Inductive sensor NCB10-30GM40-N0 Dimensions 5 37 40 M30x1,5 0 10 2 36 LED Model Number NCB10-30GM40-N0 Features * * Comfort series 10 mm embeddable Connection BN BU L+ L- Accessories BF 30 Mounting flange, 30 mm Technical Data General specifications Switching element function Rated operating distance sn Installation Output polarity Assured operating distance sa Reduction factor rAl Reduction factor rCu Reduction factor rV2A Nominal ratings Nominal voltage Uo Switching frequency f Hysteresis H Reverse polarity protected Short-circuit protection Suitable for 2:1 technology Current consumption Measuring plate not detected Measuring plate detected Indication of the switching state Ambient conditions Ambient temperature Storage temperature Mechanical specifications Connection type Core cross-section Housing material Sensing face Protection degree General information Use in the hazardous area Category Compliance with standards and directives Electromagnetic compatibility Standards 8.2 V (Ri approx. 1 k) 0 ... 650 Hz 1 ... 10 typ. 5 % reverse polarity protected yes yes , reverse polarity protection diode not required 3 mA 1 mA LED, yellow -25 ... 100 C (-13 ... 212 F) -40 ... 100 C (-40 ... 212 F) cable PVC , 2 m 0.75 mm2 Stainless steel PBT IP66 / IP67 see instruction manuals 1G; 2G; 3G; 1D EN 60947-5-6:2000 IEC 60947-5-6:1999 NE 21:2007 EN 60947-5-2:2007 IEC 60947-5-2:2007 Approvals and certificates FM approval Control drawing UL approval CSA approval CCC approval 116-0165F cULus Listed, General Purpose cCSAus Listed, General Purpose Products with a maximum operating voltage of 36 V do not bear a CCC marking because they do not require approval. Release date: 2010-11-16 09:25 Date of issue: 2010-11-18 106282_ENG.xml Standard conformity NAMUR NAMUR, NC 10 mm embeddable NAMUR 0 ... 8.1 mm 0.32 0.32 0.72 Subject to modifications without notice Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com Germany: +49 621 776-4411 fa-info@pepperl-fuchs.com Copyright Pepperl+Fuchs Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com 1 Inductive sensor NCB10-30GM40-N0 ATEX 1G Instruction Manual electrical apparatus for hazardous areas Device category 1G for use in hazardous areas with gas, vapour and mist Directive conformity 94/9/EG Standard conformity EN 60079-0:2006, EN 60079-11:2007, EN 60079-26:2007 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions CE symbol 0102 Ex-identification II 1G Ex ia IIC T6 EC-Type Examination Certificate PTB 00 ATEX 2048 X Appropriate type NCB10-30GM...-N0... Effective internal capacitance Ci Effective internal inductance Li 105 nF ; a cable length of 10 m is considered. Cable length Dangerous electrostatic charges on the fixed connection cable must be taken into account for lengths equal to and exceeding the following values: Explosion group IIA 78 cm 100 H ; a cable length of 10 m is considered. Explosion group IIB 39 cm Explosion group IIC 6 cm General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive 94/9/EG and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Highest permissible ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1:2007 has already been accounted for in the temperature table for category 1. Installation, Comissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Due to the possible danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation of the power supply and signal circuit is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. Maintenance No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. Special conditions When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. Electrostatic charging Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. When used in group IIC non-permissible electrostatic charges should be avoided on the plastic housing parts. Release date: 2010-11-16 09:25 Date of issue: 2010-11-18 106282_ENG.xml Protection from mechanical danger 2 Subject to modifications without notice Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com Germany: +49 621 776-4411 fa-info@pepperl-fuchs.com Copyright Pepperl+Fuchs Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com Inductive sensor NCB10-30GM40-N0 ATEX 2G Instruction Manual electrical apparatus for hazardous areas Device category 2G for use in hazardous areas with gas, vapour and mist Directive conformity 94/9/EG Standard conformity EN 60079-0:2006, EN 60079-11:2007 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions CE symbol 0102 Ex-identification II 1G Ex ia IIC T6 EC-Type Examination Certificate PTB 00 ATEX 2048 X NCB10-30GM...-N0... Appropriate type Effective internal capacitance Ci 105 nF ; a cable length of 10 m is considered. Effective internal inductance Li 100 H ; a cable length of 10 m is considered. General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive 94/9/EG and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Highest permissible ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, Comissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. Maintenance No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. Special conditions When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. Electrostatic charging Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Release date: 2010-11-16 09:25 Date of issue: 2010-11-18 106282_ENG.xml Protection from mechanical danger Subject to modifications without notice Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com Germany: +49 621 776-4411 fa-info@pepperl-fuchs.com Copyright Pepperl+Fuchs Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com 3 Inductive sensor NCB10-30GM40-N0 ATEX 1D Instruction Manual electrical apparatus for hazardous areas Device category 1D for use in hazardous areas with combustible dust Directive conformity 94/9/EG Standard conformity IEC 61241-11:2002: draft; prEN61241-0:2002 type of protection intrinsic safety "iD" Use is restricted to the following stated conditions CE symbol 0102 Ex-identification II 1D Ex iaD 20 T 108 C (226.4 F) EC-Type Examination Certificate ZELM 03 ATEX 0128 X Appropriate type NCB10-30GM...