DPS-180AB-21
Input
Voltage Range 100~264Vac Auto Range
Frequency 47~63Hz
Efficiency The average efficiency at 25%, 50%, 75% and
100% load/115Vac 60Hz/230Vac 50Hz 88%
Input Current 100Vac /12V/2A load 2.5A
240Vac /12V/2A load 1.25A
Output 24Vdc 0A ~ 7.5A
Protection
Over-current Latch-off
Over-temperature Latch-off
Short Auto Restart
Over-voltage Latch-off
Environment
Operating Temp. 0 to 50
Storage Temp. -20 to 80
Operating Humidity 20% - 80%
Storage Humidity 10% - 90%
FEATURES
Total Power 180W,peak 288W for 4Sec.
EfficiencyMeet DoE level VI
High Reliability:>100,000 Hours @ 25
ProtectionShort / Over-current / Over-voltage
/Over-temperature
SafetyCE/FCC/TUV-GS/UL/CUL/CB
EMICLASS B
85 (W) x 40 (H) x 170 (L) mm
Size(L x W x H) 170*85*40 mm
AC Input Connector C14
DC Output Connector 4 PIN DIN
The de-rating curve of ambient temperature shown as Fig.1.
Fig.1 Ambient temperature to power de-rating curve