Optical Input
Number of Fiber Optic Inputs: 1
Maximum Input: 0 dBm
Minimum Input: –20 dBm
Wavelength: 1250 to 1600 nm
Input Line Rate: 2.125 Gbps
RF Output
Number of Analog Outputs: 2
Passband: 5-48 MHz
Output RF level1: –31 dBmV/Hz
Impedance: 75 Ω
Flatness2:
10-48 MHz: ±0.5 dB or less
Optical Interface
Connector Type:
RDR2000-AS: SC/APC
RDR2000-US: SC/UPC
User Interface
RF test point connectors: Type “F”
Total number of RF test point connections: 2 accessible
from the front
RF output test point: –20 ±1.0 dB
Optical level test point: 1 V/mW
DC power: Green LED
Optical power alarm: Red LED
Element Monitoring System - NETWatch™/HEM
Optical power alarm — monitor
Optical power — monitor
Power Requirements
Maximum power: 12.5 W
Environmental
Operating temperature range: –20° to +65°C
Storage temperature range: –40° to +85°C
Physical
Dimensions: 12.5”L x 0.8”W x 4.1”H
Mounting: Plug-in card for the HTR2000D (or above) platform
Notes:
1. For a digitized Gaussian noise signal at 0 to -20 dBm of received average optical power.
2. When used in conjunction with the Harmonic family of digital transmitters.
RDR 2000
Specifications
Copyright 2000 Harmonic Inc. Harmonic continues to improve and enhance all
product designs. Specifications are subject to change without notice. Harmonic
and logo design, eXchange, MAXLink, METROLink, NETWatch, PWRBlazer,
TRANsend, and “Redefining the Network” are trademarks of Harmonic Inc.
YAGLink and PWRLink are registered trademarks of Harmonic Inc. All other
names are trademarks or registered trademarks of their respective owners. 2203-01 1K 02/00
Harmonic Inc.
549 Baltic Way
Sunnyvale, CA 94089
Tel. 408-542-2500
Tel. 800-730-4099
Fax 408-542-2510