104 10/02
Applications
■Overcurrent protection for line cards
Features
■Compliant with ITU-T K20, K21, K45
– basic level lightning surges (10/700 µs)
– basic level power induction (600 V, 1 A, 0,2 s)
– power contact criteria A/B (230 V, 15 min.)
■Suitable for continous connection to mains voltages
of 110/230 VAC in tripped (high ohmic) condition
■Narrow resistance tolerance
Options
■Alternative tolerances and resistances on request
Delivery mode
■Cardboard tape, reeled (standard) or in AMMO pack (on request); cardboard strips (on request)
■Exception: B 1610, cardboard strips (standard), cardboard tape or AMMO pack on request
Dimensional drawings
Dimensions (mm)
Type Leads bmax hmax smax Type Leads bmax hmax smax
B 1610 kinked 10,2 13,1 5,0 B 1008 kinked 8,2 12,1 4,0
B 1042 kinked 8,2 12,1 4,0 B 1008 straight 8,2 8,2 4,0
B 1042 straight 8,2 8,2 4,0 B 1603 kinked 10,2 12,6 5,0
B 1045 kinked 6,6 9,5 4,0 B 1184 kinked 8,2 12,1 5,0
B 1045 straight 6,6 6,6 4,0 B 1184 straight 8,2 8,2 5,0
1) C 1077 coated type C 10771) kinked 8,5 12,5 4,5
TPT0780-8
b
35 min.
s
ø0,6
h
5
TPT0779-5
b
38 min.
h
5
s
ø0,6
Straight leadsKinked leads
B59***
B 10**, B 11**, B 16**, C 10**Line Card Applications, Leaded Disks
Telecom