1
Time control technique
Multifunction relay MK 7850N/200
multitimer
All technical data in this list relate to the state at the moment of edition. We reserve the right
for technical improvements and changes at any time. MK 7850N/200 / 11.09.06 e
Approvals and marking
Application
Time-dependent controllers
Indicators
green LED: on when voltage connected
yellow LED "R/t": shows status of output relay and time
delay:
-Continuously off: output relay not active;
no time delay
-Continuously on: output relay active;
no time delay
-Flashing (short on, long off) output relay not active;
time delay
-Flashing (long on, short off) output relay active;
time delay
A 0239280
* see variants
Canada / USA
*
According to IEC/EN 61 812-1
8 functions settable via rotational switch:
- Delay on energisation (AV)
- Fleeting on make (EW)
- Delayed pulse (IE)
- Flasher, start with pulse (BI)
- Delay on de-energisation (RV)
- Pulse forming function (IF)
- Fleeting on break (AW)
- Delay on energisation and de-energisation (AV / RV)
8 time ranges from 0,02 s to 300 h selectable via rotational switches
Voltage range AC/DC 12 ... 240 V
With time interruption / time adding input for all functions
Adjustment aid for quick setting of long time values
Suitable for 2-wire proximity sensor control
2 changeover contacts, one programmable as instantaneous contact
LED indicators for operation, contact position and time delay
Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
as option with plugable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
22,5 mm width
MK 7850N/500: as MK 7850N/200 but with
2 additional functions:
- Cyclic timer, start with break (TP)
- Fleeting on make and break (EW / AW)
second time setting t2 for functions
- Cyclic timer, start with pulse (TI) or break (TP), based on the
separate setting of pulse and break time the flasher function
can be used as cyclic timer
- Fleeting on make and break (EW/AW)
- Delay on energisation and de-energisation (AV / RV)
- Delay pulse (IE) and setting of pulse length
Connection facility for 2 external potentiometers
Now with selectable
Plugin technology
MK 7850N/200
MK _ _ _ _N P_
Terminal block
with cage clamp terminals
(PC / plugin cageclamp)
Terminal block
with screw terminals
(PS / plugin screw)
Notes
Removing the terminal blocks with cage clamp terminals
1. The unit has to be disconnected.
2. Insert a screwdriver in the side recess of the front plate.
3. Turn the screwdriver to the right and left.
4. Please note that the terminal blocks can only be mounted on the
belonging plug in terminations.
Options with plugable terminal blocks
2
Function diagram
UH
A1-A2
UH
A1-A2
USt
B1-A2
USt
B1-A2
AV
position function switch
RV
EW
IF
IE
AW
BI
AV/RV
1
5
2
6
3
7
4
8
0
0
0
0
15-16
15-16
15-16
15-16
15-16
15-16
15-16
15-16
UN
UN
UN
UN
15-18
15-18
15-18
15-18
15-18
15-18
15-18
15-18
ta
t=ta+tb+tc
t=ta+tb+tc
t=ta+tb+tc
t=ta+tb+tc
tbtctd
tetf
t
t
t
t
tt t
M8290
t
t
t
tt
tt
t
t
t
tt
0,5s
0,5s + td
t=te+t
f
Function diagram
UH
A1-A2
UH
A1-A2
USt
B1-A2
USt
B1-A2
AV
RV
EW
IF
IE
S1: A*
IE
S1: B*
TI
S1: A*
TP
S1: B*
AW
S1: A*
EW/AW
S1: B*
AV/RV
*) A and B indicate the position of function slide switch S1
1
5
2
6
3
7
4
8
0
0
0
0
15-16
15-16
15-16
15-16
15-16
15-16
15-16
15-16
15-16
15-16
15-16
UN
UN
UN
UN
15-18
15-18
15-18
15-18
15-18
15-18
15-18
15-18
15-18
15-18
15-18
ta
t1=ta+tb+tc
t1=ta+tb+tc
t1=ta+tb+tc
t1=ta+tb+tc
t1=ta+tb+tc
t2=ta+tb+tg
t2=te+tf
t2=te+tf
t1=th+ti
tbtctd
te
th
tg
tf
ti
t1
t1
t1
t1t1
t2
t2
t1
t1
t1
t1
t1
t1
t2
t2
M8291
t1
t2
t2
t1
t2
t1
t1
t1
t1
t1t1
t1
t1
t2
t2
0,5s
0,5s+t
d
position function switch
MK 7850N/200
... = position of function switch
AV = Delay on energisation
EW = Fleeting on make
IE = Delayed pulse
BI = Flasher,
start with pulse
RV = Delay on de-energisation
IF = Pulse forming function
AW = Fleeting on break
AV/RV = Delay on energisation and
de-energisation
MK 7850N/500
... = position of function switch
