Characteristics 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control circuits Environment Conformity to standards EN/IEC 60947-5-1, CSA C22-2 n 14 Product certifications XAC B XAC M XAC B XAC M For storage For operation Vibration resistance Standard version: CSA 300 V type 4 Standard version: CSA 300 V type 4 Standard version: "TH" Standard version: "TC", ("TH" on request) - 40...+ 70 - 25...+ 70 15 gn (10...500 Hz) conforming to IEC 60068-2-6 Shock resistance 100 gn conforming to IEC 60068-2-27 Protective treatment Ambient air temperature Electric shock protection Degree of protection Mechanical durability (in millions of operating cycles) Enclosure C C XAC B XAC M Class II Class I conforming to IEC 61140 IP 65 conforming to IEC 60529; IK 08 conforming to IEC 50102 1 XAC B XAC M Double insulated glass-reinforced polyester (colour: yellow) Aluminium enclosure. Painted yellow Rubber sleeve with stepped entry diameter for cable O 7...13 mm, O 10...22 mm or O 22...35 mm Cable entry Contact block characteristics a AC-15: A300 or Ue = 240 V, le = 3 A c DC-13: Q300 or Ue = 250 V, le = 0.27 A conforming to EN/IEC 60947-5-1 Appendix A Rated operational characteristics Thermal current (lthe) Rated insulation voltage (Ui) XEN Cpppp, XEN D3ppp, XEN D4ppp, XES B2011, XAC S4, XES D1181, XES D1281 XEN Bpppp, XEN D1ppp, XEN D2ppp Rated impulse withstand voltage (U imp) A V 400, degree of pollution 3, conforming to EN/IEC 60947-1 kV Positive operation 6, conforming to EN/IEC 60947-1 Mushroom head pushbutton: N/C contact with positive opening operation conforming to EN/IEC 60947-5-1 Appendix K Slow break or snap action Contact operation Resistance across terminals Operating force 10 500, degree of pollution 3, conforming to EN/IEC 60947-1 With booted operator M y 25 N XAC S4ppp: 10 (N/O), 8 (N/C); XEN Cpppp: 6 (N/O), 4 (N/C); XEN Bpppp, XEN D1ppp, XEN D2ppp: Single-speed: 9; 2-speed: 20 (1st speed), 30 (2nd speed); XEN D3ppp, XEN D4ppp: 25; XES B2011: 7; XES D1181, XES D128: 15 (1st speed), 25 (2nd speed) 10 With spring return mushroom N head operator With latching mushroom head N operator 40 Terminal referencing By numbers conforming to EN 50013 Short-circuit protection 10 A cartridge fuse type gG (gl) mm2 Connection Operational power conforming to EN/IEC 60947-5-1 Appendix C Utilisation categories AC-15 and DC-13 For 1 million operating cycles Operating rate: 3600 operating cycles/hour Load factor: 0.5 o Inductive circuit References: page 30076/3 2 Dimensions: page 30076/23 Screw and captive cable clamp terminals. Clamping capacity: 1 x 2.5 or 2 x 1.5 with or without cable end Contact blocks XEN Cpppp, XEN D3ppp, XEN D4ppp, XAC S4ppp a.c. supply a 50/60 Hz d.c. supply c Voltage V 24 48 127 230 Voltage V 24 VA 140 385 525 455 W 60 o o 48 45 120 42 Contact blocks XEN Bpppp, XEN D1ppp, XEN D2ppp a.c. supply a 50/60 Hz d.c. supply c Voltage V 24 48 127 230 Voltage V 24 VA 140 210 640 680 W 48 o o 48 31 120 35 Contact blocks XES B2011, XES D1181, XES D1281 a.c. supply a 50/60 Hz d.c. supply c Voltage V 24 48 127 230 Voltage V 24 VA 50 100 450 750 W 140 o o 48 140 120 95 Application schemes: page 30076/24 version: 9.3 30076-EN.indd References 6 Pendant control stations 6 Double insulated, type XAC B For control circuits Complete stations "ready for use" (with snap action contact blocks) 1 C/O snap action XES B2011 6 without mechanical interlocking 1 C/O snap action XES B2011 8 without mechanical interlocking 1 C/O snap action XES B2011 1 3 4 3 4 without mechanical interlocking Reference Weight kg XAC B281 0.850 XAC B481 1.100 XAC B681 1.300 XAC B881 1.550 1 3 4 1 3 4 I XAC B681 2 DF565567 XAC B481 2 DF565566 XAC B281 4 DF565565 2 without mechanical interlocking Contact blocks and scheme Per direction 1 C/O snap action XES B2011 2 Number of operators 1 Functions 2 DF565564 For control of single-speed motors O XAC B881 30076-EN.indd version: 9.3 3 Characteristics 6 Pendant control stations 6 Double insulated, type XAC B For power circuits (direct switching) Environment Conformity to standards Product certifications Standard version EN/IEC 60947-5-1 EN/IEC 60204-32, UL 508, CSA C22-2 n 14 EN/IEC 60947-5-5 and EN/ISO 13850 for versions with trigger action Emergency stop EN/IEC 60947-3 CSA type 4 Protective treatment Standard version "TH" Ambient air temperature For storage For operation C C Vibration resistance - 40...+ 70 - 25...