-N0... Effective internal capacitance Ci Effective internal inductance Li 105 nF ; a cable length of 10 m is considered. General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Maximum housing surface temperature The maximum surface temperature of the housing is given in the EC-Type Examination Certificate. Installation, Comissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy at least the requirements of category ia IIB or iaD. Because of the possibility of the danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation in the power supply and signal circuits is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. The intrinsically safe circuit has to be protected against influences due to lightning. When used in the isolating wall between Zone 20 and Zone 21 or Zone 21 und Zone 22 the sensor must not be exposed to any mechanical danger and must be sealed in such a way, that the protective function of the isolating wall is not impaired. The applicable directives and standards must be observed. Maintenance No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. 100 H ; a cable length of 10 m is considered. Special conditions Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. The connection cables are to be laid in accordance with EN 50281-1-2 and must not normally be subjected to chaffing during use. Release date: 2010-11-16 09:25 Date of issue: 2010-11-18 106282_ENG.xml Electrostatic charging 4 Subject to modifications without notice Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com Germany: +49 621 776-4411 fa-info@pepperl-fuchs.com Copyright Pepperl+Fuchs Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com Inductive sensor NCB10-30GM40-N0 ATEX 3G (nL) Note This instruction is only valid for products according to EN 60079-15:2003, valid until 31-May-2008 Instruction Manual electrical apparatus for hazardous areas Device category 3G (nL) for use in hazardous areas with gas, vapour and mist Directive conformity 94/9/EG Standard conformity EN 60079-15:2003 Ignition protection category "n" Use is restricted to the following stated conditions CE symbol 0102 Ex-identification II 3G EEx nL IIC T6 X Effective internal capacitance Ci 105 nF ; a cable length of 10 m is considered. Effective internal inductance Li 100 H ; A cable length of 10 m is considered. General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! Directive 94/9EG is generally applicable only to the use of electrical apparatus operating at atmospheric conditions. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Installation, Comissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. The sensor must only be operated with an energy-limited circuit, which satisfies the requirements of IEC 60079-15. The explosion group complies with the connected, supplying, power limiting circuit. Maintenance No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. Special conditions Maximum permissible ambient temperature TUmax at Ui = 20 V for Pi=34 mW, Ii=25 mA, T6 70 C (158 F) for Pi=34 mW, Ii=25 mA, T5 85 C (185 F) for Pi=34 mW, Ii=25 mA, T4-T1 100 C (212 F) for Pi=64 mW, Ii=25 mA, T6 70 C (158 F) for Pi=64 mW, Ii=25 mA, T5 85 C (185 F) for Pi=64 mW, Ii=25 mA, T4-T1 100 C (212 F) for Pi=169 mW, Ii=52 mA, T6 62 C (143.6 F) for Pi=169 mW, Ii=52 mA, T5 77 C (170.6 F) for Pi=169 mW, Ii=52 mA, T4-T1 81 C (177.8 F) for Pi=242 mW, Ii=76 mA, T6 54 C (129.2 F) for Pi=242 mW, Ii=76 mA, T5 63 C (145.4 F) for Pi=242 mW, Ii=76 mA, T4-T1 63 C (145.4 F) The sensor must not be mechanically damaged. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. Electrostatic charging Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Connection parts The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. Release date: 2010-11-16 09:25 Date of issue: 2010-11-18 106282_ENG.xml Protection from mechanical danger Subject to modifications without notice Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com Germany: +49 621 776-4411 fa-info@pepperl-fuchs.com Copyright Pepperl+Fuchs Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com 5 Inductive sensor NCB10-30GM40-N0 ATEX 3G (ic) Instruction Manual electrical apparatus for hazardous areas Device category 3G (ic) for use in hazardous areas with gas, vapour and mist Directive conformity 94/9/EG Standard conformity EN 60079-11:2007 Ignition protection category "ic" Use is restricted to the following stated conditions CE symbol 0102 Ex-identification II 3G Ex ic IIC T6 X Effective internal capacitance Ci 105 nF ; a cable length of 10 m is considered. Effective internal inductance Li 100 H ; A cable length of 10 m is considered. General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! Directive 94/9EG is generally applicable only to the use of electrical apparatus operating at atmospheric conditions. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Installation, Comissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. The sensor must only be operated with energy-limited circuits, which satisfy the requirements of IEC 60079-11. The explosion group complies with the connected, supplying, power limiting circuit. Maintenance No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. Special conditions Maximum permissible ambient temperature TUmax at Ui = 20 V for Pi=34 mW, Ii=25 mA, T6 70 C (158 F) for Pi=34 mW, Ii=25 mA, T5 85 C (185 F) for Pi=34 mW, Ii=25 mA, T4-T1 100 C (212 F) for Pi=64 mW, Ii=25 mA, T6 70 C (158 F) for Pi=64 mW, Ii=25 mA, T5 85 C (185 F) for Pi=64 mW, Ii=25 mA, T4-T1 100 C (212 F) for Pi=169 mW, Ii=52 mA, T6 62 C (143.6 F) for Pi=169 mW, Ii=52 mA, T5 77 C (170.6 F) for Pi=169 mW, Ii=52 mA, T4-T1 81 C (177.8 F) for Pi=242 mW, Ii=76 mA, T6 54 C (129.2 F) for Pi=242 mW, Ii=76 mA, T5 63 C (145.4 F) for Pi=242 mW, Ii=76 mA, T4-T1 63 C (145.4 F) The sensor must not be mechanically damaged. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. Electrostatic charging Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Connection parts The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. Release date: 2010-11-16 09:25 Date of issue: 2010-11-18 106282_ENG.xml Protection from mechanical danger 6 Subject to modifications without notice Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com Germany: +49 621 776-4411 fa-info@pepperl-fuchs.com Copyright Pepperl+Fuchs Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com