19 mm Series
Low Cost, Stainless Steel,
Isolated Pressure Sensors
DESCRIPTION
Honeywell’s stainless steel 19C, 19U, and 19 Vacuum Gage
Series sensors were developed for pressure applications that
involve measurement of hostile media in harsh environments
compatible with 316 stainless steel. The special Vacuum Gage
Series sensors are specifically designed for applications that
can be exposed to vacuum.
The 19C Series are calibrated and temperature compensated.
They are available for use with either a constant voltage or
current source.
They feature a variety of pressure connections to allow use in
a wide range of OEM (Original Equipment Manufacturer)
equipment. The 19U Series is uncompensated for applications
that use their own specialized circuit designs.
The 19C and 19U Series sensors are rugged and reliable
transducers for use in a wide variety of pressure sensing
applications where corrosive liquids or gases are monitored.
FEATURES
Low cost
Rugged, isolated stainless steel package
Small size
Reliable semiconductor technology
Calibrated and temperature compensated
Absolute and gage pressures
Vacuum compatible, isolated sensors
0 psi to 3 psi to, 0 psi to 500 psi
POTENTIAL APPLICATIONS
Industrial controls
Process control systems
Industrial automation and flow control
Pressure calibrators
19 mm Series
2 www.honeywell.com/sensing
PRESSURE SENSOR CHARACTERISTICS (All Devices)
Environmental Specifications
Compensated temperature range 0 °C to 82 °C [32 °F to 180 °F]
Operating temperature range -40 °C to 125 °C [-40 °F to 257 °F]
Storage temperature range -40 °C to 125 °C [-40 °F to 257 °F]
Vibration 10 G at 20 Hz to 2000 Hz
Shock 100 G for 11 ms
Life 1 million cycles min.
Insulation resistance 100 mΩ at 50 Vdc
Maximum Ratings
Voltage version “K” supply voltage VS = +15 Vdc
Voltage version “L” supply current IS = +2.0 mA
PRESSURE RANGE SPECIFICATIONS (19C, 19U)
Catalog Listing Pressure Range Proof Pressure (7) Burst Pressure
(8)
19(C,U) 003P G (1…9) (K/L) 0 psig to 3 psig 9 psig 15 psig
19(C,U) 005P G (1…9) (K/L) 0 psig to 5 psig 15 psig 25 psig
19(C,U) 010P G (1…9) (K/L) 0 psig to 10 psig 30 psig 50 psig
19(C,U) 015P (A,G,V) (1…9) (K/L) 0 psi to 15 psi 45 psi 75 psi
19(C,U) 030P (A,G,V) (1…9) (K/L) 0 psi to 30 psi 90 psi 150 psi
19(C,U) 050P (A,G,V) (1…9) (K/L) 0 psi to 50 psi 150 psi 250 psi
19(C,U) 100P (A,G,V) (1…9) (K/L) 0 psi to 100 psi 300 psi 500 psi
19(C,U) 200P (A,G,V) (1…9) (K/L) 0 psi to 200 psi 600 psi 1000 psi
19(C,U) 300P (A,G,V) (1…9) (K/L) 0 psi to 300 psi 900 psi 1500 psi
19(C,U) 500P (A,G,V) (1…9) (K/L) 0 psi to 500 psi 1200 psi 2400 psi
19C SERIES PERFORMANCE CHARACTERISTICS (1)
Characteristic Minimum Typical Maximum Unit
Zero pressure offset -2 0 2 mV
Full-scale span (2) 98 100 102 mV
Full-scale span (3 psi and 5 psi “K” units only) (2) 48 50 52 mV
Pressure non-linearity (3)±0.1 ±0.25 %FSS
Pressure hysteresis (3)±0.015 ±0.030 %FSS
Repeatability – ±0.010 ±0.030 %FSS
Temp. effect on span (4)±0.5 ±1.0 %FSS
Temp. effect on offset (4)±0.5 ±1.0 %FSS
Temp. effect on span (0 psi to 3 psi and 0 psi to 5 psi only) (4) ±2.0 %FSS
Temp. effect on offset (0 psi to 3 psi and 0 psi to 5 psi only) (4) ±2.0 %FSS
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F]) ±0.1 ±0.3 %FSS
Long-term stability of offset and span (5)±0.1 ±0.3 %FSS
Response time (6)0.1 ms
Common mode voltage (voltage version “K”) (9) 0.5 1.3 2.0 Vdc
Input impedance (current version “L”) 2.0 4.5 8.0 kΩ
Input impedance (voltage version “K”) 8.0 25 50 kΩ
Output resistance 3.0 4.5 6.0 kΩ
Low Cost, Stainless Steel, Pressure Sensors
Honeywell Sensing and Control 3
19U SERIES PERFORMANCE CHARACTERISTICS (1)
Characteristic Minimum Typical Maximum Unit
Zero pressure offset -7.5 1.0 7.5 mV/V
Full-scale span (2) 30 40 60 mV/V
Full-scale span (3 psi and 5 psi only) (2) 20 30 40 mV/V
Pressure non-linearity (3)±0.1 ±0.25 %FSS
Pressure hysteresis (3)±0.015 ±0.030 %FSS
Repeatability – ±0.010 ±0.030 %FSS
Temp. coefficient of resistance (10) (0 °C to 82 °C [32 °F to 180 °F]) 2700 3420 4500 ppm/°C
Temp. coefficient of offset (10) (0 °C to 82 °C [32 °F to 180 °F]) 30 μV/V/°C
Temp. coefficient of span (10) (0 °C to 82 °C [32 °F to 180 °F]) 360 720 1620 ppm/°C
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F]) ±0.1 ±0.3 %FSS
Long-term stability of offset and span (5)±0.1 ±0.3 %FSS
Response time (6)±0.1 ms
