Selection
Guide
Static
Removers
Pulse Air-gun
Cleaning Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
Wide-area Ionizer Steady-state DC Method
ER-TF SERIES
Slim in shape, Wide in charge removal area,
An evolutionary form in expression
General terms and conditions ............. F-3 Selection guide ........................... P.1155~
Glossary of terms.......................... P.1591 General precautions ..................... P.1595
panasonic.net/id/pidsx/global
No compressed air necessary
(Illustration)
Safe design
A monitoring function stops discharge operation if any
foreign material or object is detected in the discharge
unit. This capability provides peace of mind when
working with the unit since you can rest assured that the
high-voltage circuit will stop if your nger approaches the
unit.
Overhead
setup
Desktop
setup
Flexible layout
Thanks to its space-saving design, the ER-TF series
delivers a sufciently large charge removal area while
allowing you to make effective use of your workspace. It
can be mounted on a shelf or pipe or placed directly on
the working surface. The unit adapts exibly to the local
working environment.
Easy maintenance
Discharge units can be removed with a single touch,
making it easy to clean them or replace them as they
naturally wear down. Units can also be cleaned with a
commercially available ultrasonic cleaner.
Available quiet fan cover (optional)
An available fan cover reduces fan suction noise without
reducing air volume.
Wide-area Ionizer ER-TF SERIES
1176
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse Air-gun
Cleaning Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
APPLICATIONS
Indicators showing operation conditions
Front
setup
Overhead
setup
Desktop
setup
This section will now explain the indicator lights that
indicate such abnormalities as maintenance time of the
discharge needle unit and the decrease in the amount of
ventilation due to lter clogging.
POWER
(Green LED)
ERROR
(Red LED)
CHECK
(Orange LED)
FAN
(Yellow LED)
BAR
(Yellow LED)
ERROR indicator:
Lights up when an intrusion of a foreign object into the
discharger is detected by the entry detection function,
or when an abnormal discharge, air intake constraint
caused by clogged lter, or any other abnormality of the
fan is detected.
CHECK indicator:
Lights up when it is time for maintenance of the
discharge needle unit, or when a drop in the fan speed
resulting from lter clogging is detected.
FAN indicator:
Lights up when a fan error or a fan check is detected.
BAR indicator:
Lights up when a discharger error or a discharger check
is detected.
Airow adjustable in 4 levels
Fan speed can be
adjusted in 4 levels.
By setting the fan speed
to MAX, speedy static
removal of wide area is
possible.
Silent fan cover (option) is available.
Without decreasing the airow,
it is possible to reduce noise
during fan suction.
You can easily attach the silent
fan cover to the front of the main
unit fan with a single step.
Easy lter cleaning
The fan air intake lter
can be easily taken
out by sliding open
the cover. This greatly
reduces the man-hour in
cleaning.
Silent fan cover
(optional)
ER-TFSC
1177
Wide-area Ionizer ER-TF SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
ORDER GUIDE
Ionizer main unit
Type
Appearance Charge removal time
(±1,000 V → ±100 V) Ion balance Model No.
Wide-area fan type 1 sec. approx. (Note 1) ±10 V or less (Note 2)
ER-TF04-EX
ER-TF06-EX
ER-TF08-EX
Notes: 1) Typical value at 200 mm 7.874 in from directly in front of air outlet at the unit center at maximum fan speed.
2) Typical value at 300 mm 11.811 in from directly in front of air outlet at the unit center at maximum fan speed.
3) Please prepare an AC cable separately as it is needed.
The following cables are available as optionals:
CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KTL)
Mounting unit
ER-TF06MS1
Air lter
ER-TFF×10
Discharge needle unit
ER-TFANT
Designation Model No. Description
AC cable CN-ACCN-C2
AC cable (conforming to CCC), Length: 2 m 6.562 ft
CN-ACKR-C2
AC cable (conforming to KTL), Length: 2 m 6.562 ft
Mounting unit ER-TF06MS1 Mounting unit for ER-TF06-EX. Allows easy
attachment or detachment of the main unit.
Air lter ER-TFF×10 Air lter for fan air intake part (10 pcs. per set)
Discharge needle unit
ER-TFANT Unit with tungsten needles (1 pc.)
