DIMENSIONS
Type 267 is specially designed to SMD, based on our technology of chip tantalum capacitors acquired over many years.
Fully-molded construction provides excellent mechanical protection, superior moisture resistance and high soldering heat
resistance. Type 267 E Series has increased capacitance. Its volume efficiency is greatly improved compared to the same
case size of M series.
1. Type 267 E Series has increased capacitance. Its volume efficiency is greatly improved compared to the same case
size of M series.
2. Dimensional accuracy and symmetrical terminal structure suitable for high-density mounting ensures excellent
"Self-Alignment".
3. Soldering: 260 for 10 seconds by re-flow soldering.
4. Lead-free and RoHS Compliant
Item
Rating
Category temperature range (Operating temperature )
-55 ~ +125°C
Rated Temperature (Maximum operating temperature for DC rated Voltage)
+85°C
DC rated voltage rangeUR
See CATALOG NUMBERS AND
RATING OF EXTENDED PRODUCTS
Rated capacitance (Normal capacitance rangeCR)
Rated capacitance tolerance
Failure rate level
1%/1000 h
Note(1): For operation 125,derate voltage linearly to 67% of 85 voltage rating.
(mm)
Case code
EIA Code
L±0.2
W±0.2
T±0.2
P1±0.2
P2 min.
C±0.1
A
3216
3.2
1.6
1.6
0.75
1.4
1.2
B
3528
3.5
2.8
1.9
0.8
1.5
2.2
C3
6032
6.0
3.2
2.5
1.3
3.0
2.2
D3
7343
7.3
4.4
2.8
1.3
4.0
2.4
H
7343H
7.3
4.4
4.1
1.3
4.0
2.4
FEATURES
RATING
Type
267 E
Series
ORDERING INFORMATION
267 E1602 106 M R 533
TYPE SERIES
RATED
VOLTAGE CAPACITANCE
CAPACITANCE
TOLERANCE
STYLE OF REELED
PACKAGE
SPECIAL CODE
[D3, H case] [C3 case]
[B case][A case]
W
T
T
W
T
W
L
P1P2
C
P1
W
T
Marking
Rated
voltage
Marking Capacitance Marking Capacitance
Marking
Capacitance
Tolerance
Code Reel Size AnodeNotation
2501 2.5VDC 224
0.22 m226 22 mK ±10% R φ180 Reel Feed hole: -
4001 4DVC 684
0.68 m336 33 mM ±20% L φ180 Reel Feed hole: +
6301 6.3DVC 105
1.0 m476 47 mNφ330 Reel Feed hole: -
1002 10VDC 155
1.5 m686 68 mPφ330 Reel Feed hole: +
1602 16VDC 225
2.2 m107 100 m
2002 20VDC 335
3.3 m157 150 m
2502 25VDC 475
4.7 m227 220 m
3502 35VDC 685
6.8 m337 330 m
5002 50VDC 106
10 m477 470 m
156
15 m687 680 m
Taping specification
1
Note (1): Date codes are based on the Annex 1 Table 13 of JIS C 5101-1.
Note (2): Rated voltage codes
Rated voltage
2.5
4
6.3
10
16
20
25
35
50
code
e
g
j
A
C
D
E
V
H
Note (3): Rated capacitance codes
Capacitance µF
100
150
220
330
470
680
Code
A8
E8
J8
N8
S8
W8
Note (4): First two digits are significant figures of capacitance value(pF).Third digit is the number of zeros following.
(mm)
Case code
EIA Code
a
b
c
Flow
Reflow
A
3216
3.0
2.0
1.5
1.5
B
3528
3.2
2.0
2.4
1.8
C3
6032
4.2
2.4
2.5
3.3
D3
7343
5.2
2.4
2.7
4.6
H
7343H
5.2
2.4
2.7
4.6
MARKING
STANDARD RATING
RECOMMENDED SOLDER PAD LAYOUT
a
b
c
MARKING
R.V.(VDC)
Cap.( mF )
0.22
A
0.33
0.47
0.68
A B
1.0
A A
1.5
A A
2.2
A A A A, B C3
3.3
A A A A, B B
4.7
A A A A, B A, B D3
6.8
A A A A, B A, B B C3
10
A A A, B A, B B B, C3 C3
15
A A A, B A, B A, B C3 C3 D3
22
A A, B A, B A, B B, C3 C3 C3, D3 D3
33
A, B A, B A, B A, B, C3 B, C3 D3 D3
47
A, B A, B A, B, C3 B, C3 C3, D3 D3
68
A, B A, B, C3 A, B, C3 B, C3, D3 C3, D3 H
100
A, B A, B, C3 A, B, C3, D3 B, C3, D3 D3, H H H
150
A, B A, B, C3, D3 B, C3, D3 C3, D3, H
220
A, B, C3 B, C3, D3 C3, D3, H C3, D3, H
330
C3, D3 C3, D3, H H
470
C3, D3 D3 H
680
D3 D3
2.5
50
35
4
6.3
10
16
20
25
[A case ]
C2.2A
Rated voltage (
2
)
Rated capacitance
Date code (
1
)
Capacitance tolerance
(+/-10% notation)
Polarity (Anode notation)
[C3, D3, H case]
106K
16 A
Capacitance tolerance
(K:+/-10%)
[B case]
474
35 A
Capacitance tolerance
(+/-10% notation)
Rated capacitance (
4
)
Date code (
1
)
Rated voltage
Polarity (Anode notation)
jA8A
Rated voltage (
2
)
Rated capacitance (
3
)
Date code (
1
)
Capacitance tolerance
(+/-10% notation)
Polarity (Anode notation)
Less than 100µF
100µF or more
2
CATALOG NUMBERS AND RATING OF EXTENDED PRODUCTS
Catalog Number (
1
)(
2
)
UR
VDC
US
VDC
CR
µF
Case
code
Leakage current(DCL)
µA
Variation rate of
cap.
