SINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry Goods over a period of last 24 years. We supply to various industries including but not limited to Power generation plants, Cement Plants, Rolling mills, Railways, Rubber Factories, Textile Mills, Construction Equipment Manufacturers, Oil Refineries, Hospitals, Hotels and Corporate across the country along with a strong market presence in more than 10 countries including UAE, Saudi Arabia, India, Oman, US and Canada. We, at KMIC, assure our clients of committed deliveries and excellent post sales service. This way we believe we sell peace of mind and help our clients focus on their core business. Most of our clients in various industrial areas in India and Middle East have been associated with us for more than 10 years now. Our superior knowledge of products and focus on excellent relationships with clients remains our biggest strength and guiding force in our business. We have deep experience of working with big corporates in Oil & Gas and Construction sector in Middle East. We would be glad to have an association with you. For details, Visit us at Leading Exporters of: * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Control Panel Accessories Switchgears Contactors Relays MCBs Circuit Breakers Sensors Automation Drives Power Supplies Control Transformers DC Drives Frequency Converters PLCs Electric Motors Timers Rotary Switches Fuses Semiconductor Fuses Luminaires LED Lighting Power capacitors Indicating Lights Push buttons Wires and Cables Cable Lugs Cable Glands Energy Meters Motor Starters Motor Terminal Plates Slip rings All types of Carbons Holders and Brushes Generator Spares Ball Bearings www.kmindustrialcorp.com 3937/B Behind HDFC Bank, G.B. Road, Delhi (India)-110006 Contact: +91-9971138071, +91-11-23212528 | Email: atul.lakhotia@kmindustrialcorp.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com Tmax Molded case circuit breakers 15 T M ma CC x Bs Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high performance, versatility and standardization in a range of molded case circuit breakers. The ABB Tmax has been developed to complement the performance-proven Isomax line of circuit breakers. This new breaker, with a range up to 600A, has several very big features that go along with its very small size: * Double insulation - this construction characteristic allows for the UL Listed field installation of internal accessories without exposure to the power poles. * Positive operation - all molded case breakers from ABB ensure that the toggle indicates the precise position of the moving contacts. This guarantees safe and reliable signaling by the device. * Installation - Tmax Series can be installed in panels and switchboards in either the horizontal or vertical planes while being fed from either end without any derating of their performance characteristics. * Two ranges of accessories - in the pursuit of standardization, all Tmax internal and external accessories can be utilized across the entire range from 15A to 600A. * Interrupt ratings at 480VAC up to 150kAIC. * Compact size * UL Listed and IEC rated for global application and acceptance. The ABB Tmax has the performance and accessories to satisfy all industry requirements in the 600VAC to 600VDC ranges. A single pole molded case version is available for the first time. Frame sizes -- five basic sizes The ABB Tmax series includes five basic frame sizes as well as the T1 single pole with the range rated from 15A to 600A at 480VAC. The various versions carry the following interrupting capacities: * B Basic breaking capacity * N Normal breaking capacity * S Standard breaking capacity * H High breaking capacity * L Limiting capacity * V Very high breaking capacity Derived versions * T2, T4 & T5 circuit breakers with LS/I electronic trip units * Switch disconnectors in T1, T3, T4 and T5 frames * Circuit breakers for motor circuit protection (MCPs) * Circuit breakers for direct current ABB Tmax versions * Fixed: all models * Plug-in: T2, T3, T4 and T5 UL * UL File #E93565 (breakers and MCPs) #E116596 (Accessories) #E116595 (Molded case switches) Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 Contact us at: 15 +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com General information Circuit breakers for power distribution T1 - T3 ax s Tm CB C M T1 T2 T3 Tmax T1 1P Tmax T1 Tmax T2 Tmax T3 100 1 277 100 3, 4 600Y / 347V 500 N 50 2 100 3, 4 480 225 3, 4 600Y/347V 500 N S 50 65 UL 489 CSA C22.2 Frame size Number of poles Rated voltage A Nr V V AC (50-60 Hz) DC Interrupting ratings B AC 240 V 277 V 480 V 600Y/347 600 V DC 250 V - 2 poles in series 500 V - 3 poles in series 500 V - 2 poles in series 600 V - 3 poles in series TMF TMD/TMA ELT MA MCCB MCS MCP Trip units Versions kA kA kA kA kA kA kA kA kA S 65 H 100 35 65 18 1 22 2 10 25 25 25 10 35 10 25 25 35 35 L 120 85 75 50 10 85 100 250 3,4 690 500 N S 50 85 36 50 25 40 20 30 5 8 36 50 40 55 85 36 IEC 60947-2 Rated uninterrupted current, lu Number of poles Rated service voltage, Ue 15 AC (50-60 Hz) DC Rated ultimate short circuit breaking capacity, Icu AC (50-60 Hz) 220/230 V 380/415 V 440 V 500 V 690 V DC 250 V - 2 poles in series 250 V - 3 poles in series 500 V - 2 poles in series 500 V - 3 poles in series 750 V - 3 poles in series Trip units TMF TMD/TMA ELT MF MA A Nr V V kA kA kA kA kA kA kA kA kA kA 160 1 240 125 B 25 B 25 16 10 8 3 16 20 160 3,4 690 500 C 40 25 15 10 4 25 30 N 50 36 22 15 6 36 40 N 65 36 30 25 6 36 40 S 85 50 45 30 7 50 55 160 3,4 690 500 H 100 70 55 36 8 70 85 16 25 36 36 50 70 50 2.76/70 25,000 240 8000 120 5.12/130 3/76 4/102 2.76/70 25,000 240 8000 120 5.12/130 3.54/90 4.72/120 2.76/70 25,000 240 8000 120 5.9/150 4.13/105 5.51/140 2.76/70 25,000 240 8000 120 1.06 2.34 2.86 5.45 UL 489 CSA C22.2 and IEC 60947-2 Dimensions H W 1p or 3p W 4p D in/mm in/mm in/mm in/mm No. operations No. Hourly operations No. operations No. hourly operations Mechanical life Weights (Fixed 3P) Lbs. 5.12/130 1/25.4 1 In15A = 10kA @ 277 VAC 2 In15A = 35kA @ 240 VAC, 14 kA @ 480 VAC TMF = Thermomagnetic trip unit with fixed thermal and magnetic threshold TMD = Thermomagnetic trip unit with adjustable thermal threshold and fixed magnetic threshold. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com General information Circuit breakers for power distribution T4 - T5 T4 http://kmindustrialcorp.com 15 T M ma CC x Bs T5 Tmax T4 Tmax T5 UL 489 CSA C22.2 Frame size Number of poles Rated voltage AC (50-60 Hz) DC A Nr V V AC 240 V 277 V 480 V 600 V DC 250 V - 2 poles in series 500 V - 3 poles in series 500 V - 2 poles in series 600 V - 3 poles in series kA kA kA kA kA kA kA kA Interrupting ratings Trip units Versions 250 3, 4 600 600 N S H L V N S 65 100 150 200 200 65 100 600 3, 4 600 600 H L V 150 200 200 25 35 65 100 150 25 35 18 25 35 65 100 18 25 65 100 150 35 65 100 25 35 50 65 100 25 35 16 25 35 50 65 16 25 50 35 65 100 50 65 250 - 320 3, 4 690 750 S H L 85 100 200 50 70 120 40 65 100 30 50 85 25 40 70 50 70 120 400 - 630 3, 4 690 750 S H L 85 100 200 50 70 120 40 65 100 30 50 85 25 40 70 50 70 120 TMF TMD/TMA ELT MA MCCB MCS MCP IEC 60947-2 Rated uninterrupted current, lu Number of poles Rated service voltage, Ue AC (50-60 Hz) DC Rated ultimate short circuit breaking capacity, Icu AC (50-60 Hz) 220/230 V 380/415 V 440 V 500 V 690 V DC 250 V - 2 poles in series 250 V - 3 poles in series 500 V - 2 poles in series 500 V - 3 poles in series 750 V - 3 poles in series Trip units TMF TMD/TMA ELT MF MA A Nr V V kA kA kA kA kA kA kA kA kA kA N 70 36 30 25 20 36 V 300 200 180 150 80 200 N 70 36 30 25 20 36 15 V 300 200 180 150 80 200 25 36 50 70 100 25 36 50 70 100 16 25 36 50 36 50 70 16 25 70 UL 489 CSA C22.2 and IEC 60947-2 Dimensions Mechanical life Weights (Fixed 3P) H W 1p or 3p W 4p D in/mm in/mm in/mm in/mm No. operations No. Hourly operations No. operations No. hourly operations Lbs. 8.07/205 4.13/105 5.51/140 4.07/103.5 20,000 240 8000 (250A)-6000 (320A) 120 8.07/205 5.51/140 7.24/184 4.07/103.5 20,000 120 7000 (400A)-5000 (630A) 60 6.18 8.55 TMA = thermomagnetic trip unit with adjustable thermal and magnetic threshold MF = Magnetic fixed trip unit MA = Magnetic adjustable trip unit ELT = Electronic trip unit Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: 15 ax s Tm CB C M +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com General information Circuit breakers for specific applications in accordance with IEC 60947-2 T1 T2 Tmax T1 1P Tmax T1 380/415 VAC 440 VAC 690 VAC A Nr V kA rms kA rms kA rms kA rms 160 1 240 B 25 1 H W D in-mm in-mm in-mm 5.12 - 130 1 - 25.4 2.76 - 70 160 3, 4 690 B C N 16 25 36 10 15 22 3 4 6 100 100 50 5.12 - 130 3 - 76 2.76 - 70 T3 Tmax T2 Tmax T3 Circuit breakers for distribution AC-DC Rated uninterupted circuit Number of poles Rated voltage