Silent fan cover ER-TFSC To be mounted on the front part of the fan unit
as a cover to reduce the fan blowing sound.
Silent fan cover
ER-TFSC
OPTIONS
Connector conguration
(IEC 60320 C7)
Wide-area Ionizer ER-TF SERIES
1178
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
SPECIFICATIONS
Type Wide-area fan type
Item Model No. ER-TF04-EX ER-TF06-EX ER-TF08-EX
CE marking directive compliance
EMC Directive, RoHS Directive
Charge removal time (±1,000 V → ±100 V)
1 sec. approx. (Note 2)
Ion balance ±10 V or less (Note 3)
Ozone generation 0.02 ppm or less (Note 3)
Power supply voltage Accessory AC adapter input: 100-240 V AC ±10 % 50/60 Hz (Note 4)
(Output: 24 V DC)
Power consumption 80 VA or less (at 100 V: 70 VA or less)
Discharge method Steady-state DC
Discharge output voltage ±6,000 V approx.
Error output
NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1 V or less (at 50 mA sink current)
Output operation OFF if abnormal discharge, object inserted into discharge window or fan problem detected; normally ON
Short-circuit protection Incorporated
Indicators
Bar
POWER Green LED (Lights up when the power is ON)
ERROR Red LED (Lights up when discharge part error or fan error is detected)
CHECK Orange LED (Lights up when discharge part check or fan check is detected)
Fan
Discharge part
status Yellow LED (Lights up when discharge part error or discharge part check is detected)
Fan status Yellow LED (Lights up when fan error or fan check is detected)
Ambient temperature 0 to +50 °C +32 to +122 °F (No dew condensation), AC adapter: 0 to +40 °C +32 to +104 °F
Ambient humidity 35 to 65 % RH (No dew condensation allowed)
Material
Bar unit enclosure: ABS, Fan unit enclosure: ABS, Discharge needles: Tungsten, Mounting bracket: Cold rolled carbon steel (SPCC)
Weight Net weight: 1.0 kg approx. Net weight: 1.2 kg approx. Net weight: 1.4 kg approx.
Accessories
AC adapter (Note 3), F.G. connection cable: 1 pc., Spare replacement lters: 5 pcs., Three-pronged outlet with ground pin: 1 pc., Blindfold seals: 2 sheets
Notes: 1) Where measurement conditions have not been specied precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) Typical value at 200 mm 7.874 in from directly in front of air outlet at the unit center at maximum fan speed.
3) Typical value at 300 mm 11.811 in from directly in front of air outlet at the unit center at maximum fan speed.
4) Please prepare an AC cable separately as it is needed.
The following cables are available as optionals:
CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KTL)
1179
Wide-area Ionizer ER-TF SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
Internal circuit
30 V DC or less
Tr
ZD
D
F
.G. terminal [connected internally to 0 V and COM (–).]
AC adapter (Accessory)
Error output
50 mA max.
5
4
6
2
3
Main circuit
Load
AC cable (Note)
+
COM (–)
+V
0 V
I/O circuit diagram
Symbols … D : Reverse supply polarity protection
diode
ZD : Surge absorption zener diode
Tr : NPN output transistor
Note: Please prepare an AC cable separately as it is needed.
The following cables are available as optionals:
CN-ACCN-C2: AC cable (conforming to CCC)
CN-ACKR-C2: AC cable (conforming to KTL)
I/O CIRCUIT AND WIRING DIAGRAMS
Terminal No. Terminal name
1
N.C. (no connection)
2
Error output
3
COM (–)
4
0 V
5
+V
6
F.G.
Terminal position
1
2
3
4
5
6
Charge removal time
Correlation between charge
removal distance and ion balance
Charge removal eld
(Horizontal direction)
Ion balance (Horizontal direction)
[Airow 4]
Measured using a 150 × 150 mm 5.906 × 5.906 in CPM (charge plate monitor). (At center of CPM)
ER-TF04-EX
ER-TF06-EX
Charge removal time
ER-TF08-EX
Correlation between charge
removal distance and ion balance
Charge removal eld
(Horizontal direction)
Ion balance (Horizontal direction)
[Airow 4]
Correlation between charge
removal distance and ion balance
Charge removal eld
(Horizontal direction)
Ion balance (Horizontal direction)
[Airow 4]
CHARGE REMOVAL CHARACTERISTICS (TYPICAL)
0
10
20
30
35
25
15
5
40
0
Airflow 1
Airflow 2
Airflow 3
Airflow 4
L
CPM
Center
Charge removal time (sec.)