(ΔC/C)%
Dissipation factor
ESR
Ω
Surge
Resistance to soldering
heat
Resistance
to solvent
Temp. cycling
Damp heat
Life
85
125
20
85
125
-55
85
125
-55
20
85
125
10kHz
100kHz
DCL(
3
)
ΔC/C%
DCL(
3
)
ΔC/C%
ΔC/C%
DCL(
3
)
ΔC/C%
DCL(
3
)
ΔC/C%
DCL(
3
)
ΔC/C%
267E 2501 156 _
1
_
2
2.5
3.3
2.2
15
A
0.5
5
6.3
±10
±10
±15
0.12
0.08
0.08
0.10
7.5
7.2
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 2501 226 _
1
_
2
22
A
0.6
6
6.9
±10
±10
±15
0.12
0.08
0.08
0.10
7.5
7.1
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 2501 336 _
1
_
2
533
33
A
0.8
8
10
±10
±10
±15
0.12
0.08
0.08
0.10
7.5
7.1
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 2501 336 _
1
_
2
33
B
0.8
8
10
±10
±10
±15
0.12
0.08
0.08
0.10
3.0
2.8
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 2501 476 _
1
_
2
533
47
A
1.2
12
15
±10
±10
±15
0.15
0.08
0.08
0.10
7.5
7.1
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 2501 476 _
1
_
2
47
B
1.2
12
15
±10
±10
±15
0.12
0.08
0.08
0.10
3.0
2.8
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 2501 686 _
1
_
2
533
68
A
1.7
17
21
±20
±20
±20
0.30
0.18
0.18
0.22
7.5
7.1
A
±10
A
±10
±3
A
±20
C
±10
C
±15
267E 2501 686 _
1
_
2
68
B
1.7
17
21
±10
±10
±15
0.12
0.08
0.08
0.10
3.0
2.7
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 2501 107 _
1
_
2
534
100
A
2.5
25
32
±20
±20
±20
0.30
0.18
0.18
0.22
7.5
7.1
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 2501 107 _
1
_
2
533
100
B
2.5
25
31
±10
±10
±15
0.25
0.12
0.12
0.12
5.0
4.7
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 2501 157 _
1
_
2
534
150
A
3.8
76
95
±20
±20
±20
0.32
0.20
0.20
0.20
2.5
2.0
C
±20
C
±20
±3
C
±20
C
±20
C
±30
267E 2501 157 _
1
_
2
533
150
B
3.8
38
47
±20
±20
±20
0.30
0.16
0.16
0.18
5.0
4.7
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 2501 227 _
1
_
2
535
220
A
5.5
110
137
±20
±20
±20
0.36
0.24
0.24
0.24
2.5
2.0
C
±20
C
±20
±3
C
±20
C
±20
C
±30
267E 2501 227 _
1
_
2
534
220
B
5.5
55
69
±20
±20
±20
0.34
0.18
0.18
0.20
5.0
4.7
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 2501 227 _
1
_
2
734
220
C3
5.5
55
69
±10
±10
±15
0.22
0.12
0.12
0.14
1.0
0.95
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 4001 685 _
1
_
2
4
5
3.2
6.8
A
0.5
5
6.3
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.2
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 4001 106 _
1
_
2
10
A
0.5
5
6.3
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.2
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 4001 156 _
1
_
2
15
A
0.6
6
7.5
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.1
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 4001 226 _
1
_
2
533
22
A
0.9
9
11
±10
±10
±15
0.12
0.08
0.08
0.10
7.5
7.1
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 4001 226 _
1
_
2
22
B
0.9
9
11
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.8
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 4001 336 _
1
_
2
533
33
A
1.3
13
17
±10
±10
±15
0.12
0.08
0.08
0.10
7.5
7.1
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 4001 336 _
1
_
2
33
B
1.3
13
17
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.8
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 4001 476 _
1
_
2
533
47
A
1.9
19
24
±20
±20
±20
0.20
0.12
0.12
0.14
7.5
7.1
A
±10
A
±10
±3
A
±20
C
±10
C
±15
267E 4001 476 _
1
_
2
47
B
1.9
19
24
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.7
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 4001 686 _
1
_
2
534
68
A
2.7
27
34
±20
±20
±20
0.30
0.18
0.18
0.22
7.5
7.1
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 4001 686 _
1
_
2
533
68
B
2.7
27
34
±10
±10
±15
0.20
0.10
0.10
0.10
3.0
2.7
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 4001 686 _
1
_
2
720
68
C3
2.7
27
34
±10
±10
±15
0.08
0.06
0.06
0.08
0.6
0.55
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 4001 107 _
1
_
2
534
100
A
4.0
40
50
±20
±20
±20
0.30
0.18
0.18
0.22
7.5
7.1
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 4001 107 K _
2
533
100
B
4.0
40
50
±20
±20
±20
0.22
0.12
0.12
0.14
5.0
4.7
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 4001 107 M _
2
533
100
B
4.0
40
50
±10
±10
±15
0.25
0.12
0.12
0.12
5.0
4.7
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 4001 107 _
1
_
2
720
100
C3
4.0
40
50
±10
±10
±15
0.10
0.08
0.08
0.08
1.0
0.95
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 4001 157 _
1
_
2
535
150
A
6.0
120
150
±20
±20
±20
0.32
0.20
0.20
0.20
2.5
2.0
C
±20
C
±20
±3
C
±20
C
±20
C
±30
267E 4001 157 _
1
_
2
534
150
B
6.0
60
75
±20
±20
±20
0.34
0.18
0.18
0.20
5.0
4.7
A
±10
A
±10
±3
A
±20
C
±10
C
±20
February, 2011
3
Catalog Number (
1
)(
2
)
UR
VDC
US
VDC
CR
µF
Case
code
Leakage current(DCL)
µA
Variation rate of
cap.