+ 70 15 gn (10...500 Hz) conforming to IEC 60068-2-6 Shock resistance 100 gn conforming to IEC 60068-2-27 Electric shock protection Class II conforming to IEC 61140 Degree of protection IP 65 conforming to IEC 60529 Mechanical durability (in millions of operating cycles) Enclosure 1 except for XAC B91p and XAC CB92p: 0.4 Double insulated glass-reinforced polyester (colour: yellow) Cable entry Rubber sleeve with stepped entry diameter for cable O 10...O 22 mm Contact block characteristics Thermal current (lthe) XES D1191, XES D1291 XES D2201, XES D2241, XES D2251 Rated insulation voltage (Ui) XES Dpppp XAC Sp99 XES D1ppp XES D2ppp Rated impulse withstand voltage (U imp) A A 12 20 V V V V kV 500, degree of pollution 3, conforming to IEC 60947-1 400, degree of pollution 3, conforming to IEC 60947-1 600, conforming to CSA 300, conforming to CSA 6, conforming to IEC 60947-1 Contact operation Operating force Snap action XES D1ppp XES D2ppp N N Terminal referencing Short-circuit protection XES D1ppp XES D2ppp mm2 Connection Operational power 3 phases, 2 poles XES D1ppp 3 phases, 3 poles XES D2ppp 3 phases, 3 poles, isolating block XAC Sp99 3 phases, 2 poles XES D1ppp 3 phases, 3 poles XES D2ppp 3 phases, 2 poles Mechanical durability (in millions of operating cycles) XES D1ppp Utilisation categories AC-3 and AC-4 conforming to EN/IEC 60947-3 Appendix A Duty cycle comprising 75% AC-3, 3 phases, 3 poles 25% AC-4 Operating rate: 600 operating cycles XES D2ppp per hour Load factor: 0.4 References: page 30076/5 4 Dimensions: page 30076/23 17 32 By numbers conforming to CENELEC EN 50005 10 A maximum cartridge fuse type aM 12 A maximum cartridge fuse type aM Captive screw clamp terminals Clamping capacity: 1 x 2.5 or 2 x 1.5 with or without cable end Utilisation categories AC-3 and AC-4 conforming to EN/IEC 60947-3 Appendix A 2.2 kW-240 V 2.2 kW-400 V 3 kW-240 V 3 kW-400 V Utilisation category AC-23B 3 kW-400 V CSA certification 2 hp-240 V 5 hp-400 V 3 hp-600 V 3 hp-240 V 1.5 kW-240 V = 0.5 2.2 kW-240 V = 0.3 1.5 kW-400 V = 0.8 2.2 kW-400 V = 0.3 3 kW-240 V = 0.7 3 kW-400 V = 1 Application schemes: page 30076/25 version: 9.3 30076-EN.indd References 6 Pendant control stations 6 Double insulated, type XAC B For power circuits (direct switching) Complete stations "ready for use" Functions Number of operators DF565569 DF565568 For control of single-speed motors 2 mechanically interlocked XAC B3195 XAC B3205 DF565571 XAC B219 XAC B220 DF565570 2 mechanically interlocked + 1 trigger action latching Emergency stop O 40 mm operator ZA2 BS844 4 mechanically interlocked between pairs XAC B4916 XAC B4936 DF565572 XAC B491 XAC B493 4 mechanically interlocked between pairs + 1 trigger action latching Emergency stop O 40 mm operator ZA2 BS844 4 mechanically interlocked between pairs + 1 trigger action latching Emergency stop O 40 mm operator ZA2 BS844 mounted in base Maximum operational power/400 V Reference For Emergency stop - 2.2 kW XAC B219 kg 0.355 3-pole XES D2201(1) - 3 kW XAC B220 0.355 2-pole XES D1191(1) 1 N/C + N/C + N/C XAC S499 2.2 kW XAC B3195 r 0.940 3-pole XES D2201(1) 1 N/C + N/C + N/C XAC S499 3 kW XAC B3205 r 1.000 2-pole XES D1191(1) - 2.2 kW XAC B491 1.200 3-pole XES D2201(1) - 3 kW XAC B493 1.330 2-pole XES D1191(1) 1 N/C + N/C + N/C XAC S499 2.2 kW XAC B4916 r 1.260 3-pole XES D2201(1) 1 N/C + N/C + N/C XAC S499 3 kW XAC B4936 r 1.390 2-pole XES D1191(1) 1 N/C + N/C + N/C XAC S3991 2.2 kW XAC B4915 r 1.350 3-pole XES D2201(1) 1 N/C + N/C + N/C XAC S3991 3 kW XAC B4935 r 1.480 Contact blocks Per direction 2-pole XES D1191(1) Weight (1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. XAC B4915 XAC B4935 r Available 3rd quarter of 2011 30076-EN.indd version: 9.3 5 References (continued) 6 Pendant control stations 6 Double insulated, type XAC B DF565573 For power circuits (direct switching) Complete stations "ready for use" For control of single-speed motors (continued) Functions Number of operators 6 mechanically interlocked between pairs 6 mechanically interlocked between pairs + 1 trigger action latching Emergency stop O 40 mm operator ZA2 BS844 XAC B691 XAC B693 DF565574 DF565575 6 mechanically interlocked between pairs + 1 trigger action latching Emergency stop O 40 mm operator ZA2 BS844 mounted in base Maximum operational power/400 V Reference For Emergency stop - 2.2 kW XAC B691 kg 1.350 3-pole XES D2201(1) - 3 kW XAC B693 1.550 2-pole XES D1191(1) 1 N/C + N/C + N/C XAC S499 2.2 kW XAC B6916 r 1.410 3-pole XES D2201(1) 1 N/C + N/C + N/C XAC S499 3 kW XAC B6936 r 1.610 2-pole XES D1191(1) 1 N/C + N/C + N/C XAC S3991 2.2 kW XAC B6915 r 1.500 3-pole XES D2201(1) 1 N/C + N/C + N/C XAC S3991 3 kW XAC B6935 r 1.700 Maximum operational power/400 V Reference 2.2 kW XAC B229 kg 0.405 2.2 kW XAC B3295 r 0.990 Contact blocks Per direction 2-pole XES D1191(1) Weight For control of 2-speed motors Functions Number of operators 2 mechanically interlocked DF565577 DF565576 2-pole XES D1291(1) 2 2-pole mechanically XES D1291(1) interlocked + 1 trigger action latching Emergency stop O 40 mm operator ZA2 BS844 XAC B6915 XAC B6935 XAC B6916 XAC B6936 Contact blocks Per direction For Emergency stop - 1 N/C + N/C + N/C XAC S499 Weight (1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. XAC B229 XAC B3295 r Available 3rd quarter of 2011 Characteristics: page 30076/4 6 Dimensions: page 30076/23 Application schemes: page 30076/25 version: 9.3 30076-EN.indd References 6 Pendant