Charge removal distance L (mm in)
200
7.874
400
15.748
600
23.622
800
31.496
1600
62.992
1400
55.118
1200
47.244
1000
39.370
0 200
7.874
400
15.748
600
23.622
800
31.496
1600
62.992
1400
55.118
1200
47.244
1000
39.370
Charge removal distance L (mm in)
0
Airflow 1
Airflow 2
Airflow 3
Airflow 4
L
CPM
Center
Ion balance (V)
30
20
10
10
20
30
200
7.874
400
15.748
600
23.622
800
31.496
1600
62.992
1400
55.118
1200
47.244
1000
39.370
0
Charge removal distance L (mm in)
-400
-15.748
-200
-7.874
0
200
7.874
300
11.811
100
3.937
-100
-3.937
-300
-11.811
400
15.748
LW
CPM
Center
+Direction
-Direction
Charge removal width W (mm in)
2 sec.(Airflow 2)
5 sec.(Airflow 2)
10 sec.(Airflow 2)
2 sec.(Airflow 4)
5 sec.(Airflow 4)
10 sec.(Airflow 4)
Ion balance (V)
30
20
10
10
20
30
Charge removal width W (mm in)
-400
-15.748
-300
-11.811
-200
-7.874
-100
-3.937
0 400
15.748
300
11.811
200
7.874
100
3.937
LW
CPM
Center +Direction
-Direction
0
L=300 mm 11.811 in
L=500 mm 19.685 in
L=1000 mm 39.370 in
Charge removal
distance L (mm in)
0
10
20
30
35
25
15
5
40
0
Airflow 1
Airflow 2
Airflow 3
Airflow 4
L
CPM
Center
Charge removal time (sec.)
Charge removal distance L (mm in)
200
7.874
400
15.748
600
23.622
800
31.496
1600
62.992
1400
55.118
1200
47.244
1000
39.370
0 200
7.874
400
15.748
600
23.622
800
31.496
1600
62.992
1400
55.118
1200
47.244
1000
39.370
Charge removal distance L (mm in)
0
Airflow 1
Airflow 2
Airflow 3
Airflow 4
L
CPM
Center
Ion balance (V)
30
20
10
10
20
30
200
7.874
400
15.748
600
23.622
800
31.496
1600
62.992
1400
55.118
1200
47.244
1000
39.370
0
Charge removal distance L (mm in)
-400
-15.748
-200
-7.874
0
200
7.874
300
11.811
100
3.937
-100
-3.937
-300
-11.811
400
15.748
LW
CPM
Center
+Direction
-Direction
Charge removal width W (mm in)
2 sec.(Airflow 2)
5 sec.(Airflow 2)
10 sec.(Airflow 2)
2 sec.(Airflow 4)
5 sec.(Airflow 4)
10 sec.(Airflow 4)
Ion balance (V)
30
20
10
10
20
30
Charge removal width W (mm in)
-400
-15.748
-300
-11.811
-200
-7.874
-100
-3.937
0 400
15.748
300
11.811
200
7.874
100
3.937
LW
CPM
Center +Direction
-Direction
0
L=300 mm 11.811 in
L=500 mm 19.685 in
L=1000 mm 39.370 in
Charge removal
distance L (mm in)
Charge removal time
0
10
20
30
35
25
15
5
40
0
Airflow 1
Airflow 2
Airflow 3
Airflow 4
L
CPM
Center
Charge removal time (sec.)