(ΔC/C)%
Dissipation factor
ESR
Ω
Surge
Resistance to soldering
heat
Resistance
to solvent
Temp. cycling
Damp heat
Life
85
125
20
85
125
-55
85
125
-55
20
85
125
10kHz
100kHz
DCL(
3
)
ΔC/C%
DCL(
3
)
ΔC/C%
ΔC/C%
DCL(
3
)
ΔC/C%
DCL(
3
)
ΔC/C%
DCL(
3
)
ΔC/C%
267E 4001 157 _
1
_
2
734
4
5
3.2
150
C3
6.0
60
75
±10
±10
±15
0.12
0.08
0.08
0.10
1.0
0.95
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 4001 157 _
1
_
2
720
150
D3
6.0
60
75
±10
±10
±15
0.10
0.08
0.08
0.08
0.5
0.45
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 4001 227 M _
2
534
220
B
8.8
88
110
±20
±20
±20
0.34
0.18
0.18
0.20
5.0
4.7
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 4001 227 _
1
_
2
734
220
C3
8.8
88
110
±10
±10
±15
0.22
0.12
0.12
0.14
1.0
0.95
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 4001 227 _
1
_
2
720
220
D3
8.8
88
110
±10
±10
±15
0.15
0.08
0.08
0.10
0.5
0.45
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 4001 337 _
1
_
2
735
330
C3
13
132
165
±10
±10
±15
0.22
0.14
0.14
0.16
1.0
0.95
A
±15
A
±5
±10
A
±10
A
±10
B
±10
267E 4001 337 _
1
_
2
734
330
D3
13
132
165
±10
±10
±15
0.18
0.10
0.10
0.12
0.5
0.45
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 4001 477 _
1
_
2
735
470
C3
19
188
235
±30
±20
±20
0.36
0.26
0.26
0.30
1.0
0.95
A
±20
A
±10
±3
A
±20
C
±20
C
±20
267E 4001 477 _
1
_
2
734
470
D3
19
188
235
±15
±10
±15
0.22
0.18
0.18
0.20
0.5
0.45
A
±15
A
±10
±10
A
±20
A
±10
B
±15
267E 4001 687 _
1
_
2
734
680
D3
27
272
340
±15
±10
±15
0.22
0.18
0.18
0.20
0.5
0.45
A
±15
A
±10
±10
A
±20
A
±10
B
±15
267E 6301 475 _
1
_
2
6.3
8
5
4.7
A
0.5
5
6.3
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.2
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 6301 685 _
1
_
2
6.8
A
0.5
5
6.3
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.2
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 6301 106 _
1
_
2
10
A
0.6
6
7.9
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.1
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 6301 156 _
1
_
2
533
15
A
0.9
9
12
±10
±10
±15
0.12
0.08
0.08
0.10
7.5
7.1
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 6301 156 _
1
_
2
15
B
0.9
9
12
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.8
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 6301 226 _
1
_
2
533
22
A
1.4
14
17
±10
±10
±15
0.12
0.08
0.08
0.10
7.5
7.1
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 6301 226 _
1
_
2
22
B
1.4
14
17
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.8
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 6301 336 _
1
_
2
533
33
A
2.1
21
26
±20
±20
±20
0.20
0.12
0.12
0.14
7.5
7.1
A
±10
A
±10
±3
A
±20
C
±10
C
±15
267E 6301 336 _
1
_
2
33
B
2.1
21
26
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.7
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 6301 476 _
1
_
2
534
47
A
3.0
30
37
±20
±20
±20
0.20
0.12
0.12
0.14
7.5
7.1
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 6301 476 _
1
_
2
533
47
B
3.0
30
37
±10
±10
±15
0.20
0.10
0.10
0.10
3.0
2.7
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 6301 476 _
1
_
2
720
47
C3
3.0
30
37
±10
±10
±15
0.08
0.06
0.06
0.08
0.6
0.55
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 6301 686 _
1
_
2
534
68
A
4.3
43
54
±20
±20
±20
0.20
0.12
0.12
0.14
7.5
7.1
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 6301 686 _
1
_
2
533
68
B
4.3
43
54
±20
±10
±15
0.18
0.10
0.10
0.12
3.0
2.7
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 6301 686 _
1
_
2
720
68
C3
4.3
43
54
±10
±10
±15
0.08
0.06
0.06
0.08
1.0
0.95
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 6301 107 _
1
_
2
535
100
A
6.3
126
157
±20
±20
±20
0.30
0.18
0.18
0.18
2.5
2.0
C
±20
C
±20
±3
C
±20
C
±20
C
±30
267E 6301 107 _
1
_
2
534
100
B
6.3
63
79
±20
±20
±20
0.22
0.12
0.12
0.14
5.0
4.7
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 6301 107 _
1
_
2
734
100
C3
6.3
63
79
±10
±10
±15
0.12
0.08
0.08
0.08
1.0
0.95
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 6301 107 _
1
_
2
720
100
D3
6.3
63
79
±10
±10
±15
0.10
0.08
0.08
0.08
0.5
0.45
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 6301 157 _
1
_
2
534
150
B
9.5
95
118
±20
±20
±20
0.30
0.20
0.20
0.22
3.0
2.7
C
±20
C
±20
±3
C
±20
C
±20
C
±30
267E 6301 157 _
1
_
2
734
150
C3
9.5
95
118
±10
±10
±15
0.18
0.10
0.10
0.12
1.0
0.95
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 6301 157 _
1
_
2
720
150
D3
9.5
95
118
±10
±10
±15
0.15
0.08
0.08
0.10
0.5
0.45
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 6301 227 _
1
_
2
735
220
C3
14
139
173
±10
±10
±15
0.22
0.14
0.14
0.16
1.0
0.95
A
±15
A
±5
±10
A
±10
A
±10
B
±10
267E 6301 227 _
1
_
2
734
220
D3
14
139
173
±10
±10
±15
0.15
0.08
0.08
0.10
0.5
0.45
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 6301 227 _
1
_
2
220
H
14
139
173
±10
±10
±15
0.15
0.08
0.08
0.10
0.31
0.27
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 6301 337 _
1
_
2
735
330
C3
21
208
260
±30
±20
±20
0.30
0.20
0.20
0.24
1.0
0.95
A
±20
A
±10
±3
A
±20
C
±20
C
±20
4
Catalog Number (
1
)(
2
)
UR
VDC
US
VDC
CR
µF
Case
code
Leakage current(DCL)
µA
Variation rate of
cap.
(ΔC/C)%
Dissipation factor
ESR
Ω
Surge
Resistance to soldering
heat
Resistance
to solvent
Temp. cycling
Damp heat
Life
85
125
20
85
125
-55
85
125
-55
20
85
125
10kHz
100kHz
DCL(
3
)
ΔC/C%
DCL(
3
)
ΔC/C%
ΔC/C%
DCL(
3
)
ΔC/C%
DCL(
3
)
ΔC/C%
DCL(
3
)
ΔC/C%
267E 6301 337 _
1
_
2
734
6.3
8
5
330
D3
21
208
260
±15
±10
±15
0.16
0.14
0.14
0.16
0.5
0.45
A
±15
A
±10
±10
A
±20
A
±10
B
±15
267E 6301 337 _
1
_
2
330
H
21
208
260
±10
±10
±15
0.15
0.08
0.08
0.10
0.3
0.27
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 6301 477 _
1
_
2
734
470
D3
30
296
370
±15
±10
±15
0.18
0.16
0.16
0.18
0.5
0.45
A
±15
A
±10
±10
A
±20
A
±10
B
±15
267E 6301 687 M _
2
734
680
D3
43
428
535
±15
±10
±15
0.24
0.20
0.20
0.24
0.5
0.45
A
±15
A
±10
±10
A
±20
A
±20
B
±20
267E 1002 335 _
1
_
2
10
13
8
3.3
A
0.5
5
6.3
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.2
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1002 475 _
1
_
2
4.7
A
0.5
5
6.3
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.2
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1002 685 _
