MIT515, MIT525, MIT1025 5-kV and 10-kV dc Insulation Resistance Testers MIT515, MIT525, MIT1025 5-kV and 10-kV Insulation Resistance Testers DESCRIPTION The new range of insulation resistance testers consists of three models: two 5 kV units (MIT515 and MIT525) and a 10 kV unit (MIT1025). Resistance measurement is available up to 10 T for the 5 kV models and 20 T for the 10 kV model. The new instruments are smaller and lighter than previous models yet offer advanced features and rapid charge capability. A key productivity feature is the ability to take measurements when connected to line power/mains with a dead battery. Intelligent battery charging ensures the optimum charge rate as a function of battery level, resulting in minimum charge times. The rugged, unique dual case design provides the ultimate protection for a portable instrument and a clip-on lead pouch ensures that leads remain with the instrument at all times. The case lid is removable for improved terminal access. IP rating is IP65 with the case closed preventing water/dust ingress. High reliability and safety are built in; all models are safety rated to CATIV 600 V and are double insulated. Five preset voltage ranges are provided in insulation test mode, plus a user settable lock voltage range. Any selectable test voltage may be locked and restored via the selector switch, thereby increasing efficiency of commissioning and repetitive tests. Preconfigured diagnostic tests include Polarization Index (PI), Dielectric Absorption Ratio (DAR), dielectric discharge (DD), Step Voltage (SV) and ramp test. n Industry best guard terminal accuracy n Compact and lightweight for easy transport and use PI, DAR, DD, SV and ramp test Unique dual case design provides additional user protection Lithium-ion battery - extended capacity, rapid charge Advanced memory with time/date stamp CATIV 600 V safety rating on all terminals The ramp function gradually increases voltage up to a selected level while graphing current vs. voltage (graph downloadable). Graphs can be compared to example curves in IEEE 95-2002 to reveal a variety of faults difficult to detect otherwise. Small defects can be easily detected without risking the sudden large voltage increments produced by a Step Voltage test. Monitoring the developing graph during test enables the operator to terminate prior to breakdown, thereby reducing the possibility of damage to already flawed insulation. These units are particularly informative on polyester, asphalt and epoxy-mica insulations. They can also test voltage suppression devices. Simplicity of operation is achieved with two rotary switches and the large backlit display enables multiple results to be displayed simultaneously. Advanced memory storage includes time/date stamping of results, logging of data and recall of results to screen. A fully isolated USB device interface (type B) is used for safe transfer of data to Megger's PowerDB asset management software. Typical end users include: Electrical contractors Testing Wind and service companies farm and solar generation operators Power generation and distribution companies Industrial Rail companies companies MIT515, MIT525, MIT1025 5-kV and 10-kV dc Insulation Resistance Testers FEATURES AND BENEFITS Smaller size and lighter weight allows easier transport and use without compromising performance. Locking test leads provide additional safety. 3 mA short circuit current with unique max power regulations technology ensures maximum transfer whatever the load until selected voltage is reached. 5% accuracy all the way up to 1 T-ohm at 5 kV and 2 T-ohm at 10 kV ensures highest accuracy where it matters most. Date and time-stamped test results reduce the risk of error in result interpretation. High measurement range enables installation testing and long-term trending of higher value apparatus. Unique dual case design allows for fire-retardant protection while maintaining ruggedness. High-quality, flexible silicon test leads meet safety regulations of IEC 61010-31:2008 while ensuring measurement accuracy. Timed IR plus PI, DAR, DD, SV and ramp tests maximize diagnostic testing capability. Operate from line power when battery fully discharged (charges while operating). Two and one-half hour full battery charge time (one-half hour charge for one hour testing) significantly increases productivity. APPLICATIONS The units are designed for testing the insulation of highvoltage electric equipment. Their wide voltage range also allows applications for low-voltage equipment. Generators, motors, transformers, cables and switchgear all require effective maintenance. The test techniques on the instruments provide valuable diagnostic information. Up to six hours continuous testing (5 kV) on a single battery charge. n Industry