The Series 3700A offers scalable, instrument grade switching and multi-channel measurement solutions that are optimized for automated testing of electronic products and components. The Series 3700A includes four versions of the Model 3706A system switch mainframe along with a growing family of plug-in switch and control cards. When the Model 3706A mainframe is ordered with the high performance multimeter, you receive a tightly integrated switch and measurement system that can meet the demanding application requirements in a functional test system or provide the flexibility needed in stand-alone data acquisition and measurement applications. * Six-slot system switch mainframe with optional high performance multimeter * Multi-processor architecture optimized for high throughput scanning and pattern switching applications * Remote PC control via Ethernet, USB, and GPIB interfaces * Up to 576 two-wire or 720 onewire multiplexer channels in one mainframe * Up to 2,688 one-pole matrix crosspoints in one mainframe * Embedded Test Script Processor (TSP(R)) offering unparalleled system automation, throughput, and flexibility SWITCHING AND CONTROL System Switch/Multimeter and Plug-In Cards * TSP-Link Technology master/ slave connection provides easy system expansion and seamless connection to Series 2600 and 2600B SourceMeter(R) SMU instruments * Capable of over 14,000 readings per second to memory with optional high performance multimeter * LXI interface with embedded Web browser interface for test setup, maintenance, and basic application control Maximizes System Control and Flexibility To provide users with greater versatility when designing test systems, the Series 3700A mainframes are equipped with many standard features. For example, easy connectivity is supported with three remote interfaces: LXI/Ethernet, General Purpose Interface Bus (GPIB), and Universal Serial Bus (USB). Fourteen digital I/O lines are also included, which are programmable and can be used to control external devices such as component handlers or other instruments. Additionally, system control can be greatly enhanced by using our Test Script Processor (TSP) technology. This technology provides "smart" instruments with the ability to perform distributed processing and control at the instrument level versus a central PC. High Quality Switching at a Value Price The Series 3700A builds upon Keithley's tradition of producing innovative, high quality, precise signal switching. This series offers a growing family of high density and general purpose plug-in cards that accommodates a broad range of signals at very competitive pricing. The Series 3700A supports applica tions as diverse as design validation, accelerated stress testing, data acquisition, and functional testing. Model 3706A Mainframe The Series 3700A includes the base Model 3706A system switch/multimeter mainframe with three options for added flexibility. This mainframe contains six slots for plug-in cards in a compact 2U high (3.5 inches/89mm) enclosure that easily accommodates the needs of medium to high channel count applications. When fully loaded, a mainframe can support up to 576 two-wire multiplexer channels or 2,688 one-pole matrix crosspoints for unrivaled density and economical per channel costs. High Performance, 71/2-digit Multimeter (DMM) The high performance multimeter option provides up to 71/2-digit measurements, offering 26-bit resolution to support your ever-increasing test accuracy requirements. This flexible resolution supplies a DC reading rate from >14,000 readings/second at 31/2 digits to 60 readings/second at 71/2 digits to accommodate a greater span of applications. Single Channel Reading Rates The multimeter does not use a card slot, so 4 Wire DCV/ you maintain all six slots in your mainframe. Ohms NPLC 2 Wire Ohms In addition, the multimeter is wired to the 60 29 1.0 mainframe's analog backplane, ensuring a high 295 120 0.2 quality signal path from each card channel to 935 285 0.06 the multimeter. 0.006 6,200 580 The multimeter supports 13 built-in measure14,100 650 0.0005 ment functions, including: DCV, ACV, DCI, ACI, frequency, period, two-wire ohms, four-wire ohms, three-wire RTD temperature, four-wire RTD temperature, thermocouple temperature, thermistor temperature, and continuity. In addition, the multimeter offers extended low ohms (1W) and low current (10A) ranges. In-rack calibration is supported, which reduces both maintenance and calibration time. 