DATA SHEET
Ametherm, Inc. 3111 N. Deer Run Road #4 Carson City, NV 89701
Telephone: (800) 808-2434 (775) 884-2434 Fax: (775) 884-0670
www.ametherm.com
Part Number: SL12 10006-03
Ordering Different Lead Types:
For example: to order an inside kinked lead use part number SL12 10006-03-A
Electrical Specifications: Mechanical Specifications:
CSA File Number: #CA118061 Revision Date: March 19, 2003
Inside Kinked Leads Use -A after Ametherm’s part #
Outside Kinked Leads Use -B after Ametherm’s part #
Resistance @ 25°C 10.0 ± 20%
Max Steady State Current Up to 65°C 6.0 A
Max Recommended Energy Rating (Joul es) 40.0 J
Actual Failure Point of Instantaneous Energy (Joules) 80.0 J
Resistance @ 100% of Max Current 0.120
Resistance @ 50% of Max Current 0.242
Body Temperature @ 100% Current Rating 177 °C
Dissipation Constant 13.5mW/°C
The rmal Time Co nst ant 42 second s
Material Type “C”
Max Recommended Capacitance @ 120VAC/240VAC 2700µF/690µF
D 12.0 ± 0.5 mm
T 5.1 ± 0.2 mm
Lead Diameter 1.0 ± 0.1 mm
S 7.8 ± 2.0 mm
L 38.0 ± 9.0 mm
Straight Leads
Coati ng Run Down 5.0 ± 1.0 mm
B 6.35 ± 0.60 mm
C 3.42 ± 0.5 mm
L
OUTSIDE
KINKED LEADS
S
STRAIGHT
LEADS
B
INSIDE
KINKED LEADS
S S
D D D
C
T