best guard terminal performance to insure highest accuracy of measured values. All three instruments test the insulation resistance of: n High-voltage power cables and high-voltage buses n Large motor/generator windings n Line and substation transformers n Enhanced driver technology provides plug-and-play when connected to the internet. No tedious and potentially interruptive setup procedures. The MIT525 and MIT1025 also perform spot tests, stepvoltage tests, dielectric discharge tests, ramp tests, and dielectric absorption tests for the following applications: Dedicated voltmeter function (30 V to 660 V) with frequency measurement allows the user to check for induced voltages. n Acceptance testing at installation to check conformance to specifications. n Routine preventive/predictive maintenance testing after installation. CATIV 600 V safety rating on all terminals allows for safe use in the widest range of applications. n QA testing as part of the manufacturing process. Large LCD with automatic backlight. n Diagnostic testing to isolate faulty components for repair. Noise filter rejects up to 3 mA noise for effective operation in electrically noisy environments. High altitude operation up to 3000 m while maintaining CATIV 600 V rating. Rotary switch operation for easy, intuitive field use. Field replaceable battery. What is the IEEE Standard 43-2000? In March 2000, the IEEE-SA Standards Board approved a revision of IEEE Std 43-1974 by the Electric Machinery Committee of the IEEE Power Engineering Society. This revision is IEEE Std 43-2000, the "IEEE Recommended Practice for Testing Insulation Resistance of Rotating Machinery." Following is a brief summary of its highlights: n Test voltages up to 10 kV are recommended for windings rated greater than 12 kV. n Both the insulation resistance and the polarization index test are recommended. With its higher voltage testing capability, the MIT1025 is the perfect everyday work tool for manufacturers, users and maintainers of rotating machinery. Designed in accordance with the requirements of IEEE43:2000, the MIT1025 is ideal for measuring the insulation resistance of armature and field windings in rotating machines rated 1hp (750 W) or greater. The standard applies to synchronous, induction and dc machines as well as synchronous condensers. n Test results should be compared to historical values to identify changes. n In lieu of historical records, minimum acceptable values (based on the type of equipment) for both tests are indicated. n Depending on the machine rating, the readings for one or both tests should exceed the minimum acceptable values. n If the readings are below the minimum acceptable values, the winding is not recommended for an overvoltage test or for operation. MIT515, MIT525, MIT1025 5-kV and 10-kV dc Insulation Resistance Testers SPECIFICATIONS Guard Terminal 2% error guarding 500 k leakage with 100 m load Insulation Range, Analog 100 kW to 10 TW Voltage Input Range 85 to 265 V, 50/60 Hz, 60 VA Insulation Range, Digital MIT515 & MIT525: 10 kW to 10 TW MIT1025: 10 kW to 20 TW Battery Type Lithium-ion, 11.1 V, 5.2 A hour, meets IEC 62133:2003 Test Voltages MIT515 & MIT525: 250 V, 500 V, 1000 V, 2500 V, and 5000 V MIT1025: 500 V, 1000 V, 2500 V, 5000 V, and 10,000 V User Defined Test Voltages MIT515 & MIT525: 100 V to 1 kV in 10 V steps, 1 kV to 5 kV in 25 V steps MIT1025: Same as above plus 5 kV to 10 kV in 25 V steps Battery Life MIT515 & MIT525: Typical capacity 6 hours continuous at 5 kV with a 100 MW load MIT1025: Typical capacity 4.5 hours continuous at 10 kV with a 100 MW load Battery Charge Time 2.5 hours from deep discharge, 2 hours normal discharge 30 min. quick charge: 1 hour operation at 5 kV, 100 MW Accuracy (23 C) MIT515 & MIT525: 5% to 1 T, 20% to 10 T MIT1025: 5% to 2 T, 20% to 20 T Safety Meets the requirements of IEC61010-1 CAT IV 600 V Default voltmeter warns operator of applied voltage above 50 V Voltage Output Accuracy (0C to 30C) +4% -0% 10 V of nominal test voltage at 1 GW load EMC Meets the requirements of IEC61326-1 Voltmeter Range 30 to 660 V ac or dc, 50/60 Hz Accuracy: 3% 3 V Frequency range: 45 Hz to 65 Hz Ingress Protection IP65 (lid closed); IP40 (lid open) Short Circuit Current 3 mA nominal, max. power on all loads outperforming many 5 mA testers Insulation Alarm 100 k to 1 G Current Measurement Range: 0.01 nA to 6 mA Accuracy: 5% 0.2 nA at all voltages Capacitance Range (above 500 V) 10 nF to 25 F (dependent on measurement voltage) Accuracy (23C): 10% 5 nF Temperature Range Operating: -4F to +122F (-20C to +50C) Storage: -13F to +149F (-25C to +65C) Humidity Range 90% RH @ 104F (40C) Altitude 3000 m, CAT rating maintained >2000 m* (*test load connected) Dimensions 12 in. x 11 in. x 7 in. (315 mm x 285 mm x 181 mm) Weight 