control stations 6 Double insulated, type XAC B For control or power circuits Empty enclosures DF565578 DF565579 Empty enclosures for control circuits or power circuits (1) Description Empty enclosures (1) Double insulated for "Small hoist" applications Operator cut-out centres: 40 mm XAC B020 Number of cut-outs 2 Cut-out in base of enclosure Without Reference XAC B020 Weight kg 0.760 3 Without XAC B030 0.760 2 Without XAC B02 0.760 With XAC B021 0.760 Without XAC B04 1.000 With XAC B041 1.000 Without XAC B06 1.160 With XAC B061 1.160 Without XAC B08 1.330 With XAC B081 1.330 Without XAC B12 1.460 With XAC B121 1.460 XAC B030 DF565581 DF565580 Protective cable sleeve For cable O 7...13 mm Empty enclosures (1) Double insulated for "General purpose" applications Operator cut-out centres: 40 mm For cable O 10...22 mm 4 XAC B04p DF565583 DF565582 XAC B02p 6 8 DF565584 XAC B06p 12 in 2 rows of 6 XAC B08p (1) Enclosure comprising: - the enclosure, - protective cable sleeve, - cable tie (for tightening sleeve onto cable), - internal cable clamp, - suspension ring, - bezel tightening key. XAC B12p 30076-EN.indd version: 9.3 7 References (continued) 6 Pendant control stations 6 Double insulated, type XAC B For control or power circuits Empty enclosures Empty enclosures for control circuits or power circuits (1) (continued) DF565580 DF565581 Description Empty enclosures (1) Double insulated for "General purpose" applications Operator cut-out centres: 40 mm Protective cable sleeve For cable O 22...35 mm Number of cut-outs 2 4 Reference With XAC B0215 0.960 Without XAC B045 1.200 With XAC B0415 1.200 Without XAC B065 1.360 With XAC B0615 1.360 Without XAC B085 1.530 With XAC B0815 1.530 Without XAC B125 1.660 With XAC B1215 1.660 XAC B025 Weight kg 0.960 XAC B04pp XAC B02pp DF565583 DF565582 Cut-out in base of enclosure Without 6 8 DF565584 XAC B06pp 12 in 2 rows of 6 XAC B08pp (1) Enclosure comprising: - the enclosure, - protective cable sleeve, - cable tie (for tightening sleeve onto cable), - internal cable clamp, - suspension ring, - bezel tightening key. XAC B12pp Characteristics: pages 30076/2 and 30076/4 8 Dimensions: page 30076/23 Application schemes: page 30076/24 Presentation: page 30076/26 version: 9.3 30076-EN.indd References 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control circuits Empty enclosures (XAC M: products for maintenance purposes only) DF565585 Empty enclosures for control circuits (1) Description Empty enclosures (1) Double insulated for "General purpose" applications Operator cut-out centres: 30 mm Protective cable sleeve For cable O 10...22 mm For cable O 22...35 mm Empty enclosures (1) Metal for "General purpose" applications Operator cut-out centres: 40 mm For cable O 10...22 mm Number of cut-outs 12 in 1 row 12 in 1 row 4 XAC B120 DF565586 DF565587 8 For cable O 22...35 mm 4 8 XAC M04p Cut-out in base of enclosure Without Reference With XAC B1201 1.330 Without XAC B1205 1.530 With XAC B12015 1.530 Without XAC M04 1.540 With XAC M041 1.540 Without XAC M08 2.210 With XAC M081 2.210 Without XAC M045 1.740 With XAC M0415 1.740 Without XAC M085 2.410 With XAC M0815 2.410 XAC B120 Weight kg 1.330 XAC M08p Variable composition stations, factory assembled Use the order form on page 30076-EN/27 to define the required configuration Equipment: contact blocks, operating heads (control and signalling), complementary accessories See separate components, pages 30076/10 to 30076/22 (1) Enclosure comprising: - the enclosure, - protective cable sleeve for cable O 10...22 mm or O 22...35 mm, - cable tie (for tightening sleeve onto cable), - internal cable clamp, - suspension ring, - bezel tightening key. 30076-EN.indd version: 9.3 9 References 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control circuits Separate components and spare parts Contact blocks for front mounting, slow break Description Application Function Scheme Operator centres mm Reference Weight 30 or 40 XEN C1111 0.020 30 or 40 XEN C1121 0.020 30 or 40 XEN C1131 0.020 30 or 40 XEN C1141 0.020 30 or 40 XEN C1151 0.020 30 or 40 XEN B1491 0.050 30 or 40 XEN B1181 0.050 30 or 40 XEN B1191 0.050 30 XEN D1611 0.110 40 (1) XEN D2611 0.110 30 XEN D1621 0.110 40 (1) XEN D2621 0.110 kg Single-speed N/O N/C 23 24 21 22 13 11 12 13 23 24 23 24 43 13 24 43 44 23 14 44 14 11 23 12 24 31 32 33 34 31 32 23 2 step N/O + N/O staggered 24 2-speed 43 XEN D2611 Single-speed N/O + N/O simultaneous 44 Double block 2 spring return operators mechanically interlocked 13 DF565590 2 step C/O + N/O staggered 14 2 step N/O + N/O staggered 33 2-speed 34 XEN B1181 13 C/O + N/O 14 N/C + N/O 33 DF565589 N/C + N/C 34 N/O + N/O 14 12 XEN C1111 11 14 Single block 1 spring return operator 13 DF565588 Spring return (1) These contact blocks cannot be mounted in enclosures XAC B120p (12 operators in 1 row). Characteristics: pages 30076/2 and 30076/4 10 Dimensions: page 30076/23 Application