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence System switch with high performance multimeter System switch with high performance multimeter Series 3700A System Switch/Multimeter and Plug-In Cards Mainframes 3706ASix-slot system switch with high performance DMM 3706A-NFP Six-slot system switch with high performance DMM, without front panel display and keypad 3706A-SSix-slot system switch 3706A-SNFP Six-slot system switch, without front panel display and keypad Plug-in Cards 3720 Dual 1x30 multiplexer card (auto CJC when used with 3720-ST) 3721 Dual 1x20 multiplexer card (auto CJC when used with 3721-ST) 3722 Dual 1x48, high density, multiplexer card 3723 Dual 1x30, high speed, reed relay multiplexer card 3724 Dual 1x30 FET multiplexer card 3730 6x16, high density, matrix card 3731 6x16 high speed, reed relay matrix card 3732 Quad 4x28, ultrahigh density, reed relay matrix card 3740 32 channel isolated switch card Multifunction 3750 control card Measurement Capability 1p 1 1n 1m 1 1k DC Voltage AC Voltage DC Current AC Current Frequency 1M 1G 500kHz Period Resistance (2-Wire) Resistance (4-Wire) 2s 330ms Dry Circuit Resistance Logarithmic scale Temperature-RTD Temperature-TC Temperature-Thermistor Linear scale Measurement capabilities of the high performance multimeter Accessories Available GPIB Interfaces and Cables 7007-1 Shielded GPIB Cable, 1m (3.5ft) 7007-2 Shielded GPIB Cable, 2m (6.6ft) KPCI-488LPA IEEE-488 Interface/Controller for the PCI Bus KUSB-488B IEEE-488 USB-to-GPIB Interface Adapter Digital I/O, Trigger Link, and TSP-Link 2600-TLINK Trigger I/O to Trigger Link Interface Cable, 1m (3.3 ft) CA-126-1 Digital I/O and Trigger Cable, 1.5m (4.9 ft) CA-180-3A CAT5 Crossover Cable for TSP-Link Multimeter Connectors 3706-BAN DMM Adapter Cable, 15-pin D-sub to banana jacks, 1.4m (4.6 ft) 3706-BKPL Analog Backplane Extender Board, 15-pin D-sub to terminal block 3706-TLK Test Lead Kit, includes 3706-BAN and plug-in test lead accessories 8620 Shorting Plug Services Available Mainframe Models 3706A and 3706A-NFP 3706A-3Y-EW 1 Year Factory Warranty Extended to 3 Years 1 Year Factory Warranty Extended to 5 Years 3706A-5Y-EW C/3706A-3Y-STD Calibration Contract, 3 Years, Standard Calibration* C/3706A-3Y-DATA Calibration Contract, 3 Years, Z540 Compliant Calibration with Data* C/3706A-3Y-ISO Calibration Contract, 3 Years, ISO 17025 Accredited Calibration* C/3706A-5Y-STD Calibration Contract, 5 Years, Standard Calibration* C/3706A-5Y-DATA Calibration Contract, 5 Years, Z540 Compliant Calibration with Data* C/3706A-5Y-ISO Calibration Contract, 5 Years, ISO 17025 Accredited Calibration* Mainframe Models 3706A-S and 3706A-SNFP 3706A-S-3Y-EW 1 Year Factory Warranty Extended to 3 Years 3706A-S-5Y-EW 1 Year Factory Warranty Extended to 5 Years Rack Mount Kit Software Services System Development or Implementation Other service contracts are available; please contact us for details. 4288-10 *Not available in all countries. Fixed Rear Rack Mount Kit Accessories Supplied Test Script Builder Software Suite CD Ethernet Crossover Cable (CA-180-3A) Series 3700A Product CD (includes LabVIEW(R), IVI C, and IVI.COM drivers) 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence System switch with high performance multimeter System switch with high performance multimeter Ordering Information SWITCHING AND CONTROL Series 3700A System Switch/Multimeter and Plug-In Cards TSP Distributed Control Increases Test Speed and Lowers Test Cost TSP technology enhances instrument control by allowing users the choice of using standard PC control or of creating embedded test scripts that are executed on microprocessors within the instrument. By using TSP test scripts instead of a PC for instrument control, you avoid communication delays between the PC controller and instrument, which results in improved test throughput. Test scripts can contain math and decisionmaking rules that further reduce the interaction between a host PC and the instrument. Test Script Builder Software Suite Test Script Builder is a software tool that is provided with all Series 3700A instruments to help users easily create, modify, debug, and store TSP test scripts. It supplies a project/file manager window to store and organize test scripts, a text-sensitive program editor to create and modify test TSP code, and an immediate instrument control window to send Ethernet, GPIB, and USB commands and to receive data from the instrument. The immediate window also allows users to see the output of a given test script and simplifies d ebugging. This form of distributed control supports the autonomous operation of individual instruments or groups of instruments and can possibly remove the need for a high level PC controller, which lowers test and ownership costs. This is the same proven TSP technology found in our innovative Series 2600B System SourceMeter(R) SMU instruments. TSP-Link Technology for Easy and Seamless System Coordination and Expansion If your channel density requirements grow or if you need to process more signal types, use TSP-Link Technology to expand your system. The TSPLink master/slave connection offers easy system expansion between Series 3700A mainframes. You can also use TSP-Link Technology to connect to other TSP-Link enabled instruments such as Series 2600B SourceMeter SMU instruments. Everything connected with TSP-Link can be controlled by the master