t M:
When the voltage changes fast on the measur ing input, the arithmetic
mean value can only adjust after a short delay.
Example:
F = F = = 1,26
U applied = 190 V
U setting = 240 V
according to diagr am:
tMon = approx . 800 ms
tMoff = appro x. 100 ms
Output
Contacts
BA 9043: 2 changeover contacts
AA 9943.11: 1 changeover contact
AA 9943.12: 2 changeover contacts
Thermal current Ith:6 A; see diagramm
Continuous current limit curve
Switching capacity
to AC 15
NO contact: 3 A / AC 230 V IEC/EN 60 947-5-1
NC contact: 1 A / AC 230 V IEC/EN 60 947-5-1
Electrical life IEC/EN 60 947-5-1
to AC 15 at 3 A, AC 230 V: 3 x 10 5 switching cycles
Short circuit strength
max. fuse rating: 4 A gL IEC/EN 60 947-5-1
Mechanical life: > 30 x 106 switching cycles
General data
Operating mode: Continuous operation
Temperature range: - 20 ... + 60°C
Clearance and creepage
distances
overvoltage category /
contamination level: 4 kV / 2 IEC 60 664-1
EMC
Electrostatic discharge: 8 kV (air) IEC/EN 61 000-4-2
HF irradiation: 10 V/m IEC/EN 61 000-4-3
Fast transients: 2 kV IEC/EN 61 000-4-4
Surge voltages
between
wires for power supply: 1 kV IEC/EN 61 000-4-5
between wire and ground: 2 kV IEC/EN 61 000-4-5
HF wire guided: 10 V IEC/EN 61 000-4-6
Interference suppression: Limit value class B EN 55 011
Degree of protection: Housing: IP 40 IEC/EN 60 529
Terminals: IP 20 IEC/EN 60 529
Housing: Thermoplastic with V0 behaviour
according to UL subject 94
Vibration resistance: Amplitude 0,35 mm IEC/EN 60 068-2-6
frequency 10 ... 55 Hz
Climate resistance: 20 / 060 / 04 IEC/EN 60 068-1
Terminal designation: DIN EN 50 005
Wire connection: 2 x 2,5 mm2 solid or
2 x 1,5 mm2 stranded wire with sleeve
DIN 46 228-1/-2/-3/-4
Wire fixing: Flat terminals with self-lifting
clamping piece IEC/EN 60 999-1
Mounting: DIN rail IEC/EN 60 715
Weight
BA 9043: 310 g
AA 9943: 300 g
Dimensions
Width x height x depth
BA 9043: 45 x 73 x 132 mm
AA 9943: 45 x 77 x 127 mm
Technical data
Accessories
AA 9943:
K 70-34 Cov er
Characteristics
U applied
U setting 240 V
190 V
t [s]
1,0
0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2
1,2
1,4
1,6
1,8
2,0
F
M6866_a
x off
xon
Variants
AA 9943/001: without neutral
AA 9943/175: earth quake proof
BA 9043/001: without neutral
BA 9043/002: with neutral, adjustable time dela y
tv = 0,5 ... 10 sec
BA 9043/003: without neutral, adjustab le time delay
tv = 0,5 ... 10 sec
Standard type
BA 9043 3/N AC 400 / 230 V 50 ... 400 Hz
Article number: 0039676 stock item
•f or 3p4w systems
•Nominal voltage UN: 3/N A C 400 / 230 V
•Output: 2 changeov er contacts
•Width: 45 mm
Variants
Ordering example f or Variants
BA 9043 /_ _ _ 3/N AC 400/230 V 50 ... 400 Hz
Nominal frequency
Nominal voltage
Variant, if required
Type
AA 9943 .11 /_ _ _ 3/N AC 400/230 V 50 ... 400 Hz
Nominal frequency
Nominal voltage
Variant, if required
Contact
Type
I (A)
ambient temperature
contact current
M6865_a
1
-20 0 204060
A
B
T (°C)
2
3
4
5
6