TECHNICAL DATA DETECTION DIAGRAMS
Power supply: ............................................... 10 ... 30 Vdc, reverse polarity protection
Consumption: ............................................... 80 mA max.
Light emission: ............................................. red 630 nm / green 526 nm LED
white LED (TLµ-4/5xx vers.)
Spot dimension: ........................................... 1.5 x 5 mm (9 mm lens)
Ø 3 mm (9 lens - circular)
2 x 7 mm (18 mm lens)
Operating distance: ......................................6 ... 12 mm (9 mm lens)
14 ... 22 mm (18 mm lens)
22 ... 34 mm (28 mm lens)
40 ... 60 mm (50 mm lens)
Operating distance with fibre-optics: ......... 0 ... 3 mm proximity
0... 10 mm through beam
Depth of field: ............................................... ±3 mm (9 mm lens)
±4 mm (18 mm lens)
±6 mm (28 mm lens)
±10 mm (50 mm lens)
Setting: .......................................................... Teach-in with 2 push-buttons
Remote with 2 wires
dynamic Auto-Set (vers.TLµ-417/517)
Indicators: ..................................................... red OUTPUT LED
green POWER LED (vers.TLµ-417/517)
green READY LED
Output type: .................................................. NPN or PNP, Rpull-down/up 10 kΩ
Saturation voltage: ....................................... 1 V max. (NPN vers.)
2 V max. (PNP vers.)
Output current: ............................................. 200 mA max., short-circuit protection
Response time: .............................................50 µs max., 25 µs max. (TLµ-4/5xx vers.)
Switching frequency: ................................... 10 kHz max., 20 kHz max. (TLµ-4/5xx vers.)
Operating mode: .......................................... automatic dark/light selection
Analog output range: ................................... 0 ... 5.5 Vdc (2 Vdc on white 90%)
2.2 kΩoutput resistance
Timing function: ........................................... 20 ms minimum output ON
Connection: .................................................. M12 4-pole connector
3m Ø 6.1 mm shielded cable
Electrical protection: ....................................class 1
Mechanical protection: ................................ IP67
Housing material: ......................................... ZAMA
Lens material: ............................................... glass
Fibre-optic material: ..................................... fibre in glass / sheath in metal
fibre in PMMA / sheath in PE (OF-30)
Weight: .......................................................... 310 g max. (connector vers.)
450 g max. (cable vers.)
Operating temperature: ............................... -10 ... +55°C
Storage temperature: ................................... -25 ... +70°C
Fibre operating temperature: ...................... -30 ... +150°C (glass OF vers.)
-30 ... +60°C (OF-30)
Reference standard: .....................................EN 60947-5-2
Certifications: ...............................................
The operating distances indicate the typical detection distance.
22 mm lens
9 mm lens
28 mm lens
50 mm lens
Proximity fibre-optics
Through beam fibre-optics
18 mm lens
The detection diagrams indicate the typical
operating distance.
UNI EN ISO9001
UNI EN ISO14000
II3D