unit, just as if they were all housed in the same chassis. This high speed system expansion interface lets users avoid the complex and time consuming task of expanding their remote interfaces to another mainframe. There is no need to add external triggers and remote communication cables to individual instruments, since all TSP-Link connected devices can be controlled from a single master unit. Create and modify test TSP code in the context sensitive editor window. Store and organize test scripts in the file manager window. The immediate window displays test script output and assists in debugging. Test Script Builder Software Suite SWITCHING AND CONTROL Version 1.4 LXI Core 2011 with LXI Clock Synchronization, LXI Timestamped Data, LXI Event Messaging, LXI Event Log. Transportable Memory, USB 2.0 Device Port All Model 3706A mainframes contain a USB device port for easy transfer of readings, configurations, and test scripts to memory sticks. This port, which is located on the front panel, provides you with easy access to and portability of measurement results. Simply plug in a memory stick and, with a few simple keystrokes, gain access to virtually unlimited memory storage. Additional capabilities include: saving and recalling system configurations and storage for TSP scripts. 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence System switch with high performance multimeter System switch with high performance multimeter Series 3700A Embedded Web Server The built-in Web interface offers a quick and easy method to control and analyze measurement results. Interactive schematics of each card in the mainframe support point-and-click control for opening and closing switches. A scan list builder is provided to guide users through the requirements of a scan list (such as trigger and looping definitions) for more advanced applications. When the mainframe is ordered with the multimeter, additional Web pages are included for measurement configuration and viewing, including a graphing toolkit. Built-in Web Server Interface 3. Analyze your data. View your results in real-time or historical mode with point-and-click simplicity. Data can be exported directly to your PC in either numerical or graphical formats for presentation or other applications. 1. Configure your switch channels and measurement functions. Configure the DMM to make your measurements at the desired speed, resolution, etc. and assign them to the desired channels. System switch with high performance multimeter System Switch/Multimeter and Plug-In Cards Model 3706A front panel Model 3706A-S front panel 2. Build and run your automated scan list. The toolkit makes it easy to build and execute an automated sequence of channel-open and channel-close commands and triggered multimeter measurements. Model 3706A-NFP and Model 3706A-SNFP front panel Model 3706A rear panel 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence SWITCHING AND CONTROL System switch with high performance multimeter Series 3700A Series 3700A System Switch/Multimeter and Plug-In Cards High Performance Multimeter Specifications (Rev. A) DC Specifications Series 3700A specifications Function Voltage4 Resistance 4, 5, 6, 7 Dry Circuit Resistance 6, 8 Continuity (2W) Current 9 Resolution Range 100.00000 mV 19 0.01 V 0.1 V 1.0000000 V 19 10.000000 V 1 V 100.00000 V 10 V 300.00000 V 100 V 1.0000000 W 0.1 W 10.000000 W 1 W 10 W 100.00000 W 1.0000000 kW 100 W 10.000000 kW 1 mW 10 mW 100.00000 kW 100 mW 1.0000000 MW 10.000000 MW 1 W W 100.00000 MW 10 1.0000000 W 1 W 10.000000 W 10 W 100.00000 W 100 W 1.0000000 kW 1 mW 2.0000000 kW 10 mW 1.000 kW 100 mW 10.000000 A 1 pA 100.00000 A 10 pA 1.0000000 mA 100 pA 10.000000 mA 1 nA 100.00000 mA 10 nA 1.0000000 A 100 nA 3.0000000 A 1 A 1 Test Current or Burden Voltage 10 mA 10 mA 1 mA 1 mA 100 A 10 A 10 A 0.64 A//10 MW 0.64 A//10 MW 10 mA 1 mA 100 A 10 A 5 A 1 mA <61 mV <105 mV <130 mV <150 mV <0.4 V <0.6 V <1.8 V Input Resistance or Open Circuit Voltage2 >10 GW or 10 MW 1% >10 GW or 10 MW 1% >10 GW or 10 MW 1% 10 MW 1% 10 MW 1% 8.2 V 8.2 V 13.9 V 13.9 V 9.1 V 14.7 V 14.7 V 6.4 V 6.4 V 27 mV 20 mV 20 mV 20 mV 20 mV 13.9 V Accuracy: (ppm of reading + ppm of range) (ppm = parts per million) (e.g., 10ppm = 0.001%) 24 Hour3 23C 1C 10 + 9 7+2 7+2 15 + 6 20 + 6 15 + 80 15 + 9 15 + 9 20 + 4 15 + 4 20 + 4 25 + 4 150 + 6 800 + 30 25 + 80 25 + 80 25 + 80 25 + 80 25 + 80 40 + 100 40 + 50 50 + 9 50 + 9 50 + 9 50 + 9 200 + 60 1000 + 75 90 Day 23C 5C 25 + 9 25 + 2 20 + 2 35 + 6 35 + 6 40 + 80 40 + 9 45 + 9 45 + 4 40 + 4 45 + 5 50 + 5 200 + 10 2000 + 30 50 + 80 50 + 80 90 + 80 180 + 80 320 + 80 100 + 100 300 + 50 300 + 30 300 + 30 300 + 30 300 + 30 500 + 60 1200 + 75 1 Year 23C 5C 30 + 9 30 + 2 25 + 2 40 + 6 40 + 6 60 + 80 60 + 9 65 + 9 65 + 4 60 + 4 65 + 5 70 + 5 400 + 10 2000 + 30 70 + 80 70 + 80 140 + 80 400 + 80 800 + 80 100 + 100 500 + 50 500 + 30 500 + 30 500 + 30 500 + 30 800 + 60 1200 + 75 Temperature Coefficient 