VDE TV-15, 30 AMP (1 Form A) Power Relay 50 1.969 HE RELAYS FEATURES 33 1.299 * High contact capacity with superior inrush current characteristics; 35.8 1.409 1 Form A 30 A 277 V AC TV-15 Rating TV rating 2 Form A 25 A 277 V AC TV-10 * Excellent high heat-resistance; * High dielectric strength: 10,000 V surge Conforming to VDE0806 (Insulation gap: 8 mm .315 inch) VDE, TUV also approved mm inch SPECIFICATIONS Contacts Characteristics Type Arrangement Contact material Initial contact resistance, max. (By voltage drop 6 V DC 1A) Nominal switching capacity Rating (resistive) Expected life (min. operations) Max. switching power Max. switching voltage Max. switching current Mechanical (at 180 cpm) Electrical (at 20 cpm) DC coil type AC coil type 1a 2a 1a 2a Silver alloy Maximum operating speed Initial insulation resistance*1 Between open contacts Initial Between contacts and breakdown coil voltage*2 Between contact sets (2a) Surge voltage between coil and contact*3 Operate time*4 (at nominal voltage) Release time*4 (at nominal voltage) Temperature rise, max. (resistive load)(at 55C) Functional*5 Shock resistance Destructive*6 100 m 30 A 277 V AC 8,310 VA 25 A 277 V AC 6,925 VA 30 A 277 V AC 8,310 VA 25 A 277 V AC 6,925 VA 277 V AC, 30 V DC 30 A 25 A 107 30 A 25 A 5x106 10 (1a: 30 A 277 V AC, 2a: 25 A 277 V AC) 2x105 (1a: 30 A 250 V AC, 2a: 20 A 250 V AC) 5 Coil (at 20C 68F) Nominal operating power DC coil type 1.92 W Functional*7 AC coil type See Coil data (next page) Vibration resistance Destructive Remarks Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "initial breakdown voltage" section *2 Detection current: 10 mA *3 Wave is standard shock voltage of 1.2x50s according to JEC-212-1981 *4 Excluding contact bounce time *5 Half-wave pulse of sine wave: 11ms; detection time: 10s *6 Half-wave pulse of sine wave: 6ms *7 Detection time: 10s *8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24). TYPICAL APPLICATIONS 1. Home appliances * Air conditioners * Microwave ovens * TV sets * Heaters * Stereo 2. Office equipment * Copiers * Vending machines 110 Ambient temp. Humidity DC coil type AC coil type 20 cpm Min. 1,000 M at 500 V DC 2,000 Vrms for 1 min. 5,000 Vrms for 1 min. 4,000 Vrms for 1 min. Min. 10,000 V Approx. 20 ms Approx. 5 ms Approx. 20 ms 60C 65C 98 m/s2 {10 G} 980 m/s2 {100 G} 10 to 55 Hz at double amplitude of 1 mm 10 to 55 Hz at double amplitude of 1.5 mm -50C to +55C -58F to +131F 5 to 85% R.H. Air pressure 86 to 106 kPa Approx. 90 g 3.17 oz (Plug-in type) Unit weight ORDERING INFORMATION HE 1a N S DC12 V Contact arrangement Pick-up voltage Terminals Coil voltage 1a: 1 Form A 2a: 2 Form A N: 70% of nominal voltage Nil: Plug-in terminal type S: Screw terminal type SW: Screw terminal type (wide pitch) Q: NEMA terminal type P: PC board terminal type* DC: 6, 12, 24, 48, 110 V AC: 12, 24, 48, 120, 240 V Standard packing: Carton: 20 pcs.; Case: 100 pcs. * PC board terminal are available only for 1 Form A