Ics/Icu @ 380/415 VAC % Dimensions fixed version (3p) AC 50-60 Hz 160 3, 4 690 N S H 36 50 70 30 45 55 6 7 8 100 100 100 5.12 - 130 3.54 - 90 2.76 - 70 L 85 75 10 75 225 3, 4 690 N S 36 50 25 40 5 8 75 50 5.0 - 150 4.13 - 105 2.76 - 70 Circuit breakers for motor protection Iu Poles In Ue Trip unit A 160 3 1 - 100 690 A V Adjustable magnetic only Electronic (6 - 12xin) PR221DS-I PR222/MP (IEC 60947-4-1) PR212/P-I PR212/MP (IEC 60947-4-1) 250 3 100 - 200 690 Switch-disconnectors 15 Poles Ith Ue Uimp Ui Icm Icw (1s) Nr A V kV V kA kA 3, 4 160 690 8 800 2.8 2 3, 4 250 690 8 800 5.3 3.6 1 For In 16A and In 20A: Icu @ 220/230 VAC = 16 kA Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 General information T M ma C Circuit breakers for specific applications in accordance CB x s with IEC 60947-2 T4 T5 Tmax T4 Tmax T5 Circuit breakers for distribution AC-DC Rated uninterrupted current Number of poles Rated voltage AC (50-60 Hz) Icu 380/415 VAC 440 VAC 480 V 690 VAC Ics/Icu @ 380/415 VAC Dimensions fixed version (3p) H W D A Nr V kA rms kA rms kA kA kA in-mm in-mm in-mm N S 36 50 30 40 20 25 20 25 100 100 250 3, 4 690 H L 70 120 65 100 40 70 40 70 100 100 V 200 180 80 80 100 400 - 630 3, 4 690 N S H L 36 50 70 120 30 40 65 100 20 25 40 70 20 25 40 70 100 100 100 100 8.07/205 4.13/105 4.07/103.5 8.07 - 205 5.51/140 4.07/103.5 250 3 80 - 250 690 400 3 320 - 400 690 3/4 250 - 320 690 8 800 5.3 3.6 3/4 400 - 630 690 8 800 5.3 6 V 200 180 80 80 100 Circuit breakers for motor protection Iu Poles In Ue Trip unit A V Adjustable magnetic only (6 - 12xin) Electronic PR221DS-I PR222/MP (IEC 60947-4-1) PR212P-I PR212/MP (IEC 60947-4-1) Switch-disconnectors Poles Ith Ue Uimp Ui Icm Icw (1s) Nr V kV V kA kA 1 For In 16A and In 20A: Icu @ 220/230 VAC = 16 kA Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 Contact us at: +91-9971138071; contactus@kmindustrialcorp.com 15 http://kmindustrialcorp.com General information Catalog number explanation ax s Tm CB C M T3 S 080 T W - 4 xxx Accessories (added in alpha-numeric order) 1 A = Auxiliary Switch S_ = Shunt trip with voltage code U_ = Undervoltage release with voltage code Number of poles -1 = 1 pole (T1 only) -4 = 4 pole None = 3 pole Type connectors W = None L = Lugs included Trip unit function B D T M E5 C E = = = = = = = LS/I (AC only) Molded Case Switch (MCS) Thermal-magnetic - 10X Mag Magnetic only (MCP) Electronic MCP (AC only) LSI (AC only) LSIG (AC only) Current rating 015 = 080 = 100 = 225 = 250 = 400 = 15 15A 80A 100A 225A 250A 400A Interrupting rating class B N S H L V = = = = = = Basic Normal Standard High Limiting Very high Frame size T1 = T2 = T3 = T4 = T5 = 100A 100A 225A 250A 600A 1 Consult ABB for factory installed accessories. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 T1 100A, 600Y/347 Standard thermal-magnetic T1 T M ma CC x Bs HxWxD 5.12" x 3.00" x 2.76" General The T1 breaker family ranges from 15 through 100 amperes. The T1 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection. Thermal overload protection is provided by heat sensitive bimetals. Short circuit protection for the breaker is accomplished using a precise magnetic coil. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected circuits. Versions The T1 frame is available in two versions: T = Thermal-magnetic, fixed D = Molded case switch Performance levels The T1 breaker has two performance levels available: B = 277V Single pole N = 600Y / 347V Three pole UL489 / CSA C22.2 Interrupting capacity (kA RMS) Voltage Continuous rating B (1 pole) N 240VAC 15 - 100A -- 50 1 277VAC 15A 20 - 100A 10 18 -- -- 480VAC 15A 20 - 100A -- -- 14 22 600Y/347VAC 15 - 100A -- 10 250VDC 2 pole series 15 - 100A -- 25 500VDC 3 pole series 15 - 100A -- 25 IEC-947 Interrupting capacity (kA RMS) Voltage Continuous rating B (1 pole) N 230V 15 - 100A 25 50 Number of poles 415V 15 - 100A -- 36 The UL/CSA version of the T1 is available in single, three and four pole versions. IEC versions of the T1 are also available with the same dimensions up to 160 amperes. 440V 15 - 100A -- 22 500V 15 - 100A -- 15 Accessory mounting 690V 15 - 100A -- 6 250VDC 2 pole series 15 - 100A -- 36 500VDC 3 pole series 15 - 100A -- 36 The T1 frame is double insulated allowing for UL/CSA factory or field installation of internal accessories. No extra control cables are required for field installation. Shunt trips or UVR's mount in the left cavity and auxiliary contacts with bell alarm mount in the right cavity. Reverse feeding All versions of the T1 family are suitable for reverse feed applications. Molded case switches UL489 switches include no overcurrent protection except for a high instantaneous trip mechanism for self protection. 1 In 15A 35kA @ 240VAC. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 Contact us at: 15 +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com T1 100A, 600Y/347 Standard thermal-magnetic ax s Tm CB C M T1N TMF Breaker IC at 480VAC 14kA T1N 22kA Magnetic trip 3 pole, 600Y/347VAC/500VDC catalog number 15A 1000A T1N015TL1 20A 25A 30A 40A 50A 60A 70A 80A 90A 100A 1000A 1000A 1000A 1000A 1500A 1500A 1500A 1500A 1500A 1500A T1N020TL T1N025TL T1N030TL T1N040TL T1N050TL T1N060TL T1N070TL T1N080TL T1N090TL T1N100TL Rating List price $ 402 402 402 402 402 402 402 479 479 479 479 T1B TMF -- Single pole Breaker IC at 277VAC 10kA T1B 18kA Magnetic trip 1 pole, 277VAC catalog number List price 15A 1000A T1B015TL-1 $ 230 20A 25A 30A 40A 50A 60A 70A 80A 90A 100A 1000A 1000A 1000A 1000A 1500A 1500A 1500A 1500A 1500A 1500A T1B020TL-1 T1B025TL-1 T1B030TL-1 T1B040TL-1 T1B050TL-1 T1B060TL-1 T1B070TL-1 T1B080TL-1 T1B090TL-1 T1B100TL-1 230 230 230 230 230 230 262 262 262 262 Magnetic trip 480VAC/500VDC catalog number Rating T1N-D -- Molded case switch Breaker T1-D Interrupting capacity 2 240V, 50kA Rating 100A 1000A T1N100DL List price $ 431 T1N TMF -- 100% Rated standard thermal-magnetic Breaker IC at 480VAC 14kA 15 T1N 22kA Rating 15 1 20 25 30 40 50 60 70 80 90 100 Magnetic trip 3 pole 600Y/347 500VDC catalog number 1000A 1000A 1000A 1000A 1000A 1500A 1500A 1500A 1500A 1500A 1500A T1NQ015TL T1NQ020TL T1NQ025TL T1NQ030TL T1NQ040TL T1NQ050TL T1NQ060TL T1NQ070TL T1NQ080TL T1NQ090TL T1NQ100TL List price $ 442 527 1 Rated 277/480Y for 15A. 2 With fuse or MCCB protected circuit. Discount schedule S1T Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 T2 100A, 480V Thermal-magnetic/electronic T2 T M ma CC x Bs HxWxD 5.12" x 3.54" x 2.76" General The T2 breaker family ranges from 10 through 100 amperes. The T2 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection as well as a version with microprocessor-based electronic trip unit. Thermal overload protection is provided by heat sensitive bimetals. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected circuits. Versions The T2 frame is available in four versions: T = Thermal-magnetic, fixed B = Adjustable LS/I electronic M = Magnetic only (MCP) E5 = Electronic instantaneous only (MCP) Trip functions These tripping functions are available: L = Long time S = Short time I - Instantaneous UL489 / CSA C22.2 Interrupting capacity (kA RMS) Voltage Continuous rating S H 240VAC 15 - 100A 65 100 480VAC 15 - 100A 35 65 IEC-947 Interrupting capacity (kA RMS) Voltage Continuous rating S H 230V 15 - 100A 85 100 415V 15 - 100A 50 70 440V 15 - 100A 45 55 500V 15 - 100A 30 36 690V 15 - 100A 7 8 250VDC 2 pole series 15 - 100A 50 70 500VDC 3 pole series 15 - 100A 50 70 Performance levels The T2 breaker has two performance levels available: S = Standard H = High Number of poles The UL/CSA version of the T2 is available in three and four pole versions. IEC versions of the T2 are also available with the same dimensions up to 160 amperes. Accessory mounting The T2 frame is double insulated allowing for UL/CSA factory or field installation of internal accessories. No extra control cables are required for field installation. Shunt trips or UVR's mount in the left cavity and auxiliary contacts with bell alarm mount in the right cavity. Reverse feeding All versions of the T2 family are suitable for reverse feed applications. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 Contact us at: 15 +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com T2 100A, 480V Thermal-magnetic/electronic ax s Tm CB C M T2 -- 100A TMF IC at 480VAC Rating Magnetic trip 3 pole, 480VAC catalog number List price T2S 35kA 15A 20A 25A 30A 40A 50A 60A 70A 80A 90A 100A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A T2S015TW T2S020TW T2S025TW T2S030TW T2S040TW T2S050TW T2S060TW T2S070TW T2S080TW T2S090TW T2S100TW $ 690 690 690 690 690 690 690 793 793 793 793 Breaker IC at 480VAC Rating Magnetic trip 65kA 15A 20A 25A 30A 40A 50A 60A 70A 80A 90A 100A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A Breaker T2H 3 pole, 480VAC catalog number T2H015TW T2H020TW T2H025TW T2H030TW T2H040TW T2H050TW T2H060TW T2H070TW T2H080TW T2H090TW T2H100TW List price $ 942 942 942 942 942 942 942 1153 1153 1153 1153 T2 -- 100A frame electronic trip unit (AC only) Breaker IC at 480VAC T2S 35kA T2H 65kA Trip unit type CT rating 3 pole, 480VAC catalog number List price PR221DS-LS/I 25A 60A 100A T2S025BW T2S060BW T2S100BW $ 1240 1240 1343 PR221DS-LS/I 25A 60A 100A T2H025BW T2H060BW T2H100BW 1492 1492 1703 T2 -- 100A frame magnetic only (MCP) 15 Breaker IC at 480VAC Trip unit type Rating Adjustment range 3 pole, 480VAC catalog number List price T2S 35kA Mag only 20A 50A 100A 120 - 240 300 - 600 600 - 1200 T2S020MW T2S050MW T2S100MW $ 598 670 804 T2H 65kA Mag only 20A 50A 100A 120 - 240 300 - 600 600 - 1200 T2H020MW T2H050MW T2H100MW 673 754 904 Rating Adjustment range 3 pole, 480VAC catalog number List price T2 -- 100A frame instantaneous only, electronic (MCP - AC only) Breaker IC at 480VAC Trip unit type T2S 35kA Instantaneous only 25A 60A 100A 25 - 250 60 - 600 100 - 1000 T2S025E5W T2S060E5W T2S100E5W $ 1178 1178 1276 T2H 65kA Instantaneous only 25A 60A 100A 25 - 250 60 - 600 100 - 1000 T2H025E5W T2H060E5W T2H100E5W 1417 1417 1618 Discount schedule S2T Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 T2 100A, 480V, 100% rated Thermal-magnetic/electronic T M ma CC x Bs T2 - 100A TMF, 100% rated Breaker T2S Breaker T2H IC at 480VAC 35kA IC at 480VAC 65kA Rating Magnetic trip 3 pole, 480VAC catalog number List price 15A 20A 25A 30A 40A 50A 60A 500A 500A 500A 500A 500A 500A 600A T2SQ015TW T2SQ020TW T2SQ025TW T2SQ030TW T2SQ040TW T2SQ050TW T2SQ060TW $ 760 70A 80A 90A 100A 700A 800A 900A 1000A T2SQ070TW T2SQ080TW T2SQ090TW T2SQ100TW 872 Rating Magnetic trip 3 pole, 480VAC catalog number List price 15A 20A 25A 30A 40A 50A 60A 500A 500A 500A 500A 500A 500A 600A T2HQ015TW T2HQ020TW T2HQ025TW T2HQ030TW T2HQ040TW T2HQ050TW T2HQ060TW $ 1025 70A 80A 90A 100A 700A 800A 900A 1000A T2HQ070TW T2HQ080TW T2HQ090TW T2HQ100TW 1268 CT rating 3 pole, 480VAC catalog number List price 25A 60A T2SQ025BW T2SQ060BW $ 1363 100A T2SQ100BW 1477 25A 60A T2HQ025BW T2HQ060BW 1640 100A T2HQ100BW 1873 T2 - 100A frame electronic trip unit (AC only) Breaker IC at 480VAC T2S 35kA T2H 65kA Trip unit type PR221DS-LS/I PR221DS-LS/I 15 Discount schedule S2T Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: 15 ax s Tm CB C M +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com T3 600Y/347V Thermal-magnetic T3 HxWxD 5.9" x 4.13" x 2.76" General The T3 breaker family ranges from 60 through 225 amperes. The T3 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection. Thermal overload protection is provided by heat sensitive bimetals. Short circuit protection begins at 10 times the thermal rating of the breaker using a precise magnetic coil. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected circuits. Versions The T3 frame is available in three versions: T = Thermal-magnetic, fixed M = Magnetic only (MCP) D = Molded case switch Performance levels The T3 breaker has two performance levels available: N = Normal S = Standard Number of poles The UL/CSA version of the T3 is available in three and four pole versions. IEC versions of the T3 are also available with the same dimensions up to 250 amperes. UL489 / CSA C22.2 Interrupting capacity (kA RMS) Voltage Continuous rating N S 240VAC 60 - 225A 50 65 480VAC 60 - 225A 25 35 600Y/347VAC 60 - 225A 10 10 250VDC 2 pole series 60 - 225A 25 35 500VDC 3 pole series 60 - 225A 25 35 IEC-947 Interrupting capacity (kA RMS) Voltage Continuous rating N S 230V 60 - 225A 50 85 415V 60 - 225A 36 50 440V 60 - 225A 25 40 500V 60 - 225A 20 30 690V 60 - 225A 5 8 250VDC 2 pole series 60 - 225A 36 50 500VDC 3 pole series 60 - 225A 36 50 Accessory mounting 15 The T3 frame is double insulated allowing for UL/CSA factory or field installation of internal accessories. No extra control cables are required for field installation. Shunt trips or UVR's mount in the left cavity and auxiliary contacts with bell alarm mount in the right cavity. Reverse feeding All versions of the T3 family are suitable for reverse feed applications. Molded case switches UL489 switches include no overcurrent protection except for a high instantaneous trip mechanism for self protection. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 T3 225A, 600Y/347V Thermal-magnetic trip units T M ma CC x Bs T3 -- 225A Frame TMF Breaker IC at 480VAC T3N 25kA Breaker IC at 480VAC T3S 35kA Rating 60A 70A 80A 90A 100A 125A 150A 175A 200A 225A Rating 60A 70A 80A 90A 100A 125A 150A 175A 200A 225A Magnetic trip 3 pole, 480VAC/500VDC catalog number 600A 700A 800A 900A 1000A 1250A 1500A 1750A 2000A 2250A T3N060TW T3N070TW T3N080TW T3N090TW T3N100TW T3N125TW T3N150TW T3N175TW T3N200TW T3N225TW Magnetic trip 3 pole, 480VAC/500VDC catalog number 600A 700A 800A 900A 1000A 1250A 1500A 1750A 2000A 2250A T3S060TW T3S070TW T3S080TW T3S090TW T3S100TW T3S125TW T3S150TW T3S175TW T3S200TW T3S225TW List price $ 615 740 740 740 740 1560 1560 1560 1560 1560 List price $ 790 970 970 970 970 2160 2160 2160 2160 2160 T3 -- 225A frame magnetic only, (MCP) Breaker IC at 480VAC T3S 35kA Trip unit type Rating Adjustment range Mag only 100A 125A 150A 200A 600 - 1200 750 - 1500 900 - 1800 1200 - 2400 3 pole, 480VAC catalog number List price T3S100MW T3S125MW T3S150MW T3S200MW $ 1074 1108 1299 1382 T3S-D -- Molded case switch Breaker Interrupting 1 capacity T3S-D 240V, 65kA 480V, 35kA Rating 150A 225A Magnetic trip 1500A 2250A 3 pole, 480VAC/500VDC catalog number T3S150DW T3S225DW List price $ 1078 1515 15 1 With fuse or MCCB protected circuit. Discount schedule S3T Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: 15 +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com T3 225A, 600Y/347V, 100% rated Thermal-magnetic trip units ax s Tm CB C M T3 - 225A Frame TMF, 100% rated Breaker T3N Breaker T3S IC at 480VAC 25kA IC at 480VAC 35kA Rating Magnetic trip 3 pole, 600/347V VAC/500VDC catalog number List price 60A 600A T3NQ060TW $ 656 70A 80A 90A 100A 700A 800A 900A 1000A T3NQ070TW T3NQ080TW T3NQ090TW T3NQ100TW 812 125A 150A 175A 200A 225A 1250A 1500A 1750A 2000A 2250A T3NQ125TW T3NQ150TW T3NQ175TW T3NQ200TW T3NQ225TW 1717 Magnetic trip 3 pole, 600/347VVAC/500VDC catalog number 60A 600A T3SQ060TW $ 778 70A 80A 90A 100A 700A 800A 900A 1000A T3SQ070TW T3SQ080TW T3SQ090TW T3SQ100TW 1065 125A 150A 175A 200A 225A 1250A 1500A 1750A 2000A 2250A T3SQ125TW T3SQ150TW T3SQ175TW T3SQ200TW T3SQ225TW 2399 Rating List price 15 1 With fuse or MCCB protected circuit. Discount schedule S3T Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 T4 250A, 600V Electronic and thermal magnetic trip units T3 T M ma CC x Bs HxWxD 8.07" x 4.13" x 4.07" General The T4 breaker is a 250 amp frame with either a microprocessor based over current protective trip system or a thermal magnetic trip unit. As an electronic breaker, the T4 is available in 100A, 150A and 250A frames. The T4 is available as a thermal magnetic unit from 20A to 250A. UL489 / CSA C22.2 Interrupting capacity (kA RMS) Voltage N S H L V 240VAC 65 100 150 200 200 480VAC 25 35 65 100 150 Versions 600VAC 18 25 35 65 100 To meet all application requirements, the T4 is available in the following versions: T = Thermal-magnetic, fixed B = Selectable & adjustable LI or LS C = Adjustable LSI E = Adjustable LSIG D = Molded Case Switch E5 = Electronic instantaneous only (MCP) 500VDC 1 25 35 50 65 100 600VDC 2 16 25 35 50 65 IEC-947 Interrupting capacity (kA RMS) Voltage N S H L V 230VAC 70 85 100 200 300 Trip functions 415VAC 36 50 70 120 200 These trip functions are available: L = Long time S = Short time I = Instantaneous G = Ground fault 440VAC 30 40 65 100 180 500VDC 25 30 50 85 150 690VDC 20 25 40 70 80 Performance levels Each version is also available in different maximum fault interrrupting levels: N = Normal S = Standard H = High L = Extra high V = Very high Number of poles The T4 is available as a 3 and 4 pole breaker. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. Accessory mounting Internal accessories are UL/CSA approved for both factory and field installation. No extra control connectors are required for field connection. Shunt trips and UVRs mount in the left cavity and auxiliary contacts and bell alarms mount in the right cavity. Reverse feeding All versions of the T4 family are suitable for reverse feed applications. 1 2 poles in series. 2 3 poles in series. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 Contact us at: +91-9971138071; contactus@kmindustrialcorp.com 15 http://kmindustrialcorp.com T4 250A, 600V Electronic trip units (AC only) ax s Tm CB C M 100A Frame (40 - 100A adjustable range) Breaker Ic at 480VAC kA Trip Unit 3 Pole, 600V Catalog number List price T4N 25 PR221 LS/I PR222 LSI PR222 LSIG T4N100BW T4N100CW T4N100EW $ 1903 2540 3330 T4S 35 PR221 LS/I PR222 LSI PR222 LSIG T4S100BW T4S100CW T4S100EW 2370 3164 4148 T4H 65 PR221 LS/I PR222 LSI PR222 LSIG T4H100BW T4H100CW T4H100EW 4498 4845 5877 T4L 100 PR221 LS/I PR222 LSI PR222 LSIG T4L100BW T4L100CW T4L100EW 5954 6063 7091 T4V 150 PR221 LS/I PR222 LSI PR222 LSIG T4V100BW T4V100CW T4V100EW 8555 9213 9957 3 Pole, 600V Catalog number List price 150A Frame (60 - 150A adjustable range) Breaker Ic at 480VAC kA Trip Unit T4N 25 PR221 LS/I PR222 LSI PR222 LSIG T4N150BW T4N150CW T4N150EW $ 2050 2737 3588 T4S 35 PR221 LS/I PR222 LSI PR222 LSIG T4S150BW T4S150CW T4S150EW 2542 3394 4449 T4H 65 PR221 LS/I PR222 LSI PR222 LSIG T4H150BW T4H150CW T4H150EW 4633 5024 6094 T4L 100 PR221 LS/I PR222 LSI PR222 LSIG T4L150BW T4L150CW T4L150EW 6174 6288 7354 T4V 150 PR221 LS/I PR222 LSI PR222 LSIG T4V150BW T4V150CW T4V150EW 8872 9555 10,326 15 250A Frame (100 - 250A adjustable range) Breaker Ic at 480VAC kA Trip Unit 3 Pole, 600V Catalog number List price T4N 25 PR221 LS/I PR222 LSI PR222 LSIG T4N250BW T4N250CW T4N250EW $ 2112 2819 3696 T4S 35 PR221 LS/I PR222 LSI PR222 LSIG T4S250BW T4S250CW T4S250EW 2573 3435 4503 T4H 65 PR221 LS/I PR222 LSI PR222 LSIG T4H250BW T4H250CW T4H250EW 4713 5127 6219 T4L 100 PR221 LS/I PR222 LSI PR222 LSIG T4L250BW T4L250CW T4L250EW 6300 6416 7504 T4V 150 PR221 LS/I PR222 LSI PR222 LSIG T4V250BW T4V250CW T4V250EW 9053 9750 10,537 Discount schedule S4T Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 T4 250A, 600V Thermal magnetic trip units T M ma CC x Bs 20A - 250A Frame Breaker IC at 480VAC kA T4N Rating 25 T4S 35 T4H 65 T4L 100 T4V 150 Magnetic trip 3 pole, 600VAC/600VDC Catalog number List price 20A 30A 40A 50A 80A 100A 125A 150A 200A 250A 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 T4N020TW T4N030TW T4N040TW T4N050TW T4N080TW T4N100TW T4N125TW T4N150TW T4N200TW T4N250TW $ 1517 1517 1517 1517 1547 1547 1667 1667 1667 1717 20A 30A 40A 50A 80A 100A 125A 150A 200A 250A 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 T4S020TW T4S030TW T4S040TW T4S050TW T4S080TW T4S100TW T4S125TW T4S150TW T4S200TW T4S250TW 1887 1887 1887 1887 1927 1927 2067 2067 2067 2092 20A 30A 40A 50A 80A 100A 125A 150A 200A 250A 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 T4H020TW T4H030TW T4H040TW T4H050TW T4H080TW T4H100TW T4H125TW T4H150TW T4H200TW T4H250TW 3617 3617 3617 3617 3657 3657 3767 3767 3767 3832 20A 30A 40A 50A 80A 100A 125A 150A 200A 250A 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 T4L020TW T4L030TW T4L040TW T4L050TW T4L080TW T4L100TW T4L125TW T4L150TW T4L200TW T4L250TW 5915 5915 5915 5915 5965 5965 5995 5995 5995 6110 20A 30A 40A 50A 80A 100A 125A 150A 200A 250A 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 T4V020TW T4V030TW T4V040TW T4V050TW T4V080TW T4V100TW T4V125TW T4V150TW T4V200TW T4V250TW 6780 6780 6780 6780 6817 6817 6847 6847 6847 6887 Molded case switch Type Amps Magnetic trip 3 Pole, 600V Catalog number List price T4H-D T4L-D T4V-D 250 250 250 3000 3000 3000 T4H250DW T4L250DW T4V250DW $ 2154 3419 3842 Discount schedule S4T Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 Contact us at: +91-9971138071; contactus@kmindustrialcorp.com 15 http://kmindustrialcorp.com T4 250A, 600V, 100% Rated Electronic trip units (AC only) ax s Tm CB C M 100A Frame (40 - 100A adjustable range) Breaker Ic at 480VAC kA Trip Unit 3 Pole, 600V Catalog number List price T4N 25 PR221 LS/I PR222 LSI PR222 LSIG T4NQ100BW T4NQ100CW T4NQ100EW $ 2124 2835 3716 T4S 35 PR221 LS/I PR222 LSI PR222 LSIG T4SQ100BW T4SQ100CW T4SQ100EW 2645 3531 4629 T4H 65 PR221 LS/I PR222 LSI PR222 LSIG T4HQ100BW T4HQ100CW T4HQ100EW 5020 5383 6530 T4L 100 PR221 LS/I PR222 LSI PR222 LSIG T4LQ100BW T4LQ100CW T4LQ100EW 6616 6737 7879 T4V 150 PR221 LS/I PR222 LSI PR222 LSIG T4VQ100BW T4VQ100CW T4VQ100EW 9506 10,237 11,063 150A Frame (60 - 150A adjustable range) Breaker Ic at 480VAC kA Trip Unit 3 Pole, 600V Catalog number List price T4N 25 PR221 LS/I PR222 LSI PR222 LSIG T4NQ150BW T4NQ150CW T4NQ150EW $ 2288 3055 4004 T4S 35 PR221 LS/I PR222 LSI PR222 LSIG T4SQ150BW T4SQ150CW T4SQ150EW 2837 3788 4965 T4H 65 PR221 LS/I PR222 LSI PR222 LSIG T4HQ150BW T4HQ150CW T4HQ150EW 5171 5582 6771 T4L 100 PR221 LS/I PR222 LSI PR222 LSIG T4LQ150BW T4LQ150CW T4LQ150EW 6860 6987 8171 T4V 150 PR221 LS/I PR222 LSI PR222 LSIG T4VQ150BW T4VQ150CW T4VQ150EW 9858 10,616 11,473 15 250A Frame (100 - 250A adjustable range) Breaker Ic at 480VAC kA Trip Unit 3 Pole, 600V Catalog number List price T4N 25 PR221 LS/I PR222 LSI PR222 LSIG T4NQ250BW T4NQ250CW T4NQ250EW $ 2357 3146 4125 T4S 35 PR221 LS/I PR222 LSI PR222 LSIG T4SQ250BW T4SQ250CW T4SQ250EW 2872 3834 5025 T4H 65 PR221 LS/I PR222 LSI PR222 LSIG T4HQ250BW T4HQ250CW T4HQ250EW 5260 5697 6910 T4L 100 PR221 LS/I PR222 LSI PR222 LSIG T4LQ250BW T4LQ250CW T4LQ250EW 7000 7129 8338 T4V 150 PR221 LS/I PR222 LSI PR222 LSIG T4VQ250BW T4VQ250CW T4VQ250EW 10,058 10,833 11,708 Discount schedule S4T Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com T4 250A, 600V, 100% rated thermal-magnetic trip units Magnetic only MCPs 15 T M ma CC x Bs 30A - 250A Frame Breaker IC at 480 VAC kA T4N 25 T4S 35 T4H 65 T4L 100 T4V 150 Magnetic trip 3 pole, 600VAC/600VDC Catalog number List price 20A 30A 40A 50A 80A 100A 125A 150A 200A 250A 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 T4NQ020TW T4NQ030TW T4NQ040TW T4NQ050TW T4NQ080TW T4NQ100TW T4NQ125TW T4NQ150TW T4NQ200TW T4NQ250TW $ 1673 1673 1673 1673 1706 1706 1839 1839 1839 1894 20A 30A 40A 50A 80A 100A 125A 150A 200A 250A 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 T4SQ020TW T4SQ030TW T4SQ040TW T4SQ050TW T4SQ080TW T4SQ100TW T4SQ125TW T4SQ150TW T4SQ200TW T4SQ250TW 2081 2081 2081 2081 2125 2125 2280 2280 2280 2307 20A 30A 40A 50A 80A 100A 125A 150A 200A 250A 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 T4HQ020TW T4HQ030TW T4HQ040TW T4HQ050TW T4HQ080TW T4HQ100TW T4HQ125TW T4HQ150TW T4HQ200TW T4HQ250TW 3990 3990 3990 3990 4034 4034 4155 4155 4155 4227 20A 30A 40A 50A 80A 100A 125A 150A 200A 250A 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 T4LQ020TW T4LQ030TW T4LQ040TW T4LQ050TW T4LQ080TW T4LQ100TW T4LQ125TW T4LQ150TW T4LQ200TW T4LQ250TW 6524 6524 6524 6524 6579 6579 6612 6612 6612 6739 20A 30A 40A 50A 80A 100A 125A 150A 200A 250A 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 T4VQ020TW T4VQ030TW T4VQ040TW T4VQ050TW T4VQ080TW T4VQ100TW T4VQ125TW T4VQ150TW T4VQ200TW T4VQ250TW 7478 7478 7478 7478 7519 7519 7552 7552 7552 7569 Rating Magnetic-only MCPs T4 - 250A Frame magnetic only (MCP - AC only) Breaker IC at 480VAC Trip unit type Rating Adjustment range 3 pole, 600VAC Catalog number T4N 25kA Instantaneous only T4S 35kA Instantaneous only T4H 65kA T4L 100kA List price 100A 150A 250A 100A 150A 250A 100-1000 150-1500 250-2500 100-1000 150-1500 250-2500 T4N100E5W T4N150E5W T4N250E5W T4S100E5W T4S150E5W T4S250E5W $ 1808 1948 2006 2252 2415 2444 Instantaneous only 100A 150A 250A 100-1000 150-1500 250-2500 T4H100E5W T4H150E5W T4H250E5W 4273 4401 4477 Instantaneous only 100A 150A 250A 100-1000 150-1500 250-2500 T4L100E5W T4L150E5W T4L250E5W 5656 5865 5985 Discount schedule S4T Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 Contact us at: 15 ax s Tm CB C M T5 +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com T5 600A, 600V Electronic and thermal magnetic trip units HxWxD 8.07" x 5.51" x 4.07" General The T5 breaker is a 600 amp frame with either a microprocessor based over current protective trip system or a thermal magnetic trip unit. As an electronic breaker, the T5 is available in 300A, 400A and 600A frames. The T5 is available as a thermal magnetic unit of 300A or 400A. UL489 / CSA C22.2 Interrupting capacity (kA RMS) Voltage N S H L V 240VAC 65 100 150 200 200 480VAC 25 35 65 100 150 Versions 600VAC 18 25 35 65 100 To meet all application requirements, the T5 is available in the following versions: T = Thermal-magnetic B = Selectable & adjustable LI or LS C = Adjustable LSI E = Adjustable LSIG D = Molded Case Switch E5 = Electronic instantaneous only (MCP) 500VDC 1 25 35 50 65 100 600VDC 2 16 25 35 50 65 IEC-947 Interrupting capacity (kA RMS) Voltage N S H L V 230VAC 70 85 100 200 300 Trip functions 415VAC 36 50 70 120 200 These trip functions are available: L = Long time S = Short time I = Instantaneous G = Ground fault 440VAC 30 40 65 100 180 500VDC 25 30 50 85 150 690VDC 20 25 40 70 80 Performance levels Each version is also available in different maximum fault interrrupting levels: 15 N = Normal S = Standard H = High L = Extra high V = Very high Number of poles The T5 is available as a 3 and 4 pole breaker. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. Accessory mounting Internal accessories are UL/CSA approved for both factory and field installation. No extra control connectors are required for field connection. Shunt trips and UVRs mount in the left cavity and auxiliary contacts and bell alarms mount in the right cavity. Reverse feeding All versions of the T5 family are suitable for reverse feed applications. 