1
_
2
6.8
A
0.7
7
8.5
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.1
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1002 106 _
1
_
2
533
10
A
1.0
10
13
±10
±10
±15
0.12
0.08
0.08
0.10
7.5
7.1
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1002 106 _
1
_
2
10
B
1.0
10
13
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.9
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1002 156 _
1
_
2
533
15
A
1.5
15
19
±20
±20
±20
0.20
0.12
0.12
0.14
7.5
7.1
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 1002 156 _
1
_
2
15
B
1.5
15
19
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.8
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1002 2 26 _
1
_
2
533
22
A
2.2
22
28
±20
±20
±20
0.20
0.12
0.12
0.14
7.5
7.1
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 1002 226 K _
2
22
B
2.2
22
28
±10
±10
±15
0.12
0.08
0.08
0.10
3.0
2.8
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 1002 226 M _
2
22
B
2.2
22
28
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.8
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1002 336 _
1
_
2
534
33
A
3.3
33
41
±20
±20
±20
0.20
0.14
0.14
0.16
7.5
7.1
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 1002 336 _
1
_
2
533
33
B
3.3
33
41
±10
±10
±15
0.12
0.08
0.08
0.10
3.0
2.7
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 1002 336 _
1
_
2
720
33
C3
3.3
33
41
±10
±10
±15
0.08
0.06
0.06
0.08
0.6
0.55
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1002 476 _
1
_
2
533
47
B
4.7
47
59
±10
±10
±15
0.15
0.08
0.08
0.10
3.0
2.7
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 1002 476 _
1
_
2
720
47
C3
4.7
47
59
±10
±10
±15
0.08
0.06
0.06
0.08
1.0
0.95
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1002 686 M _
2
534
68
B
6.8
68
85
±20
±20
±20
0.18
0.12
0.12
0.14
3.0
2.7
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 1002 686 _
1
_
2
734
68
C3
6.8
68
85
±10
±10
±15
0.12
0.10
0.10
0.12
1.0
0.95
A
±15
A
±5
±10
A
±10
A
±10
B
±10
267E 1002 686 _
1
_
2
720
68
D3
6.8
68
85
±10
±10
±15
0.08
0.06
0.06
0.08
0.5
0.45
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1002 107 _
1
_
2
534
100
B
10
100
125
±20
±20
±20
0.28
0.18
0.18
0.20
3.0
2.7
C
±20
C
±20
±3
C
±20
C
±20
C
±30
267E 1002 107 _
1
_
2
734
100
C3
10
100
125
±10
±10
±15
0.12
0.10
0.10
0.12
1.0
0.95
A
±15
A
±5
±10
A
±10
A
±10
B
±10
267E 1002 107 _
1
_
2
720
100
D3
10
100
130
±10
±10
±15
0.15
0.08
0.08
0.10
0.5
0.45
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1002 157 _
1
_
2
735
150
C3
15
150
188
±30
±20
±20
0.26
0.14
0.14
0.16
1.0
0.95
A
±20
A
±10
±3
A
±20
C
±20
C
±20
267E 1002 157 _
1
_
2
734
150
D3
15
150
188
±10
±10
±15
0.15
0.08
0.08
0.10
0.5
0.45
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1002 157 _
1
_
2
150
H
15
150
188
±10
±10
±15
0.15
0.08
0.08
0.10
0.31
0.27
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1002 227 _
1
_
2
735
220
C3
22
220
275
±30
±20
±20
0.26
0.14
0.14
0.16
1.0
0.95
A
±20
A
±10
±3
A
±20
C
±20
C
±20
267E 1002 227 _
1
_
2
734
220
D3
22
220
275
±15
±10
±15
0.15
0.10
0.10
0.12
0.5
0.45
A
±15
A
±10
±10
A
±20
A
±10
B
±15
267E 1002 227 _
1
_
2
220
H
22
220
275
±10
±10
±15
0.15
0.08
0.08
0.10
0.3
0.27
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1002 337 _
1
_
2
330
H
33
330
412
±10
±10
±15
0.15
0.10
0.10
0.12
0.3
0.27
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1002 477 _
1
_
2
470
H
47
470
588
±10
±10
±15
0.15
0.10
0.10
0.12
0.3
0.27
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1602 225 _
1
_
2
16
20
13
2.2
A
0.5
5
6.3
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.2
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1602 335 _
1
_
2
3.3
A
0.5
5
6.6
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.4
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1602 475 _
1
_
2
4.7
A
0.8
8
9.4
±10
±10
±15
0.12
0.08
0.08
0.10
7.5
7.1
A
±5
A
±5
±3
A
±5
A
±5
B
±10
5
Catalog Number (
1
)(
2
)
UR
VDC
US
VDC
CR
µF
Case
code
Leakage current(DCL)
µA
Variation rate of
cap.
(ΔC/C)%
Dissipation factor
ESR
Ω
Surge
Resistance to soldering
heat
Resistance
to solvent
Temp. cycling
Damp heat
Life
85
125
20
85
125
-55
85
125
-55
20
85
125
10kHz
100kHz
DCL(
3
)
ΔC/C%
DCL(
3
)
ΔC/C%
ΔC/C%
DCL(
3
)
ΔC/C%
DCL(
3
)
ΔC/C%
DCL(
3
)
ΔC/C%
267E 1602 685 _
1
_
2
533
16
20
13
6.8
A
1.1
11
14
±10
±10
±15
0.10
0.06
0.08
0.10
7.5
7.1
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1602 685 _
1
_
2
6.8
B
1.1
11
14
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.9
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1602 106 _
1
_
2
533
10
A
1.6
16
20
±20
±20
±20
0.14
0.10
0.10
0.12
7.5
7.1
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 1602 106 _
1
_
2
10
B
1.6
16
20
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.9
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1602 156 _
1
_
2
533
15
A
2.4
24
30
±20
±20
±20
0.18
0.12
0.12
0.14
7.5
7.1
A
±10
A
±10
±3
A
±20
C
±10
C
±20
267E 1602 156 _
1
_
2
15
B
2.4
24
30
±10
±10
±15
0.12
0.08
0.08
0.10
3.0
2.7
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 1602 226 _
1
_
2
533
22
B
3.5
35
44
±12
±10
±15
0.14
0.10
0.10
0.12
3.0
2.9
A
±15
A
±10
±3
A
±5
A
±5
B
±15
267E 1602 226 _
1
_
2
720
22
C3
3.5
35
44
±10
±10
±15
0.08
0.06
0.06
0.08
0.6
0.55
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1602 336 _
1
_
2
533
33
B
5.3
53
66
±10
±10
±15
0.14
0.10
0.10
0.12
2.0
1.9
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 1602 336 _
1
_
2
720
33
C3
5.3
53
66
±10
±10
±15
0.08
0.06
0.06
0.08
1.0
0.95
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1602 476 _
1
_
2
734
47
C3
7.5
75
94
±10
±10
±15
0.12
0.10
0.10
0.12
1.0
0.95
A
±15
A
±5
±10
A
±10
A
±10
B
±10
267E 1602 476 _
1
_
2
720
47
D3
7.5
75
94
±10
±10
±15
0.08
0.06
0.06
0.08
0.5
0.45
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1602 686 _
1
_
2
734
68
C3
11
109
136
±20
±15
±15
0.12
0.10
0.10
0.12
1.0
0.95
A
±15
A
±10
±3
A
±10
A
±15
B
±15
267E 1602 686 _
1
_
2
720
68
D3
11
109
136
±10
±10
±15
0.10
0.08
0.08
0.08
0.5
0.45
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 1602 107 _
1
_
2
734
100
D3
16
160
200
±15
±10
±15
0.12
0.10
0.10
0.12
0.5