0-18C and 28-50C (1 + 5)/C (1 + 1)/C (1 + 1)/C (5 + 1)/C (5 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (70 + 1)/C (385 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (35 + 9)/C (50 + 5)/C (50 + 5)/C (50 + 5)/C (50 + 5)/C (50 + 10)/C (50 + 10)/C Temperature SWITCHING AND CONTROL (Displayed in C, F, or K. Exclusive of probes errors.) Thermocouples (Accuracy based on ITS-90): Type J K N T E R S B Range -150 to + 760C -150 to +1372C -100 to +1300C -100 to +400C -150 to +1000C +400 to +1768C +400 to +1768C +1100 to +1820C Resolution 0.001C 0.001C 0.001C 0.001C 0.001C 0.1C 0.1C 0.1C 90 Day/1 Year, 23C 5C Simulated reference junction 0.2C 0.2C 0.2C 0.2C 0.2C 0.6C 0.6C 0.6C 90 Day/1 Year, 23C 5C Using 3720, 3721, or 3724 Cards 1.0C 1.0C 1.0C 1.0C 1.0C 1.8C 1.8C 1.8C Range -200 to -150C -200 to -150C -200 to -100C -200 to -100C -200 to -150C 0 to +400C 0 to +400C +350 to +1100C 90 Day/1 Year, 23C 5C Using 3720, 3721, or 3724 Cards 1.5C 1.5C 1.5C 1.5C 1.5C 2.3C 2.3C 2.8C Temperature Coefficient 0-18C and 28-50C 0.03C/C 0.03C/C 0.03C/C 0.03C/C 0.03C/C 0.03C/C 0.03C/C 0.03C/C 4-Wire RTD or 3-Wire RTD (100W platinum [PT100], D100, F100, PT385, PT3916, or user 0W to 10kW) (Selectable Offset compensation On or Off): For 3-wire RTD, dmm.connect=dmm.CONNECT_FOUR_WIRE, 0.1W lead resistance mismatching in Input HI and LO. Add 0.25C/0.1W of lead resistance mismatch. 4-Wire RTD 3-Wire RTD -200 to +630C -200 to +630C 0.01C 0.01C 0.06C 0.75C 0.003C/C 0.003C/C Thermistor: 2.2kW, 5kW, and 10kW. Not recommended with Model 3724 card. See Model 3724 manual for "Measurement Considerations." -80 to +150C 0.01C 0.08C 0.002C/C 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence Series 3700A specifications Conditions: 1 PLC or 5 PLC. For <1PLC, add appropriate "ppm of range" adder from "RMS Noise" table. Includes rear panel Analog Backplane connector and transducer conversion. Refer to DC Notes for additional card uncertainties. Series 3700A System Switch/Multimeter and Plug-In Cards Single Channel, 60Hz (50Hz) Operation. 1PLC and 5PLC RMS noise are included in DC specifications. Function Series 3700A specifications DCV 2Ww (10kw) DCI 4Ww 4Ww OCOMP Dry-Cktw OCOMP NPLC Aperture (ms) Digits 5 14 83.3 (100) 71/2 16.7 (20) 71/2 1 14 3.33 (4.0) 61/2 0.2 12, 14 0.2 14 3.33 (4.0) 61/2 0.06 15 1.0 (1.2) 51/2 0.100 (0.120) 41/2 0.006 15 15 0.0083 (0.001) 31/2 0.0005 100mV 1.0 0.9 2.5 3.5 12 55 325 1V 0.07 0.12 0.32 1.7 3.0 15 95 1kw 0.5 0.8 1.7 4.5 6 15 190 10V 0.05 0.1 0.3 0.7 1.5 7.0 95 Measurements into Buffer (rdgs/s)13 100V 0.7 0.8 2.5 3.5 8.0 70 900 300V 0.2 0.35 1.0 1.5 3.5 35 410 -- -- -- -- -- -- -- Azero On Azero Off 9.5 (8) 12 (10) 42 (33) 59.8 (49.5) 50 (40) 60 (50) 120 (100) 295 (235) 205 (165) 935 (750) 218 (215) 6,200 (5,500) 270 (270) 14,600 (14,250) Ethernet 86.3 (104) 19.4 (22.7) 19.4 (22.7) 7.6 (8.3) 1.40 (1.80) 0.55 (0.57) 0.50 (0.5) GPIB 86.1 (102.8) 19.5 (22.8) 19.5 (22.8) 6.2 (6.8) 1.50 (1.80) 0.65 (0.67) 0.60 (0.60) USB 86.3 (103.1) 19.9 (23.2) 19.9 (23.2) 6.4 (7.0) 1.60 (2.30) 0.75 (0.77) 0.70 (0.70) -- -- -- -- -- -- -- 9.5 (8) 12 (10) 42 (33) 59.8 (49.5) 50 (40) 60 (50) 120 (100) 295 (235) 205 (165) 935 (750) 218 (215) 6,200 (5,500) 270 (270) 14,100 (13,700) 87.0 (105) 21.0 (24.3) 21.0 (24.3) 7.6 (8.3) 1.40 (1.80) 0.55 (0.57) 0.50 (0.5) 86.1 (103) 19.5 (22.8) 19.5 (22.8) 6.2 (6.8) 1.50 (1.80) 0.65 (0.67) 0.60 (0.60) 86.5 (104) 19.9 (23.2) 19.9 (23.2) 6.4 (7.0) 1.60 (2.30) 0.75 (0.77) 0.70 (0.70) 3A 2.0 1.8 8.0 8.0 20 100 750 9.5 (8) 12 (10) 42 (33) 59.8 (49.5) 50 (40) 60 (50) 120 (100) 295 (235) 205 (165) 935 (750) 218 (215) 6,200 (5,500) 270 (270) 14,100 (13,700) 88 (103) 21.0 (22.7) 19.4 (22.7) 7.6 (8.3) 1.40 (1.80) 0.55 (0.57) 0.50 (0.5) 86.1 (102.8) 19.5 (22.8) 19.5 (22.8) 6.2 (6.8) 1.50 (1.80) 0.65 (0.67) 0.60 (0.60) 86.3 (103.1) 19.8 (23.1) 19.8 (23.1) 6.4 (7.0) 1.60 (2.30) 0.75 (0.77) 0.70 (0.70) 5 14 1 14 0.2 12, 14 0.2 14 0.06 15 0.006 15 0.0005 15 83.3 (100) 16.7 (20) 3.33 (4.0) 3.33 (4.0) 1.0 (1.2) 0.100 (0.120) 0.0083 (0.001) 71/2 71/2 61/2 61/2 51/2 41/2 31/2 10-100w 2.0 3.5 6.5 8.0 15 60 190 5 14 1 14 0.2 12, 14 0.2 14 0.06 15 0.006 15 0.0005 15 83.3 (100) 16.7 (20) 3.33 (4.0) 3.33 (4.0) 1.0 (1.2) 0.100 (0.120) 0.0083 (0.001) 71/2 61/2 51/2 41/2 41/2 41/2 31/2 10A 3.5 3.5 50 100 350 400 2500 100A 1mA-100mA 1A 1.6 1.6 2.9 1.1 1.1 2.2 5.0 3.0 4.0 35 12 4.0 35 20 8.0 200 40 50 450 250 325 5 14 1 14 0.2 12, 14 0.2 14 0.06 15 0.006 15 0.0005 15 83.3 (100) 16.7 (20) 3.33 (4.0) 3.33 (4.0) 1.0 (1.2) 0.100 (0.120) 0.0083 (0.001) 71/2 71/2 51/2 51/2 41/2 41/2 31/2 1w 5.5 15 100 300 500 750 3500 10-100w 0.8 1.4 30 50 50 75 450 1kw 0.5 0.5 10 10 15 30 250 10kw 0.5 0.7 50 63 70 100 250 -- -- -- -- -- -- -- 5 (4) 23.5 (18.5) 26.5 (21) 80 (60) 140 (110) 200 (195) 210 (205) 5.9 (4.7) 29 (23) 30 (24) 120 (95) 285 (225) 580 (565) 650 (645) 173 (206) 39 (46) 39 (46) 12.3 (14.5) 6.2 (7.2) 4.2 (4.4) 4.2 (4.4) 173 (206) 39 (46) 39 (46) 11.3 (13.3) 6.3 (7.3) 4.3 (4.5) 4.3 (4.5) 173 (206) 39 (46) 39 (46) 11.7 (13.7) 6.5 (7.6) 4.6 (4.8) 4.6 (4.8) 5 14 1 14 0.2 12, 14 0.2 14 0.0005 15 83.3 (100) 16.7 (20) 3.33 (4.0) 3.33 (4.0) 0.0083 (0.001) 71/2 71/2 61/2 51/2 31/2 1w 5.5 16 45 500 4500 10-100w 0.8 1.5 4.5 50 650 1kw 0.5 0.7 2.1 13 400 10kw 0.5 1.5 3.5 30 400 -- -- -- -- -- 2.5 (2.0) 12.7 (10) 14 (11.2) 46.5 (37) 129 (125) 2.9 (2.3) 14 (11.2) 15 (12) 56 (44) 215 (210) 343 (427) 77 (95) 70 (86.5) 22.7 (25) 6.7 (6.7) 341 (425) 74 (92) 70 (86.5) 20.5 (23) 6.8 (6.8) 342 (426) 75 (93) 70 (86.5) 21.1 (24) 7 (7) 5 14 1 14 0.2 12, 14 0.2 14 0.0005 15 83.3 (100) 16.7 (20) 3.33 (4.0) 3.33 (4.0) 0.0083 (0.001) 61/2 51/2 41/2 31/2 21/2 1-10w 8.0 17 50 500 8500 100w 10 22 50 1000 8500 1kw 10 25 50 1000 8500 2kw 8.0 28 50 1500 8500 -- -- -- -- -- 2.5 (2.0) 12 (9.5) 14 (11.2) 35 (30) 84 (84) 2.9 (2.3) 13 (10) 15 (12) 45 (36) 115 (110) 347 (430) 80 (99) 70 (86.5) 27 (33) 10.7 (10.7) 345 (428) 77 (95) 70 (86.5) 25 (31) 10.7 (10.7) 346 (429) 78 (97) 70 (86.5) 26 (32) 11 (11) RTD Speeds vs. Noise 10kw 0.4 0.6 1.5 5.5 6.5 15 190 Measurement to PC (ms/rdg) Azero Off 13 1 PLC and 5 PLC Noise are included in RTD Specifications. Single Channel, 60Hz (50Hz) Operation Function NPLC Aperture (ms) Digits 83.3 (100) 71/2 5 14 16.7 (20) 71/2 114 12, 14 3.33 (4.0) 51/2 0.2 3.33 (4.0) 51/2 0.214 OCOMP OFF 1.0 (1.2) 41/2 0.0615 0.100 (0.120) 41/2 0.00615 0.0083 (0.001) 31/2 0.000515 5 14 83.3 (100) 71/2 16.7 (20) 71/2 114 3.33 (4.0) 61/2 0.212, 14 OCOMP ON 3.33 (4.0) 51/2 0.214 0.0083 (0.001) 31/2 0.000515 Add C to Reading 16 4-Wire 3-Wire 0 0 0 0 0.01 0.01 0.18 0.18 0.24 0.24 0.37 0.37 3.10 3.10 0 0 0 0 0.02 0.02 0.38 0.38 4.67 4.67 Measurements into Buffer 13 (rdg/s) Azero On Azero Off 5 (4) 5.9 (4.7) 23.5 (18.5) 29 (23) 26.5 (21) 30 (24) 80 (60) 120 (95) 140 (110) 285 (225) 200 (195) 580 (565) 209 (205) 650 (645) 2.5 (2.0) 2.9 (2.3) 12.7 (10) 14 (11.2) 14 (11.2) 15 (12) 46.0 (37) 56 (44) 128 (125) 215 (210) Measurement to PC 13 (ms/rdg) Azero Off Ethernet GPIB USB 173 (206) 173 (206) 173 (206) 39 (46) 39 (46) 39 (46) 39 (46) 39 (46) 39 (46) 12.3 (14.5) 11.3 (13.3) 11.7 (13.7) 6.2 (7.2) 6.3 (7.3) 6.5 (7.6) 4.2 (4.4) 4.3 (4.5) 4.6 (4.8) 4.2 (4.4) 4.3 (4.5) 4.6 (4.8) 343 (427) 341 (425) 342 (426) 77 (95) 74 (92) 75 (93) 70 (86.5) 70 (86.5) 70 (86.5) 22.7 (25) 20.5 (23) 21.1 (24) 6.7 (6.7) 6.8 (6.8) 7 (7) 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence Series 3700A specifications RMS Noise16, PPM of Range RMS Noise Calculator: Add 2.5 x "RMS Noise" to "ppm of range" (e.g., 10V @ 0.006 PLC) "ppm of range" = 2.5 x 7.0 ppm + 2 ppm SWITCHING AND CONTROL DC Speeds vs. RMS Noise Series 3700A System Switch/Multimeter and Plug-In Cards DC Measurement Characteristics (continued) 31/2-Digit Mode, Azero off, nPLC = 0.0005. Time includes function change from either DCV or 2Ww to listed function. Series 3700A specifications Function DCV or 2Ww (<10kw) 4Ww (<10kw) DCI Frequency or Period 17 ACV or ACI 17 Function Change (ms) 10 20 10 110 20 Buffer Transfer Speed Average for 1000 readings Average for 1000 readings with timestamp Range Change (ms) 10 20 10 10 85 Ethernet 2450/s 2300/s Auto-range (ms) 10 20 10 -- 300 GPIB 2000/s 1800/s USB 1800/s 1600/s Single Command Excecution Time (ms) Card 3720, 3721, 3722, 3730 3723, 3724 3731, 3732 18 3740 Command channel.close (ch_list) or channel.open (ch_list) channel.close (ch_list) or channel.open (ch_list) channel.close (ch_list 1-28) or channel.open (ch_list 1-28) channel.close (ch_list 29-32) or channel.open (ch_list 29-32) Ethernet GPIB USB 5.7 5.8 6.1 2.3 2.4 2.7 10.7 10.8 11.1 22.7 22.8 23.1 Range 3A 1A 100 mA 10 mA 1 mA 100 A 10 A Shunt Resistance 1W 10 W 100 W 1 kW 6 kW guaranteed by design 0.05 W 0.05 W Burden Voltage <1.75 V <0.55 V <0.4 V <150 mV <130 mV <105 mV <61 mV Burden Voltage with <2.35 V <1.15 V <0.4 V <150 mV <130 mV <105 mV <61 mV 3721 card Autozero OFF 100 A 100 A 5 A 0.5 A 50 nA 5 nA 0.85 nA "of range" Error For each additional amp after 1.5A input, add the following to ppm of range: -- 120 60 60 60 60 95 INPUT PROTECTION: 3A, 250V fuse. Thermocouples CONversion: ITS-90. REFERENCE JUNCTION: Internal, External, or Simulated (Fixed). OPEN LEAD DETECTOR: Selectable per channel. Open >1.15kW 50W. Default on. COMMON MODE ISOLATION: 300V DC or 300Vrms (425V peak for AC waveforms), >10GW and <350pF any terminal to chassis. DC Notes DC Measurement Characteristics DC Volts A-D LINEARITY: 1.0ppm of reading + 2.0 ppm of range. INPUT IMPEDANCE: 100mV-10V Ranges: Selectable >10GW // <400pF or 10MW 1%. 