1 2 poles in series. 2 3 poles in series. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 T5 600A, 600V Electronic trip units (AC only) T M ma CC x Bs 300A Frame Breaker Ic at 480VAC kA Trip Unit 3 Pole, 600V Catalog number List price T5N 25 PR221 LS/I PR222 LSI PR222 LSIG T5N300BW T5N300CW T5N300EW $ 3260 3865 4965 T5S 35 PR221 LS/I PR222 LSI PR222 LSIG T5S300BW T5S300CW T5S300EW 3350 3945 5138 T5H 65 PR221 LS/I PR222 LSI PR222 LSIG T5H300BW T5H300CW T5H300EW 5395 5893 7148 T5L 100 PR221 LS/I PR222 LSI PR222 LSIG T5L300BW T5L300CW T5L300EW 6860 7375 8625 T5V 150 PR221 LS/I PR222 LSI PR222 LSIG T5V300BW T5V300CW T5V300EW 10,406 11,206 12,111 Breaker Ic at 480VAC kA Trip Unit T5N 25 PR221 LS/I PR222 LSI PR222 LSIG T5N400BW T5N400CW T5N400EW $ 3260 3865 4965 T5S 35 PR221 LS/I PR222 LSI PR222 LSIG T5S400BW T5S400CW T5S400EW 3350 3945 5138 T5H 65 PR221 LS/I PR222 LSI PR222 LSIG T5H400BW T5H400CW T5H400EW 5395 5893 7148 T5L 100 PR221 LS/I PR222 LSI PR222 LSIG T5L400BW T5L400CW T5L400EW 6860 7375 8625 T5V 150 PR221 LS/I PR222 LSI PR222 LSIG T5V400BW T5V400CW T5V400EW 10,406 11,206 12,111 400A Frame 3 Pole, 600V Catalog number List price 15 600A Frame Breaker Ic at 480VAC kA Trip Unit 3 Pole, 600V Catalog number List price T5N 25 PR221 LS/I PR222 LSI PR222 LSIG T5N600BW T5N600CW T5N600EW $ 5750 6460 8360 T5S 35 PR221 LS/I PR222 LSI PR222 LSIG T5S600BW T5S600CW T5S600EW 5910 6595 8645 T5H 65 PR221 LS/I PR222 LSI PR222 LSIG T5H600BW T5H600CW T5H600EW 8170 8805 10,890 T5L 100 PR221 LS/I PR222 LSI PR222 LSIG T5L600BW T5L600CW T5L600EW 9860 10,440 12,630 T5V 150 PR221 LS/I PR222 LSI PR222 LSIG T5V600BW T5V600CW T5V600EW 13,550 14,375 16,350 Discount schedule S5T Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: 15 +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com T5 400A, 600V Thermal magnetic trip units 1 ax s Tm CB C M 300A - 400A Frames Breaker IC at 480VAC kA T5N 25 300A 400A 1500-3000 2000-4000 T5N300TW T5N400TW $ 2612 T5S 35 300A 400A 1500-3000 2000-4000 T5S300TW T5S400TW 2880 T5H 65 300A 400A 1500-3000 2000-4000 T5H300TW T5H400TW 4950 T5L 100 300A 400A 1500-3000 2000-4000 T5L300TW T5L400TW 6400 150 300A 400A 1500-3000 2000-4000 T5V300TW T5V400TW 9873 T5V Rating Magnetic trip 3 pole, 600VAC/600VDC Catalog number List price Molded case switch Type Amps Magnetic trip 3 Pole, 600V Catalog number List price T5H-D T5H-D T5L-D T5V-D 400 600 600 600 5000 6000 6000 6000 T5H400DW T5H600DW T5L600DW T5V600DW $ 4585 6550 8350 11,575 15 1 600A not available with thermal magnetic trip unit. Discount schedule S5T Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 T5 400A, 600V, 100% Rated 1 T M ma CC x Bs Electronic trip units (AC only) 300A Frame Breaker Ic at 480VAC kA Trip Unit 3 Pole, 600V Catalog number List price T5N 25 PR221 LS/I PR222 LSI PR222 LSIG T5NQ300BW T5NQ300CW T5NQ300EW $ 3628 4302 5526 T5S 35 PR221 LS/I PR222 LSI PR222 LSIG T5SQ300BW T5SQ300CW T5SQ300EW 3729 4391 5719 T5H 65 PR221 LS/I PR222 LSI PR222 LSIG T5HQ300BW T5HQ300CW T5HQ300EW 6005 6559 7956 T5L 100 PR221 LS/I PR222 LSI PR222 LSIG T5LQ300BW T5LQ300CW T5LQ300EW 7635 8208 9600 T5V 150 PR221 LS/I PR222 LSI PR222 LSIG T5VQ300BW T5VQ300CW T5VQ300EW 11,582 12,473 13,480 Breaker Ic at 480VAC kA Trip Unit 3 Pole, 600V Catalog number List price T5N 25 PR221 LS/I PR222 LSI PR222 LSIG T5NQ400BW T5NQ400CW T5NQ400EW $ 3628 4302 5526 T5S 35 PR221 LS/I PR222 LSI PR222 LSIG T5SQ400BW T5SQ400CW T5SQ400EW 3729 4391 5719 T5H 65 PR221 LS/I PR222 LSI PR222 LSIG T5HQ400BW T5HQ400CW T5HQ400EW 6005 6559 7956 T5L 100 PR221 LS/I PR222 LSI PR222 LSIG T5LQ400BW T5LQ400CW T5LQ400EW 7635 8208 9600 T5V 150 PR221 LS/I PR222 LSI PR222 LSIG T5VQ400BW T5VQ400CW T5VQ400EW 11,582 12,473 13,480 400A Frame 15 Thermal magnetic trip units 300A - 400A Frames Breaker IC at 480VAC kA Magnetic trip 3 pole, 600VAC/600VDC Catalog number List price T5N 25 300A 400A 1500-3000 2000-4000 T5NQ300TW T5NQ400TW $ 2888 T5S 35 300A 400A 1500-3000 2000-4000 T5SQ300TW T5SQ400TW 3185 T5H 65 300A 400A 1500-3000 2000-4000 T5HQ300TW T5HQ400TW 5475 T5L 100 300A 400A 1500-3000 2000-4000 T5LQ300TW T5LQ400TW 7078 T5V 150 300A 400A 1500-3000 2000-4000 T5VQ300TW T5VQ400TW 10,920 Rating 1 600A not available in 100% rated frame. Discount schedule S5T Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: 15 +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com T5 400A, 600V 1 Magnetic only, MCP ax s Tm CB C M T5 - 400A Frame magnetic only (MCP - AC only) Breaker IC at 480VAC Trip unit type Rating Adjustment range 3 pole, 600VAC Catalog number List price T5N 25kA Instantaneous only $ 3097 T5S 35kA 300-3000 400-4000 300-3000 400-4000 T5N300E5W T5N400E5W Instantaneous only 300A 400A 300A 400A T5S300E5W T5S400E5W 3183 T5H 65kA Instantaneous only 300A 400A 300-3000 400-4000 T5H300E5W T5H400E5W 5125 T5L 100kA Instantaneous only 300A 400A 300-3000 400-4000 T5L300E5W T5L400E5W 6517 T5 - 600A Frame magnetic only (MCP - AC only) Breaker IC at 480VAC T5N 25kA T5S 35kA T5H 65kA T5L 100kA Trip unit type Instantaneous only Instantaneous only Instantaneous only Instantaneous only Rating Adjustment range 3 pole, 600VAC Catalog number List price 600A 600-6000 T5N600E5W $ 5615 600A 600-6000 T5S600E5W 5770 600A 600-6000 T5H600E5W 7761 600A 600-6000 T5L600E5W 9370 15 1 600A Not available with thermal magnetic trip unit. Discount schedule S5T Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 Accessories Electrical T1 - T3 T M ma CC x Bs Shunt trips Factory installation KT3S4 Voltage Catalog number suffix 1 480 - 500VAC 220/250VAC/DC 380 - 440VAC 110 - 125VAC/DC 48 - 60VAC/DC 24 - 30VAC/DC 12VDC S1 S2 S3 S4 S7 S8 S9 Field installation List price adder Catalog number T1 - T3 List price $ 535 KT3S1 KT3S2 KT3S3 KT3S4 KT3S7 KT3S8 KT3S9 $ 490 For remote opening of circuit breaker and includes internal cut-off switch to protect solenoid. All shunt trips are left pole mounted and can not be used with undervoltage releases. All shunt trips are approved for use in ground fault systems. Electrical specifications Voltage AC VA DC Watts 24, 120, 240 48 - 60 480 - 500 50 60 55 50 60 -- Undervoltage releases Factory installation T1 with KT3S4 Voltage Catalog number suffix 1 480 - 500VAC 220 - 250VAC/DC 380 - 440VAC 110 - 125VAC/DC 60VAC/DC 48VAC/DC 24 - 30VAC/DC U1 U2 U3 U4 U5 U7 U8 List price adder $ 535 Field installation Catalog number T1 - T3 List Price KT3U1 KT3U2 KT3U3 KT3U4 KT3U5 KT3U7 KT3U8 $ 490 Will trip circuit breaker when connected voltage drops to 35 - 70% of undervoltage release voltage rating. Will allow circuit breaker to close (ON) when voltage is approximately 85% of rated voltage. All undervoltage releases are left pole mounted and can not be used with shunt trips. Electrical specifications KT3U2 Voltage AC VA DC Watts 24 48 - 60 120 220 - 250 480 - 500 1.5 1 2 2.5 4 1.5 1 2 2.5 -- 15 Auxiliary contacts -- T1 - T3 Factory installation Contacts Catalog number suffix 1 Form C + 1 BA 3 Form C + 1 BA T2 PR221DS 1 Form C + 1 BA 3 form C + 1 BA 24VDC A A3 A A3AU List price adder $ 433 770 433 770 Field installation Catalog number KT3AS KT3AS3 KT2AS-E KT3AS3-AU List Price $ 380 725 380 725 Electrical operators Field installation T1 with K3TAS Voltage Catalog number 48 - 60VAC/DC 110 - 250VAC/DC KT3M1 KT3M2 Electrical specifications Voltage range 85 - 110% rated voltage Inrush power 2500VA / 1000W KT3M1 1 For factory installation add suffix given to end of circuit breaker catalog number per accessory format. Discount schedule SAT Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com List Price $ 850 Contact us at: 15 ax s Tm CB C M +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com Accessories Mechanical T1 - T3 Direct mount rotary operator handle Catalog number List price KT3RH $ 146 Handle catalog number List price Direct mount rotary Variable depth rotary handles Frame Mechanism catalog number List price Shaft catalog number List price NEMA 1, 3R, 12 Tmax KT3VD-M $ 72 OXP6X430 1 $ 28 OHY65J6 1 OHB65J6 1 $ 80 KT3VD-M 72 OXP6X430 1 28 OHY80L6 1 OHB80L6 1 130 KT3VD-M 72 KT3VD-S 35 KT3VD-H NEMA 4, 4X KT3RH Tmax NEMA 1 Tmax 87 Locking device Catalog number Locking device, open/closed List price KT3LD Locking device, open $ 35 KT3LDO 35 OHB65J6 Lugs Amps Wire size T1 100 14AWG-1/0 Integral T2 100 14AWG-1/0 KT2100-3 $9 KT2100-4 $ 12 T3 60 100 150 225 14AWG -2AWG 14AWG -1/0 2AWG-4/0 4AWG-300kcmil KT3060-3 KT3100-3 KT3150-3 KT3225-3 9 9 12 18 KT3060-4 KT3100-4 KT3150-4 KT3225-4 12 12 18 24 For breakers Set of 3 catalog number List price Set of 4 catalog List price number Standard cable lugs OHY65J6 -- Integral -- Standard cable lug kits with power controls taps Set of 3 15 Set of 4 