4-line EMC filters
Series/Type: B84144*
The following products presented in this data sheet are being withdrawn.
Ordering Code Substitute Product Date of
Withdrawal
Deadline Last
Orders
Last Shipments
B84144G0250S000 B84144B*S120,
B84144B*S121
2009-03-13 2009-06-30 2009-09-30
B84144G0500S000 B84144B*S120,
B84144B*S121
2009-03-13 2009-06-30 2009-09-30
B84144G1000S000 2009-03-13 2009-06-30 2009-09-30
Ordering Code Substitute Product Date of
Withdrawal
Deadline Last
Orders
Last Shipments
B84144G1600S000 2009-03-13 2009-06-30 2009-09-30
For further information please contact your nearest EPCOS sales office, which will also support
you in selecting a suitable substitute. The addresses of our worldwide sales network are
presented at www.epcos.com/sales.
201/06
Please read Cautions and warnings and
Important notes at the end of this document.
Power line filters for 3-phase systems
Rated voltage 440/250 V AC, 50/60 Hz
Rated current 16 to 1600 A
Alternative version
Series B84144A*R120
and B84144B*S120/S121
offer a low-cost solution.
Construction
4-line filter
Metal case
Threaded bushes at end faces for
RF-tight installation
Features
Optimized leakage current
Easy to install
Degree of protection up to 180 A: IP 201)
Space-saving design
Design complies with
EN 133200, UL 1283, CSA C22.2 No.8
UL approval
Applications
General applications for power electronics
UPS
Wind farms
For machine tools, textile and packaging machines
Terminals
Finger-safe terminal blocks for filters up to 180 A
Busbars for filters 250 to 1600 A
Marking
Marking on component:
Manufacturer’s logo, ordering code,
rated voltage, rated current,
climatic category, date code
Minimum marking on packaging:
Manufacturer’s logo, ordering code
1) To IEC 60529
B84144A*R, B84144G*S4-line filters
for converters and power electronics
301/06
Please read Cautions and warnings and
Important notes at the end of this document.
Typical circuit diagram
Technical data and measuring conditions
Rated voltage VR440/250 V AC, 50/60 Hz
Rated current IRReferred to 40 °C ambient temperature
Test voltage Vtest 1770 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/case), for 16 … 50 A
2550 V DC, 2 s (lines/case), for 80 …180 A
2121 V DC, 2 s (lines/case), for 250 … 1600 A
Overload capability (thermal) 1.5 · IR for 3 min per hour or
2.5 · IR for 30 s per hour
Leakage current Ileak At 400 V AC, 50 Hz
Climatic category (IEC 60068-1) 25/100/21 (–25 °C/+100 °C/21 days damp heat test)
Approvals UL 1283
L1
N
SSB1076-F
L2 L2’
L3’
L1’
L3
N’
PE
PE
LINE LOAD
B84144A*R, B84144G*S4-line filters
for converters and power electronics
401/06
Please read Cautions and warnings and
Important notes at the end of this document.
Characteristics and ordering codes
× = approval granted
Not for new design. Substitute B84144B*S120/S121.
VR
AC
V
IR
A
Terminal
cross section
mm2
Ileak
mA
Rtyp
mΩ
Approx.
weight
kg
Ordering code Approvals
440/250 16 4 < 3.5 10 2.2 B84144A0016R000 ×
25 10 < 3.5 6 3.7 B84144A0025R000 ×
36 10 < 3.5 3.5 3.7 B84144A0036R000 ×
50 10 < 6 1.3 4.0 B84144A0050R000 ×
80 25 < 6 0.7 9.5 B84144A0080R000 ×
120 50 < 6 0.5 10 B84144A0120R000 ×
150 50 < 6 0.35 10 B84144A0150R000 ×
180 95 < 6 0.25 13 B84144A0180R000 ×
250 Busbars < 6 0.095 32 B84144G0250S000 ×
500 < 6 0.060 53 B84144G0500S000
1000 < 6 0.030 140 B84144G1000S000
1600 < 6 0.020 185 B84144G1600S000
B84144A*R, B84144G*S4-line filters
for converters and power electronics
501/06
Please read Cautions and warnings and
Important notes at the end of this document.
Dimensional drawings
B84144A0016R000 (16 A)
B84144A0025R000, B84144A0036R000, B84144A0050R000 (25 A, 36 A, 50 A)
SSB2221-Q-E
20.5±0.5
100±0.3 38±1
30±1
163 max.
141 max.
70±0.2
5.5±0.1
86 max.
12.5±1
113 max.
LINE LOAD
81 max.
