For more information, please visit the product page. date 07/03/2018 page 1 of 8 SERIES: PDS1-M DESCRIPTION: DC-DC CONVERTER FEATURES * * * * * * * * * 1 W isolated output smaller package single and dual unregulated outputs 1,500 Vdc isolation short circuit protection extended temperature range (-40~105C) antistatic protection up to 8kV high efficiency at light load efficiency up to 82% MODEL input voltage output voltage output current output power ripple and noise2 efficiency typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) typ (mVp-p) typ (%) PDS1-S3-S3-M 3.3 2.97~3.63 3.3 30 303 1 60 69 PDS1-S3-S5-M 3.3 2.97~3.63 5 20 200 1 60 74 PDS1-S3-D5-M 3.3 2.97~3.63 5 10 100 1 60 76 PDS1-S3-D12-M 3.3 2.97~3.63 12 5 42 1 60 77 PDS1-S3-D15-M 3.3 2.97~3.63 15 3 33 1 60 78 1 PDS1-S5-S3-M 5 4.5~5.5 3.3 30 303 1 60 72 PDS1-S5-S5-M1 5 4.5~5.5 5 20 200 1 60 80 PDS1-S5-S9-M 5 4.5~5.5 9 12 111 1 60 80 PDS1-S5-S12-M1 5 4.5~5.5 12 9 84 1 60 80 1 PDS1-S5-S15-M 5 4.5~5.5 15 7 67 1 60 80 PDS1-S5-S24-M1 5 4.5~5.5 24 4 42 1 60 80 PDS1-S5-D5-M 5 4.5~5.5 5 10 100 1 60 80 PDS1-S5-D9-M 5 4.5~5.5 9 6 56 1 60 80 PDS1-S5-D12-M 5 4.5~5.5 12 5 42 1 60 79 PDS1-S5-D15-M 5 4.5~5.5 15 3 33 1 60 81 PDS1-S5-D24-M 5 4.5~5.5 24 2 21 1 60 81 1 PDS1-S12-S3-M 12 10.8~13.2 3.3 30 303 1 60 72 PDS1-S12-S5-M1 12 10.8~13.2 5 20 200 1 60 80 PDS1-S12-S9-M 12 10.8~13.2 9 12 111 1 60 80 PDS1-S12-S12-M1 12 10.8~13.2 12 9 84 1 60 80 PDS1-S12-S15-M 12 10.8~13.2 15 7 67 1 60 80 PDS1-S12-D5-M 12 10.8~13.2 5 10 100 1 60 80 PDS1-S12-D9-M 12 10.8~13.2 9 6 56 1 60 80 PDS1-S12-D12-M 12 10.8~13.2 12 5 42 1 60 81 PDS1-S12-D15-M 12 10.8~13.2 15 3 33 1 60 81 PDS1-S12-D24-M 12 10.8~13.2 24 2 21 1 60 81 PDS1-S15-S15-M 15 13.5~16.5 15 7 67 1 60 80 1 1 1 1 Notes: 1. UL approved 2. Ripple and noise are measured at 20 MHz BW by "parallel cable" method with 1 F ceramic and 10 F electrolytic capacitors on the output. cui.com For more information, please visit the product page. CUI Inc SERIES: PDS1-M DESCRIPTION: DC-DC CONVERTER MODEL (CONTINUED) input voltage date 07/03/2018 page 2 of 8 output voltage output current output power ripple and noise2 efficiency typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) typ (mVp-p) typ (%) PDS1-S24-S5-M1 24 21.6~26.4 5 20 200 1 60 80 PDS1-S24-S9-M1 24 21.6~26.4 9 12 111 1 60 80 PDS1-S24-S12-M 24 21.6~26.4 12 9 84 1 60 80 PDS1-S24-S15-M1 24 21.6~26.4 15 7 67 1 60 80 PDS1-S24-S24-M 24 21.6~26.4 24 4 42 1 60 80 PDS1-S24-D5-M 24 21.6~26.4 5 10 100 1 60 80 PDS1-S24-D9-M 24 21.6~26.4 9 6 56 1 60 80 PDS1-S24-D12-M 24 21.6~26.4 12 5 42 1 60 81 PDS1-S24-D15-M 24 21.6~26.4 15 3 33 1 60 82 PDS1-S24-D24-M 24 21.6~26.4 24 2 21 1 60 80 1 Notes: 1. UL approved 2. Ripple and noise are measured at 20 MHz BW by "parallel cable" method with 1 F ceramic and 10 F electrolytic capacitors on the output. PART NUMBER KEY PDS1 - SXX - XXX - M - X Base Number Input Voltage Output S = single D = dual Output Voltage Packaging Style SMT Package Options "blank" = standard TR = Tape & Reel INPUT parameter conditions/description min typ max units operating input voltage 3.3 Vdc input models 5 Vdc input models 12 Vdc input models 15 Vdc input models 24 Vdc input models 2.97 4.5 10.8 13.5 21.6 3.3 5 12 15 24 3.63 5.5 13.2 16.5 26.4 Vdc Vdc Vdc Vdc Vdc surge voltage for maximum of 1 second 3.3 Vdc input models 5 Vdc input models 12 Vdc input models 15 Vdc input models 24 Vdc input models -0.7 -0.7 -0.7 -0.7 -0.7 5 9 18 21 30 Vdc Vdc Vdc Vdc Vdc filter capacitance filter max