Surge Protection Module LED Lighting Surge Protection Module > LSP05G Europe Version LSP05G European Version Module Series RoHS Description Agency Approvals Agency Standard Agency File Number UL1449 E320116 Applications * Outdoor and Commercial LED Lighting * Roadway lighting * Traffic lighting * Digital signage * Wall wash lighting * * * * Parking garage lighting Flood lighting Tunnel lighting Street lighting Additional Information Datasheet Resources Samples Littelfuse's LSP05G European version thermally protected Surge Protective Device is a self-protected device specially designed to be used in outdoor and commercial LED lighting fixtures for transient overvoltage protection. It has been developed with Littelfuse's thermally protected varistor technology. Its built-in thermal disconnect function provides additional protection to prevent catastrophic failure and fire hazard even under extreme circumstances of varistor end-oflife or sustained over-voltage conditions. It also provides high line-to-earth/ground resistance, facilitating faster production line testing. LSP05G series connected option allows clear indication of thermal fault protection by disconnecting power to the luminaire, thereby signaling SPD module replacement. The LSP05G Surge Protective Device facilitates product compliance to IEEE C62.41.2 Location Category C Low. Features * Maximum Discharge Current 10kA, 8/20s * Meets ANSI C136.2 Enhanced Level 10kV/5kA and IEEE C62.41.2 Location Category C Low Exposure * Thermally Protected Varistor technology * Parallel and Series Connected SPD Options * IP66 Water-proof and Dust-proof * UL1449 Recognized * IEC 61643-11 Class II and EN 61643-11 Type 2 compliant. * IEC CB Scheme Certificate NL-37684 available for 240V and NL-40516 for 277V * Compact form factor with mounting tabs * 240Vac and 277Vac are available for Class I and Class II installation based on IEC luminaire protection classes and are marked CE * Series connected - Varistor thermal protection indication by removal of power to luminaire * High line-to-earth/ ground resistance * RoHS compliant Absolute Maximum Ratings * For ratings of individual members of a series, see Device Ratings and Specifications chart LSP05G Series Units Continous: Max AC Voltage Range (VM(AC)RMS) Continuous Current 275 to 320 V 5 A Transient: Maximum Discharge Current, 8/20s Waveform (Imax) 10,000 A Nominal Discharge Current, 8/20s Waveform (In) 5,000 A Operating Ambient Temperature Range (TA) -45 to +85 C Storage Temperature Range (TSTG) -45 to +90 C Isolation Voltage Capability (When the thermal disconnect opens) Insulation Resistance 600 V >1,000 M CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. (c) 2016 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 05/24/16 Surge Protection Module LED Lighting Surge Protection Module > LSP05G Europe Version LSP05G European Version Series Device Ratings & Specifications Part Number Parallel/ Series Operating Voltage (VAC) MCOV/UC1 (VAC) Maximum Discharge Current2 Imax (A) Nominal Discharge Current3 In (A) MLV4 (V) UP5 (V) LSP05G240PX3333 P 240 275 10,000 5,000 L-N:970 L-G:1410 N-G:1410 L-G:1600 N-G:1600 Safety Compliance IEC/ EN61643-116 Luminaire Class UL1449 I X II X L-N:1100 LSP05G240PX3316 P 240 275 10,000 5,000 L-N:970 L-G:1410 N-G:1410 L-N:1100 L-G:1600 N-G:1600 LSP05G240SX3333 S 240 275 10,000 5,000 L-N:970 L-G:1410 N-G:1410 L-N:1100 L-G:1600 N-G:1600 X I X LSP05G240SX3316 S 240 275 10,000 5,000 L-N:970 L-G:1410 N-G:1410 L-N:1100 L-G:1600 N-G:1600 X II X LSP05G277PX3333 P 277 320 10,000 5,000 L-N:1130 L-G:1410 N-G:1410 L-N:1200 L-G:1600 N-G:1600 I X LSP05G277PX3316 P 277 320 10,000 5,000 L-N:1130 L-G:1410 N-G:1410 L-N:1200 L-G:1600 N-G:1600 II X LSP05G277SX3333 S 277 320 10,000 5,000 L-N:1130 L-G:1410 N-G:1410 L-N:1200 L-G:1600 N-G:1600 X I X LSP05G277SX3316 S 277 320 10,000 5,000 L-N:1130 L-G:1410 N-G:1410 L-N:1200 L-G:1600 N-G:1600 X II X Glossary: 1. MCOV/UC: Maximum Continuous Operating Voltage - maximum r.m.s. voltage that could be continuously applied to the SPD. 2. Maximum Discharge Current Imax (A): The maximum discharge current is a measure of the SPDs maximum capability; single impulse of discharge current uses the 8/20s current waveform. 3. Nominal Discharge Current In (A): The nominal discharge current is a measure of the SPDs endurance capability; 15 impulses of discharge current uses the 8/20s current waveform. 4. MLV: UL1449 Measured limiting voltage; the highest value of residual voltage measurements during the application of impulses of 8/20s nominal discharge current (In); an average voltage value of 15 impulses 5. Up: IEC 61643-11 Voltage protection level; the highest value of residual voltage measurements during the application of impulses of 8/20s nominal discharge current (In); a rounding voltage value of maximum measurement. 6. Series module used in parallel connection for indication circuit connection. 