Solid State Relays G3M 407
Solid State Relays
G3M
Zero Cross Models Added to Compact,
Low-cost G3M Series
3 and 5A single in-line package SSR
Thin design for high-density PCB applications.
DC input-AC output for up to a 5-A load.
Certified by UL, CSA, and VDE.
Ordering Information
To order: Select the part number and add the desired input voltage rating. (e.g., G3M-203PL DC5)
Note: 1. All models have UL and CSA approvals.
2. TÜV Marking is available for 3 amp versions with reinforced insulation by inserting “-UTU” in place of “-US” in the part number
Example: G3M-203P-UTU-1-4 DC12
3. G3M-205P(L)-VD-1, with reinforced insulation, is approved by UL, CSA and VDE
Isolation Input terminal
pitch
Zero cross
function
Indicator Rated output load
(Applicable output load)
Rated input voltage Model
Phototriac 7.62 mm Yes No 3 A at 100 to 240 VAC
(3 A at 75 to 264 VAC)
5 VDC G3M-203P
12 VDC
24 VDC
5 A at 100 to 240 VAC
(5 A at 75 to 264 VAC)
5 VDC G3M-205P
12 VDC
24 VDC
No 3 A at 100 to 240 VAC
(3 A at 75 to 264 VAC)
5 VDC G3M-203PL
12 VDC
24 VDC
5 A at 100 to 240 VAC
(5 A at 75 to 264 VAC)
5 VDC G3M-205PL
12 VDC
24 VDC
5.08 mm Yes 3 A at 100 to 240 VAC
(3 A at 75 to 264 VAC)
5 VDC G3M-203P-4
12 VDC
24 VDC
5 A at 100 to 240 VAC
(5 A at 75 to 264 VAC)
5 VDC G3M-205P-4
12 VDC
24 VDC
No 3 A at 100 to 240 VAC
(3 A at 75 to 264 VAC)
5 VDC G3M-203PL-4
12 VDC
24 VDC
5 A at 100 to 240 VAC
(5 A at 75 to 264 VAC)
5 VDC G3M-205PL-4
12 VDC
24 VDC
408 Solid State Relays G3M
Specifications
Ratings (at an Ambient Temperature of 25°C)
Input
Note: Each model has 5-VDC, 12-VDC, and 24-VDC input versions.
Output
Characteristics
Approvals
UL Recognized (File No. E64562) / CSA Certified (File No. LR35535) - - Ambient Temp. = 40°C
Rated voltage Operating voltage Impedance Voltage levels
Must operate voltage Must release voltage
5 VDC 4 to 6 VDC 300 Ω ±20% 4 VDC max. 1 VDC min.
12 VDC 9.6 to 14.4 VDC 800 Ω ±20% 9.6 VDC max.
24 VDC 19.2 to 28.8 VDC 1.6 kΩ ±20% 19.2 VDC max.
Model Rated voltage Applicable load
Load voltage range Load current Inrush current
G3M-203P(L)(-4) 100 to 240 VAC 75 to 264 VAC 0.1 to 3 A 45 A (60 Hz, 1 cycle)
G3M-205P(L)(-4) 0.1 to 5 A
Item G3M-203P(L)(-4) G3M-205P(L)(-4)
Operate time 1 ms max. (1/2 of load power source cycle + 1 ms max. for G3M-203P, G3M-205P)
Release time 1/2 of load power source cycle + 1 ms max.
Output ON voltage drop 1.6 V (RMS) max.
Leakage current 1.5 mA (at 200 VAC)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 2,500 VAC, 50/60 Hz for 1 min
Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Malfunction: 1,000 m/s2 (approx. 100G)
Ambient temperature Operating: –30°C to 80°C (with no icing or condensation)
Storage: –30°C to 100°C (with no icing or condensation)
Ambient humidity Operating: 45% to 85%
Weight Approx. 15 g Approx. 25 g
Input Voltage SSR Type Load Rating
5, 12, 24 VDC With Suffixes 203 and
US or UTU
3 A, 250 VAC, Resistive
750 W, 250 VAC Tungsten
1.5 A FLA / 9 A LRA, 250 VAC
With Suffix 205 5 A, 250 VAC, Resistive
1,250 W, 250 VAC Tungsten
2.5 A FLA / 15 A LRA, 250 VAC
Solid State Relays G3M 409
Engineering Data
Load Current vs. Ambient Temperature Inrush Current Immunity
Load Current vs. Ambient Temperature (Close Mounting)
G3M-205 Series (5-A Load)
Thirty Relays are soldered to the PCB at each given spacing.
Continuous power.
6
5
4
3
2
1.5
1
0.5
0
30 20
020 25 40 60 80 100 0
10
20
30
40
50
100
50
30
10 200 500 1,000 5,000
Load current (A)
Ambient temperature (°C)
Inrush peak current (A)
Energized time (ms)
G3M-203P(L)(-4)
Non-repetitive
Reduce the current to 1/2 or less if the
G3M is in repetitive operation.
G3M-203P(L)(-4)
G3M-205P(L)(-4)
G3M-205P(L)(-4)
0.8A L=7.62 mm
1.8A L=12.7 mm
0.8A L=7.62 mm
1.8A L=12.7 mm
1.5A L=12.7 mm
2.0A L=20.37 mm
10
3
6
5
4
3
2
1
010080604020 2502030
0.6A L=7.62 mm
6
5
4
3
2
1
010080604020 2502030
2.5A L=20.37 mm
6
5
4
3
2
1
010080604020 2502030
2.5A L=20.37 mm
L
L
LL
10
3
LL
10
Load current (A)
Ambient temperature (°C)
Load current (A)
Ambient temperature (°C)
Load current (A)
Ambient temperature (°C)
X direction Y direction Z direction
Top
Bottom
Top
Bottom
Top
Bottom
410 Solid State Relays G3M
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Precautions
Protective Element
No overvoltage absorption element is built in. Therefore, if the G3M
is connected to an inductive load, be sure to connect the overvoltage
absorption element.
G3M-203P(L)-4
47.62
4±2
12.7 10.16 0.7 0.4
1.5
(5.08)*
2.54
2.54
*Input terminal pitch for models ending in "-4" is 5.08 mm.
40 max.
20 max.
9 max.
Load
Input voltage
Input Load
Four, 1.2 dia. holes
Terminal Arrangement
(Bottom View)
PCB Dimensions
(Bottom View)
Load power
supply
"-4" type
(4)4123
G3M-205P(L)-4 7.6±0.2
47.62 12.7
4±2
10.16 0.7 0.4
1.65
(5.08)*
40 max.
25 max.
41
23
41
23
Solid State Relays G3M
MEMO
Solid State Relays G3M
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
Cat. No. X301-E-1b Printed in USA
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
09/11 Specifications subject to change without notice
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.