PE M6 x 22.5
L1L2L3
L3’ L2’ L1’
2
Terminal blocks 4 mm
1±0.1
4 x M5 x 6
60±0.4
55±0.4
12.5±0.4
N
N
Marking
Tightening torque 0.6 ... 0.8 Nm
SSB1078-W-E
22.5±1
30±1
1±0.1
31±0.5
6.6±0.2
80±0.2
LINE LOAD
46±1
140±0.3
166 max.
216 max.
156 max. 91 max.
NL3 L2L1
L1’L2’L3’N
2
Terminal blocks 10 mm
126 max.
PE M6 x 25
12.5±0.4 65±0.4
4 x M6 x 6
100±0.4
Marking
Tightening torque 1.5 ... 1.8 Nm
B84144A*R, B84144G*S4-line filters
for converters and power electronics
601/06
Please read Cautions and warnings and
Important notes at the end of this document.
B84144A0080R000 (80 A)
B84144A0120R000, B84144A0150R000 (120 A, 150 A)
SSB2222-Y-E
115±0.2
LINE LOAD
155±0.3
221 max.
300 max.
171 max.
PE M10 x 32
48.5±0.5
141 max.
83±1
1.0±0.1
55±1
18±1
141 max.
L1L2L3N
N L3’ L2’ L1’
2
Terminal blocks 25 mm
6.6±0.2
110±0.4
15±0.4
110±0.4
4 x M6 x 6
Marking
Tightening torque 4 ... 4.5 Nm
93.1
SSB2223-7-E
6.6±0.2
115±0.2
LINE LOAD
155±0.3
261 max.
348 max.
171 max.
PE M10 x 32
54±0.5
141 max.
87±1
55±1
N
L3 L2 L1
L1’L2’L3’
N
2
Terminal blocks 50 mm
110±0.4
18±1
4 x M6 x 6
141 max.
15±0.4 110±0.4
1.0±0.1
Marking
Tightening torque 6 ... 8 Nm
96.8
B84144A*R, B84144G*S4-line filters
for converters and power electronics
701/06
Please read Cautions and warnings and
Important notes at the end of this document.
B84144A0180R000 (180 A)
PE M10 x 35
74±0.5
141 max.
105±1
1.2±0.1
62±0.8
16±0.5
LINE LOAD
6.6±0.2
165±0.4
404 max.
301 max.
SSB1087-V-E
171 max.
155±0.3
N L3 L2 L1
2
Terminal blocks 95 mm
141 max.
110±0.4
120±0.4
10±0.4
L1’L2’L3’N
4 x M6 x 6
Marking
Tightening torque 15 ... 20 Nm
100
B84144A*R, B84144G*S4-line filters
for converters and power electronics
801/06
Please read Cautions and warnings and
Important notes at the end of this document.
B84144G0250S000 (250 A)
SSB0996-A
4 x M8 x 7
N
350+3
N
4.5±0.5
105±0.5
4
190±0.5
120
L3’
L2’/
L1’
N’
N
L1
L2/
L3 LINE
200±1
30
ø10.5
ø12
24±1
230+2
260±1
285
370±3
460±6
=
L1 L3
L2
N
Marking
110
89.5
34
=
48
PE M10 x 30
24
4 x M8 x 7
PE M10 x 30
4171
_
315
_
LOAD
B84144A*R, B84144G*S4-line filters
for converters and power electronics
901/06
Please read Cautions and warnings and
Important notes at the end of this document.
B84144G0500S000 (500 A)
SSB0997-I
4 x M8 x 7x
PE M10 x 30
N
500
N
6±0.5
60
150
210±0.5
150±0.5
6
56.5
26
101.5
134.5
280±1
30
L1 L1’
L2/ L2’/
L3 L3’
NN
30+3
250
305
280±1
ø12
ø11
15 +1
=510±3
590±3
LINE
Marking
L1 L2 L3
N
=
4 x M8 x 7
PE M10 x 30
4198
_
LOAD
B84144A*R, B84144G*S4-line filters
for converters and power electronics
10 01/06
Please read Cautions and warnings and
Important notes at the end of this document.
B84144G1000S000 (1000 A)
SSB0998-R
4 x M8 x 7x
PE M12 x 30
N N
11±0.5
360±0.8
240±0.8
8
38
78
163
211
65
262
L2’/L2/
NN
320±1
40
50+10
465
440±1
ø12
ø14
LINE
20+140
660±3
840±3
L1 L3
N
L2
=
Marking
L1
L3
L1’
L3’
400+3
650+4
=
28
4 x M8 x 7
PE M12 x 30
3290
_
LOAD
B84144A*R, B84144G*S4-line filters
for converters and power electronics
11 01/06
Please read Cautions and warnings and
Important notes at the end of this document.