AV = Delay on energisation
EW = Fleeting on make
IE = Delayed pulse
S1 in positon A:
t1: adjustable, t2 = 0,5 s fixed
S1 in position B:
t1 and t2 adjustable
TI = Cyclic timer,
start with pulse
S1 in position A
TP = Cyclic timer,
start with break
S1 in position B
RV = Delay on de-energisation
IF = Pulse forming function
AW = Fleeting on break
S1 in position A
EW/AW = Fleeting on make
and break
S1 in position B
AV/RV = Delay on energisation
and de-energisation
3
M8302_a
green LED
on when voltage
connected
slide switch S1
(only with MK7850N/500)
yellow LED
function see
indicators
range selector switch
function setting
time setting t1
time setting t2
(only with MK7850N/500)
Notes
Control of A1-A2 with proximity sensors
The input can be controlled by DC 3 wire or AC/DC 2 wire proximity
sensors. For operating voltage > 24 V and usage of sensors without
built-in short circuit protection a protection resistor on A1 is
recommendend to reduce the inrush current. The dimension is as
follows:
Rv operating voltage / max. switching current of sensor
The series resistor must not be selected higher than necessary.
Max. values are:
Operating voltage: 48 V 60 V 110 V 230 V
Series resistor Rv max: 270 390 680 1,8 k (1 W)
Instantaneous contact
By external wire links the output function of the device can be altered
from 2 delayed contacts to 1 delayed and 1 instantaneous contact.
The instantaneous contact switches when the operating voltage is
connected. To terminals X1 and X2 no other voltage potentials must
be connected, as the unit might be damaged.
Adjustment assistance
The flashing period of the yellow LED is 1 s ± 4 % and can be used to
adjust the time. Especially on the lower end of scale and for long times
it is suitable as the multiplication factors between the different time
ranges are exact without tolerance.
Example:
The required time is 40 min. It has to be adjusted within range
3 ... 300 min.The time check takes too long as several timing cycles
would be necessary for a precise value. For faster adjustment the
setting is made to 0.03 ... 3 min. On this range the potentiometer should
be set to 0.4 min (= 24 sec.). With the right potentiometer setting the
LED must show 24 flashing cycles. After that the time range is switched
over to
3 ... 300 min. and the setting is complete.
Time interruption / time adding with B1
With the functions AV, EW, IE and BI the time delay can be interrupted
by controlling input B1 (+) with control voltage. Removing the control
signal will continue the timing cycle (time addition).
Setting
Notes
Control input B1
The functions RV, IF, AW, AV / RV have to be controlled via input B1
(+) with voltage against A2. The control signal could be the same as
the auxiliary/control voltage of A1 or any other voltage between 12 and
240 V AC or DC. Operating a parallel load between B1 and A2 is also
possible.
If with function IF the inputs A1 and B1 are controlled simultaneously
a pulse with the adjusted length is started. With the variant MK7850N/
500 the output pulse can be disabled by setting the slide switch in
Position "B".
Time interruption and time addition with X3
On all functions, also with RV,IF, AW (EW/AW) and AB/RV the time
delay can be interrupted during timing by bridging the terminals
X2 - X3. By opening the bridge the time continues (time addition).
While X2 and X3 are bridged the control input is disabled and the yellow
LED remains in the state it had at stop. No external voltage must be
connected to X2 and X3 as the unit may be damaged.
Remote potentiometers
Both settings on variant MK 7850N/500 can also be made by remote
potentiometers of 10 kOhms:
- terminals Z1 - Z2: potentiometer for time t1
- terminals Z2 - Z3: potentiometer for time t2
When connecting a remote potentiometer the corresponding
potentiometer has to be set to min. If no remote potentiometers are
required the terminals Z1-Z2 resp. Z2-Z3 have to be linked.
