Agilent U1610A/U1620A Handheld Digital Oscilloscope Data Sheet Features * 5.7-inch VGA TFT LCD display with 3 selectable viewing modes (indoor, outdoor and night vision) * 2 Mpts memory depth and 2 GSa/s sampling rate allows detailed analysis of captured glitches * 100/200 MHz bandwidth with two isolated channels * 10,000-count resolution on DMM display * Channel-to-channel isolation with CAT III 600 V safety ratings * Data logging capability to PC Retool your expectations in the world's first handheld scope with three viewing modes on a VGA TFT LCD display Agilent's U1610A/U1620A oscilloscope takes troubleshooting and maintenance task to a whole new level by being the world's first handheld scope with three viewing modes on a VGA TFT LCD display. Whether you're working in a poorly lit environment, or under the glaring sun, the revolutionary display ensures that you can analyze waveforms effortlessly under all lighting conditions by 3 selectable viewing modes (indoor, outdoor and night vision mode). Coupled with 2 Mpts memory depth, it enables you to capture long, non-repeating signals with excellent zooming capabilities onto selective glitches. Further complementing your viewing experience is the 5.7 inch screen that allows signal overviews to be analyzed on a wider viewing area. 5.7-inch VGA display with 3 selectable viewing modes Visualizing electrical waveforms has never been in such clarity. Our U1610A/U1620A oscilloscope comes with a 5.7-inch VGA TFT LCD display that enables clear viewing of measurements on-site and on the field. With the option of up to three viewing modes, users can now view waveforms under all lighting conditions, including in indoor, outdoor or dark environments. All three viewing modes have predefined contrast levels for customized lighting conditions and optimized battery life. Indoor mode Outdoor mode Night vision mode The indoor mode has high contrast and brightness levels to clearly distinguish waveforms under an indoor light environment. Engineered with a VGA TFT LCD screen, users can now view the display across wide viewing angles for more efficient troubleshooting task. When performing field work in an outdoor environment, users can easily switch to this viewing mode via a set of accessible soft keys. This mode works in an anti-glare mechanism; it filters out excessive sunlight, hence reducing the risk of misreading or misinterpreting measurements. The night vision mode is tailored to be viewable under subdued lighting by enabling high contrast levels between the screen background and waveforms. With a single press of button, this mode is activated and the screen automatically adjusts with proper colour correction-creating clear contrasts between the waveforms against the dark environment. This mode is useful when measuring high speed signals, particularly in non-repetitive signals. Figure 1. Indoor mode for clear distinct readings Figure 2. Outdoor mode that is sunlight viewable Figure 3. Night vision mode for performing tasks in a poorly lit environment 2 Mpts memory depth and 2 GSa/s sampling rate allows detailed analysis of captured glitches A good oscilloscope must be accompanied with even better specifications for an in-depth analysis of captured glitches. With deep memory of 2 Mpts and sampling rate of 2 GSa/s, non-repeating signals can be captured over a wider time base. What's more, its dual window zoom feature allows you to work more productively by simultaneously viewing signals captured over a period of time and zooming into the most subtle details. Channel-to-channel isolation with CAT III 600 V safety ratings The U1610/U1620A extends the maximum input rating to cater for high voltage measurement and transient voltages which are recordable via a handheld oscilloscope. Equipped with the most robust isolation topology, technicians can now measure signals in the field and perform floating measurements. This type of isolation enables each channel to be individually isolated from one another and from other non-isolated system components. 