B84144G1600S000 (1600 A)
SSB0999-Z
4 x M8 x 7
N N
11±0.5
360±0.8
240±0.8
262
L2’/
L2/
NN
340±1
40
50+10
465
440±1
ø12
ø14
LINE
20 +140
690±3
870±3
N
L2
211
163
78
38
L3L1
65
8
PE M12 x 30
Marking
=
680+4
L1 L1’
L3 L3’
=
400+3 28
4 x M8 x 7
PE M12 x 30
3290
_
LOAD
B84144A*R, B84144G*S4-line filters
for converters and power electronics
12 01/06
Please read Cautions and warnings and
Important notes at the end of this document.
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
Filters for 16 … 36 A Filters for 50 A
Filters for 80 A Filters for 120 and 150 A
f
SSB1677-Q
10 10
45
1010
6
10
78
Hz
0
20
40
60
80
dB
100
α
B84144A0016 ... A0036R000
f
SSB1678-Y
10 10
45 1010610
78
Hz
0
20
40
60
80
dB
100
α
B84144A0050R000
SSB1090-F
104Hz
5
10 106107108
0
20
40
60
80
dB
100
10
30
50
70
f
α
B84144A0080R000
SSB1091-N
10
4
5
10 10
6
10
7
10
8
0
20
40
60
80
dB
100
10
30
50
70
f
Hz
α
B84144A0120R000
B84144A0150R000
B84144A*R, B84144G*S4-line filters
for converters and power electronics
13 01/06
Please read Cautions and warnings and
Important notes at the end of this document.
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
Filters for 180 A Filters for 250 to 1600 A
SSB1092-W
10
4
Hz
5
10 10
6
10
7
10
8
0
20
40
60
80
dB
100
10
30
50
70
f
α
B84144A0180R000
SSB1000-K
0
20
40
60
80
dB
100
10
45
10
6
10
7
10 Hz
8
10
f
α
B84144G*S000
B84144A*R, B84144G*S4-line filters
for converters and power electronics
14 01/06
EMC filters
Cautions and warnings
Important information
Please read all safety and warning notes carefully before installing the EMC filter and putting it into
operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs
are not removed nor their legibility impaired by external influences.
Death, serious bodily injury and substantial material damage to equipment may occur if the appro-
priate safety measures are not carried out or the warnings in the text are not observed.
Using according to the terms
The EMC filters may be used only for their intended application within the specified values in low-
voltage networks in compliance with the instructions given in the data sheets and the data book.
The conditions at the place of application must comply with all specifications for the filter used.
Warnings
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such
as planning, assembly, installation, operation, repair and maintenance. They must be provided
with the corresponding documentation.
Danger of electric shock. EMC filters contain components that store an electric charge. Danger-
ous voltages can continue to exist at the filter terminals for longer than five minutes even after
the power has been switched off.
The protective earth connections shall be the first to be made when the EMC filter is installed and
the last to be disconnected. Depending on the magnitude of the leakage currents, the particular
specifications for making the protective-earth connection must be observed.
Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen-
cies that may cause resonances etc. can lead to destruction of the filter housing.
EMC filters must be prot ected in the application against impermissible excee ding of the rated
currents by suitable overcurrent protective.
15 01/06
EMC filters
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas o f a pplication. T hese statements are bas ed on o ur know ledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expres sly point out that su ch st atements can not b e reg arded as b inding
statements about the suitability of our products for a particular customer application. As
a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers t hemselves. For these reasons , it is always ultimately incum bent on t he
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic components
or failure before the end of their usual service life cannot be completely ruled out in the
current sta te of the art, even if th ey are operated as specified. I n customer appli cations
requiring a very high level of operational safety and especially in customer applications in which
the malfunction or failure of a passive electronic component could endanger human life or health
(e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of
suitable design of t he c ustomer a pplication or ot her ac tion t aken by t he cu stomer (e. g.
installation of protective circuitry or redundancy) that no injury or damage is sustained by third
parties in the event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order t o satisfy c ertain technical requirem ents, some of the products described in t his
publication may co ntain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as “hazardous”). Useful information on this will be found in our
Material Data Sheets on the I nternet (www. epcos.com/material). Should you hav e any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may ch ange from time to time. The same is t rue of the corresponding product
specifications. Please check t herefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We a lso reserve the ri ght t o discontinue p roduction a nd d elivery of p roducts.
Consequently, we cannot guarantee that all products named in this publication will always be
available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version
of the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The t rade nam es EPCOS, EPCOS-Jones, Baoke, C eraDiode, CSSP, ML SC, Phas eCap,
PhaseMod, SIFI, SIKOREL, Silver Cap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are
trademarks registered or pending in Europe and in other countries. Further information will be
found on the Internet at www.epcos.com/trademarks.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
EPCOS:
B84144A16R B84144A36R B84144G1600S B84144A25R B84144A150R B84144A50R B84144G1000S
B84144G250S B84144A120R B84144A180R B84144A80R B84144G500S B84144A0150R000