schemes: page 30076/24 Presentation: page 30076/26 version: 9.3 30076-EN.indd References (continued) 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control circuits Separate components and spare parts Contact blocks for front mounting, slow break (continued) Description Application Function Scheme Operator centres mm Reference Weight 30 XEN D1631 0.110 40 (1) XEN D2631 0.110 30 XEN D1641 0.110 40 (1) XEN D2641 0.110 30 XEN D3801 0.170 40 (1) XEN D4801 0.170 30 XEN D3811 0.170 40 (1) XEN D4811 0.170 Operator centres mm Reference 40 (1) XES B2011 0.030 40 (1) XES D1181 0.140 40 (1) XES D1281 0.190 kg 23 24 53 54 24 53 54 23 14 43 44 31 32 61 62 14 43 13 32 61 31 2 step C/O + N/O staggered DF565592 2-speed 44 XEN D2641 Single-speed C/O + N/O 62 DF565593 Double block 2 spring return operators mechanically interlocked 13 Spring return (continued) 24 23 24 23 24 23 24 11 12 11 12 11 12 11 Single-speed N/C + N/O DF565591 Double block 2 latching operators 12 XEN D3801 23 Latching Double block Single-speed N/C + N/O 1 latching operator released by 1 spring return operator Contact blocks for front mounting, snap action Description Application Function Scheme XES B2011 Weight kg 3 4 13 33 43 44 34 23 24 14 21 22 13 14 11 22 21 12 C/O + N/O staggered 23 2-speed XES D1181 1 Single-speed C/O 2 Double block 2 spring return operators mechanically interlocked 11 Single-speed C/O 12 Single block 1 spring return operator (2) 24 DF565594 Spring return (1) These contact blocks cannot be mounted in enclosures XAC B120p (12 operators in 1 row). (2) Only for mounting with operators XAC B91pp. 30076-EN.indd version: 9.3 11 References (continued) 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control circuits Separate components and spare parts Contact blocks for front mounting (1) Reference XAC S411 Weight kg 0.070 XAC S412 0.070 XAC S413 0.070 XAC S414 0.070 XAC S415 0.070 Reference XAC S4111 Weight kg 0.100 XAC S4121 0.100 XAC S4131 0.100 XAC S4141 0.100 XAC S4151 0.100 14 N/O N/C 23 24 21 22 13 11 12 11 N/C + N/O 23 N/C + N/C 12 N/O + N/O 14 12 XAC S41p 24 530240 Spring return Slow break Operator centres 30 or 40 mm Scheme 13 Function 11 Description Contact blocks for base mounting (1) Function N/O 13 23 24 N/O + N/O 14 12 N/C 11 14 Spring return Slow break Scheme 13 530240 Description 11 21 22 11 23 12 N/C + N/O 24 N/C + N/C 12 XAC S4111 Pilot light bodies for front mounting Description Supply voltage y 400 V DF565595 Direct supply Bulb not included (2) Scheme X1 Reference XAC V06 Weight kg 0.050 XAC V07 0.055 X2 XAC V06 Direct supply, through resistor Incandescent BA 9s base fitting 130 V bulb included 230 V X1 X2 (1) Mounting with operating heads ZA2 Bppp (see page 30076/15). (2) Bulb type for use with direct supply units: BA 9s base fitting incandescent bulb U y 130 V or neon bulb 110 V y U y 400 V. Maximum power: 2.6 W, maximum O: 11 mm, maximum length: 26 mm. See page 30076/18. Characteristics: pages 30076/2 and 30076/4 12 Dimensions: page 30076/23 Application schemes: page 30076/24 Presentation: page 30076/26 version: 9.3 30076-EN.indd References 6 Pendant control stations 6 Double insulated, type XAC B For power circuits (direct switching) Separate components and spare parts Contact blocks, snap action 23 XES D1191 Weight kg 0.140 XES D1291 0.190 XES D2201 0.200 XES D2241 0.210 XEN D2251 0.210 54 51 61 64 62 52 24 43 44 43 73 74 33 73 84 44 34 63 74 24 23 63 34 33 33 53 64 44 43 23 44 24 13 33 13 34 14 N/O + N/O 3 kW + N/O + 1 N/O simultaneous auxiliary contact (1) 64 14 13 34 14 3 kW 23 N/O + N/O + N/O 54 Double block Single3-pole speed 2 spring return operators mechanically interlocked (operator centres: 40 mm) 2.2 kW 13 530368 XES D1191 N/O + N/O + 1 C/O staggered auxiliary contact (1) 14 2-speed N/O + N/O Reference 53 DF565594 SingleDouble block speed 2-pole 2 spring return operators mechanically interlocked (operator centres: 40 mm) Max. power/ Scheme 400 V 2.2 kW 24 Application Function 54 Description 530369 43 84 44 44 23 33 34 73 74 24 63 64 14 53 54 N/O + N/O 3 kW + N/O + 1 N/O staggered auxiliary contact (1) 13 XES D2201 Isolating block, slow break In the interests of safety, it is imperative that these isolating blocks only be used with a stay put or latching type operating head to ensure complete isolation when the pendant station is not in use. 31 32 31 31 32 21 32 530366 22 3 kW 21 Emergency N/C + N/C stop + N/C with positive opening operation 22 In base (3) XAC S499 21 3 kW 22 Emergency N/C + N/C stop + N/C with positive opening operation 11 On front 30 mm centres (2) 12 Emergency N/C + N/C stop + N/C with positive opening operation Reference 11 On front 40 mm centres (2) Scheme 12 530391 XAC S399 Max. power/ 400 V 3 kW 11 Application Function 12 Mounting position Weight kg XAC S399 0.100 XAC S499 0.100 XAC S3991 0.110 (1) Auxiliary contacts are slow break. (2) Mounting with operating heads ZA2 Bppp, except ZA2 BDp and ZA2 BGp (see page 30076/15). (3) Mounting with operating head ZA2 BS944 (see page 30076/15). XAC S3991 30076-EN.indd version: 9.3 13 References 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits Separate components and spare parts DF565596 Booted operators XAC B911p For use with contact block XEN Bpppp XEN Cpppp XEN Dpppp XES B2011 XES D2201 XES D2241 XES D2251 Travel 4 mm Operating temperature - 25...