100V-300V Ranges: 10MW 1%. Input Bias Current: <50pA at 23C with dmm.autozero=dmm.OFF or dmm.inputdivider=dmm.ON. Common Mode Current: <500nA p-p for 1MHz. Autozero OFF Error: For DCV 1C and 10 minutes, add (8ppm of reading + 5V). Input Protection: 300V all ranges. Common Mode Voltage: 300V DC or 300Vrms (425V peak for AC waveforms) between any terminal and chassis. SWITCHING AND CONTROL DC Current Autozero OFF Error: For 1C and 10 minutes, add (8ppm of reading + range error). Refer to table below. Resistance MAX. 4WW LEAD RESISTANCE: 5W per lead for 1W range; 10% of range per lead for 10W-1kW ranges; 1kW per lead for all other ranges. MAX. 4WW LEAD RESISTANCE (Dry Ckt): 0.5W per lead for 1W range; 10% of range per lead for 10W-100W ranges; 50W per lead for 1kW-2kW ranges. INPUT IMPEDANCE: 1W-10W Ranges: 99kW 1% // <1F. 100W-2kW Ranges: 10MW 1% // <0.015F. OFFSET COMPENSATION: Selectable on 4WW 1W-10kW ranges. OPEN LEAD DETECTOR: Selectable per channel. 1.5A, 20% sink current per DMM SHI and SLO lead. Default on. CONTINUITY THREShOLD: Adjustable 1 to 1000W. Autozero OFF Error: For 2WW 1C and 10 minutes, add (8ppm of reading + 0.5mW) for 10W and 5mW for all other ranges. INPUT PROTECTION: 300V all ranges. 1. 20% overrange on DC functions except 1% on 300V range and 3.33% on 3A range. 2. 5% (measured with 10MW input resistance DMM, >10GW DMM on 10MW and 100MW ranges). Refer to table for other 2W/4W configurations. For Dry Circuit, +20%, <1mV with dmm.offsetcompensation=ON for 100W-2kW ranges. Range 1, 10W 100, 1kW 10kW 100k, 1MW 10M, 100MW 2W 8.2 V 13.9 V 9.1 V 12.7 V 6.4 V 4W 8.2 V 14.1 V 9.1 V 14.7 V 6.4 V 4W-Kelvin 8.2 V 13.9 V 9.1 V 12.7 V 6.4 V 3. Relative to calibration accuracy. 4. Add the following additional uncertainty with -ST accessory: (ppm of range) Card 3720, 3721, 3722, and 3730 3723 3724 3731 3732 (Quad 4x28) 100 mV 45 60 45 800 200 1V 4.5 6.0 4.5 80 20 10 V - - - 8 2 Ocomp 4W 12.1 V 15.0 V 0.0 V -- -- Ocomp 4W-Kelvin 12.1 V 12.7 V 0.0 V -- -- (ppm of reading + ppm of range) 100 kW 8+5 8+6 8+5 8 + 80 8 + 20 1 MW 8 + 0.5 8 + 0.5 80 + 0.5 40 + 8 40 + 2 10 MW -- -- 250 + 1 0 + 25 0+7 100 MW -- -- 5000 + 1 0 + 15 0+4 5. Specifications are for 4-wire W, 1W-1kW with offset compensation on. For Series 3700A plug-in cards, L SYNC and offset compensation on. 1W range is 4-wire only. Model 3724 card: 1kW-100MW ranges only. Model 3731 card: 100W-100MW ranges only. For 2-wire W specifications, add the following to "ppm of range" uncertainty: Rear Panel Connector DMM Connect Relays Rel Enable or 3700 Card 3724 Card 3731 Card CONNECT_ALL ON 100 mW 500 mW 900 mW CONNECT_ALL OFF 1.5 W 64 W 2.3 W CONNECT_TWO_WIRE ON 700 mW 1.2 W 1.5 W CONNECT_TWO_WIRE OFF 1.5 W 64 W 2.3 W 6. Test current with dmm.offsetcompensation=OFF, 5%. 7. Add the following to "ppm of reading" uncertainty when using Series 3700A Plug-in Cards in Operating Environment 50%RH. Card 10 kW 100 kW 1 MW 10 MW 100 MW 3720, 3721, 3724, 3730, 3731, 3732 (Quad 4x28) 1 ppm 10 ppm 0.01% 0.1% 1% with MTC D-Shell connector 3720, 3721, 3724, 3730, 3731, 3732 (Quad 4x28) 10 ppm 100 ppm 0.1% 1% 10% with -ST screw terminal module 10 ppm 100 ppm 0.1% 1% 10% 3722 and 3723 Series 3700A Plug-in Cards Operating Environment: Specified for 0 to 50C, 70%RH at 35C. 8.Dry-Ckt W is 4-wire only. Specifications with offset compensation and L SYNC on. Card Ranges 3720, 3721, and 3730 1 W - 2 kW 3722, 3723, and 3732 10 W - 2 kW 3724 1 kW - 2 kW 3731 100 W - 2 kW 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence Series 3700A specifications System Performance 13, 14 Series 3700A System Switch/Multimeter and Plug-In Cards DC Notes (continued) For Dry-Ckt W with Offset Comp OFF 2kW, 60 rdg/s max. Dry-Ckt W with Offset Comp ON 2kW, 29.5 rdg/s max. For temperature reading rates use DCV for T/C and 2WW for Thermistor. Speeds are typical and include measurements and data transfer out the Ethernet, GPIB, or USB. 9. Includes Analog Backplane 15-pin rear panel connector. For 3721, refer to DC Current table for additional uncertainties. 10.For L SYNC On, line frequency 0.1%. nPLC NMRR NMRR 5 110 dB 60 dB, 2 dB 1 90 dB 60 dB, 2 dB <0.2 45 dB -- 14.DMM configured for single reading, dmm.measurecount=1, and print(dmm.measure()). May require additional settling delays for full accuracy, depending on measurement configuration. <0.01 -- -- 15.DMM configured for multisample readings and single buffer transfer, dmm.measurecount=1000, buf=dmm.makebuffer(1000), dmm.measure(buf), and printbuffer(1,1000,buf). 11.For 1kW unbalance in LO lead. AC CMRR is 70dB. 5 140 dB 1 140 dB 0.2 12 120 dB 16.dmm.autozero=dmm.ON. RMS noise using low thermal short for DCV, 2WW, 4WW, and Dry-Ckt W. For DCI, dmm.connect=dmm.CONNECT_NONE or 0. For RTD, noise using low thermal 190W precision resistor. Includes Model 3721 card accuracies. RMS noise values are typical. 0.2 80 dB 17.For DCV or 2WW to Frequency or Period, dmm.nplc=0.2 and dmm.aperture=0.01 sec. For ACI or ACV, dmm.detectorbandwidth=300. For ACI or ACV with dmm.autodelay=dmm.ON, best speed is 65ms. 12.For LSYNC On. 13.Reading rates are for 60Hz (50Hz) operation using factory defaults operating conditions dmm.reset("all"), Autorange off, dmm.autodelay=dmm.OFF, dmm.opendetector=dmm.OFF, format.data.=format.SREAL. Ranges as follows: DCV = 10V, 2WW/4WW = 1kW, DCI = 1mA, Dry-Ckt W = 10W, ACI = 1mA, and ACV = 1V. 18.Speeds are within same multiplexer bank. Add an additional 8ms when changing banks or slots. 