7. LSP05G240S & LSP05G277S are certified by DEKRA with below IEC 61643-11 specifications. Parameter Value Unit Temporary overvoltage TOV LSP05G240S Specification UT 337 V LV system fault 255 V x 1.32 at tT = 5 s, TN power grid Temporary overvoltage TOV UT 442 V LV system fault 255 V x 1.732 at tT = 120 min, TN power grid Power grids TN Backup fuse 16 End of life indication A max., gG fuse Optical, light ON: SPD is functional Light OFF: SPD has reached end-of-life yes Max earth leakage current at Uc Condition 50 A Parameter Value Unit Temporary overvoltage TOV UT 403 V LV system fault 305 V x 1.32 at tT = 5 s, TN power grid Temporary overvoltage TOV UT 529 V LV system fault 305 V x 1.732 at tT = 120 min, TN power grid LSP05G277S Specification Power grids TN Backup fuse 20 End of life indication yes A Max. rms, to GND Condition max., gG fuse Optical, light ON: SPD is functional Light OFF: SPD has reached end-of-life LSP05G Protection Levels Up Ic 8/20 S 5kA LSP05G240S Differential mode U2 970V Common mode U1/U2 1600V/1410V Ic 8/20 S 5kA LSP05G277S Differential mode U2 1130V Common mode U1/U2 1600V/1410V Notes: * It is normal practice to disconnect components that intentionally breakdown between Line and Protective Earth, otherwise the apparent leakage current measured by the Hi-Pot tester may incorrectly be judged a "failure." * Maximum Discharge Current Imax (A): The maximum discharge current is a measure of the SPDs maximum capability; single impulse of discharge current uses the 8/20s current waveform. All Devices pass maximum discharge current with possible, safe opening of thermal disconnect. (c) 2016 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 05/24/16 Surge Protection Module L L N N AC/DC > LSP05G Europe Version LED Lighting Surge Protection Module + Power - Supply G LED Module SPD Parallel Connection Dimensions 26.01.5 Series Version 46.61.5 O4 0.5 L L N N + AC/DC Power - Supply G 28.61.5 .8 ~X3333 LED Module 100.020.0 Brown Blue Input 37.01.5 Brown Output Green with Yellow stripe Blue 46.11.5 100.020.0 Parallel Connection SPD (for Class II Unearthed) ~X3316 10.02.0 10.02.0 O4 L L N N 26.01.5 0.5 Parallel Version + AC/DC .8 Power - Supply G LED Module 46.61.5 28.61.5 O4 .8 0 .5 Parallel Connection 100.020.0 Blue Green with Yellow stripe 10.02.0 O4 R 46.11.5 Brown LED normally on SPD ~X3333 37.01.5 Notes: 1. Brown: Line; Blue: Neutral; Green-Yellow Stripe: Earth/Ground. 2. Wire Gauge: AWG16 (1.31mm2), wire length: 100mm20mm, wire stripping length:102mm. 3. Caution: Line/neutral wires must be correctly connected to AC power grid. Wiring error on line/neutral polarity may cause module failure. With LED indicating SPD status - ON (green): SPD is online - OFF: SPD needs replacement .8 0.5 Application/Installation Schematic L L N N + AC/DC Power Supply G L L N N - LED Module SPD L L N N + AC/DC Power - Supply G Parallel Connection SPD (for Class II Unearthed) ~X3316 L L N N G Series Connection ~X3333 LED Module LED Module L N AC/DC Power Supply G + - LED Module SPD ~X3316 + AC/DC Power - Supply LED Module Parallel Connection With LED indicating SPD status - ON (green): SPD is online - OFF: SPD needs replacement - SPD N (for Class II Unearthed) + ~X3333 L Series Connection Power Supply G Parallel Connection AC/DC LED normally on SPD ~X3333 R Notes: 1. Series module used in parallel connection for indication circuit connection. 2. LED indicator and associated circuitry are not included in the module. 3. Brown wire is AC line voltage (hot); blue wire is AC neutral voltage. 4. Brown wire voltage is cut off when SPD needs replacement. 5. R is current limiting resistor; it resistance/wattage is determined by AC line voltage and desired current driving LED. Example: AC line voltage 240V, LED: 1.6mA, resistor:150Kohm/0.5W. L L AC/DC + (c) 2016 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 05/24/16 Surge Protection Module LED Lighting Surge Protection Module > LSP05G Europe Version Repetitive Surge Capability 100,000 SURGE CURRENT (A) 10,000 1,000 100 MODEL SIZE = 20mm TA = -55oC TO 85 oC 130 to 625V M(AC) RATING 1 2 15 104 105 106 10 2 10 3 Pulse Rating (8x20Sec) Strikes Surge 1 2 15 100 1,000 10,000A 7,000A 5,000A 1,500A 700A 10 1 10 100 1,000 IMPULSE DURATION (s) 10,000 Part Numbering System LSP 05G 240 P N H Xxxxx Littelfuse Surge Protection Module 5kA (Nominal Discharge Current) Operating Voltage P: Parallel connection S: Series connection Blank: Waterproof IP66 N: Non-waterproof Blank: No Hi-Pot withstand capability in common mode H: With 1500Vac Hi-Pot withstand capability in common mode (L-G and N-G) (c) 2016 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 05/24/16 Suffix Code: X3333: with GND wire connection, available for 240Vac and 277Vac rating with CE Marking for Class I earthed luminaire installation Wire Color: Line: Brown, Neutral: Blue, Ground/P: Green with yellow stripe X3316: without GND wire connection, available for 240Vac and 277Vac rating with CE Marking for Class II unearthed luminaire installation Wire Color: Line: Brown, Neutral: Blue