type of DC coil voltage. UL/CSA, TUV approved type is standard. HE TYPES Terminal shape Plug-in terminal Screw terminal DC Screw terminal type (wide pitch) NEMA terminal PC board terminal Contact arrangement 1 Form A 2 Form A HE1aN-DC6V HE2aN-DC6V HE1aN-DC12V HE2aN-DC12V HE1aN-DC24V HE2aN-DC24V HE1aN-DC48V HE2aN-DC48V HE1aN-DC110V HE2aN-DC110V HE1aN-S-DC6V HE2aN-S-DC6V HE1aN-S-DC12V HE2aN-S-DC12V HE1aN-S-DC24V HE2aN-S-DC24V HE1aN-S-DC48V HE2aN-S-DC48V HE1aN-S-DC110V HE2aN-S-DC110V HE1aN-SW-DC6V HE2aN-SW-DC6V HE1aN-SW-DC12V HE2aN-SW-DC12V HE1aN-SW-DC24V HE2aN-SW-DC24V HE1aN-SW-DC48V HE2aN-SW-DC48V HE1aN-SW-DC110V HE2aN-SW-DC110V HE1aN-Q-DC6V HE2aN-Q-DC6V HE1aN-Q-DC12V HE2aN-Q-DC12V HE1aN-Q-DC24V HE2aN-Q-DC24V HE1aN-Q-DC48V HE2aN-Q-DC48V HE1aN-Q-DC110V HE2aN-Q-DC110V HE1aN-P-DC6V -- HE1aN-P-DC12V -- HE1aN-P-DC24V -- HE1aN-P-DC48V -- HE1aN-P-DC110V -- Terminal shape Plug-in terminal Screw terminal AC type Screw terminal (wide pitch) NEMA terminal Contact arrangement 1 Form A 2 Form A HE1aN-AC12V HE2aN-AC12V HE1aN-AC24V HE2aN-AC24V HE1aN-AC48V HE2aN-AC48V HE1aN-AC120V HE2aN-AC120V HE1aN-AC240V HE2aN-AC240V HE1aN-S-AC12V HE2aN-S-AC12V HE1aN-S-AC24V HE2aN-S-AC24V HE1aN-S-AC48V HE2aN-S-AC48V HE1aN-S-AC120V HE2aN-S-AC120V HE1aN-S-AC240V HE2aN-S-AC240V HE1aN-SW-AC12V HE2aN-SW-AC12V HE1aN-SW-AC24V HE2aN-SW-AC24V HE1aN-SW-AC48V HE2aN-SW-AC48V HE1aN-SW-AC120V HE2aN-SW-AC120V HE1aN-SW-AC240V HE2aN-SW-AC240V HE1aN-Q-AC12V HE2aN-Q-AC12V HE1aN-Q-AC24V HE2aN-Q-AC24V HE1aN-Q-AC48V HE2aN-Q-AC48V HE1aN-Q-AC120V HE2aN-Q-AC120V HE1aN-Q-AC240V HE2aN-Q-AC240V COIL DATA at 20C 68F DC coil type AC coil type Nominal voltage Pick-up voltage, V DC (max.) Drop-out voltage, V DC (min.) Nominal coil current, mA (10%) Coil resistance, (10%) Nominal operating power, W 6 V DC 12 V DC 24 V DC 48 V DC 110 V DC 4.2 8.4 16.8 33.6 77.0 0.6 1.2 2.4 4.8 11.0 320.9 160 80 40 17.5 18.8 75 300 1200 6300 1.92 1.92 1.92 1.92 1.92 Nominal voltage Pick-up voltage, V AC (max.) Drop-out voltage, V AC (min.) Nominal coil current, mA (10%) Coil resistance, (10%) Nominal operating power, VA 12 V AC 24 V AC 48 V AC 120 V AC 240 V AC 8.4 16.8 33.6 70.0 140.0 1.8 3.6 7.2 18.0 36.0 138* 74* 39* 22.1* 10.8* 75 300 1200 5200 20800 1.7 1.8 1.9 2.7 2.6 Max. allowable voltage (at 50C 122F), V DC 6.6 13.2 26.4 52.8 121.0 Max. allowable voltage (at 50C 122F), V AC 13.2 26.4 52.8 132.0 264.0 *Value at 60 Hz 111 HE DIMENSIONS mm inch 1. Plug-in terminal type 1a 2a 36.4 1.433 2-4.5 dia. 2-.177 dia. 2-4.5 dia. 2-.177 dia. 1 1 4 Schematic 1a 36.4 1.433 14.4 .567 2 3 0.8 .031 6.35 .250 6 5 1 2 3 4 33 1.299 R4 6 5 5 6 5 40 1.575 50 1.969 40 1.575 50 1.969 8.4 10.25 .331 .404 4 4 33 1.299 R4 6 2a 1 FASTON No. 250 FASTON No. 250 3.5 .138 Panel cutout 10.4 .409 10.4 .409 35 1.378 35 1.378 0.8 .031 0.8 .031 2-4.50.1 dia. 2-.177.004 dia. 400.1 1.575.004 General tolerance: 0.3 .012 2. NEMA terminal type 4.5 .177 1a 2a 47.6 1.874 36.4 1.433 47.6 1.874 36.4 1.433 14.4 .567 1 4.5 .177 4 1 2 