19.When properly zeroed using REL function. AC Specifications Function Voltage2 Current2 Range1 100.0000 mV 1.000000 V 10.00000 V 100.0000 V 300.0000 V 300.0000 V 1.000000 mA7 10.00000 mA 100.0000 mA 1.000000 A 3.000000 A Resolution 0.1V 1V 10V 100V 1 mV 1 mV 1 nA 10 nA 100 nA 1 A 10 A Accuracy: (% of reading + % of range) 23C 5C Calibration Cycle 90 Day (100mV-100V) 1 Year (100mV-100V) 90 Day 1 Year Temp. Coeff. /C3 (all ranges) 90 Day/1 Year Temp. Coeff. /C3 (all ranges) 3 Hz-5 Hz 5 Hz-10 Hz 10 Hz -20 kHz 1.0 + 0.03 0.30 + 0.03 0.05 + 0.03 20 kHz-50 kHz 50 kHz-100 kHz 100 kHz-300 kHz 0.11 + 0.05 0.6 + 0.08 4.0 + 0.5 1.0 + 0.03 0.30 + 0.03 0.06 + 0.03 0.12 + 0.05 0.6 + 0.08 4.0 + 0.5 1.0 + 0.05 1.0 + 0.05 0.30 + 0.05 0.30 + 0.05 0.05 + 0.05 0.06 + 0.05 0.11 + 0.08 0.12 + 0.08 0.6 + 0.11 0.6 + 0.11 4.0 + 0.8 4.0 + 0.8 0.010 + 0.003 0.030 + 0.003 0.005 + 0.003 0.006 + 0.005 0.01 + 0.006 0.03 + 0.01 3 Hz-5 Hz 1.0 + 0.04 1.0 + 0.04 1.0 + 0.04 1.0 + 0.04 1.0 + 0.05 5 Hz-10 Hz 0.30 + 0.04 0.30 + 0.04 0.30 + 0.04 0.30 + 0.04 0.30 + 0.05 10Hz -2 kHz 0.08 + 0.03 0.08 + 0.03 0.08 + 0.03 0.20 + 0.04 0.20 + 0.05 2 kHz -5 kHz 0.09 + 0.03 0.09 + 0.03 0.09 + 0.03 0. 88 + 0.04 0. 88 + 0.05 5 kHz -10 kHz 0.09 + 0.03 0.09 + 0.03 0.09 + 0.03 2.0 + 0.04 2.0 + 0.05 0.10 + 0.004 0.030 + 0.004 0.005 + 0.003 0.006 + 0.005 0.006 + 0.005 Accuracy: (ppm of reading + offset ppm) Frequency4 and Period 100.0000 mV to 300.0000 V 0.333 ppm 3.33 ppm 33.3 ppm 90 Day/1 Year (all ranges) 3 Hz-500 kHz 80 + 0.333 80 + 3.33 80 + 33.3 3 Hz-500 kHz 80 + 0.333 80 + 3.33 80 + 33.3 333 ms-2 s (0.25 s gate) (100 ms gate) (10 ms gate) Additional Uncertainty (% of reading) Low Frequency Uncertainty 20 Hz-30 Hz 30 Hz-50 Hz 50 Hz-100 Hz 100 Hz-200 Hz 200 Hz-300 Hz 300 Hz-500 Hz >500 Hz Detector Bandwidth 3 (3 Hz-300 kHz) 0 0 0 0 0 0 0 30 (30 Hz-300 kHz) 0.3 0 0 0 0 0 0 300 (300 Hz-300 kHz) - - 4.0 0.72 0.18 0.07 0 Additional Uncertainty (% of reading) 5 Hz-10 Hz 10 Hz-30 Hz 30 Hz-100 Hz >100 Hz 300 Hz-500 Hz 500 Hz Detector Bandwidth 3 3 3 or 30 3 or 30 300 only 300 only 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence Crest Factor5 Maximum Crest Factor: 5 at full-scale 1-2 2-3 3-4 4-5 0.50 1.20 1.30 1.40 0.20 0.30 0.60 0.90 0.20 0.30 0.60 0.90 0.05 0.15 0.30 0.40 1.20 1.30 1.40 0.50 0.05 0.15 0.30 0.40 SWITCHING AND CONTROL Series 3700A specifications nPLC CMRR Series 3700A specifications LSYNC On LSYNC Off Series 3700A Single Channel, 60Hz (50Hz) Operation Function ACI / ACV Series 3700A specifications Frequency/Period Measurements into Buffer 9 (rdg/s) Detector Bandwidth 3 30 300 300 300 300 300 NPLC N/A N/A 1.0 10 0.2 10 0.06 11 0.006 11 0.0005 11 Aperture (ms) N/A N/A 16.67 (20) 3.33 (4.0) 1.0 (1.2) 0.100 (0.120) 0.0083 (0.001) Digits 61/2 61/2 61/2 61/2 51/2 41/2 31/2 N/A N/A 10-273 N/A Azero On 0.45 (0.45) 2.5 (2.5) 42 (33) 120 (100) 170 (165) 218 (215) 218 (215) 2x input period + gate time AC Measurement Characteristics N/A Measurement to PC 9 (ms/rdg) Ethernet 2150 (2150) 400 (400) 19.4 (22.7) 7.6 (8.3) 1.40 (1.80) 0.55 (0.57) 0.50 (0.5) 2x input period + gate time + 2.7ms AC Current Measurement Method: AC-coupled, True RMS. 1A 100 mA 10 mA 1 mA 0.05 W 1.0 W 10 W 100 W <0.55 V rms <0.4 V rms <150 mV rms <125 mV rms <1.0 V rms <0.6 V rms <200 mV rms <130 mV rms Input Protection: 3A, 250V fuse. Frequency and Period Measurement Method: Reciprocal Counting technique. Gate Time: dmm.aperture=0.2730.01. Default 0.01s. USB 2150 (2150) 400 (400) 19.8 (23.1) 6.4 (7.0) 1.60 (2.30) 0.75 (0.77) 0.70 (0.70) 2x input period + gate time + 3.1ms 1. 20% overrange on AC functions except 1% on 300V and 3.33% on 3A. Default resolution is 51/2 digits, maximum useable resolution is 61/2 with 71/2 digits programmable. 2. Specification are for Detector Bandwidth 3 and sinewave inputs >5% of range. Detector Bandwidth 3 and 30 are multi-sample A/D conversions. Detector bandwidth 300 is a single A/D conversion, programmable from 0.0005PLC to 15PLC. Default condition set to 1PLC. 3. Applies to 0-18C and 28-50C. 4. Specified for square wave inputs. Input signal must be >10% of ACV range. If input is <20mV on the 100mV range then the frequency must be >10Hz. For sinewave inputs, frequency must be >100Hz. 5. Applies to non-sinewave inputs 5Hz->10kHz, and DC content 3% of range. 6. For 1kW unbalance in LO lead. 7. For Model 3721, 1mA ACI, add 0.05% to "of reading" uncertainty from 250Hz 10kHz. 8. Shunt resistance guaranteed by design. 9. Reading rates are for 60Hz (50Hz) operation using factory defaults operating conditions dmm.reset("all"), Autorange off, dmm.autodelay=dmm.OFF, dmm.opendetector=dmm.OFF, format.data.