60W AC-DC Reliable Green Industrial Adaptor GST60A ser ie s















{

ψψ










 











File Name:GST60A-SPEC 2020-10-20
(optional)
THOMAS SAMUEL
THOMAS SAMUEL
IS13252
K60950-1
TPTC004
UL62368-1 EN62368-1 J62368-1 AS/NZS60950-1
IEC62368-1MS IEC60950-1
R33100
RoHS GB4943.1
SPECIFICATION
GST60A ser ie s
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS Note. 8
SAFETY &
EMC
(Note. 9)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V
GST60A05
GST60A05-P1J
GST60A07-P1J
GST60A09-P1J
GST60A12-P1J
GST60A15-P1J
GST60A18-P1J
GST60A24-P1J
GST60A48-P1J
7.5V
GST60A07
9V
GST60A09
12V
GST60A12
15V
GST60A15
18V
GST60A18
24V
GST60A24
48V
GST60A48
120mVp-p 120mVp-p 120mVp-p 120mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±3.0% ±2.5%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±3.0% ±2.5%
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
85.5% 88.5% 89% 89.5% 89.5% 89.5% 90.5% 92%
1.4A / 115VAC 1A / 230VAC
Cold start 35A / 115AC 65A / 230VAC
0.75mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
709.7K hrs min. MIL-HDBK-217F(25)
-30 ~ +70 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85, 10 ~ 95% RH non-condensing
±0.03% / (0 ~ 50)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
125*50*31.5mm (L*W*H)
0.305Kg; 40pcs/13.02Kg/1.04CUFT
CONNECTOR
PLUG
CABLE See page 4~5 ; Other type available by customer requested







 

For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
https://www.meanwell.com/serviceDisclaimer.aspx
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
6A 6A 6A 5A 4A 3.33A 2.5A 1.25A
0 ~ 6A 0 ~ 6A 0 ~ 6A 0 ~ 4A 0 ~ 3.33A 0 ~ 2.5A
0 ~ 1.25A
30W 45W 54W 60W
0 ~ 5A
60W 60W 60W 60W
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load
50ms / 230VAC 15ms / 115VAC at full load
7.8 ~ 10.2V 9.4 ~ 12.2V 12.6 ~ 16.2V 15.7 ~ 20.3V 18.9 ~ 24.3V 25.2 ~ 32.4V 50.4 ~ 64.8V
5.2 ~ 6.8V
See page 4~5 ; Other type available by customer requested
60W AC-DC Reliable Green Industrial Adaptor
EMC IMMUNITY
EMC EMISSION
Parameter Standard
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
EN61000-3-2,GB9254
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Standard
EN61000-4-2
Test Level /Note
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-8
EN61000-4-11 95% dip 0.5 periods, 30% dip 25 periods,
95% interruptions 250 periods
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
μ
μ
File Name:GST60A-SPEC 2020-10-20
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
RF field susceptibility
EFT bursts
Surge susceptibility
Level 4, 15KV air; Level 4, 8KV contact
Conducted susceptibility
Magnetic field immunity
Voltage dips , interruption
Level 2, 3V/m
Level 3, 1KV/Line-Line , 2KV/Line-FG
Level 2, 3A/m
Level 2, 3V
Level 2, 1KV
UL62368-1, CSA C22.2 No.62368-1, TUV EN62368-1, BSMI CNS 14336-1 ,AS/NZS 60950.1, CCC GB4943.1, PSE J62368-1
BIS IS13252, KC K60950-1, EAC TP TC 004 approved; SIRIM MS IEC62368-1 (optional) approved
Derating Curve Static Characteristics
Mechanical Specification
70±10mm
UL2464 16AWG 1000±50mm for 5 ~ 9V
UL1185 16AWG 1000±50mm for 12 ~ 15V
UL1185 16AWG 1500±50mm for 18V
UL1185 18AWG 1800±50mm for 24 ~ 48V
AMBIENT TEMPERATURE ()
LOAD (%)
-30 0 2010 30 40
20
50
70
100
6050 70
INPUT VOLTAGE (VAC) 60Hz
90 10095 120110 160140 200180 240220 264
LOAD (%)
90
100
80
70
60
50
40
(HORIZONTAL)
GST60A ser ie s
Case No. GS60A Unit:mm
60W AC-DC Reliable Green Industrial Adaptor
DC output plug
Standard plug: P1J
P1J
2.1
5.5
Pin Assignment
C"+"
-V not connected to AC FG
InsideOutside
AC Inlet
IEC320-C14
Power LED
File Name:GST60A-SPEC 2020-10-20
11±0.5mm
125
31 5.
50
GST60A ser ie s
60W AC-DC Reliable Green Industrial Adaptor
File Name:GST60A-SPEC 2020-10-20
Optional DC plug: (Available in customized cable or quick adapter)
DC plug changeable through:
(1) Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
(2) Quick adapter accessory (sold separately without MOQ)
Please refer to below table and online selection guide :
Example quick adapter accessory:
P2I
P2J
P2L
P2M
5.5
5.5
5.5
5.5
2.1
2.1
2.5
2.5
P1IR
P1JR
P1LR
P1MR
5.5
5.5
5.5
5.5
2.1
2.1
2.5
2.5
9.5
9.5
P2IR
P2JR
P2LR
P2MR
5.5
5.5
5.5
5.5
2.1
2.1
2.5
2.5
5.53
5.53
5.53
5.53
2.03
2.54
2.03
2.54
12.06
12.06
9.52
9.52
Type No. ABC
OD ID L
P1I
P1L
P1M
5.5
5.5
5.5
2.1
2.5
2.5
9.5
9.5
Type No. ABC
OD ID L
Type No. ABC
OD ID L
Type No.
P3C
0.7 11.02.35
ABC
OD ID L
1.7 11.04.0
1.7 11.04.75
P3A
P3B
11.0
11.0
11.0
9.5
9.5
9.5
11.0
9.5
11.0
11.0
11.0
P2S(S761K)
P2K(761K)
P2C(S760K)
P2D(760K)
Tuning Fork Style
Barrel Style
Lock Style
Min. Pin Style
B
A
A
B
C
(Straight)
C
(Right-angled)
C
(Straight)
C
(Right-angled)
C
EIAJ equivalent
C
Floating Locking
SWITCHCRAFT original or equivalent
Quick Adapter
Accessory
Available
None
None
P4C 5.1 11.0
7.4 0.6
A
B
D
3.4 11.0
5.5
4.4 11.0
6.5
1.0
1.4
P4A
P4B
Type No. ABD
OD ID
Center Pin
C
L
Center Pin Style
C
EIAJ equivalent
B
A
A
B
(Current rating: 7.5A max.)
(Current rating: 5A max.)
(Current rating: 7.5A max.)
Available
Available
GST60A ser ie s
60W AC-DC Reliable Green Industrial Adaptor
File Name:GST60A-SPEC 2020-10-20
Installation Manual
R1B
25
3
1
4
Length of Land L1 by request
( ’s standard length, L: mm, L1: mm)
MW 25 5
(red)
(black)
by customer
2
1
L1
L
2
1
R7B
+Vo
-Vo
Type No.
Min. DIN 4 Pin with Lock (male)
Stripped and tinned leads
+Vo
-Vo
Pin Assignment
PIN No.Output
Pin Assignment
PIN No.Output
Type No.
1
2
3
4+Vo
-Vo
KYCON KPPX-4P equivalent
R6B
Type No. PIN No.Output
1
2
3
+Vo
-Vo
+Vo
Min. DIN 3 Pin with Lock (male)
KYCON KPPX-3P equivalent
Pin Assignment
R7BF
+Vo
-Vo
Type No.
KYCON KPJX-CM-4S equivalent
Pin Assignment
PIN No.Output
1
2
3
4+Vo
-Vo
Min. DIN 4 Pin with Lock (female)
Available
None
None
-Vo
-Vo
Type No. Pin Assignment
PIN No.Output
1
2
3
4-Vo
+Vo
DIN 5 Pin (male)
5+Vo
Quick Adapter
Accessory
1
2
4
3
2
1
3
2
1 4
3
(Current rating: 7.5A max.)
Available
(Current rating: 7.5A max.)
Available
(Current rating: 7.5A max.)
Please refer to : http://www.meanwell.com/manual.html