0.45
A
±15
A
±10
±10
A
±20
A
±10
B
±15
267E 1602 107 _
1
_
2
100
H
16
160
200
±10
±10
±15
0.15
0.08
0.08
0.10
0.4
0.37
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2002 155 _
1
_
2
20
26
16
1.5
A
0.5
5
6.3
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.2
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2002 225 _
1
_
2
2.2
A
0.5
5
6.3
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.4
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2002 335 _
1
_
2
3.3
A
0.7
7
8.3
±10
±10
±15
0.12
0.08
0.08
0.10
7.5
7.1
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2002 475 _
1
_
2
533
4.7
A
0.9
9
12
±10
±10
±15
0.10
0.06
0.08
0.10
7.5
7.1
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2002 475 _
1
_
2
4.7
B
0.9
9
12
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.9
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2002 685 _
1
_
2
533
6.8
A
1.4
14
17
±15
±15
±15
0.14
0.10
0.10
0.10
5.0
4.7
A
±5
A
±5
±3
A
±15
A
±5
B
±15
267E 2002 685 _
1
_
2
6.8
B
1.4
14
17
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.9
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2002 106 _
1
_
2
10
B
2.0
20
25
±10
±10
±15
0.12
0.08
0.08
0.10
3.0
2.8
A
±5
A
±10
±3
A
±5
A
±5
B
±10
267E 2002 156 _
1
_
2
720
15
C3
3.0
30
38
±10
±10
±15
0.08
0.06
0.06
0.08
1.2
1.15
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2002 226 _
1
_
2
720
22
C3
4.4
44
55
±10
±10
±15
0.08
0.06
0.06
0.08
1.0
0.95
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2002 336 _
1
_
2
720
33
D3
6.6
66
83
±10
±10
±15
0.08
0.06
0.06
0.06
1.0
0.97
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2002 476 _
1
_
2
720
47
D3
9.4
94
117
±10
±10
±15
0.08
0.06
0.06
0.06
1.0
0.98
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2002 686 _
1
_
2
68
H
13.6
136
170
±10
±10
±15
0.08
0.06
0.06
0.08
0.4
0.37
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2002 107 _
1
_
2
100
H
20
200
250
±10
±10
±15
0.10
0.08
0.08
0.08
0.4
0.37
A
±5
A
±20
±3
A
±5
A
±5
B
±10
267E 2502 105 _
1
_
2
25
32
20
1.0
A
0.5
5
6.3
±10
±10
±15
0.06
0.04
0.04
0.06
7.5
7.4
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2502 155 _
1
_
2
1.5
A
0.5
5
6.3
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.4
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2502 225 _
1
_
2
2.2
A
0.6
6
6.9
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.4
A
±10
A
±5
±3
A
±10
C
±10
B
±10
267E 2502 335 _
1
_
2
533
3.3
A
0.8
8
10
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.4
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2502 335 _
1
_
2
3.3
B
0.8
8
10
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.9
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2502 475 _
1
_
2
533
4.7
A
1.2
12
15
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.4
A
±5
A
±5
±3
A
±5
A
±5
B
±10
6
Catalog Number (
1
)(
2
)
UR
VDC
US
VDC
CR
µF
Case
code
Leakage current(DCL)
µA
Variation rate of
cap.
(ΔC/C)%
Dissipation factor
ESR
Ω
Surge
Resistance to soldering
heat
Resistance
to solvent
Temp. cycling
Damp heat
Life
85
125
20
85
125
-55
85
125
-55
20
85
125
10kHz
100kHz
DCL(
3
)
ΔC/C%
DCL(
3
)
ΔC/C%
ΔC/C%
DCL(
3
)
ΔC/C%
DCL(
3
)
ΔC/C%
DCL(
3
)
ΔC/C%
267E 2502 475 _
1
_
2
25
32
20
4.7
B
1.2
12
15
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.9
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2502 685 _
1
_
2
6.8
B
1.7
17
21
±10
±10
±15
0.12
0.08
0.08
0.10
3.0
2.7
A
±20
A
±20
±3
A
±20
C
±20
C
±20
267E 2502 106 _
1
_
2
533
10
B
2.5
25
31
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.9
A
±10
A
±10
±3
A
±10
C
±10
B
±10
267E 2502 106 _
1
_
2
720
10
C3
2.5
25
31
±10
±10
±15
0.08
0.06
0.06
0.08
1.2
1.17
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2502 156 _
1
_
2
720
15
C3
3.7
38
48
±10
±10
±15
0.10
0.08
0.08
0.10
1.4
1.3
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2502 226 _
1
_
2
734
22
C3
5.5
55
69
±10
±10
±15
0.08
0.06
0.06
0.08
1.0
0.98
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2502 226 _
1
_
2
720
22
D3
5.5
55
69
±10
±10
±15
0.08
0.06
0.06
0.06
1.0
0.98
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2502 336 _
1
_
2
720
33
D3
8.3
83
104
±10
±10
±15
0.08
0.06
0.06
0.06
1.0
0.98
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 2502 107 _
1
_
2
100
H
25
250
312
±10
±10
±15
0.15
0.10
0.10
0.12
0.4
0.37
A
±5
A
±20
±3
A
±5
A
±5
B
±10
267E 3502 684 _
1
_
2
35
44
28
0.68
A
0.5
5
6.3
±10
±10
±15
0.06
0.04
0.04
0.06
7.5
7.4
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 3502 105 _
1
_
2
1.0
A
0.5
5
6.3
±10
±10
±15
0.06
0.04
0.04
0.06
7.5
7.4
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 3502 225 _
1
_
2
533
2.2
A
0.8
8
9.6
±10
±10
±15
0.08
0.06
0.06
0.08
7.5
7.4
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 3502 225 _
1
_
2
2.2
B
0.8
8
9.6
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.9
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 3502 335 _
1
_
2
3.3
B
1.2
12
14
±10
±10
±15
0.08
0.06
0.06
0.08
3.0
2.9
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 3502 685 _
1
_
2
720
6.8
C3
2.4
24
30
±10
±10
±15
0.08
0.06
0.06
0.08
1.2
1.17
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 3502 106 _
1
_
2
720
10
C3
3.5
35
44
±10
±10
±15
0.08
0.06
0.06
0.06
1.4
1.3
A
±5
A
±10
±3
A
±5
C
±10
B
±10
267E 3502 156 _
1
_
2
720
15
D3
5.3
53
66
±10
±10
±15
0.08
0.06
0.06
0.06
1.0
0.98
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 3502 226 _
1
_
2
720
22
D3
7.7
77
96
±10
±10
±15
0.08
0.06
0.06
0.06
1.0
0.98
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 5002 224 _
1
_
2
50
63
40
0.22
A
0.5
5
6.3
±10
±10
±15
0.06
0.04
0.04
0.06
7.5
7.5
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 5002 684 _
1
_
2
0.68
B
0.5
5
6.3
±10
±10
±15
0.06
0.04
0.04
0.06
3.0
3.0
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 5002 225 _
1
_
2
720
2.2
C3
1.1
11
14
±10
±10
±15
0.08
0.06
0.06
0.08
1.2
1.2
A
±5
A
±5
±3
A
±5
A
±5
B
±10
267E 5002 475 _
1
_
2
720
4.7
D3
2.4
24
29
±10
±10
±15
0.08
0.06
0.06
0.08
1.0
1.0
A
±5
A
±5
±3
A
±5
A
±5
B
±10
* UR = Rated Voltage US = Surge Voltage CR = Capacitance
Note1 : For Capacitance Tolerance, insert “K” or “M” into _1.
