79
lOR D2211
REED SWITCH
ORD2211
Lamp Load
nGENERAL DESCRIPTION
nFEATURES
nEXTERNAL DIMENSIONS (Unit: mm)
nAPPLICATIONS
44.1±0.3
MAX 16.5
f0.6MAX f2.8
J2R0017-38-21
l Automotive electronic devices
l Control equipment
l Communication equipment
l Measurement equipment
l Household appliances
The ORD2211 is a single-contact reed switch designed for direct opening or closing lamps of
12 V - 3.4 W. The contacts are sealed within the glass tube with inert gas to maintain contact
reliability.
(1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive
any influence from the external atmospheric environment.
(2) Quick response
(3) The structure comprises the operating parts and electrical circuits arranged coaxially. Reed
switches are suited to applications in radio frequency operation.
(4) Reed switches are compact and light weight.
(5) Superior corrosion resistance and wear resistance of the contacts assures stable switching
operation and long life.
(6) With a permanent magnet installed, reed switches economically and easily become
proximity switches.
80
n
99.9
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
100
40 60 80 mW
AT
50

40

30

20

10

0102030405060 AT
2060
50 (12V-3.4W lamp)
0.5 (Inrush 3A)
2.5
AT
AT
mW
VDC
W
pF
VA
V
A
A
100( )
DC
AC
l ORD2211
8min
100max
200min (PI
20)
109min
0.3max
Parameter
Pull-in Value (PI)
Drop-out Value (DO)
Contact resistance (CR)
Breakdown voltage
Insulation resistance
Electrostatic capacitance
Contact rating
Maximum switching voltage
Maximum switching current
Maximum carry current
Rated value
(1) Drop-out Value vs. Pull-in Value (2) Contact resistance
Drop-out Value
Cumulative frequency percent (%)
Pull-in Value
Contact resistance
(Measurement length: 32mm)
Unit
ELECTRICAL CHARACTERISTICS
81
99.9
99
95
90
80
70
60
50
40
30
20
10
5
1
(DC100V)
0.1
1010 1011 1012 1013 1014 W
102030405060AT


400

300

200

100

0
DC:V

102030405060AT


0.4

0.3

0.2

0.1

0
pF

ORD2211 l
(3) Breakdown voltage
(5) Electrostatic capacitance
(4) Insulation resistance
Breakdown voltage
Cumulative frequency percent (%)
Pull-in Value
Insulation resistance
Electrostatic capacitance
Pull-in Value
(1MHz)
82
0.6max
0.4max
0.05max
4600±500
500
ms
ms
ms
Hz
Hz
1020304050 AT


15

10

5

0
ms
ms
0.5

0.4

0.3

0.2

0.1

0102030405060
AT
99.9
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
4100 4600 5100 Hz
l ORD2211
99.9
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
0.4
0.1 0.2 0.3 m s0
(1) Operate time
(3) Release time (4) Resonant frequency
(2) Bounce time
Parameter
Operate time
Bounce time
Release time
Resonant frequency
Maximum operating frequency
Rated value Unit
Operate time
Cumulative frequency percent (%)
Cumulative frequency percent (%)
Pull-in Value
(25Hz: 100AT energized)
(25Hz: 100AT energized)
(25Hz: 100AT energized)
Bounce time
Release time
Drop-out Value
Resonant frequency
nOPERATING CHARACTERISTICS
83
n
n
AT
60


50


40


30


20


10


0


80


60


40
PI
CR
DO
(2.27kg-10sec)

mW
ORD2211 l
99.9
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
8246 10kg0
%
40


30


20


10


0


−10


−20


−30
℃
CR
DO
PI
−40 −20 0 20 40 60 80 100 120
MECHANICAL CHARACTERISTICS
(1) Lead tensile test (static load)
(1) Temperature characteristics
(2) Lead tensile strength
Pull-in Value • Drop-out Value
Cumulative frequency percent (%)
Contact resistance
Rate of change percent
Temperature
Breaking load
Before test After test
ENVIRONMENTAL CHARACTERISTICS
84
l ORD2211

AT
60


50


40


30


20


10


0


80


60


40
PI
CR
DO
mW
AT
60


50


40


30


20


10


0


80


60


40
PI
CR
DO

mW
AT
60


50


40


30


20


10


0


80


60


40
PI
CR
DO

mW
AT
60


50


40


30


20


10


0


80


60


40
PI
CR
DO

mW
(2) Temperature cycle
(4) High temperature storage test (5) Low temperature storage test
(3) Temperature and humidity cycle
(-55 to 125 )
-10 to 65
80% to 98%
Pull-in Value • Drop-out ValueContact resistance
Pull-in Value • Drop-out ValueContact resistance
Pull-in Value • Drop-out ValueContact resistance Pull-in Value • Drop-out ValueContact resistance
Before test After test
Before test After test Before test After test
Before test After test
(+125-500H) (-40℃-500H)
85
ORD2211 l
1500






1000






500
G
AT



AT
60


50


40


30


20


10


0


80


60


40
PI
CR
DO

mW
AT
60


50


40


30


20


10


0


80


60


40
PI
CR
DO

mW
1002030405060
(6) Shock test
(7) Vibration test
2) Misoperation area
Pull-in Value • Drop-out Value
Acceleration
Misoperation
area
Pull-in Value
Contact resistance
Before test After test
Pull-in Value • Drop-out ValueContact resistance
Before test After test
(20G: 101000Hz)
(30G: 11ms)
1) Electrical characteristics
(openclose)
86
nLIFEEXPECTANCYDATA:ORD2211
13, 14, 16VDC
12V-3.4W Lamp
50VDC
1A
6VDC
10mA, 50mA
5
10
1
90
70
50
30
0.1

50mA 10mA

99.9
0235710
623 5710
723 5710
823 5710
9
%)
5
10
1
99.9
90
70
50
30
0.1
0235710
4
23 57 10
5
23 57 10
6
23 57 10
7
%)
l ORD2211
5
10
1
99.9
90
70
50
30
0.1
14V
13V
16V
0235710
4
23 57 10
5
23 57 10
6
23 57 10
7
%)
No failure
No failure
Load conditions
Voltage:
Current:
Cumulative failure rate
Number of operations
* Arrow indicates number
of operations where test
was completed.
Load conditions
Voltage:
Current:
Load: Resistive load
Cumulative failure rate
Number of operations * Arrow indicates number
of operations where test
was completed.
Load conditions
Voltage:
Current:
Load: Resistive load
Cumulative failure rate
Number of operations