For breakers Amps Wire size Catalog number List price Catalog number List price T3 100 150 225 14AWG - 1/0 2AWG - 4/0 4AWG - 350kcmil KT3100-3C KT3150-3C KT3225-3C $ 16 16 25 KT3100-4C KT3150-4C KT3225-4C $ 19 19 31 KT3LD Extended front terminals Set of 3 For breakers Amps Catalog number T2 T3 100 225 KT2EF-3 KT3EF-3 For breakers Amps Catalog number T2 T3 100 225 Distribution cable lug kit Amps T3 225 Set of 4 List price adder Catalog number List Price $ 26 33 KT2EF-4 KT3EF-4 $ 35 44 List price adder Catalog number Rear terminals Set of 3 KT3100-3 Set of 4 KT2R-3 KT3R-3 $ 78 98 KT2R-4 KT3R-4 List Price $ 105 131 Set of 3 (6) #14-6 Catalog number KT3TN List Price $ 125 OHB 65 J 6 KT2EF-3 Color Shaft size (diameter in mm) B = Black Y = Red/Yellow Physical size (length in mm) KT2R-3 Wire range 1 Use Discount Schedule H6. J = Type 1, 3R, 12 L = Type 1, 3R, 12, 4, 4X Discount schedule SAT Discount schedule H6 -- Handles Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 Accessories Mechanical T1 - T3 T M ma CC x Bs DIN Rail mounting kits -- 35mm DIN 1 For breakers Catalog number List price T1 / T2 T3 KT2DIN KT3DIN $ 33 41 Terminal covers for fixed breakers Low Profile Low profile 3-pole Low profile 4-pole For breakers Catalog number List price Catalog number T1 T2 T3 KT1LTC-3 KT2LTC-3 KT3LTC-3 $ 35 40 50 KT1LTC-4 KT2LTC-4 KT3LTC-4 For breakers Catalog number List price Catalog number T1 T2 T3 KT1HTC-3 KT2HTC-3 KT3HTC-3 $ 37 43 53 KT1HTC-4 KT2HTC-4 KT3HTC-4 List price Catalog number KT2DIN High Profile High profile 3-pole List Price $ 47 54 68 High profile 4-pole List Price $ 50 58 72 Kit consists of two pieces. Plug-in kits for T2 and T3 2 KT1LTC-3 Moving part For breakers Catalog number T2 -- 3-Pole T3 -- 3-Pole KT2PMK KT3PMK Fixed part $ 171 190 KT2PFF KT3PFF List Price $ 238 264 Fixed parts accept the same cable and rear terminal kits as the circuit breakers. Sliding bar interlock -- front mounted For 2 breakers For breakers Catalog number T1 - T3 KT3MIF2 For 3 breakers List price $ 625 Catalog number KT3MIF3 List Price $ 844 KT1HTC-3 Plug connectors 15 Item 3 Way 6 Way 12 Way Shunt trip or UVR 1 form C + 1BA auxiliary contact 3 form C + 1BA auxiliary contact Catalog number List price KT3PC-3 $ 18 KT3PC-6 21 KT3PC-12 24 Cable kits Item KT2PFF + KT2PMK (on back of breaker) + breaker KT3MIF2 Catalog number List price 2 Cables, 2M KT3PC-2CK $ 18 6 Cables, 2M KT3PC-6CK 24 12 Cables, 2M KT3PC-12CK 30 1 For use with 15mm high DIN rail. 2 Plug connectors and cable kit required when mounting accessories. Discount schedule SAT Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: 15 ax s Tm CB C M +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com External accessories Flange handle operators T1 - T3 Flange handle -- Cable linkage Breaker NEMA Type Mechanism only T1/T2 T1/T2 T3 T3 1,3R,12 4,4X 1,3R,12 4,4X KT2FPM KT2FPM KT3FPM KT3FPM List price Cable only Cable length List price Handle only List price $ 123 K5C036 K5C048 K5C060 K5C072 36" (91cm) 48" (122cm) 60" (152cm) 72" (183cm) $ 114 146 160 175 K5FCH K5FCH4 K5FCH K5FCH4 $ 213 243 213 243 Notes: For complete assembly; mechanism, cable and handle are required. All cables mount onto the right side of the breaker. Handle can be mounted on the right or left side. Door hardware kits -- T1 - T5 Cable operated Catalog number Item Door hardware kit, right hand, 2 point latch for enclosures less than 40 inches high Door hardware kit, right hand, 3 point latch for enclosures 40 inches high or greater KDH2R KDH3R List price $ 200 225 Enclosure depths Minimum Breaker Depth (inches) T1 - T3 8 Maximum Maximum depth is determined by cable length. 15 Discount schedule SH Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 Accessories Electrical T4 - T5 T M ma CC x Bs Shunt trips (Standard) Factory installation Voltage Catalog number suffix 1 480 - 500VAC 220/250VAC/DC 380 - 440VAC 110 - 125VAC/DC 48 - 60VAC/DC 24 VAC/DC 12VDC S1 S2 S3 S4 S7 S8 S9 Field installation List price adder Catalog number T4 - T5 List price $ 535 KT5S1 KT5S2 KT5S3 KT5S4 KT5S7 KT5S8 KT5S9 $ 490 Shunt trip (Permanent supply) Factory installation Field installation Voltage Catalog number suffix 1 List price adder Catalog number T4 - T5 List price 110 - 120 VAC 24 - 30 VAC/DC SP4 SP8 $ 535 KT5SP4 KT5SP8 $ 490 Undervoltage release Factory installation Voltage Catalog number suffix 1 480 - 500 VAC 220 - 250 VAC/DC 380 - 440 VAC 110 - 125 VAC/DC 60 VAC/DC 48 VAC/DC 24 VAC/DC U1 U2 U3 U4 U5 U7 U8 Field installation List price adder $ 535 Catalog number T4 - T5 List Price KT5U1 KT5U2 KT5U3 KT5U4 KT5U5 KT5U7 KT5U8 $ 490 Auxiliary contacts Factory installation Catalog number suffix Contacts 1 Form C + 1 BA, 250 VAC/VDC 3 Form C + 1 BA, 250 VAC/VDC 3 Form C + 1 BA, 24 VDC A A3 A3AU Field installation List price adder $ 433 770 770 Catalog number KT5AS KT5AS3 KT5AS3-AU List Price $ 380 725 725 Stored energy motor operator 15 Field installation Voltage Catalog number 220 - 250 VAC/DC 110 - 125 VAC/DC 48 - 60 VDC 24 VDC KT5M2 KT5M4 KT5M7 KT5M8 List Price $ 2385 Stored energy motor operator - Contact remote/manual operation Factory installation Contacts Catalog number suffix 1 Form C MA Field installation List price adder $ 265 Catalog number KT5MA List Price $ 220 Adapters 2 Item KT5M2 6 Way 10 Way 12 Way Catalog number List price 1 Form C + 1BA KT5ADP-6 $ 24 Shunt trip / UVR KT5ADP-6 24 Stored energy motor operator KT5ADP-10 30 Stored energy motor operator plus shunt trip/UVR KT5ADP-10 30 KT5ADP-12 35 3 Form C + 1BA 1 For factory installation add suffix given to end of circuit breaker catalog number per accessory format. 2 Required when mounting accessories on plug-in/drawout breakers Discount schedule SAT5 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: 15 +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com Accessories Mechanical T4 - T5 ax s Tm CB C M Direct mount rotary operator handle Catalog number Item Direct mount rotary handle (for fixed and plug-in breakers) Direct mount rotary handle (for withdrawable breakers) KT5RH KT5RHW List Price $ 135 Variable depth rotary handles KT5RH Catalog number Item Mechanism NEMA 1, 12, 3R Handle (Black) NEMA 1, 12, 3R Handle (Grey) NEMA 4, 4X Handle (Black) NEMA 4, 4X Handle (Grey) Shaft (148mm / 5.8 in) Shaft (225mm / 8.9 in) Shaft (500mm / 19.7 in) KT5VD-M OHB95J10 1 OHG95J10 1 OHB95L10 1 OHG95L10 1 OXP10X148 1 OXP10X225 1 OXP10X500 1 NEMA 1 Handle, square profile Shaft (500mm/19.7in) KT5VD-H KT5VD-S List Price $ 65 80 80 120 120 24 26 32 87 Locking devices Catalog number List price Locking device KT5FLD $ 40 Locking device draw out KT5FLDW 55 Plug-in kits Breaker adapter kit Catalog number suffix Contacts KT4PFVR KT4PMK (on back of breaker) Plug-in base List price adder Catalog number List Price T4, 3 pole with extended front terminal T4, 3 pole with rear horizontal terminal T4, 3 pole with rear vertical terminal KT4PMK $ 250 KT4PFEF KT4PFHR KT4PFVR $ 710 766 766 T5, 3 pole with extended front terminal T5, 3 pole with rear horizontal terminal T5, 3 pole with rear vertical terminal KT5PMK 350 KT5PFEF KT5PFHR KT5PFVR 810 866 866 Draw-out kits Breaker adapter kit Contacts Catalog number suffix 15 KT5WFVR Plug-in base List price adder Catalog number List price T4, 3 pole with extended front terminal T4, 3 pole with rear horizontal terminal T4, 3 pole with rear vertical terminal KT4WMK $ 290 KT4WFEF KT4WFHR KT4WFVR $ 816 1021 1021 T5, 3 pole with extended front terminal T5, 3 pole with rear horizontal terminal T5, 3 pole with rear vertical terminal KT5WMK 407 KT5WFEF KT5WFHR KT5WFVR 931 1154 1154 Standard cable lugs KT4WMK (on back of breaker) For breakers Amps Wire size Set of 2 catalog number List price Set of 3 catalog number List price Set of 4 catalog number List price T4 100 250 14 AWG-1/0 6 AWG - 350 kcmil KT4100-2 KT4250-2 $6 20 KT4100-3 KT4250-3 $9 30 KT4100-4 KT4250-4 $ 12 40 T5 300 400 250kcmil - 500 kcmil (2) 3/0 - 250 kcmil KT5300-2 KT5400-2 30 30 KT5300-3 KT5400-3 45 45 KT5300-4 KT5400-4 60 60 T5 600 (2) 3/0 - 500 kcmil KT5600-2 TBD KT5600-3 TBD KT5600-4 TBD Standard cable lug kits with power control taps For breakers Amps Wire size Set of 2 catalog number List price Set of 3 catalog number List price Set of 4 catalog number List price T4 100 250 14 AWG-1/0 6 AWG - 350 kcmil KT4100-2C KT4250-2C $ 10 24 KT4100-3C KT4250-3C $ 15 36 KT4100-4C KT4250-4C $ 20 48 T5 300 400 250 kcmil - 500 kcmil KT5300-2C (2) 3/0 - 250 kcmil KT5400-2C 34 34 KT5300-3C KT5400-3C 51 51 KT5300-4C KT5400-4C 68 68 1 Use Discount schedule SH Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 Accessories Mechanical T4 - T5 T M ma CC x Bs Extended front terminals Set of three Set of four Amps Catalog number suffix List price adder 250 400 KT4EF-3 KT5EF-3 $ 55 115 Breaker Amps Catalog number suffix List price adder T4 T5 250 400 