Input resistance 4.00 4.75 6.0 kΩ
Output resistance 4.00 4.75 6.0 kΩ
19C VACUUM GAGE COMPENSATED SERIES PERFORMANCE CHARACTERISTICS (1)
Characteristic Minimum Typical Maximum Unit
Zero pressure offset (at 0 psig) -2 0 2 mV
Full-scale span (2) (0 psig to positive full-scale) 98 100 102 mV
Pressure non-linearity (3)±0.1 ±0.25 %FSS
Pressure hysteresis (3)±0.015 ±0.030 %FSS
Repeatability – ±0.010 ±0.030 %FSS
Temp. effect on span (4)±0.5 ±1.0 %FSS
Temp. effect on offset (4)±0.5 ±1.0 %FSS
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F]) ±0.1 ±0.3 %FSS
Long-term stability of offset and span (5)±0.1 ±0.3 %FSS
Response time (6)0.1 ms
Common mode voltage (voltage version “K”) (9) 0.5 1.3 2.0 Vdc
Input impedance (current version “L”) 1.5 4.5 8.0 kΩ
Input impedance (voltage version “K”) 8.0 25 50 kΩ
Output resistance 3.0 4.5 6.0 kΩ
19U VACUUM GAGE UNCOMPENSATED SERIES PERFORMANCE CHARACTERISTICS (1)
Characteristic Minimum Typical Maximum Unit
Zero pressure offset -7.5 1.0 7.5 mV/V
Full-scale span (2) (0 psig to positive full-scale) 30 40 60 mV/V
Pressure non-linearity (3)±0.1 ±0.25 %FSS
Pressure hysteresis (3)±0.015 ±0.030 %FSS
Repeatability – ±0.010 ±0.030 %FSS
Temp. coefficient of resistance (10) (0 °C to 82 °C [32 °F to 180 °F]) 2700 3420 4500 ppm/°C
Temp. coefficient of offset (10) (0 °C to 82 °C [32 °F to 180 °F]) 30 •V/V/°CV/V/°C
Temp. coefficient of span (10) (0 °C to 82 °C [32 °F to 180 °F]) 360 720 1620 ppm/°C
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F]) ±0.1 ±0.3 %FSS
Long-term stability of offset and span (5)±0.1 ±0.3 %FSS
Response time (6)±0.1 ms
Input resistance 4.00 4.75 6.0 kΩ
Output resistance 4.00 4.75 6.0 kΩ
19 mm Series
4 Honeywell Sensing and Control
Notes:
1. Reference conditions (unless otherwise noted): TA = 25 °C [77 °F]; 19C Supply VS = 10 Vdc ±0.01 Vdc or
IS = 1.5 mA ±0.0015 mA; 19U Supply VS = 5 Vdc ±0.01 Vdc or I = 1.0 mA ±0.0015 mA.
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero
pressure. FSS is ratiometric to supply voltage.
3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the
maximum output difference at any point within the operation pressure range for increasing and decreasing pressure.
4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 °C [77 °F]
reading.
5. Long-term stability over a six-month period.
6. Response time for a 0 psi to FSS pressure step change, 10% to 90% rise time.
7. The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
8. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer
9. Common mode voltage as measured from output to ground. For higher levels of common mode voltage, contact factory.
10. The error band resulting from a maximum deviation of a transducer’s output parameter (offset, span, or resistance) as
temperature is varied 25 °C [77 °F] to any other temperature within the specified range (0 °C to 82 °C [32 °F to 180 °F]). This
parameter is not 100% tested and is guaranteed by process design and tested on a sample basis only. Temperature
coefficient of span is evaluated using a 1 mA constant current excitation source.
PHYSICAL DIMENSIONS (For reference only: mm [in].)
Package 1 (see note): Cell Package
Note: Non-concentricity effects at the diaphragm weld area may cause runout of up to ±0.006 in between the upper and lower portions of the
sensor body. (It is recommended to use a counter bore to mate with this device to allow for this non-concentricity).
Package 2: Flush Mount Package
Package 3: Flush Mount with Flange
Low Cost, Stainless Steel, Pressure Sensors
Honeywell Sensing and Control 5
Package 4: Male 1/8-27 NPT
Package 5: Male 1/4-18 NPT
19 mm Series
6 Honeywell Sensing and Control
Package 6: Male 7/16 UNF
Package 7: Male 1/4 BSPP
Package 8: Euro Ring (See note)
Note: Non-concentricity effects at the diaphragm weld area may cause runout of up to ±0.006 in between the upper and lower
portions of the sensor body. (It is recommended to use a counter bore to mate with this device to allow for this non-concentricity).
Low Cost, Stainless Steel, Pressure Sensors
Honeywell Sensing and Control 7
Package 9: VCR Gland (Female nut)
ORDERING INFORMATION
Sensing and Control
Honeywell
1985 Douglas Drive North
Minneapolis, MN 55422
www.honeywell.com/sensing
009132-3-EN IL50 GLO Printed in USA
February 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales