Maulflex Helical Conduit, Inner Sheilded Ordering Information MAULFLEX - 6 X X - SM - XX Product Family Name Length in inches Helical Convolex(R) type -6 XLETFE per RT-1162 (see note 8) Add if srength member is required (see note 3) Shield (see note 6) 1. Single layer tinned copper 2. Two layers tinned copper Size number (see table for dimensions) Kevlar(R) is a registered trademark of E.I. du Pont de Nemours & Co. RAYCHEM MOLDED PARTS CUSTOMER DRAWING (c) 2011 Tyco Electronics Corporation. All rights reserved Title: Maulflex Helical Conduit, Inner Sheilded TE Connectivity 305 Constitutional Drive Menlo Park, CA 94025 USA . Tyco Electronics reserves the right to amend this drawing at any time. Users should evaluate the suitability of the product for their application Cage Code: Scale: Size: 06090 None A Document No : MAULFLEX Rev. Date: Rev.: Sheet: 09-JUN-11 C 1 of 2 If this document is printed it becomes uncontrolled. Check for the latest revision. Table 1: Dimensions (inches) Size Number 1 1 Layer Shield (A) Weight Minimum per 100 Feet .240 (6,10) .312 (7,92) .360 (9,14) .480 (12,19) .600 (15,24) .720 (18,29) .840 (21,34) 1.050 (26,67) 1.430 (36,32) 2 3 4 5 6 7 8 9 4.1 (1,86) 5.0 (2,27) 5.8 (2,63) 9.6 (4,35) 11.3 (5,13) 16.6 (7,53) 19.1 (8,66) 28.8 (13,06) 38.4 (17,42) 2 Layer Shield (A) Weight Minimum per 100 Feet .200 (5,08) .270 (6,86) .320 (8,13) .440 (11,18) .560 (14,22) .680 (17,27) .800 (20,32) 1.000 (25,40) 1.375 (34,93) (B) Maximum Bend Radius 7* .510 (12,96) .571 (14,50) .650 (16,51) .770 (19,56) .930 (23,62) 1.073 (27,25) 1.226 (31,14) 1.539 (35,30) 1.975 (50,17) .88 (22,35) .88 (22,35) 1.25 (31,75) 1.50 (38,10) 1.75 (44,45) 2.00 (50,80) 2.37 (60,20) 2.75 (69,85 3.63 (92,20) 6.0 (2,72) 7.2 (3,27) 8.6 (3,90) 13.4 (6,08) 18.0 (8,16) 24.1 (10,93) 27.7 (12,56) 43.6 (19,78) 56.2 (25,49) Helical Convolex (R) Size 3/8 7/16 1/2 5/8 3/4 7/8 1 1-1/4 1-5/8 Notes ; Inches (millimeters) lbs. (kgms) 1. Dimensions in table are in 2. Service rating: -55C (-67F) to + 150C (+302F). 3. Two Kevlar(R) strength members placed longitudinally 180 apart between shield and convolex tubing. These Kelvar strength members are to be a minimum of about 12 inches longer than the convolex tubing with a minimum of 6 inches out each end and stored under the removable tubing. 4. Consult factory for optional configurations. 5. Standard lengths supplied: 4 feet minimum; 24 feet maximum (lengths to be specified when ordering). 6. Shield material, tin coated copper per A-A-59569 and QQ-B-575. 7.* The recommended minimum bend radius that can be achieved without cross sectional area reduction. 8. When used as Maulflex paragraphs 4.3.1, 4.3.2, 4.3.3, 4.3.4, 4.3.5, and Table 2 inside diameter of RT1162 are not applicable. RAYCHEM MOLDED PARTS TE Connectivity 305 Constitutional Drive Menlo Park, CA 94025 USA (c) 2011 Tyco Electronics Corporation. All rights reserved. Tyco Electronics reserves the right to amend this drawing at any time. Users should evaluate the suitability of the product for their application Cage Code: Scale: Size: 06090 None A CUSTOMER DRAWING Title: Maulflex Helical Conduit, Inner Sheilded Document No : MAULFLEX Rev. Date: Rev.: Sheet: 09-JUN-11 C 2 of 2 If this document is printed it becomes uncontrolled. Check for the latest revision. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TE Connectivity: MAULFLEX615-SM-288IN