10 lb. (4.5 kg) Capacitor Charge MIT515 & MIT525: <3 s per F at 3 mA to 5 kV MIT1025: <5 s per F at 3 mA to 10 kV Capacitor Discharge MIT515 & MIT525: <250 ms/F to discharge from 5000 V to 50 V MIT1025: <500 ms/F to discharge from 10,000 V to 50 V Timer Range Up to 99 minutes, 15 seconds minimum setting Memory Capacity 5-1/2 hours continuous logging every 5 s. or 33 logged PI tests or 350 logged IR tests Industry-Standard Tests MIT515: IR, IR(t), DAR, PI MIT525 & MIT1025: IR, IR(t), DAR, PI, SV, DD, Ramp Test Interface USB type B (device) Real Time Output USB, 1 reading/second (voltage, current and resistance) Interference Rejection MIT515 & MIT525: 1 mA per 250 V up to a maximum of 3 mA MIT1025: 1 mA per 600 V up to a maximum of 3 mA Fig. 1: Quality insulation testers exhibit fast voltage rise times to resistance levels commensurate with minimum acceptable values, and maintain selected voltage throughout the remaining measurement range. Below an acceptable level of resistance, rapid voltage drop protects the test item from exposure to high voltage, so that it may be reclaimed by appropriate maintenance. MIT515, MIT525, MIT1025 5-kV and 10-kV dc Insulation Resistance Testers Product comparison guide. A look at each instrument's features. Model Number Display Power Supply MIT515-US MIT525-US MIT1025-US Analog/Digital n n n Line power n n n Rechargable n n n 10.0 kV Test Voltage n 5.0 kV n n n 2.5 kV n n n 1.0 kV n n n 500 V n n n 250 V n n 10 V steps 50 V to 1 kV 25 V steps 1 kV to max. test voltage n n 10 V steps 100 V to 2.5 kV, 25 V steps 2.5 kV to max. test voltage Measurements Test Types n Max. reading 10 T 10 T 20 T Min. reading 10 k 10 k 10 k Voltage n n n Capacitance and time constant n n n Leakage current n n n Auto IR n n n Auto PI n n n Auto SV n n Auto DD n n n n n n Auto DAR n Ramp test Other Features CAT IV 600 V safety rating n n n Timer control n n n Timer display n n n 3mA test currents n n n USB output (cable included) n n RS232 output (cable included) n n Calibration certificate included n n n IP65 rating n n n Alarm limit mode n n n n n n n Temp. recording (manual entry) n n Real time clock n n 2.5 2.5 2.5 Noise rejection 3mA 3mA 3mA Guard terminal performance 2% error guarding 500 k leakage with a 100 M load Compatible with PowerDB User programmable lock voltage range Battery charge time (hours) n MIT515, MIT525, MIT1025 5-kV and 10-kV dc Insulation Resistance Testers Model MIT1025 Panel MIT515, MIT525, MIT1025 5-kV and 10-kV dc Insulation Resistance Testers These unique features improve insulation testing efficiency and effectiveness Large backlit LCD shows multiple parameters simultaneously. ORDERING INFORMATION Item (Qty) Cat. No. MIT515-US 1001-936 MIT525-US 1001-940 MIT1025-US 1001-944 Included Accessories User guide CD Power lead 10 ft (3 m) leadset x 3, medium insulated clips 1002-531 10 ft (3 m) 3 m leadset x 3, large insulated clips (MIT1025 only) 1002-534 CATIV 600V rating on ALL terminals. Included Accessories (MIT525, MIT1025) USB cable 25970-041 PowerDB Lite software Optional Accessories Rotary switch operation for intuitive field use. CB101, 5 kV Calibration Box 6311-077 Calibration Certificate - CB101 1000-113 10 ft (3 m) Control circuit test leads 6220-822 33 ft (10 m) x 3, medium insulated clips 1000-441 50 ft (15 m) x 3, medium insulated clips 1000-442 33 ft (10 m) x 3, large insulated clips 1000-443 50 ft (15 m) x 3, large insulated clips 1000-432 10 ft (3 m) leadset x 3, bare clps 8101-181 26 ft (8 m) leadset x 3, bare clips 8101-182 50 ft (15 m) leadset x 3, bare clips 8101-183 50 ft (15 m) 5 kV screened uninsulated small clips 6311-080 High quality flexible silicon insulated test leads with test clips meet IEC 61010. (Large clips shown.) 10 ft (3 m) 10 kV screened uninsulated small clips 6220-834 33 ft (10 m) 10 kV screened uninsulated small clips 6220-861 50 ft (15 m) 10 kV screened uninsulated small clips 6220-833 Easy-to-read rotary test selection button includes IR, IR(t), DAR, PI, DD, SV and Ramp Test. UK Archcliffe Road, Dover CT17 9EN England T +44 (0) 1 304 502101 F +44 (0) 1 304 207342 UKsales@megger.com UNITED STATES 2621 Van Buren Avenue Norristown, PA 19403 USA T 1 866-254-0962 (USA only) T +1 610-676-8500 F +1 610-676-8625 VFCustomerSupport@megger.com (case sensitive email address) OTHER TECHNICAL SALES OFFICES Dallas USA, College Station USA, Sydney AUSTRALIA, Taby SWEDEN, Ontario CANADA, Trappes FRANCE, Oberursel GERMANY, Aargau SWITZERLAND, Dubai UAE, Mumbai INDIA, Johannesburg SOUTH AFRICA, and Chonburi THAILAND ISO STATEMENT Registered to ISO 9001:2000 Reg no. Q 09250 Registered to ISO 14001 Reg no. EMS 61597 MIT515_525_1025_DS_US_V02 www.megger.com Megger is a registered trademark Information contained herein is subject to change withot notice