HG2G 5.c7h in Operator Interface World Class, Super Bright LCD Monitor Available with Ethernet (10/100BASE-T) interface and other network communications. Housing color: Silver Housing color: Light gray (090526) Housing color: Dark gray Enhanced visibility and userStylish design with 3 different 5.7 inch 320 x 240 Pixels Super Bright 350 cd/m 2 * High contrast, Wide viewing angle 256 colors, Color LCD Contrast comparison: 1.7 times brighter than competitive models Viewing angle: From top 65, from bottom 70, from right/left 55 Panel Depth Only 35.9 mm (Housing) 35.9 mm Housing color: Silver Super Bright 500 cd/m 2 * High-quality monochrome 15 brightness levels Monochrome LCD Contrast comparison:5 times brighter than competitive models Viewing angle: From top 25, from bottom 45, from left/right 45. Housing color: Dark gray *Luminance according to LCD manufacturer's specifications STN Color 256 2 STN Monochrome 15 levels Touch Panel Analog User Memory 2MB Serial Communication RS232C RS485 (422) Ethernet 10/100 BASE-T Thin 35.9mm (Panel Depth) Body Color Light Gray Dark Gray Silver CE Marked UL/c-UL Listed (090526) friendly features. housing colors. HG2G Operator Interface Execute several operations using only one button By overlapping the screens, common graphic images can be shared. Multi-button functionality allows operation of several functions at the same time. Five base screens can be overlapped onto one base screen and up to three pop-up sub screens can placed on top. Effective design is possible by creating a layout screen and sharing graphics used in multiple screens. Up to 32 functions can be set in one button so there is no need to overlap buttons. Bit write, word write, and script commands can be set in one button, reducing design time. Word Write Sub screens Script Bit Write Sub screens pop-up Switch Screens Easily design and edit screens Complicated operations are strain on the host machine Base screen Complicated operation can be processed inside the HG2G using script functions. Flexible screen design Button positioning and size can be adjusted. Various operations can be processed inside the HG2G, reducing the strain on the host machine. Conditional statements and functions can be selected and entered from the function list using the script function, allowing beginners to enter functions easily. Syntax check function is also available. Solve system errors quickly The position and size of a touch button can be changed as required. Operation log functions and alarm log functions record operational details. The touch button can be moved and re-sized in 1-pixel increments. The Operation Log records information for every operation. This function enables you to check who, when, what, and where an operation was performed. The alarm log function displays an alarm when a system error occurs and stores the log data. These functions help analyze causes and solve problems such as system errors. The log data can be exported as a CSV file. Display foreign languages Upload alarm log data Multiple languages can be displayed by using the language change function. Switch to any of 16 different languages by simple operation. Text can be edited by the text manager of WindO/I-NV2. Text can also be edited using Excel and can be imported using CSV and TEXT files. European, Japanese, Chinese, Taiwanese, Korean, Central European, Baltic, Cyrillic, and Windows fonts can be installed. WindO/I-NV2 or Downloader Operation Log Example Time User Name Screen No. 2009/01/23 01:34:07 English Japanese Display and analyze log data -- 2009/01/23 01:34:08 -- 2009/01/23 01:34:08 test1 Event Name Part Name Device Changed to Base 1 Change Operation Modes -- -- Base 1 Change Users -- -- test1 Base 1 Switch Base Screens -- -- Base 1 BitSwitch1 -- -- -- LM 0 1 2009/01/23 01:34:13 test1 Base 1 Press Buttons 2009/01/23 01:34:13 test1 Base 1 Write Data to any Devices Alarm Log Display Run Mode Countermeasure Screen Chinese Features System