cui.com
date 07/23/2020
page 1 of 5
SERIES: SDI200-U DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• level VI efficiency
• 200 W power
• universal input (90~264 Vac)
• single regulated outputs
• over voltage and short circuit protections
• UL/cUL (60950-1 & 62368-1), PSE safety approvals
• power factor correction
• custom designs available
MODEL output
voltage
output
current
output
power
ripple
and noise1
eciency
level
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
SDI200-12-U 12 16 192 150 VI2
SDI200-13.5-U 13.5 14 189 200 VI
SDI200-19-U 19 10.5 200 190 VI
SDI200-24-U 24 8.3 200 240 VI2
SDI200-48-U 48 4.17 200 480 VI2
SDI200-56-U 56 3.58 200 560 VI2
Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope, output terminated with 0.1 µF multilayer ceramic and 10 µF low ESR electrolytic capacitors.
2. CoC Tier 2 compliant.
PART NUMBER KEY
Base Number Reserved for Custom
Congurations
SDI200 - XX - UX - P51 - CXX
DC Plug Type:
4 Pin Power DIN
Output Voltage
Input Cable:
“Blank” = No Cable
C = North America input cable
2 = Europe input cable
3 = United Kingdom input cable
4 = Australia input cable
5 = China input cable
6 = South Korea input cable
7 = Brazil input cable
8 = South Africa input cable
9 = Japan input cable
AC Inlet Type:
IEC320/C14
Additional Resources: Product Page | 3D Model
cui.com
date 07/23/2020 page 2 of 5CUI Inc SERIES: SDI200-U DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 90 264 Vac
frequency 47 63 Hz
current 2.8 A
inrush current at 240 Vac, full load, 25°C, cold start 100 A
leakage current 3.5 mA
power factor correction at 115/230 Vac, full load 0.9
no load power consumption 12, 24, 48, 56 Vdc output models
all other models
0.15
0.21
W
W
OUTPUT
parameter conditions/description min typ max units
regulation ±5 %
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection output latch 150 %
over current protection output shut down, auto recovery 150 %
short circuit protection output shut down
over temperature protection output latch
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage input to output at 10 mA for 1 minute
input to ground at 10 mA for 1 minute
3,000
1,500
Vac
Vac
isolation resistance input to output at 500 Vdc
input to ground at 500 Vdc
10
10
MΩ
MΩ
safety approvals UL/cUL (60950-1, 62368-1), PSE
EMI/EMC FCC Part 15B Class B, CE
MTBF as per Telcordia SR-332, 25°C 300,000 hours
RoHS yes
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature 0 40 °C
storage temperature -20 80 °C
operating humidity non-condensing 20 80 %
storage humidity non-condensing 10 90 %
Additional Resources: Product Page | 3D Model
cui.com
date 07/23/2020 page 3 of 5CUI Inc SERIES: SDI200-U DESCRIPTION: AC-DC POWER SUPPLY
DC CORD
cord length
MECHANICAL
parameter conditions/description min typ max units
dimensions 183.2 x 81.0 x 42.3 mm
inlet plug IEC320/C14
weight without ac cord 820 g
MECHANICAL DRAWING
units: mm
tolerance: ±1.0 mm
units: mm
Table 1
MODEL NO. CABLE CORD LENGTH
SDI200-12-U UL2464, 16 AWG, 4C 1,200 mm ±30
SDI200-13.5-U UL2464, 16 AWG, 4C 1,200 mm ±30
SDI200-19-U UL2464, 16 AWG, 4C 1,500 mm ±30
SDI200-24-U UL2464, 16 AWG, 4C 1,500 mm ±30
SDI200-48-U UL2464, 18 AWG, 4C 1,500 mm ±30
SDI200-56-U UL2464, 18 AWG, 4C 1,500 mm ±30
Additional Resources: Product Page | 3D Model
cui.com
date 07/23/2020 page 4 of 5CUI Inc SERIES: SDI200-U DESCRIPTION: AC-DC POWER SUPPLY
AC CORD
NORTH AMERICA EUROPE
AUSTRALIA
UNITED KINGDOM
CHINA
units: mm
cord length
SOUTH KOREA
SOUTH AFRICA
BRAZIL JAPAN
AC INPUT CORD LENGTH
North America 1,830 mm ±30
Europe 1,830 mm ±30
United Kingdom 1,830 mm ±30
Australia 1,830 mm ±30
China 1,830 mm ±30
South Korea 1,830 mm ±50
Brazil 1,830 mm ±30
South Africa 1,830 mm ±50
Japan 1,830 mm ±30
Table 2
Additional Resources: Product Page | 3D Model
date 07/23/2020 page 5 of 5CUI Inc SERIES: SDI200-U DESCRIPTION: AC-DC POWER SUPPLY
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI oers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
aect its safety or eectiveness.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
rev. description date
1.0 initial release 08/28/2018
1.01 company logo updated 07/23/2020
The revision history provided is for informational purposes only and is believed to be accurate.
REVISION HISTORY
Additional Resources: Product Page | 3D Model