AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC05-K/277
Series
www.recom-power.com REV.: 1/2018 PA-5
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Audio/Video, information and communication technology equipment - Part
1: Safety requirements E491408-A6004 UL62368-1, 2nd Edition, 2014-12-01
CAN/CSA-C22.2 No. 62368-1-14, 2nd Edition, 2014-12
Audio/Video, information and communication technology equipment -
Part 1: Safety requirements (CB Scheme)
E491408-A6007-CB-1
IEC62368-1:2014 2nd Edition
Audio/Video, information and communication technology equipment -
Part 1: Safety requirements (LVD)
EN62368-1:2014 + A11:2017
Household and similar electrical appliances - Safety -
Part 1: General requirements pending IEC60335-1:2010 + A2:2016 + C1:2016 5th Edition
EN60335-1:2012 + A11:2014
Measurement methods for electromagnetic fields of household appliances
and similar apparatus with regard to human exposure pending EN62233:2008
RoHS2+ RoHS-2011/65/EU + AM-2015/863
EMC Compliance Conditions Standard / Criterion
Low-voltage power supplies DC output - Part 3: Electromagnetic compatibility
EN61204-3: 2018, Class B
Electromagnetic compatibility of multimedia equipment - Emission requirements
EN55032:2015, Class B
Electromagnetic compatibility - Requirements for household appliances,
electric tools and similar apparatus - Part 1: Emission
EN55014-1:2006 + A2:2011
Information technology equipment - Immunity characteristics - Limits and
methods of measurement
EN55024:2010 + A1:2015
Electromagnetic compatibility - Requirements for household appliances,
electric tools and similar apparatus - Part 2: Immunity
EN55014-2:2015
ESD Electrostatic discharge immunity test
Air: ±2, 4, 8kV
Contact: ±2, 4kV EN61000-4-2: 2009, Criteria B
Radiated, radio-frequency, electromagnetic field immunity test
10V/m, 80MHz-1GHz
3V/m, 1.4GHz-2GHz
1V/m, 2GHz-2.7GHz
EN61000-4-3: 2006 + A1, 2009, Criteria A
Fast Transient and Burst Immunity
AC and DC Port: ±2kV EN61000-4-4: 2012, Criteria B
Surge Immunity
AC In Port (L-N): ±1kV
DC Output Port: ±0.5kV EN61000-4-5: 2014 +A1:2017, Criteria B
Immunity to conducted disturbances, induced by radio-frequency fields
AC and DC Port: 10V EN61000-4-6: 2014, Criteria A
Power Magnetic Field Immunity
50Hz, 30A/m EN61000-4-8: 2010, Criteria A
Voltage Dips and Interruptions
Voltage Dips: 30%
Voltage Dips: 60%
Voltage Dips: 100%
Interruptions: >95%
EN61000-4-11:2004 + A1:2017, Criteria C
EN61000-4-11:2004 + A1:2017, Criteria C
EN61000-4-11:2014 + A1:2017, Criteria B
EN61000-4-11: 2014 + A1:2017,Criteria C
Voltage Fluctuations and Flicker in Public Low-Voltage Systems <=16A per phase
EN61000-3-3: 2013
Limitations on the amount of electromagnetic intererence allowed from digital
and electronic devices
FCC 47 CFR Part 15 Supbart B, Class B
Methods of Measurement of Radio-Noise Emissions from Low-Voltage
Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz ANSI C63.4-2014, Class B
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter Type Value
Material
case, baseplate
potting
plastic, (UL94 V-0)
silicone, (UL94 V-0)
FR4, (UL94 V-0)
Dimension (LxWxH) THT/wired 31.7 x 26.7 x 21.8mm
Weight THT
wired
31.5g typ.
37.0g typ.
continued on next page