Schematic 1a 3 R4 6.35 .250 R4 6 40 1.575 50 1.969 60 2.362 8.4 10.25 .331 .404 0.8 .031 33 1.299 5 4 6 5 3.5 .138 3 4 6 5 Panel cutout FASTON No. 250 10.4 .409 2 5 40 1.575 50 1.969 60 2.362 FASTON No. 250 1 4 33 1.299 6 2a 1 2-4.50.1 dia. 2-.177.004 47.60.1 1.874.004 10.4 .409 35 1.378 35 1.378 0.8 .031 0.8 .031 General tolerance: 0.3 .012 3. Screw terminal type 1a M4.5 51.0 2.008 40.0 1.575 14.4 .567 2-4.5 dia. 2-.177 M3.5 2a M4.0 11.3 .445 R4 10.25 .404 17.5 .689 2-4.5 dia. 2-.177 11.3 .445 R4 10.25 .404 16.5 .650 33.5 1.319 50.0 1.969 M3.5 7.5 .295 44.5 1.752 Schematic 1a 51.0 2.008 40.0 1.575 36.4 1.433 14.4 .567 33.5 1.319 50.0 1.969 7.5 .295 44.5 1.752 0.8 .031 General tolerance: 0.3 .012 112 4 6 5 1 2 6 16.5 .650 Panel cutout 3.5 .138 0.8 .031 17.5 .689 2a 1 2-4.50.1 dia. 2-.177.004 dia. 400.1 1.575.004 3 4 5 HE 4. Screw terminal type (wide pitch) mm inch 1a 2a 51.0 2.008 47.6 1.874 40.0 1.575 14.4 .567 M4.5 M4.0 4.5 .177 Schematic 1a 51.0 2.008 47.6 1.874 40.0 1.575 36.4 1.433 14.4 .567 4.5 .177 17.5 11.3 .689 .445 11.3 17.5 .445 .689 R4 4 6 5 1 2 3 6 4 5 R4 16.5 10.25 .650 .404 33.5 1.319 50.0 1.969 60 2.362 M3.5 2a 1 16.5 10.25 .650 .404 33.5 1.319 50.0 1.969 60 2.362 M3.5 Panel cutout 2-4.50.1 dia. 2-.177.004 7.5 .295 47.60.1 1.874.004 7.5 .295 44.5 1.752 44.5 1.752 3.5 .138 0.8 .031 0.8 .031 General tolerance: 0.3 .012 5. PC board terminal type Schematic (Bottom view) 38.0 1.496 PC board pattern (Copper-side view) 33 1.299 1 6-2 dia. 6-.079 dia. 4 32 1.259 18.6 .732 36.3 1.429 0.5 .020 4 .157 6 8.4 .331 5 24 .945 4.7 .185 4.7 .185 REFERENCE DATA 1 Form A Type 1. Maximum switching power 2. Life curve 3. Contact temperature rise (DC type) Measured portion: Inside the coil Contact current: 30 A 1,000 AC resistive 10 5 DC resistive 1 0.5 70 500 Temperature rise, C 50 30 20 No. of operations, x104 Contact current, A 100 100 250 V AC resistive 30 V DC resistive 50 10 60 20C 50 40C 40 60C 30 20 5 10 30 100 500 1,000 Contact voltage, V 0 5 10 15 20 25 30 Contact current, A 35 0 100 110 120 Coil applied voltage, %V 4. Ambient temperature characteristics Sample: HE1aN-AC120V, 6 pcs. Rate of change, % 30 -50 -20 0 20 Pick-up voltage x-x 10 Drop-out voltage 20 40 -10 60 80 Ambient temperature, C -20 -30 113 HE 2 Form A Type 1. Maximum switching power 2. Life curve 3. Contact temperature rise (DC type) 1,000 50 30 20 500 AC resistive 10 DC resistive 5 70 60 Temperature rise, C 100 No. of operations, x104 Contact current, A Measured portion: Inside the coil Contact current: 30 A 100 250 V AC resistive 30 V DC resistive 50 1 10 0.5 5 20C 50 40C 60C 40 30 20 10 30 100 500 1,000 Contact voltage, V 0 5 10 15 20 25 30 Contact current, A 35 0 100 110 120 Coil applied voltage, %V 4. Ambient temperature characteristics Rate of change, % Sample: HE2aN-AC120V, 6 pcs. Pick-up 20 voltage xx- 10 Drop-out voltage -50 -20 0 20 40 -10 60 80 Ambient temperature, C -20 -30 MOUNTING METHOD 1. Plug-in terminal type 2. Screw terminal type M 4 screw M4 screw Washer Faston No.250 Washer 3. Allowable installation wiring size for screw terminal types and terminal blocks 1a type 2a type 2.6 mm or 5.5 mm2 2.0 mm or 3.5 mm2 Due to the UP terminals, it is possible to either directly connect the wires or use crimped terminal NOTES 1. The dust cover should not be removed since doing so may alter the characteristics. 