+ 70 C (1) DF565597 - 40...+ 70 C (2) XES D1181 XES D1191 XES D1281 XES D1291 16 mm - 25...+ 70 C (1) XAC B921p - 40...+ 70 C (2) Colour of insert White Sold in lots of 10 Unit reference XAC B9111 Weight kg 0.005 Black 10 XAC B9112 0.005 Green 10 XAC B9113 0.005 Red 10 XAC B9114 0.005 Yellow 10 XAC B9115 0.005 Blue 10 XAC B9116 0.005 Brown 10 XAC B9119 0.005 White 10 XAC B9121 0.005 Black 10 XAC B9122 0.005 Green 10 XAC B9123 0.005 Red 10 XAC B9124 0.005 Yellow 10 XAC B9125 0.005 Blue 10 XAC B9126 0.005 Brown 10 XAC B9129 0.005 White 10 XAC B9211 0.005 Black 10 XAC B9212 0.005 Green 10 XAC B9213 0.005 Red 10 XAC B9214 0.005 Yellow 10 XAC B9215 0.005 Blue 10 XAC B9216 0.005 Brown 10 XAC B9219 0.005 White 10 XAC B9221 0.005 Black 10 XAC B9222 0.005 Green 10 XAC B9223 0.005 Red 10 XAC B9224 0.005 Yellow 10 XAC B9225 0.005 Blue 10 XAC B9226 0.005 Brown 10 XAC B9229 0.005 Booted operators (silicone boot) DF565598 For use with contact block XAC S41p Operating temperature - 25...+ 70 C ZA2 BPp Colour of boot Black Reference ZA2 BP2 Weight kg 0.015 Green ZA2 BP3 0.015 Red ZA2 BP4 0.015 Yellow ZA2 BP5 0.015 Blue ZA2 BP6 0.015 (1) Polychloroprene boots. (2) Silicone boots. Characteristics: pages 30076/2 and 30076/4 14 Dimensions: page 30076/23 Application schemes: page 30076/24 Presentation: page 30076/26 version: 9.3 30076-EN.indd References 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M DF538492 For control or power circuits Separate components and spare parts Operating heads for front or base mounting (1) Description DF538493 ZA2 BS844 530382 ZA2 BS944 530383 ZA2 BDp 530381 ZA2 BGp ZA2 BBp Colour Type Reference Red O 30 mm ZA2 BS834 Weight kg 0.028 O 40 mm ZA2 BS844 0.033 O 30 mm ZA2 BS934 0.060 O 40 mm ZA2 BS944 0.065 Black 2 position, stay put 3 position, stay put (5) ZA2 BD2 ZA2 BD3 0.018 0.018 - Key switches (key n 455) (3) Key withdrawal in left and right-hand positions - Key switches (key n 455) (3) Key withdrawal in left-hand position Key switches - (key n 455) (3) Spring return from right to left Key withdrawal in left-hand position - Key switches (key n 455) (4) (3) Key withdrawal in centre position Wobblesticks (6) Black Operates in all directions for Red fast stop 2 position, stay put 3 position, stay put (5) ZA2 BG4 ZA2 BG5 0.042 0.042 2 position, stay put ZA2 BG2 0.042 2 position ZA2 BG6 0.042 3 position, stay put (5) ZA2 BG3 0.042 - - ZA2 BB2 ZA2 BB4 0.060 0.060 Type Reference O 40 mm ZA2 BS14 Trigger action latching Emergency stop (2) Turn to release (Emergency stop function) Trigger action latching Emergency stop (2) (3) Key release (n 455) Key withdrawal in rest (unactuated) position (Emergency stop function) Selector switches, standard handle (4) Red Operating head for isolating block Description Colour Mushroom head, latching Red Key release (n 455) Key withdrawal in rest (unactuated) position (Emergency stop function) Weight kg 0.065 Pilot light heads Description Colour Reference Weight kg For use with incandescent bulbs 530390 Lens cap with fixing bezel White ZA2 BV01 0.015 Green ZA2 BV03 0.015 Red ZA2 BV04 0.015 Yellow ZA2 BV05 0.015 Blue ZA2 BV06 0.015 Clear ZA2 BV07 0.015 Green ZA2 BV033 0.015 Red ZA2 BV043 0.015 Yellow ZA2 BV053 0.015 Clear ZA2 BV073 0.015 For use with neon bulbs Lens cap with fixing bezel ZA2 BV0p (1) The technical characteristics of pendant control stations XAC B and XAC M can only be guaranteed by using the operating heads ZA2 Bpp listed above. (2) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. (3) Other key numbers available on request, please consult your Customer Care Centre. (4) Selector switches or key switches with other mechanical functions: please consult your Customer Care Centre. (5) Only suitable for front mounting. (6) Base mounting recommended. 30076-EN.indd version: 9.3 15 Characteristics 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control circuits Separate components: pushbuttons with analogue output (1) Environment Conformity to standards EN/IEC 60947-5-1 Ambient air temperature For storage For operation C C - 40...+ 70 - 25...