Note2 : For Reeled Package, insert “R”, “L”, “N” or “P” into _2.
Note3 : *DCL code : A=Shall not exceed the value of initial specification., B=Shall not exceed 1.25 times the value of initial specification.,
C=Shall not exceed 2 times the value of initial specification.
7
No.
Item
Performance
Test method
1
Leakage Current (µA)
Shall not exceed 0.01 CV or 0.5 whichever is greater.
JIS C 5101-1, 4.9
Applied Voltage :
Rated Voltage for 5 min.
Temperature : 20°C
2
Capacitance (µF)
Shall be within tolerance of the nominal value specified.
JIS C 5101-1, 4.7
Frequency : 120 Hz± 20%
Voltage : 0.5Vrms+1.5 ~2VDC
Temperature : 20°C
3
Dissipation Factor
Shall not exceed the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
JIS C 5101-1, 4.8
Frequency : 120 Hz± 20%
Voltage : 0.5Vrms+1.5 ~2VDC
Temperature : 20°C
4
ESR
(Equivalent series resistance)
Shall not exceed the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Frequency : 10 kHz or 100kHz
Temperature : 20°C
5
Characteristics
at High and LowTemperature
JIS C 5101-1, 4.29
Step1
Leakage
Current
Capacitance
Dissipation
Factor
Shall not exceed the value in No.1.
Shall be within the specified tolerance.
Shall not exceed the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Measuring temperature : 20 ± 2°C
Step2
Capacitance
Change
Dissipation
Factor
Shall be within the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Shall not exceed the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Measuring temperature : -55±3 °C
Step3
Leakage
Current
Capacitance
Change
Dissipation
Factor
Shall not exceed the value in No.1.
Shall be within ± 2% of the value at Step 1.
Shall not exceed the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Measuring temperature : 20 ± 2°C
Step4
Leakage
Current
Capacitance
Change
Dissipation
Factor
Shall not exceed the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Shall be within the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Shall not exceed the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Measuring temperature : 85±2°C
Step5
Leakage
Current
Capacitance
Change
Dissipation
Factor
Shall not exceed the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Shall be within the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Shall not exceed the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Measuring temperature : 125±C
Measuring voltage :
Derated voltage at 125°C
Step6
Leakage
Current
Capacitance
Change
Dissipation
Factor
Shall not exceed the value in No.1.
Shall be within ± 2% of the value at Step 1.
Shall not exceed the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Measuring temperature : 20 ± 2°C
6
Surge
Leakage
Current
Capacitance
Change
Dissipation
Factor
Appearance
Shall not exceed the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Shall be within the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Shall not exceed the value in No.3.
There shall be no evidence of mechanical damage.
JIS C 5101-1, 4.26
Test temperature and applied
voltage : To each half of specimens
85 ± 2°C,
125 ± 2°C
Applied Voltage :DC surge voltage
Series protective resistance :
1000 Ω
Discharge resistance : 1000 Ω
7
Shear Test
No exfoliation between lead terminal and board.
JIS C 5101-1, 4.34
Capacitors mounted under
conditions JIS C 5101-1, 4.33 are
used as specimens.
Soldering : Indirect heating
Temperature : 240 ± 10°C
Duration : 10s or less
Applied pressure : 5N
Duration : 10 ± 1 s
8
Substrate
Bending Test
Capacitance
Appearance
Initial value to remain steady during measurement.
There shall be no evidence of mechanical damage.
JIS C 5101-1, 4.35
Bending : 3 mm
Duration:5s
9
Vibration
Capacitance
Appearance
Initial value to remain steady during measurement.
There shall be no evidence of mechanical damage.
JIS C 5101-1, 4.17
Frequency range :
10 ~ 55 Hz Swing width : 1.5 mm
Vibration direction :
3 directions with mutually
right-angled
Duration :
2 hours in each of these mutually
perpendicular directions
(total 6 hours)
Mounting :
Solder terminal to the printed board
PERFORMANCE
8
No.
Item
Performance
Test method
9
Vibration
Capacitance
Appearance
Initial value to remain steady during measurement.
There shall be no evidence of mechanical damage.
JIS C 5101-1, 4.17
Frequency range :
10 ~ 55 Hz Swing width : 1.5 mm
Vibration direction :
3 directions with mutually
right-angled
Duration :
2 hours in each of these mutually
perpendicular directions
(total 6 hours)
Mounting :
Solder terminal to the printed board
10
Shock
There shall be no intermittent contact of 0.5 ms or
greater, short, or open. Nor shall there be any spark
discharge, insulation breakdown, or evidence of
mechanical damage.
JIS C 5101-1, 4.19
Peak acceleration : 490 m/s2
Duration : 11 ms
Wave form : Half-sine
11
Solderability
Shall be covered to over 3/4 of terminal surface by new
soldering.
JIS C 5101-1, 4.15
Solder temperature : 230 ± 5°C
Dipping time : 3 to 5 s
Dipping depth :
Terminal shall be dipped into melted
solder.
12
Resistance
to
Soldering
Heat
Leakage
Current
Capacitance
Change
Dissipation
Factor
Appearance
Shall not exceed the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Shall be within the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Shall not exceed the value in No.3.
There shall be no evidence of mechanical damage.
JIS C 5101-1, 4.14
One of the following methods
(a) Complete dipping method
Solder temperature: 260 ± 5°C
Dipping time: 10 ± 1 s
(b) Terminal dipping method
Solder temperature: 260 ± 5°C
Dipping time: 10 ± 1 s
13
Component
solvent
resistance
Leakage
Current
Capacitance
Change
Dissipation
Factor
Shall not exceed the value in No.1.
Shall be within the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Shall not exceed the value in No.3.