Charge removal distance L (mm in)
200
7.874
400
15.748
600
23.622
800
31.496
1600
62.992
1400
55.118
1200
47.244
1000
39.370
0 200
7.874
400
15.748
600
23.622
800
31.496
1600
62.992
1400
55.118
1200
47.244
1000
39.370
Charge removal distance L (mm in)
0
Airflow 1
Airflow 2
Airflow 3
Airflow 4
L
CPM
Center
Ion balance (V)
30
20
10
10
20
30
200
7.874
400
15.748
600
23.622
800
31.496
1600
62.992
1400
55.118
1200
47.244
1000
39.370
0
Charge removal distance L (mm in)
-400
-15.748
-200
-7.874
0
200
7.874
300
11.811
100
3.937
-100
-3.937
-300
-11.811
400
15.748
LW
CPM
Center
+Direction
-Direction
2 sec.(Airflow 2)
5 sec.(Airflow 2)
10 sec.(Airflow 2)
2 sec.(Airflow 4)
5 sec.(Airflow 4)
10 sec.(Airflow 4)
Charge removal width W (mm in)
Ion balance (V)
30
20
10
10
20
30
Charge removal width W (mm in)
-400
-15.748
-300
-11.811
-200
-7.874
-100
-3.937
0
400
15.748
300
11.811
200
7.874
100
3.937
LW
CPM
Center +Direction
-Direction
0
L=300 mm 11.811 in
L=500 mm 19.685 in
L=1000 mm 39.370 in
Charge removal
distance L (mm in)
Wide-area Ionizer ER-TF SERIES
1180
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
Mounting
100 mm
3.937 in
Air outlet
Air outlet
Forbidden zone Forbidden zone
Ionizer
45°
45°
100 mm
3.937 in
45° 45°
• Do not place any objects or any other charge removal
equipment within 100 mm 3.937 in of the ionized air
outlet front (refer to the illustration below), as they may
affect operation and performance of the ionizer.
Maintenance
• Always be sure to turn off the power before carrying out
any care and maintenance of the product.
• The tip of the discharge needle is sharp, so be careful not
to touch it while cleaning.
• When the product is used for long periods of time, dust
and other foreign particles may accumulate on the
discharge needle, the area around it, and on the fan lter.
Clean regularly (discharge needle: about once a week,
air lter: about once every two months), otherwise their
charge removal performance will drop and operating
problems or accidents may occur.
• The discharge needle is a consumable part. If the charge
removal performance is not restored after cleaning the
discharge needle, the discharge needle unit should be
replaced. All of the discharge needle units should be
replaced at the same time.
This product is to remove static electricity for industrial use. Never use this product for medical equipment etc.
relating to maintenance / supervision of human life or body, for prevention of accidents which damage a human
life or properties, or for safety maintenance.
Do not use this product near or around surroundings containing any dangerous materials, such as combustible
material and ammable material.
This product emits ozone. In order for this product to be used in an airtight room, be sure to keep the room ventilated.
Do not place any objects that may obstruct the inow of air within 10 mm 0.394 in of the front of the fan air intake
part. Doing so may cause accident or product malfunction.
Be sure to ground the main body of this product via ground terminal to ensure electrical shock prevention and
reliable charge removal.
Since the charge needle is applied with high voltage, never touch the discharge needle, or an electric shock may result.
Since the tip of the discharge needle is sharp, take sufcient care in handling the discharge needle, or injuries may result.
PRECAUTIONS FOR PROPER USE
61
2.402
80 3.150
45.3 1.784
8.3
0.327
G
E
4.5 0.177
47
1.850
F
D
Discharge needle holder Air outlet Power indicator (Green)
(4 0.158)
24
0.945
60
2.362
4-M5 (thru-hole)
4-M4 (thru-hole)
48
1.890
44 1.732
143
5.630
(50 1.969)
92.2 3.630
98 3.858
(100 3.937)
43.5
1.713
B
15.5 0.610 5.5
0.217
(A)
C
Error indicator (Red)
Check Indicator (Orange)
Air inlet
Mounting bracket
Power connector
Power switch
Fan status indicator (Yellow)
Discharger status indicator (Yellow)
Fan speed switch
12 0.472
Model No. A B C D E F G
ER-TF04-EX 414
16.299
240
9.449 351.5
13.839
290
11.417
190
7.480 255
10.039
120
4.724
ER-TF06-EX 574
22.598
400
15.748
511.5
20.138
450
17.717
350
13.780
400
15.748
280
11.024
ER-TF08-EX 734
28.898
560
22.047
671.5
26.437
610
24.016
510
20.079
560
22.047
440
17.323
DIMENSIONS (Unit: mm in)The CAD data can be downloaded from our website.
ER-TF□-EX Ionizer