5200 POWER ENTRY MODULES WITH LINE FILTER Plug removal necessary for fuse replacement Inlet filter, front side mounting, fuseholder 5x20 mm Type 5200, Fuseholder 1-pole with spare compartment Type 5200, Fuseholder 1-pole with spare compartment C14 70 C Description Characteristics - Panel Mount: Snap-in or screw-on mounting from front side - 3 Functions: Inlet Protection class I, Fuseholder for fuse-links 5 x 20 mm 1-pole, Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm - Alternative: version without line filter 6200 - All single elements are already wired - Plug removal necessary for fuse-link replacement Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuseholder is accessible from the equipment front - Qualified for use in equipment according IEC/EN 60950 Approvals Weblinks Approvals: http://www.schurter.com/approvals RoHS: http://www.schurter.com/rohs - VDE License Number: 101307 - UL License Number: E72928 Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temp. Climatic Category Degree of Protection Protection Class Terminal Panel Thickness s Material: Housing 1 www.schurter.com 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21acc. to, IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 0.8 mm to 3 mm Thermoplastic, black, UL 94V-0 Appliance-Inlet /-Outlet Fuseholder C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I 1 pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm 5 x 20: 2 W (1 pole) Rated Power Acceptance @ Ta 23 C Power Acceptance @ Ta > 23C Admissible power acceptance at higher ambient temperature see derating curves Line Filter Standard and Medical Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details MTBF > 2'300'000 h acc. to MIL-HB-217 F 5200 POWER ENTRY MODULES WITH LINE FILTER Dimensions Screw-on mounting type 5200 Length 48.7 mm 2.5 34 32 5 43.7 +0.2 0 Snap-in mounting type 5200 Technical Data of Filter-Components Rated Current Filter-Type [A] 2 32 5 43.7 34 Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] R [M ] 1 Standard Version 2 x 11 47 2.2 - 2 Standard Version 2x4 47 2.2 - 4 Standard Version 2 x 1.6 47 2.2 - 6 Standard Version 2 x 0.7 47 2.2 - 8 Standard Version 2 x 0.6 47 2.2 - 10 Standard Version 2 x 0.4 47 2.2 - 1 Medical Version (M5) 2 x 11 47 - 1 2 Medical Version (M5) 2x4 47 - 1 4 Medical Version (M5) 2 x 1.6 47 - 1 6 Medical Version (M5) 2 x 0.7 47 - 1 8 Medical Version (M5) 2 x 0.6 47 - 1 10 Medical Version (M5) 2 x 0.4 47 - 1 www.schurter.com +0.20 0 29 36 max.R3 +0.20 0 3.5 36 +0.50 0 max.R3 29 o 6.3x90 44 36 o 3.5 M3 5200 POWER ENTRY MODULES WITH LINE FILTER Diagrams 5200 Standard version 5200 Medical version 1) Line 2) Load 1) Line 2) Load Derating curves 1-pole Admissible power acceptance in Watt 2.0 1.5 I = 1.0 In I = 0.7 In 1.0 I = < < In 0.5 0.0 0 20 40 60 80 100 Ambient air temperature Ta C Attenuation loss - - - - differential mode Standard version 1A 2A 8A 10 A 4A 6A 4A 6A Medical version (M5) 1A 2A 8A 10 A 3 www.schurter.com _____ common mode 5200 POWER ENTRY MODULES WITH LINE FILTER Variants Socket and fuse-carrier included Rated Current Filter-Type [A] Panel mounting Order Number 1 Standard Version Snap-in 1 pole 5200.0143.1 2 Standard Version Snap-in 1 pole 5200.0243.1 4 Standard Version Snap-in 1 pole 5200.0443.1 6 Standard Version Snap-in 1 pole 5200.0643.1 8 Standard Version Snap-in 1 pole 5200.0843.1 10 Standard Version Snap-in 1 pole 5200.1043.1 1 Standard Version Screw-on 1 pole 5200.0123.1 2 Standard Version Screw-on 1 pole 5200.0223.1 4 Standard Version Screw-on 1 pole 5200.0423.1 6 Standard Version Screw-on 1 pole 5200.0623.1 8 Standard Version Screw-on 1 pole 5200.0823.1 10 Standard Version Screw-on 1 pole 5200.1023.1 1 Medical Version (M5) Snap-in 1 pole 5200.0143.3 2 Medical Version (M5) Snap-in 1 pole 5200.0243.3 4 Medical Version (M5) Snap-in 1 pole 5200.0443.3 6 Medical Version (M5) Snap-in 1 pole 5200.0643.3 8 Medical Version (M5) Snap-in 1 pole 5200.0843.3 10 Medical Version (M5) Snap-in 1 pole 5200.1043.3 1 Medical Version (M5) Screw-on 1 pole 5200.0123.3 2 Medical Version (M5) Screw-on 1 pole 5200.0223.3 4 Medical Version (M5) Screw-on 1 pole 5200.0423.3 6 Medical Version (M5) Screw-on 1 pole 5200.0623.3 8 Medical Version (M5) Screw-on 1 pole 5200.0823.3 10 Medical Version (M5) Screw-on 1 pole 5200.1023.3 Packaging unit 10 Pcs Accessory Description Assorted Covers Cord retaining kits 4 Fuseholder www.schurter.com