The wires to the remote potentiometers should be installed separately
from the lines with mains voltage. If this is not possible, a screened
cable is recommendet where the shield is connected to Z2.
To terminals Z1, Z2 and Z3 no external voltage must be connected,
as the unit might be damaged.
Additional function
With the variant MK7850N/500 additional features can be selected for
the functions position 3, 4 and 7 using the slide switch S1 on the relay
front in position "B". At the same time a second time setting t2 is
available on the lower potentiometer (see function diagram) the time
range is the same as for t1.
Circuit diagrams
A1
26
22
16
15
28
24
18
25
21
B1
(+)
X1 X2
X3
A2
M8100_a
A1 B1
A2
15
16 18
25
21
26
22 28
24
A1
26
22
16
15
28
24
18
25
21
B1
(+)
X1 X2
A2
Z1 Z2 Z3
M8101_a
A1 B1 Z1
Z1 t1
t2
Z2
Z3
A2 Z2 Z3
15
16 18
25
21
26
22 28
24
X3
MK 7850N.82/200
MK 7850N.82/500
A1
26
22
16
15
28
24
18
25
21
B1
(+)
X1 X2
A2
Z1 Z2
M8676_a
A1 B1 Z1
Z1 tZ2
A2 Z2
15
16 18
25
21
26
22 28
24
X3
MK 7850N.82/300
4
Technical data
Time circuit
Time ranges: 8 time ranges in one unit, settable
via rotational switch
0.02 ... 1 s 0.3 ... 30 min
0.06 ... 6 s 3 ... 300 min
0.3 ... 30 s 0.3 ... 30 h
0.03 ... 3 min 3 ... 300 h
Time setting t1, t2: continuous, 1:100 on relative scale
(t2 only at MK 7850N/500)
Recovery time:
at DC 24 V: approx. 15 ms
at DC 240 V: approx. 50 ms
at AC 230 V: approx. 80 ms
Repeat accuracy: ± 0.5 % of selected
end of scale value + 20 ms
Voltage and
temperature influence: < 1 % with the complete
operating range
Input
Nominal voltage UN:AC/DC 12 ... 240 V
Voltage range: 0.8 ... 1.1 UN
Release voltage (A1/A2)
Delayed contact
AC 50 Hz: approx. 7,5 V
DC: approx. 7 V
Instantaneous contact
AC 50 Hz: approx. 3 V
DC: approx. 3.3 V
Max. permitted residual
current with 2-wire proximity
sensor control (A1-A2)
up to AC/DC 150 V: AC resp. DC 5 mA
up to AC/DC 264 V: AC resp. DC 3 mA
Control current B1: approx. 1mA, over complete voltage range
Min. on/off time of
control input B1(+):
AC 50 Hz: approx. 15 ms / ca. 60 ms
DC: approx. 5 ms / ca. 60 ms
Release voltage (B1/A2)
AC 50 Hz: approx. 3.5 V
DC: approx. 3 V
Nominal power consumption
AC 12 V: approx. 1.5 VA
AC 24 V: approx. 2 VA
AC 240 V: approx. 3 VA
DC 12 V: approx. 1 W
DC 24 V: approx. 1 W
DC 240 V: approx. 1 W
Nominal frequency: 45 ... 400 Hz
Output
Contacts
MK 7850N.82: 2 changeover contacts, one
programmable as instantaneous
contact:
without bridge X1-X2: 25-26-28 delayed changeover contact
with bridge X1-X2: 21-22-24 instantaneous contact at
UN on A1-A2
Thermal current Ith:2 x 4 A
Switching capacity
to AC 15
NO contact: 3 A / AC 230 V IEC/EN 60 947-5-1
NC contact: 1 A / AC 230 V IEC/EN 60 947-5-1
to DC 13: 1 A / DC 24 V IEC/EN 60 947-5-1
Electrical life IEC/EN 60 947-5-1
to AC 15 at 1 A, AC 230 V: 1,5 x 105 switching cycles
Short circuit strength
max. fuse rating: 4 A gL IEC/EN 60 947-5-1
Mechanical life: 30 x 106 switching cycles
General data
Operating mode: Continuous operation
Temperature range: - 40 ... + 60 °C
Clearance and creepage
distances
overvoltage category / 4 kV / 3 IEC 60 664-1
contamination level: (4 kV / 2 at MK 7850N.82/61)
EMC
Electrostatic discharge: 8 kV (air) IEC/EN 61 000-4-2