=format.SREAL. Ranges as follows: DCV = 10V, 2WW/4WW = 1kW, DCI = 1mA, Dry-Ckt W = 10W, ACI = 1mA, and ACV = 1V. For DryCkt W with Offset Comp OFF 2kW, 60 rdg/s max. Dry-Ckt W with Offset Comp ON 2kW, 29.5 rdg/s max. For temperature reading rates use DCV for T/C and 2WW for Thermistor. Speeds are typical and include measurements and data transfer out the Ethernet, GPIB, or USB. 10.DMM configured for single reading, dmm.measurecount=1, and print(dmm.measure()). May require additional settling delays for full accuracy, depending on measurement configuration. 11.DMM configured for multisample readings and single buffer transfer, dmm.measurecount=1000, buf=dmm.makebuffer(1000), dmm.measure(buf), and printbuffer(1,1000,buf). AC General AC CMRR6: 70dB. Volt*Hertz Product: 8x107 Volt*Hz (guaranteed by design), 2.1x107 Volt*Hz verified. Input frequency verified for 3x105 Hz. SWITCHING AND CONTROL GPIB 2150 (2150) 400 (400) 19.5 (22.8) 6.2 (6.8) 1.50 (1.80) 0.65 (0.67) 0.60 (0.60) 2x input period + gate time + 2.8ms AC Notes AC Volts Measurement Method: AC-coupled, True RMS. Input Impedance: 1MW 2% // by <150pF. Input Protection: 300VDC or 300Vrms rear inputs or 37xx cards. Range 3A Shunt Resistance 0.05 W guaranteed by design Burden Voltage <1.75 V rms Rear Panel Burden Voltage <2.4 V rms 3721 Card Azero Off N/A N/A 59.5 (50) 295 (235) 935 (750) 6,200 (5,500) 14,600 (14,250) 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence Series 3700A specifications AC Speeds System Switch/Multimeter and Plug-In Cards Series 3700A System Switch/Multimeter and Plug-In Cards ISINK, max. Absolute V IN V IH min V IL max VOL max at 5mA Isink VOL max at Isink max VOH min, 0.4mA source Min V IN pulse Min VO pulse I/O 1-9 5 mA 5.25 V to -0.25 V 2.2 V 0.7 V 0.7 V -- 2.7 V 2 s 1 s I/O 10-14 250 mA 5.25 V to -0.25 V 2.2 V 0.7 V 0.7 V 2.3 V 2.4 V 10 s 50 s I/O 1-9 +5V 5k 100 Read IN/OUT Write GND I/O 10-14 +5V 5k Read 100 Vext IN/OUT Write GND Vext -- 5 V to 33 V -- -- -- -- -- -- -- TRIGGERING AND MEMORY: Window Filter Sensitivity: 0.01%, 0.1%, 1%, 10%, or full-scale of range (none). Trigger Delay: 0 to 99 hrs. (10s step size). External Trigger Delay: <10s. Memory: Up to 650,000 time-stamped readings with Web page disabled. Additional memory available with external "thumb drive." Non-volatile Memory: Single user save setup, with up to 75 DMM configurations and 600 channel patterns (dependent on name length, DMM function and configuration, and pattern image size). Additional memory available with external "thumb drive." MATH FUNCTIONS: Rel, dB, Limit Test, %, 1/x, and mX+b with user defined displayed. REMOTE INTERFACE: Ethernet: RJ-45 connector, LXI Class B Version 2, 10/100BT, no auto MDIX. GPIB: IEEE-488.1 compliant. Supports IEEE-488.2 common commands and status model topology. USB Device (rear panel, type B): Full speed, USBTMC compliant. USB Host (front panel, type A): USB 2.0, support for thumb drives. LXI COMPLIANCE: LXI Class B Version 2 with IEEE 1588 precision time protocol. LXI TIMING (applies to scanning) and SPECIFICATION: Receive LAN[0-7] Event Delay: n/s (not specified) min., 800s typ., n/s max. Alarm to Trigger Delay: 25s min., 50s typ., n/s max. Generate LAN[0-7] Event: n/s min., 800s typ., n/s max. (minimums are probabilistic and represent a 95% confidence factor). Clock Accuracy: 25ppm. Synchronization Accuracy: <150ns (probabilistic and represents a 95% confidence factor). Timestamp Accuracy: 100s. Timestamp Resolution: 20ns. LANGUAGE: Embedded Test Script Processor (TSP) accessible from any host interface. Responds to individual Instrument Control Library (ICL) commands. Responds to high-speed test scripts comprised of ICL commands and Test Script Language (TSL) statements (e.g., branching, looping, math, etc.). Able to execute high-speed test scripts stored in memory without host intervention. IP CONFIGURATION: Static or DHCP. PASSWORD PROTECTION: 11 characters MINIMUM PC HARDWARE: Intel Pentium 3, 800MHz, 512Mbyte RAM, 210Mbyte disk space or better. OPERATING SYSTEMS/SOFTWARE: Windows(R) 2000 and XP compatible, supports Web browsers with Java plug-in (requires Java plug-in 1.6 or higher). Web pages served by 3706A. OPERATING ENVIRONMENT: Specified for 0 to 50C, 80%RH at 35C, altitude up to 2000 meters. STORAGE ENVIRONMENT: -40 to 70C. DIMENSIONS: Rack Mounted: 89mm high x 483mm wide x 457mm deep (3.5 in. x 19 in. x 18 in.). Bench Configuration (includes handle and feet): 104mm high x 483mm wide x 457mm deep (4.125 in. x 19 in. x 18 in.) SHIPPING WEIGHT: 13kg (28 lbs). Series 3700A specifications EXPANSION SLOTS: 6. POWER LINE: Universal, 100V to 240V. LINE FREQUENCY: 50Hz and 60Hz, automatically sensed at power-up. POWER CONSUMPTION: 28VA with DMM and display, up to 140VA with six 37xx cards. REAL TIME CLOCK: Battery backed, 10 years typical life. EMC: Conforms to European Union EMC Directive. SAFETY: Conforms to European Union Low Voltage Directive. VIBRATION: MIL-PRF-28800F Class 3, Random. WARM-UP: 2 hours to rated accuracy. DIGITAL I/O: 25-pin female D-shell. SWITCHING AND CONTROL Series 3700A specifications GENERAL 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence