Integrated Pressure Transducer
IPT
Honeywell’s Integrated Pressure Transducer (IPT) provides high accuracy pressure data in an industry standard SPI
digital format. The core of the IPT is a proven Honeywell silicon piezoresistive pressure sensor with both pressure and
temperature sensitive elements. The IPT is small and lightweight and can be easily integrated by the user into a wide
variety of applications that require high performance in a small package. Applying the coefficients stored in the on-board
EEPROM to the normalized IPT pressure and temperature output yields highly accurate and stable pressure readings
over the -40 to 85°C compensated temperature range.
FEATURES AND BENEFITS
High Accuracy Over a Wide
Temperature Range
From -40 to 85 C
0.04% FS Total Error Band
(absolute pressure),
to 0.10% FS Total Error Band
(gauge/ differential pressure) (1)
Stored Correction Coefficients in EEPROM Ready to use;
No additional pressure and temperature calibration necessary.
Simplifies System Design No additional signal compensation
needed to achieve a highly accurate pressure reading.
Digital SPI Output
Industry Standard Interface Ready communication between
a µController/µProcessor and the IPT.
Small and Versatile
Volume ~ 1 in3 (16 cm3)
Lightweight Less than 10 grams.
Media Interface Handles most dry gas media.
APPLICATIONS:
Air Data Computers
Altimeters
Cabin Air Pressure
Engine Test Systems
Flight Test Systems
Meteorology
Flow and Pressure Calibrators
Instrumentation and Analytical Equipment
Research and Development
Excellent
Pressure
Stability
0.04% FS Total
Error Band, -40 to
85ºC, Absolute
ISO-9001
ISO-14001
±0.10% FS Total
Error Band, -40 to
85ºC, Gauge/
Differential
IPT
DIMENSIONS
SPECIFICATIONS ORDERING INFORMATION
CONNECTOR
Find out more
For more information on Honeywell’s Precision Pressure Transducers visit us online at www.honeywell.com/pressuresensing or contact
us at 1-800-323-8295 or 763-954-2474. Customer Service Email: ps.customer.support@honeywell.com.
Honeywell reserves the right to make changes to improve reliability, function or design. Honeywell does not assume any liability arising out of the application or use of any product or circuit described
herein; neither does it convey any license under its patent rights nor the rights of others. Covered by one or more of the following US Patents: 4,918,992 and 4,788,521.
IPT Integrated Pressure Transducer
IPT
FULL SCALE PRESSURE RANGE
Absolute
Gauge
Differential
0001
N/A
1 PSIG(1)
1 PSID
0002
N/A
2 PSIG
2 PSID
0005
N/A
5 PSIG
5 PSID
0010
N/A
10 PSIG
10 PSID
0020
20 PSIA
20 PSIG
20 PSID
0050
50 PSIA
N/A
N/A
TYPE
P1 Pressure
P2 Pressure
A
Absolute
0 (vacuum) to FS
N/A
G
Gauge
Reference to FS
Reference
D
Differential
+FS to FS rel. to P2
+FS to FS rel. to P1
DIGITAL INTERFACE VOLTAGE
33
3.3 volts
POWER SUPPLY
R Regulated, 4-12VDC
Example:
OPTIONS
A Demonstration Kit(4)
IPT
0020
A
33
R
-A
Performance Specifications (1)
Total Error Band: (from -40 to 85ºC)
±0.04%FS absolute
±0.10%FS gauge, differential
±0.20%FS 1 psi gauge
Temperature Range:
Operating -40 to 85ºC (-40 to 185ºF)
Storage: -55 to 125ºC (-67 to 257ºF)
Long Term Stability:
0.025% FS max per year
Mechanical Specifications
Pressure Ranges and Type:
See Ordering Information at right
Pressure Units: PSI(2)
Media Compatibility: Suitable for non-condensing,
non-corrosive, and non-combustible gases.
Weight(3): ~8.0 grams (absolute)
~9.7 grams (gauge, differential)
Electrical Specifications
Output:
24-bit pressure value
16-bit temperature value
256 x 8 EEPROM configuration
Power Requirements:
Supply Voltage: 4 to 12 VDC
Current Consumption:
6 mA typical, 7.5 mA max
Interface: 3.3V SPI (mode 1,1) SCLK 5 Mhz
Update Rate: 166 samples/second
Environmental Features
Overpressure: 3x FS
Burst Pressure: 3x FS
Mechanical Shock: DO-160E Section 7.0,
Category A, Figure 7.2, Operational Standard
Thermal Shock: Storage Temperature Cycling per
JESD22-104, Section 5.0: -55ºC to +125ºC
Vibration: DO-160E Section 8, Category H,
Aircraft Type 2, Aircraft Zones 1 & 2
RoHS Compliant (2002/05/EC): Yes
Honeywell Aerospace
Honeywell International Inc.
12001 Highway 55
Plymouth, MN 55441
www.honeywell.com
ADS-14184
December 2010
©2010 Honeywell International Inc.
(1) Total Error is the sum of worst case linearity, repeatability, hysteresis, thermal effects, and calibration errors
over the operating temperature range. Accuracy is only achieved after applying the correction coefficients and
algorithm as shown in section 3.2. of Product Specification (FS = Full Scale). For total error calculations of
differential units, “Full Scale” is the pressure difference between the minimum and maximum pressures. For
example, full scale for a 1 psid PPT is 2 psi (-1 to +1 psi). Pressure range 1psi gauge has total error of ±0.20%
FS. (2) After applying the correction coefficients stored in EEPROM, the resultant pressure reading is
expressed in PSI (pounds per square inch). (3) Not including mounting hardware. (4) Demonstration kit includes
RS-232 Cable, Demo Board, AC adapter, MS Windows Software, and User’s Manual.