HF-irradiation: 30 V / m IEC/EN 61 000-4-3
Fast transients: 2 kV IEC/EN 61 000-4-4
Surge voltages
between
wires for power supply: 2 kV IEC/EN 61 000-4-5
between wire and ground: 4 kV IEC/EN 61 000-4-5
HF-wire guided: 10 V IEC/EN 61 000-4-6
Interference suppression: Limit value class B EN 55 011
Degree of protection
Housing: IP 40 IEC/EN 60 529
Terminals: IP 20 IEC/EN 60 529
Housing: Thermoplastic with V0 behaviour
according to UL subject 94
Vibration resistance: Amplitude 0,35 mm,
frequency 10 ... 55 Hz,IEC/EN 60 068-2-6
Climate resistance: 40 / 060 / 04 IEC/EN 60 068-1
Terminal designation: EN 50 005
Wire connection DIN 46 228-1/-2/-3/-4
Screw terminals
(integrated): 1 x 4 mm2 solid or
1 x 2.5 mm2 stranded ferruled or
2 x 1.5 mm2 stranded ferruled or
2 x 2.5 mm2 solid
Insulation of wires
or sleeve length: 8 mm
Plugin with screw terminals
max. cross section
for connection: 1 x 2.5 mm2 solid or
1 x 2.5 mm2 stranded ferruled
Insulation of wires
or sleeve length: 8 mm
Plugin with cage
clamp terminals
max. cross section
for connection: 1 x 4 mm2 solid or
1 x 2.5 mm2 stranded ferruled
min. cross section
for connection: 0.5 mm2
Insulation of wires
or sleeve length: 12 ±0.5 mm
Wire fixing: Plus-minus terminal screws M 3.5
box terminals with wire protection or
cage clamp terminals
Wire fixing: Box terminals with wire protection
Mounting: DIN rail IEC/EN 60 715
Weight: approx. 150 g
Dimensions
Width x heigth x depth
MK 7850N/200: 22.5 x 90 x 97 mm
MK 7850N/200 PC: 22.5 x 111 x 97 mm
MK 7850N/200 PS: 22.5 x 104 x 97 mm
Technical data
5
Connection examples
M5794
MK7850N
S1
L(+)
AC/DC12...240V
N(-)
A1 X2
X3
A2
S2 B1(+)
voltfree
control contact
(stop function)
M8127
MK7850N
S1 S2
L(+)
N(-)
A1
A2
B1(+)
Control with parallel connected load
Connection with 2 different control voltages.
M8292
MK7850N
S1
L(+)
N(-)
A1
A2
B1(+)
DC24V
AC/DC12...240V
e.g. PLC
semi-
conductor
output
Accessories
AD 3: External potentiometer 10 k
The external potentiometer is used for
remote setting of the time delay. The
internal potentiometer of the timer must
be set to min. time delay.
Degree of protection
front side: IP 60
MK 7850N.82/200 AC/DC 12 ... 240 V
Article number: 0054050
Output: 2 changeover contacts, one
programmable as instantaneous
contact
Nominal voltage UN: AC/DC 12 ... 240 V
Time ranges: from 0.02 s ... 300 h
Width: 22.5 mm
Standardtype
MK 7850N.82/61: With UL-approval (Canada/USA)
MK 7850N.82/500: With 2 additional functions selectable via slide
switch S1:
- Cyclic timer, start with break (TP)
- Fleeting on make and break (EW/AW)
second time setting t2, connection facility
for 2 remote potentiometers 10 k to adjust
t1 and t2
MK7850.82/300: connection facility for 1 remote potentiometer
10 k
Ordering example for variant
MK 7850N .82 PS /_ _ _ AC/DC 12 ... 240 V
Nominal voltage
Variant
Type of terminals
without indication:
terminal blocks fixed,
with screw terminals
PC (plugin cage clamp):
plugable terminal
blocks with cage
clamp terminals
PS (plugin screw):
plugable terminal
blocks with screw
terminals
Contacts
Type
Variants
6
E. DOLD & SÖHNE KG • D-78114 Furtwangen
e-mail dold-relays
@dold.com • internet http://www.dold.com