Myrra - EI 30-15,5 SERIE 44000 2-2,4 VA
MYRRA - SERIE 44000 EI 30-15,5 2-2,4 VA
* Vacuum filling
* Two compartments bobbins
* Self-extinguishing plastics UL 94 VO
* Degree of protection IP 00
* 100 grams weight
* Resin class B CEI 85 (20 000h testing to CEI 126)
* Inherently short-circuits proof
* Insulation voltage 4 KV (6 KV MYRRA test)
* 30 V model is VDE EN 60742 certified (Production
on request)
* 100% tested production
* Certification : CCA procedure on request
* To be noted : 2 * 18 V and 2 * 24 V models are non
approved. Protection transformers according to EN
60742 circuit isolation tranformer.
EI 30-15,5 SERIE 44000 2-2,4 VA
Primary Voltage 117 V
Reference Secondary
Voltage
V
Secondary
Currant
m A
No-load
Voltage
V
Ambient,
Temperature
C
Rating
VA
44133 6 333 10,4 T 70 B 2
44134 9 222 15,5 T 70 B 2
44135 12 167 20,7 T 70 B 2
44136 15 133 25,8 T 70 B 2
44137 18 111 30,8 T 70 B 2
44138 24 83 41,4 T 70 B 2
44139 2 x 6 2 x 167 2 x 10,4 T 70 B 2
44140 2 x 9 2 x 111 2 x 15,4 T 70 B 2
44141 2 x 12 2 x 83 2 x 20,7 T 70 B 2
44142 2 x 15 2 x 67 2 x 25,8 T 70 B 2
44143 2 x 18 2 x 56 2 x 30,8 T 70 B 2
44144 2 x 24 2 x 42 2 x 42 T 70 B 2
44750 6 383 10,5 T 50 B 2,3
44751 9 256 15,5 T 50 B 2,3
44752 12 192 21 T 50 B 2,3
44753 15 153 25,3 T 50 B 2,3
44754 18 128 31 T 50 B 2,3
44755 24 96 42 T 50 B 2,3
44756 2 x 6 2 x 192 2 x 10,5 T 50 B 2,3
44757 2 x 9 2 x 128 2 x 15,5 T 50 B 2,3
44758 2 x 12 2 x 96 2 x 21 T 50 B 2,3
44759 2 x 15 2 x 77 2 x 24,5 T 50 B 2,3
44760 2 x 18 2 x 64 2 x 31 T 50 B 2,3
44761 2 x 24 2 x 48 2 x 42 T 50 B 2,3
44762 6 400 10,5 T 40 B 2,4
44763 9 267 15,5 T 40 B 2,4
http://www.myrra.ie/44000-4.html (1 of 3)5/22/2007 3:38:54 PM
Myrra - EI 30-15,5 SERIE 44000 2-2,4 VA
44764 12 200 21 T 40 B 2,4
44765 15 160 25,3 T 40 B 2,4
44766 18 133 31 T 40 B 2,4
44767 24 100 42 T 40 B 2,4
44768 2 x 6 2 x 200 2 x 10,5 T 40 B 2,4
44769 2 x 9 2 x 133 2 x 15,5 T 40 B 2,4
44770 2 x 12 2 x 100 2 x 21 T 40 B 2,4
44771 2 x 15 2 x 80 2 x 24,5 T 40 B 2,4
44772 2 x 18 2 x 67 2 x 31 T 40 B 2,4
44773 2 x 24 2 x 50 2 x 42 T 40 B 2,4
EI 30-15,5 SERIE 44000 2-2,4 VA
Primary Voltage 230 V
Reference Secondary
Voltage
V
Secondary
Currant
m A
No-load
Voltage
V
Ambient,
Temperature
C
Rating
VA
44121 6 333 10,4 T 70 B 2
44122 9 222 15,5 T 70 B 2
44123 12 167 20,7 T 70 B 2
44124 15 133 25,8 T 70 B 2
44125 18 111 30,8 T 70 B 2
44126 24 83 41,4 T 70 B 2
44127 2 x 6 2 x 167 2 x 10,4 T 70 B 2
44128 2 x 9 2 x 111 2 x 15,4 T 70 B 2
44129 2 x 12 2 x 83 2 x 20,7 T 70 B 2
44130 2 x 15 2 x 67 2 x 25,8 T 70 B 2
44131* 2 x 18 2 x 56 2 x 30,8 T 70 B 2
44132* 2 x 24 2 x 42 2 x 42 T 70 B 2
44667 6 383 10,5 T 50 B 2,3
44668 9 256 15,5 T 50 B 2,3
44669 12 192 21 T 50 B 2,3
44670 15 153 25,3 T 50 B 2,3
44671 18 128 31 T 50 B 2,3
44672 24 96 42 T 50 B 2,3
44673 2 x 6 2 x 192 2 x 10,5 T 50 B 2,3
44674 2 x 9 2 x 128 2 x 15,5 T 50 B 2,3
44675 2 x 12 2 x 96 2 x 21 T 50 B 2,3
44676 2 x 15 2 x 77 2 x 24,5 T 50 B 2,3
http://www.myrra.ie/44000-4.html (2 of 3)5/22/2007 3:38:54 PM
Myrra - EI 30-15,5 SERIE 44000 2-2,4 VA
44487* 2 x 18 2 x 64 2 x 31 T 50 B 2,3
44488* 2 x 24 2 x 48 2 x 42 T 50 B 2,3
44677 6 400 10,5 T 40 B 2,4
44678 9 267 15,5 T 40 B 2,4
44679 12 200 21 T 40 B 2,4
44680 15 160 25,3 T 40 B 2,4
44681 18 133 31 T 40 B 2,4
44682 24 100 42 T 40 B 2,4
44683 2 x 6 2 x 200 2 x 10,5 T 40 B 2,4
44684 2 x 9 2 x 133 2 x 15,5 T 40 B 2,4
44685 2 x 12 2 x 100 2 x 21 T 40 B 2,4
44686 2 x 15 2 x 80 2 x 24,5 T 40 B 2,4
44489* 2 x 18 2 x 67 2 x 31 T 40 B 2,4
44490* 2 x 24 2 x 50 2 x 42 T 40 B 2,4
http://www.myrra.ie/44000-4.html (3 of 3)5/22/2007 3:38:54 PM