Software Download Download via O/I Link Device Monitor Font Download Simulation Pass-through Function Download via Ethernet (090526) Switching Text Groups Alarm Log Preventive Maintenance Overlapping Screens Scripts Logging Data Recipe Popup Screen Superimpose Function Trigger Condition Setting of Parts Operation Log Function Password Setting 3 Interface Adaptable to various communication systems for flexible system architecture. maintenance is possible using a PC located in a remote location. Ethernet Connection HG2G Communicates with PLCs via host communication. Screen display data can be changed and data can be analyzed from remote locations using a PC. Connected to a PLC that can be used via Ethernet. Flexible system architecture. Both 1:1 communication and N:N communication are possible. Configuration Software (Ethernet Communication Drivers) IDEC: Web Server Unit (FC3/FC4/FC5 series), Mitsubishi: MELSEC-Q/QnA (Ethernet) A-B: Ethernet/IP Modicon: Modbus/TCP Koyo: DirectLogic When connecting several PLCs, the PLCs must use the same ethernet protocols. PLC Host Device Serial Connection PLC Link Communication PLC Connects to a variety of devices such as PLCs, computer boards, and barcode readers. Serial 1 Ethernet Data can be read from and written to PLC devices, such as relays and registers. Various communication device drivers are available. Serial 1 DM Link Communication PC, PLC, and computer boards can access the DM link memory in the HG2G to read and write data. 1:1 and 1:N communication systems are possible. Because a proprietary communication protocol is used for the HG2G, the host requires a special program for DM link communication. 1:1 Communication Host Device RS232C RS485 (422) Ethernet O/I Link Communication 1:N Communication RS232C RS485 (422) Host device such as PC, PLC, and computer board. O/I Link Host device such as PC, PLC, and computer board. User Communication/Sub Host Communication Up to 16 HG2G units can be connected with the O/I link User Communication Connect to serial comat a communication speed of 115.2 kbps. munication devices such as barcode readers. Master Slave 1 Slave 2 Up to 3 units can be connected (without host). Host Device O/I Link RS232C RS485 (422) Only one HG2G can be connected using RS232C Serial 1 Serial 2 O/I Link Sub Host Communication A communication method for reading and writing data from and to devices such as PLC relays and registers. Using Sub Host Communication with PLC Link Communication makes it possible to communicate with two PLCs without making a communication program in the PLC. Up to 15 slaves can be connected O/I link unit is not required for the HG2G slave. Operator interfaces other than HG2G cannot be connected. (Communication Protocol) IDEC MicroSmart Modbus RTU PLC Link Communication Sub Host Communication Interface Specification Ethernet Serial 1 Serial 2 O/I Link 4 Ethernet Interface 10/100Base-T compliant, communicates with host devices such as a PLC or PC and can be used to download screen data to the HG2G. Terminating Resistor Selector Switch Serial Interface 1 Communicates to the host using either RS232C or RS485 (422). Serial Interface 2 Communicates with a PC using RS232C, enabling HG2G maintenance. This port can also be used as an interface for user or sub host communications. O/I Link Interface By attaching an optional O/I link unit, up to 16 HG2G units can be connected to one host device using the O/I link communication system. High-speed communication of 115.2 kbps Battery Serial Interface 2 RS232C O/I Link Interface O/I Link Unit (optional) HG9Z-2G1 Serial Interface 1 RS232C/RS485/RS422 (RS232C/RS485/RS422 interfaces cannot be used simultaneously) Ethernet Interface 10/100BASE-T Serial 2 O/I Link Serial 1 Ethernet Power Terminals 24V DC (090526) Software User-friendly features enable easy graphical screen editing. Application Software Automation Organizer Automation Organizer is a complete package software to create system configuration