Technical Data 2034
Effective December 2017
Supersedes September 2014
Product features
•UL Recognized: E19180
•CSA: 053787
PC-Tron
Subminiature radial leaded fast-acting fuses
•Radial leaded, fast-acting thru-hole fuse
•Ideal for high voltage DC applications
•Board washable
•Optional mounting socket available (PCS)
•Available in different lead configurations
Agency information
•Specify packaging code prefix, product and option code suffix
Ordering information
BK PCB- 1/2 -R
Packaging Code Prefix
Fuse Series
Amp Rating
Option Code Suffix
DC Application
The PC-Tron subminiature fuse is UL Recognized for DC
supplementary overcurrent protection to provide individual
protection for components or internal circuits in equipment.
Suitability for a specific application is dependent on time
constants and capacitance values. It is the responsibility of the
customer to evaluate the information provided for applicability
to their particular application.
•PCS Mounting Socket (RoHS compliant): Available as option.
Specify catalog number BK/PCS (100 in a polybag) and short fuse lead
length — PCC or PCE
Specifications
Lead AC Voltage AC DC Voltage DC Interrupting
Catalog Number Length Rating Interrupting Rating Min. Max.
PCB-
1
/
2
,
3
/
4
, 1, 1-
1
/
2
, 2, 2-
1
/
2
Full - 0.750" (straight) 250V 50A@250V - 10kA@125V 450V 300 5900A
PCB-3 Full - 0.750" (straight) 250V 50A@250V 450V 300 4400A
PCB-4 Full - 0.750” (straight) - - 450V 300 2500A
PCC-
1
/
2
,
3
/
4
, 1, 1-
1
/
2
, 2, 2-
1
/
2
Short 0.100" (straight) 250V 50A@250V - 10kA@125V 450V 300 5900A
PCC-3 Short 0.100" (straight) 250V 50A@250V - 10kA@125V 450V 300 4400A
PCC-4 Short 0.100" (straight) - - 450V 300 2500A
PCD-5 Full - 0.750" (straight) 125V 10kA@125V 400V 300 1000A
PCE-5 Short 0.100" (straight) 125V 10kA@125V 400V 300 1000A
PCF-
1
/
2
,
3
/
4
, 1, 1-
1
/
2
, 2, 2-
1
/
2
0.475" 250V 50A@250V - 10kA@125V 450V 300 5900A
PCF-3 0.475" 250V 50A@250V - 10kA@125V 450V 300 4400A
PCG-5 0.475" 125V 10kA@125V 400V 300 1000A
PCH-
1
/
2
,
3
/
4
, 1, 1-
1
/
2
, 2, 2-
1
/
2
0.125" 250V 50A@250V - 10kA@125V 450V 300 5900A
PCH-3 0.125" 250V 50A@250V - 10kA@125V 450V 300 4400A
PCH-4 0.125" - - 450V 300 2500A
PCI-5 0.125" 125V 10kA@125V 400V 300 1000A
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required
ambient temperatures.
AC Time-Current Characteristics
% of Amp Rating Opening Time
100% 4 hours minimum
200% 10 second maximum