JIS C 5101-1, 4.31
Temperature : 23 ± 5°C
Dipping time : 5 ± 0.5 min.
Conditioning : JIS C 0052 method
2
Solvent : 2-propanol
(Isopropyl alcohol)
14
Solvent
resistance
of marking
Visual
examination
After the test the marking shall be legible.
JIS C 5101-1, 4.32
Temperature : 23 ± 5°C
Dipping time : 5 ± 0.5 min.
Conditioning :
JIS C 0052 method 1
Solvent : 2-propanol
(Isopropyl alcohol)
Rubbing material : cotton wool
15
Rapid
Change of
Temperature
Leakage
Current
Capacitance
Change
Dissipation
Factor
Appearance
Shall not exceed the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Shall be within the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Shall not exceed the value in No.3.
There shall be no evidence of mechanical damage.
JIS C 5101-1, 4.16
Step 1 : -55 ± 3°C, 30 ± 3 min.
Step 2 : 25 °C, 3 min. max.
Step 3 : 125 ± 2°C, 30 ± 3 min.
Step 4 : 25 °C, 3 min. max.
Number of cycles : 5
16
Damp heat,
Steady state
Leakage
Current
Capacitance
Change
Dissipation
Factor
Appearance
Shall not exceed the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Shall be within the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Shall not exceed the value in No.3.
There shall be no evidence of mechanical damage.
JIS C 5101-1, 4.22
Temperature : 40 ± 2°C
Moisture : 90 ~ 95%RH
Duration : 500 h
17
Endurance
Leakage
Current
Capacitance
Change
Dissipation
Factor
Appearance
Shall not exceed the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Shall be within the values shown in CATALOG
NUMBERS AND RATING OF EXTENDED PRODUCTS.
Shall not exceed the value in No.3.
There shall be no evidence of mechanical damage.
JIS C 5101-1, 4.23
Test temperature and applied
voltage :
85 ± 2°C and rated voltage or
125 ± 3°C and 2/3 × rated voltage
Duration : 2000 h
Power supply impedance :
3 Ω or less
+10
-5
+10
-5
+24
0
+72
0
9
267E 35VDC-1mF A-case , Sample:5pcs
Measuring temperature : room temperature
TEMPERATURE CHARACTERISTICS
0.001
0.01
0.1
1
10
100
1K
10K
100
1K
10K
100K
1M
10M
E.S.R.(Ω)
Imp.(Ω)
Frequency [Hz
Impedance & ESR(Ω)
267E 35VDC-1mF A-case , Sample:12pcs.
FREQUENCY CHARACTERISTICS
-8
-6
-4
-2
0
2
4
6
8
10
12
-60 -40 -20 0 20 40 60 80 100 120
0.00
0.02
0.04
0.06
0.08
-60 -40 -20 0 20 40 60 80 100 120
0.01
0.1
1
10
100
1000
020 40 60 80 100 120
MAX
mean
MIN
Temperature()
Temperature()
Temperature()
Dissipation factor
Capacitance Change
(%)
10
DAMP HEAT, STEADY STATE 40, 95%RH
ENDURANCE 85, RATED VOLTAGE
267E 35VDC-1mF A-case Sample: 50pcs.
267E 35VDC-1mF A-case Sample: 50pcs.
◆  ◆
●  ●
▲  ▲
Max.
mean
Min.
◆  ◆
●  ●
▲  ▲
Max.
mean
Min.
0.001
0.01
0.1
1
10
100
110 100 1000 10000
-25
-20
-15
-10
-5
0
5
10
0
0.01
0.02
0.03
0.04
0.05
Capacitance
hange (%)
Leakage current (μA)
Dissipation
factor
INITIAL
VALUE
Time (Hours)
DIP260
10sec
0.001
0.01
0.1
1
10
100
110 100 1000 10000
-25
-20
-15
-10
-5
0
5
10
0
0.01
0.02
0.03
0.04
0.05
Capacitance
hange (%)
Leakage current (μA)
Dissipation
factor
INITIAL
VALUE
DIP260
10sec
Time(Hours)
11
Application Notes for Tantalum Solid Electrolytic Capacitor
1. Operating Voltage
Tantalum Solid Electrolytic Capacitor shall be operated at the rated voltage or lower.
Rated voltage: The “rated voltage” refers to the maximum DC voltage that is allowed to be continuously applied between the capacitor
terminals at the rated temperature.
Surge voltage: The “surge voltage” refers to the voltage that is allowed to be instantaneously applied to the capacitor at the rated
temperature or the maximum working temperature. The capacitor shall withstand the voltage when a 30-second cycle of application of
the voltage through a 1000 Ω series resistance is repeated 1000 times in 6-minute periods.
When designing the circuit, the equipment’s required reliability must be considered and appropriate voltage derating must be
performed.
2. Application that contain AC Voltage
Special attention to the following 3 items.
(1) The sum of the DC bias voltage and the positive peak value of the AC voltage should not exceed the rated voltage.
(2) Reverse voltage should not exceed the allowable values of the negative peak AC voltage.
(3) Ripple current should not exceed the allowable values.
3. Reverse Voltage
Tantalum solid electrolytic capacitor is polarity. Please do not impress reverse voltage. As well, please confirm the potential of the tester
beforehand when both ends of the capacitor are checked with the tester etc.
4. Permissible Ripple Current
The permissible ripple current and voltage at about 100 kHz or higher can be determined by the following formula from the permissible
power loss (Pmax value)shown in Table 1 and the specified ESR value. However, when the expected
operating temperature is higher than room temperature, determine the permissible values multiplying the Pmax value by the specified
multiplier (Table 2). For the permissible values at different frequencies, consult our Sales Department.
P=I 2×ESR or P=
2
2
ZESRE
Permissible ripple current Imax=
ESR
Pmax
(Arms)
Permissible ripple voltage Emax=
ESR
maxP
× Z
= Imax× Z (Vrms)
Imax : Permissible ripple current at regulated frequency (Arms : RMS value)
Emax : Permissible ripple voltage at regulated frequency (Vrms : RMS value)
Pmax : Permissible power loss (W)
ESR : Specified ESR value at regulated frequency (Ω)
Z : Impedance at regulated frequency (Ω)
Table 1 Permissible power loss Table 2 Pmax multiplier at each operating temperature
Note: Above values are measured at 0.8t glass epoxy board
mounting in free air and may be changed depending on
the kind of board, packing density, and air convection
condition. Please consult us if calculated power loss value
is different from above list of P max value.
5. Application on low-impedance circuit
The failure rate of low impedance circuit at 0.1Ω/V is about five times greater than that of a 1Ω/V circuit. To curtail this higher failure
rate, tantalum capacitors used in low impedance circuits, such as filters for power supplies, particularly switching power supplies, or for
noise by-passing, require that operating voltage be derated to less than half of the rated voltage. Actually, less than 1/3 of the rated
voltage is recommended.
