Bel Power Solutions MAP110 Series of power supplies combines low
cost and universal input in a board-only power solution to meet
commercial and industrial requirements. Full international safety, EMI,
and ESD compliance ensure worldwide acceptance. All units bear the
CE Mark.
Wide dynamic output current and fixed-frequency operation simplifies
system level operation. The MAP110 series is configured to an
international standard footprint. Input and output connections are
made via popular single-row Molex connectors.
Single output models feature wide-range output adjustability to meet
a wide variety of standard and user-specific output voltage
requirements.
RoHS Lead-Solder-Exemption Compliant
New 5 V Output Models
Universal Input 85-264 VAC
Industry-Standard Footprint:
7.0" x 4.3" x 1.97" (177.8 x 109.2 x 50.0 mm)
Input Transient & ESD Compliance to EN61000-4-2/-3/-4
Remote sense and overvoltage protection on single output units and
main output of multiple output units
Options include Over temperature protection, Power Fail signal,
Chassis & Cover
Greater than 134,000 hours MTBF
2
MAP110 Series
tech.support@psbel.com
MODEL 7
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT
FORCED AIR
OUTPUT
CURRENT 1
LINE
REGULATION
LOAD
REGULATION
RIPPLE
&
NOISE 2
INITIAL SETTING
ACCURACY
MAP110-1005*
5V
4.95V to 5.5V
16A
22A
0.2%
1%
1%
5.09V to 5.11V
MAP110-1012G
12V
11.25V to 12.75V
7.5A
10A
0.1%
0.5%
1%
11.97V to 12.02V
MAP110-1024G
24V/28V
22.8V to 29.2V
3.8/3.2A 3
5/4.3A 3
0.1%
0.5%
1%
23.95V to 24.05V
MODEL 7
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT 4
FORCED AIR
OUTPUT
CURRENT 4
LINE
REGULATION
LOAD
REGULATION
RIPPLE
&
NOISE2
INITIAL SETTING
ACCURACY
MAP110-4000G
+5V
4.75V to 5.25V
12A/20A PK
12A/20A PK
0.2%
0.5%
1%
5.09V to 5.11V
+12V
Fixed
5A/9A PK
5A/9A PK
0.2%
1%
1%
11.97V to 12.03V
-12V
Fixed
1A/1.5A PK
1A/1.5A PK
0.2%
1%
1%
-11.4V to -12.6V
-5V
Fixed
1A/1.5A PK
1A/1.5A PK
0.2%
1.5%
1%
-4.75V to -5.25V
MAP110-4001*
+5V
4.75V to 5.25V
12A/20A PK
12A/20A PK
0.2%
0.5%
1%
5.09V to 5.11V
+24V
Fixed
3A/4.5A PK
3A/4.5A PK
0.1%
1%
1%
23.94V to 24.06V
-12V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
1%
-11.4V to -12.6V
+12V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
1%
11.4V to 12.6V
MAP110-4002G
+5V
4.75V to 5.25V
12A/20A PK
12A/20A PK
0.2%
0.5%
1%
5.09V to 5.11V
+12V
Fixed
5A/9A PK
5A/9A PK
0.1%
1%
1%
11.97V to 12.03V
-12V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
1%
-11.4V to -12.6V
+12V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
1%
11.4V to 12.6V
MAP110-4003*
+5V
4.75V to 5.25V
12A/20A PK
12A/20A PK
0.2%
0.5%
1%
5.09V to 5.11V
+15V
Fixed
5A/7.3A PK
5A/7.3A PK
0.1%
1%
1%
14.96V to 15.04V
-15V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
1%
-14.3V to -15.7V
-5V
Fixed
1A/1.5A PK
1A/1.5A PK
0.2%
1.5%
1%
-4.75V to -5.25V
MAP110-4004G
+5V
4.75V to 5.25V
12A/20A PK
12A/20A PK
0.2%
0.5%
1%
5.09V to 5.11V
+24V
Fixed
3A/4.5A PK
3A/4.5A PK
0.1%
1%
1%
23.94V to 24.06V
-15V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
1%
-14.3V to -15.7V
+15V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
1%
14.3V to 15.7V
MAP110-4010*
+5V
4.75V to 5.25V
12A/20A PK
12A/20A PK
0.2%
0.5%
1%
5.09V to 5.11V
+12V
Fixed
5A/9A PK
5A/9A PK
0.1%
2%
1%
11.97V to 12.03V
-5V
Fixed
1A/1.5A PK
1A/1.5A PK
0.2%
1.5%
1%
-4.75V to -5.25V
-12V
Fixed
3A/4A PK
3A/4A PK
0.3%
8%
1%
-11.5V to -12.5V
MAP110-4011G
+5V
4.75V to 5.25V
12A/20A PK
12A/20A PK
0.2%
0.5%
1%
5.09V to 5.11V
+12V
Fixed
5A/9A PK
5A/9A PK
0.1%
1%
1%
11.97V to 12.03V
-12V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
1%
-11.4V to -12.6V
+24V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
1%
23.2V to 24.8V
MAP110-4015*
+5V
4.75V to 5.25V
12A/20A PK
12A/20A PK
0.2%
0.5%
1%
5.09V to 5.11V
+12V
Fixed
5A/9A PK
5A/9A PK
0.1%
1%
1%
11.97V to 12.03V
MAP110 Series
3
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2016 Bel Power Solutions & Protection
BCD.00566_AB
-15V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
1%
-14.4V to -15.6V
+15V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
1%
14.4V to 15.6V
MAP110-4200G
+12V
11.55V to
12.45V
5A/9A PK
5A/9A PK
0.2%
0.5%
0.5%
11.96V to 12.03V
+24V
Fixed
4A/4.5A PK
4A/4.5A PK
0.2%
1%
1%
23.94V to 24.06V
-12V
Fixed
1A/1.5A PK
1A/1.5A PK
0.2%
1%
1%
-11.4V to -12.6V
+5V
Fixed
2A/2.5A PK
2A/2.5A PK
0.2%
1.5%
1%
4.75V to 5.25V
MAP110-4300* 5,6
+3.3V
3.2V to 3.4V
12A/20A PK
15A/20A PK
0.3%
0.7%
1%
3.29V to 3.31V
+5V
Fixed
5A/12A PK
8A/12A PK
0.2%
1%
1%
4.98V to 5.02V
-12V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
1%
-11.4V to -12.6V
+12V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
1%
11.4V to 12.6V
MAP110-4305* 5,6
+3.3V
3.2V to 3.4V
12A/15A PK
15A/20A PK
0.3%
0.7%
1%
3.29V to 3.31V
+5V
Fixed
5A/12A PK
8A/12A PK
0.2%
1%
1%
4.98V to 5.02V
-5V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
1%
-4.75V to -5.25V
+12V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
1%
11.4V to 12.6V
1
With minimum 200LFM forced-air cooling.
2 Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3 MAP110-1024 output currents are expressed as 24V/28V operation.
4 Peak loads up to 110 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 watts.
5 Sum of the output currents of V1 + V2 may not exceed 15 A continuous, 22 A peak.
6 Maximum operating ambient temperature of 40°C
7 Non-G models use lead solder exemption and are not recommended for new designs.
* O * Obsolete
MODEL/OUTPUT OPTION
MULTIPLE OUTPUT
BOARD ONLY
SINGLE OUTPUT
BOARD ONLY
MULTIPLE OUTPUT
‘C’-COVER
SINGLE OUTPUT
C’-COVER
Convection Continuous /
Peak
80W/110W
90W/120W
60W/110W
65W/120W
Forced Air 200 LMF
110W
120W
110W
120W
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage - AC
Continuous input range
85
264
VAC
Input Frequency
AC input
47
63
Hz
Brown Out Protection
Lowest AC input voltage when regulation is maintained with full
rated loads.
85
VAC
Hold-up Time
Nominal AC input voltage (110 VAC)
50% load:
Full rated load:
40
20
mS
Input Current
85 VAC (110W load)
110VAC (110W load)
3.5
2.8
ARMS
Input Protection
Non-user serviceable internally located AC input line fuse.
Inrush Surge Current
Internally limited by thermistor. Vin = 264 VAC (one cycle). 25 °C.
41
APK
Operating Frequency
Switching frequency of main transformer, (fixed frequency).
20
25
kHz
4
MAP110 Series
tech.support@psbel.com
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Full load @ 230 VAC (Varies with distribution of loads among
outputs.)
70% typical
Minimum Loads
Single output models
Multiple output models, V1 + V28
0
1
Amps
Ripple and Noise
Full Load, 20 MHz Bandwidth.
See Model Selection Chart
Output Power
Multiple output units with convection cooling.
Multiple output units with 200 LFM forced air cooling.
5
5
80
110
Watts
Overshoot / Undershoot
Output voltage overshoot/undershoot at turn-on.
1
%
Regulation
Varies by output, regulation includes: line changes from 90-132 VAC
or 175-264, changes in load starting at 20% load and changing to
100% load.
See Model Selection Chart
Transient Response
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output only on multiple
output units).
500
µS
Turn-on Delay
Time required for initial output voltage stabilization.
1
Sec
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%.
20
mS
8 Minimum load is required only to meet the regulation limits of V3 and V4. If V3 and V4 are unused, no minimum load is necessary.
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
Provided on single output models and the
main output of multiple output models.
MAP110-1005G
MAP110-1012G
MAP110-1024G
MAP110-4200G
MAP110-4300G
All other models
6.10
17.3
32.2
13.8
3.7
5.75
7.20
20.2
37.8
16.2
4.35
6.75
V
Overload Protection
Fully protected against output overload and short circuit.
Automatic recovery upon removal of overload condition.
150
200
%
Remote Sense
Voltage drop compensated for at the load.
250
mV
Input Power Fail Warning
Option, TTL compatible logic signal. Time before regulation dropout
due to loss of input power at 110 VAC. Active low.
3
5
mS
Over temperature Protection
Option, system shutdown due to excessive internal temperature.
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
Approved to the latest edition of the following standards;
UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd.
Dielectric Withstand Voltage
Input to Chassis
Input to Output (tested by manufacturer only)
2121
4242
VDC
Electromagnetic Interference,
Conducted
FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated
EN55022 / CISPR 22 conducted
EN55022 / CISPR 22 radiated9
B
B
A
Class
Input Transient Protection
EN61000-4-5 Level 3
2
kV
Insulation Resistance
Input to output
10
MΩ
Leakage Current
Per EN60950, 264 VAC
750
μA
9 The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300.
MAP110 Series
5
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2016 Bel Power Solutions & Protection
BCD.00566_AB
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Altitude
Operating
Non-operating
10k
50k
ASL Ft.
Operating Temperature
Derate linearly above 50°C by 2.5% per °C to a max. temp. of 70°C
At 100% load:
At 50% load:
0
0
50
70
°C
Storage Temperature
-55
85
°C
Temperature Coefficient
0°C to 70°C (after 15 minute warm-up)
±0.03
±0.05
%/°C
Relative Humidity
Non-condensing
95
%RH
PARAMETER
CONDITIONS / DESCRIPTION
Dimensions
177.8 x 109.2 x 50.0 mm (7.00 x 4.30 x 1.97 inch)
Weight
0.59 kg (1.3 lbs)
Cover
Add ‘C’ suffix to model number (Please check with Factory for availability)
Power Fail Signal
Add ‘P’ suffix to model number. Provides >5 mS typical warning time before main output drops 5%.
Warning time increases at reduced load levels.
Thermal Shutdown
Add ‘T’ suffix to model number. Initiates shut-down in the event of an over temperature condition.
Automatic recovery.
Please consult factory regarding availability of a specific version.
6
MAP110 Series
tech.support@psbel.com
Figure 1. Mechanical Drawing
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.