2 Front panel description 5.7- inch VGA color display Function softkeys To perform functions displayed above each softkey Scope terminals USB interface connector and DC power inlet Acquisition and function controls To access the scope, meter, logger, system functions Directional keys Horizontal controls To control the sweep speed (sec/div) and horizontal position of the waveform. Use Menu/Zoom to zoom into waveforms Measurement softkeys To make quick measurements and place cursors on the waveform Vertical controls To set the vertical scaling (volt/div) and vertical offset Power on/off button Meter terminals Figure 4. The U1620A as shown 3 Specifications U1610A Specification U1620A Vertical system Bandwidth (-3 dB) 1 100 MHz 200 MHz DC vertical gain accuracy 1 4% of full scale Full scale is equivalent to 8 div Dual cursor accuracy 1 {DC vertical gain accuracy + 0.4% full scale (~1 least significant bit (LSB)} {4% full scale 0.4% full scale (~1 LSB)} Characteristic Acquisition Maximum sample rate Maximum waveform memory depth 1 GSa/s interleaved, 500 MSa/s per channel 2 GSa/s interleaved, 1 GSa/s per channel 120 Kpts/channel (interleave), 60 Kpts/channel (non-interleave) 2 Mpts/channel (interleave), 1 Mpts/channel (non-interleave) Vertical resolution 8 bits Peak detection > 10 ns Average Selectable from 2 to 8192 in powers-of-2 increments Filter > 5 ns 10 kHz and 20 MHz bandwidth limiters Interpolation (Sin x)/x Vertical system Analog channels Calculated rise time Channel 1 and Channel 2 simultaneous acquisition 3.50 ns typical Vertical scale 1.75 ns typical 2 mV/div to 50 V/div Maximum input CAT III 600 V (with 10:1 probe) CAT III 300 V (direct) Offset (position) range 4 div Dynamic range 8 div Input impedance 1 M 1% 22 pF 3 Pf Coupling DC, AC Bandwidth limit 10 kHz and 20 MHz (selectable) Channel-to-channel isolation (with channels at the same V/div) CAT III 600 V Probes U1560-60002 1:1 passive probe U1561-60002 10:1 passive probe U1562-60002 100:1 passive probe Probe attenuation factors 1x, 10x, 100x Probe compensation output Noise peak-to-peak (typical) DC vertical offset (position) accuracy Single cursor accuracy 5 Vpp, 1 kHz 3% of full scale or 5 mVpp, whichever greater 0.1 div 2 mV 1.6% offset value {DC vertical gain accuracy + DC vertical offset accuracy + 0.2% full scale (~1/2 least significant bit (LSB)} {4% full scale 0.1 div 2 mV 1.6% offset value + 0.2% full scale (~1/2 LSB)} 4 Specifications (continued) U1610A U1620A Range 5 ns/div to 50 s/div 2 ns/div to 50 s/div Resolution 100 ps for 5 ns/div 40 ps for 2 ns/div Characteristic (continued) Horizontal system Timebase accuracy 25 ppm Reference position Delay range (pre-trigger) Delay range (post-trigger) Delay resolution Delay time measurement accuracy Left, center, right 1 screen width or 120 s (whichever less) 1 screen width or 1 ms (whichever less) 50 ms to 500 s 20 ms to 500 s 100 ps for 5 ns/div 40 ps for 2 ns/div Same channel: 0.0025% reading 0.17% screen width 60 ps Channel-to-channel: 0.0025% reading 0.17% screen width 120 ps Modes Main, zoom, XY, roll Horizontal pan and zoom Dual window zoom Trigger system Sources Channel 1, Channel 2, External Modes Normal, Single, Auto Types Edge, Glitch, TV, Nth Edge, CAN, LIN Autoscale Holdoff time Finds or displays active channels, sets the edge trigger type on the highest numbered channel, and sets the vertical sensitivity on the scope channel timebase to display ~2 periods Requires > 10 mVpp minimum voltage, 0.5% duty cycle, and > 50 Hz minimum frequency 60 ns to 10 s Range 6 div from center of screen Sensitivity 10 mV/div: 0.5 div < 10 mV/div: greater of 1 div or 5 mV Trigger level accuracy Coupling modes 0.6 div AC (~10 Hz), DC, LF-Reject (~35 kHz), HF-Reject (~35 kHz) External trigger * Input impedance 1 M 10 pF * Maximum input CAT III 300 V * Range DC coupling: trigger level 5 V * Bandwidth 100 kHz Measurement Automatic measurements Delay, duty cycle (+/-), fall/rise time, frequency, period, phase shift, T-max, T-min, width (+/-), amplitude, average, base, crest, cycle mean, maximum, minimum, overshoot, peak-to-peak, preshoot, standard deviation, top, Vrms (AC/DC), active/apparent/reactive power, power factor Waveform math functions CH1 + CH2, CH1 - CH2, CH2 - CH1, CH1 x CH2, CH1/CH2, CH2/CH1, d/dt (CH1), d/dt (CH2), (CH1)dt, (CH2)dt, FFT Cursors Delta V: Voltage difference between cursors Delta T: Time difference between cursors FFT points FFT windows 1024 Rectangular, Hamming, Hanning, Blackman-Harris, Flattop 5 Specifications (continued) Characteristic (continued) U1610A U1620A Display system Display Resolution Control 5.7" TFT LCD VGA Color (outdoor readable) VGA (screen area): 640 vertical by 480 horizontal Vectors on/off, sin x/x interpolation on/off, infinite persistence on/off, backlight intensity, color scheme, clear display Real-time clock Date and time (adjustable) Language Built-in help system 10 languages (selectable) Functional quick help displayed by pressing the [Help] button Storage system Save/recall (non-volatile) 10 setups and waveforms can be saved and recalled internally Storage mode USB 2.0 full speed host port Image formats: .bmp (8-bit, 24-bit) and .png (24-bit) Data format: .csv I/O USB 2.0 full-speed host, USB 2.0 full-speed client Printer compatibility 2 PCL Inkjet, PCL Laser 1. Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and within 23 10 C of last calibration temperature. 2. For a list of compatible printers, visit www.agilent.com/find/handheldscope-printers. 6 Digital multimeter specifications * Accuracy is given as (% of reading + counts of least significant digit) at 23 C 5 C, with relative humidity < 80 RH. * AC V specifications are AC coupled, true RMS and are valid from 5% to 100% of range. Maximum reading Voltage Function DCV ACV ACV + DCV Diode 3 10,000 counts with automatic polarity indication CAT II 1000 V or CAT III 600 V Range Resolution Accuracy 1000.0 mV 0.1 mV 0.09% + 5 10.000 V 0.001 V 100.00 V 0.01 V 1000.0 V 2 0.1 V 1000.0 mV 0.1 mV 10.000 V 100.00 V 0.001 V 0.01V 1000.0 V 2 0.1 V 1000.0 mV 0.1 mV 10.000 V 100.00 V 0.001 V 0.01 V 1000.00 V 2 0.1 V 1V 0.001 V Input impedance Test current (nominal) 0.09% + 2 0.15% + 5 11.11 M 10.10 M 10.01 M 1% + 5 (40 to 500 Hz) 2% + 5 (500 Hz to 1 kHz) 1% + 5 (40 to 500 Hz) 1% + 5 (500 Hz to 1 kHz) 10.00 M 2% + 5 (1 to 2 kHz) 1% + 5 (40 to 500 Hz) 1% + 5 (500 Hz to 1 kHz) 1.1% + 10 (40 to 500 Hz) 2.1% + 10 (500 Hz to 1 kHz) 1.1% + 7 (40 to 500 Hz) 1.1% + 7 (500 Hz to 1 kHz) 10.00 M 2% + 5 (1 to 2 kHz) 1.2% + 10 (40 to 500 Hz) 1.2% + 10 (500 Hz to 1 kHz) 0.3% + 2 ~0.5 mA Beeper < ~50 mV, Single tone for normal forward-biased diode or semiconductor junction of 0.3 V reading 0.8 V 8 Instant continuity 3 Resistance Capacitance Continuous beep when resistance < 10 8 1000.00 4 0.1 10.000 k 4 0.001 k 100.00 k 0.01 k 1000.0 k 0.1 k 0.5 mA 0.3% + 3 50 A 4.91 A 447 nA 10.000 M 0.001 M 0.8% + 3 112 nA 100.00 M 5 0.01 M 1.5% + 3 112 nA 1000.0 nF 0.1 nF 10.000 F 0.001 F 100.00 F 0.01 F 1000.0 F 0.1 F 10.000 mF 0.001 mF 1.2% + 4 6 2% + 4 6 7 Digital multimeter specifications (continued) Maximum reading Voltage 10,000 counts with automatic polarity indication CAT II 1000 V or CAT III 600 V Function Range Resolution Accuracy Temperature 3 -50 to 1000 C -58 to 1832 F Frequency 3 100.00 Hz 1 mV/C 1 mV/F -50 to -21 C 2.5% + 2 C 7 -20 to 350 C 0.5% + 2 C 7 351 to 500 C 1.75% + 2 C 7 501 to 1000 C 2% + 2 C 7 -58 to -5.8 F 2.5% + 3.6 F 7 -4 to 662 F 0.5% + 3.6 F 7 664 to 932 F 1.75% + 3.6 F 7 933 to 1832 F 2% + 3.6 F 7 Input impedance (nominal) 0.01 Hz 1000.0 Hz 0.1 Hz 10.000 kHz 0.001 kHz 100.00 kHz 0.01 kHz 1000.0 kHz 0.1 kHz 0.03% + 3 1. Only allowed to measure up to CAT III 600 V if referring to GND. 2. Only allowed for floating voltage. 3. Denotes typical specifications, all others are warranted. 4. The accuracy is specified after the Null function is used to subtract the test lead resistance and thermal effect. 5. RH is specified for < 60%. The temperature coefficient is 0.15 x specified accuracy as > 50 M. 6. The accuracy is based on film capacitors or better and uses the Relative mode for residual values. 7. The accuracy is based on using the Null function to reduce the thermal effect. 8. Denotes characteristics. 8 Test current General specifications Power supply Power adapter Line voltage range: 50/60 Hz, 100 to 240 VAC, 1.6 A Output voltage: 15 VDC, 4 A Installation Category II Battery Li-Ion rechargeable battery pack, 10.8 V Operating time: Up to 3 hours Operating environment Temperature 0 to 50 C (with battery only) 0 to 40 C (with power adapter) Humidity 0 to 80% RH (0 to 35 C) 0 to 50% RH (35 to 40/50 C) Altitude up to 2000 m Pollution degree 2 Storage compliance Temperature -20 to 70 C Humidity 0 to 80% RH Altitude up to 15000 m Shock Tested to IEC 60068-2-27 Vibration Tested to IEC 60068-2-6, IEC 60068-2-64 Safety compliance IEC 61010-1:2001/EN 61010-1:2001 Canada: CAN/CSA-C22.2 No. 61010-1-04 USA: ANSI/UL 61010-1:2004 EMC compliance IEC 61326-1:2005/EN 61326-1:2006 Australia/New Zealand: AS/NZS CISPR 11:2004 Canada: ICES/NMB-001:ISSUE 4, June 2006 IP rating IP 41 ingress protection according to IEC 60529 Dimensions (W x H x D) 183 x 270 x 65 mm Weight < 2.5 kg Warranty 3 years for main unit 3 months for standard shipped accessories unless otherwise stated 9 Ordering information Standard shipped items * Quick start guide, power adapter, Li-Ion battery pack, USB cable, test lead, 10:1 probe (2 sets). Recommended accessories Item Description U1560B Scope probe x1 CAT III 300 V * Include ground alligator clip and hook clip, rated CAT III 300 V U1562B Scope probe x100 CAT III 600 V * Include ground alligator clip and hook clip, rated CAT III 600 V U1572A Li Polymer battery pack * 4,800 mAh, 10.8 * Compatible with U1610A/20A handheld oscilloscope U1573A Desktop charger & Li Polymer battery pack * 4,800 mAh, 10.8 V * Compatible with U1610A/20A handheld oscilloscope U1575A Desktop charger * 2-output 3 A battery charger * Dimensions: 6.89 x 4.89 x 2.30 inches U1591A Soft carrying case * Soft carrying case with backpack and shoulder strap 10 www.agilent.com www.agilent.com/find/handheldscope For more information on Agilent Technologies' products, applications or services, please contact your local Agilent office. The complete list is available at: Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.axiestandard.org AdvancedTCA(R) Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Agilent is a founding member of the AXIe consortium. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based highperformance measurement and automation system. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent's measurement expertise and product breadth, combined with channel partner convenience. Agilent Advantage Services is committed to your success throughout your equipment's lifetime. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair and reduce your cost of ownership. You can also use Infoline Web Services to manage equipment and services more effectively. By sharing our measurement and service expertise, we help you create the products that change our world. www.agilent.com/find/advantageservices www.agilent.com/quality www.agilent.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 (11) 4197 3500 01800 5064 800 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 375 8100 Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* Germany Ireland Israel Italy Netherlands Spain Sweden United Kingdom *0.125 /minute 49 (0) 7031 464 6333 1890 924 204 972-3-9288-504/544 39 02 92 60 8484 31 (0) 20 547 2111 34 (91) 631 3300 0200-88 22 55 44 (0) 131 452 0200 For other unlisted countries: www.agilent.com/find/contactus Revised: June 8, 2011 Product specifications and descriptions in this document subject to change without notice. (c) Agilent Technologies, Inc. 2011 Published in USA, December 5, 2011 5990-9523EN