Wide Trim powerMod Series 400W-800W Wide Trim powerMod Series PLUG & PLAY POWER next generation power solution FEAtUREs & OPtiOns * Dual safety Approvals - UL/En60950 2nd edition - UL/En60601-1 3rd edition * 1.0V to 58V standard output voltages * standard Medical Features - Leakage Current <300A (<150A optional) - 2 MOPP - 4KV isolation * Highest Efficiency - up to 92% * sEMi F47 Compliant * individual output control signals * - 40C startup temperature * Conducted EMi En 55022 Class B * OVP, OtP, OCP as standard * MiL stD-810G: shock & Vibration * Adjustable output voltages * Adjustable current limit * Output inhibit / enable control * Parallel / series of multiple outputs * All outputs fully floating * these new powerMods are all 100% interchangeable and compatible with all Excelsys Modular powerPacs & other powerMods the new Wide-trim powerMod family of plug-in DC modules from Excelsys is compatible with all powerPac families in the Excelsys range. the powerMods convert the intermediate bus voltage provided by the powerPac to your specific output DC voltage requirements. the powerPac families include UltiMod, Ultra Quiet Xgen, High Power Xgen and Hi-Rel/MiLCOts Xgen available as standalone chassis to 1340W, but each can be paralleled for operation above 2KW. The existing Excelsys powerMods provide output voltages from 1.5V to 58V. The feature rich powerMods provide a suite of output signals and user configurable functions increasing design-in flexibility. User configurable functions include local and remote adjustment, adjustable current limit, dynamic voltage trim/adjust, alternative current limiting technique and inhibit/enable functions. Existing powerMods in this range include XgA-XgL and Xg1-Xg8. Excelsys now expands this family with four new powerMods with each offering extrawide voltage trim ranges, along with the complete suite of standard control features. The new powerMods; XgM, XgN, XgP and XgQ are available with nominal voltages of 5V, 12V, 24V, and 48V respectively, each can be trimmed down to 1.0V. All powerMods can be simply plugged into a standard powerPac in the normal way, all modules are interchangeable and can be put in series or parallel ensuring that you have the most flexible power supply at your fingertips. The XgM, XgN, XgP and XgQ powerMods continue the Excelsys tradition of providing an instant, no compromise power solution for any application where a unique set of voltage and current requirements is needed. tYPiCAL APPLiCAtiOns * Medical; Clinical diagnostic equipment, Dialysis equipment, Clinical & Cosmetic Lasers, Radiological imaging, Clinical Chemistry * industrial; test and Measurement, industrial Machines, Lasers, Automation equipment, Printing, telecommunications, Audio equipment, * Hi Rel / MiLCOts; Harsh industrial Electronics, Radar powerMods MODEL Vnom set Point Adjust Range (V) Dynamic Vtrim imax Range (V) (A) Power i Limit onset (W) OVP Remote sense Power Good XgM 5.0 3.2-6.0 1.0 to 6.0 40 200 49.5 7.3 Yes Yes XgN 12.0 6.0-15.0 1.0 to 15.0 20 240 27.5 18.0 Yes Yes XgP 24.0 12.0-30.0 1.0 to 30.0(1) 10 240 14.5 34.0 Yes Yes XgQ 48.0 24.0-58.0 1.0 to 58.0(2) 6 288 7.4 64.0 Yes Yes 1 Wide Trim powerMod Series Output Connectors The output powerMods connection details are shown below. The power and signal connectors are as follows: type A: powerMods XgM, Xgn, XgP, XgQ Output signals and Power Connector Pinout J3 Voltage Adjust 8 7 Pin 2 1 J4 2 1 J3 1 2 +Sense -Sense 3 4 Vtrim Itrim 5 6 7 8 J4 -Vout +Vout +Inhibit/Enable -Inhibit/Enable +pg -pg M4 Screws Output Mating Connectors J3: Locking Molex 51110-0860; Non Locking Molex 51110-0850; Crimp Terminal: Molex p/n 50394. Or Molex 51110-0856, includes Locking Tab & Polarization Keying, J4 (Type A): M4 Screw J4 (Type B) Connector: Camden 9200/4A: Metz Connect PN ASP0450422: Or Conta-clip PN 11209.1: Or Camden Boss CTB9200/4A: Or Altech SH04-5,00 series Connection To achieve increased output voltages, simply series outputs using standard series links, paying attention to the requirements to maintain SELV levels if required in your system. Parallel Connection for powerMods To achieve increased current capacity, simply parallel outputs using the standard parallel links. Excelsys `wireless' sharing ensures that current hogging is not possible. To parallel connect outputs: 1. Switch on IShare switch to ON for powerMods XgM - XgQ 2. Connect Negative Parallel Link. 3. Adjust output voltages of powerMods to within 5mV of each other. 4. Connect Positive Parallel Link. DiP switch for Current share & inhibit/Enable for powerMods Series Links available. Part Number XS1 Parallel Links available to order. Part Number XP1 DiP switch Option powerMods can be configured to be normally ON or normally OFF by appropriate setting of the DIP switch on the powerMod. (default mode is normally ON). The powerMod will deliver output voltage when mains is applied (and the powerPac is enabled). The powerMod requires an external 5V signal (between +IN/EN and -IN/EN) to disable the output pins. This may be reversed by setting of the dip switch to the OFF position. Dip switch settings above are: Current Share: OFF Inhibit ON: Normally ON PowerPacs These powerMods can be used in conjunction with any Excelsys Modular powerPac for a variety of applications in Medical, Industrial, Communications or Military markets. notes: 1) From 1V to 4.5V XgP output ripple and transient response are load dependent. Please consult Excelsys Applications Engineering Team or support@excelsys.com for performance characterisation. 2) From 1V to 7V XgQ output ripple and transient response are load dependent. Please consult Excelsys Applications Engineering Team or support@excelsys.com for performance characterisation. 3) Refer to the UltiMod Designers Manual for additional information. 2