KT4R-3 KT5R-3 $ 60 122 Breaker T4 T5 Catalog number List Price KT4EF-4 KT5EF-4 $ 73 155 Rear terminals Set of three Set of four Catalog number KT4R-4 KT5R-4 List Price $ 80 163 KT4EF-_ Distribution cable lug kit Breaker Amps Wire range T4 T5 250 400 (6) #14-6 (6) #14-1/0 Set of 3 catalog number KT4TN KT5TGD List price $ 125 240 Terminal covers for fixed breakers Low profile Low profile 3-pole Catalog List number price For breakers T4 T5 KT4LTC-3 KT5LTC-3 $ 55 60 Low profile 4-pole Catalog List number price KT4LTC-4 KT5LTC-4 $ 74 81 High profile High profile 3-pole Catalog List number price For breakers KT4LTC-3 T4 T5 KT4HTC-3 KT5HTC-3 $ 58 63 High profile 4-pole Catalog List number price KT4HTC-4 KT5HTC-4 $ 78 85 Mechanical interlock plate -- complete assembly consists of one frame and one plate Catalog number Interlock frame Mechanical interlock horizontal frame Mechanical interlock vertical frame KT5MIR-HB KT5MIR-VB Catalog number Plate type A B C D E F T4 (F-P-W) T4 (F-P-W) T4 (F-P-W) T5 400 (F-P-W) or T5 630 (F) T5 400 (F-P-W) or T5 630 (F) T5 630 (P-W) + + + + + + T4 (F-P-W) T5 400 (F-P-W) or T5 630 (F) T5 630 (P-W) T5 400 (F-P-W) or 630 (F) T5 630 (P-W) T5 630 (P-W) KT5MIR-PA KT5MIR-PB KT5MIR-PC KT5MIR-PD KT5MIR-PE KT5MIR-PF KT4HTC-3 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com List price $ 490 588 List price $ 210 15 Contact us at: 15 ax s Tm CB C M +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com External accessories Flange handle operators T4 & T5 Flange handle -- Cable linkage Breaker NEMA Type Mechanism only T4 T4 T5 T5 - - - - 1, 3R, 12 4, 4X 1, 3R, 12 4, 4X - - - - KT4FPM KT4FPM KT5FPM KT5FPM - - - - List price $ 148 193 - - - - Cable only Cable length List price Handle only List price K5C036 K5C048 K5C060 K5C060 36" (91cm) 48" (122cm) 60" (152cm) 72" (183cm) $ 114 146 160 175 K5FCH K5FCH4 K5FCH K5FCH4 $ 213 243 213 243 K5C084 K5C096 K5C108 K5C120 84" (213cm) 96" (244cm) 108" (274cm) 120" (305cm) 204 221 238 256 - - - - - - - - Notes: For complete assembly; mechanism, cable and handle are required. All cables mount onto the right side of the breaker. Handle can be mounted on the right or left side. Door hardware kits - T4 & T5 Cable operated Catalog number Item Door hardware kit, right hand, 2 point latch for enclosures less than 40 inches high Door hardware kit, right hand, 3 point latch for enclosures 40 inches high or greater KDH2R KDH3R List price $ 200 225 Enclosure depths Minimum Breaker Depth (inches) T4 & T5 8 Maximum Maximum depth is determined by cable length. 15 Discount schedule SH Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 Enclosures Type 1 & 3R/12 T M ma CC x Bs T4E-3R12 3 T3E-1 Enclosures (Price does not include circuit breaker; order as a separate item.) 4 Approximate dimensions1 H x W x D (inches) NEMA designation Breaker type Enclosure maximum rating AL cables CU cables Catalog number Type 1 1 T1 T2 T3 T4 T5 100A 100A 175A 200A 325A 100A 100A 225A 250A 400A 15 x 8.5 x 4 15 x 8.5 x 4 20 x 11 x 4 26 x 15 x 6.25 26 x 15 x 6.25 T1E-1 T2E-1 T3E-1 T4E-1 2 T5E-1 2 Type 3R/123 T1 T2 T3 T4 T5 100A 100A 175A 200A 325A 100A 100A 225A 250A 400A 15 x 8.5 x 7 15 x 8.5 x 7 20 x 11 x 7 26 x 15 x 9 26 x 15 x 9 T1E-3R12 T2E-3R12 T3E-3R12 T4E-3R12 T5E-3R12 List price $ 267 267 315 407 435 407 407 527 625 767 Neutral kits Breaker type Neutral cable capacity and wire range Neutral kit catalog number List price T1 - T2 Neutral #14-1/0 Bonding Lug #14-1/0 T2NK125 $ 140 T3 Neutral #6-250 kcmil Bonding Lug #14-1/0 T3NK225 150 T4 Neutral #6-250 kcmil Bonding Lug #14-1/0 kcmil T4NK250 200 T5 Neutral (2) #6-250 kcmil Bonding Lug #14-1/0 kcmil T5NK400 295 NOTE: The list price adder for factory installation of an enclosed circuit breaker is 50% of the enclosure list price. Description Type 1 Type 3R/12 * General purpose indoor enclosure intended for use in normal environments to provide a degree of protection against contact with enclosed equipment. * Sheet steel, surface mount. * Breaker is front-operable and can be padlocked via a separately ordered padlock device. * Available through 400A, 600VAC * (SUSE) suitable for use as service equipment. 1 2 3 4 15 * Type 3R is intended for outdoor use providing protection against rain, sleet or snow. * Type 12 is for use in indoor atmospheres to provide a degree of protection against circulating dust, lint, sawdust, falling dirt and dripping non-corrosive liquids. * Surface-mounted, sheet steel enclosure. * Breaker can be operated via separately ordered handle mechanism; door is interlocked with mechanism. * Available through 400A, 600VAC. * (SUSE) suitable for use as service equipment. Padlocking provision must be ordered separately. Must order KT5FLD (padlock device) separately. Variable depth rotary handle must be ordered separately. Consult ABB for breakers installed in enclosures. Low Voltage Products & Systems Discount schedule SET Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15.33 Contact us at: 15 +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com Enclosures Approximate dimensions, T1 - T5 NEMA 1, 3R & 12 ax s Tm CB C M NEMA 1 ** *( ** 3(/7. 7)4( "2%!+%2 0!$,/#+ $%6)#% !.$ .%542!, +)4 /2$%2%$ 3%0!2!4%,9 & -4' (/,%3 0,!#%3 Cat. # " # ' % &2/.4 6)%7 3)$% 6)%7 3%#4)/. B C D E T1E-1 15.00 381 A 8.50 216 4.00 102 13.00 330 6.50 165 0.281 4.93 1, 1-1/4 3/4, 1 7 125 25, 32 19, 25 F G H J T2E-1 15.00 381 8.50 216 4.00 102 13.00 330 6.50 165 0.281 4.93 1, 1-1/4 3/4, 1 7 125 25, 32 19, 25 11.00 T3E-1 20.00 508 279 4.00 102 18.00 457 9.00 229 0.281 4.93 1, 1-1/4 3/4, 1 7 125 25, 32 19, 25 15.00 T4E-1 26.00 660 381 6.25 159 24.00 13.00 0.281 7.01 1, 1-1/4 3/4, 1 610 330 7 178 25, 32 19, 25 15.00 T5E-1 26.00 660 381 6.25 159 24.00 13.00 0.281 7.01 1, 1-1/4 3/4, 1 610 330 7 178 25, 32 19, 25 NEMA 3R, 12 3(/7. 7)4( "2%!+%2 6!2) $%04( -%#(!.)3- (!.$,% 3(!&4 !.$ .%542!, +)4 /2$%2%$ 3%0!2!4%,9 15 & -4' (/,%3 0,!#%3 B C D E F G T1E-3R12 15.00 381 Cat. # A 8.50 216 7.00 178 15.75 400 5.00 127 0.313 8 9.06 230 T2E-3R12 15.00 381 8.50 216 7.00 178 15.75 400 5.00 127 0.313 8 9.06 230 11.00 T3E-3R12 20.00 508 279 7.00 178 20.75 527 7.50 191 0.313 8 9.06 230 15.00 T4E-3R12 26.00 660 381 9.00 229 26.75 11.50 0.313 11.06 679 292 8 281 15.00 T5E-3R12 26.00 660 381 9.00 229 26.75 11.50 0.313 11.06 679 292 8 281 # " &2/.4 6)%7 15.34 ' 3)$% 6)%7 % 3%#4)/. Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 Trip curves for distribution Circuit breakers w/thermagnetic trip units Tmax T1 T1 100-T1 100 1P TMF t [s] T M ma CC x Bs 104 In = 15 / 70 A 103 102 10 1 10-1 40A 60A 30A 70A 50A 20A 25A 15A 10-2 10-1 T1 100-T1 100 1P TMF t [s] 1 10 102 x I1 104 In = 80 / 100 A 15 103 102 10 1 10-1 90A 100A 80A 10-2 10-1 1 10 102 x I1 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15.35 Contact us at: +91-9971138071; contactus@kmindustrialcorp.com 15 Trip curves for distribution Circuit breakers w/thermagnetic trip units Tmax T2 T2 100 TMF t [s] ax s Tm CB C M http://kmindustrialcorp.com 104 In = 15 / 50 A 103 102 10 1 10-1 40A 50A 30A 35A 25A 20A 15A 10-2 T2 100 TMF t [s] 10-1 1 10 102 x I1 10-1 1 10 102 x I1 104 In = 60 / 100 A 15 103 102 10 1 10-1 10-2 15.36 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com Trip curves for distribution Circuit breakers w/thermagnetic trip units Tmax T3 T3 225 TMF t [s] 15 T M ma CC x Bs 104 In = 60 / 100 A 103 102 10 1 60w100A 10-1 10-2 10-1 T3 225 TMF t [s] 1 10 102 x I1 104 In = 125 / 225 A 15 103 102 10 1 125w225A 10-1 10-2 10-1 1 10 102 x I1 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15.37 Contact us at: +91-9971138071; contactus@kmindustrialcorp.com 15 Trip curves for distribution Circuit breakers w/thermagnetic trip units Tmax T4 T4 250 TMF/TMD t [s] ax s Tm CB C M In = 20 / 50 A In = 15, 20 TMF In = 30, 40, 50 TMD http://kmindustrialcorp.com 104 103 102 10 1 10-1 In=15A I3=500A In=20A I3=500A In=30A I3=500A In=40A I3=500A In=50A I3=500A 10-2 10-1 T4 250 TMA t [s] 10 1 102 103 x I1 104 In = 80 / 250 A 15 103 102 10 1 10-1 I3=5...10 x In 10-2 10-1 15.38 1 10 102 x I1 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com Trip curves for distribution Circuit breakers w/thermagnetic trip units Tmax T5 T5 400 TMA t [s] 15 T M ma CC x Bs 104 In = 300 / 400 A 103 102 10 1 10-1 I3=5...10 x In 10-2 10-1 1 10 102 x I1 15 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15.39 Contact us at: +91-9971138071; contactus@kmindustrialcorp.com 15 Trip curves for distribution Circuit breakers w/electronic trip units Tmax T2 T2 100 PR221DS-LS t [s] ax s Tm CB C M 104 0.4-0.44-0.48-0.52-0.56-0.60-0.64-0.680.72-0.76-0.80-0.84-0.88-0.92-0.96-1 L 1 0.4 L-I Functions http://kmindustrialcorp.com 103 1.5 B 2 B 2.5 1 102 3 A A 3.5 4.5 6.5 7 7.5 8 8.5 9 10 5.5 10 102 1 I 10-1 10-2 10-3 10-1 1 10-1 10 1 x In T2 100 PR221DS-LS t [s] 104 