+ 70 IP 65 conforming to IEC 60529 Pushbutton operator travel mm 11 Operating force N Mechanical durability (in millions of operating cycles) Connection 4 (start of travel) 9 (end of travel) 1 mm2 Terminal connectors, maximum clamping capacity: 2 x 1.5 mm2 or 1 x 2.5 mm2 Thermal current (lthe) A 6 Rated insulation voltage (Ui) V 250, degree of pollution 3, conforming to IEC 60947-1 Degree of protection Contact block characteristics a.c. supply a 50/60 Hz Power broken in VA for 1 million operating cycles Voltage V 48 110 30 30 VA o Rated operational characteristics conforming to 947-5-1 Appendix C Utilisation categories AC-15 and DC-13 o Inductive circuit d.c. supply c Power broken in W for 1 million operating cycles Voltage V 48 110 48 12 o W 230 30 Analogue circuit characteristics Type of current d.c. Rated supply voltage V 15 Voltage limits V 14...18 Current consumption mA < 15 Analogue signal output curves and schemes Analogue signal output curves Equivalent output schemes XEA p15361 with 15 V supply voltage XEA p25361 11 11 Travel on pushbutton operator (mm) 10 12 23 5 24 33 34 XEA 15631 - 10 V 11 - 15 V 0V 12 0 23 1 k 0 S 10 k 10 V 0V 10 k 10 V 1 k S 24 33 34 + 15 V XEA 25361 0 + 10 V Note: supply voltage = 15 V, output voltage = 10 V (if supply voltage < 15 V, output voltage < 10 V) Contact state 0,5 mm contact closed 23 - 24 11 - 12 33 - 34 0 0,4 mm 11,5 mm contact open (1) Pushbuttons providing an analogue output signal proportional to the distance travelled by the pushbutton operator. References: page 30076/17 16 Dimensions: page 30076/17 version: 9.3 30076-EN.indd Pendant control stations References, dimensions 6 6 Double insulated, type XAC B Metal, type XAC M For control circuits Separate components: pushbuttons with analogue output (1) References 530386 Complete pushbuttons (body + operating head), non booted (2) Supply voltage Contact block Reference 0...- 15 V N/C + N/O at start of travel N/O at end of travel XEA C15361 Weight kg 0.065 0...+ 15 V N/C + N/O at start of travel N/O at end of travel XEA C25361 0.065 XEA Cp5361 Complete pushbuttons (body + operating head), booted (2) 530392 Supply voltage XEA Bp5361 Contact block Reference 0...- 15 V N/C + N/O at start of travel N/O at end of travel XEA B15361 Weight kg 0.065 0...+ 15 V N/C + N/O at start of travel N/O at end of travel XEA B25361 0.065 For use with Reference XEA Cp5361 ZA2 BZ905 XEA Bp5361 XAC X1 Colour of insert Unit reference White XAC B9111 Weight kg 0.005 Black XAC B9112 0.005 Mounting accessories 530306 Description Tightening key for fixing nut Weight kg 0.060 0.010 ZA2 BZ905 530305 Separate components and spare parts Description Booted operator (Sold in lots of 10) DF565601 XAC X1 (1) Pushbuttons providing an analogue output signal proportional to the distance travelled by the pushbutton operator. (2) Pushbutton supplied with 1 white insert and 1 black insert. XAC B9112 Dimensions XEA Bp5361 XEA Cp5361 Panel cut-out = = 30 = 26 55 = 30 (1) 18 44 E 44 E 17 0 O22,3 +0,4 26 30 55 E = support panel thickness, 1 to 3.5 mm. (1) Minimum fixing centres between 2 operators. 30076-EN.indd version: 9.3 17 References 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits Separate components and spare parts Bulbs 530307 Description 530308 DL1 Cpppp DL1 CFppp Voltage Incandescent BA 9s base fitting Maximum power: 2.6 W Maximum O: 11 mm Maximum length: 28 mm Neon BA 9s base fitting Maximum power: 2.6 W Maximum O: 11 mm Maximum length: 28 mm Unit reference 6V Sold in lots of 10 DL1 CB006 Weight kg 0.002 12 V 10 DL1 CE012 0.002 24 V 10 DL1 CE024 0.002 48 V 10 DL1 CE048 0.002 130 V 10 DL1 CE130 0.002 120 V 10 DL1 CF110 0.002 230 V 10 DL1 CF220 0.002 400 V 10 DL1 CF380 0.002 Accessories for booted operators 530311 Description Boots with circlip, without coloured insert Travel 4 mm 16 mm XAC B91p 530310 Coloured inserts for booted operators (4 and 16 mm travel) 530309 XAC B92p XAC B90p Characteristics: pages 30076/2 and 30076/4 18 Dimensions: page 30076/23 Material/ Colour Polychloroprene Operating temperature - 25...+ 70 C Sold in lots of 10 Unit reference XAC B911 Weight kg 0.002 Silicone - 40...+ 70 C 10 XAC B912 0.002 Polychloroprene - 25...+ 70 C 10 XAC B921 0.002 Silicone - 40...+ 70 C 10 XAC B922 0.002 White - 10 XAC B901 0.001 Black - 10 XAC B902 0.001 Green - 10 XAC B903 0.001 Red - 10 XAC B904 0.001 Yellow - 10 XAC B905 0.001 Blue - 10 XAC B906 0.001 Brown - 10 XAC B909 0.001 Application schemes: page 30076/24 Presentation: page 30076/26 version: 9.3 30076-EN.indd References (continued) 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits Separate components and spare parts Description 530313 530312 Complementary accessories Protective cable sleeve with cable tie (for tightening sleeve onto cable) XAC B913 530314 XAC B960 Reference Enclosures XAC B219 and XAC B220 (2 operators) For cable O 7...13 mm XAC B913 Weight kg 0.065 Enclosures XAC Bppp with 4 to 12 operators and XAC Mppp with 4 and 8 operators For cable O 10...22 mm XAC B960 0.110 For cable O 22...35 mm XAC B965 0.160 Blanking plug with seal and fixing nut - ZB2 SZ3 0.005 Adaptor for use with protective cable sleeve for cable O 10...22 mm Self-supporting cable type BBAP XAC B961 0.025 Lower support ring Single row enclosures XAC B and XAC M XAC B971 0.015 2 row enclosures XAC B XAC B972 0.020 Emergency stop pushbutton XAC B982 0.050 For use with Reference Bezels XAC X1 Weight kg 0.010 Units mounted in base of enclosure XAC X905 0.015 BA 9s base fitting bulbs XBF X13 0.003 XAC B971 DF565602 For use with Protective guards for base mounted units Tools XAC B972 DF565604 Description Tightening key Bulb extractor 530319 530318 XAC B982 XAC X1 XAC X905 30076-EN.indd version: 9.3 19 References 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M DF565666 For control or power circuits Legends 30 x 40 mm (with symbols conforming to NF E 52-124) Symbol Reference Vertical mounting 40 mm centres Raise, slow ZB2 BY4951 Weight ZB2 BY4901 0.001 Symbol Reference Vertical mounting 40 mm centres Lower, slow ZB2 BY2954 Raise, fast ZB2 BY4952 ZB2 BY4902 0.001 Raise, slow-fast ZB2 BY4953 ZB2 BY4903 Right, slow ZB2 BY4901 kg Symbol Reference Horizontal mounting 30 mm centres Weight kg 0.001 Lower, fast ZB2 BY2955 ZB2 BY2905 0.001 0.001 Lower, slow-fast ZB2 BY2956 ZB2 BY2906 0.001 ZB2 BY4907 0.001 Left, slow ZB2 BY2904 ZB2 BY2910 0.001 Right, fast ZB2 BY4902 ZB2 BY4908 0.001 Left, fast ZB2 BY2905 ZB2 BY2911 0.001 Horizontal mounting Right, slow-fast 30 mm centres ZB2 BY4903 ZB2 BY4909 0.001 Left, slow-fast ZB2 BY2906 ZB2 BY2912 0.001 Forward, slow ZB2 BY4963 ZB2 BY4913 0.001 Reverse, slow ZB2 BY2966 ZB2 BY2916 0.001 Forward, fast ZB2 BY4964 ZB2 BY4914 0.001 Reverse, fast ZB2 BY2967 ZB2 BY2917 0.001 Forward, slow-fast ZB2 BY4965 ZB2 BY4915 0.001 Reverse, slow-fast ZB2 BY2968 ZB2 BY2918 0.001 Slew right, slow ZB2 BY4919 ZB2 BY4919 0.001 Slew left, slow ZB2 BY2922 ZB2 BY2922 0.001 Slew right, fast ZB2 BY4920 ZB2 BY4920 0.001 Slew left, fast ZB2 BY2923 ZB2 BY2923 0.001 Slew right, slow-fast ZB2 BY4921 ZB2 BY4921 0.001 Slew left, slow-fast ZB2 BY2924 ZB2 BY2924 0.001 ZB2 BY4933 ZB2 BY4933 0.001 ZB2 BY4934 ZB2 BY4934 0.001 ZB2 BY4982 ZB2 BY4932 0.001 Start-Klaxon ZB2 BY4985 ZB2 BY4935 0.001 ZB2 BY4980 ZB2 BY4930 0.001 ZB2 BY2931 0.001 40 30 ZB2 BY2904 DF565665 Vertical mounting 40 mm centres Symbol Reference Horizontal mounting 30 mm centres White background, black symbol Black background, white symbol Red background, white symbol Slow Fast Klaxon Start Characteristics: pages 30076/2 and 30076/4 20 Stop Dimensions: page 30076/23 Application schemes: page 30076/24 ZB2 BY2931 Presentation: page 30076/26 version: 9.3 30076-EN.indd References 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M DF565667 For control or power circuits Legends 30 x 40 mm White Black Text Reference Red Weight kg Text Reference Weight kg b Start functions: white characters on black background b Stop functions: white characters on red background Blank Black or red background ZB2 BY2101 ZB2 BY2101 0.001 With French text ZB2 BY4101 0.001 With English text For pushbuttons DF565668 White or yellow background For pushbuttons Marche ZB2 BY2103 0.001 Start ZB2 BY2303 0.001 Arret ZB2 BY2104 0.001 Stop ZB2 BY2304 0.001 Avant ZB2 BY2105 0.001 Forward ZB2 BY2305 0.001 Arriere ZB2 BY2106 0.001 Reverse ZB2 BY2306 0.001 Montee ZB2 BY2107 0.001 Up ZB2 BY2307 0.001 Descente ZB2 BY2108 0.001 Down ZB2 BY2308 0.001 Droite ZB2 BY2109 0.001 Right ZB2 BY2309 0.001 Gauche ZB2 BY2110 0.001 Left ZB2 BY2310 0.001 En service ZB2 BY2111 0.001 On ZB2 BY2311 0.001 Hors service ZB2 BY2112 0.001 Off ZB2 BY2312 0.001 Sous tension ZB2 BY2126 0.001 Power on ZB2 BY2326 0.001 Lent ZB2 BY2127 0.001 Slow ZB2 BY2327 0.001 Vite ZB2 BY2128 0.001 Fast ZB2 BY2328 0.001 Klaxon ZB2 BY2125 0.001 - - Arret-Marche ZB2 BY2166 0.001 - - Hors-En ZB2 BY2167 0.001 Off-On ZB2 BY2367 0.001 ZB2 BY4001 0.001 ZB2 BY4005 0.001 Black White Yellow ZB2 BY4101 For selector switches - For selector switches - With special texts b Specify text when ordering, b 2 lines maximum, 11 characters per line. White characters on black background White characters on red background Other versions 30076-EN.indd ZB2 BY2002 0.001 Black characters on white background ZB2 BY2004 0.001 Black characters on yellow background Legends with texts in other languages. Please consult your Customer Care Centre. version: 9.3 21 References 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits Twin legends for tower cranes Legends with white symbols on black background Function Symbol Reference Weight kg Function Symbol Reference Weight kg 40 mm operator centres (for enclosures with 2 to 8 operators and 12 operators in 2 rows) Hoist Raise Lower XAC Y4970 0.002 Long travel Forward Reverse XAC Y4972 0.002 Slew Right Left XAC Y4971 0.002 Trolley Forward Reverse XAC Y4973 0.002 30 mm operator centres (for enclosures with 12 operators in 1 row) Characteristics: pages 30076/2 and 30076/4 22 Hoist Raise Lower XAC Y3970 0.002 Long travel Forward Reverse XAC Y3972 0.002 Slew Right Left XAC Y3971 0.002 Trolley Forward Reverse XAC Y3973 0.002 Dimensions: page 30076/23 Application schemes: page 30076/24 Presentation: page 30076/26 version: 9.3 30076-EN.indd Dimensions 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits (XAC M: products for maintenance purposes only) Pendant control stations XAC Bppp (2 to 12-way, 1 row) XAC Mppp (4 to 8-way, 1 row) XAC Bppp (12-way, 2 rows) 200 40 40 265 XAC Bppp (2 and 3-way) b 85 b1 b1 d d 74,5 b 60 c 76 c 76 100 (1) 100 (1) Protective cable sleeves internal O internal O O7 O10...13 O22...26 O9 O11 O13...16 O26...29 O16...19 O19...22 O29...32 O32...35 internal O O14 (1) With mushroom head operator. Number of operators b b1 c d 2 409 220 98 40 XAC B971, B972 30076-EN.indd 6 589 400 98 40 8 679 490 98 40 12 (1 row) 679 490 98 30 12 (2 rows) 593 404 158 40 24 Lower support rings XAC B982 48 Protective guards 4 499 310 98 40 version: 9.3 23 Pendant control stations Application schemes (typical examples) 6 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits Control circuits Contact block XES D1281 13 13 34 43 23 24 14 12 - S2 A2 - KM2 A2 A2 A1 A1 A1 - KM A2 - KM1 - KM1 A2 - KM2 A1 A1 - S2 44 14 23 24 21 12 21 22 11 - S1 - S1 22 33 For control of 2-speed reversing motor Contact block XES D1181 11 For control of single-speed reversing motor KM: high speed contactor Power circuits For control of single-speed reversing motor. 2-phase switching Application example: Combined with 3-pole isolating block XAC S399 or XAC S3991, shown in the unoperated position (pendant station "supplied"), fitted with key release trigger action latching Emergency stop operator (ZA2 BS944). L3 31 23 13 23 13 43 14 24 43 33 14 33 24 - S1 - S1 Application schemes: page 30076/24 W 34 U Dimensions: page 30076/23 V 44 W 34 V U Characteristics: pages 30076/2 and 30076/4 44 - S2 - S2 24 L3 Q 22 L2 12 L1 21 L2 11 L1 32 Contact block XES D1191 Presentation: page 30076/26 version: 9.3 30076-EN.indd Pendant control stations Application schemes (typical examples) (continued) 6 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits Power circuits (continued) For control of 2-speed reversing motor (motors with separate windings only). 2-phase switching Application example: Combined with 3-pole isolating block XAC S399 or XAC S3991, shown in the unoperated position (pendant station "supplied"), fitted with key release trigger action latching Emergency stop operator (ZA2 BS944). L2 31 32 13 12 Q 51 23 L3 23 22 L2 13 L1 L3 21 11 L1 51 Contact block XES D1291 - S2 54 52 61 24 43 52 61 33 24 43 54 14 33 14 - S1 - S1 Y 64 62 44 34 64 62 44 34 - S2 Y U1 U2 U1 U2 V1 V2 V1 V2 W1 W2 W1 W2 For control of single-speed reversing motor. 3-phase switching, reversing by 2-phase inversion Contact block XES D2201 Contact block XES D2241 with line contactor L1 L2 L3 3 2 1 A1 1 - F1 2 - S1 43 6 33 4 23 2 13 33 L3 23 13 L2 A1 - KM1 L1 44 84 34 73 24 63 34 73 14 24 63 - S2 53 14 53 - S1 30076-EN.indd 44 74 W 64 V U 54 74 Y W 64 V U 54 - S2 Y version: 9.3 25 Presentation 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits XEA B p5361 XEN C1111 XEN D2611 XEA Cp 5361 XAC B911p XAC B921p XES D1pp 1 XES B2011 ZA2 BS834 XEN D3801 ZB2 BYpppp ZA2 BS944 XEN B1181 ZB2 BY pppp ZA2 BS844 XAC S499 ZA2 BS934 XES D22p 1 ZB2 BYpppp XAC S399 ZA2 BDp XAC S41p ZA2 BGp XAC V0 p XAC B982 ZA2 BBp XAC S41p1 XAC S3991 ZA2 BV0 p ZA2 BS844 ZA2 BS944 26 version: 9.3 ZB2 SZ3 30076-EN.indd Pendant control stations Order form (specimen suitable for photocopying) 6 6 Double insulated, type XAC B Metal, type XAC M (XAC M: products for maintenance purposes only) 530343 For control or power circuits Variable composition stations, factory assembled Customer Company 7 8 3 9 4 10 Delivery date Unit reference of empty enclosure see page 30076/7 Order N Number of identical stations Enclosure price (1) XAC 12 cut-outs, centres: 40 mm 5 11 6 12 16 13 Schneider Electric Industries Sales office - Subsidiary Co. Enter the order with XAC B09 reference (for enclosures XAC B) or XAC M09 reference (for enclosures XAC M) 14 1 2 Order N Legends see page 30076/20 Contact blocks or pilot light bodies see page 30076/10 Operating heads or pilot light heads or blanking plug see page 30076/15 Reference Reference Reference Unit price Unit price Unit price Total price 1 2 525684 3 4 5 14 6 7 1 2 2 to 8 cut-outs, centres: 40 mm 9 3 4 10 11 5 6 7 8 8 12 13 15 Unit mounted in base of enclosure (if required) 13 Number of heads or blanking plugs to be fitted 525685 Factory assembled: Additional cost XAC 9VA for fitting of 1 head or 1 blanking plug X Complementary accessories, see page 30076/19 (cross the appropriate box or boxes) Description Reference Unit price 14 1 2 3 4 5 6 7 8 9 10 11 12 12 cut-outs, centres: 30 mm 14 Adaptor for self-supporting cable type BBAP for use with cable entry sleeve O 10 to 22 mm 15 Lower support ring for single row enclosures XAC B961 15 Lower support ring for 2 row enclosures XAC B972 16 Protective guard for key release latching mushroom head pushbutton, mounted in base XAC B982 XAC B971 Total price of assembled pendant station (1) Obtain the empty enclosure price. 13 15 30076-EN.indd version: 9.3 27