C-22
Connector type/1 output
・Allspecificationsaresubjecttochangewithoutnotice.
DC-AC Inverter
■Features
●1 output
●Usable in a wide range of temperatures
●Applicablepanelsize*:3to15inches
●Withbrightnesscontrolfunction(Currentdimming).
●Inthehigh-voltagegenerator(aterminalandapattern),
ananti-dustmeasurebysiliconeapplicationistaken.
(Notice)Applicablepanelsizebecomesastandard.
CXA-L0605A-VJL/CXA-L0605A-VSL
Dimming/Connector Type
CXA-L0605A-VJL/CXA-L0605A-VSLSpecifications (Please refer to each specification before use)
■Applications
F A MED MEASURE
This means that, in conformity with EU Directive
2002/95/EC, lead, cadmium, mercury, hexavalent
chromium, and specific bromine-based flame
retardants, PBB and PBDE, have not been used,
except for exempted applications.
■
Conformity to RoHs Directive
Electrical Characteristics
Other Specifications
Item Unit Symbol Specifi cation Condition
min typ max Vin(V) Vrmt(V) Vbr(V) Ta(℃) RL(kΩ) Remarks
Output Current mArms
Iout (Maximum
dimmer)
5.4 6 6.6 5±0.5 5 0 23±5 100 (*1)
5.3 6 6.7 5± 0.5 5 0 -20to+75 90to110 (*1)
Iout (Minimum
dimmer)
2.3 2.9 3.5 5±0.5 5 3 23±5 100 (*1)
Input Current A Iin - 1.2 1.5 5± 0.5 5 0 -20to+75 100 Remote ON
Oscillatory
Frequency kHz Freq 50 55 60 5± 0.5 5 0 -20to+75 90to110
Open Circuit
Voltage Vrms Vopen 1600 1800 - 5± 0.5 5 0 -20to+75 ∞ Open load
(*1) Please refer to the connection diagram for details of a dimming method.
Dimming
Function Yes
Operating
Temperature ℃ -20to+75
Storage
Temperature ℃ -30to+85
Operating
Humidity Ratio RH% 95max.
Safety
Standard ー
Weight g 14typ.
Dimensions
(WxDxH)
mm 100.5x20.3x8.0(*2)
Fused Input Yes
Remote ON / OFF
Yes
Alarm Signal
Function
No
Shutdown
Function
No
Silicone
Coating on
High Voltage
Area
Yes
(*2) These dimensions are indicated the maximum.