0.4-0.44-0.48-0.52-0.56-0.60-0.64-0.680.72-0.76-0.80-0.84-0.88-0.92-0.96-1 L 0.4 15 L-I Functions 10 Iu [kA] 1 103 1 1.5 B B 102 2 2.5 A A 3 3.5 4.5 6.5 7 7.5 8 8.5 9 10 5.5 S C 10 102 B 1 10-1 10-2 10-3 10-1 15.40 1 10-1 10 x In 1 10 Iu [kA] Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 Trip curves for distribution Circuit breakers w/electronic trip units Tmax T2, T4 & T5 T2 100 PR221DS-I t [s] 104 T M ma CC x Bs 6.5 7 7.5 8 8.5 9 10 1 1.5 2 2.5 3 3.5 4.5 5.5 I Function I 103 102 10 102 1 10-1 10-2 10-3 10-1 10-1 10 1 1 x In T4 250 - T5 600 PR221DS t [s] 104 0.4-0.44-0.48-0.52-0.56-0.6-0.64-0.68-0.72-0.76-0.8-0.84-0.88-0.92-0.96-1 L L-I Functions 10 Iu [kA] 0.4 103 1 1.5 2 2.5 3 3.5 4.5 5.5 6.5 7 7.5 8 8.5 9 10 15 1 102 10 102 1 T4 10-1 T5 I 10-2 10-3 10-1 1 10 x In 1 10 Iu [kA] Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15.41 Contact us at: +91-9971138071; contactus@kmindustrialcorp.com 15 Trip curves for distribution Circuit breakers w/electronic trip units Tmax T4 & T5 T4 250 - T5 600 PR221DS t [s] ax s Tm CB C M 104 http://kmindustrialcorp.com 0.4-0.44-0.48-0.52-0.56-0.6-0.64-0.68-0.72-0.76-0.8-0.84-0.88-0.92-0.96-1 L L-S Functions 0.4 1 103 1.5 2 2.5 3 3.5 4.5 5.5 6.5 7 7.5 8 8.5 9 10 1 102 10 102 S 1 10-1 T4 T5 10-2 10-3 10-1 T4 250 - T5 600 PR222DS/P and PR222DS/PD 15 L-S-I Functions t [s] 10 1 104 x In 1 10 Iu [kA] 0.4-0.42-0.44-0.46-0.48-0.5-0.52-0.54-0.56-0.58-0.6-0.62-0.64-0.66-0.680.7-0.72-0.74-0.76-0.78-0.8-0.82-0.84-0.86-0.88-0.9-0.92-0.94-0.96-0.98-1 L 0.4 1.2 1.8 2.4 1 3 3.6 4.2 5.8 6.4 7 7.6 8.2 8.8 9.4 10 103 5.5 (l2t const = ON) 2.5 3 4 6.5 4.5 0.6 102 7 5 7.5 8 9 9.5 1.5 10 I 10.5 12 S I2t ON 1 102 10-1 T4 T5 10-2 10-3 10-1 15.42 1 10 x In 10 Iu [kA] Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 Trip curves for distribution Circuit breakers w/electronic trip units Tmax T4 & T5 T4 250 - T5 600 PR222DS/P and PR222DS/PD t [s] 104 T M ma CC x Bs 0.4-0.42-0.44-0.46-0.48-0.5-0.52-0.54-0.56-0.58-0.6-0.62-0.64-0.66-0.680.7-0.72-0.74-0.76-0.78-0.8-0.82-0.84-0.86-0.88-0.9-0.92-0.94-0.96-0.98-1 L 0.4 1.8 2.4 3 3.6 4.2 5.8 6.4 1 7 7.6 8.2 8.8 9.4 10 103 L-S-I Functions (I2t const = OFF) 2.5 3 5.5 6.5 4 4.5 5 7 102 7.5 8 1.2 0.6 9 9.5 1.5 I 10 10.5 12 S I2t OFF 1 102 T4 T5 10-1 10-2 10-3 10-1 1 10 x In T4 250 - T5 600 PR222DS/P and PR222DS/PD t [s] 104 0.2 0.25 G Function 10 Iu [kA] 103 0.45 0.55 0.75 1 15 0.8 102 G 10 1 I4=0.2...0.49 x In inhibition at 4 x In I4=0.5...0.79 x In inhibition at 6 x In I4=0.8...1.00 x In inhibition at 8 x In 10-1 10-2 10-3 10-1 1 10 102 x In Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15.43 Contact us at: +91-9971138071; contactus@kmindustrialcorp.com 15 Trip curves for MCP Circuit breakers w/magnetic only trip units Tmax T2 & T3 T2-T3 100 MCP t [s] ax s Tm CB C M Adjustable magnetic only trip unit I3 = 6...12 x In http://kmindustrialcorp.com 104 103 102 10 1 6 12 10-1 10-2 10-3 10-1 1 10 102 x In 15 15.44 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 Trip curves for MCP Circuit breakers w/PR221DS-I electronic trip unit Tmax T2, T4 & T5 T2 100 PR221DS-I t [s] T M ma CC x Bs 104 1 1.5 2 2.5 3 3.5 4.5 5.5 6.5 7 7.5 8 8.5 9 10 I Function 103 102 Overload limit 10 102 1 10-1 10-2 10-3 10-1 10 1 10-1 1 x In T4 250 - T5 600 PR221DS-I t [s] 10 Iu [kA] 104 1 1.7 2 2.5 3 3.5 4.5 5.2 6.5 7 7.5 8 8.5 9 10 I Function 103 15 102 Overload limit T4 320 - T5 630 Overload limit T4 250 - T5 400 10 102 1 10-1 I 10-2 10-3 10-1 1 10 10-1 x In 1 10 Iu [kA] Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15.45 Contact us at: +91-9971138071; contactus@kmindustrialcorp.com 15 Specific let-through energy curves Tmax T1 & T2, 240V T1 100 I2t [(kA)2s] ax s Tm CB C M http://kmindustrialcorp.com 1 240 V 90-100A 70-80A 40-50-60A 25-30A 20A 15A 10-1 10-2 1 T2 100 I2t [(kA)2s] 102 10 103 Irms [kA] 1 240 V 15 90-100A 70-80A 10-1 60A 40-50A 25-35A 20A 15A 10-2 10-3 10-1 15.46 1 10 102 103 Irms [kA] Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 Specific let-through energy curves Tmax T3 & T4, 240V T3 225 T M ma CC x Bs I2t [(kA)2s] 10 240 V 225A 200A 175A 125A 90-100A 70-80A 60A 1 10-1 1 T4 250 10 102 103 Irms [kA] I2t [(kA)2s] 10 240 V 15 1 100-250A 80A 40-50A 20-25A 10-1 10-2 1 10 102 103 Irms [kA] Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15.47 Contact us at: +91-9971138071; contactus@kmindustrialcorp.com 15 Specific let-through energy curves Tmax T5, 240V T5 600 I2t [(kA)2s] 10 ax s Tm CB C M http://kmindustrialcorp.com 240 V * Please ad ABB for 600 A availability 300-600A 1 10-1 1 10 102 103 Irms [kA] 15 15.48 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 Specific let-through energy curves Tmax T1 & T2, 480V T1 100 I2t [(kA)2s] T M ma CC x Bs 1 480 V 90-100A 70-80A 40-50-60A 25-30A 20A 15A 10-1 10-2 1 I2t [(kA)2s] T2 100 102 Irms [kA] 10 1 480 V 90-100A 15 70-80A 60A 40-50A 25-35A 20A 10-1 15A 10-2 10-3 10-1 1 10 102 103 Irms [kA] Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15.49 Contact us at: +91-9971138071; contactus@kmindustrialcorp.com 15 Specific let-through energy curves Tmax T3 & T4, 480V T3 225 I2t [(kA)2s] 10 ax s Tm CB C M http://kmindustrialcorp.com 480 V 225A 200A 175A 125A 90-100A 70-80A 60A 1 10-1 1 T4 250 15 102 10 103 Irms [kA] I2t [(kA)2s] 10 480 V 1 100-250A 80A 40-50A 20-25A 10-1 10-2 1 15.50 10 102 103 Irms [kA] Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 Specific let-through energy curves Tmax T5, 480V T5 600 T M ma CC x Bs I2t [(kA)2s] 10 480 V 300-600A 1 10-1 1 10 102 103 Irms [kA] 15 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15.51 Contact us at: +91-9971138071; contactus@kmindustrialcorp.com 15 Specific let-through energy curves Tmax T4 & T5, 600V T4 250 I2t [(kA)2s] 10 ax s Tm CB C M http://kmindustrialcorp.com 600 V 100-250A 1 80A 40-50A 20-25A 10-1 10-2 1 T5 600 I2t [(kA)2s] 10 103 Irms [kA] 102 10 600 V 15 300-600A 1 10-1 1 15.52 10 102 103 Irms [kA] Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 Approximate dimensions T1 & T2 T M ma CC x Bs T1 -- 3 pole T1 -- Single pole 15 83 78 90 30 70 30 9.38 Y 17 X X 45 130 181 65 53.25 76.2 106.5 T2 -- 2 & 3 pole Y >3 103 <2 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15.53 Contact us at: 15 ax s Tm CB C M +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com Approximate dimensions T3 T3 -- 2 & 3 pole Door cut-out for Tmax without faceplate 15 15.54 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com 15 Approximate dimensions T4 T M ma CC x Bs &IXED CIRCUIT BREAKER #APTION /VERALL DIMENSIONS WITH CABLED ACCESSORIES MOUNTED 3/2 # 562 # 2# /VERALL DIMENSIONS WITH CABLED AUXILIARY CONTACTS MOUNTED ONLY 1 39 &LANGE FOR COMPARTMENT DOOR $RILLING TEMPLATES OF THE COMPARTMENT DOOR 15 0/,%3 0/,%3 7ITH FLANGE 7ITHOUT FLANGE $RILLING TEMPLATES FOR SUPPORT SHEET &OR FRONT TERMINALS 0/,%3 &OR REAR TERMINALS 0/,%3 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15.55 Contact us at: 15 ax s Tm CB C M +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com Approximate dimensions T5 &IXED CIRCUIT BREAKER &IXING ON SHEET #APTION /VERALL DIMENSIONS WITH CABLED ACCESSORIES MOUNTED 3/2 # 562 # 2# /VERALL DIMENSIONS WITH CABLED AUXILIARY CONTACTS MOUNTED ONLY 1 39 &LANGE FOR COMPARTMENT DOOR $RILLING TEMPLATES OF THE COMPARTMENT DOOR 15 7ITH FLANGE 0/,%3 7ITHOUT FLANGE 0/,%3 $RILLING TEMPLATES FOR SUPPORT SHEET &OR FRONT TERMINALS 0/,%3 &OR REAR TERMINALS 0/,%3 0/,%3 15.56 0/,%3 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com Approximate dimensions T1 - T3 variable depth mechanism with OHB handle 15 T M ma CC x Bs 15 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15.57 Contact us at: 15 ax s Tm CB C M +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com Approximate dimensions T4 - T5 variable depth mechanism with OHB handle 15 15.58 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com Approximate dimensions T1 Flange handle, cable operated http://kmindustrialcorp.com 15 T M ma CC x Bs 15 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15.59 Contact us at: 15 ax s Tm CB C M +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com Approximate dimensions T2 Flange handle, cable operated 15 15.60 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com Approximate dimensions T3 Flange handle, cable operated http://kmindustrialcorp.com 15 T M ma CC x Bs 15 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15.61 Contact us at: 15 ax s Tm CB C M +91-9971138071; contactus@kmindustrialcorp.com http://kmindustrialcorp.com Approximate dimensions T4 Flange handle, cable operated 15 15.62 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Contact us at: +91-9971138071; contactus@kmindustrialcorp.com Approximate dimensions T5 Flange handle, cable operated http://kmindustrialcorp.com 15 T M ma CC x Bs 15 Low Voltage Products & Systems Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15.63