and edit and debug programs for PLCs and operator interfaces. Automation Organizer consists of system configuration software "WindCFG," PLC programming software "WindLDR," and OI touchscreen programming software "WindO/I-NV2." OI Touchscreen Programming Software Flexible workspace allows for dynamic screen design Tag Editor Project Window Device addresses of the connected PLC and HG series are displayed. A tag name can be set to each address and the name can be changed by the user. Structure of projects: such as screen, project, alarm log, and text managers are easy to recognize and settings are easy to edit. Part List Button and lamp parts can be displayed. Layout is possible by using drag and drop methodology. Screen List Created screens can be seen as images, making it easy to open screens that need editing. Easy Setting of Parts Operating Conditions Object List Device, operating condition, and type of command can be read from this list. A property can also be changed by selecting the item. Automatic Adjustment of Text Size The text size is automatically adjusted according to the size of the object such as a button nameplate. The text size fits in the object even when the language is switched from English to a different language. Confirm Images on the WindO/I-NV2 Screen The operating conditions of buttons and lamps, bit/word write, and screen switching can be set in the property settings for each part. Lamps can be easily set to turn on, turn off, or flash. Easy to confirm the screen image before and after switching screens and texts on the WindO/I-NV2 screen. Powerful screen editing. Preview (when off) Preview (when on) Select from 5000 images in the image library Download Service Latest versions of WindO/I-NV2, host interface drivers, and user's manual can be downloaded from the IDEC website. Update your HG2G system software by downloading the latest functions using WindO/I-NV2. http://www.idec.com/download Various graphic images can be selected from WindO/I-NV2 configuration software and Symbol Factory, a graphic library containing 5000 images. (090526) 5 HG2G Operator Interface Brightest LCD in its class. Can be used with various interfaces including Ethernet. * Super-bright LCD. Can be seen clearly--even in bright locations. * Ethernet communication is available. * Easy system configuration with various communication systems, such as PLC link communication. * Easy-to-use design tool WindO/I-NV2 * Slim body style--only 35.9mm deep behind the panel (housing) * Components can be laid out easily on the analog touch panel. * Light gray, dark gray, and silver housing colors are available. * Multi-lingual fonts can be displayed by switching text groups. * Operation log function is provided. Types Operation Type Display Screen Maintenance Interface Ethernet Interface Host Interface With 5.7-inch STN monochrome LCD 15 shades Analog switch RS232C With 5.7-inch STN color LCD 256 colors **Options Name Ordering Type No. HG2G-SB22TF-W Silver HG2G-SB22TF-S Light gray HG2G-SB22VF-W HG2G-SB22VF-B Light gray HG2G-SS22TF-W Silver Silver Light gray Dark gray Silver Package Quantity Remarks HG2G-SB22TF-B Dark gray Dark gray Without Type No. Light gray Dark gray Without RS232C/485 (422) Detachable 9-pin terminal block Housing/Bezel Color HG2G-SB22VF-S CE HG2G-SS22TF-B HG2G-SS22TF-S HG2G-SS22VF-W HG2G-SS22VF-B HG2G-SS22VF-S Description Protective Sheet PLC Connection Cable For IDEC MicroSmart (5m) PLC Connection Cable For IDEC MicroSmart (2.4m) O/I Link Unit HG9Z-2D2 5 For HG2G HG9Z-XC275 1 Mini DIN 8-pin FC2A-KP1C 1 Mini DIN 8-pin HG9Z-2G1 1 Maintenance Cable HG9Z-XCM22 1 Application Software "Automation Organizer" (CD) (English/Japanese/Chinese) SW1A-W1C 1 Manual "WindO/I-NV2" HG9Y-B1119 1 Communication unit for O/I link Dsub 9-pin (socket) (2m long) Computer link cable 4C (FC2A-KC4C) for IDEC's MicroSmart and OpenNet Controller is also compatible. Complete package includes Wind CFG system configuration software, WindLDR