2. Avoid use under severe environmental conditions, such as high humidity, organic gas or in dust, oily locations and locations subjected to extremely frequent shock or vibrations. 3. When mounting, use spring washers. Optimum fastening torque ranges from 5 kg to 7 kg*cm 4.5 to 6 pounds*inch. 4. Firmly insert the receptacles so that there is no slack or looseness. To remove a receptacle, 2 to 4 kg of pulling strength is required. Do not remove more than one receptacle at one time.Always remove one receptacle at a time and pull it straight outwards. 5. Install the relay so that it lies in direction A (up-down direction). (Pick-up voltage and drop-out voltage values are those when installed in direction A.) 6. When using the AC type, the operate time due to the in-rush phase is 20 ms or more. Therefore, it is necessary for you to verify the characteristics for your actual circuit. Moreover, the release time for the NC side of the 2a1b type requires the same verification. 7. When using the push-on blocks for the screw terminal type, use crimped terminals and tighten the screw-down terminals to the torque's listed below. M4.5 screw M4 screw M3.5 screw 147 N-cm to 166.6 N-cm (15 to 17 kg*cm) 117.6 N-cm to 137 N-cm (12 to 14 kg*cm) 78.4 N-m to 98 N-cm (8 to 10 kg*cm) 8. All AC240V types are rated for double coil voltage, both AC 220V AC 240V. For Cautions for Use, see Relay Technical Information (Page 11 to 39). 114 HE HE RELAY ACCESSORIES TYPES Terminal socket instantly attachable to DIN rail Part No. JH1-SF JH2-SF Applicable relays HE1a/JH1a HE2a/JH2a SPECIFICATIONS Part No. Maximum continuous current* Breakdown voltage Insulation resistance Heat resistance JH1, JH2 20 A 250 V AC (1a: 30 A 250 V AC) 2,000 Vrms between terminals More than 1,000 M between poles 150C 3C for 1 hour * Don't insert or remove relays while in the energized condition. DIMENSIONS mm inch 1 Form A, 2 Form A Relay mounting diagram 6 9 .354 8 1 2 22 60 .866 2.362 9 .354 Panel cutout 7 3 5 4 10.25 .404 4 .157 11 .433 14.4 .567 11 .433 8.4 .331 40 1.575 9.2 .362 16 .630 23 .906 61 2.402 2-DIA. 4.2 2-DIA. .165 (2-M4 Screw hole) (2-M.157 Screw hole) 34 1.339 70 2.756 MOUNTING METHOD 1. Relay mounting 2. Installing to a DIN rain 3. Removing from a DIN rain Push Flat-head screw driver NOTE 1. Be careful not to drop the relay. It is made of heat-hardened resin and may break. 12/27/2002 2. Be sure to tighten the screw- down terminals firmly. Loose terminals may lead to the generation of heat. All Rights Reserved, (c) Copyright Matsushita Electric Works, 115 Ltd. Go To Online Catalog