DC/DC Converters THD 10WIN Series, 10 Watt CB Scheme IEC 60950-1 UL 60950-1 Features UItra wide 4:1 input voltage range Internal EMI-filter meets EN 55022, class A without external components High efficiency up to 87% Operating temperature range -40C to +85C No minimum load required I/O isolation 1'500 VDC Overload protection 3-year product warranty The THD 10WIN series is designed for an optimized cost/performance ratio of DC/DC converters with output power of 10 Watt. They come with an internal EMI-filter to meet EN55022, class A without external components. General features like no minimum load requirement, overload protection and high efficiency make these converters easy to design in. With the popular DIP-24 standard package they are also a drop in replacement for many cost critical applications. Models Order code Input voltage Output voltage range Output current Efficiency typ. max. THD 10-2410WIN 3.3 VDC 2700 mA 86 % THD 10-2411WIN 5.1 VDC 2000 mA 85 % THD 10-2412WIN 9 - 36 VDC 12 VDC 833 mA 87 % THD 10-2413WIN (24 VDC nominal) 15 VDC 666 mA 87 % THD 10-2415WIN 24 VDC 416 mA 87 % THD 10-2422WIN 12 VDC 416 mA 87 % THD 10-2423WIN 15 VDC 333 mA 87 % THD 10-4810WIN 3.3 VDC 2700 mA 86 % THD 10-4811WIN 5.1 VDC 2000 mA 85 % THD 10-4812WIN 18 - 75 VDC 12 VDC 833 mA 87 % THD 10-4813WIN (48 VDC nominal) 15 VDC 666 mA 87 % THD 10-4815WIN 24 VDC 416 mA 87 % THD 10-4822WIN 12 VDC 416 mA 87 % THD 10-4823WIN 15 VDC 333 mA 87 % http://www.tracopower.com Page 1 of 3 DC/DC Converters THD 10WIN Series 10 Watt Input Specifications Input current at no load 24 Vin models: 30 mA typ. 48 Vin models: 20 mA typ. Recommended input fuse (slow blow) 24 Vin models: 2000 mA 48 Vin models: 1000 mA Start-up voltage / under voltage shut down 24 Vin models: 9 VDC / 8.5 VDC (or lower) 48 Vin models: 18 VDC / 17 VDC (or lower) Surge voltage (1 sec. max.) 24 Vin models: 50 V max. 48 Vin models: 100 V max. Conducted noise EN 55022 class A without external components ESD (electrostatic discharge) EN 61000-4-2, air 8 kV, contact 6 kV, perf. criteria A Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A Fast transient / surge EN 61000-4-4, 2 kV, perf. criteria A EN 61000-4-5, 1 kV perf. criteria A with external capacitor chemi-con KY 220 F, 100 V Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A Output Specifications Voltage set accuracy 2 % max. Regulation - Input variation Vin min. to Vin max. 1.0 % max. - Load variation 0 - 100 % single output models: 1.2 % max. dual output models balanced load: 2.0 % max. Minimum load not required Temperature coefficient 0.02 %/K Ripple and noise (20 MHz Bandwidth) 100 mVp-p max. Transient recovery time (25% load step change) 300 S response time typ. Transient response deviation (25% load step change) 5 % max. Current limitation 110-150 % of Iout hiccup, automatic recovery Short circuit protection hiccup, automatic recovery Over load protection 150 % of Iout max. typ. Capacitive load 3.3 & 5.1 VDC 12 VDC 15 VDC 24 VDC 12 VDC 15 VDC models: models: models: models: models: models: 1000 F max. 470 F max. 330 F max. 150 F max. 220 F max. (each output) 150 F max. (each output) General Specifications Temperature ranges - Operating (natural convection 20 LFM) -40C to +85C - Case temperature +105C max. - Storage -50C to +125C Derating 3.3 %/K above +70C Humidity (non condensing) 95 % rel H max. Reliability, calculated MTBF (MIL-HDBK-217F, at +25C, ground benign) 1`000`000 h Isolation voltage (input/output 60 sec., rated) 1'500 VDC Isolation capacitance (input/output, 100 KHz, 1 V) 1`000 pF typ. Isolation resistance (input/output, 500 VDC) >1`000 M Ohm All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. http://www.tracopower.com Page 2 of 3 DC/DC Converters THD 10WIN Series 10 Watt General Specifications Remote On/Off - On: 3.5 ... 12 VDC or open circuit - Off: 0 ... +1.2 VDC or short circuit pin 1 and pin 2 - Off idle current: 10 mA max. Switching frequency 330 kHz typ. Safety standards UL/cUL 60950-1, IEC/EN 60950-1 Safety approvals - CSA certificate of compliance CAN/CSA-C22.2 No 60950-1-07, Am 1:2011 ANSI/UL Std No 60950-1, 2nd Ed, AM 1:2011 - CB test certificate IEC 60950-1:2005 2nd Ed, Am 1:2009 - Certification documents www.tracopower.com/overview/thd10win Environmental compliance - Reach www.tracopower.com/products/reach-declaration.pdf - RoHS RoHS directive 2011/65/EU Physical Specifications Casing metal with non conductive baseplate Pin copper alloy with gold plated nickel subplate Weight 17.3 g (0.61 oz) Soldering temperature (1.5mm from case for 10 sec.) max. 260C Outline Dimensions Pin-Out 15.24 (0.60) 2.54 (0.10) 14 5.08 4.5 (0.20) (0.18) Pin Single Dual 1 Remote On/Off Remote On/Off 2 -Vin (GND) -Vin (GND) 3 -Vin (GND -Vin (GND (1.25) 4.1 (0.16) 10.2 (0.40) 31.8 (0.80) 16 2.54 23 22 15.22 Bottom view 20.3 11 (0.60) 9 (0.10) 1 2 3 9 No pin Common 11 No function -Vout 14 +Vout +Vout 16 -Vout Common 22 +Vin (Vcc) +Vin (Vcc) 23 +Vin (Vcc) +Vin (Vcc) 4.5 (0.18) 2.54 (0.10) 15.24 (0.60) Dimensions in [mm], () = Inch Pin diameter o 0.5 0.05 (0.02 0.002) Tolerances 0.5 (0.02) Pin pitch tolerances 0.25 (0.01) 5.08 (0.20) Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com www.tracopower.com Rev. June 27, 2018 Page 3 of 3