PLC programming software, and WindO/I-NV2 OI Touchscreen programming software. PDF files of English/Japanese/Chinese manuals are stored on the CD. English **Replacement Parts Name Type No. Ordering Type No. Package Quantity Mounting Clip SLD-K02 SLD-K02PN10 10 Replacement Battery HG9Z-XR1 HG9Z-XR1 1 Host communication plug HG9Z-XT09 HG9Z-XT09 1 6 Description Four clips are supplied with HG2G. Lithium battery CR2032 (one battery is supplied with HG2G) One plug is supplied with HG2G. (090526) HG2G Operator Interface General Specifications Rated Power Voltage 24V DC Power Voltage Range 20.4 to 28.8V DC Power Consumption 10W maximum Allowable Momentary Power Interruption Display Specifications Display Color 20A maximum 1000V AC, 10 mA, 1 minute between power and FG terminals 50 M minimum between power and FG terminals (500V DC megger) Dielectric Strength Insulation Resistance Operating Temperature 0 to 50C (no freezing) Operating Humidity 10 to 90% RH (no condensation) Storage Temperature -20 to +60C (no freezing) Storage Humidity 10 to 90% RH (no condensation) Pollution Degree 2 (IEC 60664-1) Shock Resistance Noise Immunity Electrostatic Discharge Corrosion Immunity Free from corrosive gases Mounting Panel mounting Degree of Protection IP65 (operator) Dimensions 167.2W x 134.7H x 40.9D mm Weight (approx.) 500g 320W x 240H pixels Backlight Cold-cathode tube Backlight Control Automatic OFF Contrast Adjustment 0.2 to 0.8N Mechanical Life 1,000,000 operations Acknowledge Sound Electronic buzzer Battery Life 20 characters x 15 lines Full size Double size 1/2 size 40 characters x 15 lines Double size 10 characters x 7 lines 0.5, 1, 2, 3, 4, and 8 vertically and horizontally Blink (1 or 0.5 sec period), reverse, bold, shadowed Straight line, polyline, rectangle, circle, ellipse, arc, pie, equilateral polygons (3, 4, 5, 6, 8), paint, bitmap image 3 popup screens + 1 system screen Window Display Note: The backlight life refers to the time until the surface brightness reduces by half after using continuously at room temperatures. Electrical Characteristics RS485/RS422 Base screen, sub screen, system screen Base screen: 3000 max. Sub screen: 3015 max. Bit Button, Word Button, Goto Screen, Print Button, Key Button, Multi Button, Keypad, Selector Switch, Potentiometer, Numerical Input, Character Input, Pilot Lamp, Multi-State Lamp, Picture Display, Message Display, Message Switching Display, Alarm List Display, Alarm Log Display, Numerical Display, Bar Graph, Trend Chart, Pie Chart, Meter, Calendar, Bit Write Command, Word Write Command, Goto Screen Command, Print Command, Screen Script Command, Multi Command, Timer Year, Month, Day, Hour, Min., Sec., Day of Week 60 sec per month (at 25 C) Calendar, log data, keep internal relay, keep internal register 4 years (at 25C) Dimensions Synchronization EIA RS232C compliant 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps Asynchronous Control System Hardware control or none Electrical Characteristics Synchronization EIA RS485 (422) compliant 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 187500 bps Asynchronous Control System Hardware control or none Transmission Speed Communication Method Connector Serial Interface 1 2 MB (including expansion fonts) Power Failure Backup Data Full size 1/2 size Graphics Type Function Specifications Calendar 1/4 size Impossible (by IDEC only) 8 x 8 pixels (Western European language: ISO 8859-1, Central European language: ANSI 1250, Baltic: ANSI 1257, Cyrillic: ANSI1251, Japanese katakana and symbols: JIS 8-bit code) 8 x 16 pixels (Western European language ISO 8859-1, Central European language: ANSI 1250, Baltic: ANSI 1257, Cyrillic: ANSI1251, Japanese katakana and symbols: JIS 8-bit code) 16 x 32 pixels, 24 x 48 pixels, 32 x 64 pixels (Western European language: ISO 8859-1) 16 x 16 pixels (Japanese JIS first and second level characters, simplified Chinese, traditional Chinese, Korean) 32 x 32 pixels (Japanese JIS first level characters, Mincho font) 40 characters x 30 lines RS232C Analog resistive membrane Operating Force Parts 256 colors 75,000 hours nominal (Note) Backlight Replacement Quantity of Characters Color Possible in steps Backlight Life Display Character Size Color STN Interface Specifications Switching Element User Memory Display Resolution 115.2W x 86.4H mm Character Attribute General Specifications No. of Screens Monochrome 15 shades Character Magnification * Do not use the HG2G in an environment subject to strong ultraviolet rays, otherwise the LCD quality will deteriorate. Screen Types Color/Shade 1/4 size 5 to 9 Hz amplitude 3.5 mm, 9 to 150 Hz, acceleration 9.8 m/s2 10 cycles (100 minutes) on each of three mutually perpendicular axes) (IEC60068-2-6) 147 m/s2, 11 ms 5 shocks on each of three mutually perpendicular axes (IEC60062-2-27) Fast transient/burst test, Common mode: Level 3, Power terminals: 2 kV, Communication line: 1 kV (IEC 61000-4-4) ESD-3 (RH-1), Level 3 (contact 6 kV, air 8 kV) (IEC 61000-4-2) Vibration Resistance Monochrome STN Effective Display Area 10 ms maximum Inrush Current Monochrome Effective Display Area Transmission Speed Communication Method Connector Electrical Characteristics Serial Interface 2 Transmission Speed Synchronization Communication Method Ethernet Detachable 9-pin terminal block Half or full duplex Detachable 9-pin terminal block EIA RS232C compliant 9600, 19200, 38400, 57600, 115200 bps Asynchronous Half duplex, proprietary protocol Connector Mini DIN 8-pin connector Transmission Speed 19200, 38400, 57600, 115200 bps Electrical Characteristics O/I Link Communication Half or full duplex Synchronization Communication Method EIA RS485 compliant Asynchronous Half duplex, proprietary protocol Connector 3-pin terminal block Connector Modular connector (RJ-45) Interface IEEE802.3 (10/100BASE-T) compliant Panel Thickness 1.6 to 5.0 5.0 2 0 35.9 40.9 167.2 152.5 All dimensions in mm. (090526) 121 4.2 153 120.0 134.7 Panel Cut-out 2 0 * Install the HG2G into a panel cutout by tightening the four mounting clips to a torque of 0.12 to 0.15 N*m (recommended tightening torque: 0.14 N*m). Note: Do not tighten with excessive force, otherwise the HG2G and screen will be distorted. Also waterproof characteristics may be lost. 7 Compatible PLCs Manufacturer Series OpenNet Controller MicroSmart IDEC MicroSmart Pentra MELSEC-A MELSEC-QnA Mitsubishi MELSEC-Q MELSEC-FX SYSMAC-C OMRON SYSMAC-CS1 SYSMAC-CJ SYSMAC-CP PLC-5 SLC-500 AllenBradley MicroLogix ControlLogix CompactLogix FlexLogix S7-200 SIEMENS S7-300 S7-400 Applicable CPU Unit CPU Connection Link Unit Ethernet FC3A-CP2 FC4A-C10R2 FC4A-C16R2/C24R2, FC4A-D20K3/D20S3, FC4A-D20RK1/D20RS1, FC4A-D40K3/D40S3 FC5A-C10R2/C16R2, FC5A-C24R2, FC5A-C10R2C/C16R2C, FC5A-C24R2C FC5A-D16RK1/D16RS1 FC5A-D32K3/D32S3 A1N, A2N, A3N, A1SH A2CCPUC24 A0J2, A0J2H, A2A, A3A, A2U, A3U, A4U, A2US, A2USH-S1 Q4ACPU, Q4ARCPU, Q3ACPU, Q2ACPU, Q2ACPU-S1 Q2ASHCPU, Q2ASHCPU-S1, Q2ASCPU, Q2ASCPU-S1 Q00CPU, Q01CPU Q02CPU, Q02HCPU Q06HCPU, Q12PHCPU, Q25HCPU Q00JCPU FX0, FX0N, FX1, FX2, FX2C, FX-0S, FX-1S FX2N, FX2NC, FX1N, FX1NC FX3UC, FX3U C500, C500F, C1000H, C1000HF, C2000, C2000H, C200HS, C200HE, C200HG, C200HX, C120, C120F C20H, C28H, C40H, C60H, CQM1H, C200HS-CPU21/23/31/33, C200HE-CPU42, C200HG-CPU43/63, C200HX-CPU44/64 CPM1, CPM1A CPM2A CS1G, CS1H CJ1M, CJ1H, CJ1G CP1H Any PLC-5 models connectable to 1770-KF2 Any PLC-5 PLC-5, PLC-5E SLC5/03, SLC5/04 SLC5/05 MicroLogix1000 MicroLogix1100 MicroLogix1200 MicroLogix1500 ControlLogix5550 ControlLogix5555 1768CompactLogix 1769CompactLogix 1794-L33, 1794-L34 CPU212, CPU214, CPU215, CPU216, CPU221, CPU222, CPU224, CPU226 CPU224XP, CPU226XM CPU313, CPU314, CPU315, CPU315-2DP, CPU316, CPU318 CPU313C-2PtP CPU412, CPU414, CPU416, CPU416F-2, CPU417 Manufacturer Keyence Sharp JTEKT (TOYODA) Toshiba Hitachi GE Fanuc Automation Schneider Modicon Panasonic Yaskawa Series KV-700, KV-1000 KV-700, KV-1000 KZ KZ-10, 16, 20, 40, 80 KV KV-10, 16, 24, 40 JW-10 JW-21CU, JW-31CUH/H1, JW-50CU/CUH New Satellite JW JW-22CU, JW-32CUH/H1, JW-33CUH/H1/H2/H3, JW-70CU/CUH, JW-100CU/CUH S10mini S10mini S10V LQP510 TOYOPUC-PC2J PC2J TOYOPUC-PC3J PC3J, PC3JD, PC3JG TC200 TC3-13B1 TCmini TC03-01, TC03-02 CPU311, CPU313, CPU323 CPU331, CPU341, CPU350, Series 90-30 CPU351, CPU352, CPU360, CPU363, CPU364, CPU374 VersaMax Nano Micro (14, 23, 28 points) TWDLCAA16DRF Twido TWDLCAA24DRF Momentum 171CCC96020 FP0, FP10, FP10SH, FP1, FP series FP2, FP2SH, FP Machine MP920, MP930, MP2300 Controller DirectLOGIC05 DirectLOGIC06 Koyo DirectLOGIC205 KOSTAC SZ KOSTAC SU FANUC Yokogawa Power Mate Series FACTORY ACE FREX-PC Fuji MICREX-F PROSEC T Series Toshiba V Series LS Industrial Systems CPU Unit MASTER-K DL05 DL06 D2-240, D2-250, D2-250-1, D2-260 SZ-4 SU-6H SU-5E, SU-6B SU-5M, SU-6M Power Mate-MODEL D 16i, 160i, 18i, 180i 30i, 31i, 32i FA-M3 (F3SP20, F3SP28, F3SP30, F3FP36, F3BP20, F3BP30) FA-M3 (F3SP05, F3SP21, F3SP25, F3SP35, F3SP38, F3SP53, F3SP58) NB1, NB2, NB3, NJ-CPU-E4, NJ-CPU-A8, NJ-CPU-B16, NS F30, F50, F50H, F55, F60, F70, F70S, F80H, F81, F120H, F120S, F140S, F150S, F250 T1-16, T1-28, T1-40, T1-40S, PU234E PU224, PU215N, PU235N, PU245N, PU315, PU325, PU325H, PU326H PU672T, PU662T, PU612E L1PU11H, L1PU12H, S2PU82, S2PU72, S2PU32, S2PU22, S3PU65, S3PU55, S3PU45, S3PU21 K10S1, K120S K80S, K200S K300S CPU Connection Link Unit Ethernet * Ethernet link unit may be necessary for some PLCs. The updated information of the compatible PLCs can be found at the following website. http://www.idec.com/download Windows and Excel are registered trademarks of Microsoft Corporation, USA in the USA and other countries. Safetey Precautions Read the safety precautions described in the user's manual to make sure of correct operation of the HG2G. Specifications and other descriptions in this catalog are subject to change without notice. 7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan Tel: +81-6-6398-2571, Fax: +81-6-6392-9731 E-mail: marketing@idec.co.jp IDEC CORPORATION (USA) 1175 Elko Drive, Sunnyvale, CA 94089-2209, USA Tel: +1-408-747-0550 / (800) 262-IDEC (4332) Fax: +1-408-744-9055 / (800) 635-6246 E-mail: opencontact@idec.com IDEC CANADA LIMITED 3155 Pepper Mill Court, Unit 4, Mississauga, Ontario, L5L 4X7, Canada Tel: +1-905-890-8561, Toll Free: (888) 317-4332 Fax: +1-905-890-8562 E-mail: sales@ca.idec.com IDEC AUSTRALIA PTY. LTD. 2/3 Macro Court, Rowville, Victoria 3178, Australia Tel: +61-3-9763-3244, Toll Free: 1800-68-4332 Fax: +61-3-9763-3255 E-mail: sales@au.idec.com IDEC ELECTRONICS LIMITED www.idec.com (090526) Unit 2, Beechwood, Chineham Business Park, Basingstoke, Hampshire RG24 8WA, UK Tel: +44-1256-321000, Fax: +44-1256-327755 E-mail: sales@uk.idec.com IDEC IZUMI (H.K.) CO., LTD. IDEC ELEKTROTECHNIK GmbH Wendenstrasse 331, 20537 Hamburg, Germany Tel: +49-40-25 30 54 - 0, Fax: +49-40-25 30 54 - 24 E-mail: service@idec.de IDEC (SHANGHAI) CORPORATION Room 608-609, 6F, Gangtai Plaza, No. 700, Yan'an East Road, Shanghai 200001, PRC Tel: +86-21-5353-1000, Fax: +86-21-5353-1263 E-mail: idec@cn.idec.com IDEC TAIWAN CORPORATION 8F-1, No. 79, Hsin Tai Wu Road, Sec. 1, Hsi-Chih, Taipei County, Taiwan Tel: +886-2-2698-3929, Fax: +886-2-2698-3931 E-mail: service@tw.idec.com IDEC (BEIJING) CORPORATION Room 211B, Tower B, The Grand Pacific Building, 8A Guanghua Road, Chaoyang District, Beijing 100026, PRC Tel: +86-10-6581-6131, Fax: +86-10-6581-5119 IDEC IZUMI ASIA PTE. LTD. IDEC (SHENZHEN) CORPORATION Unit AB-3B2, Tian Xiang Building, Tian'an Cyber Park, Fu Tian District, Shenzhen, Guang Dong 518040, PRC Tel: +86-755-8356-2977, Fax: +86-755-8356-2944 Units 11-15, Level 27, Tower 1, Millennium City 1, 388 Kwun Tong Road, Kwun Tong, Kowloon, Hong Kong Tel: +852-2803-8989, Fax: +852-2565-0171 E-mail: info@hk.idec.com No. 31, Tannery Lane #05-01, HB Centre 2, Singapore 347788 Tel: +65-6746-1155, Fax: +65-6844-5995 E-mail: info@sg.idec.com Cat. No. EP1264-0-1 MAY 2009 PDF