units 1.5 1.2 % % OUTPUT parameter conditions/description min line regulation for Vin change of 1% 3.3 Vdc output models all other models load regulation measured from 10% load to full load 3.3 Vdc output models 5 Vdc output models 9 Vdc output models 12 Vdc output models 15 Vdc output models 24 Vdc output models voltage accuracy see tolerance envelope curve switching frequency 100% load, nominal input voltage temperature coefficient 100% load typ 18 12 8 7 6 5 % % % % % % 100 kHz 0.03 cui.com %/C For more information, please visit the product page. CUI Inc SERIES: PDS1-M DESCRIPTION: DC-DC CONVERTER date 07/03/2018 page 3 of 8 PROTECTIONS parameter conditions/description short circuit protection1 3 & 24 Vdc input models PDS1-S5-S12-M, PDS1-S5-D24-M all other models: automatic recovery Note: min typ max units 1 1 s s max units 1. The supply voltage must be discontinued at the end of the short circuit duration SAFETY AND COMPLIANCE parameter conditions/description isolation voltage input to output for 1 minute at 1 mA max. 1,500 Vdc isolation resistance input to output at 500 Vdc 1,000 M isolation capacitance input to output at 100 kHz/0.1 V safety approvals2 UL 60950-1 conducted emissions CISPR32/EN55032, class B (external circuit required, see Figure 1) radiated emissions CISPR32/EN55032, class B (external circuit required, see Figure 1) ESD IEC/EN 61000-4-2, class B, contact 8kV (single output models) IEC/EN 61000-4-2, class B, contact 6kV (dual output models) MTBF as per MIL-HDBK-217F @ 25 C RoHS 2011/65/EU Note: min typ 20 pF 3,500,000 hours 2. See specific models noted on pages 1 & 2 ENVIRONMENTAL parameter conditions/description min operating temperature see derating curve storage temperature storage humidity non-condensing temperature rise at full load, Ta=25C typ max units -40 105 C -55 125 C 95 25 % C SOLDERABILITY parameter conditions/description max units hand soldering 1.5 mm from case for 10 seconds min 300 C reflow soldering see reflow soldering profile 245 C 25 0 24 5 Peak .Temp 245C( Max.) 21 7 Tem peratur e (C ) 20 0 60 Sec Max ( >217 C) 15 0 10 0 50 0 typ Tim e (se c.) cui.com For more information, please visit the product page. CUI Inc SERIES: PDS1-M DESCRIPTION: DC-DC CONVERTER date 07/03/2018 page 4 of 8 MECHANICAL parameter conditions/description dimensions single output models: 12.7 x 8.30 x 7.25 dual output models: 15.24 x 8.30 x 7.25 min case material epoxy resin (UL94-V0) weight single output models dual output models SINGLE OUTPUT MODELS units: mm[inch] tolerance: 0.25[0.010] pin section tolerance: 0.10[0.004] PIN CONNECTIONS Function 1 GND 2 Vin 4 0V 5 +Vo 8 NC cui.com max units mm mm 1.6 2.0 MECHANICAL DRAWING PIN typ g g For more information, please visit the product page. CUI Inc SERIES: PDS1-M DESCRIPTION: DC-DC CONVERTER date 07/03/2018 page 5 of 8 MECHANICAL DRAWING (CONTINUED) DUAL OUTPUT MODELS units: mm[inch] tolerance: 0.25[0.010] pin section tolerance: 0.10[0.004] PIN CONNECTIONS PIN Function 1 GND 2 Vin 4 0V 5 -Vo 7 +Vo 10 NC cui.com For more information, please visit the product page. CUI Inc SERIES: PDS1-M DESCRIPTION: DC-DC CONVERTER date 07/03/2018 page 6 of 8 Tolerance Envelope Curve (3.3 Vdc output only) 10 5 Max Typ ic al L oad Lin 0 Output Voltage Accuracy (%) Output Voltage Accuracy (%) DERATING CURVES 1.0 Rated Output Voltage e -5 -7.5 Min -10 -15 -15 10 20 40 60 80 15 Tolerance Envelope Curve (all other models) 10 Typic al 5 0 2.5 Rated Output Voltage Min -5 -2.5 -7.5 -10 10 100 Max Load Line 20 40 60 80 100 Output Current Percentage (%) (Nominal Input Voltage) Output Current Percentage (%) (Nominal Input Voltage) Temperature Derating Curve Load (%) 100 80 60 Safe operating area 40 20 -40 -20 0 20 40 60 80 100105 120 Ambient Temperature (C) EMC RECOMMENDED CIRCUIT Figure 1 Table 1 LDM Vin Vin C1 GND +Vo DC / DC GND C2 LO A D Single Outputs 0V LDM Vin Vin C1 GND GND Vin (Vdc) C1 C21 LDM CY2 3.3 4.7F/50V - 6.8H - 5 4.7F/50V - 6.8H - 12 4.7F/50V - 6.8H - 15 4.7F/50V - 6.8H 1nF/2kV 4.7F/50V - 6.8H 1nF/2kV 24 +Vo DC/DC Recommended external circuit components Dual Outputs C2 LOAD -Vo CY cui.com Note: 1. See Cout values in Tables 2 & 3. 2. 24 Vdc output models require CY also. For more information, please visit the product page. CUI Inc SERIES: PDS1-M DESCRIPTION: DC-DC CONVERTER date 07/03/2018 page 7 of 8 APPLICATION NOTES 1. Output load requirement To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load. 2. Overload Protection Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add this is to add a circuit breaker to the circuit. 3. Recommended circuit If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low ESR (see Figure 3 & Table 3). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance must be less than the maximum capacitive load (see Table 4). Figure 2 Single Output +Vo Vin DC DC Cin GND Dual Output Vin Cout DC DC Cin GND 0V Table 3 Vin (Vdc) Cin (F) Single Vo (Vdc) Cout (F) 3.3 4.7 3.3 10 5 4.7 5 10 12 2.2 9 4.7 9 15 2.2 12 2.2 12 24 1 15 1 - - 24 0.47 4. 0V Cout -Vo Table 2 Note: +Vo Cout Dual Vo (Vdc) Max. Capacitive Load1 (F) Cout (F) Single Vout (Vdc) Max. Capacitive Load (F) - - 3.3 220 - - 5 4.7 5 220 5 100 2.2 9 220 9 100 1 12 220 12 100 15 1 15 220 15 100 24 0.47 24 220 24 100 It's not recommended to connect any external capacitors in applications with less than 0.5 watt output. Note: Dual Vout (Vdc) 1. For each output. Output Voltage Regulation and Over-voltage Protection Circuit The device for output voltage regulation, over-voltage and over-current protection is a linear regulator and a capacitor filtering network with overheat protection which can be connected to the input or output end in series (see Figure 4). The recommended capacitance of its filter capacitor (see Table 3), and the linear regulator is based on the actual voltage and current required. Figure 3 Single Output Vin REG GND Note: Dual O ut put REG +Vo DC DC 0V 1. 2. 3. 4. Vin GND REG REG +Vo DC DC 0V REG -Vo Operation under minimum load will not damage the converter; however, they may not meet all specifications listed. Max. capacitive load tested at input voltage range and full load. It is recommended to use either ceramic capacitors or electrolytic capacitors on the input and the output. Using tantalum capacitors may increase the risk of failure. All specifications measured at: Ta=25C, humidity<75%, nominal input voltage and rated output load, unless otherwise specified. cui.com For more information, please visit the product page. CUI Inc SERIES: PDS1-M DESCRIPTION: DC-DC CONVERTER date 07/03/2018 page 8 of 8 REVISION HISTORY rev. description date 1.0 initial release 03/19/2013 1.01 added PDS1-S24-S12-M model 06/11/2013 1.02 added dual output models 02/17/2014 1.03 added models PDS1-S3-S3-M, PDS1-S3-S5-M, PDS1-S5-S3-M, and PDS1-S12-S3-M 04/18/2014 1.04 added UL approval to some models, updated spec 10/03/2014 1.05 updated datasheet 07/03/2018 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.