6. Non Polar Application(BACK TO BACK)
Tantalum capacitors can be used as a non-polar unit if two capacitors are connected “BACK-TO-BACK” when reserve voltage is
applied at a more than permissible value, or in a purely AC circuit. The two capacitors should both be of the same rated voltage and
capacitance tolerance, and they should both be twice the required capacitance value.
Ripple Voltage: Permissible Ripple Voltage shall not exceed the value allowed for either
C1 or C2 (This will be the same, as the capacitors should be identical.)
Capacitance: (C1 × C2) / (C1 + C2)
Leakage Current: If terminal A is (+), the Leakage Current will be equal to C1’s Leakage Current.
If terminal B is (+), the Leakage Current will be equal to C2’s Leakage Current.
7. Soldering
7.1. Preheating
To obtain optimal reliability and solderability conditions, capacitors should be pre-heated at 130 to 200 °C for approximately 60 to 120
seconds.
7.2. Soldering
The body of the capacitor shall not exceed 260 °C during soldering.
(1) Reflow Soldering
Reflow soldering is a process in which the capacitors are mounted on a printed board with solder paste. There are two methods of
Reflow Soldering: Direct and Atmospheric Heat.
· Direct Heat (Hot plate)
During the Direct Heat method, the capacitor has been positioned on a printed board, which is then placed upon a hot plate.
The capacitor maintains a lower temperature than the substrate, which in turn stays at a lower temperature than the hot plate.
· Atmospheric Heat
+ - - +
●●●
AC1 C2 B
Operating temperature () Multiplier
25 1.0
55 0.9
85 0.8
125 0.4
Case size
PmaxW
A 0.045
B 0.050
C3 0.065
D3 0.085
H 0.100
12
a) VPS (Vapor Phase Soldering)
During VPS,the substrate is heated by an inert liquid with a high boiling point. The temperature of the capacitor’s body and the
temperature of the substrate are about the same as the atmosphere. This temperature should be below 240°C.
b) Near and Far IR Ray
Due to the heat absorption of the capacitor’s body, the internal temperature of the capacitors may be 20 ~ 30°C higher than the
setting temperature and may exceed 260°C.
Temperature control is crucial in maintaining a temperature of 260 °C or lower.
c) Convention Oven
An infrared ray is the main source of heat in this process. The temperature of the substrate and the capacitors can be maintained
at a similar level by the circulation of heated air, or an inert gas.
(2) Soldering with a Soldering Iron
Soldering with a soldering iron cannot be recommended due to the lack of consistency in maintaining temperatures and process
times. If this method should be necessary, the iron should never touch the capacitor’s terminals, and the temperature of the
soldering iron should never exceed 350°C. The application of the iron should not exceed 5 seconds.
(3) Please consult us for other methods.
8. Cleaning
Cleaning by organic solvent may damage capacitor’s appearance and performance.However, our capacitors are not effected even
when soaked at 20 ~ 30°C 2-propanol for 5 minutes. When introducing new cleaning methods or changing the cleaning term, please
consult us.
9. Protective Resin Coating
After components are assembled to substrate, a protective resin coating is sometimes applied. As this resin coating cures, it gives
mechanical and thermal stress to Tantalum capacitors. This stress can cause damage to the capacitors, which affects their reliability.
Before using a resin coating, proper research must be done in regards to the material and process to insure that excessive stress will
not be applied to capacitors and other components.
10. Vibration
Approximately 300 G shall be applied to a capacitor, when dropped from 1 meter to a concrete floor.
Although capacitors are made to withstand this drop test, stress from shock due to falling or striking does cause damage to the
capacitors and increases failure rates. Do not subject capacitors to this type of mechanical stress.
11. Ultrasonic cleaning
Matsuo does not recommend Ultrasonic cleaning. This may cause damage to the capacitors, and may even cause broken terminals. If
the Ultrasonic cleaning process will be used, please note the following:
(1)The solvent should not be boiled. (Lower the ultrasonic wave output or use solvent with The high boiling point.)
(2)The recommended wattage is less than 0.5 watts per cm2.
(3)The cleaning time should be kept to a minimum. Also, samples must be swang in the solvlent. Please consult us.
12. Additional Notes
· When more than one capacitor is connected in series, a resistor that can distribute the voltage equally to the capacitors shall be
connected in parallel.
· The capacitor cases shall not be cut even if the mounting space is insufficient.
· During a customers aging process, voltage should remain under the rated voltage at all times.
· Capacitors should never be touched or manipulated while operating.
· Capacitors are not meant to be dismantled.
· When testing capacitors, please examine the power source before conducting test to insure the tester’s polarity and applied voltage.
· In the event of a capacitor burning, smoking, or emitting an offensive smell during operation, please turn the circuit “off” and keep
hands and face away from the burning capacitor.
· If a capacitor be electrical shorted, it becomes hot, and the capacitor element may ignite.
In this case, the printed board may be burnt out.
· Capacitors should be stored at room temperature under low humidity. Capacitors should never be stored under direct sunlight, and
should be stored in an environment containing dust.
· If the capacitors will be operated in a humid environment, they should be sealed with a compound under proper conditions.
· Capacitors should not be stored or operated in environments containing acids, alkalis or active gasses.
· When capacitors are disposed of as “scrap” or waste, they should be treated as Industria Waste since they contain various metals and
polymers.
· Capacitors submitted as samples should not be used for production purposes.
These application notes are prepared based on “Guideline of notabilia for fixed tantalum electrolytic capacitors with solid electrolyte for
use in electronic equipment” (EIAJ RCR-2386) issued by Japan Electronics and Information Technology Industries Association (JEITA).
For the details of the instructions (explanation, reasons and concrete examples), please refer to this guideline, or consult our Sales
Department.
Temperature of
Boards Surface
Reflow
Cooling
Pre-heat
T2
T1
T3
A1A2
Time
Temperature Time
T1=130℃~200 A1= 60120sec.
T2=220℃~230 A260sec.
T3=260 10 sec. or less than 10
Number of times2 times max..
Specifications on this catalog are subject to change without prior notice. Please inquire of our Sales Department
to confirm specifications prior to use.
Please feel free to ask our Sales Department for more information on Tantalum Solid Electrolytic
Capacitor .
Overseas Sales Dep. 5-3,3-Chome,Sennari-cho,Toyonaka-shi,Osaka 561-8558,Japan Tel: 06-6332-0883 Fax : 06-6332-0920
Head office 5-3,3-Chome,Sennari-cho,Toyonaka-shi,Osaka 561-8558,Japan Tel : 06-6332-0871 Fax : 06-6331-1386
URL http://www.ncc-matsuo.co.jp/